{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1800749","name":"Vindex Douglas","status":"Abandoned","status_date":"2014-08-20","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"MD","county":"Garrett","nearest_town":"Swanton","operator_id":"P23706","operator_name":"Vindex Energy LLC","controller_id":"C15561","controller_name":"Arch Resources Inc","district":"C03","office":"Morgantown District","employees":0,"latitude":39.495647,"longitude":-79.228063},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":3828},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1800749","name":"Vindex Douglas"},"operator":{"type":"operator","id":"P23706","name":"Vindex Energy LLC"},"controller":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12472","name":"Anker Group Inc"},"object":{"type":"mine","id":"1800749","name":"Vindex Douglas"},"validFrom":"1997-02-10","validTo":"2005-11-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800749|C12472|1997-02-10|2005-11-17"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23706","name":"Vindex Energy LLC"},"object":{"type":"mine","id":"1800749","name":"Vindex Douglas"},"validFrom":"2000-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800749|P23706|2000-09-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12472","name":"Anker Group Inc"},"object":{"type":"operator","id":"P23706","name":"Vindex Energy LLC"},"validFrom":"2000-09-01","validTo":"2005-11-17","current":false,"derived":true,"evidenceMineId":"1800749","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800749|P23706|2000-09-01|C12472|1997-02-10|87046"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0045307","name":"International Coal Group Inc (ICG)"},"object":{"type":"mine","id":"1800749","name":"Vindex Douglas"},"validFrom":"2005-11-18","validTo":"2011-06-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800749|0045307|2005-11-18|2011-06-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0045307","name":"International Coal Group Inc (ICG)"},"object":{"type":"operator","id":"P23706","name":"Vindex Energy LLC"},"validFrom":"2005-11-18","validTo":"2011-06-14","current":false,"derived":true,"evidenceMineId":"1800749","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800749|P23706|2000-09-01|0045307|2005-11-18|5354"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"mine","id":"1800749","name":"Vindex Douglas"},"validFrom":"2011-06-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800749|C15561|2011-06-15|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"operator","id":"P23706","name":"Vindex Energy LLC"},"validFrom":"2011-06-15","validTo":null,"current":true,"derived":true,"evidenceMineId":"1800749","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800749|P23706|2000-09-01|C15561|2011-06-15|96174"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":12,"firstDate":"2005-11-04","lastDate":"2011-11-04","metrics":{"daysLost":205,"injuries":12,"fatalities":0,"recentRows":0,"restrictedDays":46,"contractorRecords":4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"152207","DOCUMENT_NO":"220113120024","ACCIDENT_DT":"11/04/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was dismounting dozer after positioning the equipment for maintenance. Upon dismounting he raised the lid of the battery box to gain access for required task. In traveling down, he placed his hand on edge of battery box, the locking spring mechanism, which was supposed to hold lid open failed catching employee's hand. Resulting in a laceration to hand, needing 3 sutures.","sourceDate":"2011-11-04"},{"SOURCE_ROW_NUMBER":"264113","DOCUMENT_NO":"220112630030","ACCIDENT_DT":"09/16/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE exited the cab of the CAT992G to remove debris from the equipment.  While working to remove the debris EE lost his hard hat on the ground.  Upon returning to the cab struck his head on the side mirror lacerating his scalp.  The laceration required 4 staples to close.","sourceDate":"2011-09-16"},{"SOURCE_ROW_NUMBER":"208128","DOCUMENT_NO":"220103410003","ACCIDENT_DT":"11/29/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Drill operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee fell while getting down from grader. Foot slipped, causing fall. Tried to break fall by putting hands out, causing strain on left hand. He reported to supervisor, refused medical treatment. Went to ER next morning 11/30/10, and had hand X-Rayed. Employee came to work that day, missed no time. Hospital notified him 12/5/2010 with the results, confirmed his hand was broken.","sourceDate":"2010-11-29"},{"SOURCE_ROW_NUMBER":"44639","DOCUMENT_NO":"220093310008","ACCIDENT_DT":"11/16/2009","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Checking density on truck and saw a cap falling in hole. Bent over to get it and felt a pain in back.","sourceDate":"2009-11-16"},{"SOURCE_ROW_NUMBER":"199423","DOCUMENT_NO":"220090090017","ACCIDENT_DT":"01/05/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"After parking the Fuel/Lube Truck employee walked behind the truck where he slipped/tripped on the frozen ground resulting in a sprained ankle.","sourceDate":"2009-01-05"},{"SOURCE_ROW_NUMBER":"104616","DOCUMENT_NO":"220082970004","ACCIDENT_DT":"10/16/2008","DEGREE_INJURY":"ALL OTHER CASES (INCL 1ST AID)","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While descending a Cat 988F Loader, the miner slipped and caught himself, causing a strain to his right shoulder.","sourceDate":"2008-10-16"},{"SOURCE_ROW_NUMBER":"87714","DOCUMENT_NO":"220082520033","ACCIDENT_DT":"09/04/2008","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Blaster, Shooter, Shotfirer, Explosive worker, Powder gang/monkey","NO_INJURIES":"1","DAYS_LOST":"33","NARRATIVE":"Lifitng bags of dirt and felt burning sensation in stomach and a lump in side.","sourceDate":"2008-09-04"},{"SOURCE_ROW_NUMBER":"1727","DOCUMENT_NO":"220082390004","ACCIDENT_DT":"08/21/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using his finger to hold a keeper washer in place instead of a screw driver while putting a guard on a ripper shank. The guard slipped and cut the tip of his finger.  Employee was taken to the hospital where he received 2 stitches to close the wound. He returned to work the next scheduled shift. No lost time.","sourceDate":"2008-08-21"},{"SOURCE_ROW_NUMBER":"216798","DOCUMENT_NO":"220082350012","ACCIDENT_DT":"08/20/2008","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee went to use a port-a-pot. As he opened the door he was attacked by bees. Employee ran from the area and slipped and fell landing on his right side.","sourceDate":"2008-08-20"},{"SOURCE_ROW_NUMBER":"221069","DOCUMENT_NO":"220073600086","ACCIDENT_DT":"12/11/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee was holding hood door open while checking oil. A gust of wind blew hood out of his hand causing hood to fall hitting him in back of head & neck. He was wearing his hard hat.","sourceDate":"2007-12-11"},{"SOURCE_ROW_NUMBER":"139296","DOCUMENT_NO":"220061320030","ACCIDENT_DT":"05/04/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Water truck operator","NO_INJURIES":"1","DAYS_LOST":"165","NARRATIVE":"EE was operating a 1970 Mack water truck when the vehicle came out of gear. Operator could not get the truck back into gear. He removed his seat belt in an attempt to jump but decided to ride it out, to prevent any injury to fellow workers in the area. As he made a sharp right turn, the vehicle overturned 2 times, ejecting him from the vehicle. An investigation is ongoing.","sourceDate":"2006-05-04"},{"SOURCE_ROW_NUMBER":"23199","DOCUMENT_NO":"220053110028","ACCIDENT_DT":"11/04/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Mechanic was hammering on a drill bit on a Drill Tech DK45 highwall drill with a sledge hammer when a metal fragment  struck the mechanic and lodged in the left side of his jaw.  Employee went to the hospital and the object was removed.  Employee reported to work the next day.","sourceDate":"2005-11-04"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-08-20","lastDate":"2014-08-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":102,"firstDate":"2001-06-13","lastDate":"2014-06-25","metrics":{"ss":49,"delinquent":94,"recentRows":0,"paidPenalty":32391,"proposedPenalty":38267,"currentAssessment":37741},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1722890","VIOLATION_NO":"8046524","ISSUE_DT":"06/25/2014","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-06-25"},{"SOURCE_ROW_NUMBER":"1722779","VIOLATION_NO":"8046353","ISSUE_DT":"12/23/2013","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"1702569","VIOLATION_NO":"8046319","ISSUE_DT":"08/13/2013","CFR_STANDARD_CD":"62.130(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1702568","VIOLATION_NO":"8046318","ISSUE_DT":"08/13/2013","CFR_STANDARD_CD":"50.40(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1701887","VIOLATION_NO":"7114437","ISSUE_DT":"10/11/2012","CFR_STANDARD_CD":"47.41(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-11"},{"SOURCE_ROW_NUMBER":"1701786","VIOLATION_NO":"7114279","ISSUE_DT":"07/23/2012","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"1701536","VIOLATION_NO":"8036417","ISSUE_DT":"01/05/2012","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"260.