{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3607205","name":"Bell #1","status":"Abandoned","status_date":"2018-07-20","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Clearfield","nearest_town":"Ashland","operator_id":"P12333","operator_name":"Forcey Coal Inc","controller_id":"C06313","controller_name":"David  Forcey; Lynn  Forcey","district":"M2","office":"Clearfield PA Field Office","employees":0,"latitude":41.058333,"longitude":-78.275},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2354},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3607205","name":"Bell #1"},"operator":{"type":"operator","id":"P12333","name":"Forcey Coal Inc"},"controller":{"type":"controller","id":"C06313","name":"David  Forcey; Lynn  Forcey"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P12333","name":"Forcey Coal Inc"},"object":{"type":"mine","id":"3607205","name":"Bell #1"},"validFrom":"1981-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3607205|P12333|1981-09-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C06313","name":"David  Forcey et al"},"object":{"type":"mine","id":"3607205","name":"Bell #1"},"validFrom":"1981-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3607205|C06313|1981-09-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06313","name":"David  Forcey et al"},"object":{"type":"operator","id":"P12333","name":"Forcey Coal Inc"},"validFrom":"1981-09-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3607205","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3607205|P12333|1981-09-01|C06313|1981-09-01|71450"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C06313","name":"Lynn  Forcey et al"},"object":{"type":"operator","id":"P12333","name":"Forcey Coal Inc"},"validFrom":"1981-09-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3607205","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3607205|P12333|1981-09-01|C06313|1981-09-01|71451"}}],"coverage":{"historyRecords":2,"edgeCount":4,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":14,"firstDate":"2000-10-18","lastDate":"2014-02-27","metrics":{"daysLost":238,"injuries":14,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"80109","DOCUMENT_NO":"220140690002","ACCIDENT_DT":"02/27/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee bent over to pick up truck tire and felt pop in left shoulder. Muscle in upper arm became tight. Black and blue appeared on upper arm March 1st.","sourceDate":"2014-02-27"},{"SOURCE_ROW_NUMBER":"148973","DOCUMENT_NO":"220112620055","ACCIDENT_DT":"09/08/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"The operator was cleaning his windows when he slipped and fell. He injured his left leg and foot.","sourceDate":"2011-09-08"},{"SOURCE_ROW_NUMBER":"24228","DOCUMENT_NO":"220112550057","ACCIDENT_DT":"08/30/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Operator was standing on track of dozer when his foot slipped and twisted his right foot - hair line fracture.","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"109990","DOCUMENT_NO":"220112200053","ACCIDENT_DT":"06/10/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"15","NARRATIVE":"Employee was picking up a piece of metal when he heard a popping sound. Accident or incident happened on 6/10/11 didn't miss any work until 8/1/11. 8/1/11 was when employee was off for surgery. Doctor stated this didn't just happen on 6/10/11 had been over a period of time.","sourceDate":"2011-06-10"},{"SOURCE_ROW_NUMBER":"6998","DOCUMENT_NO":"220110240052","ACCIDENT_DT":"01/14/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"46","NARRATIVE":"Operator was helping welder when he slipped off of the counterweight to the ground landing on his hip.The operator was standing on a piece of metal while the welder heated it up at the other end. The snow on the EE's feet became slippery and the operator fell due to the material on his feet. The fall was 53\" from the counter weight to the ground.","sourceDate":"2011-01-14"},{"SOURCE_ROW_NUMBER":"37116","DOCUMENT_NO":"220083110027","ACCIDENT_DT":"10/21/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"The EE was getting out of his truck on the job site, when his back gave out and he said his back hurt. The EE stated it felt like he pulled his back. Panel doctors said it was a pulled muscle.","sourceDate":"2008-10-21"},{"SOURCE_ROW_NUMBER":"239307","DOCUMENT_NO":"220082320031","ACCIDENT_DT":"07/28/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"151","NARRATIVE":"The EE had just finished his pre-shift when he was getting off the 990 loader,slipped off top step and fell down 5 steps to the lower level. He hit his left shoulder and backside. It wasn't a lost time accident or reportable until it was determined on 8/8/08 that he had torn ligaments in his left shoulder - determined by panel