{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3304230","name":"Sterling North Mine","status":"Abandoned and Sealed","status_date":"2003-07-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"OH","county":"Jefferson","nearest_town":"Salineville","operator_id":"P21337","operator_name":"Sterling Mining Corp","controller_id":"C00082","controller_name":"W Thomas  Mackall","district":"C03","office":"St. Clairsville OH Field Office","employees":0,"latitude":40.536111,"longitude":-80.836111},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":400},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3304230","name":"Sterling North Mine"},"operator":{"type":"operator","id":"P21337","name":"Sterling Mining Corp"},"controller":{"type":"controller","id":"C00082","name":"W Thomas  Mackall"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21337","name":"Sterling Mining Corp"},"object":{"type":"mine","id":"3304230","name":"Sterling North Mine"},"validFrom":"1991-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3304230|P21337|1991-02-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00082","name":"W Thomas  Mackall et al"},"object":{"type":"mine","id":"3304230","name":"Sterling North Mine"},"validFrom":"1991-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3304230|C00082|1991-02-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00082","name":"W Thomas  Mackall et al"},"object":{"type":"operator","id":"P21337","name":"Sterling Mining Corp"},"validFrom":"1991-02-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"3304230","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3304230|P21337|1991-02-01|C00082|1991-02-01|44065"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":7,"firstDate":"2000-03-20","lastDate":"2002-02-20","metrics":{"daysLost":21,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":9,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"247688","DOCUMENT_NO":"220020560147","ACCIDENT_DT":"02/20/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL IN ABANDONED 3 LEFT PANEL AT FACE INTERSECTION OF #6 ENTRY B-23. APPROX 19' WIDE AND 30' LONG, 8' HIGH. EXTENDS FROM IN BY B-22 #6 ENTRY TO FACE (THRU INTERSECTION) TO OLD FACE OF #6 ENTRY AT END OF PANEL. AREA POSITIONED ANDDANGERED OFF. DID NOT AFFECT VENTILATION.","sourceDate":"2002-02-20"},{"SOURCE_ROW_NUMBER":"19625","DOCUMENT_NO":"220013340038","ACCIDENT_DT":"11/26/2001","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"15","NARRATIVE":"THE MINER WAS HELPING TO DO A BELT MOVE AND WAS THROWING BELT STRUCTURE NEAR THE BELT TO INSTALL. AFTER RELEASING A PIECE WHILE THROWING THE MINER FELT A PAIN IN HIS BACK. NO HORSE PLAY OR SAFETY VIOLATION WAS THE CAUSE. COMPLIANCE WITH RULES AND REGS NOT A FACTOR. PROTECTIVE ITEMS OR TRAINING NOT A FACTOR.","sourceDate":"2001-11-26"},{"SOURCE_ROW_NUMBER":"114147","DOCUMENT_NO":"220012470194","ACCIDENT_DT":"08/30/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL OF BREAK 5, #5 ENTRY AT INTERSECTION. APPROXIMATELY 20 X 20 FT IN AREA, 10' HIGH EXTENDING INTO #3 ENTRY OF ROOM-1 RIGHT. FOUND BY FOREMAN & MSHA INSPECTOR ON NORMAL INSPECTION.","sourceDate":"2001-08-30"},{"SOURCE_ROW_NUMBER":"19624","DOCUMENT_NO":"220010590025","ACCIDENT_DT":"02/23/2001","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","NARRATIVE":"ALL 4 MOBILE BRIDGES WERE BACKING OUT OF A CUT, WHEN THE FRONT 2 BRIDGES (#4 & #3) STOPPED AND STARTED MOVING FORWARD, WHILE #2 & #1 BRIDGES WERE STILL BACKING. SUDDEN STOP CAUSED THE #2 & #3 BRIDGE TO SLIDE TOWARD THE OPERATOR CATCHING HIS KNEE PAD UNDER THE MACHINE PINNING HIM AGAINST THE RIB. OPERATOR HIT PANIC BAR, BUT IT FAILED TO DISENGAGE. IMMEDIATE REPAIR TO PANIC