{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519749","name":"Riveredge Surface Operation","status":"Abandoned","status_date":"2019-11-04","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Mclean","nearest_town":"Beech Grove","operator_id":"0136993","operator_name":"Rough Creek Mining, LLC","controller_id":"C15455","controller_name":"Alliance Resource Partners LP","district":"C10","office":"Madisonville KY Field Office","employees":0,"latitude":37.6575,"longitude":-87.414167},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":900},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519749","name":"Riveredge Surface Operation"},"operator":{"type":"operator","id":"0136993","name":"Rough Creek Mining, LLC"},"controller":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"mine","id":"1519749","name":"Riveredge Surface Operation"},"validFrom":"2012-05-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519749|0098293|2012-05-02|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0122770","name":"Pennyrile Energy, LLC"},"object":{"type":"mine","id":"1519749","name":"Riveredge Surface Operation"},"validFrom":"2014-06-10","validTo":"2020-04-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519749|0122770|2014-06-10|2020-04-12"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"operator","id":"0122770","name":"Pennyrile Energy, LLC"},"validFrom":"2014-06-10","validTo":"2020-04-12","current":false,"derived":true,"evidenceMineId":"1519749","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519749|0122770|2014-06-10|0098293|2012-05-02|16167"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"1519749","name":"Riveredge Surface Operation"},"validFrom":"2015-02-03","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519749|C15455|2015-02-03|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0136993","name":"Rough Creek Mining, LLC"},"object":{"type":"mine","id":"1519749","name":"Riveredge Surface Operation"},"validFrom":"2020-04-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519749|0136993|2020-04-13|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"0136993","name":"Rough Creek Mining, LLC"},"validFrom":"2020-04-13","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519749","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519749|0136993|2020-04-13|C15455|2015-02-03|95685"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":8,"firstDate":"2015-02-06","lastDate":"2018-07-22","metrics":{"daysLost":386,"injuries":8,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"225242","DOCUMENT_NO":"220182110046","ACCIDENT_DT":"07/22/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"64","NARRATIVE":"Employee patching hole on refuge chute attempting to hold large steel patch on chute and strained shoulder and right arm.","sourceDate":"2018-07-22"},{"SOURCE_ROW_NUMBER":"108879","DOCUMENT_NO":"220181730012","ACCIDENT_DT":"06/14/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"EXPLODING VESSELS UNDER PRESSURE","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"While spraying out a heavy medum sump a 1 inch conduit being used to direct water jumped up from pressure striking employee in the left side of the temple area. Employee received a fracture to the cheek area.","sourceDate":"2018-06-14"},{"SOURCE_ROW_NUMBER":"259798","DOCUMENT_NO":"220171800037","ACCIDENT_DT":"06/26/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Employee states while working on clean coal vibrator, after finishing, back allegedly started tightening up.","sourceDate":"2017-06-26"},{"SOURCE_ROW_NUMBER":"242595","DOCUMENT_NO":"220162230009","ACCIDENT_DT":"08/08/2016","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Miner, Prospector, NEC","NO_INJURIES":"1","DAYS_LOST":"175","NARRATIVE":"Injured was off the clock and traveling to work on the haul/travel road on mine property. Approximately 1 mile from St Rt 593, injured lost control of the personal vehicle and hit rock wall along travel road. Injured suffered a concussion and contusions.","sourceDate":"2016-08-08"},{"SOURCE_ROW_NUMBER":"79028","DOCUMENT_NO":"220153360013","ACCIDENT_DT":"11/23/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"43","NARRATIVE":"Injured was climbing onto a Komatsu HM350 gob truck to enter the operator's deck area. His left foot slipped and he fell. He suffered a contusion to his left knee.","sourceDate":"2015-11-23"},{"SOURCE_ROW_NUMBER":"221000","DOCUMENT_NO":"220153240032","ACCIDENT_DT":"11/16/2015","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured was dumping a bag of dry cat into the cat feeder. He felt a pain in his lower