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-05"},{"SOURCE_ROW_NUMBER":"1701535","VIOLATION_NO":"8036416","ISSUE_DT":"01/04/2012","CFR_STANDARD_CD":"77.1109(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"1701534","VIOLATION_NO":"8036415","ISSUE_DT":"01/04/2012","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"1678952","VIOLATION_NO":"8036294","ISSUE_DT":"09/23/2011","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"540.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"1678951","VIOLATION_NO":"8036293","ISSUE_DT":"09/23/2011","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"1678950","VIOLATION_NO":"8036292","ISSUE_DT":"09/23/2011","CFR_STANDARD_CD":"77.410(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-23"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":7,"firstDate":"2010-02-26","lastDate":"2013-02-06","metrics":{"appeals":0,"decisions":7,"recentRows":0,"decisionPenalty":3630,"originalPenalty":4156},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"319645","VIOLATION_NO":"8036417","DOCKET_NO":"YORK 2012-110","DECISION_DT":"02/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"260.00","JUDGE_FIRST_NAME":"George","JUDGE_LAST_NAME":"Koutras","sourceDate":"2013-02-06"},{"SOURCE_ROW_NUMBER":"319614","VIOLATION_NO":"8036415","DOCKET_NO":"YORK 2012-110","DECISION_DT":"02/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"George","JUDGE_LAST_NAME":"Koutras","sourceDate":"2013-02-06"},{"SOURCE_ROW_NUMBER":"260168","VIOLATION_NO":"8015713","DOCKET_NO":"YORK 2010-51","DECISION_DT":"03/02/2011","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-03-02"},{"SOURCE_ROW_NUMBER":"46554","VIOLATION_NO":"8015652","DOCKET_NO":"YORK 2010-1","DECISION_DT":"09/03/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-09-03"},{"SOURCE_ROW_NUMBER":"46553","VIOLATION_NO":"8015647","DOCKET_NO":"YORK 2010-1","DECISION_DT":"09/03/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2010-09-03"},{"SOURCE_ROW_NUMBER":"33372","VIOLATION_NO":"6611774","DOCKET_NO":"YORK 2009-78","DECISION_DT":"03/08/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"108.00","DECISION_PENALTY_AMT":"108.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2010-03-08"},{"SOURCE_ROW_NUMBER":"236894","VIOLATION_NO":"6611771","DOCKET_NO":"YORK 2009-77","DECISION_DT":"02/26/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2010-02-26"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":139,"firstDate":"2001-01-10","lastDate":"2014-04-29","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":3,"validSamples":136,"maxConcentration":2.379,"concentrationTotal":26.851},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1573991","CASS_NUM":"58107182","SMP_TAKEN_DT":"4/29/2014","CONC":".023","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-29"},{"SOURCE_ROW_NUMBER":"1521296","CASS_NUM":"58107169","SMP_TAKEN_DT":"4/29/2014","CONC":".044","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-04-29"},{"SOURCE_ROW_NUMBER":"1350997","CASS_NUM":"58107353","SMP_TAKEN_DT":"12/23/2013","CONC":".011","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"303432","CASS_NUM":"58107140","SMP_TAKEN_DT":"12/23/2013","CONC":".083","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"1126273","CASS_NUM":"58106832","SMP_TAKEN_DT":"8/13/2013","CONC":".071","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"798868","CASS_NUM":"58106860","SMP_TAKEN_DT":"8/13/2013","CONC":".057","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1030185","CASS_NUM":"57985251","SMP_TAKEN_DT":"10/10/2012","CONC":".033","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"422776","CASS_NUM":"57985624","SMP_TAKEN_DT":"10/10/2012","CONC":".112","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"1206602","CASS_NUM":"57985431","SMP_TAKEN_DT":"7/23/2012","CONC":".034","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"895961","CASS_NUM":"57985425","SMP_TAKEN_DT":"7/23/2012","CONC":".087","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"895158","CASS_NUM":"57985465","SMP_TAKEN_DT":"7/23/2012","CONC":".054","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"393420","CASS_NUM":"57985374","SMP_TAKEN_DT":"7/23/2012","CONC":".106","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MINE