{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1601164","name":"Oxbow Lignite Surface Mine","status":"Abandoned","status_date":"2009-12-30","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Lignite)","state":"LA","county":"Red River","nearest_town":"Armistead","operator_id":"P24526","operator_name":"Red River Mining Company","controller_id":"C01333","controller_name":"NACCO Industries Inc","district":"M5","office":"Broussard LA Field Office","employees":0,"latitude":32.007222,"longitude":-93.403333},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1420},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1601164","name":"Oxbow Lignite Surface Mine"},"operator":{"type":"operator","id":"P24526","name":"Red River Mining Company"},"controller":{"type":"controller","id":"C01333","name":"NACCO Industries Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12631","name":"Phillips Petroleum Company"},"object":{"type":"mine","id":"1601164","name":"Oxbow Lignite Surface Mine"},"validFrom":"1986-07-01","validTo":"1989-01-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|C12631|1986-07-01|1989-01-14"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P18076","name":"Phillips Coal Company"},"object":{"type":"mine","id":"1601164","name":"Oxbow Lignite Surface Mine"},"validFrom":"1988-05-01","validTo":"1989-01-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|P18076|1988-05-01|1989-01-14"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12631","name":"Phillips Petroleum Company"},"object":{"type":"operator","id":"P18076","name":"Phillips Coal Company"},"validFrom":"1988-05-01","validTo":"1989-01-14","current":false,"derived":true,"evidenceMineId":"1601164","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|P18076|1988-05-01|C12631|1986-07-01|87525"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P20224","name":"Red River Mining Company"},"object":{"type":"mine","id":"1601164","name":"Oxbow Lignite Surface Mine"},"validFrom":"1989-01-15","validTo":"2000-10-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|P20224|1989-01-15|2000-10-10"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13791","name":"North American Coal Corp et al"},"object":{"type":"mine","id":"1601164","name":"Oxbow Lignite Surface Mine"},"validFrom":"1989-01-15","validTo":"2000-10-10","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|C13791|1989-01-15|2000-10-10"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13791","name":"North American Coal Corp et al"},"object":{"type":"operator","id":"P20224","name":"Red River Mining Company"},"validFrom":"1989-01-15","validTo":"2000-10-10","current":false,"derived":true,"evidenceMineId":"1601164","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|P20224|1989-01-15|C13791|1989-01-15|91136"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24526","name":"Red River Mining Company"},"object":{"type":"mine","id":"1601164","name":"Oxbow Lignite Surface Mine"},"validFrom":"2000-10-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|P24526|2000-10-11|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C01333","name":"NACCO Industries Inc"},"object":{"type":"mine","id":"1601164","name":"Oxbow Lignite Surface Mine"},"validFrom":"2000-10-11","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|C01333|2000-10-11|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C01333","name":"NACCO Industries Inc"},"object":{"type":"operator","id":"P24526","name":"Red River Mining Company"},"validFrom":"2000-10-11","validTo":null,"current":true,"derived":true,"evidenceMineId":"1601164","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1601164|P24526|2000-10-11|C01333|2000-10-11|53610"}}],"coverage":{"historyRecords":3,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":11,"firstDate":"2001-11-09","lastDate":"2009-10-02","metrics":{"daysLost":216,"injuries":11,"fatalities":0,"recentRows":0,"restrictedDays":4,"contractorRecords":3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"221038","DOCUMENT_NO":"220092860042","ACCIDENT_DT":"10/02/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was working on the left rear final drive of a 777 haul truck when he felt pain in his back, between the shoulder blades.  