back.","sourceDate":"2015-11-16"},{"SOURCE_ROW_NUMBER":"255433","DOCUMENT_NO":"220151880017","ACCIDENT_DT":"06/11/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer","NO_INJURIES":"1","DAYS_LOST":"3","NARRATIVE":"Injured slid off the hood of a Komatsu dozer after changing a headlight. He stated he may have pinched his right testicle. He was unsure of how he received the injury and stated he must have received it during this event. Accident report was filled out on 6/13/2015. After medical inquiry it was deemed to be a reportable event.","sourceDate":"2015-06-11"},{"SOURCE_ROW_NUMBER":"190762","DOCUMENT_NO":"220151530036","ACCIDENT_DT":"02/06/2015","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Warehouseman, Bagger, Palletizer/Stacker, Store keeper, Packager, Fabricator, Cleaning plant operator","NO_INJURIES":"1","DAYS_LOST":"90","NARRATIVE":"The injured was taking apart a water line fitting with 2 pipe wrenches on 2/06/2015. He felt a pain in his shoulder. He reported accident on 2/10/2015. He had not missed work and continued to do his normal job but required surgery on his right shoulder on 5/29/2015. He has not been released to come back to work since surgery on 5/29/2015.","sourceDate":"2015-02-06"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2019-11-04","lastDate":"2019-11-04","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":110,"firstDate":"2014-09-03","lastDate":"2019-10-30","metrics":{"ss":36,"delinquent":93,"recentRows":0,"paidPenalty":19914,"proposedPenalty":21133,"currentAssessment":19914},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2041781","VIOLATION_NO":"9147267","ISSUE_DT":"10/30/2019","CFR_STANDARD_CD":"71.209(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"230.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-30"},{"SOURCE_ROW_NUMBER":"2041780","VIOLATION_NO":"9147266","ISSUE_DT":"10/29/2019","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"2041779","VIOLATION_NO":"9147265","ISSUE_DT":"10/29/2019","CFR_STANDARD_CD":"77.410(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"514.00","CURRENT_ASSESSMENT_AMT":"135.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"2041778","VIOLATION_NO":"9147264","ISSUE_DT":"10/29/2019","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"2041777","VIOLATION_NO":"9147263","ISSUE_DT":"10/29/2019","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1146.00","CURRENT_ASSESSMENT_AMT":"572.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"2041546","VIOLATION_NO":"9147007","ISSUE_DT":"07/17/2019","CFR_STANDARD_CD":"77.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"2041545","VIOLATION_NO":"9147006","ISSUE_DT":"07/17/2019","CFR_STANDARD_CD":"77.403-1(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"2041544","VIOLATION_NO":"9147004","ISSUE_DT":"06/24/2019","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-06-24"},{"SOURCE_ROW_NUMBER":"2041543","VIOLATION_NO":"9144787","ISSUE_DT":"05/22/2019","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-05-22"},{"SOURCE_ROW_NUMBER":"2041542","VIOLATION_NO":"9144786","ISSUE_DT":"05/22/2019","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-05-22"},{"SOURCE_ROW_NUMBER":"2041541","VIOLATION_NO":"9144776","ISSUE_DT":"05/08/2019","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-05-08"},{"SOURCE_ROW_NUMBER":"2041540","VIOLATION_NO":"4273809","ISSUE_DT":"04/16/2019","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-04-16"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":11,"firstDate":"2016-07-12","lastDate":"2020-04-03","metrics":{"appeals":0,"decisions":11,"recentRows":0,"decisionPenalty":2354,"originalPenalty":3573},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"418689","VIOLATION_NO":"9147264","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-04-03"},{"SOURCE_ROW_NUMBER":"418688","VIOLATION_NO":"9147263","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1146.00","DECISION_PENALTY_AMT":"572.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-04-03"},{"SOURCE_ROW_NUMBER":"417829","VIOLATION_NO":"9147266","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-04-03"},{"SOURCE_ROW_NUMBER":"142823","VIOLATION_NO":"9147267","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"135.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-04-03"},{"SOURCE_ROW_NUMBER":"142822","VIOLATION_NO":"9147265","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"514.00","DECISION_PENALTY_AMT":"135.