{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"3301172","name":"Meigs #31 Mine","status":"NonProducing","status_date":"2001-10-24","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"OH","county":"Meigs","nearest_town":"Langsville","operator_id":"0130893","operator_name":"CONSOL Mining Company LLC","controller_id":"0189840","controller_name":"Core Natural Resources Inc","district":"C04","office":"Mt. Carbon WV Field Office","employees":25,"latitude":39.054444,"longitude":-82.241944},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2274},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"operator":{"type":"operator","id":"0130893","name":"CONSOL Mining Company LLC"},"controller":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P00406","name":"Southern Ohio Coal Company"},"object":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"validFrom":"1950-01-01","validTo":"2001-07-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|P00406|1950-01-01|2001-07-01"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00329","name":"American Electric Power Company Inc"},"object":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"validFrom":"1950-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|C00329|1950-01-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00329","name":"American Electric Power Company Inc"},"object":{"type":"operator","id":"P00406","name":"Southern Ohio Coal Company"},"validFrom":"1950-01-01","validTo":"2001-07-01","current":false,"derived":true,"evidenceMineId":"3301172","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|P00406|1950-01-01|C00329|1950-01-01|46078"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24678","name":"Southern Ohio Coal Company"},"object":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"validFrom":"2001-07-02","validTo":"2013-12-05","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|P24678|2001-07-02|2013-12-05"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"validFrom":"2001-07-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|C00692|2001-07-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"operator","id":"P24678","name":"Southern Ohio Coal Company"},"validFrom":"2001-07-02","validTo":"2013-12-05","current":false,"derived":true,"evidenceMineId":"3301172","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|P24678|2001-07-02|C00692|2001-07-02|49354"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0130893","name":"CONSOL Mining Company LLC"},"object":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"validFrom":"2013-12-06","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|0130893|2013-12-06|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"validFrom":"2013-12-06","validTo":"2025-01-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|C00692|2013-12-06|2025-01-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00692","name":"CONSOL Energy Inc"},"object":{"type":"operator","id":"0130893","name":"CONSOL Mining Company LLC"},"validFrom":"2013-12-06","validTo":"2025-01-13","current":false,"derived":true,"evidenceMineId":"3301172","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|0130893|2013-12-06|C00692|2013-12-06|49407"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"object":{"type":"mine","id":"3301172","name":"Meigs #31 Mine"},"validFrom":"2025-01-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|0189840|2025-01-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0189840","name":"Core Natural Resources Inc"},"object":{"type":"operator","id":"0130893","name":"CONSOL Mining Company