{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519666","name":"Mine No 6","status":"Abandoned","status_date":"2013-02-16","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Letcher","nearest_town":"Benham","operator_id":"P22905","operator_name":"North Fork Coal Corporation","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C07","office":"Harlan KY Field Office","employees":0,"latitude":36.996111,"longitude":-82.855},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":137},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519666","name":"Mine No 6"},"operator":{"type":"operator","id":"P22905","name":"North Fork Coal Corporation"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"1519666","name":"Mine No 6"},"validFrom":"1994-08-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519666|C07082|1994-08-01|2010-04-18"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1519666","name":"Mine No 6"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519666|C02508|2010-04-19|2011-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1519666","name":"Mine No 6"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519666|0041211|2011-06-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22905","name":"North Fork Coal Corporation"},"object":{"type":"mine","id":"1519666","name":"Mine No 6"},"validFrom":"2012-05-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519666|P22905|2012-05-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22905","name":"North Fork Coal Corporation"},"validFrom":"2012-05-22","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519666","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519666|P22905|2012-05-22|0041211|2011-06-01|2268"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22905","name":"North Fork Coal Corporation"},"validFrom":"2012-05-22","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1519666","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519666|P22905|2012-05-22|C02508|2010-04-19|59579"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P22905","name":"North Fork Coal Corporation"},"validFrom":"2012-05-22","validTo":"2010-04-18","current":false,"derived":true,"evidenceMineId":"1519666","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519666|P22905|2012-05-22|C07082|1994-08-01|73698"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":2,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2013-02-16","lastDate":"2013-02-16","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":21,"firstDate":"2012-06-20","lastDate":"2013-02-04","metrics":{"ss":2,"delinquent":21,"recentRows":0,"paidPenalty":2633,"proposedPenalty":2715,"currentAssessment":2633},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1978934","VIOLATION_NO":"8374508","ISSUE_DT":"02/04/2013","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-02-04"},{"SOURCE_ROW_NUMBER":"1978933","VIOLATION_NO":"8374507","ISSUE_DT":"01/31/2013","CFR_STANDARD_CD":"77.207","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"1978935","VIOLATION_NO":"8399479","ISSUE_DT":"01/30/2013","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-30"},{"SOURCE_ROW_NUMBER":"1978932","VIOLATION_NO":"8374506","ISSUE_DT":"01/28/2013","CFR_STANDARD_CD":"75.1910(j)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-28"},{"SOURCE_ROW_NUMBER":"1978931","VIOLATION_NO":"8374505","ISSUE_DT":"01/28/2013","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-28"},{"SOURCE_ROW_NUMBER":"1978930","VIOLATION_NO":"8374504","ISSUE_DT":"01/23/2013","CFR_STANDARD_CD":"75.515","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"125.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-23"},{"SOURCE_ROW_NUMBER":"1978929","VIOLATION_NO":"8374503","ISSUE_DT":"01/23/2013","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-23"},{"SOURCE_ROW_NUMBER":"1470166","VIOLATION_NO":"8338961","ISSUE_DT":"12/04/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-04"},{"SOURCE_ROW_NUMBER":"1470165","VIOLATION_NO":"8338960","ISSUE_DT":"12/04/2012","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-04"},{"SOURCE_ROW_NUMBER":"1985943","VIOLATION_NO":"8374494","ISSUE_DT":"11/21/2012","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-21"},{"SOURCE_ROW_NUMBER":"1985942","VIOLATION_NO":"8374493","ISSUE_DT":"11/20/2012","CFR_STANDARD_CD":"75.1712-3(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"1985941","VIOLATION_NO":"8374492","ISSUE_DT":"11/20/2012","CFR_STANDARD_CD":"75.1107-1(a)(3)(ii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-11-20"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3,"firstDate":"2013-07-16","lastDate":"2013-07-16","metrics":{"appeals":0,"decisions":3,"recentRows":0,"decisionPenalty":821,"originalPenalty":903},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"342652","VIOLATION_NO":"8374504","DOCKET_NO":"KENT 2013-616","DECISION_DT":"07/16/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"125.