FOREMAN/MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-23"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":3,"firstDate":"2006-11-09","lastDate":"2008-06-18","metrics":{"linkedIssuances":3},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":7,"firstDate":"2008-11-05","lastDate":"2012-01-05","metrics":{"decisions":7,"ssChanged":2,"recentRows":0,"decisionPenalty":3630,"proposedPenalty":4156},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"310093","CITATION_NO":"8036417","CITATION_ISSUE_DT":"01/05/2012","DOCKET_NO":"YORK 2012-110","DECISION_DT":"02/06/2013","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"260.00","sourceDate":"2012-01-05"},{"SOURCE_ROW_NUMBER":"202191","CITATION_NO":"8036415","CITATION_ISSUE_DT":"01/04/2012","DOCKET_NO":"YORK 2012-110","DECISION_DT":"02/06/2013","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"127749","CITATION_NO":"8015713","CITATION_ISSUE_DT":"08/31/2009","DOCKET_NO":"YORK 2010-51","DECISION_DT":"03/02/2011","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2009-08-31"},{"SOURCE_ROW_NUMBER":"70816","CITATION_NO":"8015652","CITATION_ISSUE_DT":"08/11/2009","DOCKET_NO":"YORK 2010-1","DECISION_DT":"09/03/2010","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2009-08-11"},{"SOURCE_ROW_NUMBER":"296751","CITATION_NO":"8015647","CITATION_ISSUE_DT":"08/05/2009","DOCKET_NO":"YORK 2010-1","DECISION_DT":"09/03/2010","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2009-08-05"},{"SOURCE_ROW_NUMBER":"180886","CITATION_NO":"6611774","CITATION_ISSUE_DT":"11/05/2008","DOCKET_NO":"YORK 2009-78","DECISION_DT":"03/08/2010","CFR_STANDARD_CODE":"77.1000","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"108.00","DECISION_PENALTY_AMT":"108.00","sourceDate":"2008-11-05"},{"SOURCE_ROW_NUMBER":"122101","CITATION_NO":"6611771","CITATION_ISSUE_DT":"11/05/2008","DOCKET_NO":"YORK 2009-77","DECISION_DT":"02/26/2010","CFR_STANDARD_CODE":"77.207","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2008-11-05"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":2654,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":15,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":550,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":15,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2000-09-01","lastDate":"2000-09-01","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":48,"firstDate":"2001-01-09","lastDate":"2014-08-20","metrics":{"inspectors":61,"recentRows":0,"onSiteHours":972.25,"inspectionHours":1554,"inspectionSamples":194},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"858609","EVENT_NO":"6265468","INSPECTION_BEGIN_DT":"08/20/2014","INSPECTION_END_DT":"08/20/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2014-08-20"},{"SOURCE_ROW_NUMBER":"179753","EVENT_NO":"6265524","INSPECTION_BEGIN_DT":"06/25/2014","INSPECTION_END_DT":"06/25/2014","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2014-06-25"},{"SOURCE_ROW_NUMBER":"175647","EVENT_NO":"6265490","INSPECTION_BEGIN_DT":"04/24/2014","INSPECTION_END_DT":"04/30/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20.5","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2014-04-24"},{"SOURCE_ROW_NUMBER":"567219","EVENT_NO":"6265484","INSPECTION_BEGIN_DT":"12/03/2013","INSPECTION_END_DT":"12/27/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2013-12-03"},{"SOURCE_ROW_NUMBER":"1107317","EVENT_NO":"6259563","INSPECTION_BEGIN_DT":"07/01/2013","INSPECTION_END_DT":"09/13/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"20","sourceDate":"2013-07-01"},{"SOURCE_ROW_NUMBER":"63953","EVENT_NO":"6259434","INSPECTION_BEGIN_DT":"10/01/2012","INSPECTION_END_DT":"11/26/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"16.5","sourceDate":"2012-10-01"},{"SOURCE_ROW_NUMBER":"334745","EVENT_NO":"6259429","INSPECTION_BEGIN_DT":"05/10/2012","INSPECTION_END_DT":"07/24/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"33.5","SUM_TOTAL_ON_SITE_HOURS":"19","sourceDate":"2012-05-10"},{"SOURCE_ROW_NUMBER":"785573","EVENT_NO":"6259410","INSPECTION_BEGIN_DT":"01/04/2012","INSPECTION_END_DT":"03/05/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"43","SUM_TOTAL_ON_SITE_HOURS":"26","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"746760","EVENT_NO":"6259452","INSPECTION_BEGIN_DT":"11/22/2011","INSPECTION_END_DT":"11/22/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