{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"3606815","name":"Tito Mine White Vein Slope","status":"Abandoned and Sealed","status_date":"2009-11-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Anthracite)","state":"PA","county":"Schuylkill","nearest_town":"Tower City","operator_id":"0073786","operator_name":"Kimmel's Mining Inc","controller_id":"0040883","controller_name":"Scott B  Kimmel","district":"M2","office":"Frackville PA Field Office","employees":0,"latitude":40.594722,"longitude":-76.586666},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":835},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3606815","name":"Tito Mine White Vein Slope"},"operator":{"type":"operator","id":"0073786","name":"Kimmel's Mining Inc"},"controller":{"type":"controller","id":"0040883","name":"Scott B  Kimmel"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P09251","name":"J J G Coal Company"},"object":{"type":"mine","id":"3606815","name":"Tito Mine White Vein Slope"},"validFrom":"1979-04-01","validTo":"1989-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|P09251|1979-04-01|1989-07-25"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07301","name":"Joseph J  Garber"},"object":{"type":"mine","id":"3606815","name":"Tito Mine White Vein Slope"},"validFrom":"1979-04-01","validTo":"1989-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|C07301|1979-04-01|1989-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07301","name":"Joseph J  Garber"},"object":{"type":"operator","id":"P09251","name":"J J G Coal Company"},"validFrom":"1979-04-01","validTo":"1989-07-25","current":false,"derived":true,"evidenceMineId":"3606815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|P09251|1979-04-01|C07301|1979-04-01|74332"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P20549","name":"Tito Coal"},"object":{"type":"mine","id":"3606815","name":"Tito Mine White Vein Slope"},"validFrom":"1989-07-26","validTo":"2008-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|P20549|1989-07-26|2008-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07874","name":"Gregory S  Showers et al"},"object":{"type":"mine","id":"3606815","name":"Tito Mine White Vein Slope"},"validFrom":"1989-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|C07874|1989-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07874","name":"Gregory S  Showers et al"},"object":{"type":"operator","id":"P20549","name":"Tito Coal"},"validFrom":"1989-07-26","validTo":"2008-05-31","current":false,"derived":true,"evidenceMineId":"3606815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|P20549|1989-07-26|C07874|1989-07-26|75910"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0040883","name":"Scott B  Kimmel"},"object":{"type":"mine","id":"3606815","name":"Tito Mine White Vein Slope"},"validFrom":"2006-07-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|0040883|2006-07-18|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0073786","name":"Kimmel's Mining Inc"},"object":{"type":"mine","id":"3606815","name":"Tito Mine White Vein Slope"},"validFrom":"2008-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|0073786|2008-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0040883","name":"Scott B  Kimmel"},"object":{"type":"operator","id":"0073786","name":"Kimmel's Mining Inc"},"validFrom":"2008-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3606815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"3606815|0073786|2008-06-01|0040883|2006-07-18|899"}}],"coverage":{"historyRecords":3,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2004-12-22","lastDate":"2004-12-22","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"37116","DOCUMENT_NO":"220050190025","ACCIDENT_DT":"12/22/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"WHILE MEN WERE BEING TRANSPORTED TO THE SURFACE, THE MINE CAR ENCOUNTERED A PIECE OF FALLEN ROCK CAUSING THE FRONT END TO SHIFT & CONTACT A PIECE OF TIMBER WHICH STALLED THE HOIST & CAUSED HOIST ROPE TO TEAR. SLOPE CAR TRAVELED DOWN SLOPE 80-100 FT, WHERE THE BACK END DERAILED & CAME TO REST AGAINST THE