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-07-16"},{"SOURCE_ROW_NUMBER":"342651","VIOLATION_NO":"8374494","DOCKET_NO":"KENT 2013-616","DECISION_DT":"07/16/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-07-16"},{"SOURCE_ROW_NUMBER":"96870","VIOLATION_NO":"8374506","DOCKET_NO":"KENT 2013-616","DECISION_DT":"07/16/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"Priscilla","JUDGE_LAST_NAME":"Rae","sourceDate":"2013-07-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":37,"firstDate":"2012-09-17","lastDate":"2013-03-27","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":5,"validSamples":32,"maxConcentration":2.836,"concentrationTotal":25.306},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1248083","CASS_NUM":"51223835","SMP_TAKEN_DT":"3/27/2013","CONC":".918","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MINE NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-27"},{"SOURCE_ROW_NUMBER":"545087","CASS_NUM":"51223553","SMP_TAKEN_DT":"3/27/2013","CONC":".802","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MINE NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-27"},{"SOURCE_ROW_NUMBER":"1169677","CASS_NUM":"51223550","SMP_TAKEN_DT":"3/26/2013","CONC":".849","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MINE NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-26"},{"SOURCE_ROW_NUMBER":"180894","CASS_NUM":"51223678","SMP_TAKEN_DT":"3/26/2013","CONC":"1.063","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MINE NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-26"},{"SOURCE_ROW_NUMBER":"1092906","CASS_NUM":"51203479","SMP_TAKEN_DT":"3/25/2013","CONC":"1.164","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MINE NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-03-25"},{"SOURCE_ROW_NUMBER":"854397","CASS_NUM":"51223639","SMP_TAKEN_DT":"2/12/2013","CONC":".185","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"1535640","CASS_NUM":"57935330","SMP_TAKEN_DT":"1/29/2013","CONC":".181","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-29"},{"SOURCE_ROW_NUMBER":"1507474","CASS_NUM":"57934224","SMP_TAKEN_DT":"1/29/2013","CONC":".434","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-29"},{"SOURCE_ROW_NUMBER":"1447235","CASS_NUM":"57935371","SMP_TAKEN_DT":"1/29/2013","CONC":".041","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-29"},{"SOURCE_ROW_NUMBER":"1442281","CASS_NUM":"57934234","SMP_TAKEN_DT":"1/29/2013","CONC":".194","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-29"},{"SOURCE_ROW_NUMBER":"1376907","CASS_NUM":"57934404","SMP_TAKEN_DT":"1/29/2013","CONC":".04","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-29"},{"SOURCE_ROW_NUMBER":"731170","CASS_NUM":"57934428","SMP_TAKEN_DT":"1/29/2013","CONC":".198","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-01-29"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2012-07-19","lastDate":"2012-12-17","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":3,"firstDate":"2012-11-21","lastDate":"2013-01-28","metrics":{"decisions":3,"ssChanged":0,"recentRows":0,"decisionPenalty":821,"proposedPenalty":903},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"427843","CITATION_NO":"8374506","CITATION_ISSUE_DT":"01/28/2013","DOCKET_NO":"KENT 2013-616","DECISION_DT":"07/16/2013","CFR_STANDARD_CODE":"75.1910(j)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2013-01-28"},{"SOURCE_ROW_NUMBER":"314039","CITATION_NO":"8374504","CITATION_ISSUE_DT":"01/23/2013","DOCKET_NO":"KENT 2013-616","DECISION_DT":"07/16/2013","CFR_STANDARD_CODE":"75.515","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"125.00","sourceDate":"2013-01-23"},{"SOURCE_ROW_NUMBER":"139214","CITATION_NO":"8374494","CITATION_ISSUE_DT":"11/21/2012","DOCKET_NO":"KENT 