{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3605123","name":"Solar No 7","status":"Abandoned and Sealed","status_date":"2002-11-14","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"PA","county":"Somerset","nearest_town":"Hooversville","operator_id":"P21173","operator_name":"Genesis Inc","controller_id":"C14254","controller_name":"John P  Garcia","district":"C03","office":"Indiana PA Field Office","employees":0,"latitude":40.133888,"longitude":-78.983333},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":524},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3605123","name":"Solar No 7"},"operator":{"type":"operator","id":"P21173","name":"Genesis Inc"},"controller":{"type":"controller","id":"C14254","name":"John P  Garcia"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P04874","name":"Lunar Mining Inc"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1975-11-01","validTo":"1981-11-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P04874|1975-11-01|1981-11-22"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00355","name":"George  Ledney"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1975-11-01","validTo":"1981-11-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|C00355|1975-11-01|1981-11-22"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00355","name":"George  Ledney"},"object":{"type":"operator","id":"P04874","name":"Lunar Mining Inc"},"validFrom":"1975-11-01","validTo":"1981-11-22","current":false,"derived":true,"evidenceMineId":"3605123","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P04874|1975-11-01|C00355|1975-11-01|46376"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02729","name":"Gulf + Western Industries Inc"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1976-12-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|C02729|1976-12-17|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P06705","name":"Solar Fuel Company-A Gulf + Western Company"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1981-11-23","validTo":"1986-03-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P06705|1981-11-23|1986-03-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02729","name":"Gulf + Western Industries Inc"},"object":{"type":"operator","id":"P06705","name":"Solar Fuel Company-A Gulf + Western Company"},"validFrom":"1981-11-23","validTo":"1986-03-13","current":false,"derived":true,"evidenceMineId":"3605123","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P06705|1981-11-23|C02729|1976-12-17|60604"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P17546","name":"Solar Fuel Company Inc"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1986-03-14","validTo":"1994-09-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P17546|1986-03-14|1994-09-06"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12311","name":"David C  Klementik  et al"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1986-03-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|C12311|1986-03-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12311","name":"David C  Klementik  et al"},"object":{"type":"operator","id":"P17546","name":"Solar Fuel Company Inc"},"validFrom":"1986-03-14","validTo":"1994-09-06","current":false,"derived":true,"evidenceMineId":"3605123","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P17546|1986-03-14|C12311|1986-03-14|86575"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14254","name":"John P  Garcia et al"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1990-09-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|C14254|1990-09-04|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21173","name":"Genesis Inc"},"object":{"type":"mine","id":"3605123","name":"Solar No 7"},"validFrom":"1994-09-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P21173|1994-09-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14254","name":"John P  Garcia et al"},"object":{"type":"operator","id":"P21173","name":"Genesis