RIB.","sourceDate":"2004-12-22"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-11-25","lastDate":"2009-11-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":90,"firstDate":"2000-02-29","lastDate":"2009-12-07","metrics":{"ss":30,"delinquent":89,"recentRows":0,"paidPenalty":5957,"proposedPenalty":14791,"currentAssessment":5957},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1309764","VIOLATION_NO":"7011560","ISSUE_DT":"12/07/2009","CFR_STANDARD_CD":"70.204(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-07"},{"SOURCE_ROW_NUMBER":"1308728","VIOLATION_NO":"7010749","ISSUE_DT":"06/05/2008","CFR_STANDARD_CD":"41.20","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-06-05"},{"SOURCE_ROW_NUMBER":"1308687","VIOLATION_NO":"7009556","ISSUE_DT":"08/16/2007","CFR_STANDARD_CD":"77.1109(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-16"},{"SOURCE_ROW_NUMBER":"1308959","VIOLATION_NO":"7010051","ISSUE_DT":"08/15/2007","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-15"},{"SOURCE_ROW_NUMBER":"1308958","VIOLATION_NO":"7010050","ISSUE_DT":"08/15/2007","CFR_STANDARD_CD":"75.381(c)(5)(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-15"},{"SOURCE_ROW_NUMBER":"1308957","VIOLATION_NO":"7010045","ISSUE_DT":"07/16/2007","CFR_STANDARD_CD":"75.310(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-16"},{"SOURCE_ROW_NUMBER":"1308956","VIOLATION_NO":"7010044","ISSUE_DT":"07/16/2007","CFR_STANDARD_CD":"75.310(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-16"},{"SOURCE_ROW_NUMBER":"1308104","VIOLATION_NO":"7010043","ISSUE_DT":"06/21/2007","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"1308103","VIOLATION_NO":"7010042","ISSUE_DT":"06/21/2007","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"1307237","VIOLATION_NO":"7009567","ISSUE_DT":"05/25/2007","CFR_STANDARD_CD":"75.381(c)(5)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-25"},{"SOURCE_ROW_NUMBER":"1307236","VIOLATION_NO":"7009566","ISSUE_DT":"05/25/2007","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-25"},{"SOURCE_ROW_NUMBER":"1308399","VIOLATION_NO":"7008983","ISSUE_DT":"03/14/2007","CFR_STANDARD_CD":"70.100(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-14"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":40,"firstDate":"2001-12-19","lastDate":"2008-07-18","metrics":{"appeals":0,"decisions":40,"recentRows":0,"decisionPenalty":2204,"originalPenalty":11105},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"254619","VIOLATION_NO":"7008739","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"254234","VIOLATION_NO":"7008761","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"254184","VIOLATION_NO":"7008740","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"254183","VIOLATION_NO":"7008737","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"253832","VIOLATION_NO":"7008731","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"625.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"12693","VIOLATION_NO":"7008738","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"12692","VIOLATION_NO":"7008736","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"12691","VIOLATION_NO":"7008730","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"12690","VIOLATION_NO":"7008728","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"650.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"12216","VIOLATION_NO":"7008878","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"12215","VIOLATION_NO":"7008735","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1200.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2008-07-18"},{"SOURCE_ROW_NUMBER":"253136","VIOLATION_NO":"7003823","DOCKET_NO":"PENN 2007-43","DECISION_DT":"09/25/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2007-09-25"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":345,"firstDate":"2000-02-21","lastDate":"2007-08-17","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":21,"validSamples":324,"maxConcentration":8.151,"concentrationTotal":111.484},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1479114","CASS_NUM":"50888584","SMP_TAKEN_DT":"8/17/2007","CONC":".036","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-08-17"},{"SOURCE_ROW_NUMBER":"1404084","CASS_NUM":"50888617","SMP_TAKEN_DT":"6/28/2007","CONC":".084","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-28"},{"SOURCE_ROW_NUMBER":"36609","CASS_NUM":"50888663","SMP_TAKEN_DT":"6/21/2007","CONC":".068","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"1608770","CASS_NUM":"50888639","SMP_TAKEN_DT":"6/20/2007","CONC":".064","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-20"},{"SOURCE_ROW_NUMBER":"351011","CASS_NUM":"50888637","SMP_TAKEN_DT":"6/15/2007","CONC":".151","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-15"},{"SOURCE_ROW_NUMBER":"1494589","CASS_NUM":"50888662","SMP_TAKEN_DT":"6/14/2007","CONC":".119","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-14"},{"SOURCE_ROW_NUMBER":"1384928","CASS_NUM":"50888646","SMP_TAKEN_DT":"6/13/2007","CONC":".024","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-13"},{"SOURCE_ROW_NUMBER":"787841","CASS_NUM":"57668231","SMP_TAKEN_DT":"6/7/2007","CONC":".066","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HOIST ENGINEER/OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-07"},{"SOURCE_ROW_NUMBER":"1108172","CASS_NUM":"57668267","SMP_TAKEN_DT":"6/6/2007","CONC":".057","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HAND LOADERS","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-06"},{"SOURCE_ROW_NUMBER":"299370","CASS_NUM":"57668268","SMP_TAKEN_DT":"6/6/2007","CONC":".045","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-06"},{"SOURCE_ROW_NUMBER":"131174","CASS_NUM":"57668277","SMP_TAKEN_DT":"6/6/2007","CONC":".068","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-06"},{"SOURCE_ROW_NUMBER":"3487","CASS_NUM":"57668274","SMP_TAKEN_DT":"6/6/2007","CONC":".043","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":12,"firstDate":"2000-04-03","lastDate":"2007-10-16","metrics":{"linkedIssuances":12},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":39,"firstDate":"2004-12-30","lastDate":"2006-08-04","metrics":{"decisions":39,"ssChanged":1,"recentRows":0,"decisionPenalty":2160,"proposedPenalty":11039},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"170860","CITATION_NO":"7008878","CITATION_ISSUE_DT":"08/04/2006","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","CFR_STANDARD_CODE":"75.372(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"60.00","sourceDate":"2006-08-04"},{"SOURCE_ROW_NUMBER":"341593","CITATION_NO":"7008870","CITATION_ISSUE_DT":"07/03/2006","DOCKET_NO":"PENN 2007-38","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"75.1502(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"107.00","DECISION_PENALTY_AMT":"40.00","sourceDate":"2006-07-03"},{"SOURCE_ROW_NUMBER":"400030","CITATION_NO":"7008433","CITATION_ISSUE_DT":"05/18/2006","DOCKET_NO":"PENN 2007-39","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"77.505","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"30.00","sourceDate":"2006-05-18"},{"SOURCE_ROW_NUMBER":"399163","CITATION_NO":"7008431","CITATION_ISSUE_DT":"05/18/2006","DOCKET_NO":"PENN 2007-38","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"75.518","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"30.00","sourceDate":"2006-05-18"},{"SOURCE_ROW_NUMBER":"2603","CITATION_NO":"7008432","CITATION_ISSUE_DT":"05/18/2006","DOCKET_NO":"PENN 2007-38","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"75.701","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"72.00","DECISION_PENALTY_AMT":"30.00","sourceDate":"2006-05-18"},{"SOURCE_ROW_NUMBER":"228496","CITATION_NO":"7008429","CITATION_ISSUE_DT":"05/16/2006","DOCKET_NO":"PENN 2007-39","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"77.505","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"25.00","sourceDate":"2006-05-16"},{"SOURCE_ROW_NUMBER":"60111","CITATION_NO":"7008430","CITATION_ISSUE_DT":"05/16/2006","DOCKET_NO":"PENN 2007-39","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"77.505","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"40.00","sourceDate":"2006-05-16"},{"SOURCE_ROW_NUMBER":"341839","CITATION_NO":"7008428","CITATION_ISSUE_DT":"05/15/2006","DOCKET_NO":"PENN 2007-39","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"77.505","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"35.00","sourceDate":"2006-05-15"},{"SOURCE_ROW_NUMBER":"285265","CITATION_NO":"7008427","CITATION_ISSUE_DT":"05/15/2006","DOCKET_NO":"PENN 