{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1800621","name":"Mettiki Mine","status":"Abandoned and Sealed","status_date":"2012-01-18","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"MD","county":"Garrett","nearest_town":"Oakland","operator_id":"P23517","operator_name":"Mettiki Coal LLC","controller_id":"C15455","controller_name":"Alliance Resource Partners LP","district":"C03","office":"Morgantown District","employees":0,"latitude":39.258055,"longitude":-79.454722},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":5550},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1800621","name":"Mettiki Mine"},"operator":{"type":"operator","id":"P23517","name":"Mettiki Coal LLC"},"controller":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"P03535","name":"Mettiki Coal Corp"},"object":{"type":"mine","id":"1800621","name":"Mettiki Mine"},"validFrom":"1976-06-18","validTo":"1996-09-09","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800621|P03535|1976-06-18|1996-09-09"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01148","name":"MAPCO Inc"},"object":{"type":"mine","id":"1800621","name":"Mettiki Mine"},"validFrom":"1976-06-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800621|C01148|1976-06-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01148","name":"MAPCO Inc"},"object":{"type":"operator","id":"P03535","name":"Mettiki Coal Corp"},"validFrom":"1976-06-18","validTo":"1996-09-09","current":false,"derived":true,"evidenceMineId":"1800621","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800621|P03535|1976-06-18|C01148|1976-06-18|52570"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23517","name":"Mettiki Coal LLC"},"object":{"type":"mine","id":"1800621","name":"Mettiki Mine"},"validFrom":"1996-09-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800621|P23517|1996-09-10|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"1800621","name":"Mettiki Mine"},"validFrom":"1996-09-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800621|C15455|1996-09-10|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"P23517","name":"Mettiki Coal LLC"},"validFrom":"1996-09-10","validTo":null,"current":true,"derived":true,"evidenceMineId":"1800621","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1800621|P23517|1996-09-10|C15455|1996-09-10|95633"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":226,"firstDate":"2000-01-09","lastDate":"2009-06-09","metrics":{"daysLost":4236,"injuries":198,"fatalities":1,"recentRows":0,"restrictedDays":145,"contractorRecords":47},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"225303","DOCUMENT_NO":"220091660060","ACCIDENT_DT":"06/09/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE had a flat tire. EE took spare tire off truck. Spare tire bounced to ground and came in contact with EE's left pinkie finger. Left pinkie finger was bruised. EE's carelessness was the result of this injury. EE was instructed to be more careful and to wait on someone else to fix flat tires, as this is not a part of her job dities.","sourceDate":"2009-06-09"},{"SOURCE_ROW_NUMBER":"83429","DOCUMENT_NO":"220062830107","ACCIDENT_DT":"10/02/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Person was using a cutting torch to remove bolts in air-lock door. Person was using left hand to hold cables up out of the way and cutting bolts with right hand. He slipped and lost balance and the torch in right hand came in contact with left hand causing burn to palm & thumb.","sourceDate":"2006-10-02"},{"SOURCE_ROW_NUMBER":"36116","DOCUMENT_NO":"220062650041","ACCIDENT_DT":"09/14/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Person was walking down main belts on fireboss exam. At #2-#3 bk on #1 belt he slipped and tried to catch himself. His left hand caught top belt roller structure and his ring finger on left hand caught between roller and frame causing injury to ring finger.","sourceDate":"2006-09-14"},{"SOURCE_ROW_NUMBER":"36115","DOCUMENT_NO":"220061950045","ACCIDENT_DT":"07/04/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured person was helping to change out ram jack on longwall support #30. Person was using come-along to pull jack upward to remove pin, when the jack came loose and struck person in forehead causing laceration. Required 6 sutures to close the laceration.","sourceDate":"2006-07-04"},{"SOURCE_ROW_NUMBER":"74720","DOCUMENT_NO":"220061840076","ACCIDENT_DT":"06/27/2006","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A fall of roof occurred at the #6 BK intersection off the E-1 track entery just outby #15 seal. Fall was in the intersection and was approx. 