{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1519768","name":"Jennie Branch Mine","status":"Abandoned","status_date":"2019-09-20","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Bell","nearest_town":"Miracle","operator_id":"0135993","operator_name":"Tennco, Inc.","controller_id":"0124921","controller_name":"Jack  Stump; Michael  Runyon","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.725278,"longitude":-83.544722},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1786},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519768","name":"Jennie Branch Mine"},"operator":{"type":"operator","id":"0135993","name":"Tennco, Inc."},"controller":{"type":"controller","id":"0124921","name":"Jack  Stump; Michael  Runyon"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0135993","name":"Tennco, Inc."},"object":{"type":"mine","id":"1519768","name":"Jennie Branch Mine"},"validFrom":"2014-11-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|0135993|2014-11-17|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03319","name":"Daris  Stump"},"object":{"type":"mine","id":"1519768","name":"Jennie Branch Mine"},"validFrom":"2014-11-17","validTo":"2015-02-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|C03319|2014-11-17|2015-02-15"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03319","name":"Daris  Stump"},"object":{"type":"operator","id":"0135993","name":"Tennco, Inc."},"validFrom":"2014-11-17","validTo":"2015-02-15","current":false,"derived":true,"evidenceMineId":"1519768","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|0135993|2014-11-17|C03319|2014-11-17|62500"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15892","name":"Jack  Stump Et Al"},"object":{"type":"mine","id":"1519768","name":"Jennie Branch Mine"},"validFrom":"2015-02-16","validTo":"2016-03-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|C15892|2015-02-16|2016-03-30"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15892","name":"Jack  Stump Et Al"},"object":{"type":"operator","id":"0135993","name":"Tennco, Inc."},"validFrom":"2015-02-16","validTo":"2016-03-30","current":false,"derived":true,"evidenceMineId":"1519768","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|0135993|2014-11-17|C15892|2015-02-16|97522"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15892","name":"Jackie (Mitch)  Fannin Et Al"},"object":{"type":"operator","id":"0135993","name":"Tennco, Inc."},"validFrom":"2015-02-16","validTo":"2016-03-30","current":false,"derived":true,"evidenceMineId":"1519768","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|0135993|2014-11-17|C15892|2015-02-16|97523"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0124921","name":"Michael  Runyon et al"},"object":{"type":"mine","id":"1519768","name":"Jennie Branch Mine"},"validFrom":"2016-03-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|0124921|2016-03-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0124921","name":"Michael  Runyon et al"},"object":{"type":"operator","id":"0135993","name":"Tennco, Inc."},"validFrom":"2016-03-31","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519768","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|0135993|2014-11-17|0124921|2016-03-31|24237"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0124921","name":"Jack  Stump et al"},"object":{"type":"operator","id":"0135993","name":"Tennco, Inc."},"validFrom":"2016-03-31","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519768","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519768|0135993|2014-11-17|0124921|2016-03-31|24238"}}],"coverage":{"historyRecords":5,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":10,"firstDate":"2015-01-13","lastDate":"2018-03-16","metrics":{"daysLost":40,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":80,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"113288","DOCUMENT_NO":"220180860006","ACCIDENT_DT":"03/16/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Miner was riding the mantrip when it struck a coal rib