The employee missed the next two scheduled shifts then returned to work.","sourceDate":"2009-10-02"},{"SOURCE_ROW_NUMBER":"173648","DOCUMENT_NO":"220090640014","ACCIDENT_DT":"02/23/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"17","NARRATIVE":"Employee mounted and dismounted multiple pieces of equipment, around noon his ankle started hurting.  He was taken to medical facilities and had a sprained ankle.  The individual does not know of a specific incident that contributed to the sprain.","sourceDate":"2009-02-23"},{"SOURCE_ROW_NUMBER":"1680","DOCUMENT_NO":"220053550025","ACCIDENT_DT":"12/12/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Quality control technician, Laboratory technician, Laboratory assistant","NO_INJURIES":"1","DAYS_LOST":"102","NARRATIVE":"The operator of a 777Cat Haul Truck hit a soft spot in the haul road at an excessive speed, this resulted in a fracture to the operators right wrist, and a laceration to his chin.  Note:  The operator was wearing his seatbelt, also, the operator had been through the soft spot 4 times prior to the accident, and was contacted approx 1 minute prior to the accident about the soft spot.","sourceDate":"2005-12-12"},{"SOURCE_ROW_NUMBER":"199393","DOCUMENT_NO":"220050120016","ACCIDENT_DT":"12/30/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Quality control technician, Laboratory technician, Laboratory assistant","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While cutting the jacket off a piece of lectrical wire, the person cut their Left hand thumb.  The cut required 3 stitches. The cut was a result of the person cutting toward the hand they were hold the wire with.","sourceDate":"2004-12-30"},{"SOURCE_ROW_NUMBER":"190797","DOCUMENT_NO":"220050240016","ACCIDENT_DT":"12/29/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from scaffolds, walkways, platforms","OCCUPATION":"Haul/Off road/Coal/Ore/Pit/Quarry/Rock/Rubber tire truck driver, Transportation truck driver","NO_INJURIES":"1","DAYS_LOST":"81","NARRATIVE":"Employee was in the process of loading coal and stepped off the loading platform when he slipped and fell.  Resulted in sprain/strain to the neck and upper back.","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"130437","DOCUMENT_NO":"220042800013","ACCIDENT_DT":"09/29/2004","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"Officer pulled up to office in patrol truck.  He exited the vehicle and stepped on a clod of dirt causing his ankle to twist.","sourceDate":"2004-09-29"},{"SOURCE_ROW_NUMBER":"251182","DOCUMENT_NO":"220042390021","ACCIDENT_DT":"08/18/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While grinding on a piece of metal a shard of metal became embedded in the welders right eye.  The welder was wearing his welders hood at the time.","sourceDate":"2004-08-18"},{"SOURCE_ROW_NUMBER":"225275","DOCUMENT_NO":"220042080001","ACCIDENT_DT":"07/22/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While tightening a hose clamp with an air impact wrench and a Snap-On 15/16 IPL30B Socket(swivel-type), the mechanic was holding the socket onto the bolt when the swivel pin broke, the socket seperated and part of the socket caught the mechanics Left hand Index finger, cutting it.  This injury required Four stitches.","sourceDate":"2004-07-22"},{"SOURCE_ROW_NUMBER":"221037","DOCUMENT_NO":"220020840113","ACCIDENT_DT":"03/21/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Welder (shop)","NO_INJURIES":"1","NARRATIVE":"EE WAS UP UNDER THE 9N DOZER CUTTING ROLLER FLANGES OFF. IN DOING THIS, A PIECE OF THE ROLLER FLANGE FELL OFF AND GOT CAUGHT BETWEEN HIS WRIST AND GLOVE, BURNING HIS LEFT WRIST.","sourceDate":"2002-03-21"},{"SOURCE_ROW_NUMBER":"225274","DOCUMENT_NO":"220020700145","ACCIDENT_DT":"03/04/2002","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Mine manager, Mine foreman, Mine owner","NO_INJURIES":"1","NARRATIVE":"SUPERVISOR WAS WORKING ON THE TOUR BUS AND TRASH FELL UNDER SAFETY GLASSES INTO EYE.","sourceDate":"2002-03-04"},{"SOURCE_ROW_NUMBER":"44603","DOCUMENT_NO":"220013320026","ACCIDENT_DT":"11/09/2001","DEGREE_INJURY":"INJURIES DUE TO NATURAL