16' X 16' X 6' high. Area was cleaned up and supported.","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"70379","DOCUMENT_NO":"220061250036","ACCIDENT_DT":"04/28/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Person was unloading post from back of hummer on the longwall section. The post end came down and caught his ring finger between post and monorail dolly which was laying on the ground. The distal end of right ring finger was fractured.","sourceDate":"2006-04-28"},{"SOURCE_ROW_NUMBER":"152200","DOCUMENT_NO":"220061170043","ACCIDENT_DT":"04/23/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured person was helping to load 20\" ventilation tubing into scoop bucket. Person got his left hand caught between end of tubing and side of scoop bucket, causing injury to left little finger.","sourceDate":"2006-04-23"},{"SOURCE_ROW_NUMBER":"14614","DOCUMENT_NO":"220062750089","ACCIDENT_DT":"04/10/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Person was carrying bag of rock dust on shoulder to use for dusting on beltline. When he walked past starter box he stepped on rubber mat and slipped and fell causing injury to left knee. Person now has to have surgery on knee, first day off is 9/21/06.","sourceDate":"2006-04-10"},{"SOURCE_ROW_NUMBER":"195078","DOCUMENT_NO":"220060540042","ACCIDENT_DT":"02/17/2006","DEGREE_INJURY":"FATALITY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The Jeffrey Locomotive EE was operating struck a longwall support that was loaded on a low boy parked at 66 brk switch on E-1 track. Locomotives were being staged at this location for transport to Submains. Locomotives were advancing one at a time.","sourceDate":"2006-02-17"},{"SOURCE_ROW_NUMBER":"91863","DOCUMENT_NO":"220060550044","ACCIDENT_DT":"02/09/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Person was operating forklift in warehouse, he had stopped and was getting off. When he stepped down on to the floor he felt a sharp pain in the lower left side of his back. Accident was not reported until feb 14, 2006. Person was treated by a chiropractor.","sourceDate":"2006-02-09"},{"SOURCE_ROW_NUMBER":"36114","DOCUMENT_NO":"220060520047","ACCIDENT_DT":"02/09/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Loader head operator, Roscoe operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Person was setting additional support for roof. Person had a crib block on top of water prop and was raising prop towards roof. When crib block was being pressuried against the roof it kicked out and fell striking person on right hand causing injury to ring and middle fingers.","sourceDate":"2006-02-09"},{"SOURCE_ROW_NUMBER":"121927","DOCUMENT_NO":"220060380037","ACCIDENT_DT":"01/27/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Person was using utility jack to lower section of belt take-up structure into place. The structure shifted and the jack kicked out. When this happened, the jack handle struck person on right side of face. Sutures required on inside of right cheek.","sourceDate":"2006-01-27"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-01-18","lastDate":"2012-01-18","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":652,"firstDate":"2000-01-12","lastDate":"2011-12-13","metrics":{"ss":188,"delinquent":609,"recentRows":0,"paidPenalty":90980,"proposedPenalty":95980,"currentAssessment":90980},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1700904","VIOLATION_NO":"8036332","ISSUE_DT":"12/13/2011","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"720258","VIOLATION_NO":"7112156","ISSUE_DT":"03/22/2007","CFR_STANDARD_CD":"77.900-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-22"},{"SOURCE_ROW_NUMBER":"720257","VIOLATION_NO":"7112155","ISSUE_DT":"03/22/2007","CFR_STANDARD_CD":"75.1711-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-22"},{"SOURCE_ROW_NUMBER":"720058","VIOLATION_NO":"7110633","ISSUE_DT":"09/23/2006","CFR_STANDARD_CD":"75.1403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"350.00","CURRENT_ASSESSMENT_AMT":"350.