2007-38","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"77.516","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"30.00","sourceDate":"2006-05-15"},{"SOURCE_ROW_NUMBER":"286820","CITATION_NO":"7008762","CITATION_ISSUE_DT":"05/10/2006","DOCKET_NO":"PENN 2007-38","DECISION_DT":"04/26/2007","CFR_STANDARD_CODE":"75.1400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"60.00","DECISION_PENALTY_AMT":"30.00","sourceDate":"2006-05-10"},{"SOURCE_ROW_NUMBER":"286821","CITATION_NO":"7008736","CITATION_ISSUE_DT":"05/04/2006","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2006-05-04"},{"SOURCE_ROW_NUMBER":"286756","CITATION_NO":"7008737","CITATION_ISSUE_DT":"05/04/2006","DOCKET_NO":"PENN 2007-83","DECISION_DT":"07/18/2008","CFR_STANDARD_CODE":"77.400(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"525.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2006-05-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1979-04-01","lastDate":"2008-06-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":127,"firstDate":"2000-01-06","lastDate":"2009-12-07","metrics":{"inspectors":141,"recentRows":0,"onSiteHours":1397.25,"inspectionHours":2479.75,"inspectionSamples":42},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"339227","EVENT_NO":"4305502","INSPECTION_BEGIN_DT":"12/07/2009","INSPECTION_END_DT":"12/07/2009","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2009-12-07"},{"SOURCE_ROW_NUMBER":"374233","EVENT_NO":"4305301","INSPECTION_BEGIN_DT":"06/12/2009","INSPECTION_END_DT":"06/12/2009","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2009-06-12"},{"SOURCE_ROW_NUMBER":"223481","EVENT_NO":"4305217","INSPECTION_BEGIN_DT":"05/12/2009","INSPECTION_END_DT":"05/12/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2009-05-12"},{"SOURCE_ROW_NUMBER":"400287","EVENT_NO":"4304099","INSPECTION_BEGIN_DT":"02/05/2009","INSPECTION_END_DT":"02/05/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2009-02-05"},{"SOURCE_ROW_NUMBER":"661614","EVENT_NO":"4303991","INSPECTION_BEGIN_DT":"10/30/2008","INSPECTION_END_DT":"10/30/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2008-10-30"},{"SOURCE_ROW_NUMBER":"1124232","EVENT_NO":"4303847","INSPECTION_BEGIN_DT":"07/07/2008","INSPECTION_END_DT":"08/29/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2008-07-07"},{"SOURCE_ROW_NUMBER":"856210","EVENT_NO":"4304028","INSPECTION_BEGIN_DT":"06/04/2008","INSPECTION_END_DT":"06/27/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2008-06-04"},{"SOURCE_ROW_NUMBER":"601369","EVENT_NO":"4304101","INSPECTION_BEGIN_DT":"02/05/2008","INSPECTION_END_DT":"02/21/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"397317","EVENT_NO":"4304333","INSPECTION_BEGIN_DT":"10/05/2007","INSPECTION_END_DT":"10/05/2007","ACTIVITY_CODE":"E15","ACTIVITY":"Compliance Follow-up Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2007-10-05"},{"SOURCE_ROW_NUMBER":"1000388","EVENT_NO":"4304002","INSPECTION_BEGIN_DT":"08/14/2007","INSPECTION_END_DT":"09/26/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"37.5","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2007-08-14"},{"SOURCE_ROW_NUMBER":"1099795","EVENT_NO":"4304319","INSPECTION_BEGIN_DT":"07/25/2007","INSPECTION_END_DT":"07/25/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1018558","EVENT_NO":"4304317","INSPECTION_BEGIN_DT":"07/13/2007","INSPECTION_END_DT":"09/27/2007","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"41","SUM_TOTAL_ON_SITE_HOURS":"21","sourceDate":"2007-07-13"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":2730,"employees":6,"production":1096},"2002-Q3":{"hours":2275,"employees":5,"production":1075},"2002-Q2":{"hours":0,"employees":0,"production":0},"2002-Q1":{"hours":0,"employees":0,"production":0},"2001-Q4":{"hours":0,"employees":0,"production":0},"2001-Q3":{"hours":0,"employees":0,"production":0},"2001-Q2":{"hours":0,"employees":0,"production":0},"2001-Q1":{"hours":2730,"employees":6,"production":1289},"2000-Q4":{"hours":2730,"employees":6,"production":2131},"2000-Q3":{"hours":2275,"employees":5,"production":1819},"2000-Q2":{"hours":2275,"employees":5,"production":1750},"2000-Q1":{"hours":3185,"employees":7,"production":2052}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