{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3608288","name":"Lenig Tunnel","status":"Abandoned and Sealed","status_date":"2008-09-11","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Anthracite)","state":"PA","county":"Northumberland","nearest_town":"Trevorton","operator_id":"P24427","operator_name":"L Coal Company","controller_id":"C07809","controller_name":"James  Lenig","district":"M2","office":"Frackville PA Field Office","employees":0,"latitude":40.756111,"longitude":-76.683055},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":533},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"operator":{"type":"operator","id":"P24427","name":"L Coal Company"},"controller":{"type":"controller","id":"C07809","name":"James  Lenig"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21999","name":"West Cameron Mining"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"1991-10-01","validTo":"1999-01-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P21999|1991-10-01|1999-01-07"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07809","name":"James  Lenig"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"1991-10-01","validTo":"1999-01-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|C07809|1991-10-01|1999-01-07"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07809","name":"James  Lenig"},"object":{"type":"operator","id":"P21999","name":"West Cameron Mining"},"validFrom":"1991-10-01","validTo":"1999-01-07","current":false,"derived":true,"evidenceMineId":"3608288","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P21999|1991-10-01|C07809|1991-10-01|75760"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24049","name":"K Town Mining"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"1999-01-08","validTo":"1999-12-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P24049|1999-01-08|1999-12-22"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15771","name":"Kenneth  Rothermel et al"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"1999-01-08","validTo":"1999-12-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|C15771|1999-01-08|1999-12-22"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15771","name":"Kenneth  Rothermel et al"},"object":{"type":"operator","id":"P24049","name":"K Town Mining"},"validFrom":"1999-01-08","validTo":"1999-12-22","current":false,"derived":true,"evidenceMineId":"3608288","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P24049|1999-01-08|C15771|1999-01-08|96727"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24384","name":"H & R Coal Company"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"1999-12-23","validTo":"2000-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P24384|1999-12-23|2000-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15919","name":"Sharp Walter & Randy Boyer"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"1999-12-23","validTo":"2000-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|C15919|1999-12-23|2000-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15919","name":"Sharp Walter & Randy Boyer"},"object":{"type":"operator","id":"P24384","name":"H & R Coal Company"},"validFrom":"1999-12-23","validTo":"2000-05-31","current":false,"derived":true,"evidenceMineId":"3608288","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P24384|1999-12-23|C15919|1999-12-23|97614"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24427","name":"L Coal Company"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"2000-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P24427|2000-06-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07809","name":"James  Lenig"},"object":{"type":"mine","id":"3608288","name":"Lenig Tunnel"},"validFrom":"2000-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|C07809|2000-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07809","name":"James  Lenig"},"object":{"type":"operator","id":"P24427","name":"L Coal Company"},"validFrom":"2000-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3608288","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3608288|P24427|2000-06-01|C07809|2000-06-01|75762"}}],"coverage":{"historyRecords":4,"edgeCount":12,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2008-09-11","lastDate":"2008-09-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":53,"firstDate":"2000-05-09","lastDate":"2004-05-11","metrics":{"ss":14,"delinquent":53,"recentRows":0,"paidPenalty":2229.69,"proposedPenalty":3896,"currentAssessment":3184},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"657114","VIOLATION_NO":"7006595","ISSUE_DT":"05/11/2004","CFR_STANDARD_CD":"75.1100-2(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-05-11"},{"SOURCE_ROW_NUMBER":"657113","VIOLATION_NO":"7006594","ISSUE_DT":"05/11/2004","CFR_STANDARD_CD":"75.1713-7(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-05-11"},{"SOURCE_ROW_NUMBER":"657112","VIOLATION_NO":"7005958","ISSUE_DT":"05/11/2004","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-05-11"},{"SOURCE_ROW_NUMBER":"656821","VIOLATION_NO":"7005765","ISSUE_DT":"02/23/2004","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"656976","VIOLATION_NO":"7005618","ISSUE_DT":"11/22/2003","CFR_STANDARD_CD":"75.1100-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-11-22"},{"SOURCE_ROW_NUMBER":"656975","VIOLATION_NO":"7005617","ISSUE_DT":"11/20/2003","CFR_STANDARD_CD":"75.332(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-11-20"},{"SOURCE_ROW_NUMBER":"656858","VIOLATION_NO":"7004809","ISSUE_DT":"07/02/2003","CFR_STANDARD_CD":"75.334(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"30.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-02"},{"SOURCE_ROW_NUMBER":"656857","VIOLATION_NO":"7004808","ISSUE_DT":"07/02/2003","CFR_STANDARD_CD":"75.360(b)(5)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"30.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-02"},{"SOURCE_ROW_NUMBER":"656856","VIOLATION_NO":"7004807","ISSUE_DT":"07/02/2003","CFR_STANDARD_CD":"75.381(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"30.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-02"},{"SOURCE_ROW_NUMBER":"656855","VIOLATION_NO":"7004806","ISSUE_DT":"07/02/2003","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"75.00","CURRENT_ASSESSMENT_AMT":"37.50","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-02"},{"SOURCE_ROW_NUMBER":"656854","VIOLATION_NO":"7004805","ISSUE_DT":"07/02/2003","CFR_STANDARD_CD":"75.381(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"235.00","CURRENT_ASSESSMENT_AMT":"117.50","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-02"},{"SOURCE_ROW_NUMBER":"656853","VIOLATION_NO":"7004804","ISSUE_DT":"07/02/2003","CFR_STANDARD_CD":"75.364(a)(2)(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"30.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-02"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":25,"firstDate":"2001-01-31","lastDate":"2004-02-24","metrics":{"appeals":0,"decisions":25,"recentRows":0,"decisionPenalty":1171,"originalPenalty":1883},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"181866","VIOLATION_NO":"7004805","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"235.00","DECISION_PENALTY_AMT":"117.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"181865","VIOLATION_NO":"7004804","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"181666","VIOLATION_NO":"7004807","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"181596","VIOLATION_NO":"7004574","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"79.00","DECISION_PENALTY_AMT":"39.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"751","VIOLATION_NO":"7004809","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"750","VIOLATION_NO":"7004808","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"749","VIOLATION_NO":"7004806","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"75.00","DECISION_PENALTY_AMT":"37.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"643","VIOLATION_NO":"7004803","DOCKET_NO":"PENN 2004-37","DECISION_DT":"02/24/2004","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"75.00","DECISION_PENALTY_AMT":"37.50","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-02-24"},{"SOURCE_ROW_NUMBER":"478705","VIOLATION_NO":"7004572","DOCKET_NO":"PENN 2003-140","DECISION_DT":"10/03/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2003-10-03"},{"SOURCE_ROW_NUMBER":"478704","VIOLATION_NO":"7004569","DOCKET_NO":"PENN 2003-140","DECISION_DT":"10/03/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"66.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2003-10-03"},{"SOURCE_ROW_NUMBER":"478703","VIOLATION_NO":"7004564","DOCKET_NO":"PENN 2003-140","DECISION_DT":"10/03/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2003-10-03"},{"SOURCE_ROW_NUMBER":"477473","VIOLATION_NO":"7004568","DOCKET_NO":"PENN 2003-140","DECISION_DT":"10/03/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55.00","DECISION_PENALTY_AMT":"30.