LLC"},"validFrom":"2025-01-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"3301172","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"3301172|0130893|2013-12-06|0189840|2025-01-14|40438"}}],"coverage":{"historyRecords":4,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":95,"firstDate":"2000-01-06","lastDate":"2025-01-15","metrics":{"daysLost":1853,"injuries":87,"fatalities":0,"recentRows":1,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"234686","DOCUMENT_NO":"220250210037","ACCIDENT_DT":"01/15/2025","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"52","NARRATIVE":"Employee walking down an incline to the boot washroom slipped on ice fell on left wrist. There were steps and a walkway that could use, the employee took a short cut. This wasn't reported till the next day at 9:30am","sourceDate":"2025-01-15"},{"SOURCE_ROW_NUMBER":"187346","DOCUMENT_NO":"220020770032","ACCIDENT_DT":"02/21/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Backhoe operator, Trackhoe operator, Crane operator","NO_INJURIES":"1","DAYS_LOST":"34","NARRATIVE":"EE HAD STARTED HIS SHIFT AT 500 AM AND HAD WALKED INTO THE DIESEL SHOP TO SEE IF THE D-9R DOZER THAT HE OPERATES HAD BEEN REPAIRED. THE DOZER HAD BEEN DOWN DUE TO ENGINE PROBLEMS. HE STEPPED U P ON ONE OF THE TRACK ASSEMBLIES, TO LOOK AT THEENGINE, WHEN HE LOST HIS BALANCE AND FELL. WHEN HE FELL HIS RIGHT RIB CAGE STRUCK THE DOZER BLADES PUSH-ARM.","sourceDate":"2002-02-21"},{"SOURCE_ROW_NUMBER":"92597","DOCUMENT_NO":"220020560128","ACCIDENT_DT":"02/09/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"DIESEL MECHANIC WAS REQUESTED TO CHECK THE OPERATION OF THE GEAR SHIFTER ON THE NO.9902 DART HAULAGE TRUCK. AFTER MAKING HIS CHECK HE EXITED THE TRUCK OPERATOR CAB AND WAS PREPARING TO DESCEND DOWN THE TRUCKS LADDER. AT THAT TIME THE TRUCKS OPERATOR CLOSED THE DOOR, NOT KNOWING HIS RIGHT HAND WAS ON THE DOOR POST, THIS PINCHED RIGHT MIDDLE FINGER, PARTIALLY REMOVING FINGER NAIL.","sourceDate":"2002-02-09"},{"SOURCE_ROW_NUMBER":"269066","DOCUMENT_NO":"220013270039","ACCIDENT_DT":"11/06/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"EMPLOYEE WAS PREPARING TO BOARD A MANTRIP WHEN HE STEPPED ON A BELT ROLLER CAUSING HIM TO FALL. WHEN HE FELL (BACKWARDS) HIS HEAD STRUCK A CONVEYER BELT RAIL. THIS RESULTED INTO A CONCUSSION. HE BEGAN TO MISS WORK ON 11-7-01.","sourceDate":"2001-11-06"},{"SOURCE_ROW_NUMBER":"195790","DOCUMENT_NO":"220013250024","ACCIDENT_DT":"10/31/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","NARRATIVE":"EE WAS ATTEMPTING TO PULL A MANTRIP SEAT FORWARD TO SEE IF THERE WAS A SECTION OF AIR HOSE BEHIND THE SEAT. THE SEAT WAS STUCK AND WHEN HE GAVE IT A HARD TUG THE SEAT QUICKLY SPRANG FORWARD AN D HIS RIGHT MIDDLE FINGER WAS PINCHED BETWEEN THE FRAME OF THE SEAT AND THE END OF THE MANTRIP. THIS RESULTED INTO A FRACTURE TO THE TIP OF HIS RIGHT MIDDLE FINGER.","sourceDate":"2001-10-31"},{"SOURCE_ROW_NUMBER":"178770","DOCUMENT_NO":"220013020154","ACCIDENT_DT":"10/13/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"32","NARRATIVE":"EE WAS REPAIRING THE WINDSHIELD WIPERS ON TRUCK.HE DROPPED A WRENCH & WHILE DESCENDING THE TRUCKLADDER TO RETRIEVE IT HIS FOOT SLIPPED ON THE BOTTOM STEP CAUSING HIM TO FALL ONTO THE CONRETE F LOOR. HE LANDED ON HIS LEFT SHOULDER. THE INJURYHAS INITIALLY BEEN DIAGNOSED AS AN ACUTE SPRAIN.","sourceDate":"2001-10-13"},{"SOURCE_ROW_NUMBER":"260598","DOCUMENT_NO":"220012950078","ACCIDENT_DT":"10/04/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Flash burns (electric)","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"16","NARRATIVE":"EE WAS REACHING IN THE DECK OF A BATTERY CAR TO GET A SAFETY CHAIN THAT WAS TO BE INSTALLED BETWEEN THE BATTERY CAR AND A 15 TON MOTOR. IN DOING SO HE CONTACTED A CABLE THAT WAS PART OF THE WI RING CIRCUIT FOR AN EMERGENCY STOP BUTTON ON THAT BATTERY CAR. IT APPEARS THERE MUST HAVE BEEN A BARE PLACE IN THAT CABLE, AND WHEN HE CONTACTED THAT CABLE HE PUSHED IT AGAINST THE METAL FRAM","sourceDate":"2001-10-04"},{"SOURCE_ROW_NUMBER":"148689","DOCUMENT_NO":"220012600123","ACCIDENT_DT":"09/02/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"INJURED