{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519567","name":"Liggett #8","status":"Abandoned and Sealed","status_date":"2014-12-31","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Harlan","nearest_town":"Harlan","operator_id":"0051884","operator_name":"Liggett Mining LLC","controller_id":"C04355","controller_name":"James C  Justice II","district":"C07","office":"Harlan KY Field Office","employees":0,"latitude":36.787222,"longitude":-83.357778},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":666},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519567","name":"Liggett #8"},"operator":{"type":"operator","id":"0051884","name":"Liggett Mining LLC"},"controller":{"type":"controller","id":"C04355","name":"James C  Justice II"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C12998","name":"Stanley R  Ditty"},"object":{"type":"mine","id":"1519567","name":"Liggett #8"},"validFrom":"2003-11-26","validTo":"2007-07-19","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519567|C12998|2003-11-26|2007-07-19"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"mine","id":"1519567","name":"Liggett #8"},"validFrom":"2007-07-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519567|C04355|2007-07-20|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051884","name":"Liggett Mining LLC"},"object":{"type":"mine","id":"1519567","name":"Liggett #8"},"validFrom":"2011-03-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519567|0051884|2011-03-04|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C04355","name":"James C  Justice II et al"},"object":{"type":"operator","id":"0051884","name":"Liggett Mining LLC"},"validFrom":"2011-03-04","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519567","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519567|0051884|2011-03-04|C04355|2007-07-20|65543"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C12998","name":"Stanley R  Ditty"},"object":{"type":"operator","id":"0051884","name":"Liggett Mining LLC"},"validFrom":"2011-03-04","validTo":"2007-07-19","current":false,"derived":true,"evidenceMineId":"1519567","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519567|0051884|2011-03-04|C12998|2003-11-26|88379"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":5,"firstDate":"2012-04-18","lastDate":"2013-04-12","metrics":{"daysLost":446,"injuries":5,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"212367","DOCUMENT_NO":"220131120030","ACCIDENT_DT":"04/12/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"171","NARRATIVE":"The employee was dragging an oxygen tank to the continuous miner, to assist in making repairs to this machine. When the employee attempted to stand the oxygen tank up, he stated he felt pain and burning in his lower back.","sourceDate":"2013-04-12"},{"SOURCE_ROW_NUMBER":"130400","DOCUMENT_NO":"220130980026","ACCIDENT_DT":"04/01/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"44","NARRATIVE":"fracture of left leg below knee cap","sourceDate":"2013-04-01"},{"SOURCE_ROW_NUMBER":"268255","DOCUMENT_NO":"220130840042","ACCIDENT_DT":"03/20/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"16","NARRATIVE":"EMPLOYEE WAS LOADING A BROKEN HEAD-JACK PIN, FROM THE CONTINUOUS MINER, ONTO THE SCOOP, AND MASHED HIS RIGHT, MIDDLE FINGER BETWEEN THE PIN AND THE SCOOP, CAUSING A LACERATION.","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"242585","DOCUMENT_NO":"220121170014","ACCIDENT_DT":"04/25/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Mechanic helper","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"The injured person had raised a lid on the continuous miner and did not hinge it all the way to the rear. The lid closed on his right index finger.","sourceDate":"2012-04-25"},{"SOURCE_ROW_NUMBER":"70307","DOCUMENT_NO":"220121170013","ACCIDENT_DT":"04/18/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"195","NARRATIVE":"The accident victim was shoveling loose coal along the belt line. When attempting to unload the shovel, it came in contact with the belt line causing the shovel to wedge against the mine roof, straining the victims shoulder.","sourceDate":"2012-04-18"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-12-31","lastDate":"2014-12-31","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":136,"firstDate":"2012-01-04","lastDate":"2014-03-12","metrics":{"ss":28,"delinquent":136,"recentRows":0,"paidPenalty":19039,"proposedPenalty":21871,"currentAssessment":19539},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1980294","VIOLATION_NO":"8397197","ISSUE_DT":"03/12/2014","CFR_STANDARD_CD":"75.1506(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"1992222","VIOLATION_NO":"8396641","ISSUE_DT":"09/25/2013","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"1992221","VIOLATION_NO":"8396640","ISSUE_DT":"09/25/2013","CFR_STANDARD_CD":"75.1600-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"1989879","VIOLATION_NO":"8396626","ISSUE_DT":"04/30/2013","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1989878","VIOLATION_NO":"8396625","ISSUE_DT":"04/30/2013","CFR_STANDARD_CD":"75.605","