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2003-10-03"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":204,"firstDate":"2000-02-03","lastDate":"2004-06-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":196,"maxConcentration":13.783,"concentrationTotal":115.468},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1429128","CASS_NUM":"57484967","SMP_TAKEN_DT":"6/14/2004","CONC":".251","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-14"},{"SOURCE_ROW_NUMBER":"664565","CASS_NUM":"57485006","SMP_TAKEN_DT":"6/14/2004","CONC":".465","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-14"},{"SOURCE_ROW_NUMBER":"548466","CASS_NUM":"50729730","SMP_TAKEN_DT":"6/9/2004","CONC":".341","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-09"},{"SOURCE_ROW_NUMBER":"1241191","CASS_NUM":"57485007","SMP_TAKEN_DT":"6/8/2004","CONC":".06","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER/BLACKSMITH","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-08"},{"SOURCE_ROW_NUMBER":"641073","CASS_NUM":"50729756","SMP_TAKEN_DT":"6/7/2004","CONC":".294","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-07"},{"SOURCE_ROW_NUMBER":"1203582","CASS_NUM":"50729736","SMP_TAKEN_DT":"6/4/2004","CONC":".492","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-04"},{"SOURCE_ROW_NUMBER":"220690","CASS_NUM":"50729737","SMP_TAKEN_DT":"6/3/2004","CONC":".346","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-03"},{"SOURCE_ROW_NUMBER":"483657","CASS_NUM":"50729727","SMP_TAKEN_DT":"6/2/2004","CONC":".432","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-06-02"},{"SOURCE_ROW_NUMBER":"1598771","CASS_NUM":"57485048","SMP_TAKEN_DT":"5/18/2004","CONC":".151","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"1374101","CASS_NUM":"57484956","SMP_TAKEN_DT":"5/18/2004","CONC":".076","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"201845","CASS_NUM":"57485041","SMP_TAKEN_DT":"5/18/2004","CONC":".153","SMP_TYPE_CD_DESC":"NONDESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOTORMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-05-18"},{"SOURCE_ROW_NUMBER":"1499662","CASS_NUM":"50724809","SMP_TAKEN_DT":"3/26/2004","CONC":".468","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-03-26"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":10,"firstDate":"2002-05-07","lastDate":"2003-08-05","metrics":{"linkedIssuances":10},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1991-10-01","lastDate":"2000-06-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":114,"firstDate":"2000-01-10","lastDate":"2010-07-21","metrics":{"inspectors":123,"recentRows":0,"onSiteHours":908.75,"inspectionHours":1390.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"159681","EVENT_NO":"4306755","INSPECTION_BEGIN_DT":"07/21/2010","INSPECTION_END_DT":"07/21/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2010-07-21"},{"SOURCE_ROW_NUMBER":"553893","EVENT_NO":"4302618","INSPECTION_BEGIN_DT":"07/21/2005","INSPECTION_END_DT":"07/21/2005","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2005-07-21"},{"SOURCE_ROW_NUMBER":"294428","EVENT_NO":"4302602","INSPECTION_BEGIN_DT":"06/17/2005","INSPECTION_END_DT":"06/17/2005","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2005-06-17"},{"SOURCE_ROW_NUMBER":"853347","EVENT_NO":"4301592","INSPECTION_BEGIN_DT":"04/21/2005","INSPECTION_END_DT":"04/22/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2005-04-21"},{"SOURCE_ROW_NUMBER":"41538","EVENT_NO":"4301712","INSPECTION_BEGIN_DT":"01/26/2005","INSPECTION_END_DT":"01/26/2005","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2005-01-26"},{"SOURCE_ROW_NUMBER":"1154743","EVENT_NO":"4301505","INSPECTION_BEGIN_DT":"01/19/2005","INSPECTION_END_DT":"01/19/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-01-19"},{"SOURCE_ROW_NUMBER":"18906","EVENT_NO":"4301495","INSPECTION_BEGIN_DT":"01/19/2005","INSPECTION_END_DT":"01/19/2005","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-01-19"},{"SOURCE_ROW_NUMBER":"1138974","EVENT_NO":"4300882","INSPECTION_BEGIN_DT":"10/28/2004","INSPECTION_END_DT":"10/28/2004","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2004-10-28"},{"SOURCE_ROW_NUMBER":"387942","EVENT_NO":"4010149","INSPECTION_BEGIN_DT":"10/15/2004","INSPECTION_END_DT":"10/25/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2004-10-15"},{"SOURCE_ROW_NUMBER":"925849","EVENT_NO":"4300864","INSPECTION_BEGIN_DT":"09/23/2004","INSPECTION_END_DT":"09/23/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2004-09-23"},{"SOURCE_ROW_NUMBER":"748145","EVENT_NO":"4300861","INSPECTION_BEGIN_DT":"08/17/2004","INSPECTION_END_DT":"08/17/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-08-17"},{"SOURCE_ROW_NUMBER":"357365","EVENT_NO":"4300853","INSPECTION_BEGIN_DT":"07/15/2004","INSPECTION_END_DT":"07/15/2004","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2004-07-15"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":35,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005-Q2":{"hours":0,"employees":0,"production":0},"2005-Q1":{"hours":0,"employees":0,"production":0},"2004-Q4":{"hours":0,"employees":0,"production":0},"2004-Q3":{"hours":1880,"employees":3,"production":728},"2004-Q2":{"hours":2560,"employees":4,"production":860},"2004-Q1":{"hours":2220,"employees":4,"production":917},"2003-Q4":{"hours":1494,"employees":4,"production":494},"2003-Q3":{"hours":2360,"employees":5,"production":634},"2003-Q2":{"hours":1712,"employees":4,"production":586},"2003-Q1":{"hours":1920,"employees":4,"production":743},"2002-Q4":{"hours":1988,"employees":4,"production":720},"2002-Q3":{"hours":520,"employees":5,"production":144}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":1510,"employees":3,"production":834},"2001":{"hours":4416,"employees":4,"production":1614},"2002":{"hours":5106,"employees":4,"production":1669},"2003":{"hours":7486,"employees":4,"production":2457},"2004":{"hours":6660,"employees":4,"production":2505}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2000-05-11","lastDate":"2004-02-19","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":655,"pelDoseTotal":529},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"156637","EVENT_NO":"4010048","SURVEY_DATE":"02/19/2004","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"7","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"156636","EVENT_NO":"4010048","SURVEY_DATE":"02/19/2004","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"77","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"156635","EVENT_NO":"4010048","SURVEY_DATE":"02/19/2004","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"27","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2004-02-19"},{"SOURCE_ROW_NUMBER":"156634","EVENT_NO":"4008175","SURVEY_DATE":"11/06/2002","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"76","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2002-11-06"},{"SOURCE_ROW_NUMBER":"156633","EVENT_NO":"4008175","SURVEY_DATE":"11/06/2002","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2002-11-06"},{"SOURCE_ROW_NUMBER":"156632","EVENT_NO":"4008175","SURVEY_DATE":"11/06/2002","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"23","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2002-11-06"},{"SOURCE_ROW_NUMBER":"156631","EVENT_NO":"4008175","SURVEY_DATE":"11/06/2002","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"25","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2002-11-06"},{"SOURCE_ROW_NUMBER":"156630","EVENT_NO":"4006593","SURVEY_DATE":"11/07/2001","OCCUPATION_CD_DESC":"SCALPER-SCREEN OPERATOR","MACHINE_CD":"34","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"156629","EVENT_NO":"4006593","SURVEY_DATE":"11/07/2001","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"23","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"156628","EVENT_NO":"4006593","SURVEY_DATE":"11/07/2001","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"119","ACT_DOSE_85":"75","PEL_DOSE_90":"61","SURVEY_TYPE":"I","sourceDate":"2001-11-07"},{"SOURCE_ROW_NUMBER":"156627","EVENT_NO":"4005274","SURVEY_DATE":"12/20/2000","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"25","MANUFACTURER_CD":"120","ACT_DOSE_85":"78","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2000-12-20"},{"SOURCE_ROW_NUMBER":"156626","EVENT_NO":"4005274","SURVEY_DATE":"12/20/2000","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"41","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2000-12-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":6,"firstDate":"2000-10-25","lastDate":"2003-11-24","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":12.2,"validSamples":5,"quartzPctTotal":28.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"93207","CASSETTE_NO":"57451960","SAMPLE_DT":"11/24/2003","QUARTZ_PCT":"12.2","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-11-24"},{"SOURCE_ROW_NUMBER":"2546","CASSETTE_NO":"57388920","SAMPLE_DT":"07/17/2002","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-07-17"},{"SOURCE_ROW_NUMBER":"13675","CASSETTE_NO":"57373559","SAMPLE_DT":"08/08/2001","QUARTZ_PCT":"01.3","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-08-08"},{"SOURCE_ROW_NUMBER":"1716","CASSETTE_NO":"50580252","SAMPLE_DT":"04/10/2001","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-04-10"},{"SOURCE_ROW_NUMBER":"140040","CASSETTE_NO":"50574058","SAMPLE_DT":"03/13/2001","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-13"},{"SOURCE_ROW_NUMBER":"68409","CASSETTE_NO":"57287124","SAMPLE_DT":"10/25/2000","QUARTZ_PCT":"10.6","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":58,"firstDate":"2000-05-09","lastDate":"2004-05-11","metrics":{"ss":14,"amountDue":3184,"contested":25,"amountPaid":2229.69,"recentRows":0,"section104d":0,"unterminated":3,"proposedPenalty":3896},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1937633","VIOLATION_NO":"7006595","VIOLATION_ISSUE_DT":"05/11/2004","SIG_SUB":"Y","PART_SECTION":"75.1100-2(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2004","