{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3304591","name":"Shean Hill Mine","status":"Abandoned","status_date":"2017-12-22","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"OH","county":"Jefferson","nearest_town":"Salineville","operator_id":"P21337","operator_name":"Sterling Mining Corporation","controller_id":"C00082","controller_name":"W Thomas  Mackall","district":"C03","office":"St. Clairsville OH Field Office","employees":0,"latitude":40.625715,"longitude":-80.844114},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":1226},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3304591","name":"Shean Hill Mine"},"operator":{"type":"operator","id":"P21337","name":"Sterling Mining Corporation"},"controller":{"type":"controller","id":"C00082","name":"W Thomas  Mackall"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00082","name":"W Thomas  Mackall et al"},"object":{"type":"mine","id":"3304591","name":"Shean Hill Mine"},"validFrom":"1991-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3304591|C00082|1991-02-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21337","name":"Sterling Mining Corporation"},"object":{"type":"mine","id":"3304591","name":"Shean Hill Mine"},"validFrom":"2007-07-27","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3304591|P21337|2007-07-27|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00082","name":"W Thomas  Mackall et al"},"object":{"type":"operator","id":"P21337","name":"Sterling Mining Corporation"},"validFrom":"2007-07-27","validTo":null,"current":true,"derived":true,"evidenceMineId":"3304591","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3304591|P21337|2007-07-27|C00082|1991-02-01|44070"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":10,"firstDate":"2011-01-09","lastDate":"2014-08-15","metrics":{"daysLost":7,"injuries":9,"fatalities":0,"recentRows":0,"restrictedDays":17,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"45432","DOCUMENT_NO":"220142450048","ACCIDENT_DT":"08/15/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Electrician was installing a pump in a sump located outside on the hill ramp leading to the pit. He slipped into the sump while installing the pump, caught himself on the cable to the pump, tearing muscles in chest area. Did not report accident till 9-2-14, after visits to hospital","sourceDate":"2014-08-15"},{"SOURCE_ROW_NUMBER":"152959","DOCUMENT_NO":"220140770017","ACCIDENT_DT":"03/10/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"A shard of flew off of drill steel while roof bolting at the face, and stuck in ee right pointer finger. Reported it to his fellow bolter and removed it and continued to work every day till Friday the 14th., where he reported it as infected and sought medical attention.","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"165939","DOCUMENT_NO":"220140130016","ACCIDENT_DT":"01/01/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While traveling from face to face while doing his normal maintence job, the miner caught his head on a roof bolt while driving on a man trip, spraining his neck. Miner waited to report the injury till 1-10-14, thinking it would heal over time, did not seek medical attention till that past week.","sourceDate":"2014-01-01"},{"SOURCE_ROW_NUMBER":"217534","DOCUMENT_NO":"220131160032","ACCIDENT_DT":"04/24/2013","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Scoop operator was hand shoveling along the rib at the face of the crosscut B-4 production hole on the return side, when a piece of roof approx. 15\" wide, 4' long and 10\" thick fell from the roof in between bolts and struck the operator on the right shoulder, dislocating his shoulder.","sourceDate":"2013-04-24"},{"SOURCE_ROW_NUMBER":"148743","DOCUMENT_NO":"220130780025","ACCIDENT_DT":"03/18/2013","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"While bolting a face cut. The bolter operator was in the process of preparing to drill the hole for the inside bolt on his side of the bolter. When the bit touched the roof, a piece of roof rock 1-2\" thick, 2' wide and 5' long fell from the roof. It hit the support arm of the ATRS and slid down it, hitting the bolter operator on the right side of his head, shoulder and chest.","sourceDate":"2013-03-18"},{"SOURCE_ROW_NUMBER":"15382","DOCUMENT_NO":"220121300026","ACCIDENT_DT":"05/08/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FIRE","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Operator of a CAT 980G loader had just taken a bucket of coal from the stockpile, when the loader quit. He turned to check the problem and found a fire under the hood. He proceeded to fight the fire with other mine personnel helping. The local fire department was contacted and arrived