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1989877","VIOLATION_NO":"8396624","ISSUE_DT":"04/30/2013","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1989876","VIOLATION_NO":"8396623","ISSUE_DT":"04/30/2013","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1989875","VIOLATION_NO":"8396620","ISSUE_DT":"04/25/2013","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-25"},{"SOURCE_ROW_NUMBER":"1989874","VIOLATION_NO":"8396616","ISSUE_DT":"04/17/2013","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-17"},{"SOURCE_ROW_NUMBER":"1989873","VIOLATION_NO":"8396615","ISSUE_DT":"04/11/2013","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-11"},{"SOURCE_ROW_NUMBER":"1470180","VIOLATION_NO":"8338969","ISSUE_DT":"03/14/2013","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-14"},{"SOURCE_ROW_NUMBER":"1469330","VIOLATION_NO":"8382017","ISSUE_DT":"03/04/2013","CFR_STANDARD_CD":"77.208(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-04"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":47,"firstDate":"2013-08-20","lastDate":"2014-04-01","metrics":{"appeals":0,"decisions":47,"recentRows":0,"decisionPenalty":7846,"originalPenalty":10178},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"349941","VIOLATION_NO":"8374169","DOCKET_NO":"KENT 2014-11","DECISION_DT":"04/01/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"150.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-04-01"},{"SOURCE_ROW_NUMBER":"349584","VIOLATION_NO":"8374346","DOCKET_NO":"KENT 2014-11","DECISION_DT":"04/01/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-04-01"},{"SOURCE_ROW_NUMBER":"101531","VIOLATION_NO":"8374171","DOCKET_NO":"KENT 2014-11","DECISION_DT":"04/01/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"150.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-04-01"},{"SOURCE_ROW_NUMBER":"342337","VIOLATION_NO":"8397926","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"138.00","DECISION_PENALTY_AMT":"138.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"342336","VIOLATION_NO":"8397921","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"101.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"342335","VIOLATION_NO":"8397919","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"342334","VIOLATION_NO":"8374347","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"127.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"342333","VIOLATION_NO":"8374345","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"150.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"341790","VIOLATION_NO":"8397916","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"341789","VIOLATION_NO":"8397915","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"341614","VIOLATION_NO":"8397912","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"341541","VIOLATION_NO":"8397920","DOCKET_NO":"KENT 2013-655","DECISION_DT":"03/05/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2014-03-05"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":180,"firstDate":"2012-01-10","lastDate":"2031-01-13","metrics":{"recentRows":1,"cpdmSamples":0,"voidSamples":4,"validSamples":176,"maxConcentration":3.636,"concentrationTotal":78.222},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"320703","CASS_NUM":"57934475","SMP_TAKEN_DT":"1/13/2031","CONC":".136","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2031-01-13"},{"SOURCE_ROW_NUMBER":"329399","CASS_NUM":"51241011","SMP_TAKEN_DT":"5/9/2013","CONC":".257","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-05-09"},{"SOURCE_ROW_NUMBER":"1296443","CASS_NUM":"51241088","SMP_TAKEN_DT":"5/8/2013","CONC":".506","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-05-08"},{"SOURCE_ROW_NUMBER":"473279","CASS_NUM":"51241022","SMP_TAKEN_DT":"5/8/2013","CONC":".176","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-05-08"},{"SOURCE_ROW_NUMBER":"330779","CASS_NUM":"51241069","SMP_TAKEN_DT":"5/7/2013","CONC":".263","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"138010","CASS_NUM":"51241121","SMP_TAKEN_DT":"5/7/2013","CONC":".615","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-05-07"},{"SOURCE_ROW_NUMBER":"1623059","CASS_NUM":"57992386","SMP_TAKEN_DT":"4/24/2013","CONC":".149","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-24"},{"SOURCE_ROW_NUMBER":"1406970","CASS_NUM":"57992277","SMP_TAKEN_DT":"4/24/2013","CONC":".044","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-24"},{"SOURCE_ROW_NUMBER":"1327284","CASS_NUM":"57992420","SMP_TAKEN_DT":"4/24/2013","CONC":".037","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-24"},{"SOURCE_ROW_NUMBER":"976039","CASS_NUM":"57992613","SMP_TAKEN_DT":"4/24/2013","CONC":".383","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-24"},{"SOURCE_ROW_NUMBER":"799560","CASS_NUM":"57992478","SMP_TAKEN_DT":"4/24/2013","CONC":".166","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-24"},{"SOURCE_ROW_NUMBER":"433893","CASS_NUM":"57992489","SMP_TAKEN_DT":"4/24/2013","CONC":".274","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2013-04-24"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":47,"firstDate":"2012-01-04","lastDate":"2013-03-04","metrics":{"decisions":47,"ssChanged":3,"recentRows":0,"decisionPenalty":7846,"proposedPenalty":10178},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"429278","CITATION_NO":"8379042","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.1722(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"426991","CITATION_NO":"8382015","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.333(b)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"263.