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-05-11"},{"SOURCE_ROW_NUMBER":"1937632","VIOLATION_NO":"7006594","VIOLATION_ISSUE_DT":"05/11/2004","SIG_SUB":"N","PART_SECTION":"75.1713-7(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-05-11"},{"SOURCE_ROW_NUMBER":"1937631","VIOLATION_NO":"7005958","VIOLATION_ISSUE_DT":"05/11/2004","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2004","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-05-11"},{"SOURCE_ROW_NUMBER":"1937614","VIOLATION_NO":"7005765","VIOLATION_ISSUE_DT":"02/23/2004","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/23/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"1937665","VIOLATION_NO":"7005618","VIOLATION_ISSUE_DT":"11/22/2003","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/22/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-11-22"},{"SOURCE_ROW_NUMBER":"1937664","VIOLATION_NO":"7005617","VIOLATION_ISSUE_DT":"11/20/2003","SIG_SUB":"N","PART_SECTION":"75.332(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/17/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2003-11-20"},{"SOURCE_ROW_NUMBER":"1937663","VIOLATION_NO":"7005616","VIOLATION_ISSUE_DT":"11/20/2003","PART_SECTION":"75.334(b)(2)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"11/22/2003","CONTESTED_IND":"N","sourceDate":"2003-11-20"},{"SOURCE_ROW_NUMBER":"1937651","VIOLATION_NO":"7005407","VIOLATION_ISSUE_DT":"09/15/2003","PART_SECTION":"75.1403-6(a)(1)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"11/22/2003","CONTESTED_IND":"N","sourceDate":"2003-09-15"},{"SOURCE_ROW_NUMBER":"1937650","VIOLATION_NO":"7005406","VIOLATION_ISSUE_DT":"09/15/2003","PART_SECTION":"75.1403-6(a)(2)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"11/22/2003","CONTESTED_IND":"N","sourceDate":"2003-09-15"},{"SOURCE_ROW_NUMBER":"1937649","VIOLATION_NO":"7004811","VIOLATION_ISSUE_DT":"07/07/2003","PART_SECTION":"75.381(b)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"09/15/2003","CONTESTED_IND":"N","sourceDate":"2003-07-07"},{"SOURCE_ROW_NUMBER":"1937648","VIOLATION_NO":"7004810","VIOLATION_ISSUE_DT":"07/07/2003","PART_SECTION":"75.333(e)(2)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"09/15/2003","CONTESTED_IND":"N","sourceDate":"2003-07-07"},{"SOURCE_ROW_NUMBER":"1937647","VIOLATION_NO":"7004809","VIOLATION_ISSUE_DT":"07/02/2003","SIG_SUB":"N","PART_SECTION":"75.334(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/15/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"30","AMOUNT_PAID":"30","CONTESTED_IND":"Y","DOCKET_NO":"PENN 2004-37","sourceDate":"2003-07-02"}]}],"safety":{"href":"/api/v1/mines/3608288/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3608288/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":2},{"chapter":"I","heading":"First-aid equipment; location; minimum requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1713-7","part":"75","subchapter":"O","subpart":"R","id":"75.1713-7","citation":"30 CFR 75.1713-7","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","heading":"Working sections and working places.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.332","part":"75","subchapter":"O","subpart":"D","id":"75.332","citation":"30 CFR 75.332","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Worked-out areas and areas where pillars are being recovered.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.334","part":"75","subchapter":"O","subpart":"D","id":"75.334","citation":"30 CFR 75.334","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-6","heading":"Criteria—Self-propelled personnel carriers.","id":"75.1403-6","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-6","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Each self-propelled personnel carrier should:\n\n(1) Be provided with an audible warning device;\n\n(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;\n\n(3) Be provided with reflectors on both ends and sides.\n\n(b) In addition, each track-mounted self-propelled personnel carrier should:\n\n(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;\n\n(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;\n\n(3) Be equipped with properly installed and well-maintained sanding devices, except that personnel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;\n\n(4) If an open type, be equipped with guards of sufficient strength and height to prevent personnel from being thrown from such carriers.","occurrenceCount":2},{"chapter":"I","heading":"Escapeways; anthracite mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.381","part":"75","subchapter":"O","subpart":"D","id":"75.381","citation":"30 CFR 75.381","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3608288","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}