CAUSES","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"NEC","OCCUPATION":"Assayer, Geologist, Metallurgist, Engineer, Engineer management","NO_INJURIES":"1","NARRATIVE":"EMPLOYEE REPORTED TO HAVE FELT ILL, CHEST PAINS AND INDIGESTION. HE LEFT JOB SITE AND WAS TRAVELING HOME. HE DECIDED TO GO TO HOSPITAL WHEN IN TRANSIT AND WAS DIAGNOSED WITH A HEART ATTACK. JOBSITE TO HOME TRANSIT WAS FROM COUSHATTA LA TO BOGOTA TX.","sourceDate":"2001-11-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-12-30","lastDate":"2009-12-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":15,"firstDate":"2000-04-26","lastDate":"2009-08-27","metrics":{"ss":0,"delinquent":15,"recentRows":0,"paidPenalty":1070,"proposedPenalty":1070,"currentAssessment":1070},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1223473","VIOLATION_NO":"8465804","ISSUE_DT":"08/27/2009","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-27"},{"SOURCE_ROW_NUMBER":"1223352","VIOLATION_NO":"7289683","ISSUE_DT":"12/04/2008","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"1223351","VIOLATION_NO":"7289682","ISSUE_DT":"12/04/2008","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"1223350","VIOLATION_NO":"7289681","ISSUE_DT":"12/03/2008","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"1223349","VIOLATION_NO":"7289680","ISSUE_DT":"12/03/2008","CFR_STANDARD_CD":"77.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"1215700","VIOLATION_NO":"7601787","ISSUE_DT":"03/04/2004","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1215699","VIOLATION_NO":"7601786","ISSUE_DT":"03/04/2004","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1215698","VIOLATION_NO":"7601785","ISSUE_DT":"03/04/2004","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1215697","VIOLATION_NO":"7601784","ISSUE_DT":"03/04/2004","CFR_STANDARD_CD":"77.1710(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1215170","VIOLATION_NO":"7601444","ISSUE_DT":"02/12/2003","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-02-12"},{"SOURCE_ROW_NUMBER":"1215169","VIOLATION_NO":"7601443","ISSUE_DT":"02/11/2003","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2003-02-11"},{"SOURCE_ROW_NUMBER":"1214617","VIOLATION_NO":"7601102","ISSUE_DT":"10/10/2001","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2001-10-10"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2009-02-10","lastDate":"2009-02-10","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":0,"originalPenalty":100},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"274499","VIOLATION_NO":"7291588","DOCKET_NO":"CENT 2008-610","DECISION_DT":"02/10/2009","DECISION_TYPE_CODE_DESC":"Withdrawal","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"0.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2009-02-10"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":77,"firstDate":"2000-04-26","lastDate":"2008-12-04","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":4,"validSamples":73,"maxConcentration":1.585,"concentrationTotal":20.502},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1225738","CASS_NUM":"57734519","SMP_TAKEN_DT":"12/4/2008","CONC":".061","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"1135086","CASS_NUM":"57734507","SMP_TAKEN_DT":"12/4/2008","CONC":".094","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"943689","CASS_NUM":"57734558","SMP_TAKEN_DT":"12/4/2008","CONC":".044","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"640672","CASS_NUM":"57734523","SMP_TAKEN_DT":"12/4/2008","CONC":".038","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"398072","CASS_NUM":"57734505","SMP_TAKEN_DT":"12/4/2008","CONC":".041","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"PUMPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"1338049","CASS_NUM":"57641744","SMP_TAKEN_DT":"8/9/2006","CONC":".044","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-09"},{"SOURCE_ROW_NUMBER":"1046690","CASS_NUM":"57641713","SMP_TAKEN_DT":"8/9/2006","CONC":".034","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-09"},{"SOURCE_ROW_NUMBER":"766047","CASS_NUM":"57641710","SMP_TAKEN_DT":"8/9/2006","CONC":".198","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-09"},{"SOURCE_ROW_NUMBER":"626574","CASS_NUM":"57641708","SMP_TAKEN_DT":"8/9/2006","CONC":".071","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROAD GRADER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-09"},{"SOURCE_ROW_NUMBER":"273177","CASS_NUM":"57641739","SMP_TAKEN_DT":"8/9/2006","CONC":".586","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-08-09"},{"SOURCE_ROW_NUMBER":"1393596","CASS_NUM":"57598368","SMP_TAKEN_DT":"3/31/2006","CONC":".51","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BACKHOE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-31"},{"SOURCE_ROW_NUMBER":"1205439","CASS_NUM":"57598383","SMP_TAKEN_DT":"3/31/2006","CONC":".129","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL TRUCK DRIVER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-31"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2008-02-21","lastDate":"2008-02-21","metrics":{"decisions":1,"ssChanged":1,"recentRows":0,"decisionPenalty":0,"proposedPenalty":100},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"232354","CITATION_NO":"7291588","CITATION_ISSUE_DT":"02/21/2008","DOCKET_NO":"CENT 2008-610","DECISION_DT":"02/10/2009","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":".00","sourceDate":"2008-02-21"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":940,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":225,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"1988-05-01","lastDate":"2000-10-11","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":37,"firstDate":"2000-04-25","lastDate":"2009-08-27","metrics":{"inspectors":38,"recentRows":0,"onSiteHours":371.5,"inspectionHours":776.5,"inspectionSamples":29},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"205504","EVENT_NO":"4263845","INSPECTION_BEGIN_DT":"08/27/2009","INSPECTION_END_DT":"08/31/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"34.5","SUM_TOTAL_ON_SITE_HOURS":"20.5","sourceDate":"2009-08-27"},{"SOURCE_ROW_NUMBER":"273346","EVENT_NO":"4263829","INSPECTION_BEGIN_DT":"12/01/2008","INSPECTION_END_DT":"12/05/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"44","SUM_TOTAL_ON_SITE_HOURS":"18.5","sourceDate":"2008-12-01"},{"SOURCE_ROW_NUMBER":"802122","EVENT_NO":"4261110","INSPECTION_BEGIN_DT":"04/30/2008","INSPECTION_END_DT":"04/30/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"776783","EVENT_NO":"4477775","INSPECTION_BEGIN_DT":"02/14/2008","INSPECTION_END_DT":"02/26/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"51","SUM_TOTAL_ON_SITE_HOURS":"17","sourceDate":"2008-02-14"},{"SOURCE_ROW_NUMBER":"160510","EVENT_NO":"4260865","INSPECTION_BEGIN_DT":"07/17/2007","INSPECTION_END_DT":"07/24/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2007-07-17"},{"SOURCE_ROW_NUMBER":"642401","EVENT_NO":"4477748","INSPECTION_BEGIN_DT":"01/17/2007","INSPECTION_END_DT":"01/31/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"49.5","SUM_TOTAL_ON_SITE_HOURS":"15.5","sourceDate":"2007-01-17"},{"SOURCE_ROW_NUMBER":"303413","EVENT_NO":"4260767","INSPECTION_BEGIN_DT":"08/08/2006","INSPECTION_END_DT":"08/10/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2006-08-08"},{"SOURCE_ROW_NUMBER":"821619","EVENT_NO":"4477733","INSPECTION_BEGIN_DT":"01/19/2006","INSPECTION_END_DT":"03/31/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"47","SUM_TOTAL_ON_SITE_HOURS":"23","sourceDate":"2006-01-19"},{"SOURCE_ROW_NUMBER":"185198","EVENT_NO":"4260452","INSPECTION_BEGIN_DT":"09/08/2005","INSPECTION_END_DT":"09/19/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"28.5","SUM_TOTAL_ON_SITE_HOURS":"16.5","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"416606","EVENT_NO":"4260201","INSPECTION_BEGIN_DT":"03/31/2005","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"BAF","ACTIVITY":"RESP DUST TECH INSP - SURFACE MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2005-03-31"},{"SOURCE_ROW_NUMBER":"67672","EVENT_NO":"4260192","INSPECTION_BEGIN_DT":"02/22/2005","INSPECTION_END_DT":"02/24/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"22.5","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2005-02-22"},{"SOURCE_ROW_NUMBER":"363268","EVENT_NO":"4260177","INSPECTION_BEGIN_DT":"12/14/2004","INSPECTION_END_DT":"12/14/2004","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2004-12-14"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002-Q4":{"hours":16940,"employees":34,"production":166791},"2002-Q3":{"hours":18929,"employees":37,"production":149757},"2002-Q2":{"hours":19625,"employees":37,"production":119611},"2002-Q1":{"hours":17724,"employees":37,"production":173042},"2001-Q4":{"hours":20695,"employees":40,"production":225904},"2001-Q3":{"hours":21986,"employees":39,"production":218524},"2001-Q2":{"hours":20963,"employees":39,"production":183980},"2001-Q1":{"hours":20745,"employees":38,"production":283972},"2000-Q4":{"hours":19419,"employees":39,"production":243126},"2000-Q3":{"hours":20672,"employees":39,"production":252349},"2000-Q2":{"hours":19464,"employees":37,"production":174792},"2000-Q1":{"hours":16104,"employees":39,"production":102771}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2000":{"hours":75659,"employees":39,"production":773038},"2001":{"hours":84389,"employees":39,"production":912380},"2002":{"hours":73218,"employees":36,"production":609201},"2003":{"hours":67997,"employees":34,"production":563619},"2004":{"hours":65247,"employees":33,"production":540468},"2005":{"hours":75927,"employees":36,"production":598458},"2006":{"hours":88937,"employees":39,"production":783138},"2007":{"hours":85454,"employees":40,"production":504008},"2008":{"hours":76817,"employees":40,"production":558584},"2009":{"hours":101260,"employees":50,"production":681816}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":41,"firstDate":"2000-04-26","lastDate":"2009-08-28","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":1931,"pelDoseTotal":1182},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"117668","EVENT_NO":"4263845","SURVEY_DATE":"08/28/2009","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"76","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2009-08-28"},{"SOURCE_ROW_NUMBER":"117667","EVENT_NO":"4263845","SURVEY_DATE":"08/28/2009","OCCUPATION_CD_DESC":"STRIPPING SHOVEL OPERATOR","MACHINE_CD":"35","MANUFACTURER_CD":"027","ACT_DOSE_85":"23","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2009-08-28"},{"SOURCE_ROW_NUMBER":"117666","EVENT_NO":"4263845","SURVEY_DATE":"08/28/2009","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"55","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2009-08-28"},{"SOURCE_ROW_NUMBER":"117665","EVENT_NO":"4263829","SURVEY_DATE":"12/04/2008","OCCUPATION_CD_DESC":"MINE FOREMAN/MINE MANAGER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"9","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"117664","EVENT_NO":"4263829","SURVEY_DATE":"12/04/2008","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"8","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"117663","EVENT_NO":"4263829","SURVEY_DATE":"12/04/2008","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"117662","EVENT_NO":"4263829","SURVEY_DATE":"12/04/2008","OCCUPATION_CD_DESC":"WELDER (NON-SHOP)","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"13","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"117661","EVENT_NO":"4263829","SURVEY_DATE":"12/04/2008","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"22","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"117672","EVENT_NO":"4477775","SURVEY_DATE":"02/21/2008","OCCUPATION_CD_DESC":"WELDER (SHOP)","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"45","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2008-02-21"},{"SOURCE_ROW_NUMBER":"117671","EVENT_NO":"4477775","SURVEY_DATE":"02/21/2008","OCCUPATION_CD_DESC":"OILER/GREASER","MACHINE_CD":"12","MANUFACTURER_CD":"070","ACT_DOSE_85":"110","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2008-02-21"},{"SOURCE_ROW_NUMBER":"117670","EVENT_NO":"4477775","SURVEY_DATE":"02/21/2008","OCCUPATION_CD_DESC":"TIPPLE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"46","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2008-02-21"},{"SOURCE_ROW_NUMBER":"117669","EVENT_NO":"4477775","SURVEY_DATE":"02/21/2008","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"01","MANUFACTURER_CD":"018","ACT_DOSE_85":"19","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2008-02-21"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":4,"firstDate":"2003-02-12","lastDate":"2004-03-30","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.6,"validSamples":4,"quartzPctTotal":7.