2013-616","DECISION_DT":"07/16/2013","CFR_STANDARD_CODE":"75.517","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"334.00","sourceDate":"2012-11-21"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2012-05-22","lastDate":"2012-05-22","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":9,"firstDate":"2012-06-05","lastDate":"2013-01-15","metrics":{"inspectors":20,"recentRows":0,"onSiteHours":215.25,"inspectionHours":366.75,"inspectionSamples":20},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"897391","EVENT_NO":"4449707","INSPECTION_BEGIN_DT":"01/15/2013","INSPECTION_END_DT":"01/16/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"25.25","SUM_TOTAL_ON_SITE_HOURS":"12.75","sourceDate":"2013-01-15"},{"SOURCE_ROW_NUMBER":"1019116","EVENT_NO":"6425813","INSPECTION_BEGIN_DT":"01/03/2013","INSPECTION_END_DT":"02/05/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"105","SUM_TOTAL_ON_SITE_HOURS":"61.5","sourceDate":"2013-01-03"},{"SOURCE_ROW_NUMBER":"170317","EVENT_NO":"6425812","INSPECTION_BEGIN_DT":"12/27/2012","INSPECTION_END_DT":"12/27/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.25","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2012-12-27"},{"SOURCE_ROW_NUMBER":"973644","EVENT_NO":"4452658","INSPECTION_BEGIN_DT":"12/04/2012","INSPECTION_END_DT":"12/04/2012","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2012-12-04"},{"SOURCE_ROW_NUMBER":"887093","EVENT_NO":"6427387","INSPECTION_BEGIN_DT":"10/15/2012","INSPECTION_END_DT":"11/26/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"128.75","SUM_TOTAL_ON_SITE_HOURS":"78.5","sourceDate":"2012-10-15"},{"SOURCE_ROW_NUMBER":"1126061","EVENT_NO":"4447399","INSPECTION_BEGIN_DT":"07/10/2012","INSPECTION_END_DT":"07/30/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"33.5","SUM_TOTAL_ON_SITE_HOURS":"20","sourceDate":"2012-07-10"},{"SOURCE_ROW_NUMBER":"882201","EVENT_NO":"4447395","INSPECTION_BEGIN_DT":"06/19/2012","INSPECTION_END_DT":"06/21/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"37.5","SUM_TOTAL_ON_SITE_HOURS":"23","sourceDate":"2012-06-19"},{"SOURCE_ROW_NUMBER":"661080","EVENT_NO":"4468831","INSPECTION_BEGIN_DT":"06/11/2012","INSPECTION_END_DT":"06/12/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"437556","EVENT_NO":"4240594","INSPECTION_BEGIN_DT":"06/05/2012","INSPECTION_END_DT":"06/07/2012","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2012-06-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013-Q1":{"hours":50925,"employees":95,"production":51824},"2012-Q4":{"hours":21897,"employees":41,"production":44564},"2012-Q3":{"hours":6430,"employees":62,"production":8270},"2012-Q2":{"hours":552,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012":{"hours":28879,"employees":36,"production":52834},"2013":{"hours":50925,"employees":95,"production":51824}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":13,"firstDate":"2012-07-17","lastDate":"2012-11-14","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":517,"pelDoseTotal":396},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"110657","EVENT_NO":"6427387","SURVEY_DATE":"11/14/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"033","ACT_DOSE_85":"23","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2012-11-14"},{"SOURCE_ROW_NUMBER":"110656","EVENT_NO":"6427387","SURVEY_DATE":"11/14/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"122","PEL_DOSE_90":"93","SURVEY_TYPE":"I","sourceDate":"2012-11-14"},{"SOURCE_ROW_NUMBER":"110655","EVENT_NO":"6427387","SURVEY_DATE":"11/14/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"74","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2012-11-14"},{"SOURCE_ROW_NUMBER":"110654","EVENT_NO":"6427387","SURVEY_DATE":"11/14/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"89","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2012-11-14"},{"SOURCE_ROW_NUMBER":"110653","EVENT_NO":"6427387","SURVEY_DATE":"11/14/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"124","PEL_DOSE_90":"118","SURVEY_TYPE":"I","sourceDate":"2012-11-14"},{"SOURCE_ROW_NUMBER":"110652","EVENT_NO":"4447399","SURVEY_DATE":"07/18/2012","OCCUPATION_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"9","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"110651","EVENT_NO":"4447399","SURVEY_DATE":"07/18/2012","OCCUPATION_CD_DESC":"SUPERINTENDENT","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"4","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"110650","EVENT_NO":"4447399","SURVEY_DATE":"07/18/2012","OCCUPATION_CD_DESC":"MAINTENANCE FOREMAN","MACHINE_CD":"20","MANUFACTURER_CD":"120","ACT_DOSE_85":"10","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"110649","EVENT_NO":"4447399","SURVEY_DATE":"07/17/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"039","ACT_DOSE_85":"14","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2012-07-17"},{"SOURCE_ROW_NUMBER":"110648","EVENT_NO":"4447399","SURVEY_DATE":"07/17/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"039","ACT_DOSE_85":"19","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2012-07-17"},{"SOURCE_ROW_NUMBER":"110647","EVENT_NO":"4447399","SURVEY_DATE":"07/17/2012","OCCUPATION_CD_DESC":"ELECTRICIAN