doctor.","sourceDate":"2008-07-28"},{"SOURCE_ROW_NUMBER":"114388","DOCUMENT_NO":"220070890023","ACCIDENT_DT":"03/15/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"Operator walking across pit floor-slipped & fell on left shoulder. They were going to set up pump in pit. Another EE witnessed fall.","sourceDate":"2007-03-15"},{"SOURCE_ROW_NUMBER":"234975","DOCUMENT_NO":"220070470060","ACCIDENT_DT":"02/07/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Operator walked to his truck, stomped his feet to remove snow from boots. Operator felt a \"pop\" in his left knee and knee swelled.","sourceDate":"2007-02-07"},{"SOURCE_ROW_NUMBER":"161836","DOCUMENT_NO":"220070510117","ACCIDENT_DT":"02/06/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"While fueling bulldozer, operator slipped off track to ground approx 8', landing on left ankle. Operator was pulling on fuel hose prior to slipping.","sourceDate":"2007-02-06"},{"SOURCE_ROW_NUMBER":"135906","DOCUMENT_NO":"220063170094","ACCIDENT_DT":"10/19/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Operator pulled muscle in back while climbing ladder on 990 loader. He worked until 12:00 PM 10/19/06. Went home and returned to work 10/23/06. Re-aggravated injury 10/30/06 - left for Clearfield Hospital.","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"84449","DOCUMENT_NO":"220061670052","ACCIDENT_DT":"06/07/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Operator was making a ditch with loader. Operator got out of loader to adjust the heater valve at rear of loader. While standing on the counterweight, operator slipped and fell 5' to the ground, breaking two ribs on left side.","sourceDate":"2006-06-07"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2018-07-20","lastDate":"2018-07-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":46,"firstDate":"2000-08-09","lastDate":"2011-11-30","metrics":{"ss":23,"delinquent":46,"recentRows":0,"paidPenalty":4663,"proposedPenalty":5145,"currentAssessment":4663},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1671817","VIOLATION_NO":"7034668","ISSUE_DT":"11/30/2011","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"1671816","VIOLATION_NO":"7034667","ISSUE_DT":"11/30/2011","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"1669723","VIOLATION_NO":"7039375","ISSUE_DT":"01/20/2011","CFR_STANDARD_CD":"77.1000","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-01-20"},{"SOURCE_ROW_NUMBER":"1669722","VIOLATION_NO":"7039374","ISSUE_DT":"01/13/2011","CFR_STANDARD_CD":"77.1605(l)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-01-13"},{"SOURCE_ROW_NUMBER":"1670568","VIOLATION_NO":"7039075","ISSUE_DT":"05/18/2010","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"1670537","VIOLATION_NO":"7039042","ISSUE_DT":"12/03/2009","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-03"},{"SOURCE_ROW_NUMBER":"1670836","VIOLATION_NO":"7038694","ISSUE_DT":"04/16/2009","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-04-16"},{"SOURCE_ROW_NUMBER":"659791","VIOLATION_NO":"7038637","ISSUE_DT":"10/22/2008","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-22"},{"SOURCE_ROW_NUMBER":"659790","VIOLATION_NO":"7038636","ISSUE_DT":"10/16/2008","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-16"},{"SOURCE_ROW_NUMBER":"659789","VIOLATION_NO":"7038635","ISSUE_DT":"10/16/2008","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-16"},{"SOURCE_ROW_NUMBER":"659788","VIOLATION_NO":"7038634","ISSUE_DT":"10/15/2008","CFR_STANDARD_CD":"77.1004(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-10-15"},{"SOURCE_ROW_NUMBER":"688262","VIOLATION_NO":"7037972","ISSUE_DT":"05/01/2008","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-05-01"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3,"firstDate":"2009-08-11","lastDate":"2010-01-08","metrics":{"appeals":0,"decisions":3,"recentRows":0,"decisionPenalty":300,"originalPenalty":782},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"27674","VIOLATION_NO":"7010006","DOCKET_NO":"PENN 2008-598","DECISION_DT":"01/08/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-01-08"},{"SOURCE_ROW_NUMBER":"214518","VIOLATION_NO":"7037536","DOCKET_NO":"PENN 2008-345","DECISION_DT":"09/03/2009","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2009-09-03"},{"SOURCE_ROW_NUMBER":"222499","VIOLATION_NO":"7037972","DOCKET_NO":"PENN 