causing a piece of coal rib to strike a miner in the lower left side back. This accident was not reported to mine management until 03/22/2018. The miner involved worked this shift and the next shift. Miner went to the Doctor on 03/19/2018 and returned to work on 03/22/2018 when they reported this happened at work.","sourceDate":"2018-03-16"},{"SOURCE_ROW_NUMBER":"44566","DOCUMENT_NO":"220173030026","ACCIDENT_DT":"10/20/2017","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Roof Fall in the 2nd north west mains, approximately 250 feet inby spad 1169 between a cribbed area and a solid coal rib. The fall is approximately 10 feet wide, 6 feet high and 30 feet long","sourceDate":"2017-10-20"},{"SOURCE_ROW_NUMBER":"177987","DOCUMENT_NO":"220173030024","ACCIDENT_DT":"10/18/2017","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Roof fall in 2nd North west mains approximately 325 feet inby spad 1168. Fall does not affect ventilation or passage of miners. The fall is approximately 18 feet wide, 7 feet high and 60 feet long and does take in an intersection that abuts a solid coal rib.","sourceDate":"2017-10-18"},{"SOURCE_ROW_NUMBER":"87637","DOCUMENT_NO":"220160490011","ACCIDENT_DT":"02/11/2016","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using a slate bar to remove a loose rib as deemed by MSHA Inspector and EE's Supervisor when EE strained EE's groin trying to remove the rib.","sourceDate":"2016-02-11"},{"SOURCE_ROW_NUMBER":"272566","DOCUMENT_NO":"220160490018","ACCIDENT_DT":"10/11/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Foreman ran into a miner cable that was hung in an intersection on the 11th and 12th. He continued working without being off or seeing a doctor until he was laid off on December 1, 2015. EE had to seek medical attention for his neck February 11, 2016. He reported the injury to mine management again on February 17, 2016","sourceDate":"2015-10-11"},{"SOURCE_ROW_NUMBER":"246874","DOCUMENT_NO":"220152640036","ACCIDENT_DT":"09/11/2015","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"35","NARRATIVE":"The employee was checking a shuttle car tire in the #3 entry 2 crosscuts outby the face when a piece of rib coal rolled off knocking him off balance causing pushing him into the shuttle car and catching him between the car and the coal rib.","sourceDate":"2015-09-11"},{"SOURCE_ROW_NUMBER":"96047","DOCUMENT_NO":"220151950014","ACCIDENT_DT":"06/25/2015","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Roof Bolting Machine operator was installing 8 foot rope bolts. As he was placing the bolt in the hole and pushing it into place he accidently hit the rotation lever on the drill. As the bolt begin to spin a strand of wire or metal broke away from the bolt and entered the right hand of the machine operator.","sourceDate":"2015-06-25"},{"SOURCE_ROW_NUMBER":"18790","DOCUMENT_NO":"220151190024","ACCIDENT_DT":"04/16/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"The employee is a roof bolt machine operator and was working in the number 4 entry of the 001 section. EE was installing the inside roof bolt when a piece of roof rock broke loose and struck EE's left foot. The rock was approximately 2'X 1'and from 0 to 5 inches thick.","sourceDate":"2015-04-16"},{"SOURCE_ROW_NUMBER":"70317","DOCUMENT_NO":"220150920018","ACCIDENT_DT":"03/21/2015","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred in the number 4 portal (fan) intake air course entry approximately 18 feet wide, 10 feet high and 60 to 70 feet in length. The cause of the fall was due to the extremely harsh winter weather of late where the roof froze and thawed several. This fall was immediately report to MSHA via the 800 number.","sourceDate":"2015-03-21"},{"SOURCE_ROW_NUMBER":"190770","DOCUMENT_NO":"220150150010","ACCIDENT_DT":"01/13/2015","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Freezing and thawing of highwall at portal","sourceDate":"2015-01-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2019-09-20","lastDate":"2019-09-20","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":244,"firstDate":"2015-02-04","lastDate":"2018-12-03","metrics":{"ss":62,"delinquent":216,"recentRows":0,"paidPenalty":49356,"proposedPenalty":50973,"currentAssessment":49356},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1473444","VIOLATION_NO":"9136624","ISSUE_DT":"12/03/2018","CFR_STANDARD_CD":"75.380(d)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"405.00","CURRENT_ASSESSMENT_AMT":"405.