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"367715","CITATION_NO":"8374168","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"258290","CITATION_NO":"8374170","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"257279","CITATION_NO":"8374171","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2014-11","DECISION_DT":"04/01/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"150.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"254628","CITATION_NO":"8382016","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.333(b)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"263.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"200220","CITATION_NO":"8382017","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"77.208(d)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"145606","CITATION_NO":"8374169","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2014-11","DECISION_DT":"04/01/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"150.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"143374","CITATION_NO":"8374167","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"91726","CITATION_NO":"8382014","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.1100-2(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"308.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"89511","CITATION_NO":"8379041","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"468.00","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"89510","CITATION_NO":"8374166","CITATION_ISSUE_DT":"03/04/2013","DOCKET_NO":"KENT 2013-717","DECISION_DT":"12/20/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2013-03-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2011-03-04","lastDate":"2011-03-04","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":24,"firstDate":"2011-10-13","lastDate":"2014-10-01","metrics":{"inspectors":58,"recentRows":0,"onSiteHours":1091.25,"inspectionHours":1519.25,"inspectionSamples":125},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"671894","EVENT_NO":"6429237","INSPECTION_BEGIN_DT":"10/01/2014","INSPECTION_END_DT":"10/06/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.75","SUM_TOTAL_ON_SITE_HOURS":"1.75","sourceDate":"2014-10-01"},{"SOURCE_ROW_NUMBER":"22680","EVENT_NO":"6426077","INSPECTION_BEGIN_DT":"07/07/2014","INSPECTION_END_DT":"07/30/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2014-07-07"},{"SOURCE_ROW_NUMBER":"1038381","EVENT_NO":"6429230","INSPECTION_BEGIN_DT":"04/18/2014","INSPECTION_END_DT":"05/27/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2014-04-18"},{"SOURCE_ROW_NUMBER":"1120522","EVENT_NO":"6426147","INSPECTION_BEGIN_DT":"03/12/2014","INSPECTION_END_DT":"03/26/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.5","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"445423","EVENT_NO":"6426047","INSPECTION_BEGIN_DT":"12/13/2013","INSPECTION_END_DT":"12/30/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"26.75","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2013-12-13"},{"SOURCE_ROW_NUMBER":"379460","EVENT_NO":"4467875","INSPECTION_BEGIN_DT":"10/23/2013","INSPECTION_END_DT":"10/23/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2013-10-23"},{"SOURCE_ROW_NUMBER":"1101304","EVENT_NO":"6429127","INSPECTION_BEGIN_DT":"09/19/2013","INSPECTION_END_DT":"09/26/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"36","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2013-09-19"},{"SOURCE_ROW_NUMBER":"398147","EVENT_NO":"6428337","INSPECTION_BEGIN_DT":"04/08/2013","INSPECTION_END_DT":"05/24/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"155.75","SUM_TOTAL_ON_SITE_HOURS":"111.25","sourceDate":"2013-04-08"},{"SOURCE_ROW_NUMBER":"486854","EVENT_NO":"4449405","INSPECTION_BEGIN_DT":"03/21/2013","INSPECTION_END_DT":"03/21/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2013-03-21"},{"SOURCE_ROW_NUMBER":"717693","EVENT_NO":"4452662","INSPECTION_BEGIN_DT":"03/14/2013","INSPECTION_END_DT":"03/14/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2013-03-14"},{"SOURCE_ROW_NUMBER":"290723","EVENT_NO":"4452367","INSPECTION_BEGIN_DT":"03/04/2013","INSPECTION_END_DT":"03/07/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"58.5","SUM_TOTAL_ON_SITE_HOURS":"32.5","sourceDate":"2013-03-04"},{"SOURCE_ROW_NUMBER":"602737","EVENT_NO":"6426174","INSPECTION_BEGIN_DT":"01/02/2013","INSPECTION_END_DT":"03/04/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"166.5","SUM_TOTAL_ON_SITE_HOURS":"124.25","sourceDate":"2013-01-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":23,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014-Q4":{"hours":0,"employees":0,"production":0},"2014