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-23"},{"SOURCE_ROW_NUMBER":"720057","VIOLATION_NO":"7110468","ISSUE_DT":"09/23/2006","CFR_STANDARD_CD":"75.1911(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-23"},{"SOURCE_ROW_NUMBER":"720056","VIOLATION_NO":"7110467","ISSUE_DT":"09/23/2006","CFR_STANDARD_CD":"75.1106-5(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-23"},{"SOURCE_ROW_NUMBER":"720065","VIOLATION_NO":"7112024","ISSUE_DT":"08/07/2006","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-08-07"},{"SOURCE_ROW_NUMBER":"720064","VIOLATION_NO":"7112023","ISSUE_DT":"08/07/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"324.00","CURRENT_ASSESSMENT_AMT":"324.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-08-07"},{"SOURCE_ROW_NUMBER":"720063","VIOLATION_NO":"7112020","ISSUE_DT":"07/26/2006","CFR_STANDARD_CD":"75.1911(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-07-26"},{"SOURCE_ROW_NUMBER":"720062","VIOLATION_NO":"7112019","ISSUE_DT":"07/26/2006","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-07-26"},{"SOURCE_ROW_NUMBER":"720061","VIOLATION_NO":"7112015","ISSUE_DT":"07/20/2006","CFR_STANDARD_CD":"75.1106-5(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"720060","VIOLATION_NO":"7112014","ISSUE_DT":"07/20/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"228.00","CURRENT_ASSESSMENT_AMT":"228.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-07-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":6,"firstDate":"2002-12-02","lastDate":"2004-07-28","metrics":{"appeals":0,"decisions":6,"recentRows":0,"decisionPenalty":4555,"originalPenalty":10792},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"472702","VIOLATION_NO":"7144270","DOCKET_NO":"YORK20020005","DECISION_DT":"07/28/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"340.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"175136","VIOLATION_NO":"7143682","DOCKET_NO":"YORK20010044","DECISION_DT":"07/28/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"557.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"473213","VIOLATION_NO":"7145207","DOCKET_NO":"YORK20030017","DECISION_DT":"04/16/2004","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"340.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2004-04-16"},{"SOURCE_ROW_NUMBER":"474114","VIOLATION_NO":"7145277","DOCKET_NO":"YORK 2003-74","DECISION_DT":"08/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4000.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-08-22"},{"SOURCE_ROW_NUMBER":"473212","VIOLATION_NO":"7145203","DOCKET_NO":"YORK20030008","DECISION_DT":"08/22/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"55.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2003-08-22"},{"SOURCE_ROW_NUMBER":"473564","VIOLATION_NO":"7144848","DOCKET_NO":"YORK20020066","DECISION_DT":"12/02/2002","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5500.00","DECISION_PENALTY_AMT":"1500.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2002-12-02"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1795,"firstDate":"2000-01-03","lastDate":"2011-12-13","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":213,"validSamples":1582,"maxConcentration":58.144,"concentrationTotal":1613.936},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"146574","CASS_NUM":"57960980","SMP_TAKEN_DT":"12/13/2011","CONC":".05","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"828137","CASS_NUM":"50819636","SMP_TAKEN_DT":"9/29/2006","CONC":"1.295","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-29"},{"SOURCE_ROW_NUMBER":"516170","CASS_NUM":"50819633","SMP_TAKEN_DT":"9/29/2006","CONC":"1.604","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-29"},{"SOURCE_ROW_NUMBER":"1327868","CASS_NUM":"50819630","SMP_TAKEN_DT":"9/28/2006","CONC":"1.766","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"566615","CASS_NUM":"50819631","SMP_TAKEN_DT":"9/28/2006","CONC":"1.641","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"160254","CASS_NUM":"50819629","SMP_TAKEN_DT":"9/28/2006","CONC":".552","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-28"},{"SOURCE_ROW_NUMBER":"1570527","CASS_NUM":"57669458","SMP_TAKEN_DT":"9/20/2006","CONC":".764","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HEADGATE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"1374202","CASS_NUM":"57669651","SMP_TAKEN_DT":"9/20/2006","CONC":"1.052","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL(RETURN-SIDE