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-12-03"},{"SOURCE_ROW_NUMBER":"1473443","VIOLATION_NO":"9136623","ISSUE_DT":"11/28/2018","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-11-28"},{"SOURCE_ROW_NUMBER":"1473442","VIOLATION_NO":"9136622","ISSUE_DT":"11/15/2018","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-11-15"},{"SOURCE_ROW_NUMBER":"1473441","VIOLATION_NO":"9136621","ISSUE_DT":"11/15/2018","CFR_STANDARD_CD":"77.500","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-11-15"},{"SOURCE_ROW_NUMBER":"1473440","VIOLATION_NO":"9136620","ISSUE_DT":"11/07/2018","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"395.00","CURRENT_ASSESSMENT_AMT":"395.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-11-07"},{"SOURCE_ROW_NUMBER":"1473439","VIOLATION_NO":"9136619","ISSUE_DT":"11/05/2018","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-11-05"},{"SOURCE_ROW_NUMBER":"1473438","VIOLATION_NO":"9136611","ISSUE_DT":"10/10/2018","CFR_STANDARD_CD":"75.1722(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-10-10"},{"SOURCE_ROW_NUMBER":"1473437","VIOLATION_NO":"9136610","ISSUE_DT":"10/04/2018","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-10-04"},{"SOURCE_ROW_NUMBER":"1473436","VIOLATION_NO":"9136609","ISSUE_DT":"10/04/2018","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-10-04"},{"SOURCE_ROW_NUMBER":"1480733","VIOLATION_NO":"9136511","ISSUE_DT":"08/13/2018","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-08-13"},{"SOURCE_ROW_NUMBER":"1480732","VIOLATION_NO":"9136510","ISSUE_DT":"08/08/2018","CFR_STANDARD_CD":"75.211(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"395.00","CURRENT_ASSESSMENT_AMT":"395.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-08-08"},{"SOURCE_ROW_NUMBER":"1480731","VIOLATION_NO":"9136509","ISSUE_DT":"08/06/2018","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-08-06"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":7,"firstDate":"2017-06-27","lastDate":"2017-07-26","metrics":{"appeals":0,"decisions":7,"recentRows":0,"decisionPenalty":10121,"originalPenalty":11738},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"409093","VIOLATION_NO":"8373678","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"380.00","DECISION_PENALTY_AMT":"380.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2017-07-26"},{"SOURCE_ROW_NUMBER":"409092","VIOLATION_NO":"8373677","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"568.00","DECISION_PENALTY_AMT":"255.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2017-07-26"},{"SOURCE_ROW_NUMBER":"409091","VIOLATION_NO":"8373675","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"380.00","DECISION_PENALTY_AMT":"171.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2017-07-26"},{"SOURCE_ROW_NUMBER":"166892","VIOLATION_NO":"8373684","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"722.00","DECISION_PENALTY_AMT":"722.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2017-07-26"},{"SOURCE_ROW_NUMBER":"168058","VIOLATION_NO":"8373685","DOCKET_NO":"KENT 2017-0133","DECISION_DT":"06/28/2017","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5475.00","DECISION_PENALTY_AMT":"4380.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2017-06-28"},{"SOURCE_ROW_NUMBER":"168209","VIOLATION_NO":"8373708","DOCKET_NO":"KENT 2017-0175","DECISION_DT":"06/27/2017","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"577.00","DECISION_PENALTY_AMT":"577.