{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3608538","name":"Stiner #1 Mine","status":"Abandoned","status_date":"2015-12-11","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Clearfield","nearest_town":"Shawville","operator_id":"P19895","operator_name":"P & N Coal Company Inc","controller_id":"C02001","controller_name":"Prushnok Coal Company Inc","district":"M2","office":"Clearfield PA Field Office","employees":0,"latitude":41.066667,"longitude":-78.366667},"coverage":{"contributingSources":11,"registeredSources":20,"sourceRows":214},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608538","name":"Stiner #1 Mine"},"operator":{"type":"operator","id":"P19895","name":"P & N Coal Company Inc"},"controller":{"type":"controller","id":"C02001","name":"Prushnok Coal Company Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02001","name":"Prushnok Coal Company Inc"},"object":{"type":"mine","id":"3608538","name":"Stiner #1 Mine"},"validFrom":"1987-07-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608538|C02001|1987-07-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19895","name":"P & N Coal Company Inc"},"object":{"type":"mine","id":"3608538","name":"Stiner #1 Mine"},"validFrom":"1995-12-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608538|P19895|1995-12-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02001","name":"Prushnok Coal Company Inc"},"object":{"type":"operator","id":"P19895","name":"P & N Coal Company Inc"},"validFrom":"1995-12-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608538","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608538|P19895|1995-12-01|C02001|1987-07-01|57112"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2006-09-14","lastDate":"2008-10-23","metrics":{"daysLost":0,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"226402","DOCUMENT_NO":"220083080036","ACCIDENT_DT":"10/23/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While using a cutting torch he burnt his left hand.","sourceDate":"2008-10-23"},{"SOURCE_ROW_NUMBER":"19940","DOCUMENT_NO":"220081050044","ACCIDENT_DT":"03/10/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Slipped and fell on snow covered ice as he was working on coal crusher and bumped his head and right elbow.","sourceDate":"2008-03-10"},{"SOURCE_ROW_NUMBER":"71467","DOCUMENT_NO":"220062750071","ACCIDENT_DT":"09/14/2006","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While traveling to work in company truck along Rt. 153 near Penfield the vehicle hydroplaned on substance (mud/water/oil) on road resulting in the truck flipping over.","sourceDate":"2006-09-14"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2015-12-11","lastDate":"2015-12-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":15,"firstDate":"2002-03-05","lastDate":"2012-11-08","metrics":{"ss":4,"delinquent":15,"recentRows":0,"paidPenalty":1444,"proposedPenalty":1444,"currentAssessment":1444},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"686265","VIOLATION_NO":"7041602","ISSUE_DT":"11/08/2012","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-08"},{"SOURCE_ROW_NUMBER":"1669793","VIOLATION_NO":"7040040","ISSUE_DT":"06/20/2011","CFR_STANDARD_CD":"77.1103(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-06-20"},{"SOURCE_ROW_NUMBER":"1669792","VIOLATION_NO":"7040039","ISSUE_DT":"06/20/2011","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-06-20"},{"SOURCE_ROW_NUMBER":"691301","VIOLATION_NO":"7039735","ISSUE_DT":"08/09/2010","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-08-09"},{"SOURCE_ROW_NUMBER":"1671713","VIOLATION_NO":"7039228","ISSUE_DT":"01/12/2010","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-01-12"},{"SOURCE_ROW_NUMBER":"1671712","VIOLATION_NO":"7039227","ISSUE_DT":"01/12/2010","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-01-12"},{"SOURCE_ROW_NUMBER":"1669628","VIOLATION_NO":"7038471","ISSUE_DT":"01/29/2009","CFR_STANDARD_CD":"77.1707(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-29"},{"SOURCE_ROW_NUMBER":"658668","VIOLATION_NO":"7037851","ISSUE_DT":"01/15/2008","CFR_STANDARD_CD":"77.400(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-01-15"},{"SOURCE_ROW_NUMBER":"688227","VIOLATION_NO":"7046468","ISSUE_DT":"05/09/2005","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-09"},{"SOURCE_ROW_NUMBER":"700978","VIOLATION_NO":"7035916","ISSUE_DT":"01/06/2003","CFR_STANDARD_CD":"77.700","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-06"},{"SOURCE_ROW_NUMBER":"700977","VIOLATION_NO":"7035915","ISSUE_DT":"01/06/2003","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-01-06"},{"SOURCE_ROW_NUMBER":"700979","VIOLATION_NO":"7046354","ISSUE_DT":"10/17/2002","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"259.00","CURRENT_ASSESSMENT_AMT":"259.