":17,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":10465,"employees":6,"production":7752},"2001":{"hours":2730,"employees":6,"production":1289},"2002":{"hours":5005,"employees":6,"production":2171},"2003":{"hours":10010,"employees":6,"production":4250},"2004":{"hours":9100,"employees":6,"production":4133},"2005":{"hours":7280,"employees":4,"production":4435},"2006":{"hours":9100,"employees":6,"production":3823},"2007":{"hours":4367,"employees":4,"production":1529},"2008":{"hours":208,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":28,"firstDate":"2000-04-18","lastDate":"2007-06-12","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":699,"pelDoseTotal":405},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"146631","EVENT_NO":"4302479","SURVEY_DATE":"06/12/2007","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"093","ACT_DOSE_85":"45","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2007-06-12"},{"SOURCE_ROW_NUMBER":"146630","EVENT_NO":"4302479","SURVEY_DATE":"06/12/2007","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"37","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2007-06-12"},{"SOURCE_ROW_NUMBER":"146629","EVENT_NO":"4302479","SURVEY_DATE":"06/12/2007","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"33","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2007-06-12"},{"SOURCE_ROW_NUMBER":"146628","EVENT_NO":"4302479","SURVEY_DATE":"06/07/2007","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","MANUFACTURER_CD":"120","ACT_DOSE_85":"22","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2007-06-07"},{"SOURCE_ROW_NUMBER":"146632","EVENT_NO":"4303717","SURVEY_DATE":"12/18/2006","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","MANUFACTURER_CD":"120","ACT_DOSE_85":"64","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2006-12-18"},{"SOURCE_ROW_NUMBER":"146620","EVENT_NO":"4301897","SURVEY_DATE":"09/07/2006","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"8","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"146619","EVENT_NO":"4301897","SURVEY_DATE":"09/07/2006","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"45","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"146618","EVENT_NO":"4301897","SURVEY_DATE":"09/07/2006","OCCUPATION_CD_DESC":"LOADING MACHINE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"146617","EVENT_NO":"4301897","SURVEY_DATE":"09/07/2006","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"14","MANUFACTURER_CD":"120","ACT_DOSE_85":"18","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"146624","EVENT_NO":"4302287","SURVEY_DATE":"02/15/2006","OCCUPATION_CD_DESC":"HOIST ENGINEER/OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2006-02-15"},{"SOURCE_ROW_NUMBER":"146627","EVENT_NO":"4302287","SURVEY_DATE":"02/06/2006","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"19","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2006-02-06"},{"SOURCE_ROW_NUMBER":"146626","EVENT_NO":"4302287","SURVEY_DATE":"02/06/2006","OCCUPATION_CD_DESC":"HAND LOADERS","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"5","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2006-02-06"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":5,"firstDate":"2001-01-22","lastDate":"2005-01-31","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":1.7,"validSamples":5,"quartzPctTotal":2.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"73857","CASSETTE_NO":"57484422","SAMPLE_DT":"01/31/2005","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-31"},{"SOURCE_ROW_NUMBER":"60364","CASSETTE_NO":"57388071","SAMPLE_DT":"01/28/2002","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-28"},{"SOURCE_ROW_NUMBER":"150637","CASSETTE_NO":"57373624","SAMPLE_DT":"07/17/2001","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-07-17"},{"SOURCE_ROW_NUMBER":"86928","CASSETTE_NO":"57290863","SAMPLE_DT":"05/10/2001","QUARTZ_PCT":"00.3","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-10"},{"SOURCE_ROW_NUMBER":"31186","CASSETTE_NO":"57300747","SAMPLE_DT":"01/22/2001","QUARTZ_PCT":"00.3","OCC_CODE_DESC":"HAND