AFTER AID","sourceDate":"2001-02-23"},{"SOURCE_ROW_NUMBER":"234723","DOCUMENT_NO":"220003140050","ACCIDENT_DT":"11/05/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"ROOF FALL OCCURRED SOMETIME BETWEEN 12:00 AM ON 11-4 AND 9:00 PM 11-5. FOUND BY MINE FOREMAN DOING PRESHIFT FOR 11:00 PM MIDNIGHT SHIFT (SUN-MON) APPROX 6' HIGH 100' LONG IN BY INTERSECTION OF B-13 TO JUST INTO INTERSECTION 13-15 OF 5 RIGHTOFF OF 1 LEFT. FALL WAS POSTED AND DANGERED OFF.","sourceDate":"2000-11-05"},{"SOURCE_ROW_NUMBER":"256247","DOCUMENT_NO":"220001430125","ACCIDENT_DT":"05/19/2000","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"FLOOR HEAVE OF #1 THRU #7 ENTRIES OF 3-LEFT ROOM OFF OF 1-LEFT SOUTHEAST SUBMAINS. FROM BREAK 1 TO BREAK 12, MOST CROSS CUTS REMAINED OPEN.","sourceDate":"2000-05-19"},{"SOURCE_ROW_NUMBER":"191566","DOCUMENT_NO":"220000870085","ACCIDENT_DT":"03/20/2000","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"EE WAS ASSISTING IN HELPING TO TRY TO TIGHTEN UP THE CONVEYOR TAIL PIECE WHEN THE WRENCH HE WAS USING TO HELP TENSION THE TAILPIECE BROKE, CAUSING A PORTION OF THE WRENCH TO FLY LOOSE AND STRI KING HIM ON THE RIGHT SIDE OF HIS FACE. CAUSE OF INJURY WAS AWARENESS COMPLIANCE WITH RULES AND REGS WAS NOT A FACTOR, PROTECTIVE ITEMS OR TRAINING NOT A FACTOR.","sourceDate":"2000-03-20"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2003-07-01","lastDate":"2003-07-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":75,"firstDate":"2000-02-08","lastDate":"2002-05-28","metrics":{"ss":34,"delinquent":75,"recentRows":0,"paidPenalty":6430,"proposedPenalty":6430,"currentAssessment":6430},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"736033","VIOLATION_NO":"4888324","ISSUE_DT":"05/28/2002","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-28"},{"SOURCE_ROW_NUMBER":"736032","VIOLATION_NO":"4888323","ISSUE_DT":"05/28/2002","CFR_STANDARD_CD":"75.1101-23(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-28"},{"SOURCE_ROW_NUMBER":"736035","VIOLATION_NO":"7133992","ISSUE_DT":"05/09/2002","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-09"},{"SOURCE_ROW_NUMBER":"736034","VIOLATION_NO":"7133991","ISSUE_DT":"05/09/2002","CFR_STANDARD_CD":"75.507-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-05-09"},{"SOURCE_ROW_NUMBER":"736031","VIOLATION_NO":"4888321","ISSUE_DT":"04/17/2002","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-17"},{"SOURCE_ROW_NUMBER":"736030","VIOLATION_NO":"4888320","ISSUE_DT":"04/16/2002","CFR_STANDARD_CD":"75.203(e)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-04-16"},{"SOURCE_ROW_NUMBER":"737682","VIOLATION_NO":"7133938","ISSUE_DT":"01/22/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-01-22"},{"SOURCE_ROW_NUMBER":"737681","VIOLATION_NO":"7133697","ISSUE_DT":"01/22/2002","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"131.00","CURRENT_ASSESSMENT_AMT":"131.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-01-22"},{"SOURCE_ROW_NUMBER":"737680","VIOLATION_NO":"7133696","ISSUE_DT":"01/22/2002","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-01-22"},{"SOURCE_ROW_NUMBER":"735933","VIOLATION_NO":"4868933","ISSUE_DT":"11/28/2001","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"735932","VIOLATION_NO":"4868932","ISSUE_DT":"11/21/2001","CFR_STANDARD_CD":"77.1301(c)(11)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-21"},{"SOURCE_ROW_NUMBER":"735931","VIOLATION_NO":"4868931","ISSUE_DT":"11/21/2001","CFR_STANDARD_CD":"77.700","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-11-21"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":161,"firstDate":"2000-02-08","lastDate":"2002-03-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