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-10-17"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":43,"firstDate":"2002-07-25","lastDate":"2015-06-16","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":43,"maxConcentration":0.378,"concentrationTotal":4.701},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"870843","CASS_NUM":"58198341","SMP_TAKEN_DT":"6/16/2015","CONC":".04","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-06-16"},{"SOURCE_ROW_NUMBER":"1325061","CASS_NUM":"58129707","SMP_TAKEN_DT":"12/10/2014","CONC":".182","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-10"},{"SOURCE_ROW_NUMBER":"826544","CASS_NUM":"58129718","SMP_TAKEN_DT":"12/10/2014","CONC":".083","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WEIGHMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-10"},{"SOURCE_ROW_NUMBER":"302155","CASS_NUM":"58129701","SMP_TAKEN_DT":"12/10/2014","CONC":".022","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-12-10"},{"SOURCE_ROW_NUMBER":"1644985","CASS_NUM":"58140101","SMP_TAKEN_DT":"4/3/2014","CONC":".346","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-03"},{"SOURCE_ROW_NUMBER":"495541","CASS_NUM":"58139981","SMP_TAKEN_DT":"4/3/2014","CONC":".04","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WEIGHMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-03"},{"SOURCE_ROW_NUMBER":"229928","CASS_NUM":"58140110","SMP_TAKEN_DT":"4/3/2014","CONC":".152","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-03"},{"SOURCE_ROW_NUMBER":"1546275","CASS_NUM":"58135522","SMP_TAKEN_DT":"11/14/2013","CONC":".031","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-14"},{"SOURCE_ROW_NUMBER":"1342291","CASS_NUM":"58135557","SMP_TAKEN_DT":"11/14/2013","CONC":".053","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WEIGHMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-14"},{"SOURCE_ROW_NUMBER":"87798","CASS_NUM":"58135612","SMP_TAKEN_DT":"11/14/2013","CONC":".215","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-11-14"},{"SOURCE_ROW_NUMBER":"1160205","CASS_NUM":"58106426","SMP_TAKEN_DT":"4/3/2013","CONC":".047","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-03"},{"SOURCE_ROW_NUMBER":"170693","CASS_NUM":"58106439","SMP_TAKEN_DT":"4/3/2013","CONC":".073","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WEIGHMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-03"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1995-12-01","lastDate":"1995-12-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":38,"firstDate":"2002-03-05","lastDate":"2015-06-15","metrics":{"inspectors":40,"recentRows":0,"onSiteHours":397,"inspectionHours":540.75,"inspectionSamples":53},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"403990","EVENT_NO":"6249025","INSPECTION_BEGIN_DT":"06/15/2015","INSPECTION_END_DT":"06/17/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"31.5","SUM_TOTAL_ON_SITE_HOURS":"21","sourceDate":"2015-06-15"},{"SOURCE_ROW_NUMBER":"481558","EVENT_NO":"6249017","INSPECTION_BEGIN_DT":"12/08/2014","INSPECTION_END_DT":"12/23/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"21.5","sourceDate":"2014-12-08"},{"SOURCE_ROW_NUMBER":"380523","EVENT_NO":"6248991","INSPECTION_BEGIN_DT":"04/02/2014","INSPECTION_END_DT":"04/10/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"15.75","sourceDate":"2014-04-02"},{"SOURCE_ROW_NUMBER":"708698","EVENT_NO":"6248978","INSPECTION_BEGIN_DT":"11/12/2013","INSPECTION_END_DT":"11/20/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2013-11-12"},{"SOURCE_ROW_NUMBER":"906053","EVENT_NO":"4036352","INSPECTION_BEGIN_DT":"04/02/2013","INSPECTION_END_DT":"04/15/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2013-04-02"},{"SOURCE_ROW_NUMBER":"586307","EVENT_NO":"4036343","INSPECTION_BEGIN_DT":"11/01/2012","INSPECTION_END_DT":"11/14/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"19.25","sourceDate":"2012-11-01"},{"SOURCE_ROW_NUMBER":"65252","