{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1800756","name":"Laoc Strip #1","status":"Abandoned","status_date":"2017-12-05","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"MD","county":"Garrett","nearest_town":"Deer Park","operator_id":"0050701","operator_name":"Laoc Corporation","controller_id":"0129261","controller_name":"Brenda L Shank","district":"C03","office":"Morgantown District","employees":0,"latitude":39.255833,"longitude":-79.456111},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":225},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1800756","name":"Laoc Strip #1"},"operator":{"type":"operator","id":"0050701","name":"Laoc Corporation"},"controller":{"type":"controller","id":"0129261","name":"Brenda L Shank"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050701","name":"Laoc Corporation"},"object":{"type":"mine","id":"1800756","name":"Laoc Strip #1"},"validFrom":"2002-05-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1800756|0050701|2002-05-15|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041031","name":"James G  Shank"},"object":{"type":"mine","id":"1800756","name":"Laoc Strip #1"},"validFrom":"2002-05-15","validTo":"2014-07-06","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1800756|0041031|2002-05-15|2014-07-06"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041031","name":"James G  Shank"},"object":{"type":"operator","id":"0050701","name":"Laoc Corporation"},"validFrom":"2002-05-15","validTo":"2014-07-06","current":false,"derived":true,"evidenceMineId":"1800756","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1800756|0050701|2002-05-15|0041031|2002-05-15|1226"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0129261","name":"Brenda L Shank"},"object":{"type":"mine","id":"1800756","name":"Laoc Strip #1"},"validFrom":"2014-07-07","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1800756|0129261|2014-07-07|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0129261","name":"Brenda L Shank"},"object":{"type":"operator","id":"0050701","name":"Laoc Corporation"},"validFrom":"2014-07-07","validTo":null,"current":true,"derived":true,"evidenceMineId":"1800756","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1800756|0050701|2002-05-15|0129261|2014-07-07|25931"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2005-07-01","lastDate":"2005-07-01","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"108955","DOCUMENT_NO":"220052410060","ACCIDENT_DT":"07/01/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"EXPLOSIVES AND BREAKING AGENTS","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Shot was hooked up to cast. 42 + 67 ms between rows. Held 12' stem on inside of shot, 14' on outside. Shot climbed approx 200' high then went outward hitting equip. & pickup. Face was checked with tape. Holes were checked as loaded. No problem with any holes, all holes looked solid. Employee was hit with flyrock while observing shot.","sourceDate":"2005-07-01"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2017-12-05","lastDate":"2017-12-05","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":22,"firstDate":"2004-07-14","lastDate":"2014-09-24","metrics":{"ss":7,"delinquent":22,"recentRows":0,"paidPenalty":2408,"proposedPenalty":2408,"currentAssessment":2408},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1722750","VIOLATION_NO":"8046928","ISSUE_DT":"09/24/2014","CFR_STANDARD_CD":"77.1103(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"1702587","VIOLATION_NO":"8046586","ISSUE_DT":"02/18/2014","CFR_STANDARD_CD":"71.403(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-18"},{"SOURCE_ROW_NUMBER":"1700978","VIOLATION_NO":"8036430","ISSUE_DT":"01/11/2012","CFR_STANDARD_CD":"77.1109(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-11"},{"SOURCE_ROW_NUMBER":"1679299","VIOLATION_NO":"8029040","ISSUE_DT":"11/08/2010","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-11-08"},{"SOURCE_ROW_NUMBER":"1678566","VIOLATION_NO":"8028681","ISSUE_DT":"07/01/2010","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-07-01"},{"SOURCE_ROW_NUMBER":"1700276","VIOLATION_NO":"8022777","ISSUE_DT":"03/02/2010","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-03-02"},{"SOURCE_ROW_NUMBER":"1678145","VIOLATION_NO":"6610000","ISSUE_DT":"07/14/2009","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-14"},{"SOURCE_ROW_NUMBER":"1674841","VIOLATION_NO":"8015366","ISSUE_DT":"03/23/2009","CFR_STANDARD_CD":"41.20","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-03-23"},{"SOURCE_ROW_NUMBER":"1324456","VIOLATION_NO":"6602806","ISSUE_DT":"11/27/2007","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