Inc"},"validFrom":"1994-09-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"3605123","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3605123|P21173|1994-09-07|C14254|1990-09-04|92339"}}],"coverage":{"historyRecords":4,"edgeCount":12,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":14,"firstDate":"2000-01-26","lastDate":"2001-08-24","metrics":{"daysLost":268,"injuries":12,"fatalities":1,"recentRows":0,"restrictedDays":58,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"32812","DOCUMENT_NO":"220012470015","ACCIDENT_DT":"08/24/2001","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE WAS TRAINING SLOPE BELT USING A HAMMER WITH TAPE AND GROVES CUT IN HANDLE. EMPLOYEE WAS HITTING BOTTOM HANGERS AND HAMMER GOT CAUGHT BETWEEN BELT AND ROLLER, PULLING HAND INTO BELT. E MPLOYEE WAS WEARING A WATCH WHICH CAUSED INJURIES WHEN HE PULLED HAND AND WRIST OUT.","sourceDate":"2001-08-24"},{"SOURCE_ROW_NUMBER":"88629","DOCUMENT_NO":"220011970003","ACCIDENT_DT":"06/27/2001","DEGREE_INJURY":"FATALITY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"WHILE MINING IN THE FIRST LEFT SECTION CROSS CUT 3 TO 4 EMPLOYEE FINISHED THE CUT AND POSITIONED HIMSELF INBY LAST ROW OF BOLTS WHEN LARGE SLAB OF ROOF FELL STRIKING EMPLOYEE CAUSING FATAL INJ URIES.","sourceDate":"2001-06-27"},{"SOURCE_ROW_NUMBER":"109950","DOCUMENT_NO":"220011970026","ACCIDENT_DT":"06/26/2001","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"239","NARRATIVE":"2 MECHANICS WERE CLEANING FIRE SUPPRESSION SPRAYS ON SIDE OF MINER. THEY HAD THEIR MANTRIP PARKED BESIDE MINER AT AN INTERSECTION. ALONG SIDE MANTRIP WAS A CANVAS CHECK-FOREMAN WAS OPERATING S COOP, REMOVING GOB FROM FACE OF #1 ENTRY AND HE DROVE SCOOP THROUGH CHECK LIFTING MANTRIP WITH SCOOP PUSHING MANTRIP INTO LEG OF MECHANIC.","sourceDate":"2001-06-26"},{"SOURCE_ROW_NUMBER":"273593","DOCUMENT_NO":"220010120021","ACCIDENT_DT":"01/06/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"EE WAS REPLACING HEAD JACK ON FLETCHER BOLTER. EE WAS USING A DRILL STEEL AS A PRYBAR. BAR SLIPPED AND EMPLOYEE SMASHED LEFT THUMB.","sourceDate":"2001-01-06"},{"SOURCE_ROW_NUMBER":"170428","DOCUMENT_NO":"220002380017","ACCIDENT_DT":"08/21/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Examiner, Fire boss, Pre-shift examiner, Mine examiner","NO_INJURIES":"1","NARRATIVE":"WHILE HELPING CHANGE 100 HP MOTOR ON BELT DRIVE EMPLOYEE HAD SMALL FINGER OF LEFT HAND PINCHED BETWEEN MOTOR AND FRAME.","sourceDate":"2000-08-21"},{"SOURCE_ROW_NUMBER":"200386","DOCUMENT_NO":"220002240048","ACCIDENT_DT":"08/03/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Miner, NEC","NO_INJURIES":"1","NARRATIVE":"EE WAS HELPING MECHANIC, MECHANIC WAS USING SLEDGE HAMMER TO REMOVE PINS AND PIN FLEW, STRIKING VICTUM IN FOREHEAD.","sourceDate":"2000-08-03"},{"SOURCE_ROW_NUMBER":"37085","DOCUMENT_NO":"220002150027","ACCIDENT_DT":"07/21/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"WHILE LIFTING 6' POST EE PULLED MUSCLE IN RT. SHOULDER.","sourceDate":"2000-07-21"},{"SOURCE_ROW_NUMBER":"101425","DOCUMENT_NO":"220001960020","ACCIDENT_DT":"07/07/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AREA WHERE ROOF FALL OCCURED IS TRANSITION FROM SAWSTONE TO FIRM SLATE AND 42\" ROOF BOLTS WHERE INSTALLED.","sourceDate":"2000-07-07"},{"SOURCE_ROW_NUMBER":"226282","DOCUMENT_NO":"220001360141","ACCIDENT_DT":"05/08/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","NARRATIVE":"WHILE CLEANING ROCK OFF MINER EMPLOYEE HAND SLIPPED AND CUT RIGHT INDEX FINGEER ON ROCK REQUIRING STITCHES.","sourceDate":"2000-05-08"},{"SOURCE_ROW_NUMBER":"234947","DOCUMENT_NO":"220001320025","ACCIDENT_DT":"05/05/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"SLATE ROOF WITH SLICK IN SIDE ABOVE ANCHORAGE ZONE WITH 42\" RESIN BOLTS INSTALLED INT HIS AREA.","sourceDate":"2000-05-05"},{"SOURCE_ROW_NUMBER":"122897","DOCUMENT_NO":"220000940070","ACCIDENT_DT":"03/27/2000","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"EE HAS BEEN WORKING WITH DISCOMFORT AND PAIN HAS INCREASED WHERE DOCTOR'S ATTENTION IS NEEDED.","sourceDate":"2000-03-27"},{"SOURCE_ROW_NUMBER":"75771","DOCUMENT_NO":"220000610008","ACCIDENT_DT":"02/25/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","NARRATIVE":"EE WAS SPREADING CALICUM IN TRACK ENTRY EE SLIPPED ON ICE AND HIT KNEE ON EDGE AT MOTOR MANTRIP.","sourceDate":"2000-02-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2002-11-14","lastDate":"2002-11-14","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":60,"firstDate":"2000-01-13","lastDate":"2001-11-29","metrics":{"ss":31,"delinquent":60,"recentRows":0,"paidPenalty":33515,"proposedPenalty":71015,"currentAssessment":33515},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"681985","VIOLATION_NO":"7051536","ISSUE_DT":"11/29/2001","CFR_STANDARD_CD":"70.101","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"184.00","CURRENT_ASSESSMENT_AMT":"184.