{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"2400108","name":"Big Sky","status":"Abandoned","status_date":"2008-01-30","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"MT","county":"Rosebud","nearest_town":"Colstrip","operator_id":"P24170","operator_name":"Big Sky Coal Company","controller_id":"C15833","controller_name":"Peabody Energy Corporation","district":"C09","office":"Gillette WY Field Office","employees":0,"latitude":45.854444,"longitude":-106.616666},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":311},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"2400108","name":"Big Sky"},"operator":{"type":"operator","id":"P24170","name":"Big Sky Coal Company"},"controller":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P01154","name":"Peabody Coal Company"},"object":{"type":"mine","id":"2400108","name":"Big Sky"},"validFrom":"1950-01-01","validTo":"1977-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|P01154|1950-01-01|1977-06-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00991","name":"Kennecott Copper Corp"},"object":{"type":"mine","id":"2400108","name":"Big Sky"},"validFrom":"1950-01-01","validTo":"1977-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|C00991|1950-01-01|1977-06-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00991","name":"Kennecott Copper Corp"},"object":{"type":"operator","id":"P01154","name":"Peabody Coal Company"},"validFrom":"1950-01-01","validTo":"1977-06-30","current":false,"derived":true,"evidenceMineId":"2400108","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|P01154|1950-01-01|C00991|1950-01-01|51469"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22011","name":"Big Sky Coal Company"},"object":{"type":"mine","id":"2400108","name":"Big Sky"},"validFrom":"1977-07-01","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|P22011|1977-07-01|1998-05-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"mine","id":"2400108","name":"Big Sky"},"validFrom":"1977-07-01","validTo":"1998-05-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|C05313|1977-07-01|1998-05-18"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05313","name":"Hanson PLC"},"object":{"type":"operator","id":"P22011","name":"Big Sky Coal Company"},"validFrom":"1977-07-01","validTo":"1998-05-18","current":false,"derived":true,"evidenceMineId":"2400108","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|P22011|1977-07-01|C05313|1977-07-01|68303"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24170","name":"Big Sky Coal Company"},"object":{"type":"mine","id":"2400108","name":"Big Sky"},"validFrom":"1998-05-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|P24170|1998-05-19|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"mine","id":"2400108","name":"Big Sky"},"validFrom":"1998-05-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|C15833|1998-05-19|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15833","name":"Peabody Energy Corporation"},"object":{"type":"operator","id":"P24170","name":"Big Sky Coal Company"},"validFrom":"1998-05-19","validTo":null,"current":true,"derived":true,"evidenceMineId":"2400108","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"2400108|P24170|1998-05-19|C15833|1998-05-19|96975"}}],"coverage":{"historyRecords":3,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":5,"firstDate":"2000-07-12","lastDate":"2004-04-28","metrics":{"daysLost":77,"injuries":5,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"143871","DOCUMENT_NO":"220041250012","ACCIDENT_DT":"04/28/2004","DEGREE_INJURY":"INJURIES DUE TO NATURAL CAUSES","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"DECEASED WAS FOUND UNRESPONSIVE - LYING DOWN HALF IN THE GREASE ROOM AND HALF ON THE SHOE.","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"178337","DOCUMENT_NO":"220032620024","ACCIDENT_DT":"05/23/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"76","NARRATIVE":"ON 5-23-03 IT WAS REPORTED THAT EE (MECHANNIC ON SHIFT) AND ANOTHER EE WERE