-Q3":{"hours":0,"employees":0,"production":0},"2014-Q2":{"hours":80,"employees":1,"production":0},"2014-Q1":{"hours":560,"employees":1,"production":0},"2013-Q4":{"hours":2185,"employees":4,"production":0},"2013-Q3":{"hours":1813,"employees":4,"production":0},"2013-Q2":{"hours":12113,"employees":26,"production":7405},"2013-Q1":{"hours":39567,"employees":57,"production":18017},"2012-Q4":{"hours":36464,"employees":62,"production":16140},"2012-Q3":{"hours":32797,"employees":56,"production":77971},"2012-Q2":{"hours":41688,"employees":67,"production":86561},"2012-Q1":{"hours":24001,"employees":42,"production":67688}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":5426,"employees":36,"production":4256},"2012":{"hours":134950,"employees":57,"production":248360},"2013":{"hours":55678,"employees":23,"production":25422},"2014":{"hours":640,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":35,"firstDate":"2012-02-15","lastDate":"2013-01-31","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":2659,"pelDoseTotal":1968},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"109423","EVENT_NO":"6426174","SURVEY_DATE":"01/31/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"098","ACT_DOSE_85":"84","PEL_DOSE_90":"72","SURVEY_TYPE":"I","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"109422","EVENT_NO":"6426174","SURVEY_DATE":"01/31/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"098","ACT_DOSE_85":"75","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"109421","EVENT_NO":"6426174","SURVEY_DATE":"01/31/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"54","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"109420","EVENT_NO":"6426174","SURVEY_DATE":"01/31/2013","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"94","PEL_DOSE_90":"66","SURVEY_TYPE":"I","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"109419","EVENT_NO":"6426174","SURVEY_DATE":"01/31/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"098","ACT_DOSE_85":"108","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"109398","EVENT_NO":"4447089","SURVEY_DATE":"04/26/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"96","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2012-04-26"},{"SOURCE_ROW_NUMBER":"109397","EVENT_NO":"4447089","SURVEY_DATE":"04/26/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"92","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2012-04-26"},{"SOURCE_ROW_NUMBER":"109396","EVENT_NO":"4447089","SURVEY_DATE":"04/26/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"79","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2012-04-26"},{"SOURCE_ROW_NUMBER":"109395","EVENT_NO":"4447089","SURVEY_DATE":"04/26/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2012-04-26"},{"SOURCE_ROW_NUMBER":"109394","EVENT_NO":"4447089","SURVEY_DATE":"04/26/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"133","PEL_DOSE_90":"122","SURVEY_TYPE":"I","sourceDate":"2012-04-26"},{"SOURCE_ROW_NUMBER":"109393","EVENT_NO":"4447089","SURVEY_DATE":"04/25/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"69","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2012-04-25"},{"SOURCE_ROW_NUMBER":"109392","EVENT_NO":"4447089","SURVEY_DATE":"04/25/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"81","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2012-04-25"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":7,"firstDate":"2012-03-14","lastDate":"2012-10-03","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":24.4,"validSamples":6,"quartzPctTotal":53.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"48531","CASSETTE_NO":"58001916","SAMPLE_DT":"10/03/2012","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-10-03"},{"SOURCE_ROW_NUMBER":"77472","CASSETTE_NO":"51151605","SAMPLE_DT":"08/01/2012","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2012-08-01"},{"SOURCE_ROW_NUMBER":"129835","CASSETTE_NO":"51151218","SAMPLE_DT":"04/20/2012","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-20"},{"SOURCE_ROW_NUMBER":"165956","CASSETTE_NO":"57912867","SAMPLE_DT":"03/27/2012","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-27"},{"SOURCE_ROW_NUMBER":"75634","CASSETTE_NO":"57934185","SAMPLE_DT":"03/15/2012","QUARTZ_PCT":"24.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-15"},{"SOURCE_ROW_NUMBER":"83444","CASSETTE_NO":"57934284","SAMPLE_DT":"03/14/2012","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-14"},{"SOURCE_ROW_NUMBER":"64158","CASSETTE_NO":"57934350","SAMPLE_DT":"03/14/2012","QUARTZ_PCT":"04.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-14"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":138,"firstDate":"2012-01-04","lastDate":"2014-03-12","metrics":{"ss":28,"amountDue":19539,"contested":0,"amountPaid":19039,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":21871},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1185568","VIOLATION_NO":"8397197","VIOLATION_ISSUE_DT":"03/12/2014","SIG_SUB":"N","PART_SECTION":"75.1506(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/18/2014","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2014-03-12"},{"SOURCE_ROW_NUMBER":"1185617","VIOLATION_NO":"8396641","VIOLATION_ISSUE_DT":"09/25/2013","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/25/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"1185616","VIOLATION_NO":"8396640","VIOLATION_ISSUE_DT":"09/25/2013","SIG_SUB":"N","PART_SECTION":"75.1600-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/25/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-09-25"},{"SOURCE_ROW_NUMBER":"1185597","VIOLATION_NO":"8396626","VIOLATION_ISSUE_DT":"04/30/2013","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/23/2013","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1185596","VIOLATION_NO":"8396625","VIOLATION_ISSUE_DT":"04/30/2013","SIG_SUB":"N","PART_SECTION":"75.605","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1185595","VIOLATION_NO":"8396624","VIOLATION_ISSUE_DT":"04/30/2013","SIG_SUB":"N","SECTION_OF_ACT":"316(b)(2)(A)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/07/2013","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1185594","VIOLATION_NO":"8396623","VIOLATION_ISSUE_DT":"04/30/2013","SIG_SUB":"N","SECTION_OF_ACT":"316(b)(2)(A)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/07/2013","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2013-04-30"},{"SOURCE_ROW_NUMBER":"1185593","VIOLATION_NO":"8396620","VIOLATION_ISSUE_DT":"04/25/2013","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/07/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2013-04-25"},{"SOURCE_ROW_NUMBER":"1185592","VIOLATION_NO":"8396616","VIOLATION_ISSUE_DT":"04/17/2013","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/17/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-04-17"},{"SOURCE_ROW_NUMBER":"1185591","VIOLATION_NO":"8396615","VIOLATION_ISSUE_DT":"04/11/2013","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/11/2013","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2013-04-11"},{"SOURCE_ROW_NUMBER":"1185569","VIOLATION_NO":"8338969","VIOLATION_ISSUE_DT":"03/14/2013","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/14/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-03-14"},{"SOURCE_ROW_NUMBER":"1185567","VIOLATION_NO":"8382017","VIOLATION_ISSUE_DT":"03/04/2013","SIG_SUB":"N","PART_SECTION":"77.208(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/04/2013","PROPOSED_PENALTY":"392","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-03-04"}]}],"safety":{"href":"/api/v1/mines/1519567/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519567/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1506","heading":"Refuge alternatives.","id":"75.1506","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1506","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Each operator shall provide refuge alternatives and components as follows:\n\n(1) Prefabricated self-contained units, including the structural, breathable air, air monitoring, and harmful gas removal components of the unit, shall be approved under 30 CFR part 7; and\n\n(2) The structural components of units consisting of 15 psi stoppings constructed prior to an event shall be approved by the District Manager, and the breathable air, air monitoring, and harmful gas removal components of these units shall be approved under 30 CFR part 7.\n\n(3) Prefabricated refuge alternative structures that states have approved and those that MSHA has accepted in approved Emergency Response Plans (ERPs) that are in service prior to March 2, 2009 are permitted until December 31, 2018, or until replaced, whichever comes first. Breathable air, air-monitoring, and harmful gas removal components of either a prefabricated self-contained unit or a unit consisting of 15 psi stoppings constructed prior to an event in a secure space and an isolated atmosphere that states have approved and those that MSHA has accepted in approved ERPs that are in use prior to March 2, 2009 are permitted until December 31, 2013, or until replaced, whichever comes first. Refuge alternatives consisting of materials pre-positioned for miners to deploy in a secure space with an isolated atmosphere that MSHA has accepted in approved ERPs that are in use prior to March 2, 2009 are permitted until December 31, 2010, or until replaced, whichever comes first.\n\n(b) Except as permitted under paragraph (a)(3) of this section, each operator shall provide refuge alternatives with sufficient capacity to accommodate all persons working underground.\n\n(1) Refuge alternatives shall provide at least 15 square feet of floor space per person and 30 to 60 cubic feet of volume per person according to the following chart. The airlock can be included in the space and volume if waste is disposed outside the refuge alternative.\n\nMining height (inches) Unrestricted volume(cubic feet) per person* 36 or less 30 >36-≤42 37.5 >42-≤48 45 >48-≤54 52.5 >54 60 * Includes an adjustment of 12 inches for clearances.\n\n(2) Refuge alternatives for working sections shall accommodate the maximum number of persons that can be expected on or near the section at any time.\n\n(3) Each refuge alternative for outby areas shall accommodate persons reasonably expected to use it.