{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3401815","name":"Lincoln Power","status":"Abandoned","status_date":"2012-03-07","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"OK","county":"Le Flore","nearest_town":"Heavener","operator_id":"P03500","operator_name":"Farrell-Cooper Mining Company","controller_id":"C00463","controller_name":"William J  Cooper","district":"M5","office":"Little Rock AR Field Office","employees":0,"latitude":34.9,"longitude":-94.516666},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":831},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3401815","name":"Lincoln Power"},"operator":{"type":"operator","id":"P03500","name":"Farrell-Cooper Mining Company"},"controller":{"type":"controller","id":"C00463","name":"William J  Cooper"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00463","name":"William J  Cooper"},"object":{"type":"mine","id":"3401815","name":"Lincoln Power"},"validFrom":"1975-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3401815|C00463|1975-03-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P03500","name":"Farrell-Cooper Mining Company"},"object":{"type":"mine","id":"3401815","name":"Lincoln Power"},"validFrom":"1999-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3401815|P03500|1999-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00463","name":"William J  Cooper"},"object":{"type":"operator","id":"P03500","name":"Farrell-Cooper Mining Company"},"validFrom":"1999-01-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3401815","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3401815|P03500|1999-01-01|C00463|1975-03-01|47358"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":20,"firstDate":"2000-02-01","lastDate":"2006-05-18","metrics":{"daysLost":212,"injuries":17,"fatalities":0,"recentRows":0,"restrictedDays":33,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"140125","DOCUMENT_NO":"220061500029","ACCIDENT_DT":"05/18/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"The injured was trying to roll a rock off the haul road and strained his back.","sourceDate":"2006-05-18"},{"SOURCE_ROW_NUMBER":"118485","DOCUMENT_NO":"220060260030","ACCIDENT_DT":"01/17/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"While hauling overburden, the injured was backing up for the shovel to load him and the shovel bucket hit the bed of his end dump truck, jarring and straining the injured's neck.  He missed one full shift and went home early during another shift.","sourceDate":"2006-01-17"},{"SOURCE_ROW_NUMBER":"36918","DOCUMENT_NO":"220051870041","ACCIDENT_DT":"06/22/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"33","NARRATIVE":"While steam cleaning a piece of equipment, the injured accidently squeezed the trigger of the wand and hit the right side of his right foot. The outside of the foot received 1st and 2nd degree burns.","sourceDate":"2005-06-22"},{"SOURCE_ROW_NUMBER":"32666","DOCUMENT_NO":"220051510081","ACCIDENT_DT":"05/22/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Injured was walking on the ground, tripped and caused pain in his ankle. He did not report the injury until 5/23/2005 and was off only one day 5/24/2005. He worked his regular shift on 5/22, the date of injury, and 5/23/2005.","sourceDate":"2005-05-22"},{"SOURCE_ROW_NUMBER":"19683","DOCUMENT_NO":"220050590061","ACCIDENT_DT":"02/21/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While attempting to cut open an oil filter to check for trash in the filter material, the injured slipped knocking the bottom ring off and hit his thumb on the vice holding the filter. He cut hit thumb on the vice, requiring 7 stitches.","sourceDate":"2005-02-21"},{"SOURCE_ROW_NUMBER":"230468","DOCUMENT_NO":"220043580034","ACCIDENT_DT":"12/20/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"WHILE SEALING THE HIGHWALL WITH THE HOE BUCKET, THE INJURED'S HOE SLIPPED ON THE WALL, JERKING THE OPERATOR & STRAINING HIS BACK.","sourceDate":"2004-12-20"},{"SOURCE_ROW_NUMBER":"264929","DOCUMENT_NO":"220033160026","ACCIDENT_DT":"10/29/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Grader operator, Roadgrader operator","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"REPORTED TO COMPANY AND RECEIVED FIRST TREATMENT BEYOND FIRST AID ON 11-5-03. WHILE RUNNING A WATER WAGON, THE INJURED WAS TURNING IT AROUND, HIT A HOLE AND THE BERM JARRING HIS HIP AND CAUSIN G A STRAIN. RECEIVED A PRESCRIPTION FOR MUSCLE RELAXERS.","sourceDate":"2003-10-29"},{"SOURCE_ROW_NUMBER":"92695","DOCUMENT_NO":"220031820062","ACCIDENT_DT":"06/19/2003","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"OCCUPATIONAL SKIN DISEASES","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"WHILE