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-29"},{"SOURCE_ROW_NUMBER":"681984","VIOLATION_NO":"7051535","ISSUE_DT":"11/29/2001","CFR_STANDARD_CD":"70.101","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"184.00","CURRENT_ASSESSMENT_AMT":"184.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-29"},{"SOURCE_ROW_NUMBER":"681983","VIOLATION_NO":"7051533","ISSUE_DT":"11/01/2001","CFR_STANDARD_CD":"72.630(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-01"},{"SOURCE_ROW_NUMBER":"682926","VIOLATION_NO":"7051293","ISSUE_DT":"09/27/2001","CFR_STANDARD_CD":"75.380(d)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-27"},{"SOURCE_ROW_NUMBER":"682921","VIOLATION_NO":"7046222","ISSUE_DT":"09/27/2001","CFR_STANDARD_CD":"75.383(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-27"},{"SOURCE_ROW_NUMBER":"682920","VIOLATION_NO":"7046221","ISSUE_DT":"09/24/2001","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-24"},{"SOURCE_ROW_NUMBER":"682925","VIOLATION_NO":"7051292","ISSUE_DT":"09/22/2001","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"173.00","CURRENT_ASSESSMENT_AMT":"173.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-22"},{"SOURCE_ROW_NUMBER":"682924","VIOLATION_NO":"7051291","ISSUE_DT":"09/22/2001","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-22"},{"SOURCE_ROW_NUMBER":"682923","VIOLATION_NO":"7051290","ISSUE_DT":"09/21/2001","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-21"},{"SOURCE_ROW_NUMBER":"682922","VIOLATION_NO":"7051289","ISSUE_DT":"09/20/2001","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-20"},{"SOURCE_ROW_NUMBER":"700359","VIOLATION_NO":"7045958","ISSUE_DT":"09/04/2001","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"140.00","CURRENT_ASSESSMENT_AMT":"140.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"700358","VIOLATION_NO":"7045957","ISSUE_DT":"09/04/2001","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-09-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2002-09-16","lastDate":"2002-09-16","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":27500,"originalPenalty":65000},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"478380","VIOLATION_NO":"7045955","DOCKET_NO":"PENN20020124","DECISION_DT":"09/16/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"20000.00","DECISION_PENALTY_AMT":"7500.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2002-09-16"},{"SOURCE_ROW_NUMBER":"178113","VIOLATION_NO":"7045956","DOCKET_NO":"PENN20020124","DECISION_DT":"09/16/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"45000.00","DECISION_PENALTY_AMT":"20000.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2002-09-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":232,"firstDate":"2000-01-03","lastDate":"2002-01-15","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":23,"validSamples":209,"maxConcentration":4.262,"concentrationTotal":225.917},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1467875","CASS_NUM":"57379338","SMP_TAKEN_DT":"1/15/2002","CONC":".919","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"1056013","CASS_NUM":"57379403","SMP_TAKEN_DT":"1/15/2002","CONC":"1.564","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"539468","CASS_NUM":"57379361","SMP_TAKEN_DT":"1/15/2002","CONC":".913","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"366921","CASS_NUM":"57379553","SMP_TAKEN_DT":"1/15/2002","CONC":".151","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"1303401","CASS_NUM":"50625620","SMP_TAKEN_DT":"1/11/2002","CONC":".339","