{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519571","name":"Mine #7","status":"Abandoned","status_date":"2015-08-04","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Whitley","nearest_town":"Rockholds","operator_id":"0091250","operator_name":"Clear Development, LLC","controller_id":"0076481","controller_name":"Justin  Clear","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.842778,"longitude":-84.104722},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":158},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519571","name":"Mine #7"},"operator":{"type":"operator","id":"0091250","name":"Clear Development, LLC"},"controller":{"type":"controller","id":"0076481","name":"Justin  Clear"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0076481","name":"Justin  Clear"},"object":{"type":"mine","id":"1519571","name":"Mine #7"},"validFrom":"2008-04-24","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519571|0076481|2008-04-24|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0091250","name":"Clear Development, LLC"},"object":{"type":"mine","id":"1519571","name":"Mine #7"},"validFrom":"2011-03-24","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519571|0091250|2011-03-24|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0076481","name":"Justin  Clear"},"object":{"type":"operator","id":"0091250","name":"Clear Development, LLC"},"validFrom":"2011-03-24","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519571","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519571|0091250|2011-03-24|0076481|2008-04-24|11979"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2011-09-17","lastDate":"2011-09-17","metrics":{"daysLost":35,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"177970","DOCUMENT_NO":"220112650007","ACCIDENT_DT":"09/17/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from machine","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"35","NARRATIVE":"Foreman was operating 992 when a hydraulic line had blown which sprayed hyd fluid on windshield & surrounding area on eq.  EE exited the loader & attempted to clean the windshield.  When he went to move to the fender or boom area, he apparently slipped on the hyd fluid and fell from the loader onto the ground causing injury to his left side.","sourceDate":"2011-09-17"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2015-08-04","lastDate":"2015-08-04","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":35,"firstDate":"2011-04-26","lastDate":"2015-03-16","metrics":{"ss":16,"delinquent":35,"recentRows":0,"paidPenalty":8912,"proposedPenalty":8912,"currentAssessment":8912},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1989783","VIOLATION_NO":"8388996","ISSUE_DT":"03/16/2015","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-03-16"},{"SOURCE_ROW_NUMBER":"1989782","VIOLATION_NO":"8388995","ISSUE_DT":"03/16/2015","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-03-16"},{"SOURCE_ROW_NUMBER":"1988867","VIOLATION_NO":"8378595","ISSUE_DT":"12/06/2012","CFR_STANDARD_CD":"77.1000","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-06"},{"SOURCE_ROW_NUMBER":"1489873","VIOLATION_NO":"8368511","ISSUE_DT":"10/19/2012","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1489872","VIOLATION_NO":"8368510","ISSUE_DT":"10/19/2012","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1489871","VIOLATION_NO":"8368509","ISSUE_DT":"10/19/2012","CFR_STANDARD_CD":"72.620","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1489870","VIOLATION_NO":"8368508","ISSUE_DT":"10/19/2012","CFR_STANDARD_CD":"72.620","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"897.00","CURRENT_ASSESSMENT_AMT":"897.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1469891","VIOLATION_NO":"8369633","ISSUE_DT":"09/20/2012","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1026.00","CURRENT_ASSESSMENT_AMT":"1026.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-20"},{"SOURCE_ROW_NUMBER":"1469890","VIOLATION_NO":"8369632","ISSUE_DT":"09/20/2012","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-20"},{"SOURCE_ROW_NUMBER":"1469889","VIOLATION_NO":"8369631","ISSUE_DT":"09/20/2012","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-20"},{"SOURCE_ROW_NUMBER":"1468488","VIOLATION_NO":"8369306","ISSUE_DT":"01/11/2012","CFR_STANDARD_CD":"77.1606(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-11"},{"SOURCE_ROW_NUMBER":"1468487","VIOLATION_NO":"8369305","ISSUE_DT":"01/11/2012","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"687.00","CURRENT_ASSESSMENT_AMT":"687.