PERFORMING HIS MECHANIC JOB DUTIES ON EQUIPMENT, THE INJURED CAME INTO CONTACT WITH POISON IVY AND SUFFERED AN ALERGIC REACTION.","sourceDate":"2003-06-19"},{"SOURCE_ROW_NUMBER":"66930","DOCUMENT_NO":"220020770038","ACCIDENT_DT":"03/11/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN EE'S PICKUP SHORTED OUT & CAUGHT FIRE UNDER THE HOOD WHILE PARKED IN THE EE'S PARKING LOT. NO ONE WAS AROUND, BUT A MECHANIC APPROX 300' AWAY WHO HEARD IT WHEN A TIRE BLEW OUT. THE FIRE PRE VENTED THE HOOD FROM BEING OPENED & 4 FIRE EXTINGUISHERS COULD NOT REACH THE BASE & PUT IT OUT. FIRE BURNED LESS THAN 45 MINUTES. NO OTHER DAMAGE OR INJURIES INVOLVED.","sourceDate":"2002-03-11"},{"SOURCE_ROW_NUMBER":"41156","DOCUMENT_NO":"220020560154","ACCIDENT_DT":"02/21/2002","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","NARRATIVE":"WHILE HOOKING UP AN AUGHER FLIGHT WITH HIS LEFT HAND, THE INJURED GRABBED THE FLIGHT WITH HIS RIGHT HAND CONTACTING A SHARP BURR RESULTING IN A CUT REQUIRING 14 SUTURES TO HIS RING FINGER.","sourceDate":"2002-02-21"},{"SOURCE_ROW_NUMBER":"105455","DOCUMENT_NO":"220012640082","ACCIDENT_DT":"09/17/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"IGNITION OR EXPLOSION OF GAS OR DUST","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"WHILE AUGERING HOLE #1054 AT 360' DEEP THE AUGER EITHER INTERSECTED THE PREVIOUS HOLE OR A VOID ALLOWED OXYGEN TO ENTER THE HOLE. A METHANE GAS FIRE WAS TRIGGERED AND BURNED LESS THAN 4 MINUTE S TOTAL AT THE BROW OF THE HOLE. THE FIRE WAS EXTINGUISHED WITH A WATER HOSE AND DILUTION IN THE AIR. THERE WERE NO INJURIES OR EQUIPMENT DAMAGE.","sourceDate":"2001-09-17"},{"SOURCE_ROW_NUMBER":"170265","DOCUMENT_NO":"220012080041","ACCIDENT_DT":"07/25/2001","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"26","NARRATIVE":"WHILE OPERATING THE ELEVATING CONVEYOR, THE INJURED REACHED TO PICK UP A SMALL ROCK TO INSPECT JUST AS A LARGE PIECE OF COAL ROLLED BACK DOWN THE CONVEYOR AND SMASHED HIS HAND AGAINST ONE OF T HE CONVEYOR PADDLES RESULTING IN A TORN LIGAMENT, HAIRLINE FRACTURE AND STITCHES.","sourceDate":"2001-07-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-03-07","lastDate":"2012-03-07","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":81,"firstDate":"2000-01-19","lastDate":"2006-06-07","metrics":{"ss":31,"delinquent":68,"recentRows":0,"paidPenalty":7708,"proposedPenalty":7768,"currentAssessment":7768},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1216377","VIOLATION_NO":"7623328","ISSUE_DT":"06/07/2006","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-07"},{"SOURCE_ROW_NUMBER":"1216255","VIOLATION_NO":"7623487","ISSUE_DT":"12/12/2005","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-12"},{"SOURCE_ROW_NUMBER":"1216254","VIOLATION_NO":"7623486","ISSUE_DT":"12/08/2005","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-08"},{"SOURCE_ROW_NUMBER":"1216253","VIOLATION_NO":"7623485","ISSUE_DT":"12/06/2005","CFR_STANDARD_CD":"48.26(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"178.00","CURRENT_ASSESSMENT_AMT":"178.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"1216252","VIOLATION_NO":"7623484","ISSUE_DT":"12/06/2005","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"1216251","VIOLATION_NO":"7623483","ISSUE_DT":"12/06/2005","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"1216258","VIOLATION_NO":"7623595","ISSUE_DT":"12/05/2005","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1216257","VIOLATION_NO":"7623594","ISSUE_DT":"12/05/2005","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1216256","VIOLATION_NO":"7623593","ISSUE_DT":"12/05/2005","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"154.00","CURRENT_ASSESSMENT_AMT":"154.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1216206","VIOLATION_NO":"7623300","ISSUE_DT":"09/14/2005","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-14"},{"SOURCE_ROW_NUMBER":"1216205","VIOLATION_NO":"7623299","ISSUE_DT":"09/14/2005","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"177.00","CURRENT_ASSESSMENT_AMT":"177.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-14"},{"SOURCE_ROW_NUMBER":"1216204","VIOLATION_NO":"7623298","ISSUE_DT":"09/14/2005","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-14"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2000-03-20","lastDate":"2000-03-20","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":0,"originalPenalty":1000},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"477129","VIOLATION_NO":"4367538","DOCKET_NO":"CENT20000006","DECISION_DT":"03/20/2000","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"1000.