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-04-03"},{"SOURCE_ROW_NUMBER":"389433","VIOLATION_NO":"9049378","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-24"},{"SOURCE_ROW_NUMBER":"389337","VIOLATION_NO":"9049375","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-24"},{"SOURCE_ROW_NUMBER":"388895","VIOLATION_NO":"9049379","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-24"},{"SOURCE_ROW_NUMBER":"125342","VIOLATION_NO":"9049376","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"351.00","DECISION_PENALTY_AMT":"351.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-24"},{"SOURCE_ROW_NUMBER":"124791","VIOLATION_NO":"9049380","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2017-07-24"},{"SOURCE_ROW_NUMBER":"119520","VIOLATION_NO":"9048011","DOCKET_NO":"KENT 2016-0200","DECISION_DT":"07/12/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"463.00","JUDGE_FIRST_NAME":"William","JUDGE_LAST_NAME":"Moran","sourceDate":"2016-07-12"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":126,"firstDate":"2014-09-22","lastDate":"2019-09-09","metrics":{"recentRows":0,"cpdmSamples":30,"voidSamples":16,"validSamples":110,"maxConcentration":3.042,"concentrationTotal":22.99},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1953146","SMP_TAKEN_DT":"9/9/2019","CONC":".021","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-09"},{"SOURCE_ROW_NUMBER":"2976236","SMP_TAKEN_DT":"9/6/2019","CONC":".119","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DWP NOT IN PRODUCING STATUS","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-06"},{"SOURCE_ROW_NUMBER":"2890091","SMP_TAKEN_DT":"9/6/2019","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-09-06"},{"SOURCE_ROW_NUMBER":"828587","CASS_NUM":"58340552","SMP_TAKEN_DT":"7/17/2019","CONC":".094","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"784538","CASS_NUM":"58340621","SMP_TAKEN_DT":"7/17/2019","CONC":".042","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"697875","CASS_NUM":"58340585","SMP_TAKEN_DT":"7/17/2019","CONC":".193","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"563677","CASS_NUM":"58340517","SMP_TAKEN_DT":"7/17/2019","CONC":".017","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"340389","CASS_NUM":"58340566","SMP_TAKEN_DT":"7/17/2019","CONC":".101","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"2290336","SMP_TAKEN_DT":"4/30/2019","CONC":".031","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-04-30"},{"SOURCE_ROW_NUMBER":"2459288","SMP_TAKEN_DT":"3/30/2019","CONC":".064","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-03-30"},{"SOURCE_ROW_NUMBER":"2458422","SMP_TAKEN_DT":"3/28/2019","CONC":".154","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-03-28"},{"SOURCE_ROW_NUMBER":"2884848","SMP_TAKEN_DT":"2/18/2019","CONC":".061","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-02-18"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":7,"firstDate":"2015-02-23","lastDate":"2019-06-17","metrics":{"linkedIssuances":7},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":11,"firstDate":"2015-11-19","lastDate":"2019-10-30","metrics":{"decisions":11,"ssChanged":6,"recentRows":0,"decisionPenalty":2354,"proposedPenalty":3573},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"162541","CITATION_NO":"9147267","CITATION_ISSUE_DT":"10/30/2019","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","CFR_STANDARD_CODE":"71.209(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"135.00","sourceDate":"2019-10-30"},{"SOURCE_ROW_NUMBER":"275754","CITATION_NO":"9147266","CITATION_ISSUE_DT":"10/29/2019","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"103143","CITATION_NO":"9147265","CITATION_ISSUE_DT":"10/29/2019","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","CFR_STANDARD_CODE":"77.410(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"514.00","DECISION_PENALTY_AMT":"135.00","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"103142","CITATION_NO":"9147263","CITATION_ISSUE_DT":"10/29/2019","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","CFR_STANDARD_CODE":"77.502-2","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1146.00","DECISION_PENALTY_AMT":"572.00","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"47678","CITATION_NO":"9147264","CITATION_ISSUE_DT":"10/29/2019","DOCKET_NO":"KENT 