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-06-27"},{"SOURCE_ROW_NUMBER":"168153","VIOLATION_NO":"8373702","DOCKET_NO":"KENT 2017-0175","DECISION_DT":"06/27/2017","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"3636.00","DECISION_PENALTY_AMT":"3636.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-06-27"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":783,"firstDate":"2013-05-12","lastDate":"2018-10-26","metrics":{"recentRows":0,"cpdmSamples":580,"voidSamples":85,"validSamples":698,"maxConcentration":1.662,"concentrationTotal":322.268},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2543325","SMP_TAKEN_DT":"10/26/2018","CONC":".125","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-26"},{"SOURCE_ROW_NUMBER":"2543324","SMP_TAKEN_DT":"10/26/2018","CONC":".253","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-26"},{"SOURCE_ROW_NUMBER":"2544306","SMP_TAKEN_DT":"10/25/2018","CONC":".794","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-25"},{"SOURCE_ROW_NUMBER":"1775710","SMP_TAKEN_DT":"10/25/2018","CONC":".204","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-25"},{"SOURCE_ROW_NUMBER":"2201438","SMP_TAKEN_DT":"10/24/2018","CONC":".362","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-24"},{"SOURCE_ROW_NUMBER":"2030290","SMP_TAKEN_DT":"10/24/2018","CONC":".162","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-24"},{"SOURCE_ROW_NUMBER":"2799765","SMP_TAKEN_DT":"10/23/2018","CONC":".171","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-23"},{"SOURCE_ROW_NUMBER":"2457591","SMP_TAKEN_DT":"10/23/2018","CONC":".123","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-23"},{"SOURCE_ROW_NUMBER":"2885291","SMP_TAKEN_DT":"10/22/2018","CONC":".218","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-22"},{"SOURCE_ROW_NUMBER":"2115295","SMP_TAKEN_DT":"10/19/2018","CONC":".336","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-19"},{"SOURCE_ROW_NUMBER":"1774236","SMP_TAKEN_DT":"10/19/2018","CONC":".085","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-19"},{"SOURCE_ROW_NUMBER":"2800054","SMP_TAKEN_DT":"10/18/2018","CONC":".206","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2018-10-18"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2015-09-30","lastDate":"2017-11-30","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":7,"firstDate":"2016-11-08","lastDate":"2017-01-31","metrics":{"decisions":7,"ssChanged":2,"recentRows":0,"decisionPenalty":10121,"proposedPenalty":11738},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"211836","CITATION_NO":"8373708","CITATION_ISSUE_DT":"01/31/2017","DOCKET_NO":"KENT 2017-0175","DECISION_DT":"06/27/2017","CFR_STANDARD_CODE":"62.130(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"577.00","DECISION_PENALTY_AMT":"577.00","sourceDate":"2017-01-31"},{"SOURCE_ROW_NUMBER":"156935","CITATION_NO":"8373702","CITATION_ISSUE_DT":"01/10/2017","DOCKET_NO":"KENT 2017-0175","DECISION_DT":"06/27/2017","CFR_STANDARD_CODE":"75.523","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3636.00","DECISION_PENALTY_AMT":"3636.00","sourceDate":"2017-01-10"},{"SOURCE_ROW_NUMBER":"323209","CITATION_NO":"8373684","CITATION_ISSUE_DT":"11/28/2016","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","CFR_STANDARD_CODE":"75.220(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"722.00","DECISION_PENALTY_AMT":"722.00","sourceDate":"2016-11-28"},{"SOURCE_ROW_NUMBER":"155714","CITATION_NO":"8373685","CITATION_ISSUE_DT":"11/28/2016","DOCKET_NO":"KENT 2017-0133","DECISION_DT":"06/28/2017","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5475.00","DECISION_PENALTY_AMT":"4380.00","sourceDate":"2016-11-28"},{"SOURCE_ROW_NUMBER":"438802","CITATION_NO":"8373677","CITATION_ISSUE_DT":"11/08/2016","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","CFR_STANDARD_CODE":"75.1722(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"568.00","DECISION_PENALTY_AMT":"255.00","sourceDate":"2016-11-08"},{"SOURCE_ROW_NUMBER":"266861","CITATION_NO":"8373678","CITATION_ISSUE_DT":"11/08/2016","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"380.00","DECISION_PENALTY_AMT":"380.00","sourceDate":"2016-11-08"},{"SOURCE_ROW_NUMBER":"264330","CITATION_NO":"8373675","CITATION_ISSUE_DT":"11/08/2016","DOCKET_NO":"KENT 