2011-11-22"},{"SOURCE_ROW_NUMBER":"365962","EVENT_NO":"6254998","INSPECTION_BEGIN_DT":"09/16/2011","INSPECTION_END_DT":"09/28/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"65","SUM_TOTAL_ON_SITE_HOURS":"40.5","sourceDate":"2011-09-16"},{"SOURCE_ROW_NUMBER":"821736","EVENT_NO":"6259260","INSPECTION_BEGIN_DT":"11/22/2010","INSPECTION_END_DT":"01/06/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"87","SUM_TOTAL_ON_SITE_HOURS":"63.5","sourceDate":"2010-11-22"},{"SOURCE_ROW_NUMBER":"57506","EVENT_NO":"6254828","INSPECTION_BEGIN_DT":"09/15/2010","INSPECTION_END_DT":"09/15/2010","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2010-09-15"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":86,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014-Q3":{"hours":427,"employees":2,"production":0},"2014-Q2":{"hours":2993,"employees":5,"production":0},"2014-Q1":{"hours":2398,"employees":3,"production":0},"2013-Q4":{"hours":2441,"employees":4,"production":0},"2013-Q3":{"hours":3074,"employees":4,"production":0},"2013-Q2":{"hours":4263,"employees":4,"production":0},"2013-Q1":{"hours":3279,"employees":6,"production":0},"2012-Q4":{"hours":1226,"employees":4,"production":0},"2012-Q3":{"hours":1700,"employees":3,"production":0},"2012-Q2":{"hours":1827,"employees":2,"production":0},"2012-Q1":{"hours":4119,"employees":8,"production":693},"2011-Q4":{"hours":12394,"employees":18,"production":42382}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":133453,"employees":55,"production":606346},"2006":{"hours":142509,"employees":59,"production":621198},"2007":{"hours":69871,"employees":28,"production":295179},"2008":{"hours":81117,"employees":29,"production":350492},"2009":{"hours":77809,"employees":38,"production":220406},"2010":{"hours":81942,"employees":33,"production":262067},"2011":{"hours":79666,"employees":29,"production":237822},"2012":{"hours":8872,"employees":4,"production":693},"2013":{"hours":13057,"employees":5,"production":0},"2014":{"hours":5818,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":64,"firstDate":"2004-12-13","lastDate":"2014-04-29","metrics":{"recentRows":0,"doseOver100":7,"actDoseTotal":3846,"pelDoseTotal":2144},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"119678","EVENT_NO":"6265490","SURVEY_DATE":"04/29/2014","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"44","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2014-04-29"},{"SOURCE_ROW_NUMBER":"119677","EVENT_NO":"6265490","SURVEY_DATE":"04/29/2014","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"063","ACT_DOSE_85":"110","PEL_DOSE_90":"101","SURVEY_TYPE":"I","sourceDate":"2014-04-29"},{"SOURCE_ROW_NUMBER":"119674","EVENT_NO":"6259563","SURVEY_DATE":"08/15/2013","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"51","PEL_DOSE_90":"11","SURVEY_TYPE":"F","sourceDate":"2013-08-15"},{"SOURCE_ROW_NUMBER":"119676","EVENT_NO":"6259563","SURVEY_DATE":"08/13/2013","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"51","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"119675","EVENT_NO":"6259563","SURVEY_DATE":"08/13/2013","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"258","PEL_DOSE_90":"226","SURVEY_TYPE":"I","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"119673","EVENT_NO":"6259434","SURVEY_DATE":"10/10/2012","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"40","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"119672","EVENT_NO":"6259434","SURVEY_DATE":"10/10/2012","OCCUPATION_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","MACHINE_CD":"39","MANUFACTURER_CD":"020","ACT_DOSE_85":"11","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"119660","EVENT_NO":"6254998","SURVEY_DATE":"09/23/2011","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"11","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"119659","EVENT_NO":"6254998","SURVEY_DATE":"09/23/2011","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"62","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"119658","EVENT_NO":"6254998","SURVEY_DATE":"09/23/2011","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"38","MANUFACTURER_CD":"018","ACT_DOSE_85":"20","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"119657","EVENT_NO":"6254998","SURVEY_DATE":"09/23/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"16","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"119656","EVENT_NO":"6254998","SURVEY_DATE":"09/23/2011","OCCUPATION_CD_DESC":"MECHANIC HELPER","MACHINE_CD":"39","MANUFACTURER_CD":"055","ACT_DOSE_85":"21","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2011-09-23"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":27,"firstDate":"2001-01-10","lastDate":"2011-02-09","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":43.3,"validSamples":25,"quartzPctTotal":472.