2008-494","DECISION_DT":"08/11/2009","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2009-08-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":192,"firstDate":"2000-08-09","lastDate":"2015-05-04","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":2,"validSamples":190,"maxConcentration":0.894,"concentrationTotal":14.317},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"534389","CASS_NUM":"51382805","SMP_TAKEN_DT":"5/4/2015","CONC":".216","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-05-04"},{"SOURCE_ROW_NUMBER":"135668","CASS_NUM":"51382740","SMP_TAKEN_DT":"5/4/2015","CONC":".09","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-05-04"},{"SOURCE_ROW_NUMBER":"1429352","CASS_NUM":"58199611","SMP_TAKEN_DT":"3/27/2015","CONC":".054","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-27"},{"SOURCE_ROW_NUMBER":"1370941","CASS_NUM":"58199647","SMP_TAKEN_DT":"3/27/2015","CONC":".077","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-27"},{"SOURCE_ROW_NUMBER":"572660","CASS_NUM":"58199891","SMP_TAKEN_DT":"3/27/2015","CONC":".024","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-27"},{"SOURCE_ROW_NUMBER":"567598","CASS_NUM":"58199649","SMP_TAKEN_DT":"3/27/2015","CONC":".031","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-27"},{"SOURCE_ROW_NUMBER":"1268970","CASS_NUM":"51372835","SMP_TAKEN_DT":"3/25/2015","CONC":".057","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-25"},{"SOURCE_ROW_NUMBER":"806558","CASS_NUM":"51339797","SMP_TAKEN_DT":"11/5/2014","CONC":".061","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DWP NOT IN PRODUCING STATUS","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-11-05"},{"SOURCE_ROW_NUMBER":"426141","CASS_NUM":"58144853","SMP_TAKEN_DT":"5/21/2014","CONC":".06","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"1647419","CASS_NUM":"57940173","SMP_TAKEN_DT":"2/7/2013","CONC":".051","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-02-07"},{"SOURCE_ROW_NUMBER":"777263","CASS_NUM":"57940166","SMP_TAKEN_DT":"2/7/2013","CONC":".155","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-02-07"},{"SOURCE_ROW_NUMBER":"1589542","CASS_NUM":"57992762","SMP_TAKEN_DT":"9/17/2012","CONC":".012","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-17"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2002-09-24","lastDate":"2008-03-21","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":3,"firstDate":"2007-06-29","lastDate":"2008-05-01","metrics":{"decisions":3,"ssChanged":1,"recentRows":0,"decisionPenalty":300,"proposedPenalty":782},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"8676","CITATION_NO":"7037972","CITATION_ISSUE_DT":"05/01/2008","DOCKET_NO":"PENN 2008-494","DECISION_DT":"08/11/2009","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2008-05-01"},{"SOURCE_ROW_NUMBER":"175579","CITATION_NO":"7010006","CITATION_ISSUE_DT":"01/22/2008","DOCKET_NO":"PENN 2008-598","DECISION_DT":"01/08/2010","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2008-01-22"},{"SOURCE_ROW_NUMBER":"175059","CITATION_NO":"7037536","CITATION_ISSUE_DT":"06/29/2007","DOCKET_NO":"PENN 2008-345","DECISION_DT":"09/03/2009","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2007-06-29"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1379,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":282,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":6,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1981-09-01","lastDate":"1981-09-01","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":74,"firstDate":"2000-08-08","lastDate":"2016-06-28","metrics":{"inspectors":85,"recentRows":0,"onSiteHours":1322.75,"inspectionHours":1857,"inspectionSamples":162},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"825543","EVENT_NO":"4040401","INSPECTION_BEGIN_DT":"06/28/2016","INSPECTION_END_DT":"08/12/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"27.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2016-06-28"},{"SOURCE_ROW_NUMBER":"49478","EVENT_NO":"4040256","INSPECTION_BEGIN_DT":"02/08/2016","INSPECTION_END_DT":"03/30/2016","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.75","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2016-02-08"},{"SOURCE_ROW_NUMBER":"632163","EVENT_NO":"6248336","INSPECTION_BEGIN_DT":"08/03/2015","INSPECTION_END_DT":"08/19/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20.75","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2015-08-03"},{"SOURCE_ROW_NUMBER":"546885","EVENT_NO":"6249023","INSPECTION_BEGIN_DT":"03/25/2015","INSPECTION_END_DT":"03/30/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"15.75","sourceDate":"2015-03-25"},{"SOURCE_ROW_NUMBER":"1003822","EVENT_NO":"4036396","INSPECTION_BEGIN_DT":"05/15/2014","INSPECTION_END_DT":"06/02/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"183375","EVENT_NO":"4036971","INSPECTION_BEGIN_DT":"09/09/2013","INSPECTION_END_DT":"09/09/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2013-09-09"},{"SOURCE_ROW_NUMBER":"39177","EVENT_NO":"4036955","INSPECTION_BEGIN_DT":"01/31/2013","INSPECTION_END_DT":"02/11/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"32","SUM_TOTAL_ON_SITE_HOURS":"21.5","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"498268","EVENT_NO":"4036757","INSPECTION_BEGIN_DT":"09/11/2012","INSPECTION_END_DT":"09/20/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24.75","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"871148","EVENT_NO":"6248818","INSPECTION_BEGIN_DT":"11/07/2011","INSPECTION_END_DT":"12/27/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"82","SUM_TOTAL_ON_SITE_HOURS":"64.5","sourceDate":"2011-11-07"},{"SOURCE_ROW_NUMBER":"50717","EVENT_NO":"6248847","INSPECTION_BEGIN_DT":"05/26/2011","INSPECTION_END_DT":"07/13/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"94.75","SUM_TOTAL_ON_SITE_HOURS":"67.25","sourceDate":"2011-05-26"},{"SOURCE_ROW_NUMBER":"346513","EVENT_NO":"6248120","INSPECTION_BEGIN_DT":"01/03/2011","INSPECTION_END_DT":"03/25/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"133.5","SUM_TOTAL_ON_SITE_HOURS":"102.25","sourceDate":"2011-01-03"},{"SOURCE_ROW_NUMBER":"421950","EVENT_NO":"6248429","INSPECTION_BEGIN_DT":"05/06/2010","INSPECTION_END_DT":"06/02/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"53","SUM_TOTAL_ON_SITE_HOURS":"39.25","sourceDate":"2010-05-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":168,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2016-Q3":{"hours":280,"employees":1,"production":0},"2016-Q2":{"hours":280,"employees":1,"production":0},"2016-Q1":{"hours":288,"employees":1,"production":0},"2015-Q4":{"hours":0,"employees":0,"production":0},"2015-Q3":{"hours":1349,"employees":2,"production":0},"2015-Q2":{"hours":2958,"employees":8,"production":0},"2015-Q1":{"hours":1082,"employees":2,"production":0},"2014-Q4":{"hours":1602,"employees":3,"production":0},"2014-Q3":{"hours":818,"employees":2,"production":1170},"2014-Q2":{"hours":0,"employees":0,"production":0},"2014-Q1":{"hours":10,"employees":1,"production":0},"2013-Q4":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":62546,"employees":23,"production":215402},"2008":{"hours":76787,"employees":28,"production":161495},"2009":{"hours":56886,"employees":24,"production":74006},"2010":{"hours":67479,"employees":28,"production":119839},"2011":{"hours":69067,"employees":27,"production":98258},"2012":{"hours":25560,"employees":15,"production":26812},"2013":{"hours":6365,"employees":9,"production":10081},"2014":{"hours":2430,"employees":3,"production":1170},"2015":{"hours":5389,"employees":6,"production":0},"2016":{"hours":848,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":102,"firstDate":"2002-08-22","lastDate":"2015-03-27","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":3732,"pelDoseTotal":1483},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147449","EVENT_NO":"6249023","SURVEY_DATE":"03/27/2015","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"63","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2015-03-27"},{"SOURCE_ROW_NUMBER":"147452","EVENT_NO":"6249023","SURVEY_DATE":"03/25/2015","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2015-03-25"},{"SOURCE_ROW_NUMBER":"147451","EVENT_NO":"6249023","SURVEY_DATE":"03/25/2015","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"037","ACT_DOSE_85":"15","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2015-03-25"},{"SOURCE_ROW_NUMBER":"147450","EVENT_NO":"6249023","SURVEY_DATE":"03/25/2015","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"037","ACT_DOSE_85":"41","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2015-03-25"},{"SOURCE_ROW_NUMBER":"147356","EVENT_NO":"4036396","SURVEY_DATE":"05/21/2014","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"26","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2014-05-21"},{"SOURCE_ROW_NUMBER":"147448","EVENT_NO":"6248818","SURVEY_DATE":"12/14/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"30","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"147447","EVENT_NO":"6248818","SURVEY_DATE":"12/14/2011","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"41","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"147446","EVENT_NO":"6248818","SURVEY_DATE":"12/14/2011","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"037","ACT_DOSE_85":"23","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"147445","EVENT_NO":"6248818","SURVEY_DATE":"12/14/2011","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"037","ACT_DOSE_85":"19","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"147444","EVENT_NO":"6248818","SURVEY_DATE":"12/14/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"7","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"147443","EVENT_NO":"6248818","SURVEY_DATE":"11/22/2011","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"119","ACT_DOSE_85":"37","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2011-11-22"},{"SOURCE_ROW_NUMBER":"147442","EVENT_NO":"6248818","SURVEY_DATE":"11/22/2011","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