on scene to finish fighting. No one was injured","sourceDate":"2012-05-08"},{"SOURCE_ROW_NUMBER":"264883","DOCUMENT_NO":"220113350024","ACCIDENT_DT":"11/28/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"He was driving miner bits into the auger head of the miner, when something struck his left eye. He did not notice much discomfort and continued to work, even reporting to work the next day for his entire shift. Woke up the following day with discomfort and went to eye doctor. Tests found a sliver of metal in his left eye","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"260652","DOCUMENT_NO":"220112850019","ACCIDENT_DT":"10/11/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"While attempting to work loose a stuck drill steel in the roof, the drill steel became bound in the drill chuck with some side pressure. The drill steel snapped loose from the chuck striking the middle finger, lacerating the knuckle of his left hand.","sourceDate":"2011-10-11"},{"SOURCE_ROW_NUMBER":"41114","DOCUMENT_NO":"220111590018","ACCIDENT_DT":"06/07/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While attempting to replace a splice on the 3-Rt Conveyor Belt, employee was attempting to re-cut the belt for a new splice and when closing the belt cutter, he pulled his left hand back and caught his middle finger against the belt cutter blade, lacerating the tip of his finger, requiring 3 stitches","sourceDate":"2011-06-07"},{"SOURCE_ROW_NUMBER":"19647","DOCUMENT_NO":"220110130002","ACCIDENT_DT":"01/09/2011","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Bolter operator was installing a roof bolt and felt a pain in his back as he straightened the roof bolt. Worked the rest of the shift with some discomfort.","sourceDate":"2011-01-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-12-22","lastDate":"2017-12-22","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":201,"firstDate":"2008-03-13","lastDate":"2016-08-24","metrics":{"ss":57,"delinquent":191,"recentRows":0,"paidPenalty":32663,"proposedPenalty":32663,"currentAssessment":32663},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1741709","VIOLATION_NO":"9087277","ISSUE_DT":"08/24/2016","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-08-24"},{"SOURCE_ROW_NUMBER":"1741710","VIOLATION_NO":"9088757","ISSUE_DT":"08/17/2016","CFR_STANDARD_CD":"75.1714-3(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-08-17"},{"SOURCE_ROW_NUMBER":"1741928","VIOLATION_NO":"9088210","ISSUE_DT":"06/15/2016","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"114.00","CURRENT_ASSESSMENT_AMT":"114.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-06-15"},{"SOURCE_ROW_NUMBER":"1741717","VIOLATION_NO":"8042481","ISSUE_DT":"03/30/2016","CFR_STANDARD_CD":"49.17(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-03-30"},{"SOURCE_ROW_NUMBER":"1736467","VIOLATION_NO":"9084965","ISSUE_DT":"07/15/2015","CFR_STANDARD_CD":"75.825(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-07-15"},{"SOURCE_ROW_NUMBER":"1734704","VIOLATION_NO":"9082172","ISSUE_DT":"02/10/2015","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-02-10"},{"SOURCE_ROW_NUMBER":"1734703","VIOLATION_NO":"9082171","ISSUE_DT":"02/09/2015","CFR_STANDARD_CD":"75.1107-4(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-02-09"},{"SOURCE_ROW_NUMBER":"1734702","VIOLATION_NO":"9082170","ISSUE_DT":"02/05/2015","CFR_STANDARD_CD":"75.508-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-02-05"},{"SOURCE_ROW_NUMBER":"1734701","VIOLATION_NO":"9082168","ISSUE_DT":"02/03/2015","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-02-03"},{"SOURCE_ROW_NUMBER":"1734700","VIOLATION_NO":"9082167","ISSUE_DT":"02/03/2015","CFR_STANDARD_CD":"75.1501(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-02-03"},{"SOURCE_ROW_NUMBER":"1734699","VIOLATION_NO":"9082166","ISSUE_DT":"01/27/2015","CFR_STANDARD_CD":"75.380(d)(7)(v)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"1734698","VIOLATION_NO":"9082165","ISSUE_DT":"01/27/2015","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-01-27"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":449,"firstDate":"2008-11-17","lastDate":"2016-10-21","metrics":{"recentRows":0,"cpdmSamples":20,"voidSamples":52,"validSamples":397,"maxConcentration":5.564,"concentrationTotal":322.362},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1671392","SMP_TAKEN_DT":"10/21/2016","CONC":".626","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-21"},{"SOURCE_ROW_NUMBER":"1927193","SMP_TAKEN_DT":"10/20/2016","CONC":".526","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-20"},{"SOURCE_ROW_NUMBER":"2779656","SMP_TAKEN_DT":"10/19/2016","CONC":".737","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-19"