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"9673","CASSETTE_NO":"51086763","SAMPLE_DT":"02/09/2011","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2011-02-09"},{"SOURCE_ROW_NUMBER":"89574","CASSETTE_NO":"51086779","SAMPLE_DT":"02/04/2011","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"BACKHOE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2011-02-04"},{"SOURCE_ROW_NUMBER":"125591","CASSETTE_NO":"57876779","SAMPLE_DT":"01/04/2011","QUARTZ_PCT":"19.2","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-04"},{"SOURCE_ROW_NUMBER":"96148","CASSETTE_NO":"57876776","SAMPLE_DT":"01/04/2011","QUARTZ_PCT":"18.6","OCC_CODE_DESC":"BACKHOE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-04"},{"SOURCE_ROW_NUMBER":"53361","CASSETTE_NO":"51043955","SAMPLE_DT":"04/01/2010","QUARTZ_PCT":"10.7","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-04-01"},{"SOURCE_ROW_NUMBER":"153305","CASSETTE_NO":"51043917","SAMPLE_DT":"03/16/2010","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-03-16"},{"SOURCE_ROW_NUMBER":"164565","CASSETTE_NO":"57820804","SAMPLE_DT":"02/22/2010","QUARTZ_PCT":"36.3","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-22"},{"SOURCE_ROW_NUMBER":"109967","CASSETTE_NO":"57820799","SAMPLE_DT":"02/22/2010","QUARTZ_PCT":"18.3","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-02-22"},{"SOURCE_ROW_NUMBER":"76546","CASSETTE_NO":"57710903","SAMPLE_DT":"03/19/2008","QUARTZ_PCT":"23.4","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-19"},{"SOURCE_ROW_NUMBER":"75546","CASSETTE_NO":"57710912","SAMPLE_DT":"03/19/2008","QUARTZ_PCT":"25.8","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-19"},{"SOURCE_ROW_NUMBER":"121958","CASSETTE_NO":"57638904","SAMPLE_DT":"02/12/2007","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-02-12"},{"SOURCE_ROW_NUMBER":"135340","CASSETTE_NO":"57638838","SAMPLE_DT":"01/24/2007","QUARTZ_PCT":"21.0","OCC_CODE_DESC":"HIGHWALL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-01-24"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":108,"firstDate":"2001-06-13","lastDate":"2014-06-25","metrics":{"ss":52,"amountDue":37741,"contested":5,"amountPaid":32391,"recentRows":0,"section104d":3,"unterminated":2,"proposedPenalty":38267},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1260385","VIOLATION_NO":"8046524","VIOLATION_ISSUE_DT":"06/25/2014","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/25/2014","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2014-06-25"},{"SOURCE_ROW_NUMBER":"1260428","VIOLATION_NO":"8046353","VIOLATION_ISSUE_DT":"12/23/2013","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/23/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"1260387","VIOLATION_NO":"8046319","VIOLATION_ISSUE_DT":"08/13/2013","SIG_SUB":"N","PART_SECTION":"62.130(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/15/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1260386","VIOLATION_NO":"8046318","VIOLATION_ISSUE_DT":"08/13/2013","SIG_SUB":"N","PART_SECTION":"50.40(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/13/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-13"},{"SOURCE_ROW_NUMBER":"1260408","VIOLATION_NO":"7114437","VIOLATION_ISSUE_DT":"10/11/2012","SIG_SUB":"N","PART_SECTION":"47.41(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/11/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-11"},{"SOURCE_ROW_NUMBER":"1260365","VIOLATION_NO":"7114279","VIOLATION_ISSUE_DT":"07/23/2012","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-23"},{"SOURCE_ROW_NUMBER":"1260323","VIOLATION_NO":"8036417","VIOLATION_ISSUE_DT":"01/05/2012","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/05/2012","PROPOSED_PENALTY":"362","AMOUNT_DUE":"260","AMOUNT_PAID":"260","CONTESTED_IND":"N","sourceDate":"2012-01-05"},{"SOURCE_ROW_NUMBER":"1260322","VIOLATION_NO":"8036416","VIOLATION_ISSUE_DT":"01/04/2012","SIG_SUB":"N","PART_SECTION":"77.1109(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/04/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"1260321","VIOLATION_NO":"8036415","VIOLATION_ISSUE_DT":"01/04/2012","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/05/2012","