{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519712","name":"Cheyenne Enterprises 9E","status":"Abandoned and Sealed","status_date":"2025-05-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Pikeville","operator_id":"0060024","operator_name":"Cheyenne Enterprises Inc.","controller_id":"0142565","controller_name":"Greg  Damron","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.499167,"longitude":-82.568889},"coverage":{"contributingSources":14,"registeredSources":20,"sourceRows":548},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519712","name":"Cheyenne Enterprises 9E"},"operator":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc."},"controller":{"type":"controller","id":"0142565","name":"Greg  Damron"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0050011","name":"Greg  Damron  et al"},"object":{"type":"mine","id":"1519712","name":"Cheyenne Enterprises 9E"},"validFrom":"2005-05-26","validTo":"2018-08-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0050011|2005-05-26|2018-08-12"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0096493","name":"Jerry  Bevins"},"object":{"type":"mine","id":"1519712","name":"Cheyenne Enterprises 9E"},"validFrom":"2012-09-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0096493|2012-09-04|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0124751","name":"Dynasty Mining Inc"},"object":{"type":"mine","id":"1519712","name":"Cheyenne Enterprises 9E"},"validFrom":"2013-07-26","validTo":"2018-08-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0124751|2013-07-26|2018-08-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0096493","name":"Jerry  Bevins"},"object":{"type":"operator","id":"0124751","name":"Dynasty Mining Inc"},"validFrom":"2013-07-26","validTo":"2018-08-13","current":false,"derived":true,"evidenceMineId":"1519712","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0124751|2013-07-26|0096493|2012-09-04|15852"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0142565","name":"Greg  Damron"},"object":{"type":"mine","id":"1519712","name":"Cheyenne Enterprises 9E"},"validFrom":"2018-08-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0142565|2018-08-13|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc."},"object":{"type":"mine","id":"1519712","name":"Cheyenne Enterprises 9E"},"validFrom":"2018-08-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0060024|2018-08-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0050011","name":"Greg  Damron  et al"},"object":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc."},"validFrom":"2018-08-14","validTo":"2018-08-12","current":false,"derived":true,"evidenceMineId":"1519712","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0060024|2018-08-14|0050011|2005-05-26|6263"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0050011","name":"Henry  Chaney  et al"},"object":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc."},"validFrom":"2018-08-14","validTo":"2018-08-12","current":false,"derived":true,"evidenceMineId":"1519712","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0060024|2018-08-14|0050011|2005-05-26|6264"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0142565","name":"Greg  Damron"},"object":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc."},"validFrom":"2018-08-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519712","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519712|0060024|2018-08-14|0142565|2018-08-13|28914"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2025-05-30","lastDate":"2025-05-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":86,"firstDate":"2013-07-24","lastDate":"2019-02-12","metrics":{"ss":16,"delinquent":86,"recentRows":0,"paidPenalty":10021,"proposedPenalty":10021,"currentAssessment":10021},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1965118","VIOLATION_NO":"3787305","ISSUE_DT":"02/12/2019","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-02-12"},{"SOURCE_ROW_NUMBER":"1965119","VIOLATION_NO":"8309051","ISSUE_DT":"02/05/2019","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-02-05"},{"SOURCE_ROW_NUMBER":"1965117","VIOLATION_NO":"3786456","ISSUE_DT":"01/24/2019","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-01-24"},{"SOURCE_ROW_NUMBER":"1965116","VIOLATION_NO":"3786455","ISSUE_DT":"01/23/2019","CFR_STANDARD_CD":"75.1101-10","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-01-23"},{"SOURCE_ROW_NUMBER":"1965115","VIOLATION_NO":"2449532","ISSUE_DT":"01/16/2019","CFR_STANDARD_CD":"75.1714(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-01-16"},{"SOURCE_ROW_NUMBER":"1965114","VIOLATION_NO":"2449531","ISSUE_DT":"01/14/2019","CFR_STANDARD_CD":"75.1600-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-01-14"},{"SOURCE_ROW_NUMBER":"1966332","VIOLATION_NO":"4021518","ISSUE_DT":"12/26/2018","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"230.00","CURRENT_ASSESSMENT_AMT":"230.