"92","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2011-11-22"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":5,"firstDate":"2002-03-25","lastDate":"2005-05-31","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":37,"validSamples":4,"quartzPctTotal":120},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"128801","CASSETTE_NO":"50794041","SAMPLE_DT":"05/31/2005","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2005-05-31"},{"SOURCE_ROW_NUMBER":"46309","CASSETTE_NO":"57549019","SAMPLE_DT":"03/28/2005","QUARTZ_PCT":"28.6","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-03-28"},{"SOURCE_ROW_NUMBER":"73837","CASSETTE_NO":"50648372","SAMPLE_DT":"05/16/2002","QUARTZ_PCT":"37.0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-16"},{"SOURCE_ROW_NUMBER":"116885","CASSETTE_NO":"50648396","SAMPLE_DT":"05/01/2002","QUARTZ_PCT":"33.4","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-01"},{"SOURCE_ROW_NUMBER":"15205","CASSETTE_NO":"57256822","SAMPLE_DT":"03/25/2002","QUARTZ_PCT":"21.0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":47,"firstDate":"2000-08-09","lastDate":"2011-11-30","metrics":{"ss":24,"amountDue":4663,"contested":3,"amountPaid":4663,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":5145},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1905467","VIOLATION_NO":"7034668","VIOLATION_ISSUE_DT":"11/30/2011","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/30/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"1905466","VIOLATION_NO":"7034667","VIOLATION_ISSUE_DT":"11/30/2011","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/30/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-11-30"},{"SOURCE_ROW_NUMBER":"1905426","VIOLATION_NO":"7039375","VIOLATION_ISSUE_DT":"01/20/2011","SIG_SUB":"Y","PART_SECTION":"77.1000","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/10/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-01-20"},{"SOURCE_ROW_NUMBER":"1905425","VIOLATION_NO":"7039374","VIOLATION_ISSUE_DT":"01/13/2011","SIG_SUB":"Y","PART_SECTION":"77.1605(l)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/13/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-01-13"},{"SOURCE_ROW_NUMBER":"1905445","VIOLATION_NO":"7039075","VIOLATION_ISSUE_DT":"05/18/2010","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/18/2010","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2010-05-18"},{"SOURCE_ROW_NUMBER":"1905468","VIOLATION_NO":"7039042","VIOLATION_ISSUE_DT":"12/03/2009","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/03/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-03"},{"SOURCE_ROW_NUMBER":"1905442","VIOLATION_NO":"7038694","VIOLATION_ISSUE_DT":"04/16/2009","SIG_SUB":"Y","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/16/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-04-16"},{"SOURCE_ROW_NUMBER":"1905465","VIOLATION_NO":"7038637","VIOLATION_ISSUE_DT":"10/22/2008","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/22/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-22"},{"SOURCE_ROW_NUMBER":"1905464","VIOLATION_NO":"7038636","VIOLATION_ISSUE_DT":"10/16/2008","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/18/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-16"},{"SOURCE_ROW_NUMBER":"1905463","VIOLATION_NO":"7038635","VIOLATION_ISSUE_DT":"10/16/2008","SIG_SUB":"Y","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/16/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-10-16"},{"SOURCE_ROW_NUMBER":"1905462","VIOLATION_NO":"7038634","VIOLATION_ISSUE_DT":"10/15/2008","SIG_SUB":"Y","PART_SECTION":"77.1004(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/16/2008","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2008-10-15"},{"SOURCE_ROW_NUMBER":"1905444","VIOLATION_NO":"7037972","VIOLATION_ISSUE_DT":"05/01/2008","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/01/2008","PROPOSED_PENALTY":"334","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"Y","DOCKET_NO":"PENN 2008-494","sourceDate":"2008-05-01"}]}],"safety":{"href":"/api/v1/mines/3607205/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3607205/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":3},{"chapter":"I","heading":"Highwalls, pits and spoil banks; plans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-K/section-77.1000","part":"77","subchapter":"O","subpart":"K","id":"77.1000","citation":"30 CFR 77.1000","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","heading":"Ground control; inspection and maintenance; general.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-K/section-77.1004","part":"77","subchapter":"O","subpart":"K","id":"77.1004","citation":"30 CFR 77.1004","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3607205","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}