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"N","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"1260407","VIOLATION_NO":"8036294","VIOLATION_ISSUE_DT":"09/23/2011","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2011","PROPOSED_PENALTY":"540","AMOUNT_DUE":"540","AMOUNT_PAID":"540","CONTESTED_IND":"N","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"1260406","VIOLATION_NO":"8036293","VIOLATION_ISSUE_DT":"09/23/2011","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2011","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2011-09-23"},{"SOURCE_ROW_NUMBER":"1260405","VIOLATION_NO":"8036292","VIOLATION_ISSUE_DT":"09/23/2011","SIG_SUB":"N","PART_SECTION":"77.410(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/23/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-09-23"}]}],"safety":{"href":"/api/v1/mines/1800749/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1800749/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 62.130","heading":"Permissible exposure level.","id":"62.130","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-M/part-62/section-62.130","part":"62","partHeading":"PART 62—OCCUPATIONAL NOISE EXPOSURE","subchapter":"M","subchapterHeading":"SUBCHAPTER M—UNIFORM MINE HEALTH REGULATIONS","subpart":"","subpartHeading":"","text":"(a) The mine operator must assure that no miner is exposed during any work shift to noise that exceeds the permissible exposure level. If during any work shift a miner's noise exposure exceeds the permissible exposure level, the mine operator must use all feasible engineering and administrative controls to reduce the miner's noise exposure to the permissible exposure level, and enroll the miner in a hearing conservation program that complies with § 62.150 of this part. When a mine operator uses administrative controls to reduce a miner's exposure, the mine operator must post the procedures for such controls on the mine bulletin board and provide a copy to the affected miner.\n\n(b) If a miner's noise exposure continues to exceed the permissible exposure level despite the use of all feasible engineering and administrative controls, the mine operator must continue to use the engineering and administrative controls to reduce the miner's noise exposure to as low a level as is feasible.\n\n(c) The mine operator must assure that no miner is exposed at any time to sound levels exceeding 115 dBA, as determined without adjustment for the use of any hearing protector.","occurrenceCount":1},{"chapter":"I","heading":"Maintenance of records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-I/part-50/subpart-E/section-50.40","part":"50","subchapter":"I","subpart":"E","id":"50.40","citation":"30 CFR 50.40","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER I—ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND PRODUCTION IN MINES","partHeading":"PART 50—NOTIFICATION, INVESTIGATION, REPORTS AND RECORDS OF ACCIDENTS, INJURIES, ILLNESSES, EMPLOYMENT, AND COAL PRODUCTION IN MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 47.41","heading":"Requirement for container labels.","id":"47.41","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-47/subpart-E/section-47.41","part":"47","partHeading":"PART 47—HAZARD COMMUNICATION (HazCom)","subchapter":"H","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","subpart":"E","subpartHeading":"Subpart E—Container Labels and Other Forms of Warning","text":"(a) The operator must ensure that each container of a hazardous chemical has a label. If a container is tagged or marked with the appropriate information, it is labeled.\n\n(1) The operator must replace a container label immediately if it is missing or if the hazard information on the label is unreadable.\n\n(2) The operator must not remove or deface existing labels on containers of hazardous chemicals.\n\n(b) For each hazardous chemical produced at the mine, the operator must prepare a container label and update this label with any significant, new information about the chemical's hazards within 3 months of becoming aware of this information.\n\n(c) For each hazardous chemical brought to the mine, the operator must replace an outdated label when a revised label is received from the chemical's manufacturer or supplier. The operator is not responsible for an inaccurate label obtained from the chemical's manufacturer or supplier.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1800749","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}