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-11"},{"SOURCE_ROW_NUMBER":"173643","CASS_NUM":"50623953","SMP_TAKEN_DT":"1/10/2002","CONC":".7","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-10"},{"SOURCE_ROW_NUMBER":"879052","CASS_NUM":"50625644","SMP_TAKEN_DT":"1/9/2002","CONC":".71","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-09"},{"SOURCE_ROW_NUMBER":"886564","CASS_NUM":"50623944","SMP_TAKEN_DT":"1/8/2002","CONC":"1.631","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-08"},{"SOURCE_ROW_NUMBER":"1134805","CASS_NUM":"50625598","SMP_TAKEN_DT":"1/7/2002","CONC":".855","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-01-07"},{"SOURCE_ROW_NUMBER":"1389532","CASS_NUM":"50623933","SMP_TAKEN_DT":"12/14/2001","CONC":".843","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-12-14"},{"SOURCE_ROW_NUMBER":"996006","CASS_NUM":"50625630","SMP_TAKEN_DT":"12/13/2001","CONC":"3.294","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-12-13"},{"SOURCE_ROW_NUMBER":"574078","CASS_NUM":"50625662","SMP_TAKEN_DT":"12/13/2001","CONC":"1.438","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2001-12-13"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2000-02-08","lastDate":"2001-10-26","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1975-11-01","lastDate":"1994-09-07","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":57,"firstDate":"2000-01-12","lastDate":"2002-10-08","metrics":{"inspectors":69,"recentRows":0,"onSiteHours":1016.5,"inspectionHours":1773,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"253016","EVENT_NO":"4033352","INSPECTION_BEGIN_DT":"10/08/2002","INSPECTION_END_DT":"11/19/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2002-10-08"},{"SOURCE_ROW_NUMBER":"177358","EVENT_NO":"4031677","INSPECTION_BEGIN_DT":"08/05/2002","INSPECTION_END_DT":"09/18/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"21.5","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2002-08-05"},{"SOURCE_ROW_NUMBER":"203125","EVENT_NO":"4011582","INSPECTION_BEGIN_DT":"05/01/2002","INSPECTION_END_DT":"05/01/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2002-05-01"},{"SOURCE_ROW_NUMBER":"538479","EVENT_NO":"4031665","INSPECTION_BEGIN_DT":"04/09/2002","INSPECTION_END_DT":"06/14/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"45.5","SUM_TOTAL_ON_SITE_HOURS":"29.5","sourceDate":"2002-04-09"},{"SOURCE_ROW_NUMBER":"474382","EVENT_NO":"4032209","INSPECTION_BEGIN_DT":"01/29/2002","INSPECTION_END_DT":"03/25/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"37.75","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2002-01-29"},{"SOURCE_ROW_NUMBER":"1090104","EVENT_NO":"4035055","INSPECTION_BEGIN_DT":"01/16/2002","INSPECTION_END_DT":"01/25/2002","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.25","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2002-01-16"},{"SOURCE_ROW_NUMBER":"721352","EVENT_NO":"4032205","INSPECTION_BEGIN_DT":"01/15/2002","INSPECTION_END_DT":"01/15/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.25","SUM_TOTAL_ON_SITE_HOURS":"8.25","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"25320","EVENT_NO":"4031063","INSPECTION_BEGIN_DT":"01/09/2002","INSPECTION_END_DT":"01/16/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2002-01-09"},{"SOURCE_ROW_NUMBER":"574591","EVENT_NO":"4035013","INSPECTION_BEGIN_DT":"01/04/2002","INSPECTION_END_DT":"01/04/2002","ACTIVITY_CODE":"CEA","ACTIVITY":"ROOF CONTROL TECHNICAL INVESTIGTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2002-01-04"},{"SOURCE_ROW_NUMBER":"123928","EVENT_NO":"4032199","INSPECTION_BEGIN_DT":"12/05/2001","INSPECTION_END_DT":"12/05/2001","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2001-12-05"},{"SOURCE_ROW_NUMBER":"938697","EVENT_NO":"4032196","INSPECTION_BEGIN_DT":"11/14/2001","INSPECTION_END_DT":"11/16/2001","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.25","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2001-11-14"},{"SOURCE_ROW_NUMBER":"495628","EVENT_NO":"4032195","INSPECTION_BEGIN_DT":"10/31/2001","INSPECTION_END_DT":"12/12/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"131.75","