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-12-26"},{"SOURCE_ROW_NUMBER":"1966331","VIOLATION_NO":"4021516","ISSUE_DT":"12/19/2018","CFR_STANDARD_CD":"70.100(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-12-19"},{"SOURCE_ROW_NUMBER":"1962219","VIOLATION_NO":"9098398","ISSUE_DT":"12/10/2018","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-12-10"},{"SOURCE_ROW_NUMBER":"1962218","VIOLATION_NO":"9098397","ISSUE_DT":"12/06/2018","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-12-06"},{"SOURCE_ROW_NUMBER":"1962210","VIOLATION_NO":"4021514","ISSUE_DT":"12/04/2018","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"1962217","VIOLATION_NO":"8178988","ISSUE_DT":"11/30/2018","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"118.00","CURRENT_ASSESSMENT_AMT":"118.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2018-11-30"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":154,"firstDate":"2014-04-22","lastDate":"2019-05-07","metrics":{"recentRows":0,"cpdmSamples":76,"voidSamples":26,"validSamples":128,"maxConcentration":3.084,"concentrationTotal":63.435},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2120240","SMP_TAKEN_DT":"5/7/2019","CONC":".153","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-07"},{"SOURCE_ROW_NUMBER":"1778861","SMP_TAKEN_DT":"5/7/2019","CONC":".249","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-07"},{"SOURCE_ROW_NUMBER":"1778443","SMP_TAKEN_DT":"5/3/2019","CONC":".089","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-03"},{"SOURCE_ROW_NUMBER":"1693769","SMP_TAKEN_DT":"5/3/2019","CONC":".562","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-03"},{"SOURCE_ROW_NUMBER":"2801266","SMP_TAKEN_DT":"5/2/2019","CONC":".252","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-02"},{"SOURCE_ROW_NUMBER":"1693814","SMP_TAKEN_DT":"5/2/2019","CONC":".669","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-02"},{"SOURCE_ROW_NUMBER":"2290873","SMP_TAKEN_DT":"5/1/2019","CONC":".203","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-01"},{"SOURCE_ROW_NUMBER":"2120222","SMP_TAKEN_DT":"5/1/2019","CONC":".231","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-05-01"},{"SOURCE_ROW_NUMBER":"2290053","SMP_TAKEN_DT":"4/30/2019","CONC":".422","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-04-30"},{"SOURCE_ROW_NUMBER":"2119500","SMP_TAKEN_DT":"4/30/2019","CONC":".395","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-04-30"},{"SOURCE_ROW_NUMBER":"1948982","SMP_TAKEN_DT":"4/25/2019","CONC":".31","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-04-25"},{"SOURCE_ROW_NUMBER":"2715588","SMP_TAKEN_DT":"4/24/2019","CONC":".297","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-04-24"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2014-08-08","lastDate":"2014-10-07","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":65,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":15,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2013-07-26","lastDate":"2018-08-14","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":51,"firstDate":"2013-07-24","lastDate":"2025-05-30","metrics":{"inspectors":96,"recentRows":4,"onSiteHours":825.25,"inspectionHours":1345,"inspectionSamples":184},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"267853","EVENT_NO":"F0056E3","INSPECTION_BEGIN_DT":"05/30/2025","INSPECTION_END_DT":"05/30/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2025-05-30"},{"SOURCE_ROW_NUMBER":"11678","EVENT_NO":"F0056D9","INSPECTION_BEGIN_DT":"03/03/2025","INSPECTION_END_DT":"03/03/2025","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2025-03-03"},{"SOURCE_ROW_NUMBER":"1044929","EVENT_NO":"4132917","INSPECTION_BEGIN_DT":"11/18/2024","INSPECTION_END_DT":"11/18/2024","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2024-11-18"},{"SOURCE_ROW_NUMBER":"554446","EVENT_NO":"4414566","INSPECTION_BEGIN_DT":"09/13/2021","INSPECTION_END_DT":"09/13/2021","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2021-09-13"},{"SOURCE_ROW_NUMBER":"266813","EVENT_NO":"6398913","INSPECTION_BEGIN_DT":"04/02/2020","INSPECTION_END_DT":"04/02/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2020-04-02"},{"SOURCE_ROW_NUMBER":"153653","EVENT_NO":"4431761","INSPECTION_BEGIN_DT":"02/10/2020","INSPECTION_END_DT":"02/10/2020","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2020-02-10"},{"SOURCE_ROW_NUMBER":"325860","EVENT_NO":"6401620","INSPECTION_BEGIN_DT":"10/23/2019","INSPECTION_END_DT":"10/23/2019","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2019-10-23"},{"SOURCE_ROW_NUMBER":"411497","EVENT_NO":"6401613","INSPECTION_BEGIN_DT":"08/05/2019","INSPECTION_END_DT":"08/05/2019","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2019-08-05"},{"SOURCE_ROW_NUMBER":"1074614","EVENT_NO":"6401610","INSPECTION_BEGIN_DT":"04/01/2019","INSPECTION_END_DT":"05/23/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"41.5","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2019-04-01"},{"SOURCE_ROW_NUMBER":"937466","EVENT_NO":"4422106","INSPECTION_BEGIN_DT":"03/19/2019","INSPECTION_END_DT":"03/19/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"794086","EVENT_NO":"6401182","INSPECTION_BEGIN_DT":"01/10/2019","INSPECTION_END_DT":"03/06/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"186.75","SUM_TOTAL_ON_SITE_HOURS":"132.5","sourceDate":"2019-01-10"},{"SOURCE_ROW_NUMBER":"747400","EVENT_NO":"6401475","INSPECTION_BEGIN_DT":"12/19/2018","INSPECTION_END_DT":"01/29/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"46.5","SUM_TOTAL_ON_SITE_HOURS":"27.5","sourceDate":"2018-12-19"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":42,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2020-Q2":{"hours":0,"employees":0,"production":0},"2020-Q1":{"hours":330,"employees":1,"production":0},"2019-Q4":{"hours":790,"employees":2,"production":0},"2019-Q3":{"hours":1336,"employees":3,"production":0},"2019-Q2":{"hours":5218,"employees":13,"production":3801},"2019-Q1":{"hours":9085,"employees":13,"production":9393},"2018-Q4":{"hours":6578,"employees":11,"production":3425},"2018-Q3":{"hours":1298,"employees":7,"production":0},"2018-Q2":{"hours":0,"employees":0,"production":0},"2018-Q1":{"hours":0,"employees":0,"production":0},"2017-Q4":{"hours":0,"employees":0,"production":0},"2017-Q3":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013":{"hours":50,"employees":1,"production":0},"2014":{"hours":12518,"employees":7,"production":46200},"2015":{"hours":1742,"employees":9,"production":2083},"2018":{"hours":7876,"employees":10,"production":3425},"2019":{"hours":16429,"employees":14,"production":13194},"2020":{"hours":330,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":20,"firstDate":"2014-06-05","lastDate":"2019-03-05","metrics":{"recentRows":0,"doseOver100":4,"actDoseTotal":1127,"pelDoseTotal":882},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"111524","EVENT_NO":"6401182","SURVEY_DATE":"03/05/2019","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"26","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2019-03-05"},{"SOURCE_ROW_NUMBER":"111517","EVENT_NO":"6398144","SURVEY_DATE":"12/11/2018","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"12","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2018-12-11"},{"SOURCE_ROW_NUMBER":"111523","EVENT_NO":"6398144","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"23","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"111522","EVENT_NO":"6398144","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"83","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"111521","EVENT_NO":"6398144","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"24","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"111520","EVENT_NO":"6398144","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"37","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"111519","EVENT_NO":"6398144","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