SETTING IN #598D-11 CAT DOZER ENGINE, ATTACHED TO A 35TON P&H CRANE EE STATED THE CRANE HAD THE DOZER ENGINE A COUPL E OF INCHES FROM SETTING IN ENGINE MOUNTS. EE PRIED ON THE RIGHT KNEE WITH THE PRY BAR. IN THE PROCESS ENGINE SLIPPED INTO PLACE HITTING HIM IN RIGHT KNEE WITH THE PRY BAR. NO LOST TIME.","sourceDate":"2003-05-23"},{"SOURCE_ROW_NUMBER":"251477","DOCUMENT_NO":"220012690011","ACCIDENT_DT":"09/18/2001","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"IT WAS REPORTED, THAT EE MECHANIC ON 1ST SHIFT WAS USING SHOP DRILL PRESS AND DRILLING OUT HOLE ON DMM OVERBURDEN DRILL HYDRAULIC MOTOR BRACKET. HE HAD A HOLD OF THE PUMP AND STARTED TO USE DR ILL PRESS WITH 1/2\" DRILL BIT. THE PUMP STUCK ONDRILL BIT AND SPUN. THE LEFT THUMB CONTACTED THE DRILL BIT AND CAUSED A LACERATION, WHICH REQUIRED SIX STITCHES. SIX STITCHES WERE REQUIRED TO","sourceDate":"2001-09-18"},{"SOURCE_ROW_NUMBER":"92151","DOCUMENT_NO":"220012280055","ACCIDENT_DT":"08/06/2001","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Truck driver","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"TRUCK DRIVER WAS MOVING ROLLER BARS ON HIS TRAILER WHEN ROLLERS SHIFTED AND CRUSHED RIGHT LITTLE FINGER TIP. FIRST JOINT WAS CUT OFF. ROLLERS WERE BANDED TOGETHER WITH PLASTIC BANDS & THEY BRO KE, CAUSING THE ROLLERS TO SHIFT.","sourceDate":"2001-08-06"},{"SOURCE_ROW_NUMBER":"32129","DOCUMENT_NO":"220002020049","ACCIDENT_DT":"07/12/2000","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","NARRATIVE":"IT WAS REPORTED THAT EMPLOYEE WAS USING AN AIR IMPACT WRENCH ON 1260 DRAGLINE HOIST DRUM CLAMP BOLT AND NUT. A PIECE OF WELDING ROD STOCK WAS PLACED THROUGH AIR SOCKET TO ONTO AIR WRENCH FITTI NG AND WAS TAPED. THE PIECE OF WELDING ROD POKEDTHROUGH ONE END OF THE TAPE. HE ENGAGED THE AIR IMPACT WRENCH AND A PIECE OF METAL STICKING OUT LACERATED RIGHT INDEX FINGER. 6 STITCHES.","sourceDate":"2000-07-12"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2008-01-30","lastDate":"2008-01-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":25,"firstDate":"2000-05-16","lastDate":"2004-03-01","metrics":{"ss":6,"delinquent":25,"recentRows":0,"paidPenalty":2996,"proposedPenalty":2996,"currentAssessment":2996},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1249921","VIOLATION_NO":"7607009","ISSUE_DT":"03/01/2004","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-01"},{"SOURCE_ROW_NUMBER":"1235549","VIOLATION_NO":"7612930","ISSUE_DT":"07/18/2003","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1235548","VIOLATION_NO":"7612929","ISSUE_DT":"07/18/2003","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1235545","VIOLATION_NO":"7612627","ISSUE_DT":"07/18/2003","CFR_STANDARD_CD":"77.410(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1235544","VIOLATION_NO":"7612626","ISSUE_DT":"07/18/2003","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1235547","VIOLATION_NO":"7612928","ISSUE_DT":"07/17/2003","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"715.00","CURRENT_ASSESSMENT_AMT":"715.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-17"},{"SOURCE_ROW_NUMBER":"1235546","VIOLATION_NO":"7612927","ISSUE_DT":"07/16/2003","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"371.00","CURRENT_ASSESSMENT_AMT":"371.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-07-16"},{"SOURCE_ROW_NUMBER":"1634245","VIOLATION_NO":"3245172","ISSUE_DT":"08/28/2002","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-28"},{"SOURCE_ROW_NUMBER":"1634244","VIOLATION_NO":"3245171","ISSUE_DT":"08/28/2002","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-28"},{"SOURCE_ROW_NUMBER":"1634243","VIOLATION_NO":"3245170","ISSUE_DT":"08/28/2002","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-28"},{"SOURCE_ROW_NUMBER":"1634242","VIOLATION_NO":"3245169","ISSUE_DT":"08/22/2002","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-22"},{"SOURCE_ROW_NUMBER":"1634241","VIOLATION_NO":"3245168","ISSUE_DT":"08/21/2002","CFR_STANDARD_CD":"77.1607(