},{"SOURCE_ROW_NUMBER":"2694039","SMP_TAKEN_DT":"10/18/2016","CONC":".71","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-18"},{"SOURCE_ROW_NUMBER":"2267050","SMP_TAKEN_DT":"10/17/2016","CONC":".458","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-17"},{"SOURCE_ROW_NUMBER":"2097448","SMP_TAKEN_DT":"10/13/2016","CONC":".673","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-13"},{"SOURCE_ROW_NUMBER":"1841026","SMP_TAKEN_DT":"10/12/2016","CONC":"1.348","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-12"},{"SOURCE_ROW_NUMBER":"1671278","SMP_TAKEN_DT":"10/11/2016","CONC":".714","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-11"},{"SOURCE_ROW_NUMBER":"2949418","SMP_TAKEN_DT":"10/10/2016","CONC":".617","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-10"},{"SOURCE_ROW_NUMBER":"1926603","SMP_TAKEN_DT":"10/7/2016","CONC":"1.167","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-07"},{"SOURCE_ROW_NUMBER":"2863744","SMP_TAKEN_DT":"10/6/2016","CONC":".429","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-06"},{"SOURCE_ROW_NUMBER":"1671012","SMP_TAKEN_DT":"10/4/2016","CONC":".611","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2016-10-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":79,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":15,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2007-07-27","lastDate":"2007-07-27","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":96,"firstDate":"2008-01-24","lastDate":"2018-03-21","metrics":{"inspectors":178,"recentRows":0,"onSiteHours":2681,"inspectionHours":5518,"inspectionSamples":450},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"93851","EVENT_NO":"6276421","INSPECTION_BEGIN_DT":"03/21/2018","INSPECTION_END_DT":"03/21/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2018-03-21"},{"SOURCE_ROW_NUMBER":"118750","EVENT_NO":"6277265","INSPECTION_BEGIN_DT":"12/29/2017","INSPECTION_END_DT":"12/29/2017","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2017-12-29"},{"SOURCE_ROW_NUMBER":"526129","EVENT_NO":"6273677","INSPECTION_BEGIN_DT":"11/02/2017","INSPECTION_END_DT":"12/29/2017","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.25","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2017-11-02"},{"SOURCE_ROW_NUMBER":"1144430","EVENT_NO":"6275894","INSPECTION_BEGIN_DT":"10/03/2017","INSPECTION_END_DT":"12/26/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"28.75","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2017-10-03"},{"SOURCE_ROW_NUMBER":"651881","EVENT_NO":"6276124","INSPECTION_BEGIN_DT":"08/15/2017","INSPECTION_END_DT":"08/16/2017","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2017-08-15"},{"SOURCE_ROW_NUMBER":"88301","EVENT_NO":"6277145","INSPECTION_BEGIN_DT":"07/19/2017","INSPECTION_END_DT":"08/02/2017","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.5","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2017-07-19"},{"SOURCE_ROW_NUMBER":"49974","EVENT_NO":"6273439","INSPECTION_BEGIN_DT":"07/06/2017","INSPECTION_END_DT":"09/26/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"62.5","SUM_TOTAL_ON_SITE_HOURS":"35","sourceDate":"2017-07-06"},{"SOURCE_ROW_NUMBER":"307080","EVENT_NO":"6273419","INSPECTION_BEGIN_DT":"05/19/2017","INSPECTION_END_DT":"05/25/2017","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2017-05-19"},{"SOURCE_ROW_NUMBER":"866420","EVENT_NO":"6273549","INSPECTION_BEGIN_DT":"04/03/2017","INSPECTION_END_DT":"06/29/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"74.5","SUM_TOTAL_ON_SITE_HOURS":"41.5","sourceDate":"2017-04-03"},{"SOURCE_ROW_NUMBER":"1094800","EVENT_NO":"6273314","INSPECTION_BEGIN_DT":"02/28/2017","INSPECTION_END_DT":"03/08/2017","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2017-02-28"},{"SOURCE_ROW_NUMBER":"724633","EVENT_NO":"6275605","INSPECTION_BEGIN_DT":"02/28/2017","INSPECTION_END_DT":"03/01/2017","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2017-02-28"},{"SOURCE_ROW_NUMBER":"768537","EVENT_NO":"6273628","INSPECTION_BEGIN_DT":"02/01/2017","INSPECTION_END_DT":"03/29/2017","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2017-02-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":95,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q4":{"hours":3259,"employees":5,"production":0},"2017-Q3":{"hours":1612,"employees":3,"production":2367},"2017-Q2":{"hours":2891,"employees":5,"production":2776},"2017-Q1":{"hours":2230,"employees":4,"production":1575},"2016-Q4":{"hours":3490,"employees":6,"production":3601},"2016-Q3":{"hours":2509,"employees":5,"production":4046},"2016-Q2":{"hours":4969,"employees":8,"production":3813},"2016-Q1":{"hours":1145,"employees":2,"production":7534},"2015-Q4":{"hours":10277,"employees":18,"production