FIXED)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"1176136","CASS_NUM":"57669540","SMP_TAKEN_DT":"9/20/2006","CONC":".304","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"599802","CASS_NUM":"57669465","SMP_TAKEN_DT":"9/20/2006","CONC":"1.01","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"22611","CASS_NUM":"57669495","SMP_TAKEN_DT":"9/20/2006","CONC":".079","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"3459","CASS_NUM":"57669530","SMP_TAKEN_DT":"9/20/2006","CONC":".784","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"JACK SETTER (LONGWALL)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-09-20"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":24,"firstDate":"2000-02-17","lastDate":"2005-10-14","metrics":{"linkedIssuances":24},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":1308,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":251,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"1976-06-18","lastDate":"1996-09-10","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":202,"firstDate":"2000-01-03","lastDate":"2011-12-08","metrics":{"inspectors":317,"recentRows":0,"onSiteHours":6553.5,"inspectionHours":10821,"inspectionSamples":70},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"999887","EVENT_NO":"6259315","INSPECTION_BEGIN_DT":"12/08/2011","INSPECTION_END_DT":"12/22/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2011-12-08"},{"SOURCE_ROW_NUMBER":"662440","EVENT_NO":"6259311","INSPECTION_BEGIN_DT":"09/30/2011","INSPECTION_END_DT":"09/30/2011","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2011-09-30"},{"SOURCE_ROW_NUMBER":"306095","EVENT_NO":"6259305","INSPECTION_BEGIN_DT":"06/15/2011","INSPECTION_END_DT":"06/15/2011","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"1160144","EVENT_NO":"6259351","INSPECTION_BEGIN_DT":"03/11/2011","INSPECTION_END_DT":"03/11/2011","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2011-03-11"},{"SOURCE_ROW_NUMBER":"885042","EVENT_NO":"6255039","INSPECTION_BEGIN_DT":"12/29/2010","INSPECTION_END_DT":"12/29/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2010-12-29"},{"SOURCE_ROW_NUMBER":"694430","EVENT_NO":"6255036","INSPECTION_BEGIN_DT":"09/30/2010","INSPECTION_END_DT":"09/30/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2010-09-30"},{"SOURCE_ROW_NUMBER":"1122532","EVENT_NO":"6259209","INSPECTION_BEGIN_DT":"06/29/2010","INSPECTION_END_DT":"06/29/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2010-06-29"},{"SOURCE_ROW_NUMBER":"828873","EVENT_NO":"6255024","INSPECTION_BEGIN_DT":"03/04/2010","INSPECTION_END_DT":"03/04/2010","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2010-03-04"},{"SOURCE_ROW_NUMBER":"134100","EVENT_NO":"6254970","INSPECTION_BEGIN_DT":"12/16/2009","INSPECTION_END_DT":"12/16/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2009-12-16"},{"SOURCE_ROW_NUMBER":"1009511","EVENT_NO":"6254207","INSPECTION_BEGIN_DT":"09/24/2009","INSPECTION_END_DT":"09/24/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2009-09-24"},{"SOURCE_ROW_NUMBER":"1005102","EVENT_NO":"6254219","INSPECTION_BEGIN_DT":"07/09/2009","INSPECTION_END_DT":"07/09/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2009-07-09"},{"SOURCE_ROW_NUMBER":"1087929","EVENT_NO":"6254274","INSPECTION_BEGIN_DT":"03/23/2009","INSPECTION_END_DT":"03/23/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2009-03-23"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":121,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010-Q2":{"hours":0,"employees":0,"production":0},"2007-Q4":{"hours":0,"employees":0,"production":0},"2007-Q3":{"hours":0,"employees":0,"production":0},"2007-Q2":{"hours":0,"employees":0,"production":0},"2007-Q1":{"hours":0,"employees":0,"production":0},"2006-Q4":{"hours":20916,"employees":36,"production":146872},"2006-Q3":{"hours":43782,"employees":78,"production":836819},"2006-Q2":{"hours":74230,"employees":130,"production":598683},"2006-Q1":{"hours":78042,"employees":132,"production":733167},"2005-Q4":{"hours":67470,"employees":137,"production":586839},"2005-Q3":{"hours":86080,"employees":162,"production":553520},"2005-Q2":{"hours":116065,"employees":195,"production":800675}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":459500,"employees":203,"production":2666860},"2001":{"hours":454294,"employees":201,"production":2683562},"2002":{"hours":427932,"employees":197,"production":2948427},"2003":{"hours":400710,"employees":189,"production":3251879},"2004":{"hours":417282,"employees":186,"production":3145853},"2005":{"hours":384980,"employees":174,"production":2739024},"2006":{"hours":216970,"employees":94,"production":2315541}