SUM_TOTAL_ON_SITE_HOURS":"95.5","sourceDate":"2001-10-31"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":0,"employees":0,"production":0},"2002-Q3":{"hours":0,"employees":0,"production":0},"2002-Q2":{"hours":729,"employees":1,"production":0},"2002-Q1":{"hours":6471,"employees":11,"production":17524},"2001-Q4":{"hours":22263,"employees":40,"production":82948},"2001-Q3":{"hours":18776,"employees":36,"production":80968},"2001-Q2":{"hours":17389,"employees":32,"production":100371},"2001-Q1":{"hours":18041,"employees":31,"production":110175},"2000-Q4":{"hours":17301,"employees":31,"production":100361},"2000-Q3":{"hours":17230,"employees":31,"production":90698},"2000-Q2":{"hours":21524,"employees":35,"production":82753},"2000-Q1":{"hours":22053,"employees":36,"production":86424}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":78108,"employees":33,"production":360236},"2001":{"hours":76469,"employees":35,"production":374462},"2002":{"hours":7200,"employees":9,"production":17524}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":7,"firstDate":"2000-02-15","lastDate":"2000-02-22","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":544,"pelDoseTotal":354},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"143847","EVENT_NO":"4031513","SURVEY_DATE":"02/22/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"106","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2000-02-22"},{"SOURCE_ROW_NUMBER":"143846","EVENT_NO":"4031513","SURVEY_DATE":"02/22/2000","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"98","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2000-02-22"},{"SOURCE_ROW_NUMBER":"143845","EVENT_NO":"4031513","SURVEY_DATE":"02/22/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"60","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2000-02-22"},{"SOURCE_ROW_NUMBER":"143844","EVENT_NO":"4031513","SURVEY_DATE":"02/22/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"98","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2000-02-22"},{"SOURCE_ROW_NUMBER":"143843","EVENT_NO":"4031513","SURVEY_DATE":"02/22/2000","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"88","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2000-02-22"},{"SOURCE_ROW_NUMBER":"143842","EVENT_NO":"4031513","SURVEY_DATE":"02/22/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"79","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2000-02-22"},{"SOURCE_ROW_NUMBER":"143841","EVENT_NO":"4031512","SURVEY_DATE":"02/15/2000","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"15","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2000-02-15"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":49,"firstDate":"2000-02-24","lastDate":"2002-01-15","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":22.1,"validSamples":46,"quartzPctTotal":406.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"6356","CASSETTE_NO":"57379361","SAMPLE_DT":"01/15/2002","QUARTZ_PCT":"02.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"166661","CASSETTE_NO":"50623941","SAMPLE_DT":"12/18/2001","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-18"},{"SOURCE_ROW_NUMBER":"104401","CASSETTE_NO":"50625605","SAMPLE_DT":"12/03/2001","QUARTZ_PCT":"13.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-12-03"},{"SOURCE_ROW_NUMBER":"147928","CASSETTE_NO":"57376703","SAMPLE_DT":"11/14/2001","QUARTZ_PCT":"19.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-14"},{"SOURCE_ROW_NUMBER":"141939","CASSETTE_NO":"57376826","SAMPLE_DT":"11/14/2001","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-14"},{"SOURCE_ROW_NUMBER":"76317","CASSETTE_NO":"57376805","SAMPLE_DT":"11/14/2001","QUARTZ_PCT":"01.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-14"},{"SOURCE_ROW_NUMBER":"117884","CASSETTE_NO":"50598632","SAMPLE_DT":"10/23/2001","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-10-23"},{"SOURCE_ROW_NUMBER":"46325","CASSETTE_NO":"50595422","SAMPLE_DT":"10/10/2001","QUARTZ_PCT":"10.