HELPER","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"6","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2012-07-17"},{"SOURCE_ROW_NUMBER":"110646","EVENT_NO":"4447399","SURVEY_DATE":"07/17/2012","OCCUPATION_CD_DESC":"ELECTRICIAN HELPER","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"11","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2012-07-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":22,"firstDate":"2012-06-20","lastDate":"2013-02-04","metrics":{"ss":2,"amountDue":2633,"contested":0,"amountPaid":2633,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":2715},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1188727","VIOLATION_NO":"8374508","VIOLATION_ISSUE_DT":"02/04/2013","SIG_SUB":"N","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/04/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-02-04"},{"SOURCE_ROW_NUMBER":"1188726","VIOLATION_NO":"8374507","VIOLATION_ISSUE_DT":"01/31/2013","SIG_SUB":"N","PART_SECTION":"77.207","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/04/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"1188728","VIOLATION_NO":"8399479","VIOLATION_ISSUE_DT":"01/30/2013","SIG_SUB":"N","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/30/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-30"},{"SOURCE_ROW_NUMBER":"1188725","VIOLATION_NO":"8374506","VIOLATION_ISSUE_DT":"01/28/2013","SIG_SUB":"Y","PART_SECTION":"75.1910(j)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2013","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"N","sourceDate":"2013-01-28"},{"SOURCE_ROW_NUMBER":"1188724","VIOLATION_NO":"8374505","VIOLATION_ISSUE_DT":"01/28/2013","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/28/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-28"},{"SOURCE_ROW_NUMBER":"1188723","VIOLATION_NO":"8374504","VIOLATION_ISSUE_DT":"01/23/2013","SIG_SUB":"N","PART_SECTION":"75.515","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2013","PROPOSED_PENALTY":"207","AMOUNT_DUE":"125","AMOUNT_PAID":"125","CONTESTED_IND":"N","sourceDate":"2013-01-23"},{"SOURCE_ROW_NUMBER":"1188722","VIOLATION_NO":"8374503","VIOLATION_ISSUE_DT":"01/23/2013","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-23"},{"SOURCE_ROW_NUMBER":"1188743","VIOLATION_NO":"8338961","VIOLATION_ISSUE_DT":"12/04/2012","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-12-04"},{"SOURCE_ROW_NUMBER":"1188742","VIOLATION_NO":"8338960","VIOLATION_ISSUE_DT":"12/04/2012","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-12-04"},{"SOURCE_ROW_NUMBER":"1188741","VIOLATION_NO":"8374494","VIOLATION_ISSUE_DT":"11/21/2012","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/21/2012","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"334","CONTESTED_IND":"N","sourceDate":"2012-11-21"},{"SOURCE_ROW_NUMBER":"1188740","VIOLATION_NO":"8374493","VIOLATION_ISSUE_DT":"11/20/2012","SIG_SUB":"N","PART_SECTION":"75.1712-3(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/21/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"1188739","VIOLATION_NO":"8374492","VIOLATION_ISSUE_DT":"11/20/2012","SIG_SUB":"N","PART_SECTION":"75.1107-1(a)(3)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/20/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-11-20"}]}],"safety":{"href":"/api/v1/mines/1519666/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519666/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Illumination.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.207","part":"77","subchapter":"O","subpart":"C","id":"77.207","citation":"30 CFR 77.207","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1910","heading":"Nonpermissible diesel-powered equipment; electrical system design and performance requirements.","id":"75.1910","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1910","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"Electrical circuits and components associated with or connected to electrical systems on nonpermissible diesel-powered equipment utilizing storage batteries and integral charging systems, except for the special category of equipment under § 75.1908(d), must conform to the following requirements:\n\n(a) Overload and short circuit protection must be provided for electric circuits and components in accordance with §§ 75.518 and 75.518-1 of this part;\n\n(b) Each electric conductor from the battery to the starting motor must be protected against short circuit by fuses or other circuit-interrupting devices placed as near as practicable to the battery terminals;\n\n(c) Each branch circuit conductor connected to the main