EVENT_NO":"6248887","INSPECTION_BEGIN_DT":"06/28/2012","INSPECTION_END_DT":"07/05/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2012-06-28"},{"SOURCE_ROW_NUMBER":"828730","EVENT_NO":"6248869","INSPECTION_BEGIN_DT":"02/16/2012","INSPECTION_END_DT":"02/21/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20.5","SUM_TOTAL_ON_SITE_HOURS":"15.75","sourceDate":"2012-02-16"},{"SOURCE_ROW_NUMBER":"1253","EVENT_NO":"6248135","INSPECTION_BEGIN_DT":"06/20/2011","INSPECTION_END_DT":"06/21/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"20.25","sourceDate":"2011-06-20"},{"SOURCE_ROW_NUMBER":"473862","EVENT_NO":"6248774","INSPECTION_BEGIN_DT":"01/03/2011","INSPECTION_END_DT":"01/18/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2011-01-03"},{"SOURCE_ROW_NUMBER":"492540","EVENT_NO":"4041870","INSPECTION_BEGIN_DT":"08/02/2010","INSPECTION_END_DT":"08/09/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.25","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2010-08-02"},{"SOURCE_ROW_NUMBER":"92017","EVENT_NO":"6248757","INSPECTION_BEGIN_DT":"01/12/2010","INSPECTION_END_DT":"01/27/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.25","SUM_TOTAL_ON_SITE_HOURS":"16.25","sourceDate":"2010-01-12"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":56,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015-Q4":{"hours":451,"employees":1,"production":0},"2015-Q3":{"hours":636,"employees":1,"production":0},"2015-Q2":{"hours":1232,"employees":2,"production":0},"2015-Q1":{"hours":1116,"employees":2,"production":0},"2014-Q4":{"hours":1969,"employees":3,"production":0},"2014-Q3":{"hours":2216,"employees":3,"production":0},"2014-Q2":{"hours":2029,"employees":3,"production":0},"2014-Q1":{"hours":2057,"employees":3,"production":0},"2013-Q4":{"hours":1436,"employees":2,"production":0},"2013-Q3":{"hours":1695,"employees":3,"production":0},"2013-Q2":{"hours":1957,"employees":3,"production":0},"2013-Q1":{"hours":1390,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":5696,"employees":2,"production":0},"2007":{"hours":4584,"employees":2,"production":0},"2008":{"hours":3526,"employees":2,"production":0},"2009":{"hours":3471,"employees":1,"production":0},"2010":{"hours":4525,"employees":2,"production":0},"2011":{"hours":5193,"employees":2,"production":0},"2012":{"hours":5213,"employees":2,"production":0},"2013":{"hours":6478,"employees":3,"production":0},"2014":{"hours":8271,"employees":3,"production":0},"2015":{"hours":3435,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":27,"firstDate":"2002-07-25","lastDate":"2014-12-10","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":559,"pelDoseTotal":285},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"159325","EVENT_NO":"6249017","SURVEY_DATE":"12/10/2014","OCCUPATION_CD_DESC":"WEIGHMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2014-12-10"},{"SOURCE_ROW_NUMBER":"159324","EVENT_NO":"6249017","SURVEY_DATE":"12/10/2014","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"31","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2014-12-10"},{"SOURCE_ROW_NUMBER":"159323","EVENT_NO":"6249017","SURVEY_DATE":"12/10/2014","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"58","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2014-12-10"},{"SOURCE_ROW_NUMBER":"159322","EVENT_NO":"6248978","SURVEY_DATE":"11/14/2013","OCCUPATION_CD_DESC":"WEIGHMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2013-11-14"},{"SOURCE_ROW_NUMBER":"159321","EVENT_NO":"6248978","SURVEY_DATE":"11/14/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"29","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2013-11-14"},{"SOURCE_ROW_NUMBER":"159320","EVENT_NO":"6248978","SURVEY_DATE":"11/14/2013","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"38","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2013-11-14"},{"SOURCE_ROW_NUMBER":"159302","EVENT_NO":"4036343","SURVEY_DATE":"11/13/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"20","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2012-11-13"},{"SOURCE_ROW_NUMBER":"159301","EVENT_NO":"4036343","SURVEY_DATE":"11/13/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"27","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2012-11-13"},{"SOURCE_ROW_NUMBER":"159319","EVENT_NO":"6248869","SURVEY_DATE":"02/17/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"063","