2020-0041","DECISION_DT":"04/03/2020","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"438991","CITATION_NO":"9049379","CITATION_ISSUE_DT":"10/25/2016","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","CFR_STANDARD_CODE":"77.1110","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","sourceDate":"2016-10-25"},{"SOURCE_ROW_NUMBER":"95028","CITATION_NO":"9049380","CITATION_ISSUE_DT":"10/25/2016","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","CFR_STANDARD_CODE":"77.502","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","sourceDate":"2016-10-25"},{"SOURCE_ROW_NUMBER":"326217","CITATION_NO":"9049375","CITATION_ISSUE_DT":"10/18/2016","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","sourceDate":"2016-10-18"},{"SOURCE_ROW_NUMBER":"212182","CITATION_NO":"9049376","CITATION_ISSUE_DT":"10/18/2016","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","CFR_STANDARD_CODE":"77.512","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"351.00","DECISION_PENALTY_AMT":"351.00","sourceDate":"2016-10-18"},{"SOURCE_ROW_NUMBER":"95027","CITATION_NO":"9049378","CITATION_ISSUE_DT":"10/18/2016","DOCKET_NO":"KENT 2017-0104","DECISION_DT":"07/24/2017","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"114.00","DECISION_PENALTY_AMT":"114.00","sourceDate":"2016-10-18"},{"SOURCE_ROW_NUMBER":"40304","CITATION_NO":"9048011","CITATION_ISSUE_DT":"11/19/2015","DOCKET_NO":"KENT 2016-0200","DECISION_DT":"07/12/2016","CFR_STANDARD_CODE":"77.400(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"463.00","sourceDate":"2015-11-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":352,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":55,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2014-06-10","lastDate":"2020-04-13","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":24,"firstDate":"2014-09-03","lastDate":"2019-10-01","metrics":{"inspectors":77,"recentRows":0,"onSiteHours":945.5,"inspectionHours":1426.25,"inspectionSamples":105},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"240625","EVENT_NO":"6485513","INSPECTION_BEGIN_DT":"10/01/2019","INSPECTION_END_DT":"12/05/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"53.5","SUM_TOTAL_ON_SITE_HOURS":"33","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"531758","EVENT_NO":"6484429","INSPECTION_BEGIN_DT":"09/10/2019","INSPECTION_END_DT":"09/10/2019","ACTIVITY_CODE":"E23","ACTIVITY":"Impoundment Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2019-09-10"},{"SOURCE_ROW_NUMBER":"384940","EVENT_NO":"6485472","INSPECTION_BEGIN_DT":"03/31/2019","INSPECTION_END_DT":"07/22/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"103.5","SUM_TOTAL_ON_SITE_HOURS":"70.5","sourceDate":"2019-03-31"},{"SOURCE_ROW_NUMBER":"146371","EVENT_NO":"4490798","INSPECTION_BEGIN_DT":"10/16/2018","INSPECTION_END_DT":"03/27/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"128","SUM_TOTAL_ON_SITE_HOURS":"87","sourceDate":"2018-10-16"},{"SOURCE_ROW_NUMBER":"312427","EVENT_NO":"6484723","INSPECTION_BEGIN_DT":"08/20/2018","INSPECTION_END_DT":"08/20/2018","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2018-08-20"},{"SOURCE_ROW_NUMBER":"785278","EVENT_NO":"6484325","INSPECTION_BEGIN_DT":"04/01/2018","INSPECTION_END_DT":"09/06/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"141","SUM_TOTAL_ON_SITE_HOURS":"93.5","sourceDate":"2018-04-01"},{"SOURCE_ROW_NUMBER":"1090571","EVENT_NO":"4490579","INSPECTION_BEGIN_DT":"10/16/2017","INSPECTION_END_DT":"10/18/2017","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2017-10-16"},{"SOURCE_ROW_NUMBER":"1004368","EVENT_NO":"4489709","INSPECTION_BEGIN_DT":"10/02/2017","INSPECTION_END_DT":"03/28/2018","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"95.5","SUM_TOTAL_ON_SITE_HOURS":"61.75","sourceDate":"2017-10-02"},{"SOURCE_ROW_NUMBER":"1006342","EVENT_NO":"6484094","INSPECTION_BEGIN_DT":"04/07/2017","INSPECTION_END_DT":"09/20/2017","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"8","SUM_TOTAL_INSP_HOURS":"136.5","SUM_TOTAL_ON_SITE_HOURS":"95.25","sourceDate":"2017-04-07"},{"SOURCE_ROW_NUMBER":"694320","EVENT_NO":"6484013","INSPECTION_BEGIN_DT":"03/02/2017","INSPECTION_END_DT":"03/30/2017","ACTIVITY_CODE":"E17","ACTIVITY":"Special Emphasis Programs","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"29.25","SUM_TOTAL_ON_SITE_HOURS":"19.25","sourceDate":"2017-03-02"},{"SOURCE_ROW_NUMBER":"620444","EVENT_NO":"6484088","INSPECTION_BEGIN_DT":"12/26/2016","INSPECTION_END_DT":"01/30/2017","ACTIVITY_CODE":"E33","ACTIVITY":"Non-Chargeable Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2016-12-26"},{"SOURCE_ROW_NUMBER":"291541","EVENT_NO":"4488094","INSPECTION_BEGIN_DT":"12/12/2016","INSPECTION_END_DT":"12/12/2016","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"21","SUM_TOTAL_ON_SITE_HOURS":"15.5","sourceDate":"2016-12-12"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2019-Q4":{"hours":3417,"employees":18,"production":0},"2019-Q3":{"hours":15174,"employees":21,"production":0},"2019-Q2":{"hours":17126,"employees":28,"production":0},"2019-Q1":{"hours":17313,"employees":30,