AND ANOTHER EE WERE REMOVING THE CLUTCH ROTOR FROM THE OVERHEAD HOIST LOCATED IN THE G4 STATION OF THE 10 MILE OVERLAND CONVEYER. WHEN HE PULLED THE ROTOR OUT OF THE CLUTCH HE LOST CO NTROL OF IT AND HIS LEFT LITTLE FINGER WAS PINCHED BETWEEN THE ROTOR AND CLUTCH HOUSING. THIS RESULTED INTO A LACERATION THAT REQUIRED 7 SUTURES TO CLOSE.","sourceDate":"2001-09-02"},{"SOURCE_ROW_NUMBER":"32587","DOCUMENT_NO":"220012600121","ACCIDENT_DT":"09/01/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL HAS OCCURRED IN THE SOUTH MAINS A BELT AND TRACK ENTRY IN THE AREA OF SURVEY STATION NO 9871. THE FALL IS APPROX 24 FT WIDE BY 100 FT LONG AND IN EXCESS OF 15 FT HIGH. THE MATERIAL S IN THE FALL CONSISTED OF MOSTLY LIMESTONE AND SHALE. A VARIETY OF ROOF SUPPORTS HAD BEEN USED IN THIS AREA INCLUDING SEVERAL DIFFERENT LENGTH OF RESIN GROUTED BOLTS AND ROOF GROUTING.","sourceDate":"2001-09-01"},{"SOURCE_ROW_NUMBER":"170169","DOCUMENT_NO":"220012600119","ACCIDENT_DT":"08/29/2001","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A ROOF FALL HAS OCCURRED IN THE TAILGATE ENTRY OF THE CS LONGWALL SECTION NEAR THE 1600 FEET MARKER. THE FALL WAS APPROX 30 FT LONG BY 20 FT WIDE AND UP TO 5 1/2 FT HIGH. THE FALL MATERIAL CON SISTED OF LIMESTONE. THE AREA ROOF HAD BEEN SUPPORTED BY 4 FT LONG RESIN BOLTS AND \"SUPERPOSTS\".","sourceDate":"2001-08-29"},{"SOURCE_ROW_NUMBER":"217493","DOCUMENT_NO":"220012470145","ACCIDENT_DT":"08/23/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"EE WAS PULLING THE SHIELD ON THE C-5 LONGWALL FACE WHEN HE REACHED FOR THE CONTROLS THAT OPERATES THE SHIELD FUNCTIONS, A SHIELD TO SHIELD HIGHTPRESSURE HOSE BURST, SPRAYING EMULSION ON EE. EE SAID THE HOSE DID NOT STRIKE HIM HOWEVER, THE PRESSURE OF THE EMULSION CAUSED HIM TO BE KNOCKED TO FLOOR & HIS LEFT KNEE STRUCK A RELAY BAR THIS RESULTED IN FRACTURE TO LEFT PATELLA","sourceDate":"2001-08-23"},{"SOURCE_ROW_NUMBER":"109690","DOCUMENT_NO":"220012470144","ACCIDENT_DT":"08/13/2001","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Longwall operator, Chock operator, Shear operator, Plow operator","NO_INJURIES":"1","DAYS_LOST":"75","NARRATIVE":"EE WAS ASSISTING ANOTHER EE IN LIFTING A RAM JACK THAT WAS LYING ON THE MINE FLOOR BETWEEN THE SHIELDS &FACE. A CHAIN WAS PLACED IN THE EYE OF THE JACK & BOTH EE'S ATTEMPTED TO LIFT IT ONTO THE PONTOONS. IT WAS DURING THAT TIME THAT INJ EE SAID HE EXPERIENCED A BURNING SENSATION IN HIS BACK","sourceDate":"2001-08-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2001-10-24","lastDate":"2001-10-24","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":261,"firstDate":"2000-01-04","lastDate":"2026-07-28","metrics":{"ss":110,"delinquent":259,"recentRows":30,"paidPenalty":38850,"proposedPenalty":41386,"currentAssessment":39001},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2973862","VIOLATION_NO":"5029875","ISSUE_DT":"07/28/2026","CFR_STANDARD_CD":"50.20-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Printed","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"1923659","VIOLATION_NO":"5022937","ISSUE_DT":"03/16/2026","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"1931551","VIOLATION_NO":"5025750","ISSUE_DT":"07/28/2025","CFR_STANDARD_CD":"77.1707(b)(8)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"151.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"1931550","VIOLATION_NO":"5025749","ISSUE_DT":"07/28/2025","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"883.00","CURRENT_ASSESSMENT_AMT":"151.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"2903711","VIOLATION_NO":"9589057","ISSUE_DT":"10/01/2024","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-10-01"},{"SOURCE_ROW_NUMBER":"2903710","VIOLATION_NO":"9589056","ISSUE_DT":"10/01/2024","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-10-01"},{"SOURCE_ROW_NUMBER":"2903702","VIOLATION_NO":"9587394","ISSUE_DT":"08/12/2024","CFR_STANDARD_CD":"77.216-3(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"2903701","VIOLATION_NO":"9587393","ISSUE_DT":"08/12/2024","CFR_STANDARD_CD":"77.216-3(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"172.00","CURRENT_ASSESSMENT_AMT":"172.