circuit between the battery and charging generator must be protected against short circuit by fuses or other automatic circuit-interrupting devices;\n\n(d) The electrical system shall be equipped with a circuit-interrupting device by means of which all power conductors can be deenergized. The device must be located as close as practicable to the battery terminals and be designed to operate within its electrical rating without damage. The device shall not automatically reset after being actuated. All magnetic circuit-interrupting devices must be mounted in a manner to preclude their closing by force of gravity;\n\n(e) Each motor and charging generator must be protected by an automatic overcurrent device. One protective device will be acceptable when two motors of the same rating operate simultaneously and perform virtually the same duty;\n\n(f) Each ungrounded conductor must have insulation compatible with the impressed voltage. Insulation materials must be resistant to deterioration from engine heat and oil. Electric conductors must meet the applicable requirements of §§ 75.513 and 75.513-1, except electric conductors for starting motors, which must only meet the requirements of § 75.513;\n\n(g) All wiring must have adequate mechanical protection to prevent damage to the cable that might result in short circuits;\n\n(h) Sharp edges and corners must be removed at all points where there is a possibility of damaging wires, cables, or conduits by cutting or abrasion. The insulation of the cables within a battery box must be protected against abrasion;\n\n(i) When insulated wires other than cables pass through metal frames, the holes must be substantially bushed with insulated bushings. Cables must enter metal frames of motors, splice boxes, and electric components only through proper fittings. All electrical connections and splices must be mechanically and electrically efficient, and suitable connectors shall be used. All electrical connectors or splices in insulated wire must be reinsulated at least to the same degree of protection as the remainder of the wire;\n\n(j) The battery must be secured to prevent movement, and must be protected from external damage by position. Batteries that are not protected from external damage by position must be enclosed in a battery box. Flame-resistant insulation treated to resist chemical reaction to electrolyte must be provided on battery connections to prevent battery terminals from contacting conducting surfaces;\n\n(k) A battery box, including the cover, must be constructed of steel with a minimum thickness of 1/8 inch, or of a material other than steel that provides equivalent strength;\n\n(l) Battery-box covers must be lined with a flame-resistant insulating material permanently attached to the underside of the cover, unless equivalent protection is provided. Battery-box covers must be provided with a means for securing them in closed position. At least 1/2 inch of air space must be provided between the underside of the cover and the top of the battery, including terminals;\n\n(m) Battery boxes must be provided with ventilation openings to prevent the accumulation of flammable or toxic gases or vapors within the battery box. The size and locations of openings for ventilation must prevent direct access to battery terminals;\n\n(n) The battery must be insulated from the battery-box walls and supported on insulating materials. Insulating materials that may be subject to chemical reaction with electrolyte must be treated to resist such action; and\n\n(o) Drainage holes must be provided in the bottom of each battery box.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.515","heading":"Cable fittings; suitability.","id":"75.515","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.515","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nCables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires other than cables pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","heading":"Minimum requirements of surface bathing facilities, change rooms, and sanitary toilet facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1712-3","part":"75","subchapter":"O","subpart":"R","id":"75.1712-3","citation":"30 CFR 75.1712-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Fire-resistant hydraulic fluids and fire suppression devices on underground equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-1","part":"75","subchapter":"O","subpart":"L","id":"75.1107-1","citation":"30 CFR 75.1107-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519666","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}