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2000-03-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":135,"firstDate":"2000-01-20","lastDate":"2010-10-05","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":7,"validSamples":128,"maxConcentration":1.502,"concentrationTotal":48.775},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147982","CASS_NUM":"57866753","SMP_TAKEN_DT":"10/5/2010","CONC":".592","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-10-05"},{"SOURCE_ROW_NUMBER":"1433722","CASS_NUM":"50844780","SMP_TAKEN_DT":"9/12/2006","CONC":".239","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"833545","CASS_NUM":"50867207","SMP_TAKEN_DT":"8/8/2006","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-08"},{"SOURCE_ROW_NUMBER":"959713","CASS_NUM":"50867146","SMP_TAKEN_DT":"7/20/2006","CONC":".201","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"1172091","CASS_NUM":"57641960","SMP_TAKEN_DT":"6/16/2006","CONC":".201","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WATER TRUCK OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"803501","CASS_NUM":"57641971","SMP_TAKEN_DT":"6/16/2006","CONC":".105","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"330620","CASS_NUM":"57641939","SMP_TAKEN_DT":"6/16/2006","CONC":".396","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"138587","CASS_NUM":"57641948","SMP_TAKEN_DT":"6/16/2006","CONC":".272","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1656271","CASS_NUM":"57617943","SMP_TAKEN_DT":"6/8/2006","CONC":".125","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-08"},{"SOURCE_ROW_NUMBER":"1245247","CASS_NUM":"57617916","SMP_TAKEN_DT":"6/8/2006","CONC":".162","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-08"},{"SOURCE_ROW_NUMBER":"1231166","CASS_NUM":"57617898","SMP_TAKEN_DT":"6/8/2006","CONC":".195","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-08"},{"SOURCE_ROW_NUMBER":"1206446","CASS_NUM":"57617924","SMP_TAKEN_DT":"6/8/2006","CONC":".094","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-08"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":183,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":47,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1999-01-01","lastDate":"1999-01-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":62,"firstDate":"2000-01-19","lastDate":"2012-02-15","metrics":{"inspectors":70,"recentRows":0,"onSiteHours":668.5,"inspectionHours":1314,"inspectionSamples":19},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"445111","EVENT_NO":"4261239","INSPECTION_BEGIN_DT":"02/15/2012","INSPECTION_END_DT":"02/15/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"357132","EVENT_NO":"4261828","INSPECTION_BEGIN_DT":"10/17/2011","INSPECTION_END_DT":"10/31/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2011-10-17"},{"SOURCE_ROW_NUMBER":"21654","EVENT_NO":"4261448","INSPECTION_BEGIN_DT":"04/17/2011","INSPECTION_END_DT":"05/02/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2011-04-17"},{"SOURCE_ROW_NUMBER":"804522","EVENT_NO":"4261444","INSPECTION_BEGIN_DT":"03/31/2011","INSPECTION_END_DT":"03/31/2011","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2011-03-31"},{"SOURCE_ROW_NUMBER":"151867","EVENT_NO":"4261841","INSPECTION_BEGIN_DT":"10/04/2010","INSPECTION_END_DT":"10/05/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20.75","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2010-10-04"},{"SOURCE_ROW_NUMBER":"335597","EVENT_NO":"4261694","INSPECTION_BEGIN_DT":"08/24/2010","INSPECTION_END_DT":"08/25/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2010-08-24"},{"SOURCE_ROW_NUMBER":"45824","EVENT_NO":"4261158","INSPECTION_BEGIN_DT":"08/22/2008","INSPECTION_END_DT":"08/22/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2008-08-22"},{"SOURCE_ROW_NUMBER":"358273","EVENT_NO":"4261155","INSPECTION_BEGIN_DT":"07/02/2008","INSPECTION_END_DT":"07/03/2008","ACTIVITY_CODE":"E25","ACTIVITY":"Part 50 Audit","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2008-07-02"},{"SOURCE_ROW_NUMBER":"595763","EVENT_NO":"4260627","INSPECTION_BEGIN_DT":"12/11/2007","INSPECTION_END_DT":"12/13/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.25","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2007-12-11"},{"SOURCE_ROW_NUMBER":"1142273","EVENT_NO":"4260676","INSPECTION_BEGIN_DT":"09/07/2006","INSPECTION_END_DT":"09/11/2006","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4.25","sourceDate":"2006-09-07"},{"SOURCE_ROW_NUMBER":"630707","EVENT_NO":"4260668","INSPECTION_BEGIN_DT":"08/04/2006","INSPECTION_END_DT":"08/04/2006","ACTIVITY_CODE":"E24","ACTIVITY":"Other Technical Compliance