":22955},"2015-Q3":{"hours":3658,"employees":7,"production":23280},"2015-Q2":{"hours":13801,"employees":25,"production":27880},"2015-Q1":{"hours":18213,"employees":31,"production":43888}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":22,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":4030,"employees":8,"production":5497},"2009":{"hours":66503,"employees":28,"production":178241},"2010":{"hours":86455,"employees":36,"production":239111},"2011":{"hours":85620,"employees":38,"production":261374},"2012":{"hours":82497,"employees":35,"production":240399},"2013":{"hours":71694,"employees":31,"production":206488},"2014":{"hours":82794,"employees":32,"production":243045},"2015":{"hours":45949,"employees":20,"production":118003},"2016":{"hours":12113,"employees":6,"production":18994},"2017":{"hours":9992,"employees":4,"production":6718}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":42,"firstDate":"2009-06-24","lastDate":"2015-01-27","metrics":{"recentRows":0,"doseOver100":13,"actDoseTotal":3226,"pelDoseTotal":2426},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"133193","EVENT_NO":"6269169","SURVEY_DATE":"01/27/2015","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"133192","EVENT_NO":"6269169","SURVEY_DATE":"01/27/2015","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"02","MANUFACTURER_CD":"038","ACT_DOSE_85":"10","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"133191","EVENT_NO":"6269169","SURVEY_DATE":"01/27/2015","OCCUPATION_CD_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"40","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"133190","EVENT_NO":"6269169","SURVEY_DATE":"01/27/2015","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"59","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"133189","EVENT_NO":"6269169","SURVEY_DATE":"01/27/2015","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"067","ACT_DOSE_85":"25","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"133188","EVENT_NO":"6263131","SURVEY_DATE":"03/04/2014","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"8","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"133187","EVENT_NO":"6263131","SURVEY_DATE":"03/04/2014","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"119","ACT_DOSE_85":"55","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"133186","EVENT_NO":"6263131","SURVEY_DATE":"03/04/2014","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"133185","EVENT_NO":"6263131","SURVEY_DATE":"03/04/2014","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"038","ACT_DOSE_85":"115","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"133184","EVENT_NO":"6263131","SURVEY_DATE":"03/04/2014","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"038","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"133183","EVENT_NO":"6263131","SURVEY_DATE":"03/04/2014","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"133182","EVENT_NO":"6263131","SURVEY_DATE":"03/04/2014","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"99","PEL_DOSE_90":"73","SURVEY_TYPE":"I","sourceDate":"2014-03-04"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":14,"firstDate":"2010-09-22","lastDate":"2015-01-20","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":6.7,"validSamples":13,"quartzPctTotal":62.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"43358","CASSETTE_NO":"58186469","SAMPLE_DT":"01/20/2015","QUARTZ_PCT":"03.1","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-01-20"},{"SOURCE_ROW_NUMBER":"30363","CASSETTE_NO":"58005598","SAMPLE_DT":"05/29/2013","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-05-29"},{"SOURCE_ROW_NUMBER":"127078","CASSETTE_NO":"57994461","SAMPLE_DT":"11/07/2012","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-11-07"},{"SOURCE_ROW_NUMBER":"160312","CASSETTE_NO":"57960141","SAMPLE_DT":"06/05/2012","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"4052","CASSETTE_NO":"57959713","SAMPLE_DT":"02/09/2012","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-02-09"},{"SOURCE_ROW_NUMBER":"49796","CASSETTE_NO":"57964075","SAMPLE_DT":"12/07/2011","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-07"},{"SOURCE_ROW_NUMBER":"44596","CASSETTE_NO":"57964143","SAMPLE_DT":"12/07/2011","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-07"},{"SOURCE_ROW_NUMBER":"159163","CASSETTE_NO":"51165433","SAMPLE_DT":"10/12/2011","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2011-10-12"},{"SOURCE_ROW_NUMBER":"33842","CASSETTE_NO":"57957846","SAMPLE_DT":"09/22/2011","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-22"},{"SOURCE_ROW_NUMBER":"89185","CASSETTE_NO":"57905365","SAMPLE_DT":"06/01/2011","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-06-01"},{"SOURCE_ROW