-11-27"},{"SOURCE_ROW_NUMBER":"720434","VIOLATION_NO":"7112128","ISSUE_DT":"05/15/2007","CFR_STANDARD_CD":"77.1200(k)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-15"},{"SOURCE_ROW_NUMBER":"729195","VIOLATION_NO":"7137317","ISSUE_DT":"01/09/2007","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-09"},{"SOURCE_ROW_NUMBER":"729194","VIOLATION_NO":"7137316","ISSUE_DT":"01/09/2007","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-01-09"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":39,"firstDate":"2004-07-14","lastDate":"2014-09-24","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":38,"maxConcentration":0.77,"concentrationTotal":7.25},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1174046","CASS_NUM":"58142111","SMP_TAKEN_DT":"9/24/2014","CONC":".017","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"154837","CASS_NUM":"58107189","SMP_TAKEN_DT":"2/11/2014","CONC":".039","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-02-11"},{"SOURCE_ROW_NUMBER":"62581","CASS_NUM":"57929201","SMP_TAKEN_DT":"9/15/2011","CONC":".036","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-15"},{"SOURCE_ROW_NUMBER":"873046","CASS_NUM":"57876899","SMP_TAKEN_DT":"11/10/2010","CONC":".015","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-11-10"},{"SOURCE_ROW_NUMBER":"380526","CASS_NUM":"57876863","SMP_TAKEN_DT":"11/10/2010","CONC":".181","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-11-10"},{"SOURCE_ROW_NUMBER":"1542482","CASS_NUM":"57851150","SMP_TAKEN_DT":"7/1/2010","CONC":".429","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-07-01"},{"SOURCE_ROW_NUMBER":"812856","CASS_NUM":"57851070","SMP_TAKEN_DT":"7/1/2010","CONC":".086","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-07-01"},{"SOURCE_ROW_NUMBER":"344410","CASS_NUM":"57851101","SMP_TAKEN_DT":"7/1/2010","CONC":".037","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-07-01"},{"SOURCE_ROW_NUMBER":"970343","CASS_NUM":"57820813","SMP_TAKEN_DT":"3/2/2010","CONC":".1","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-03-02"},{"SOURCE_ROW_NUMBER":"967297","CASS_NUM":"57820839","SMP_TAKEN_DT":"3/2/2010","CONC":".067","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-03-02"},{"SOURCE_ROW_NUMBER":"49767","CASS_NUM":"57820823","SMP_TAKEN_DT":"3/2/2010","CONC":".074","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2010-03-02"},{"SOURCE_ROW_NUMBER":"1213883","CASS_NUM":"57702281","SMP_TAKEN_DT":"7/14/2009","CONC":".014","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-07-14"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":47,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2002-05-15","lastDate":"2002-05-15","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":38,"firstDate":"2003-09-25","lastDate":"2017-09-28","metrics":{"inspectors":44,"recentRows":0,"onSiteHours":325.5,"inspectionHours":560.25,"inspectionSamples":43},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"626444","EVENT_NO":"6266055","INSPECTION_BEGIN_DT":"09/28/2017","INSPECTION_END_DT":"09/28/2017","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2017-09-28"},{"SOURCE_ROW_NUMBER":"481264","EVENT_NO":"6265963","INSPECTION_BEGIN_DT":"03/30/2017","INSPECTION_END_DT":"03/30/2017","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2017-03-30"},{"SOURCE_ROW_NUMBER":"645929","EVENT_NO":"6265689","INSPECTION_BEGIN_DT":"03/30/2016","INSPECTION_END_DT":"03/31/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2016-03-30"},{"SOURCE_ROW_NUMBER":"171270","EVENT_NO":"6265798","INSPECTION_BEGIN_DT":"09/30/2015","INSPECTION_END_DT":"09/30/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2015-09-30"},{"SOURCE_ROW_NUMBER":"720765","EVENT_NO":"6265650","INSPECTION_BEGIN_DT":"06/01/2015","INSPECTION_END_DT":"06/01/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2015-06-01"},{"SOURCE_ROW_NUMBER":"1027180","EVENT_NO":"6265536","INSPECTION_BEGIN_DT":"12/18/2014","INSPECTION_END_DT":"01/06/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2014-12-18"},{"SOURCE_ROW_NUMBER":"921485","EVENT_NO":"6265470","INSPECTION_BEGIN_DT":"09/18/2014","INSPECTION_END_DT":"09/26/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"29","SUM_TOTAL_ON_SITE_HOURS":"16.5","sourceDate":"2014-09-18"},{"SOURCE_ROW_NUMBER":"669281","EVENT_NO":"6265522","INSPECTION_BEGIN_DT":"05/15/2014","INSPECTION_END_DT":"05/15/2014","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2014-05-15"},{"SOURCE_ROW_NUMBER":"798674","EVENT_NO":"6259577","INSPECTION_BEGIN_DT":"12/18/2013","INSPECTION_END_DT":"03/06/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2013-12-18"},{"SOURCE_ROW_NUMBER":"206744","EVENT_NO":"6259567","INSPECTION_BEGIN_DT":"10/09/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2013-10-09"},{"SOURCE_ROW_NUMBER":"998828","EVENT_NO":"6259476","INSPECTION_BEGIN_DT":"01/04/2013","INSPECTION_END_DT":"01/04/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2013-01-04"},{"SOURCE_ROW_NUMBER":"772966","EVENT_NO":"6259469","INSPECTION_BEGIN_DT":"09/05/2012","INSPECTION_END_DT":"09/05/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2012-09-05"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":26929,"employees":15,"production":131698},"2007":{"hours":12645,"employees":8,"production":53724},"2008":{"hours":3649,"employees":3,"production":60148},"2009":{"hours":1887,"employees":3,"production":16326},"2010":{"hours":3943,"employees":4,"production":48328},"2011":{"hours":6782,"employees":5,"production":33760},"2012":{"hours":2763,"employees":3,"production":13119},"2013":{"hours":1640,"employees":1,"production":12347},"2014":{"hours":2530,"employees":2,"production":10297},"2015":{"hours":1789,"employees":2,"production":8309}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":27,"firstDate":"2004-07-14","lastDate":"2014-09-24","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":858,"pelDoseTotal":308},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"119800","EVENT_NO":"6265470","SURVEY_DATE":"09/24/2014","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"6","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"119799","EVENT_NO":"6259577","SURVEY_DATE":"01/11/2014","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"14","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2014-01-11"},{"SOURCE_ROW_NUMBER":"119798","EVENT_NO":"6254978","SURVEY_DATE":"07/20/2010","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2010-07-20"},{"SOURCE_ROW_NUMBER":"119797","EVENT_NO":"6254978","SURVEY_DATE":"07/20/2010","OCCUPATION_CD_DESC":"MECHANIC","ACT_DOSE_85":"37","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2010-07-20"},{"SOURCE_ROW_NUMBER":"119796","EVENT_NO":"6254978","SURVEY_DATE":"07/20/2010","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"063","ACT_DOSE_85":"59","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2010-07-20"},{"SOURCE_ROW_NUMBER":"119795","EVENT_NO":"6254903","SURVEY_DATE":"07/14/2009","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"20","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2009-07-14"},{"SOURCE_ROW_NUMBER":"119794","EVENT_NO":"6254903","SURVEY_DATE":"07/14/2009","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"063","ACT_DOSE_85":"45","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2009-07-14"},{"SOURCE_ROW_NUMBER":"119793","EVENT_NO":"6254290","SURVEY_DATE":"09/23/2008","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"120","ACT_DOSE_85":"87","PEL_DOSE_90":"77","SURVEY_TYPE":"I","sourceDate":"2008-09-23"},{"SOURCE_ROW_NUMBER":"119792","EVENT_NO":"6254290","SURVEY_DATE":"09/23/2008","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"063","ACT_DOSE_85":"3","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2008-09-23"},{"SOURCE_ROW_NUMBER":"119791","EVENT_NO":"4358788","SURVEY_DATE":"11/28/2007","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"063","ACT_DOSE_85":"20","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2007-11-28"},{"SOURCE_ROW_NUMBER":"119790","EVENT_NO":"4358788","SURVEY_DATE":"11/28/2007","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2007-11-28"},{"SOURCE_ROW_NUMBER":"119789","EVENT_NO":"4358788","SURVEY_DATE":"11/28/2007","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"063","ACT_DOSE_85":"15","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2007-11-28"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":3,"firstDate":"2005-04-18","lastDate":"2010-07-01","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":13.8,"validSamples":3,"quartzPctTotal":31.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"151071","CASSETTE_NO":"57851150","SAMPLE_DT":"07/01/2010","QUARTZ_PCT":"10.0","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-07-01"},{"SOURCE_ROW_NUMBER":"35476","CASSETTE_NO":"57616728","SAMPLE_DT":"01/04/2006","QUARTZ_PCT":"13.8","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-01-04"},{"SOURCE_ROW_NUMBER":"146992","CASSETTE_NO":"57507114","SAMPLE_DT":"04/18/2005","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-18"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":22,"firstDate":"2004-07-14","lastDate":"2014-09-24","metrics":{"ss":7,"amountDue":2408,"contested":0,"amountPaid":2408,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2408},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