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-08-21"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":50,"firstDate":"2000-05-16","lastDate":"2004-07-28","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":50,"maxConcentration":1.271,"concentrationTotal":10.613},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"280211","CASS_NUM":"57496122","SMP_TAKEN_DT":"7/28/2004","CONC":".069","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"261235","CASS_NUM":"57496133","SMP_TAKEN_DT":"7/28/2004","CONC":".151","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCRAPPER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"217137","CASS_NUM":"57496188","SMP_TAKEN_DT":"7/28/2004","CONC":".2","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"GROUNDMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"404654","CASS_NUM":"50333791","SMP_TAKEN_DT":"10/16/2003","CONC":".11","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WELDER (NON-SHOP)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-10-16"},{"SOURCE_ROW_NUMBER":"104522","CASS_NUM":"50333792","SMP_TAKEN_DT":"9/9/2003","CONC":".11","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WELDER (NON-SHOP)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-09-09"},{"SOURCE_ROW_NUMBER":"1528076","CASS_NUM":"57512834","SMP_TAKEN_DT":"7/18/2003","CONC":".417","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1076622","CASS_NUM":"57512835","SMP_TAKEN_DT":"7/18/2003","CONC":".322","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1069373","CASS_NUM":"57512844","SMP_TAKEN_DT":"7/18/2003","CONC":".361","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"431670","CASS_NUM":"57512771","SMP_TAKEN_DT":"7/18/2003","CONC":".154","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"124605","CASS_NUM":"57512807","SMP_TAKEN_DT":"7/18/2003","CONC":".092","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"TIPPLE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"330373","CASS_NUM":"50333879","SMP_TAKEN_DT":"7/2/2003","CONC":".168","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WELDER (NON-SHOP)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-07-02"},{"SOURCE_ROW_NUMBER":"1183143","CASS_NUM":"50333869","SMP_TAKEN_DT":"4/22/2003","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WELDER (NON-SHOP)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2003-04-22"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":11,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1950-01-01","lastDate":"1998-05-19","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":43,"firstDate":"2000-05-11","lastDate":"2008-03-06","metrics":{"inspectors":41,"recentRows":0,"onSiteHours":319.5,"inspectionHours":675.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"754509","EVENT_NO":"4266581","INSPECTION_BEGIN_DT":"03/06/2008","INSPECTION_END_DT":"03/10/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2008-03-06"},{"SOURCE_ROW_NUMBER":"474289","EVENT_NO":"4267209","INSPECTION_BEGIN_DT":"08/14/2007","INSPECTION_END_DT":"08/14/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2007-08-14"},{"SOURCE_ROW_NUMBER":"65031","EVENT_NO":"4266777","INSPECTION_BEGIN_DT":"09/06/2006","INSPECTION_END_DT":"09/08/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2006-09-06"},{"SOURCE_ROW_NUMBER":"498095","EVENT_NO":"4475355","INSPECTION_BEGIN_DT":"03/16/2006","INSPECTION_END_DT":"03/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"382240","EVENT_NO":"4266548","INSPECTION_BEGIN_DT":"07/25/2005","INSPECTION_END_DT":"07/27/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2005-07-25"},{"SOURCE_ROW_NUMBER":"556778","EVENT_NO":"4266625","INSPECTION_BEGIN_DT":"03/28/2005","INSPECTION_END_DT":"03/29/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-03-28"},{"SOURCE_ROW_NUMBER":"844670","EVENT_NO":"4266395","INSPECTION_BEGIN_DT":"07/27/2004","INSPECTION_END_DT":"07/29/2004","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-07-27"},{"SOURCE_ROW_NUMBER":"423748","EVENT_NO":"4266396","INSPECTION_BEGIN_DT":"07/27/2004","INSPECTION_END_DT":"08/05/2004","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-07-27"},{"SOURCE_ROW_NUMBER":"50269","EVENT_NO":"4266394","INSPECTION_BEGIN_DT":"07/27/2004","INSPECTION_END_DT":"07/29/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-07-27"},{"SOURCE_ROW_NUMBER":"992651","EVENT_NO":"4266372","INSPECTION_BEGIN_DT":"04/28/2004","INSPECTION_END_DT":"07/21/2004","ACTIVITY_CODE":"AFA","ACTIVITY":"FATAL