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":25,"firstDate":"2011-05-17","lastDate":"2015-03-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":1,"validSamples":24,"maxConcentration":1.05,"concentrationTotal":4.774},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"498853","CASS_NUM":"51331191","SMP_TAKEN_DT":"3/25/2015","CONC":".078","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-25"},{"SOURCE_ROW_NUMBER":"1643389","CASS_NUM":"58183998","SMP_TAKEN_DT":"3/18/2015","CONC":".047","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"1598727","CASS_NUM":"58183075","SMP_TAKEN_DT":"3/18/2015","CONC":".044","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"1516371","CASS_NUM":"58183072","SMP_TAKEN_DT":"3/18/2015","CONC":".043","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"394350","CASS_NUM":"58184058","SMP_TAKEN_DT":"3/18/2015","CONC":".241","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL STRIP OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"330128","CASS_NUM":"58184250","SMP_TAKEN_DT":"3/18/2015","CONC":".07","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"870824","CASS_NUM":"51290520","SMP_TAKEN_DT":"2/25/2015","CONC":".118","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-02-25"},{"SOURCE_ROW_NUMBER":"395129","CASS_NUM":"51290322","SMP_TAKEN_DT":"2/4/2015","CONC":".118","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHWALL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-02-04"},{"SOURCE_ROW_NUMBER":"1230377","CASS_NUM":"51110533","SMP_TAKEN_DT":"11/8/2012","CONC":".105","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-08"},{"SOURCE_ROW_NUMBER":"1253252","CASS_NUM":"51110532","SMP_TAKEN_DT":"11/1/2012","CONC":".063","SMP_TYPE_CD_DESC":"DESIGNATED WORK POSITION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-01"},{"SOURCE_ROW_NUMBER":"1657082","CASS_NUM":"57975327","SMP_TAKEN_DT":"9/10/2012","CONC":".669","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"1391634","CASS_NUM":"57975528","SMP_TAKEN_DT":"9/10/2012","CONC":".212","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BULLDOZER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-10"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2011-03-24","lastDate":"2011-03-24","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":16,"firstDate":"2011-04-11","lastDate":"2015-08-04","metrics":{"inspectors":23,"recentRows":0,"onSiteHours":207,"inspectionHours":352,"inspectionSamples":36},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"374252","EVENT_NO":"6429669","INSPECTION_BEGIN_DT":"08/04/2015","INSPECTION_END_DT":"08/04/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2015-08-04"},{"SOURCE_ROW_NUMBER":"418963","EVENT_NO":"6428311","INSPECTION_BEGIN_DT":"03/10/2015","INSPECTION_END_DT":"03/23/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"47.5","SUM_TOTAL_ON_SITE_HOURS":"28.75","sourceDate":"2015-03-10"},{"SOURCE_ROW_NUMBER":"666351","EVENT_NO":"6429633","INSPECTION_BEGIN_DT":"01/13/2015","INSPECTION_END_DT":"01/13/2015","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2015-01-13"},{"SOURCE_ROW_NUMBER":"1104529","EVENT_NO":"6429617","INSPECTION_BEGIN_DT":"10/30/2014","INSPECTION_END_DT":"10/30/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2014-10-30"},{"SOURCE_ROW_NUMBER":"911216","EVENT_NO":"6429590","INSPECTION_BEGIN_DT":"07/14/2014","INSPECTION_END_DT":"07/14/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2014-07-14"},{"SOURCE_ROW_NUMBER":"677794","EVENT_NO":"6429532","INSPECTION_BEGIN_DT":"12/24/2013","INSPECTION_END_DT":"12/24/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2013-12-24"},{"SOURCE_ROW_NUMBER":"45745","EVENT_NO":"6428166","INSPECTION_BEGIN_DT":"07/23/2013","INSPECTION_END_DT":"07/23/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2013-07-23"},{"SOURCE_ROW_NUMBER":"107632","EVENT_NO":"6428123","INSPECTION_BEGIN_DT":"12/06/2012","INSPECTION_END_DT":"03/15/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2012-12-06"},{"SOURCE_ROW_NUMBER":"408668","EVENT_NO":"4468274","INSPECTION_BEGIN_DT":"10/19/2012","INSPECTION_END_DT":"11/26/2012","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"855604","EVENT_NO":"4452464","INSPECTION_BEGIN_DT":"06/21/2012","INSPECTION_END_DT":"09/24/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"45","SUM_TOTAL_ON_SITE_HOURS":"23.75","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"227405","EVENT_NO":"4452161","INSPECTION_BEGIN_DT":"01/11/2012","INSPECTION_END_DT":"01/25/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"40.75","SUM_TOTAL_ON_SITE_HOURS":"16.5","sourceDate":"2012-01-11"},{"SOURCE_ROW_NUMBER":"882516","EVENT_NO":"4451985","INSPECTION_BEGIN_DT":"12/14/2011","INSPECTION_END_DT":"12/14/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2011-12-14"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2015-Q3":{"hours":0,"employees":0,"production":0},"2015-Q2":{"hours":990,"employees":4,"production":1262},"2015-Q1":{"hours":2441,"employees":5,"production":2671},"2014-Q4":{"hours":0,"employees":0,"production":0},"2014-Q3":{"hours":0,"employees":0,"production":0},"2014-Q2":{"hours":0,"employees":0,"production":0},"2013-Q1":{"hours":0,"employees":0,"production":0},"2012-Q4":{"hours":2854,"employees":10,"production":9062},"2012-Q3":{"hours":2631,"employees":10,"production":7440},"2012-Q2":{"hours":571,"employees":3,"production":364},"2012-Q1":{"hours":7632,"employees":12,"production":26399},"2011-Q4":{"hours":11229,"employees":16,"production":24975}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":25915,"employees":13,"production":67396},"2012":{"hours":13688,"employees":9,"production":43265},"2015":{"hours":3431,"employees":5,"production":3933}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":18,"firstDate":"2011-05-17","lastDate":"2015-03-18","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":992,"pelDoseTotal":455},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"109476","EVENT_NO":"6428311","SURVEY_DATE":"03/18/2015","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"26","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"109475","EVENT_NO":"6428311","SURVEY_DATE":"03/18/2015","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"46","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"109474","EVENT_NO":"6428311","SURVEY_DATE":"03/18/2015","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"119","ACT_DOSE_85":"46","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"109473","EVENT_NO":"6428311","SURVEY_DATE":"03/18/2015","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"37","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2015-03-18"},{"SOURCE_ROW_NUMBER":"109467","EVENT_NO":"4452464","SURVEY_DATE":"09/10/2012","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"94","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"109466","EVENT_NO":"4452464","SURVEY_DATE":"09/10/2012","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"60","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"109465","EVENT_NO":"4452464","SURVEY_DATE":"09/10/2012","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"86","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"109464","EVENT_NO":"4452464","SURVEY_DATE":"09/10/2012","OCCUPATION_CD_DESC":"HIGHWALL DRILL OPERATOR","MACHINE_CD":"21","MANUFACTURER_CD":"105","ACT_DOSE_85":"86","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"109472","EVENT_NO":"6425669","SURVEY_DATE":"10/27/2011","OCCUPATION_CD_DESC":"BULLDOZER OPERATOR","MACHINE_CD":"03","MANUFACTURER_CD":"018","ACT_DOSE_85":"83","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"109471","EVENT_NO":"6425669","SURVEY_DATE":"10/27/2011","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"49","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"109470","EVENT_NO":"6425669","SURVEY_DATE":"10/27/2011","OCCUPATION_CD_DESC":"REFUSE TRUCK DRIVER/BACKFILL TRUCK DRIVE","MACHINE_CD":"39","MANUFACTURER_CD":"018","ACT_DOSE_85":"100","PEL_DOSE_90":"69","SURVEY_TYPE":"I","sourceDate":"2011-10-27"},{"SOURCE_ROW_NUMBER":"109469","EVENT_NO":"6425669","SURVEY_DATE":"10/27/2011","OCCUPATION_CD_DESC":"BACKHOE OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"018","ACT_DOSE_85":"27","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2011-10-27"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":2,"firstDate":"2012-09-10","lastDate":"2012-09-10","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":33.8,"validSamples":2,"quartzPctTotal":45},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"129472","CASSETTE_NO":"57975417","SAMPLE_DT":"09/10/2012","QUARTZ_PCT":"11.2","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"13468","CASSETTE_NO":"57975528","SAMPLE_DT":"09/10/2012","QUARTZ_PCT":"33.8","OCC_CODE_DESC":"BULLDOZER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED WORK POSITION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-09-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":41,"firstDate":"2011-04-26","lastDate":"2015-03-16","metrics":{"ss":16,"amountDue":8912,"contested":0,"amountPaid":8912,"recentRows":0,"section104d":0,"unterminated":5,"proposedPenalty":8912},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1185737","VIOLATION_NO":"8388996","VIOLATION_ISSUE_DT":"03/16/2015","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/16/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-03-16"},{"SOURCE_ROW_NUMBER":"1185736","VIOLATION_NO":"8388995","VIOLATION_ISSUE_DT":"03/16/2015","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/16/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-03-16"},{"SOURCE_ROW_NUMBER":"1185765","VIOLATION_NO":"8378595","VIOLATION_ISSUE_DT":"12/06/2012","SIG_SUB":"N","PART_SECTION":"77.1000","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/06/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-12-06"},{"SOURCE_ROW_NUMBER":"1185764","VIOLATION_NO":"8368514","VIOLATION_ISSUE_DT":"11/20/2012","PART_SECTION":"72.620","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/09/2013","CONTESTED_IND":"N","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"1185763","VIOLATION_NO":"8368513","VIOLATION_ISSUE_DT":"11/20/2012","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"12/09/2013","CONTESTED_IND":"N","sourceDate":"2012-11-20"},{"SOURCE_ROW_NUMBER":"1185762","VIOLATION_NO":"8368511","VIOLATION_ISSUE_DT":"10/19/2012","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/02/2012","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1185761","VIOLATION_NO":"8368510","VIOLATION_ISSUE_DT":"10/19/2012","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1185760","VIOLATION_NO":"8368509","VIOLATION_ISSUE_DT":"10/19/2012","SIG_SUB":"N","PART_SECTION":"72.620","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/20/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1185759","VIOLATION_NO":"8368508","VIOLATION_ISSUE_DT":"10/19/2012","SIG_SUB":"Y","PART_SECTION":"72.620","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"897","AMOUNT_DUE":"897","AMOUNT_PAID":"897","CONTESTED_IND":"N","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"1185754","VIOLATION_NO":"8369633","VIOLATION_ISSUE_DT":"09/20/2012","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/24/2012","PROPOSED_PENALTY":"1026","AMOUNT_DUE":"1026","AMOUNT_PAID":"1026","CONTESTED_IND":"N","sourceDate":"2012-09-20"},{"SOURCE_ROW_NUMBER":"1185753","VIOLATION_NO":"8369632","VIOLATION_ISSUE_DT":"09/20/2012","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/24/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-20"},{"SOURCE_ROW_NUMBER":"1185752","VIOLATION_NO":"8369631","VIOLATION_ISSUE_DT":"09/20/2012","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/20/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-09-20"}]}],"safety":{"href":"/api/v1/mines/1519571/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519571/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","heading":"Highwalls, pits and spoil banks; plans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-K/section-77.1000","part":"77","subchapter":"O","subpart":"K","id":"77.1000","citation":"30 CFR 77.1000","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Drill dust control at surface mines and surface areas of underground mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.620","part":"72","subchapter":"O","subpart":"E","id":"72.620","citation":"30 CFR 72.620","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subpartHeading":"","text":null,"occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":5},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519571","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}