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":82,"firstDate":"2000-01-24","lastDate":"2011-12-13","metrics":{"recentRows":0,"doseOver100":27,"actDoseTotal":8799,"pelDoseTotal":6909},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"118651","EVENT_NO":"6259315","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"65","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"118616","EVENT_NO":"4061730","SURVEY_DATE":"03/08/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"033","ACT_DOSE_85":"98","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2006-03-08"},{"SOURCE_ROW_NUMBER":"118615","EVENT_NO":"4061730","SURVEY_DATE":"03/08/2006","OCCUPATION_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"36","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2006-03-08"},{"SOURCE_ROW_NUMBER":"118614","EVENT_NO":"4061730","SURVEY_DATE":"03/08/2006","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"59","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2006-03-08"},{"SOURCE_ROW_NUMBER":"118613","EVENT_NO":"4061730","SURVEY_DATE":"03/08/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"21","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2006-03-08"},{"SOURCE_ROW_NUMBER":"118612","EVENT_NO":"4061730","SURVEY_DATE":"03/08/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"47","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2006-03-08"},{"SOURCE_ROW_NUMBER":"118611","EVENT_NO":"4061730","SURVEY_DATE":"03/07/2006","OCCUPATION_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"95","PEL_DOSE_90":"75","SURVEY_TYPE":"I","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"118610","EVENT_NO":"4061730","SURVEY_DATE":"03/07/2006","OCCUPATION_CD_DESC":"HEADGATE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"90","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"118609","EVENT_NO":"4061730","SURVEY_DATE":"03/07/2006","OCCUPATION_CD_DESC":"LONGWALL OPERATOR (HEADGATE SIDE)","MACHINE_CD":"27","MANUFACTURER_CD":"058","ACT_DOSE_85":"120","PEL_DOSE_90":"92","SURVEY_TYPE":"I","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"118608","EVENT_NO":"4061730","SURVEY_DATE":"03/07/2006","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"72","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"118607","EVENT_NO":"4061730","SURVEY_DATE":"03/07/2006","OCCUPATION_CD_DESC":"JACK SETTER (LONGWALL)","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"99","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"118632","EVENT_NO":"4061824","SURVEY_DATE":"10/26/2005","OCCUPATION_CD_DESC":"OUTSIDE FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"10","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2005-10-26"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":190,"firstDate":"2000-01-25","lastDate":"2006-09-20","metrics":{"recentRows":0,"voidSamples":7,"maxQuartzPct":20.7,"validSamples":183,"quartzPctTotal":679.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"89289","CASSETTE_NO":"57669465","SAMPLE_DT":"09/20/2006","QUARTZ_PCT":"03.0","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"140227","CASSETTE_NO":"57618191","SAMPLE_DT":"07/26/2006","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-07-26"},{"SOURCE_ROW_NUMBER":"167411","CASSETTE_NO":"57618186","SAMPLE_DT":"05/11/2006","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-05-11"},{"SOURCE_ROW_NUMBER":"102790","CASSETTE_NO":"57618277","SAMPLE_DT":"04/18/2006","QUARTZ_PCT":"03.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"88086","CASSETTE_NO":"57618290","SAMPLE_DT":"04/18/2006","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"16844","CASSETTE_NO":"57618198","SAMPLE_DT":"04/18/2006","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-18"},{"SOURCE_ROW_NUMBER":"1511","CASSETTE_NO":"57629317","SAMPLE_DT":"04/03/2006","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-04-03"},{"SOURCE_ROW_NUMBER":"153386","CASSETTE_NO":"57609217","SAMPLE_DT":"01/03/2006","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"LONGWALL OPERATOR (TAILGATE SIDE)","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-01-03"},{"SOURCE_ROW_NUMBER":"145029","CASSETTE_NO":"57540556","SAMPLE_DT":"08/16/2005","QUARTZ_PCT":"00.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"INTAKE AIR","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"121892","CASSETTE_NO":"57540542","SAMPLE_DT":"08/16/2005","QUARTZ_PCT":"01.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"69557","CASSETTE_NO":"57540536","SAMPLE_DT":"08/16/2005","QUARTZ_PCT":"00.