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"2903700","VIOLATION_NO":"9587392","ISSUE_DT":"08/12/2024","CFR_STANDARD_CD":"77.216-5(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"172.00","CURRENT_ASSESSMENT_AMT":"172.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"2903684","VIOLATION_NO":"9587364","ISSUE_DT":"05/20/2024","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-05-20"},{"SOURCE_ROW_NUMBER":"2903683","VIOLATION_NO":"9587363","ISSUE_DT":"05/20/2024","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-05-20"},{"SOURCE_ROW_NUMBER":"2903682","VIOLATION_NO":"9587362","ISSUE_DT":"05/20/2024","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"147.00","CURRENT_ASSESSMENT_AMT":"147.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2024-05-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":4,"firstDate":"2003-01-15","lastDate":"2026-03-12","metrics":{"appeals":0,"decisions":4,"recentRows":3,"decisionPenalty":792,"originalPenalty":3177},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"460050","VIOLATION_NO":"5025749","DOCKET_NO":"LAKE 2025-0339","DECISION_DT":"03/12/2026","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"883.00","DECISION_PENALTY_AMT":"151.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2026-03-12"},{"SOURCE_ROW_NUMBER":"454306","VIOLATION_NO":"9589056","DOCKET_NO":"LAKE 2025-0088","DECISION_DT":"02/18/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"147.00","DECISION_PENALTY_AMT":"147.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-02-18"},{"SOURCE_ROW_NUMBER":"453041","VIOLATION_NO":"9589057","DOCKET_NO":"LAKE 2025-0088","DECISION_DT":"02/18/2025","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"147.00","DECISION_PENALTY_AMT":"147.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2025-02-18"},{"SOURCE_ROW_NUMBER":"476493","VIOLATION_NO":"7134882","DOCKET_NO":"LAKE20030019","DECISION_DT":"01/15/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"347.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2003-01-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":500,"firstDate":"2000-01-04","lastDate":"2026-07-13","metrics":{"recentRows":14,"cpdmSamples":0,"voidSamples":61,"validSamples":439,"maxConcentration":10.438,"concentrationTotal":325.763},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1583006","CASS_NUM":"58542683","SMP_TAKEN_DT":"7/13/2026","CONC":".06","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"1384474","CASS_NUM":"58542680","SMP_TAKEN_DT":"7/13/2026","CONC":".026","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"1298716","CASS_NUM":"58542907","SMP_TAKEN_DT":"7/13/2026","CONC":".022","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"636394","CASS_NUM":"58543196","SMP_TAKEN_DT":"7/13/2026","CONC":".119","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"34341","CASS_NUM":"58542900","SMP_TAKEN_DT":"7/13/2026","CONC":".028","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-07-13"},{"SOURCE_ROW_NUMBER":"1073091","CASS_NUM":"58538105","SMP_TAKEN_DT":"3/16/2026","CONC":".274","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"811559","CASS_NUM":"58538131","SMP_TAKEN_DT":"3/16/2026","CONC":".035","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"487701","CASS_NUM":"58538113","SMP_TAKEN_DT":"3/16/2026","CONC":".021","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"95775","CASS_NUM":"58538120","SMP_TAKEN_DT":"3/16/2026","CONC":".031","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"1411370","CASS_NUM":"58553136","SMP_TAKEN_DT":"7/28/2025","CONC":".011","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"1367063","CASS_NUM":"58553140","SMP_TAKEN_DT":"7/28/2025","CONC":".071","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"583322","CASS_NUM":"58553130","SMP_TAKEN_DT":"7/28/2025","CONC":".054","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"MALFUNCTIONING