1261103","VIOLATION_NO":"8046928","VIOLATION_ISSUE_DT":"09/24/2014","SIG_SUB":"N","PART_SECTION":"77.1103(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/24/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-09-24"},{"SOURCE_ROW_NUMBER":"1261106","VIOLATION_NO":"8046586","VIOLATION_ISSUE_DT":"02/18/2014","SIG_SUB":"N","PART_SECTION":"71.403(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/18/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-02-18"},{"SOURCE_ROW_NUMBER":"1261094","VIOLATION_NO":"8036430","VIOLATION_ISSUE_DT":"01/11/2012","SIG_SUB":"N","PART_SECTION":"77.1109(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/11/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-01-11"},{"SOURCE_ROW_NUMBER":"1261104","VIOLATION_NO":"8029040","VIOLATION_ISSUE_DT":"11/08/2010","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/08/2010","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2010-11-08"},{"SOURCE_ROW_NUMBER":"1261099","VIOLATION_NO":"8028681","VIOLATION_ISSUE_DT":"07/01/2010","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/01/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-07-01"},{"SOURCE_ROW_NUMBER":"1261095","VIOLATION_NO":"8022777","VIOLATION_ISSUE_DT":"03/02/2010","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/04/2010","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2010-03-02"},{"SOURCE_ROW_NUMBER":"1261100","VIOLATION_NO":"6610000","VIOLATION_ISSUE_DT":"07/14/2009","SIG_SUB":"Y","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/14/2009","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"499","CONTESTED_IND":"N","sourceDate":"2009-07-14"},{"SOURCE_ROW_NUMBER":"1261096","VIOLATION_NO":"8015366","VIOLATION_ISSUE_DT":"03/23/2009","SIG_SUB":"N","PART_SECTION":"41.20","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/23/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-03-23"},{"SOURCE_ROW_NUMBER":"1261105","VIOLATION_NO":"6602806","VIOLATION_ISSUE_DT":"11/27/2007","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/03/2007","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2007-11-27"},{"SOURCE_ROW_NUMBER":"1261098","VIOLATION_NO":"7112128","VIOLATION_ISSUE_DT":"05/15/2007","SIG_SUB":"N","PART_SECTION":"77.1200(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/23/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2007-05-15"},{"SOURCE_ROW_NUMBER":"1261093","VIOLATION_NO":"7137317","VIOLATION_ISSUE_DT":"01/09/2007","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/10/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-01-09"},{"SOURCE_ROW_NUMBER":"1261092","VIOLATION_NO":"7137316","VIOLATION_ISSUE_DT":"01/09/2007","SIG_SUB":"Y","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/10/2007","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2007-01-09"}]}],"safety":{"href":"/api/v1/mines/1800756/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1800756/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Flammable liquids; storage.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1103","part":"77","subchapter":"O","subpart":"L","id":"77.1103","citation":"30 CFR 77.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Waiver of surface facilities requirements; posting of waiver.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-E/section-71.403","part":"71","subchapter":"O","subpart":"E","id":"71.403","citation":"30 CFR 71.403","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 41.20","heading":"Legal identity report.","id":"41.20","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-G/part-41/subpart-C/section-41.20","part":"41","partHeading":"PART 41—NOTIFICATION OF LEGAL IDENTITY","subchapter":"G","subchapterHeading":"SUBCHAPTER G—FILING AND OTHER ADMINISTRATIVE REQUIREMENTS","subpart":"C","subpartHeading":"Subpart C—Operator's Report to the Mine Safety and Health Administration","text":"Each operator of a coal or other mine shall file notification of legal identity and every change thereof with the appropriate district manager of the Mine Safety and Health Administration by properly completing, mailing, or otherwise delivering form 2000-7 “legal identity report” which shall be provided by the Mine Safety and Health Administration for this purpose. If additional space is required, the operator may use a separate sheet or sheets.","occurrenceCount":1},{"chapter":"I","heading":"Mine map.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-M/section-77.1200","part":"77","subchapter":"O","subpart":"M","id":"77.1200","citation":"30 CFR 77.1200","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1800756","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}