2017-0132","DECISION_DT":"07/26/2017","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"380.00","DECISION_PENALTY_AMT":"171.00","sourceDate":"2016-11-08"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":237,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":47,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2014-11-17","lastDate":"2014-11-17","metrics":{"recentRows":0,"currentOperatorTenures":5,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":48,"firstDate":"2015-01-05","lastDate":"2019-07-08","metrics":{"inspectors":130,"recentRows":0,"onSiteHours":2497.25,"inspectionHours":3953,"inspectionSamples":584},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"300399","EVENT_NO":"4459451","INSPECTION_BEGIN_DT":"07/08/2019","INSPECTION_END_DT":"07/11/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2019-07-08"},{"SOURCE_ROW_NUMBER":"403351","EVENT_NO":"4456994","INSPECTION_BEGIN_DT":"06/03/2019","INSPECTION_END_DT":"06/03/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2019-06-03"},{"SOURCE_ROW_NUMBER":"351279","EVENT_NO":"4454423","INSPECTION_BEGIN_DT":"02/26/2019","INSPECTION_END_DT":"02/28/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2019-02-26"},{"SOURCE_ROW_NUMBER":"978407","EVENT_NO":"4454414","INSPECTION_BEGIN_DT":"10/01/2018","INSPECTION_END_DT":"12/06/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"226","SUM_TOTAL_ON_SITE_HOURS":"145.25","sourceDate":"2018-10-01"},{"SOURCE_ROW_NUMBER":"1129669","EVENT_NO":"4456807","INSPECTION_BEGIN_DT":"09/25/2018","INSPECTION_END_DT":"09/26/2018","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"37","SUM_TOTAL_ON_SITE_HOURS":"24.5","sourceDate":"2018-09-25"},{"SOURCE_ROW_NUMBER":"291884","EVENT_NO":"4456877","INSPECTION_BEGIN_DT":"07/03/2018","INSPECTION_END_DT":"09/10/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"249.25","SUM_TOTAL_ON_SITE_HOURS":"166.25","sourceDate":"2018-07-03"},{"SOURCE_ROW_NUMBER":"659646","EVENT_NO":"4468882","INSPECTION_BEGIN_DT":"05/30/2018","INSPECTION_END_DT":"06/04/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16.5","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2018-05-30"},{"SOURCE_ROW_NUMBER":"154394","EVENT_NO":"6431649","INSPECTION_BEGIN_DT":"04/03/2018","INSPECTION_END_DT":"05/21/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"215.5","SUM_TOTAL_ON_SITE_HOURS":"151.5","sourceDate":"2018-04-03"},{"SOURCE_ROW_NUMBER":"659050","EVENT_NO":"4455526","INSPECTION_BEGIN_DT":"03/21/2018","INSPECTION_END_DT":"04/04/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13.25","SUM_TOTAL_ON_SITE_HOURS":"9.25","sourceDate":"2018-03-21"},{"SOURCE_ROW_NUMBER":"445657","EVENT_NO":"4455226","INSPECTION_BEGIN_DT":"03/15/2018","INSPECTION_END_DT":"03/27/2018","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2018-03-15"},{"SOURCE_ROW_NUMBER":"846887","EVENT_NO":"4455524","INSPECTION_BEGIN_DT":"01/02/2018","INSPECTION_END_DT":"03/08/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"253","SUM_TOTAL_ON_SITE_HOURS":"159","sourceDate":"2018-01-02"},{"SOURCE_ROW_NUMBER":"881545","EVENT_NO":"4468878","INSPECTION_BEGIN_DT":"12/14/2017","INSPECTION_END_DT":"12/20/2017","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2017-12-14"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014":{"hours":225,"employees":8,"production":709},"2015":{"hours":60078,"employees":24,"production":213279},"2016":{"hours":44166,"employees":19,"production":156198},"2017":{"hours":60716,"employees":23,"production":218343},"2018":{"hours":62270,"employees":24,"production":199265}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":87,"firstDate":"2015-02-10","lastDate":"2018-10-03","metrics":{"recentRows":0,"doseOver100":12,"actDoseTotal":4464,"pelDoseTotal":3072},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"112824","EVENT_NO":"4454414","SURVEY_DATE":"10/03/2018","