PUMP","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2025-07-28"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":23,"firstDate":"2000-02-09","lastDate":"2025-01-03","metrics":{"linkedIssuances":23},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":3,"firstDate":"2024-10-01","lastDate":"2025-07-28","metrics":{"decisions":3,"ssChanged":1,"recentRows":3,"decisionPenalty":445,"proposedPenalty":1177},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"54420","CITATION_NO":"5025749","CITATION_ISSUE_DT":"07/28/2025","DOCKET_NO":"LAKE 2025-0339","DECISION_DT":"03/12/2026","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"883.00","DECISION_PENALTY_AMT":"151.00","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"448052","CITATION_NO":"9589056","CITATION_ISSUE_DT":"10/01/2024","DOCKET_NO":"LAKE 2025-0088","DECISION_DT":"02/18/2025","CFR_STANDARD_CODE":"77.410(c)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"147.00","DECISION_PENALTY_AMT":"147.00","sourceDate":"2024-10-01"},{"SOURCE_ROW_NUMBER":"221224","CITATION_NO":"9589057","CITATION_ISSUE_DT":"10/01/2024","DOCKET_NO":"LAKE 2025-0088","DECISION_DT":"02/18/2025","CFR_STANDARD_CODE":"77.208(e)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"147.00","DECISION_PENALTY_AMT":"147.00","sourceDate":"2024-10-01"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":353,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":85,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"1950-01-01","lastDate":"2013-12-06","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":216,"firstDate":"2000-01-03","lastDate":"2026-07-09","metrics":{"inspectors":319,"recentRows":32,"onSiteHours":3631.25,"inspectionHours":6498.75,"inspectionSamples":28},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1094117","EVENT_NO":"F015C7A","INSPECTION_BEGIN_DT":"07/09/2026","INSPECTION_END_DT":"08/10/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"112.25","SUM_TOTAL_ON_SITE_HOURS":"56","sourceDate":"2026-07-09"},{"SOURCE_ROW_NUMBER":"1130294","EVENT_NO":"F02AF45","INSPECTION_BEGIN_DT":"06/22/2026","INSPECTION_END_DT":"06/24/2026","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27.25","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2026-06-22"},{"SOURCE_ROW_NUMBER":"719163","EVENT_NO":"F02AF3B","INSPECTION_BEGIN_DT":"04/21/2026","INSPECTION_END_DT":"04/23/2026","ACTIVITY_CODE":"E24","ACTIVITY":"Other Technical Compliance Investigations","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2026-04-21"},{"SOURCE_ROW_NUMBER":"110501","EVENT_NO":"6320831","INSPECTION_BEGIN_DT":"02/27/2026","INSPECTION_END_DT":"03/25/2026","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"113.5","SUM_TOTAL_ON_SITE_HOURS":"53.25","sourceDate":"2026-02-27"},{"SOURCE_ROW_NUMBER":"242855","EVENT_NO":"F01551D","INSPECTION_BEGIN_DT":"11/17/2025","INSPECTION_END_DT":"11/18/2025","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2025-11-17"},{"SOURCE_ROW_NUMBER":"141498","EVENT_NO":"F01550F","INSPECTION_BEGIN_DT":"08/27/2025","INSPECTION_END_DT":"08/28/2025","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"26.25","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2025-08-27"},{"SOURCE_ROW_NUMBER":"680529","EVENT_NO":"6322950","INSPECTION_BEGIN_DT":"07/16/2025","INSPECTION_END_DT":"08/05/2025","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"81.5","SUM_TOTAL_ON_SITE_HOURS":"44.5","sourceDate":"2025-07-16"},{"SOURCE_ROW_NUMBER":"758188","EVENT_NO":"F015506","INSPECTION_BEGIN_DT":"07/14/2025","INSPECTION_END_DT":"07/15/2025","