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-16"},{"SOURCE_ROW_NUMBER":"43839","CASSETTE_NO":"57540578","SAMPLE_DT":"08/16/2005","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-16"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":668,"firstDate":"2000-01-12","lastDate":"2011-12-13","metrics":{"ss":193,"amountDue":90980,"contested":3,"amountPaid":90980,"recentRows":0,"section104d":4,"unterminated":1,"proposedPenalty":95980},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1255747","VIOLATION_NO":"8036332","VIOLATION_ISSUE_DT":"12/13/2011","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/13/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"1255290","VIOLATION_NO":"7112156","VIOLATION_ISSUE_DT":"03/22/2007","SIG_SUB":"N","PART_SECTION":"77.900-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/23/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-03-22"},{"SOURCE_ROW_NUMBER":"1255289","VIOLATION_NO":"7112155","VIOLATION_ISSUE_DT":"03/22/2007","SIG_SUB":"N","PART_SECTION":"75.1711-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/22/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-03-22"},{"SOURCE_ROW_NUMBER":"1255546","VIOLATION_NO":"7110633","VIOLATION_ISSUE_DT":"09/23/2006","SIG_SUB":"Y","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2006","PROPOSED_PENALTY":"350","AMOUNT_DUE":"350","AMOUNT_PAID":"350","CONTESTED_IND":"N","sourceDate":"2006-09-23"},{"SOURCE_ROW_NUMBER":"1255545","VIOLATION_NO":"7110468","VIOLATION_ISSUE_DT":"09/23/2006","SIG_SUB":"N","PART_SECTION":"75.1911(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-23"},{"SOURCE_ROW_NUMBER":"1255544","VIOLATION_NO":"7110467","VIOLATION_ISSUE_DT":"09/23/2006","SIG_SUB":"N","PART_SECTION":"75.1106-5(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-23"},{"SOURCE_ROW_NUMBER":"1255553","VIOLATION_NO":"7112024","VIOLATION_ISSUE_DT":"08/07/2006","SIG_SUB":"N","PART_SECTION":"75.360(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-08-07"},{"SOURCE_ROW_NUMBER":"1255552","VIOLATION_NO":"7112023","VIOLATION_ISSUE_DT":"08/07/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/07/2006","PROPOSED_PENALTY":"324","AMOUNT_DUE":"324","AMOUNT_PAID":"324","CONTESTED_IND":"N","sourceDate":"2006-08-07"},{"SOURCE_ROW_NUMBER":"1255551","VIOLATION_NO":"7112020","VIOLATION_ISSUE_DT":"07/26/2006","SIG_SUB":"N","PART_SECTION":"75.1911(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/26/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-07-26"},{"SOURCE_ROW_NUMBER":"1255550","VIOLATION_NO":"7112019","VIOLATION_ISSUE_DT":"07/26/2006","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/26/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-07-26"},{"SOURCE_ROW_NUMBER":"1255549","VIOLATION_NO":"7112015","VIOLATION_ISSUE_DT":"07/20/2006","SIG_SUB":"N","PART_SECTION":"75.1106-5(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/20/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"1255548","VIOLATION_NO":"7112014","VIOLATION_ISSUE_DT":"07/20/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/20/2006","PROPOSED_PENALTY":"228","AMOUNT_DUE":"228","AMOUNT_PAID":"228","CONTESTED_IND":"N","sourceDate":"2006-07-20"}]}],"safety":{"href":"/api/v1/mines/1800621/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1800621/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","heading":"Testing, examination, and maintenance of circuit breakers; procedures.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.900-1","part":"77","subchapter":"O","subpart":"J","id":"77.900-1","citation":"30 CFR 77.900-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Openings of active mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711-3","part":"75","subchapter":"O","subpart":"R","id":"75.1711-3","citation":"30 CFR 75.1711-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1911","heading":"Fire suppression systems for diesel-powered equipment and fuel transportation units.","id":"75.1911","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1911","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) The fire suppression system required by §§ 75.1907 and 75.1909 shall be a multipurpose dry chemical type (ABC) fire suppression system listed or approved by a nationally recognized independent testing laboratory and appropriate for installation on diesel-powered equipment and fuel transportation units.