LOADERS","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":96,"firstDate":"2000-02-29","lastDate":"2009-12-07","metrics":{"ss":30,"amountDue":5957,"contested":38,"amountPaid":5957,"recentRows":0,"section104d":10,"unterminated":3,"proposedPenalty":14791},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1904423","VIOLATION_NO":"7011560","VIOLATION_ISSUE_DT":"12/07/2009","SIG_SUB":"N","PART_SECTION":"70.204(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/07/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-07"},{"SOURCE_ROW_NUMBER":"1904394","VIOLATION_NO":"7010749","VIOLATION_ISSUE_DT":"06/05/2008","SIG_SUB":"N","PART_SECTION":"41.20","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/08/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-06-05"},{"SOURCE_ROW_NUMBER":"1904407","VIOLATION_NO":"7009556","VIOLATION_ISSUE_DT":"08/16/2007","SIG_SUB":"N","PART_SECTION":"77.1109(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-08-16"},{"SOURCE_ROW_NUMBER":"1904403","VIOLATION_NO":"7010051","VIOLATION_ISSUE_DT":"08/15/2007","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-08-15"},{"SOURCE_ROW_NUMBER":"1904402","VIOLATION_NO":"7010050","VIOLATION_ISSUE_DT":"08/15/2007","SIG_SUB":"N","PART_SECTION":"75.381(c)(5)(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/28/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-08-15"},{"SOURCE_ROW_NUMBER":"1904401","VIOLATION_NO":"7010046","VIOLATION_ISSUE_DT":"07/16/2007","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"07/17/2007","CONTESTED_IND":"N","sourceDate":"2007-07-16"},{"SOURCE_ROW_NUMBER":"1904400","VIOLATION_NO":"7010045","VIOLATION_ISSUE_DT":"07/16/2007","SIG_SUB":"N","PART_SECTION":"75.310(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2007-07-16"},{"SOURCE_ROW_NUMBER":"1904399","VIOLATION_NO":"7010044","VIOLATION_ISSUE_DT":"07/16/2007","SIG_SUB":"N","PART_SECTION":"75.310(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2007-07-16"},{"SOURCE_ROW_NUMBER":"1904390","VIOLATION_NO":"7010043","VIOLATION_ISSUE_DT":"06/21/2007","SIG_SUB":"N","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"1904389","VIOLATION_NO":"7010042","VIOLATION_ISSUE_DT":"06/21/2007","SIG_SUB":"N","PART_SECTION":"75.360(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"1904392","VIOLATION_NO":"7009567","VIOLATION_ISSUE_DT":"05/25/2007","SIG_SUB":"Y","PART_SECTION":"75.381(c)(5)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/05/2007","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2007-05-25"},{"SOURCE_ROW_NUMBER":"1904391","VIOLATION_NO":"7009566","VIOLATION_ISSUE_DT":"05/25/2007","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/25/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-05-25"}]}],"safety":{"href":"/api/v1/mines/3606815/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3606815/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Approved sampling devices; maintenance and calibration.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.204","part":"70","subchapter":"O","subpart":"C","id":"70.204","citation":"30 CFR 70.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 41.20","heading":"Legal identity report.","id":"41.20","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-G/part-41/subpart-C/section-41.20","part":"41","partHeading":"PART 41—NOTIFICATION OF LEGAL IDENTITY","subchapter":"G","subchapterHeading":"SUBCHAPTER G—FILING AND OTHER ADMINISTRATIVE REQUIREMENTS","subpart":"C","subpartHeading":"Subpart C—Operator's Report to the Mine Safety and Health Administration","text":"Each operator of a coal or other mine shall file notification of legal identity and every change thereof with the appropriate district manager of the Mine Safety and Health Administration by properly completing, mailing, or otherwise delivering form 2000-7 “legal identity report” which shall be provided by the Mine Safety and Health Administration for this purpose. If additional space is required, the operator may use a separate sheet or sheets.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Escapeways; anthracite mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.381","part":"75","subchapter":"O","subpart":"D","id":"75.381","citation":"30 CFR 75.381","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3606815","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}