"73","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"111518","EVENT_NO":"6398144","SURVEY_DATE":"12/04/2018","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"73","PEL_DOSE_90":"61","SURVEY_TYPE":"I","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"111515","EVENT_NO":"6392736","SURVEY_DATE":"06/06/2014","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"7","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2014-06-06"},{"SOURCE_ROW_NUMBER":"111516","EVENT_NO":"6392736","SURVEY_DATE":"06/05/2014","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"17","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2014-06-05"},{"SOURCE_ROW_NUMBER":"111514","EVENT_NO":"6392736","SURVEY_DATE":"06/05/2014","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"102","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2014-06-05"},{"SOURCE_ROW_NUMBER":"111513","EVENT_NO":"6392736","SURVEY_DATE":"06/05/2014","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"89","PEL_DOSE_90":"86","SURVEY_TYPE":"I","sourceDate":"2014-06-05"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":8,"firstDate":"2014-12-01","lastDate":"2019-03-05","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":9.5,"validSamples":8,"quartzPctTotal":54.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"80501","CASSETTE_NO":"58235079","SAMPLE_DT":"03/05/2019","QUARTZ_PCT":"09.5","QUARTZ_MICROGRAMS":"79","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-03-05"},{"SOURCE_ROW_NUMBER":"77275","CASSETTE_NO":"58234899","SAMPLE_DT":"03/05/2019","QUARTZ_PCT":"08.6","QUARTZ_MICROGRAMS":"150","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-03-05"},{"SOURCE_ROW_NUMBER":"100828","CASSETTE_NO":"58281138","SAMPLE_DT":"12/11/2018","QUARTZ_PCT":"06.4","QUARTZ_MICROGRAMS":"34","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-12-11"},{"SOURCE_ROW_NUMBER":"63483","CASSETTE_NO":"58235134","SAMPLE_DT":"12/04/2018","QUARTZ_PCT":"05.7","QUARTZ_MICROGRAMS":"176","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"21995","CASSETTE_NO":"58235121","SAMPLE_DT":"12/04/2018","QUARTZ_PCT":"07.1","QUARTZ_MICROGRAMS":"42","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2018-12-04"},{"SOURCE_ROW_NUMBER":"124722","CASSETTE_NO":"58150272","SAMPLE_DT":"01/12/2015","QUARTZ_PCT":"06.5","QUARTZ_MICROGRAMS":"17","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-01-12"},{"SOURCE_ROW_NUMBER":"107961","CASSETTE_NO":"58150458","SAMPLE_DT":"01/12/2015","QUARTZ_PCT":"06.0","QUARTZ_MICROGRAMS":"12","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-01-12"},{"SOURCE_ROW_NUMBER":"22663","CASSETTE_NO":"58150333","SAMPLE_DT":"12/01/2014","QUARTZ_PCT":"04.3","QUARTZ_MICROGRAMS":"15","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-12-01"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":89,"firstDate":"2013-07-24","lastDate":"2019-02-12","metrics":{"ss":16,"amountDue":10021,"contested":0,"amountPaid":10021,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":10021},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1191252","VIOLATION_NO":"3787305","VIOLATION_ISSUE_DT":"02/12/2019","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/19/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-02-12"},{"SOURCE_ROW_NUMBER":"1191251","VIOLATION_NO":"3786460","VIOLATION_ISSUE_DT":"02/12/2019","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"02/13/2019","CONTESTED_IND":"N","sourceDate":"2019-02-12"},{"SOURCE_ROW_NUMBER":"1191250","VIOLATION_NO":"3786459","VIOLATION_ISSUE_DT":"02/12/2019","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"02/19/2019","CONTESTED_IND":"N","sourceDate":"2019-02-12"},{"SOURCE_ROW_NUMBER":"1191253","VIOLATION_NO":"8309051","VIOLATION_ISSUE_DT":"02/05/2019","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/07/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-02-05"},{"SOURCE_ROW_NUMBER":"1191249","VIOLATION_NO":"3786456","VIOLATION_ISSUE_DT":"01/24/2019","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/28/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-01-24"},{"SOURCE_ROW_NUMBER":"1191248","VIOLATION_NO":"3786455","VIOLATION_ISSUE_DT":"01/23/2019","SIG_SUB":"N","PART_SECTION":"75.1101-10","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/24/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-01-23"},{"SOURCE_ROW_NUMBER":"1191247","VIOLATION_NO":"2449532","VIOLATION_ISSUE_DT":"01/16/2019","SIG_SUB":"N","PART_SECTION":"75.1714(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/16/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-01-16"},{"SOURCE_ROW_NUMBER":"1191246","VIOLATION_NO":"2449531","VIOLATION_ISSUE_DT":"01/14/2019","SIG_SUB":"N","PART_SECTION":"75.1600-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/16/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-01-14"},{"SOURCE_ROW_NUMBER":"1191326","VIOLATION_NO":"4021518","VIOLATION_ISSUE_DT":"12/26/2018","SIG_SUB":"Y","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/26/2018","PROPOSED_PENALTY":"230","AMOUNT_DUE":"230","AMOUNT_PAID":"230","CONTESTED_IND":"N","sourceDate":"2018-12-26"},{"SOURCE_ROW_NUMBER":"1191325","VIOLATION_NO":"4021516","VIOLATION_ISSUE_DT":"12/19/2018","SIG_SUB":"Y","PART_SECTION":"70.100(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/28/2019","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2018-12-19"},{"SOURCE_ROW_NUMBER":"1191306","VIOLATION_NO":"9098398","VIOLATION_ISSUE_DT":"12/10/2018","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/10/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-12-10"},{"SOURCE_ROW_NUMBER":"1191305","VIOLATION_NO":"9098397","VIOLATION_ISSUE_DT":"12/06/2018","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/10/2018","PROPOSED_PENALTY":"118","AMOUNT_DUE":"118","AMOUNT_PAID":"118","CONTESTED_IND":"N","sourceDate":"2018-12-06"}]}],"safety":{"href":"/api/v1/mines/1519712/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519712/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1101-10","heading":"Water sprinkler systems; fire warning devices at belt drives.","id":"75.1101-10","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101-10","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Each water sprinkler system shall be equipped with a device designed to stop the belt drive in the event of a rise in temperature and each such warning device shall be capable of giving both an audible and visual warning when a fire occurs.","occurrenceCount":1},{"chapter":"I","heading":"Availability of approved self-rescue devices; instruction in use and location.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714","part":"75","subchapter":"O","subpart":"R","id":"75.1714","citation":"30 CFR 75.1714","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1600-2","heading":"Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.","id":"75.1600-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-Q/section-75.1600-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Communications","text":"(a) Telephones or equivalent two-way communication facilities provided at each working section shall be located not more than 500 feet outby the last open crosscut and not more than 800 feet from the farthest point of penetration of the working places on such section.\n\n(b) The incoming communication signal shall activate an audible alarm, distinguishable from the surrounding noise level, or a visual alarm that can be seen by a miner regularly employed on the working section.\n\n(c) If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, means shall be provided to permit continued communication in the event the mine electric power fails or is cut off; provided, however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required.\n\n(d) Trolley phones connected to the trolley wire shall be grounded in accordance with Subpart H of this part.\n\n(e) Telephones or equivalent two-way communication facilities shall be maintained in good operating condition at all times. In the event of any failure in the system that results in loss of communication, repairs shall be started immediately, and the system restored to operating condition as soon as possible.\n\n[38 FR 29999, Oct. 31, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","heading":"Respirable dust standards.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-B/section-70.100","part":"70","subchapter":"O","subpart":"B","id":"70.100","citation":"30 CFR 70.100","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519712","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}