\n\n(1) The system shall be installed in accordance with the manufacturer's specifications and the limitations of the listing or approval.\n\n(2) The system shall be installed in a protected location or guarded to minimize physical damage from routine vehicle operations.\n\n(3) Suppressant agent distribution tubing or piping shall be secured and protected against damage, including pinching, crimping, stretching, abrasion, and corrosion.\n\n(4) Discharge nozzles shall be positioned and aimed for maximum fire suppression effectiveness. Nozzles shall also be protected against the entrance of foreign materials such as mud, coal dust, or rock dust.\n\n(b) The fire suppression system shall provide fire suppression and, if automatic, fire detection for the engine including the starter, transmission, hydraulic pumps and tanks, fuel tanks, exposed brake units, air compressors and battery areas on diesel-powered equipment and electric panels or controls used on fuel transportation units and other areas as necessary.\n\n(c) If automatic, the fire suppression system shall include audible and visual alarms to warn of fires or system faults.\n\n(d) The fire suppression system shall provide for automatic engine shutdown. If the fire suppression system is automatic, engine shutdown and discharge of suppressant agent may be delayed for a maximum of 15 seconds after the fire is detected by the system.\n\n(e) The fire suppression system shall be operable by at least two manual actuators. One actuator shall be located on each side of the equipment. If the equipment is provided with an operator's compartment, one of the manual actuators shall be located in the compartment within reach of the operator.\n\n(f) The fire suppression system shall remain operative in the event of engine shutdown, equipment electrical system failure, or failure of any other equipment system.\n\n(g) The electrical components of each fire suppression system installed on equipment used where permissible electric equipment is required shall be permissible or intrinsically safe and such components shall be maintained in permissible or intrinsically safe condition.\n\n(h) Electrically operated detection and actuation circuits shall be monitored and provided with status indicators showing power and circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the functional readiness status of the detection system.\n\n(i) Each fire suppression system shall be tested and maintained in accordance with the manufacturer's recommended inspection and maintenance program and as required by the nationally recognized independent testing laboratory listing or approval, and be visually inspected at least once each week by a person trained to make such inspections.\n\n(j) Recordkeeping. Persons performing inspections and tests of fire suppression systems under paragraph (i) shall record when a fire suppression system does not meet the installation or maintenance requirements of this section.\n\n(1) The record shall include the equipment on which the fire suppression system did not meet the installation or maintenance requirements of this section, the defect found, and the corrective action taken.\n\n(2) Records are to be kept manually in a secure manner not susceptible to alteration or recorded electronically in a secured computer system that is not susceptible to alteration.\n\n(3) Records shall be maintained at a surface location at the mine for one year and made available for inspection by an authorized representative of the Secretary and miners' representatives.\n\n(k) All miners normally assigned to the active workings of the mine shall be instructed about the hazards inherent to the operation of the fire suppression systems and, where appropriate, the safeguards available for each system.\n\n(l) For purposes of § 75.380(f), a fire suppression system installed on diesel-powered equipment and meeting the requirements of this section is equivalent to a fire suppression system meeting the requirements of §§ 75.1107-3 through 75.1107-16.","occurrenceCount":2},{"chapter":"I","heading":"Maintenance and tests of liquefied and nonliquefied compressed gas cylinders; accessories and equipment; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-5","part":"75","subchapter":"O","subpart":"L","id":"75.1106-5","citation":"30 CFR 75.1106-5","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1800621","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}