":10,"validSamples":151,"maxConcentration":27.74,"concentrationTotal":212.226},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"523500","CASS_NUM":"50579315","SMP_TAKEN_DT":"3/25/2002","CONC":"1.599","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-25"},{"SOURCE_ROW_NUMBER":"957058","CASS_NUM":"50579344","SMP_TAKEN_DT":"3/22/2002","CONC":"1.313","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-22"},{"SOURCE_ROW_NUMBER":"1426218","CASS_NUM":"50579270","SMP_TAKEN_DT":"3/21/2002","CONC":"1.178","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-21"},{"SOURCE_ROW_NUMBER":"1541806","CASS_NUM":"50579309","SMP_TAKEN_DT":"3/20/2002","CONC":"1.119","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"1203927","CASS_NUM":"57396364","SMP_TAKEN_DT":"3/20/2002","CONC":"1.925","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"974233","CASS_NUM":"57396400","SMP_TAKEN_DT":"3/20/2002","CONC":"1.091","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"772397","CASS_NUM":"57396468","SMP_TAKEN_DT":"3/20/2002","CONC":"2.195","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"758713","CASS_NUM":"57396379","SMP_TAKEN_DT":"3/20/2002","CONC":"1.663","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"545789","CASS_NUM":"57396390","SMP_TAKEN_DT":"3/20/2002","CONC":".822","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"134629","CASS_NUM":"57396437","SMP_TAKEN_DT":"3/20/2002","CONC":"1.473","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"1812","CASS_NUM":"57396078","SMP_TAKEN_DT":"3/20/2002","CONC":"1.086","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"1420190","CASS_NUM":"50579348","SMP_TAKEN_DT":"3/19/2002","CONC":"1.507","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"AUGER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-19"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2001-07-10","lastDate":"2001-07-10","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"1991-02-01","lastDate":"1991-02-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":31,"firstDate":"2000-01-19","lastDate":"2002-07-09","metrics":{"inspectors":33,"recentRows":0,"onSiteHours":542.5,"inspectionHours":1124.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"156343","EVENT_NO":"4068692","INSPECTION_BEGIN_DT":"07/09/2002","INSPECTION_END_DT":"07/09/2002","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2002-07-09"},{"SOURCE_ROW_NUMBER":"949591","EVENT_NO":"4068422","INSPECTION_BEGIN_DT":"05/05/2002","INSPECTION_END_DT":"05/21/2002","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2002-05-05"},{"SOURCE_ROW_NUMBER":"4296","EVENT_NO":"4067863","INSPECTION_BEGIN_DT":"04/02/2002","INSPECTION_END_DT":"06/14/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"88.5","SUM_TOTAL_ON_SITE_HOURS":"41.5","sourceDate":"2002-04-02"},{"SOURCE_ROW_NUMBER":"1110356","EVENT_NO":"4068302","INSPECTION_BEGIN_DT":"12/31/2001","INSPECTION_END_DT":"03/27/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"70","SUM_TOTAL_ON_SITE_HOURS":"33.5","sourceDate":"2001-12-31"},{"SOURCE_ROW_NUMBER":"484802","EVENT_NO":"4061440","INSPECTION_BEGIN_DT":"12/11/2001","INSPECTION_END_DT":"12/14/2001","ACTIVITY_CODE":"CCA","ACTIVITY":"ROOF CONTROL TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2001-12-11"},{"SOURCE_ROW_NUMBER":"72402","EVENT_NO":"4068265","INSPECTION_BEGIN_DT":"11/05/2001","INSPECTION_END_DT":"11/29/2001","ACTIVITY_CODE":"CCC","ACTIVITY":"VENTILATION TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2001-11-05"},{"SOURCE_ROW_NUMBER":"696764","EVENT_NO":"4074995","INSPECTION_BEGIN_DT":"10/16/2001","INSPECTION_END_DT":"10/16/2001","ACTIVITY_CODE":"CCD","ACTIVITY":"NOISE TECHNICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2001-10-16"},{"SOURCE_ROW_NUMBER":"621986","EVENT_NO":"4067857","INSPECTION_BEGIN_DT":"10/01/2001","INSPECTION_END_DT":"12/27/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"112","SUM_TOTAL_ON_SITE_HOURS":"56.5","sourceDate":"2001-10-01"},{"SOURCE_ROW_NUMBER":"621678","EVENT_NO":"4067808","INSPECTION_BEGIN_DT":"08/20/2001","INSPECTION_END_DT":"09/17/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2001-08-20"},{"SOURCE_ROW_NUMBER":"305929","EVENT_NO":"4067807","INSPECTION_BEGIN_DT":"08/07/2001","INSPECTION_END_DT":"08/10/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2001-08-07"},{"SOURCE_ROW_NUMBER":"969932","EVENT_NO":"4067806","INSPECTION_BEGIN_DT":"07/30/2001","INSPECTION_END_DT":"09/17/2001","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"62","SUM_TOTAL_ON_SITE_HOURS":"27","sourceDate":"2001-07-30"},{"SOURCE_ROW_NUMBER":"693886","EVENT_NO":"6102843","INSPECTION_BEGIN_DT":"06/14/2001","INSPECTION_END_DT":"06/15/2001","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2001-06-14"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q3":{"hours":5660,"employees":11,"production":8097},"2002-Q2":{"hours":8784,"employees":16,"production":32603},"2002-Q1":{"hours":7828,"employees":17,"production":40314},"2001-Q4":{"hours":10988,"employees":20,"production":63077},"2001-Q3":{"hours":7379,"employees":11,"production":33294},"2001-Q2":{"hours":5868,"employees":10,"production":54769},"2001-Q1":{"hours":7398,"employees":12,"production":42371},"2000-Q4":{"hours":9241,"employees":17,"production":49613},"2000-Q3":{"hours":5761,"employees":16,"production":28968},"2000-Q2":{"hours":12563,"employees":22,"production":64228},"2000-Q1":{"hours":12788,"employees":18,"production":14898}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":40353,"employees":18,"production":157707},"2001":{"hours":31633,"employees":13,"production":193511},"2002":{"hours":22272,"employees":15,"production":81014}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":12,"firstDate":"2000-03-23","lastDate":"2001-08-20","metrics":{"recentRows":0,"doseOver100":7,"actDoseTotal":1673,"pelDoseTotal":1349},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"130957","EVENT_NO":"4067808","SURVEY_DATE":"08/20/2001","OCCUPATION_CD_DESC":"AUGER OPERATOR","MACHINE_CD":"07","MANUFACTURER_CD":"038","ACT_DOSE_85":"178","PEL_DOSE_90":"120","SURVEY_TYPE":"F","sourceDate":"2001-08-20"},{"SOURCE_ROW_NUMBER":"130956","EVENT_NO":"4067808","SURVEY_DATE":"08/20/2001","OCCUPATION_CD_DESC":"AUGER OPERATOR","MACHINE_CD":"07","MANUFACTURER_CD":"038","ACT_DOSE_85":"193","PEL_DOSE_90":"119","SURVEY_TYPE":"F","sourceDate":"2001-08-20"},{"SOURCE_ROW_NUMBER":"130955","EVENT_NO":"4067807","SURVEY_DATE":"08/07/2001","OCCUPATION_CD_DESC":"AUGER OPERATOR","MACHINE_CD":"07","MANUFACTURER_CD":"038","ACT_DOSE_85":"260","PEL_DOSE_90":"253","SURVEY_TYPE":"F","sourceDate":"2001-08-07"},{"SOURCE_ROW_NUMBER":"130966","EVENT_NO":"6102843","SURVEY_DATE":"06/14/2001","OCCUPATION_CD_DESC":"AUGER OPERATOR","MACHINE_CD":"02","MANUFACTURER_CD":"038","ACT_DOSE_85":"305","PEL_DOSE_90":"293","SURVEY_TYPE":"I","sourceDate":"2001-06-14"},{"SOURCE_ROW_NUMBER":"130965","EVENT_NO":"6102843","SURVEY_DATE":"06/14/2001","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"038","ACT_DOSE_85":"108","PEL_DOSE_90":"100","SURVEY_TYPE":"I","sourceDate":"2001-06-14"},{"SOURCE_ROW_NUMBER":"130964","EVENT_NO":"6102843","SURVEY_DATE":"06/14/2001","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"038","ACT_DOSE_85":"84","PEL_DOSE_90":"59","SURVEY_TYPE":"I","sourceDate":"2001-06-14"},{"SOURCE_ROW_NUMBER":"130963","EVENT_NO":"6102843