ACCIDENT INVESTIGATION","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"67.5","SUM_TOTAL_ON_SITE_HOURS":"17","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"569256","EVENT_NO":"4276513","INSPECTION_BEGIN_DT":"03/01/2004","INSPECTION_END_DT":"03/01/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2004-03-01"},{"SOURCE_ROW_NUMBER":"549795","EVENT_NO":"4266087","INSPECTION_BEGIN_DT":"09/02/2003","INSPECTION_END_DT":"09/08/2003","ACTIVITY_CODE":"CBA","ACTIVITY":"ELECTRICAL INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"29","SUM_TOTAL_ON_SITE_HOURS":"17","sourceDate":"2003-09-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":99,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008-Q1":{"hours":660,"employees":1,"production":0},"2007-Q4":{"hours":1684,"employees":3,"production":0},"2007-Q3":{"hours":4066,"employees":9,"production":0},"2007-Q2":{"hours":4675,"employees":10,"production":0},"2007-Q1":{"hours":5867,"employees":14,"production":0},"2006-Q4":{"hours":6863,"employees":14,"production":0},"2006-Q3":{"hours":6820,"employees":14,"production":0},"2006-Q2":{"hours":7206,"employees":14,"production":0},"2006-Q1":{"hours":7078,"employees":14,"production":0},"2005-Q4":{"hours":5754,"employees":14,"production":0},"2005-Q3":{"hours":7172,"employees":17,"production":0},"2005-Q2":{"hours":8074,"employees":17,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":17,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":94597,"employees":43,"production":1404205},"2001":{"hours":142667,"employees":61,"production":2592417},"2002":{"hours":154307,"employees":67,"production":2805392},"2003":{"hours":143845,"employees":63,"production":2597358},"2004":{"hours":48506,"employees":26,"production":0},"2005":{"hours":29326,"employees":16,"production":0},"2006":{"hours":27967,"employees":14,"production":0},"2007":{"hours":16292,"employees":9,"production":0},"2008":{"hours":660,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":27,"firstDate":"2000-05-16","lastDate":"2005-07-26","metrics":{"recentRows":0,"doseOver100":3,"actDoseTotal":1014,"pelDoseTotal":553},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"121708","EVENT_NO":"4266548","SURVEY_DATE":"07/26/2005","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"9","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"121707","EVENT_NO":"4266548","SURVEY_DATE":"07/26/2005","OCCUPATION_CD_DESC":"SCRAPPER OPERATOR","MACHINE_CD":"33","MANUFACTURER_CD":"018","ACT_DOSE_85":"30","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"121706","EVENT_NO":"4266548","SURVEY_DATE":"07/26/2005","OCCUPATION_CD_DESC":"SCRAPPER OPERATOR","MACHINE_CD":"33","MANUFACTURER_CD":"018","ACT_DOSE_85":"24","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"121705","EVENT_NO":"4266548","SURVEY_DATE":"07/26/2005","OCCUPATION_CD_DESC":"ROAD GRADER OPERATOR","MACHINE_CD":"28","MANUFACTURER_CD":"018","ACT_DOSE_85":"12","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"121704","EVENT_NO":"4266548","SURVEY_DATE":"07/26/2005","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"28","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"121703","EVENT_NO":"4266395","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"22","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"121702","EVENT_NO":"4266395","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"CRANE OPER/DRAGLINE OPERATOR","MACHINE_CD":"12","MANUFACTURER_CD":"015","ACT_DOSE_85":"14","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"121701","EVENT_NO":"4266395","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"ROAD