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"25.25","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2025-07-14"},{"SOURCE_ROW_NUMBER":"1138904","EVENT_NO":"F014008","INSPECTION_BEGIN_DT":"04/22/2025","INSPECTION_END_DT":"04/23/2025","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27.75","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2025-04-22"},{"SOURCE_ROW_NUMBER":"404664","EVENT_NO":"F00F217","INSPECTION_BEGIN_DT":"03/18/2025","INSPECTION_END_DT":"03/19/2025","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27.75","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2025-03-18"},{"SOURCE_ROW_NUMBER":"7876","EVENT_NO":"F0007AB","INSPECTION_BEGIN_DT":"01/15/2025","INSPECTION_END_DT":"01/16/2025","ACTIVITY_CODE":"E24","ACTIVITY":"Other Technical Compliance Investigations","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2025-01-15"},{"SOURCE_ROW_NUMBER":"185827","EVENT_NO":"F00F209","INSPECTION_BEGIN_DT":"11/20/2024","INSPECTION_END_DT":"11/21/2024","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2024-11-20"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":318,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2026-Q2":{"hours":0,"employees":0,"production":0},"2026-Q1":{"hours":0,"employees":0,"production":0},"2025-Q4":{"hours":0,"employees":0,"production":0},"2025-Q3":{"hours":0,"employees":0,"production":0},"2025-Q2":{"hours":0,"employees":0,"production":0},"2025-Q1":{"hours":0,"employees":0,"production":0},"2024-Q4":{"hours":0,"employees":0,"production":0},"2024-Q3":{"hours":0,"employees":0,"production":0},"2024-Q2":{"hours":0,"employees":0,"production":0},"2024-Q1":{"hours":0,"employees":0,"production":0},"2023-Q4":{"hours":0,"employees":0,"production":0},"2023-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":36,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":15271,"employees":7,"production":0},"2008":{"hours":14305,"employees":7,"production":0},"2009":{"hours":12760,"employees":6,"production":0},"2010":{"hours":10128,"employees":8,"production":0},"2011":{"hours":10233,"employees":5,"production":0},"2012":{"hours":10682,"employees":5,"production":0},"2013":{"hours":10604,"employees":5,"production":0},"2014":{"hours":152,"employees":1,"production":0},"2016":{"hours":435,"employees":1,"production":0},"2026":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":88,"firstDate":"2000-02-02","lastDate":"2026-03-16","metrics":{"recentRows":9,"doseOver100":20,"actDoseTotal":12031,"pelDoseTotal":4185},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"127801","EVENT_NO":"6320831","SURVEY_DATE":"03/16/2026","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"13","ACT_DOSE_85":"58","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"127800","EVENT_NO":"6320831","SURVEY_DATE":"03/16/2026","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"13","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"127799","EVENT_NO":"6320831","SURVEY_DATE":"03/16/2026","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"27","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"127798","EVENT_NO":"6320831","SURVEY_DATE":"03/16/2026","OCCUPATION_CD_DESC":"ROTARY BUCKET EXCAVATOR OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"127806","EVENT_NO":"6322950","SURVEY_DATE":"08/04/2025","OCCUPATION_CD_DESC":"ROAD GRADER