","SURVEY_DATE":"06/14/2001","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"40","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2001-06-14"},{"SOURCE_ROW_NUMBER":"130962","EVENT_NO":"6102843","SURVEY_DATE":"06/14/2001","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"53","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2001-06-14"},{"SOURCE_ROW_NUMBER":"130961","EVENT_NO":"4070410","SURVEY_DATE":"03/23/2000","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"72","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2000-03-23"},{"SOURCE_ROW_NUMBER":"130960","EVENT_NO":"4070410","SURVEY_DATE":"03/23/2000","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"37","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2000-03-23"},{"SOURCE_ROW_NUMBER":"130959","EVENT_NO":"4070410","SURVEY_DATE":"03/23/2000","OCCUPATION_CD_DESC":"MOBILE BRIDGE OPERATOR","MACHINE_CD":"08","MANUFACTURER_CD":"038","ACT_DOSE_85":"118","PEL_DOSE_90":"80","SURVEY_TYPE":"I","sourceDate":"2000-03-23"},{"SOURCE_ROW_NUMBER":"130958","EVENT_NO":"4070410","SURVEY_DATE":"03/23/2000","OCCUPATION_CD_DESC":"AUGER OPERATOR","MACHINE_CD":"02","MANUFACTURER_CD":"038","ACT_DOSE_85":"225","PEL_DOSE_90":"212","SURVEY_TYPE":"I","sourceDate":"2000-03-23"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":16,"firstDate":"2000-03-23","lastDate":"2002-03-20","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":5.6,"validSamples":16,"quartzPctTotal":42.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"157088","CASSETTE_NO":"57396437","SAMPLE_DT":"03/20/2002","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"123527","CASSETTE_NO":"57396468","SAMPLE_DT":"03/20/2002","QUARTZ_PCT":"00.4","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-03-20"},{"SOURCE_ROW_NUMBER":"100483","CASSETTE_NO":"57382037","SAMPLE_DT":"01/15/2002","QUARTZ_PCT":"03.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-01-15"},{"SOURCE_ROW_NUMBER":"146932","CASSETTE_NO":"57354242","SAMPLE_DT":"06/07/2001","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-07"},{"SOURCE_ROW_NUMBER":"110251","CASSETTE_NO":"57354497","SAMPLE_DT":"06/07/2001","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-06-07"},{"SOURCE_ROW_NUMBER":"55815","CASSETTE_NO":"57354396","SAMPLE_DT":"05/24/2001","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-24"},{"SOURCE_ROW_NUMBER":"42048","CASSETTE_NO":"57354326","SAMPLE_DT":"05/24/2001","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-24"},{"SOURCE_ROW_NUMBER":"137923","CASSETTE_NO":"57331740","SAMPLE_DT":"02/06/2001","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-06"},{"SOURCE_ROW_NUMBER":"154102","CASSETTE_NO":"57292332","SAMPLE_DT":"10/24/2000","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-24"},{"SOURCE_ROW_NUMBER":"47163","CASSETTE_NO":"57292294","SAMPLE_DT":"10/24/2000","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-24"},{"SOURCE_ROW_NUMBER":"168399","CASSETTE_NO":"57279212","SAMPLE_DT":"07/26/2000","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"AUGER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-07-26"},{"SOURCE_ROW_NUMBER":"22525","CASSETTE_NO":"57279214","SAMPLE_DT":"07/26/2000","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-07-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":75,"firstDate":"2000-02-08","lastDate":"2002-05-28","metrics":{"ss":34,"amountDue":6430,"contested":0,"amountPaid":6430,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":6430},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1757462","VIOLATION_NO":"4888324","VIOLATION_ISSUE_DT":"05/28/2002","SIG_SUB":"Y","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-05-28