GRADER OPERATOR","MACHINE_CD":"28","MANUFACTURER_CD":"018","ACT_DOSE_85":"55","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"121700","EVENT_NO":"4266395","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"SCRAPPER OPERATOR","MACHINE_CD":"33","MANUFACTURER_CD":"018","ACT_DOSE_85":"2","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"121699","EVENT_NO":"4266395","SURVEY_DATE":"07/28/2004","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"9","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"121698","EVENT_NO":"4265843","SURVEY_DATE":"02/12/2002","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"24","MANUFACTURER_CD":"018","ACT_DOSE_85":"29","PEL_DOSE_90":"2","SURVEY_TYPE":"F","sourceDate":"2002-02-12"},{"SOURCE_ROW_NUMBER":"121697","EVENT_NO":"4265843","SURVEY_DATE":"01/10/2002","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"15","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2002-01-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":27,"firstDate":"2000-05-16","lastDate":"2004-04-28","metrics":{"ss":6,"amountDue":2996,"contested":0,"amountPaid":2996,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2996},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1454224","VIOLATION_NO":"7609423","VIOLATION_ISSUE_DT":"04/28/2004","SECTION_OF_ACT":"103(k)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/29/2004","CONTESTED_IND":"N","sourceDate":"2004-04-28"},{"SOURCE_ROW_NUMBER":"1454223","VIOLATION_NO":"7607009","VIOLATION_ISSUE_DT":"03/01/2004","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/01/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-03-01"},{"SOURCE_ROW_NUMBER":"1454233","VIOLATION_NO":"7612930","VIOLATION_ISSUE_DT":"07/18/2003","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1454232","VIOLATION_NO":"7612929","VIOLATION_ISSUE_DT":"07/18/2003","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1454229","VIOLATION_NO":"7612627","VIOLATION_ISSUE_DT":"07/18/2003","SIG_SUB":"N","PART_SECTION":"77.410(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1454228","VIOLATION_NO":"7612626","VIOLATION_ISSUE_DT":"07/18/2003","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2003","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2003-07-18"},{"SOURCE_ROW_NUMBER":"1454231","VIOLATION_NO":"7612928","VIOLATION_ISSUE_DT":"07/17/2003","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/17/2003","PROPOSED_PENALTY":"715","AMOUNT_DUE":"715","AMOUNT_PAID":"715","CONTESTED_IND":"N","sourceDate":"2003-07-17"},{"SOURCE_ROW_NUMBER":"1454230","VIOLATION_NO":"7612927","VIOLATION_ISSUE_DT":"07/16/2003","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/16/2003","PROPOSED_PENALTY":"371","AMOUNT_DUE":"371","AMOUNT_PAID":"371","CONTESTED_IND":"N","sourceDate":"2003-07-16"},{"SOURCE_ROW_NUMBER":"1454222","VIOLATION_NO":"7609176","VIOLATION_ISSUE_DT":"02/25/2003","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/25/2003","CONTESTED_IND":"N","sourceDate":"2003-02-25"},{"SOURCE_ROW_NUMBER":"1454240","VIOLATION_NO":"3245172","VIOLATION_ISSUE_DT":"08/28/2002","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/04/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-08-28"},{"SOURCE_ROW_NUMBER":"1454239","VIOLATION_NO":"3245171","VIOLATION_ISSUE_DT":"08/28/2002","SIG_SUB":"Y","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2002","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"N","sourceDate":"2002-08-28"},{"SOURCE_ROW_NUMBER":"1454238","VIOLATION_NO":"3245170","VIOLATION_ISSUE_DT":"08/28/2002","SIG_SUB":"Y","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2002","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"N","sourceDate":"2002-08-28"}]}],"safety":{"href":"/api/v1/mines/2400108/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/2400108/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"2400108","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}