"production":0},"2018-Q4":{"hours":16416,"employees":30,"production":0},"2018-Q3":{"hours":16614,"employees":30,"production":0},"2018-Q2":{"hours":17218,"employees":25,"production":0},"2018-Q1":{"hours":16245,"employees":30,"production":0},"2017-Q4":{"hours":16924,"employees":30,"production":0},"2017-Q3":{"hours":1491,"employees":24,"production":0},"2017-Q2":{"hours":18757,"employees":33,"production":0},"2017-Q1":{"hours":20158,"employees":32,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014":{"hours":23203,"employees":22,"production":0},"2015":{"hours":63049,"employees":25,"production":0},"2016":{"hours":78768,"employees":35,"production":0},"2017":{"hours":57330,"employees":30,"production":0},"2018":{"hours":66493,"employees":29,"production":0},"2019":{"hours":53030,"employees":24,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":36,"firstDate":"2014-09-22","lastDate":"2018-12-04","metrics":{"recentRows":0,"doseOver100":8,"actDoseTotal":2054,"pelDoseTotal":1313},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"112587","EVENT_NO":"4490798","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"105","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"112586","EVENT_NO":"4490798","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"ROAD GRADER OPERATOR","MACHINE_CD":"28","MANUFACTURER_CD":"018","ACT_DOSE_85":"34","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"112585","EVENT_NO":"4490798","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"10","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"112584","EVENT_NO":"4490798","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"118","PEL_DOSE_90":"94","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"112583","EVENT_NO":"4490798","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"51","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"112592","EVENT_NO":"6484325","SURVEY_DATE":"06/05/2018","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2018-06-05"},{"SOURCE_ROW_NUMBER":"112591","EVENT_NO":"6484325","SURVEY_DATE":"06/05/2018","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"40","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2018-06-05"},{"SOURCE_ROW_NUMBER":"112590","EVENT_NO":"6484325","SURVEY_DATE":"06/05/2018","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2018-06-05"},{"SOURCE_ROW_NUMBER":"112589","EVENT_NO":"6484325","SURVEY_DATE":"06/05/2018","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"37","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2018-06-05"},{"SOURCE_ROW_NUMBER":"112588","EVENT_NO":"6484325","SURVEY_DATE":"06/05/2018","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"27","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2018-06-05"},{"SOURCE_ROW_NUMBER":"112582","EVENT_NO":"4490500","SURVEY_DATE":"11/22/2016","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"39","MANUFACTURER_CD":"020","ACT_DOSE_85":"4","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2016-11-22"},{"SOURCE_ROW_NUMBER":"112581","EVENT_NO":"4490500","SURVEY_DATE":"11/22/2016","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"93","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2016-11-22"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":13,"firstDate":"2014-09-22","lastDate":"2019-07-17","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":3.4,"validSamples":13,"quartzPctTotal":22.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"133870","CASSETTE_NO":"58340585","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"01.0","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"127634","CASSETTE_NO":"58310820","SAMPLE_DT":"07/23/2018","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-07-23"},{"SOURCE_ROW_NUMBER":"147696","CASSETTE_NO":"58280548","SAMPLE_DT":"11/29/2017","QUARTZ_PCT":"03.4","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-11-29"},{"SOURCE_ROW_NUMBER":"137737","CASSETTE_NO":"58280544","SAMPLE_DT":"11/29/2017","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-11-29"},{"SOURCE_ROW_NUMBER":"107432","CASSETTE_NO":"58239827","SAMPLE_DT":"11/22/2016","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-11-22"},{"SOURCE_ROW_NUMBER":"28534","CASSETTE_NO":"58239527","SAMPLE_DT":"11/22/2016","QUARTZ_PCT":"01.1","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-11-22"},{"SOURCE_ROW_NUMBER":"130731","CASSETTE_NO":"58239905","SAMPLE_DT":"04/19/2016","QUARTZ_PCT":"01.4","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-04-19"},{"SOURCE_ROW_NUMBER":"158235","CASSETTE_NO":"58230686","SAMPLE_DT":"01/25/2016","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-01-25"