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"53697","CASSETTE_NO":"57444018","SAMPLE_DT":"03/30/2004","QUARTZ_PCT":"00.6","OCC_CODE_DESC":"BACKHOE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-03-30"},{"SOURCE_ROW_NUMBER":"55222","CASSETTE_NO":"50696236","SAMPLE_DT":"04/29/2003","QUARTZ_PCT":"00.2","OCC_CODE_DESC":"COAL SHOVEL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-04-29"},{"SOURCE_ROW_NUMBER":"105669","CASSETTE_NO":"50696286","SAMPLE_DT":"03/25/2003","QUARTZ_PCT":"00.4","OCC_CODE_DESC":"COAL SHOVEL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-03-25"},{"SOURCE_ROW_NUMBER":"101347","CASSETTE_NO":"57443906","SAMPLE_DT":"02/12/2003","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"COAL SHOVEL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2003-02-12"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":15,"firstDate":"2000-04-26","lastDate":"2009-08-27","metrics":{"ss":0,"amountDue":1070,"contested":0,"amountPaid":1070,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":1070},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1221917","VIOLATION_NO":"8465804","VIOLATION_ISSUE_DT":"08/27/2009","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/27/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-08-27"},{"SOURCE_ROW_NUMBER":"1221923","VIOLATION_NO":"7289683","VIOLATION_ISSUE_DT":"12/04/2008","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"1221922","VIOLATION_NO":"7289682","VIOLATION_ISSUE_DT":"12/04/2008","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-12-04"},{"SOURCE_ROW_NUMBER":"1221921","VIOLATION_NO":"7289681","VIOLATION_ISSUE_DT":"12/03/2008","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"1221920","VIOLATION_NO":"7289680","VIOLATION_ISSUE_DT":"12/03/2008","SIG_SUB":"N","PART_SECTION":"77.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/03/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"1221914","VIOLATION_NO":"7601787","VIOLATION_ISSUE_DT":"03/04/2004","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1221913","VIOLATION_NO":"7601786","VIOLATION_ISSUE_DT":"03/04/2004","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1221912","VIOLATION_NO":"7601785","VIOLATION_ISSUE_DT":"03/04/2004","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1221911","VIOLATION_NO":"7601784","VIOLATION_ISSUE_DT":"03/04/2004","SIG_SUB":"N","PART_SECTION":"77.1710(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/04/2004","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2004-03-04"},{"SOURCE_ROW_NUMBER":"1221910","VIOLATION_NO":"7601444","VIOLATION_ISSUE_DT":"02/12/2003","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-02-12"},{"SOURCE_ROW_NUMBER":"1221909","VIOLATION_NO":"7601443","VIOLATION_ISSUE_DT":"02/11/2003","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2003","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2003-02-11"},{"SOURCE_ROW_NUMBER":"1221918","VIOLATION_NO":"7601102","VIOLATION_ISSUE_DT":"10/10/2001","SIG_SUB":"N","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/10/2001","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2001-10-10"}]}],"safety":{"href":"/api/v1/mines/1601164/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1601164/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.512","heading":"Inspection and cover plates.","id":"77.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.512","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Inspection and cover plates on electrical equipment shall be kept in place at all times except during testing or repairs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":4},{"chapter":"I","heading":"Protective clothing; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1710","part":"77","subchapter":"O","subpart":"R","id":"77.1710","citation":"30 CFR 77.1710","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1601164","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}