ACT_DOSE_85":"17","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2012-02-17"},{"SOURCE_ROW_NUMBER":"159318","EVENT_NO":"6248869","SURVEY_DATE":"02/17/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"16","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2012-02-17"},{"SOURCE_ROW_NUMBER":"159317","EVENT_NO":"6248774","SURVEY_DATE":"01/05/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"21","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2011-01-05"},{"SOURCE_ROW_NUMBER":"159316","EVENT_NO":"6248774","SURVEY_DATE":"01/05/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"18","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2011-01-05"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":15,"firstDate":"2002-03-05","lastDate":"2012-11-08","metrics":{"ss":4,"amountDue":1444,"contested":0,"amountPaid":1444,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":1444},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1943012","VIOLATION_NO":"7041602","VIOLATION_ISSUE_DT":"11/08/2012","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/08/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-11-08"},{"SOURCE_ROW_NUMBER":"1943006","VIOLATION_NO":"7040040","VIOLATION_ISSUE_DT":"06/20/2011","SIG_SUB":"N","PART_SECTION":"77.1103(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-06-20"},{"SOURCE_ROW_NUMBER":"1943005","VIOLATION_NO":"7040039","VIOLATION_ISSUE_DT":"06/20/2011","SIG_SUB":"Y","PART_SECTION":"77.205(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/20/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-06-20"},{"SOURCE_ROW_NUMBER":"1943008","VIOLATION_NO":"7039735","VIOLATION_ISSUE_DT":"08/09/2010","SIG_SUB":"N","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/09/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-08-09"},{"SOURCE_ROW_NUMBER":"1943000","VIOLATION_NO":"7039228","VIOLATION_ISSUE_DT":"01/12/2010","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/12/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-01-12"},{"SOURCE_ROW_NUMBER":"1942999","VIOLATION_NO":"7039227","VIOLATION_ISSUE_DT":"01/12/2010","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/12/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-01-12"},{"SOURCE_ROW_NUMBER":"1943001","VIOLATION_NO":"7038471","VIOLATION_ISSUE_DT":"01/29/2009","SIG_SUB":"N","PART_SECTION":"77.1707(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/02/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-01-29"},{"SOURCE_ROW_NUMBER":"1942998","VIOLATION_NO":"7037851","VIOLATION_ISSUE_DT":"01/15/2008","SIG_SUB":"Y","PART_SECTION":"77.400(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/16/2008","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2008-01-15"},{"SOURCE_ROW_NUMBER":"1943004","VIOLATION_NO":"7046468","VIOLATION_ISSUE_DT":"05/09/2005","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/17/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-05-09"},{"SOURCE_ROW_NUMBER":"1943010","VIOLATION_NO":"7035916","VIOLATION_ISSUE_DT":"01/06/2003","SIG_SUB":"N","PART_SECTION":"77.700","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-01-06"},{"SOURCE_ROW_NUMBER":"1943009","VIOLATION_NO":"7035915","VIOLATION_ISSUE_DT":"01/06/2003","SIG_SUB":"N","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/07/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-01-06"},{"SOURCE_ROW_NUMBER":"1943011","VIOLATION_NO":"7046354","VIOLATION_ISSUE_DT":"10/17/2002","SIG_SUB":"Y","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/18/2002","PROPOSED_PENALTY":"259","AMOUNT_DUE":"259","AMOUNT_PAID":"259","CONTESTED_IND":"N","sourceDate":"2002-10-17"}]}],"safety":{"href":"/api/v1/mines/3608538/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608538/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","heading":"First aid equipment; location; minimum requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1707","part":"77","subchapter":"O","subpart":"R","id":"77.1707","citation":"30 CFR 77.1707","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic sheaths, armors, and conduits enclosing power conductors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.700","part":"77","subchapter":"O","subpart":"H","id":"77.700","citation":"30 CFR 77.700","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608538","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}