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"36","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2018-10-03"},{"SOURCE_ROW_NUMBER":"112823","EVENT_NO":"4454414","SURVEY_DATE":"10/03/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"43","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2018-10-03"},{"SOURCE_ROW_NUMBER":"112822","EVENT_NO":"4454414","SURVEY_DATE":"10/03/2018","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"54","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2018-10-03"},{"SOURCE_ROW_NUMBER":"112821","EVENT_NO":"4454414","SURVEY_DATE":"10/03/2018","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"32","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2018-10-03"},{"SOURCE_ROW_NUMBER":"112820","EVENT_NO":"4454414","SURVEY_DATE":"10/03/2018","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"32","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2018-10-03"},{"SOURCE_ROW_NUMBER":"112844","EVENT_NO":"4456877","SURVEY_DATE":"08/29/2018","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"56","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"112843","EVENT_NO":"4456877","SURVEY_DATE":"08/29/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"63","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"112842","EVENT_NO":"4456877","SURVEY_DATE":"08/29/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"70","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"112841","EVENT_NO":"4456877","SURVEY_DATE":"08/29/2018","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"24","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"112840","EVENT_NO":"4456877","SURVEY_DATE":"08/29/2018","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"72","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"112901","EVENT_NO":"6431649","SURVEY_DATE":"04/06/2018","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"067","ACT_DOSE_85":"49","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2018-04-06"},{"SOURCE_ROW_NUMBER":"112900","EVENT_NO":"6431649","SURVEY_DATE":"04/06/2018","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"37","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2018-04-06"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":39,"firstDate":"2015-02-10","lastDate":"2018-10-03","metrics":{"recentRows":0,"voidSamples":5,"maxQuartzPct":8.7,"validSamples":34,"quartzPctTotal":182.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"48345","CASSETTE_NO":"58290394","SAMPLE_DT":"10/03/2018","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-10-03"},{"SOURCE_ROW_NUMBER":"111375","CASSETTE_NO":"58334925","SAMPLE_DT":"08/29/2018","QUARTZ_PCT":"03.0","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"28856","CASSETTE_NO":"58335293","SAMPLE_DT":"08/29/2018","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"167295","CASSETTE_NO":"58320553","SAMPLE_DT":"04/06/2018","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"21","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-04-06"},{"SOURCE_ROW_NUMBER":"91696","CASSETTE_NO":"58320551","SAMPLE_DT":"04/06/2018","QUARTZ_PCT":"04.4","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-04-06"},{"SOURCE_ROW_NUMBER":"40502","CASSETTE_NO":"58320548","SAMPLE_DT":"04/06/2018","QUARTZ_PCT":"06.0","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-04-06"},{"SOURCE_ROW_NUMBER":"151813","CASSETTE_NO":"58320606","SAMPLE_DT":"01/04/2018","QUARTZ_PCT":"03.7","QUARTZ_MICROGRAMS":"18","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-01-04"},{"SOURCE_ROW_NUMBER":"74524","CASSETTE_NO":"58320605","SAMPLE_DT":"01/04/2018","QUARTZ_PCT":"02.9","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-01-04"},{"SOURCE_ROW_NUMBER":"120880","CASSETTE_NO":"58311434","SAMPLE_DT":"10/06/2017","QUARTZ_PCT":"06.1","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-06"},{"SOURCE_ROW_NUMBER":"118468","CASSETTE_NO":"58311452","SAMPLE_DT":"10/06/2017","QUARTZ_PCT":"04.0","QUARTZ_MICROGRAMS":"34","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-06"},