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-10-10"},{"SOURCE_ROW_NUMBER":"139227","CASSETTE_NO":"50595425","SAMPLE_DT":"10/09/2001","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2001-10-09"},{"SOURCE_ROW_NUMBER":"144000","CASSETTE_NO":"57376671","SAMPLE_DT":"09/25/2001","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-09-25"},{"SOURCE_ROW_NUMBER":"128428","CASSETTE_NO":"57376988","SAMPLE_DT":"09/25/2001","QUARTZ_PCT":"15.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-09-25"},{"SOURCE_ROW_NUMBER":"115514","CASSETTE_NO":"57376648","SAMPLE_DT":"09/25/2001","QUARTZ_PCT":"20.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-09-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":61,"firstDate":"2000-01-13","lastDate":"2001-11-29","metrics":{"ss":31,"amountDue":33515,"contested":2,"amountPaid":33515,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":71015},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1893509","VIOLATION_NO":"7051536","VIOLATION_ISSUE_DT":"11/29/2001","SIG_SUB":"Y","PART_SECTION":"70.101","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/27/2002","PROPOSED_PENALTY":"184","AMOUNT_DUE":"184","AMOUNT_PAID":"184","CONTESTED_IND":"N","sourceDate":"2001-11-29"},{"SOURCE_ROW_NUMBER":"1893508","VIOLATION_NO":"7051535","VIOLATION_ISSUE_DT":"11/29/2001","SIG_SUB":"Y","PART_SECTION":"70.101","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/27/2002","PROPOSED_PENALTY":"184","AMOUNT_DUE":"184","AMOUNT_PAID":"184","CONTESTED_IND":"N","sourceDate":"2001-11-29"},{"SOURCE_ROW_NUMBER":"1893507","VIOLATION_NO":"7051533","VIOLATION_ISSUE_DT":"11/01/2001","SIG_SUB":"N","PART_SECTION":"72.630(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/01/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-01"},{"SOURCE_ROW_NUMBER":"1893502","VIOLATION_NO":"7051293","VIOLATION_ISSUE_DT":"09/27/2001","SIG_SUB":"N","PART_SECTION":"75.380(d)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/27/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-27"},{"SOURCE_ROW_NUMBER":"1893497","VIOLATION_NO":"7046222","VIOLATION_ISSUE_DT":"09/27/2001","SIG_SUB":"N","PART_SECTION":"75.383(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/27/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-27"},{"SOURCE_ROW_NUMBER":"1893496","VIOLATION_NO":"7046221","VIOLATION_ISSUE_DT":"09/24/2001","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/24/2001","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2001-09-24"},{"SOURCE_ROW_NUMBER":"1893501","VIOLATION_NO":"7051292","VIOLATION_ISSUE_DT":"09/22/2001","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/22/2001","PROPOSED_PENALTY":"173","AMOUNT_DUE":"173","AMOUNT_PAID":"173","CONTESTED_IND":"N","sourceDate":"2001-09-22"},{"SOURCE_ROW_NUMBER":"1893500","VIOLATION_NO":"7051291","VIOLATION_ISSUE_DT":"09/22/2001","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/22/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-22"},{"SOURCE_ROW_NUMBER":"1893499","VIOLATION_NO":"7051290","VIOLATION_ISSUE_DT":"09/21/2001","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/21/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-21"},{"SOURCE_ROW_NUMBER":"1893498","VIOLATION_NO":"7051289","VIOLATION_ISSUE_DT":"09/20/2001","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/21/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-09-20"},{"SOURCE_ROW_NUMBER":"1893488","VIOLATION_NO":"7045958","VIOLATION_ISSUE_DT":"09/04/2001","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/07/2001","PROPOSED_PENALTY":"140","AMOUNT_DUE":"140","AMOUNT_PAID":"140","CONTESTED_IND":"N","sourceDate":"2001-09-04"},{"SOURCE_ROW_NUMBER":"1893487","VIOLATION_NO":"7045957","VIOLATION_ISSUE_DT":"09/04/2001","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/07/2001","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2001-09-04"}]}],"safety":{"href":"/api/v1/mines/3605123/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3605123/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"[Reserved]","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-B/section-70.101","part":"70","subchapter":"O","subpart":"B","id":"70.101","citation":"30 CFR 70.101","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3605123","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}