OPERATOR","MACHINE_CD":"28","ACT_DOSE_85":"51","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2025-08-04"},{"SOURCE_ROW_NUMBER":"127805","EVENT_NO":"6322950","SURVEY_DATE":"08/04/2025","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"24","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2025-08-04"},{"SOURCE_ROW_NUMBER":"127804","EVENT_NO":"6322950","SURVEY_DATE":"08/04/2025","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","ACT_DOSE_85":"22","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2025-08-04"},{"SOURCE_ROW_NUMBER":"127803","EVENT_NO":"6322950","SURVEY_DATE":"08/04/2025","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","ACT_DOSE_85":"23","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2025-08-04"},{"SOURCE_ROW_NUMBER":"127802","EVENT_NO":"6322950","SURVEY_DATE":"08/04/2025","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","ACT_DOSE_85":"14","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2025-08-04"},{"SOURCE_ROW_NUMBER":"127797","EVENT_NO":"6276426","SURVEY_DATE":"08/16/2018","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"33","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2018-08-16"},{"SOURCE_ROW_NUMBER":"127796","EVENT_NO":"6272885","SURVEY_DATE":"03/24/2016","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"21","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2016-03-24"},{"SOURCE_ROW_NUMBER":"127795","EVENT_NO":"6268879","SURVEY_DATE":"09/02/2015","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"38","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2015-09-02"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":20,"firstDate":"2000-02-01","lastDate":"2001-05-07","metrics":{"recentRows":0,"voidSamples":4,"maxQuartzPct":13.2,"validSamples":16,"quartzPctTotal":93.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"56751","CASSETTE_NO":"57342500","SAMPLE_DT":"05/07/2001","QUARTZ_PCT":"01.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-05-07"},{"SOURCE_ROW_NUMBER":"29407","CASSETTE_NO":"57304721","SAMPLE_DT":"03/27/2001","QUARTZ_PCT":"09.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-27"},{"SOURCE_ROW_NUMBER":"160875","CASSETTE_NO":"50573835","SAMPLE_DT":"03/09/2001","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-03-09"},{"SOURCE_ROW_NUMBER":"111324","CASSETTE_NO":"50573837","SAMPLE_DT":"03/09/2001","QUARTZ_PCT":"08.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-03-09"},{"SOURCE_ROW_NUMBER":"39122","CASSETTE_NO":"50573860","SAMPLE_DT":"02/14/2001","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-02-14"},{"SOURCE_ROW_NUMBER":"18596","CASSETTE_NO":"50573872","SAMPLE_DT":"02/14/2001","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2001-02-14"},{"SOURCE_ROW_NUMBER":"162083","CASSETTE_NO":"57304646","SAMPLE_DT":"01/25/2001","QUARTZ_PCT":"07.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-25"},{"SOURCE_ROW_NUMBER":"55344","CASSETTE_NO":"57304709","SAMPLE_DT":"01/25/2001","QUARTZ_PCT":"07.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-25"},{"SOURCE_ROW_NUMBER":"96915","CASSETTE_NO":"57304746","SAMPLE_DT":"01/24/2001","QUARTZ_PCT":"00.4","OCC_CODE_DESC":"LONGWALL(RETURN-SIDE FACE WORKER)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2001-01-24"},{"SOURCE_ROW_NUMBER":"35437","CASSETTE_NO":"57304758","SAMPLE_DT":"10/23/2000","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-10-23"},{"SOURCE_ROW_NUMBER":"22913","CASSETTE_NO":"50543134","SAMPLE_DT":"10/19/2000","QUARTZ_PCT":"00.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2000-10-19"},{"SOURCE_ROW_NUMBER":"157995","CASSETTE_NO":"50543094","SAMPLE_DT":"09/20/2000","QUARTZ_PCT":"01.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2000-09-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":266,"firstDate":"2000-01-04","lastDate":"2026-07-28","metrics":{"ss":110,"amountDue":39001,"contested":1,"amountPaid":38850,"recentRows":30,"section104d":0,"unterminated":0,"proposedPenalty":41386},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1739067","VIOLATION_NO":"5029875","VIOLATION_ISSUE_DT":"07/28/2026","SIG_SUB":"N","PART_SECTION":"50.20-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/28/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2026-07-28"},{"SOURCE_ROW_NUMBER":"1738959","VIOLATION_NO":"5022937","VIOLATION_ISSUE_DT":"03/16/2026","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/16/2026","