{"SOURCE_ROW_NUMBER":"87469","CASSETTE_NO":"58311429","SAMPLE_DT":"10/06/2017","QUARTZ_PCT":"04.1","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-06"},{"SOURCE_ROW_NUMBER":"16197","CASSETTE_NO":"58311504","SAMPLE_DT":"10/06/2017","QUARTZ_PCT":"05.1","QUARTZ_MICROGRAMS":"20","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-10-06"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":254,"firstDate":"2015-01-13","lastDate":"2018-12-03","metrics":{"ss":62,"amountDue":49356,"contested":0,"amountPaid":49356,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":50973},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1196876","VIOLATION_NO":"9136624","VIOLATION_ISSUE_DT":"12/03/2018","SIG_SUB":"Y","PART_SECTION":"75.380(d)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2018","PROPOSED_PENALTY":"405","AMOUNT_DUE":"405","AMOUNT_PAID":"405","CONTESTED_IND":"N","sourceDate":"2018-12-03"},{"SOURCE_ROW_NUMBER":"1196875","VIOLATION_NO":"9136623","VIOLATION_ISSUE_DT":"11/28/2018","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-11-28"},{"SOURCE_ROW_NUMBER":"1196874","VIOLATION_NO":"9136622","VIOLATION_ISSUE_DT":"11/15/2018","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-11-15"},{"SOURCE_ROW_NUMBER":"1196873","VIOLATION_NO":"9136621","VIOLATION_ISSUE_DT":"11/15/2018","SIG_SUB":"N","PART_SECTION":"77.500","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-11-15"},{"SOURCE_ROW_NUMBER":"1196872","VIOLATION_NO":"9136620","VIOLATION_ISSUE_DT":"11/07/2018","SIG_SUB":"Y","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/07/2018","PROPOSED_PENALTY":"395","AMOUNT_DUE":"395","AMOUNT_PAID":"395","CONTESTED_IND":"N","sourceDate":"2018-11-07"},{"SOURCE_ROW_NUMBER":"1196871","VIOLATION_NO":"9136619","VIOLATION_ISSUE_DT":"11/05/2018","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/07/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-11-05"},{"SOURCE_ROW_NUMBER":"1196870","VIOLATION_NO":"9136611","VIOLATION_ISSUE_DT":"10/10/2018","SIG_SUB":"N","PART_SECTION":"75.1722(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/10/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-10-10"},{"SOURCE_ROW_NUMBER":"1196869","VIOLATION_NO":"9136610","VIOLATION_ISSUE_DT":"10/04/2018","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/04/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-10-04"},{"SOURCE_ROW_NUMBER":"1196868","VIOLATION_NO":"9136609","VIOLATION_ISSUE_DT":"10/04/2018","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/04/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-10-04"},{"SOURCE_ROW_NUMBER":"1196859","VIOLATION_NO":"9136520","VIOLATION_ISSUE_DT":"09/26/2018","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"10/02/2018","CONTESTED_IND":"N","sourceDate":"2018-09-26"},{"SOURCE_ROW_NUMBER":"1196816","VIOLATION_NO":"9136511","VIOLATION_ISSUE_DT":"08/13/2018","SIG_SUB":"N","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/14/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-08-13"},{"SOURCE_ROW_NUMBER":"1196815","VIOLATION_NO":"9136510","VIOLATION_ISSUE_DT":"08/08/2018","SIG_SUB":"Y","PART_SECTION":"75.211(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/08/2018","PROPOSED_PENALTY":"395","AMOUNT_DUE":"395","AMOUNT_PAID":"395","CONTESTED_IND":"N","sourceDate":"2018-08-08"}]}],"safety":{"href":"/api/v1/mines/1519768/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519768/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","heading":"Electric power circuits and electric equipment; deenergization.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.500","part":"77","subchapter":"O","subpart":"F","id":"77.500","citation":"30 CFR 77.500","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","heading":"Roof testing and scaling.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.211","part":"75","subchapter":"O","subpart":"C","id":"75.211","citation":"30 CFR 75.211","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519768","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}