_NUMBER":"110778","CASSETTE_NO":"51091700","SAMPLE_DT":"10/28/2010","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-28"},{"SOURCE_ROW_NUMBER":"120592","CASSETTE_NO":"57878384","SAMPLE_DT":"10/14/2010","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-14"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":200,"firstDate":"2008-03-13","lastDate":"2016-08-24","metrics":{"ss":56,"amountDue":31359,"contested":0,"amountPaid":31359,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":31359},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1772648","VIOLATION_NO":"9087277","VIOLATION_ISSUE_DT":"08/24/2016","SIG_SUB":"N","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/31/2016","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2016-08-24"},{"SOURCE_ROW_NUMBER":"1772649","VIOLATION_NO":"9088757","VIOLATION_ISSUE_DT":"08/17/2016","SIG_SUB":"N","PART_SECTION":"75.1714-3(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/24/2016","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2016-08-17"},{"SOURCE_ROW_NUMBER":"1772623","VIOLATION_NO":"9088210","VIOLATION_ISSUE_DT":"06/15/2016","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/15/2016","PROPOSED_PENALTY":"114","AMOUNT_DUE":"114","AMOUNT_PAID":"114","CONTESTED_IND":"N","sourceDate":"2016-06-15"},{"SOURCE_ROW_NUMBER":"1772553","VIOLATION_NO":"8042481","VIOLATION_ISSUE_DT":"03/30/2016","SIG_SUB":"N","PART_SECTION":"49.17(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/08/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-03-30"},{"SOURCE_ROW_NUMBER":"1772631","VIOLATION_NO":"9084965","VIOLATION_ISSUE_DT":"07/15/2015","SIG_SUB":"N","PART_SECTION":"75.825(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/22/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-07-15"},{"SOURCE_ROW_NUMBER":"1772568","VIOLATION_NO":"9082172","VIOLATION_ISSUE_DT":"02/10/2015","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/19/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-02-10"},{"SOURCE_ROW_NUMBER":"1772567","VIOLATION_NO":"9082171","VIOLATION_ISSUE_DT":"02/09/2015","SIG_SUB":"Y","PART_SECTION":"75.1107-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/10/2015","PROPOSED_PENALTY":"127","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"N","sourceDate":"2015-02-09"},{"SOURCE_ROW_NUMBER":"1772566","VIOLATION_NO":"9082170","VIOLATION_ISSUE_DT":"02/05/2015","SIG_SUB":"N","PART_SECTION":"75.508-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/05/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-02-05"},{"SOURCE_ROW_NUMBER":"1772565","VIOLATION_NO":"9082168","VIOLATION_ISSUE_DT":"02/03/2015","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/03/2015","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2015-02-03"},{"SOURCE_ROW_NUMBER":"1772564","VIOLATION_NO":"9082167","VIOLATION_ISSUE_DT":"02/03/2015","SIG_SUB":"N","PART_SECTION":"75.1501(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/04/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-02-03"},{"SOURCE_ROW_NUMBER":"1772563","VIOLATION_NO":"9082166","VIOLATION_ISSUE_DT":"01/27/2015","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(v)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/03/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-01-27"},{"SOURCE_ROW_NUMBER":"1772562","VIOLATION_NO":"9082165","VIOLATION_ISSUE_DT":"01/27/2015","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/27/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-01-27"}]}],"safety":{"href":"/api/v1/mines/3304591/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3304591/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Physical requirements for mine rescue team.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-49/subpart-B/section-49.17","part":"49","subchapter":"H","subpart":"B","id":"49.17","citation":"30 CFR 49.17","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 49—MINE RESCUE TEAMS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Power centers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.825","part":"75","subchapter":"O","subpart":"I","id":"75.825","citation":"30 CFR 75.825","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","heading":"Changes in electric system map; recording.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.508-2","part":"75","subchapter":"O","subpart":"F","id":"75.508-2","citation":"30 CFR 75.508-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","heading":"Emergency evacuations.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1501","part":"75","subchapter":"O","subpart":"P","id":"75.1501","citation":"30 CFR 75.1501","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3304591","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}