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2026-03-16"},{"SOURCE_ROW_NUMBER":"1739069","VIOLATION_NO":"5025750","VIOLATION_ISSUE_DT":"07/28/2025","SIG_SUB":"N","PART_SECTION":"77.1707(b)(8)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/30/2025","PROPOSED_PENALTY":"151","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"1739068","VIOLATION_NO":"5025749","VIOLATION_ISSUE_DT":"07/28/2025","SIG_SUB":"N","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/30/2025","PROPOSED_PENALTY":"883","AMOUNT_DUE":"151","AMOUNT_PAID":"151","CONTESTED_IND":"N","sourceDate":"2025-07-28"},{"SOURCE_ROW_NUMBER":"1739116","VIOLATION_NO":"9589057","VIOLATION_ISSUE_DT":"10/01/2024","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/01/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-10-01"},{"SOURCE_ROW_NUMBER":"1739115","VIOLATION_NO":"9589056","VIOLATION_ISSUE_DT":"10/01/2024","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/09/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-10-01"},{"SOURCE_ROW_NUMBER":"1739076","VIOLATION_NO":"9587394","VIOLATION_ISSUE_DT":"08/12/2024","SIG_SUB":"N","PART_SECTION":"77.216-3(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"1739075","VIOLATION_NO":"9587393","VIOLATION_ISSUE_DT":"08/12/2024","SIG_SUB":"N","PART_SECTION":"77.216-3(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2024","PROPOSED_PENALTY":"172","AMOUNT_DUE":"172","AMOUNT_PAID":"172","CONTESTED_IND":"N","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"1739074","VIOLATION_NO":"9587392","VIOLATION_ISSUE_DT":"08/12/2024","SIG_SUB":"N","PART_SECTION":"77.216-5(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/23/2024","PROPOSED_PENALTY":"172","AMOUNT_DUE":"172","AMOUNT_PAID":"172","CONTESTED_IND":"N","sourceDate":"2024-08-12"},{"SOURCE_ROW_NUMBER":"1739021","VIOLATION_NO":"9587364","VIOLATION_ISSUE_DT":"05/20/2024","SIG_SUB":"N","PART_SECTION":"77.1606(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/20/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-05-20"},{"SOURCE_ROW_NUMBER":"1739020","VIOLATION_NO":"9587363","VIOLATION_ISSUE_DT":"05/20/2024","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/28/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-05-20"},{"SOURCE_ROW_NUMBER":"1739019","VIOLATION_NO":"9587362","VIOLATION_ISSUE_DT":"05/20/2024","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/04/2024","PROPOSED_PENALTY":"147","AMOUNT_DUE":"147","AMOUNT_PAID":"147","CONTESTED_IND":"N","sourceDate":"2024-05-20"}]}],"safety":{"href":"/api/v1/mines/3301172/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/3301172/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"General instructions for completing MSHA Form 7000-1.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-C/section-50.20-1","part":"50","subchapter":"I","subpart":"C","id":"50.20-1","citation":"30 CFR 50.20-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","heading":"First aid equipment; location; minimum requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1707","part":"77","subchapter":"O","subpart":"R","id":"77.1707","citation":"30 CFR 77.1707","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Water, sediment, or slurry impoundments and impounding structures; inspection requirements; correction of hazards; program requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.216-3","part":"77","subchapter":"O","subpart":"C","id":"77.216-3","citation":"30 CFR 77.216-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","heading":"Water, sediment or slurry impoundments and impounding structures; abandonment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.216-5","part":"77","subchapter":"O","subpart":"C","id":"77.216-5","citation":"30 CFR 77.216-5","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"3301172","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}