\n\n(c) Refuge alternatives shall be provided at the following locations:\n\n(1) Within 1,000 feet from the nearest working face and from locations where mechanized mining equipment is being installed or removed except that for underground anthracite coal mines that have no electrical face equipment, refuge alternatives shall be provided if the nearest working face is greater than 2,000 feet from the surface.\n\n(2) Spaced within one-hour travel distances in outby areas where persons work such that persons in outby areas are never more than a 30-minute travel distance from a refuge alternative or safe exit. However, the operator may request and the District Manager may approve a different location in the ERP. The operator's request shall be based on an assessment of the risk to persons in outby areas, considering the following factors: proximity to seals; proximity to potential fire or ignition sources; conditions in the outby areas; location of stored SCSRs; and proximity to the most direct, safe, and practical route to an intake escapeway.\n\n(d) Roof and rib support for refuge alternative locations shall be specified in the mine's roof control plan.\n\n(e) The operator shall protect the refuge alternative and contents from damage during transportation, installation, and storage.\n\n(f) A refuge alternative shall be removed from service if examination reveals damage that interferes with the functioning of the refuge alternative or any component.\n\n(1) If a refuge alternative is removed from service, the operator shall withdraw all persons from the area serviced by the refuge alternative, except those persons referred to in § 104(c) of the Mine Act.\n\n(2) Refuge alternative components removed from service shall be replaced or be repaired for return to service in accordance with the manufacturer's specifications.\n\n(g) At all times, the site and area around the refuge alternative shall be kept clear of machinery, materials, and obstructions that could interfere with the deployment or use of the refuge alternative.\n\n(h) Each refuge alternative shall be conspicuously identified with a sign or marker as follows:\n\n(1) A sign or marker made of a reflective material with the word “REFUGE” shall be posted conspicuously at each refuge alternative.\n\n(2) Directional signs made of a reflective material shall be posted leading to each refuge alternative location.\n\n(i) During use of the refuge alternative, the atmosphere within the refuge alternative shall be monitored. Changes or adjustments shall be made to reduce the concentration of methane to less than 1 percent; to reduce the concentration of carbon dioxide to 1 percent or less and excursions not exceeding 2.5 percent; and to reduce the concentration of carbon monoxide to 25 ppm or less. Oxygen shall be maintained at 18.5 to 23 percent.\n\n(j) Refuge alternatives shall contain a fire extinguisher that—\n\n(1) Meets the requirements for portable fire extinguishers used in underground coal mines under this part;\n\n(2) Is appropriate for extinguishing fires involving the chemicals used for harmful gas removal; and\n\n(3) Uses a low-toxicity extinguishing agent that does not produce a hazardous by-product when activated.\n\n[73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1600-2","heading":"Communication facilities; working sections; installation and maintenance requirements; audible or visual alarms.","id":"75.1600-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-Q/section-75.1600-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Communications","text":"(a) Telephones or equivalent two-way communication facilities provided at each working section shall be located not more than 500 feet outby the last open crosscut and not more than 800 feet from the farthest point of penetration of the working places on such section.\n\n(b) The incoming communication signal shall activate an audible alarm, distinguishable from the surrounding noise level, or a visual alarm that can be seen by a miner regularly employed on the working section.\n\n(c) If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, means shall be provided to permit continued communication in the event the mine electric power fails or is cut off; provided, however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required.\n\n(d) Trolley phones connected to the trolley wire shall be grounded in accordance with Subpart H of this part.\n\n(e) Telephones or equivalent two-way communication facilities shall be maintained in good operating condition at all times. In the event of any failure in the system that results in loss of communication, repairs shall be started immediately, and the system restored to operating condition as soon as possible.\n\n[38 FR 29999, Oct. 31, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","heading":"Clamping of trailing cables to equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.605","part":"75","subchapter":"O","subpart":"G","id":"75.605","citation":"30 CFR 75.605","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519567","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}