},{"SOURCE_ROW_NUMBER":"159178","CASSETTE_NO":"58208123","SAMPLE_DT":"06/23/2015","QUARTZ_PCT":"01.1","QUARTZ_MICROGRAMS":"1","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-06-23"},{"SOURCE_ROW_NUMBER":"149193","CASSETTE_NO":"58208012","SAMPLE_DT":"02/24/2015","QUARTZ_PCT":"02.7","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-02-24"},{"SOURCE_ROW_NUMBER":"88241","CASSETTE_NO":"58208020","SAMPLE_DT":"02/24/2015","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-02-24"},{"SOURCE_ROW_NUMBER":"142963","CASSETTE_NO":"58192718","SAMPLE_DT":"09/22/2014","QUARTZ_PCT":"01.5","QUARTZ_MICROGRAMS":"5","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-09-22"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":114,"firstDate":"2014-09-03","lastDate":"2019-10-30","metrics":{"ss":36,"amountDue":19914,"contested":0,"amountPaid":19914,"recentRows":0,"section104d":0,"unterminated":2,"proposedPenalty":21133},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1195829","VIOLATION_NO":"9147267","VIOLATION_ISSUE_DT":"10/30/2019","SIG_SUB":"N","PART_SECTION":"71.209(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/10/2019","PROPOSED_PENALTY":"230","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2019-10-30"},{"SOURCE_ROW_NUMBER":"1195828","VIOLATION_NO":"9147266","VIOLATION_ISSUE_DT":"10/29/2019","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"1195827","VIOLATION_NO":"9147265","VIOLATION_ISSUE_DT":"10/29/2019","SIG_SUB":"N","PART_SECTION":"77.410(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2019","PROPOSED_PENALTY":"514","AMOUNT_DUE":"135","AMOUNT_PAID":"135","CONTESTED_IND":"N","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"1195826","VIOLATION_NO":"9147264","VIOLATION_ISSUE_DT":"10/29/2019","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"1195825","VIOLATION_NO":"9147263","VIOLATION_ISSUE_DT":"10/29/2019","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/29/2019","PROPOSED_PENALTY":"1146","AMOUNT_DUE":"572","AMOUNT_PAID":"572","CONTESTED_IND":"N","sourceDate":"2019-10-29"},{"SOURCE_ROW_NUMBER":"1195778","VIOLATION_NO":"9147007","VIOLATION_ISSUE_DT":"07/17/2019","SIG_SUB":"N","PART_SECTION":"77.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/17/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"1195777","VIOLATION_NO":"9147006","VIOLATION_ISSUE_DT":"07/17/2019","SIG_SUB":"N","PART_SECTION":"77.403-1(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/17/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"1195776","VIOLATION_NO":"9147004","VIOLATION_ISSUE_DT":"06/24/2019","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/24/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-06-24"},{"SOURCE_ROW_NUMBER":"1195775","VIOLATION_NO":"9144787","VIOLATION_ISSUE_DT":"05/22/2019","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/22/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-05-22"},{"SOURCE_ROW_NUMBER":"1195774","VIOLATION_NO":"9144786","VIOLATION_ISSUE_DT":"05/22/2019","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/22/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-05-22"},{"SOURCE_ROW_NUMBER":"1195773","VIOLATION_NO":"9144776","VIOLATION_ISSUE_DT":"05/08/2019","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/08/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-05-08"},{"SOURCE_ROW_NUMBER":"1195772","VIOLATION_NO":"4273809","VIOLATION_ISSUE_DT":"04/16/2019","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/16/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-04-16"}]}],"safety":{"href":"/api/v1/mines/1519749/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519749/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Status change reports.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-71/subpart-C/section-71.209","part":"71","subchapter":"O","subpart":"C","id":"71.209","citation":"30 CFR 71.209","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 71—MANDATORY HEALTH STANDARDS—SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":4},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Identification of circuit breakers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.904","part":"77","subchapter":"O","subpart":"J","id":"77.904","citation":"30 CFR 77.904","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Mobile equipment; rollover protective structures (ROPS).","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.403-1","part":"77","subchapter":"O","subpart":"E","id":"77.403-1","citation":"30 CFR 77.403-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519749","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}