"},{"SOURCE_ROW_NUMBER":"1757461","VIOLATION_NO":"4888323","VIOLATION_ISSUE_DT":"05/28/2002","SIG_SUB":"N","PART_SECTION":"75.1101-23(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-05-28"},{"SOURCE_ROW_NUMBER":"1757464","VIOLATION_NO":"7133992","VIOLATION_ISSUE_DT":"05/09/2002","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-05-09"},{"SOURCE_ROW_NUMBER":"1757463","VIOLATION_NO":"7133991","VIOLATION_ISSUE_DT":"05/09/2002","SIG_SUB":"N","PART_SECTION":"75.507-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/09/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-05-09"},{"SOURCE_ROW_NUMBER":"1757460","VIOLATION_NO":"4888321","VIOLATION_ISSUE_DT":"04/17/2002","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/17/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-04-17"},{"SOURCE_ROW_NUMBER":"1757459","VIOLATION_NO":"4888320","VIOLATION_ISSUE_DT":"04/16/2002","SIG_SUB":"Y","PART_SECTION":"75.203(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/17/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-04-16"},{"SOURCE_ROW_NUMBER":"1757518","VIOLATION_NO":"7133938","VIOLATION_ISSUE_DT":"01/22/2002","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/21/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-01-22"},{"SOURCE_ROW_NUMBER":"1757517","VIOLATION_NO":"7133697","VIOLATION_ISSUE_DT":"01/22/2002","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/21/2002","PROPOSED_PENALTY":"131","AMOUNT_DUE":"131","AMOUNT_PAID":"131","CONTESTED_IND":"N","sourceDate":"2002-01-22"},{"SOURCE_ROW_NUMBER":"1757516","VIOLATION_NO":"7133696","VIOLATION_ISSUE_DT":"01/22/2002","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/22/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-01-22"},{"SOURCE_ROW_NUMBER":"1757501","VIOLATION_NO":"4868933","VIOLATION_ISSUE_DT":"11/28/2001","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/28/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-28"},{"SOURCE_ROW_NUMBER":"1757500","VIOLATION_NO":"4868932","VIOLATION_ISSUE_DT":"11/21/2001","SIG_SUB":"N","PART_SECTION":"77.1301(c)(11)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/28/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-21"},{"SOURCE_ROW_NUMBER":"1757499","VIOLATION_NO":"4868931","VIOLATION_ISSUE_DT":"11/21/2001","SIG_SUB":"N","PART_SECTION":"77.700","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/28/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-11-21"}]}],"safety":{"href":"/api/v1/mines/3304230/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3304230/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment other than power-connection points; outby the last open crosscut; return air; permissibility requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.507-1","part":"75","subchapter":"O","subpart":"F","id":"75.507-1","citation":"30 CFR 75.507-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","heading":"Mining methods.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.203","part":"75","subchapter":"O","subpart":"C","id":"75.203","citation":"30 CFR 75.203","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"Explosives; magazines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-N/section-77.1301","part":"77","subchapter":"O","subpart":"N","id":"77.1301","citation":"30 CFR 77.1301","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic sheaths, armors, and conduits enclosing power conductors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.700","part":"77","subchapter":"O","subpart":"H","id":"77.700","citation":"30 CFR 77.700","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3304230","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}