Investigations","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.75","SUM_TOTAL_ON_SITE_HOURS":"4.75","sourceDate":"2006-08-04"},{"SOURCE_ROW_NUMBER":"872581","EVENT_NO":"4260653","INSPECTION_BEGIN_DT":"06/06/2006","INSPECTION_END_DT":"06/20/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"61","SUM_TOTAL_ON_SITE_HOURS":"34.75","sourceDate":"2006-06-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":102,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q3":{"hours":0,"employees":0,"production":0},"2012-Q2":{"hours":0,"employees":0,"production":0},"2012-Q1":{"hours":0,"employees":0,"production":0},"2011-Q4":{"hours":0,"employees":0,"production":0},"2011-Q3":{"hours":0,"employees":0,"production":0},"2011-Q2":{"hours":0,"employees":0,"production":0},"2011-Q1":{"hours":0,"employees":0,"production":0},"2010-Q4":{"hours":0,"employees":0,"production":0},"2010-Q3":{"hours":0,"employees":0,"production":0},"2008-Q3":{"hours":0,"employees":0,"production":0},"2008-Q2":{"hours":0,"employees":0,"production":0},"2008-Q1":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":75450,"employees":28,"production":372231},"2001":{"hours":74971,"employees":28,"production":369770},"2002":{"hours":62874,"employees":24,"production":279865},"2003":{"hours":63689,"employees":24,"production":265958},"2004":{"hours":84600,"employees":28,"production":356161},"2005":{"hours":126421,"employees":44,"production":392215},"2006":{"hours":94383,"employees":30,"production":336979},"2007":{"hours":42418,"employees":19,"production":94675}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":82,"firstDate":"2000-01-19","lastDate":"2010-10-05","metrics":{"recentRows":0,"doseOver100":14,"actDoseTotal":5776,"pelDoseTotal":3678},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"134403","EVENT_NO":"4261841","SURVEY_DATE":"10/05/2010","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"61","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2010-10-05"},{"SOURCE_ROW_NUMBER":"134402","EVENT_NO":"4260653","SURVEY_DATE":"06/16/2006","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"78","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"134401","EVENT_NO":"4260653","SURVEY_DATE":"06/16/2006","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"67","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"134400","EVENT_NO":"4260653","SURVEY_DATE":"06/16/2006","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"34","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"134399","EVENT_NO":"4260653","SURVEY_DATE":"06/16/2006","OCCUPATION_CD_DESC":"WATER TRUCK OPERATOR","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"71","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"134398","EVENT_NO":"4260653","SURVEY_DATE":"06/15/2006","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"71","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2006-06-15"},{"SOURCE_ROW_NUMBER":"134397","EVENT_NO":"4260653","SURVEY_DATE":"06/15/2006","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"52","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2006-06-15"},{"SOURCE_ROW_NUMBER":"134396","EVENT_NO":"4260653","SURVEY_DATE":"06/15/2006","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"57","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2006-06-15"},{"SOURCE_ROW_NUMBER":"134395","EVENT_NO":"4260653","SURVEY_DATE":"06/15/2006","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"79","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2006-06-15"},{"SOURCE_ROW_NUMBER":"134394","EVENT_NO":"4260543","SURVEY_DATE":"12/13/2005","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"119","ACT_DOSE_85":"20","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2005-12-13"},{"SOURCE_ROW_NUMBER":"134393","EVENT_NO":"4260543","SURVEY_DATE":"12/13/2005","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"28","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2005-12-13"},{"SOURCE_ROW_NUMBER":"134392","EVENT_NO":"4260543","SURVEY_DATE":"12/13/2005","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"108","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2005-12-13"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":15,"firstDate":"2000-04-17","lastDate":"2006-08-08","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":18.1,"validSamples":14,"quartzPctTotal":98.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"71493","CASSETTE_NO":"50867207","SAMPLE_DT":"08/08/2006","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2006-08-08"},{"SOURCE_ROW_NUMBER":"151584","CASSETTE_NO":"50867134","SAMPLE_DT":"07/18/2006","QUARTZ_PCT":"14.7","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-07-18"},{"SOURCE_ROW_NUMBER":"69177","CASSETTE_NO":"57641948","SAMPLE_DT":"06/16/2006","QUARTZ_PCT":"18.1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"82377","CASSETTE_NO":"57617829","SAMPLE_DT":"12/13/2005","QUARTZ_PCT":"08.7","OCC_CODE_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-12-13"},{"SOURCE_ROW_NUMBER":"56631","CASSETTE_NO":"57617878","SAMPLE_DT":"12/13/2005","QUARTZ_PCT":"09.7","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-12-13"},{"SOURCE_ROW_NUMBER":"168234","CASSETTE_NO":"57601932","SAMPLE_DT":"06/29/2005","QUARTZ_PCT":"10.2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-06-29"},{"SOURCE_ROW_NUMBER":"94065","CASSETTE_NO":"57601960","SAMPLE_DT":"06/29/2005","QUARTZ_PCT":"09.9","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-06-29"},{"SOURCE_ROW_NUMBER":"129431","CASSETTE_NO":"57504915","SAMPLE_DT":"01/13/2005","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-13"},{"SOURCE_ROW_NUMBER":"118911","CASSETTE_NO":"57482318","SAMPLE_DT":"12/06/2002","QUARTZ_PCT":"00.6","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-12-06"},{"SOURCE_ROW_NUMBER":"17434","CASSETTE_NO":"57425972","SAMPLE_DT":"05/23/2002","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"132945","CASSETTE_NO":"57326696","SAMPLE_DT":"11/05/2001","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-11-05"},{"SOURCE_ROW_NUMBER":"140197","CASSETTE_NO":"57326864","SAMPLE_DT":"06/04/2001","QUARTZ_PCT":"00.2","OCC_CODE_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-04"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":84,"firstDate":"2000-01-19","lastDate":"2006-06-07","metrics":{"ss":31,"amountDue":7768,"contested":0,"amountPaid":7708,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":7768},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1796967","VIOLATION_NO":"7623328","VIOLATION_ISSUE_DT":"06/07/2006","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-07"},{"SOURCE_ROW_NUMBER":"1797004","VIOLATION_NO":"7623487","VIOLATION_ISSUE_DT":"12/12/2005","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/13/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-12"},{"SOURCE_ROW_NUMBER":"1797003","VIOLATION_NO":"7623486","VIOLATION_ISSUE_DT":"12/08/2005","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/13/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-08"},{"SOURCE_ROW_NUMBER":"1797002","VIOLATION_NO":"7623485","VIOLATION_ISSUE_DT":"12/06/2005","SIG_SUB":"N","PART_SECTION":"48.26(b)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2005","PROPOSED_PENALTY":"178","AMOUNT_DUE":"178","AMOUNT_PAID":"178","CONTESTED_IND":"N","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"1797001","VIOLATION_NO":"7623484","VIOLATION_ISSUE_DT":"12/06/2005","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"1797000","VIOLATION_NO":"7623483","VIOLATION_ISSUE_DT":"12/06/2005","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/08/2005","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"N","sourceDate":"2005-12-06"},{"SOURCE_ROW_NUMBER":"1797007","VIOLATION_NO":"7623595","VIOLATION_ISSUE_DT":"12/05/2005","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1797006","VIOLATION_NO":"7623594","VIOLATION_ISSUE_DT":"12/05/2005","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/05/2005","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"N","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1797005","VIOLATION_NO":"7623593","VIOLATION_ISSUE_DT":"12/05/2005","SIG_SUB":"Y","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2005","PROPOSED_PENALTY":"154","AMOUNT_DUE":"154","AMOUNT_PAID":"154","CONTESTED_IND":"N","sourceDate":"2005-12-05"},{"SOURCE_ROW_NUMBER":"1796987","VIOLATION_NO":"7623300","VIOLATION_ISSUE_DT":"09/14/2005","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/15/2005","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2005-09-14"},{"SOURCE_ROW_NUMBER":"1796986","VIOLATION_NO":"7623299","VIOLATION_ISSUE_DT":"09/14/2005","SIG_SUB":"Y","PART_SECTION":"77.205(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/14/2005","PROPOSED_PENALTY":"177","AMOUNT_DUE":"177","AMOUNT_PAID":"177","CONTESTED_IND":"N","sourceDate":"2005-09-14"},{"SOURCE_ROW_NUMBER":"1796985","VIOLATION_NO":"7623298","VIOLATION_ISSUE_DT":"09/14/2005","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/15/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-09-14"}]}],"safety":{"href":"/api/v1/mines/3401815/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3401815/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":2},{"chapter":"I","heading":"Experienced miner training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.26","part":"48","subchapter":"H","subpart":"B","id":"48.26","citation":"30 CFR 48.26","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3401815","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}