{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519494","name":"No. 8","status":"Abandoned and Sealed","status_date":"2014-06-06","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Martin","nearest_town":"Debord","operator_id":"P15627","operator_name":"Coalburg Enterprises Inc.","controller_id":"C11194","controller_name":"James H  Booth","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.745,"longitude":-82.61},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":1377},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519494","name":"No. 8"},"operator":{"type":"operator","id":"P15627","name":"Coalburg Enterprises Inc."},"controller":{"type":"controller","id":"C11194","name":"James H  Booth"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"mine","id":"1519494","name":"No. 8"},"validFrom":"1984-04-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519494|C11194|1984-04-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P15627","name":"Coalburg Enterprises Inc."},"object":{"type":"mine","id":"1519494","name":"No. 8"},"validFrom":"2010-05-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519494|P15627|2010-05-25|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11194","name":"James H  Booth et al"},"object":{"type":"operator","id":"P15627","name":"Coalburg Enterprises Inc."},"validFrom":"2010-05-25","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519494","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519494|P15627|2010-05-25|C11194|1984-04-01|83865"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":16,"firstDate":"2010-07-16","lastDate":"2012-08-01","metrics":{"daysLost":258,"injuries":11,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"212356","DOCUMENT_NO":"220122260011","ACCIDENT_DT":"08/01/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee was loading roof bolts onto roof bolter when he picked up a hand full of bolts he twisted around and strained his back.","sourceDate":"2012-08-01"},{"SOURCE_ROW_NUMBER":"18780","DOCUMENT_NO":"220120690006","ACCIDENT_DT":"02/27/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall has occurred located 4 crosscuts U.G. inby from the surface. 3600' from the face. The fall was 20' in length 20' width and 6' in height. The fall will be cleaned up.","sourceDate":"2012-02-27"},{"SOURCE_ROW_NUMBER":"100341","DOCUMENT_NO":"220120270009","ACCIDENT_DT":"01/14/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by powered moving object","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"124","NARRATIVE":"Employee was standing next to a scoop when the scoop moved. It struck his left foot.","sourceDate":"2012-01-14"},{"SOURCE_ROW_NUMBER":"44549","DOCUMENT_NO":"220120270008","ACCIDENT_DT":"01/14/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was packing a bundle of roof bolt plates and he dropped them on his right foot bruising it on the side of his foot.","sourceDate":"2012-01-14"},{"SOURCE_ROW_NUMBER":"190753","DOCUMENT_NO":"220120030001","ACCIDENT_DT":"12/27/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall occurred in the No 1 return entry 270 ft outby the coal face. The fall was 20 ft long 30 ft wide and 7 ft thick. The fall will not be cleaned up. The entrance to fall is dangered off and supported as per roof control plan.","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"216722","DOCUMENT_NO":"220112620057","ACCIDENT_DT":"09/07/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof Fall 4,500 feet from face #4 entry. Fall was 6' in Height 18' in Width and 50' long. The fall will be cleaned up. Clean up plan is developed.","sourceDate":"2011-09-07"},{"SOURCE_ROW_NUMBER":"100340","DOCUMENT_NO":"220112550053","ACCIDENT_DT":"09/02/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"24","NARRATIVE":"Employee was roof bolting when a piece of draw rock fell and hit his right thumb when he was putting the drill still in the pot it fracture his right thumb.","sourceDate":"2011-09-02"},{"SOURCE_ROW_NUMBER":"61721","DOCUMENT_NO":"220112310037","ACCIDENT_DT":"08/11/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"25","NARRATIVE":"Employee was putting scoop on charge when he twisted his right knee.","sourceDate":"2011-08-11"},{"SOURCE_ROW_NUMBER":"61720","DOCUMENT_NO":"220112240049","ACCIDENT_DT":"08/02/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"43","NARRATIVE":"Employee was getting shuttle car loaded when shuttle bounced and his head hit the canopy of the shuttle car.","sourceDate":"2011-08-02"},{"SOURCE_ROW_NUMBER":"186551","DOCUMENT_NO":"220111890034","ACCIDENT_DT":"06/28/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"The fall was at survey station #317 in the #7 entry, 1800 ft from the face. The fall was 5 ft in height, 20 ft in width and 60 ft in length. The fall will not be cleaned up. The entrance to the fall is dangered off and supported as per roof control plan.","sourceDate":"2011-06-28"},{"SOURCE_ROW_NUMBER":"220979","DOCUMENT_NO":"220111290028","ACCIDENT_DT":"04/30/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall in #5 entry, 1 brake outby spad #313. 10'high 20'width 60' in length. Entrance to fall was dangered off and supported as per roof control plan and will not be cleaned up.","sourceDate":"2011-04-30"},{"SOURCE_ROW_NUMBER":"108869","DOCUMENT_NO":"220110980025","ACCIDENT_DT":"03/25/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cleaning out drill steel when he hit himself in the forehead with the drill steel cutting his forehead. He received 4 stitches.","sourceDate":"2011-03-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-06-06","lastDate":"2014-06-06","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":109,"firstDate":"2010-07-12","lastDate":"2012-06-14","metrics":{"ss":35,"delinquent":109,"recentRows":0,"paidPenalty":21978,"proposedPenalty":27130,"currentAssessment":21978},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1030777","VIOLATION_NO":"8251857","ISSUE_DT":"06/14/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"400.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1030776","VIOLATION_NO":"8251856","ISSUE_DT":"06/14/2012","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"400.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1030775","VIOLATION_NO":"8251855","ISSUE_DT":"06/14/2012","CFR_STANDARD_CD":"75.364(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1030801","VIOLATION_NO":"8271359","ISSUE_DT":"06/12/2012","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"350.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"1030800","VIOLATION_NO":"8271357","ISSUE_DT":"06/07/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"1030799","VIOLATION_NO":"8271356","ISSUE_DT":"06/07/2012","CFR_STANDARD_CD":"75.523-3(b)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"1030798","VIOLATION_NO":"8271355","ISSUE_DT":"06/07/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"1030797","VIOLATION_NO":"8271354","ISSUE_DT":"06/06/2012","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"1030779","VIOLATION_NO":"8270778","ISSUE_DT":"06/06/2012","CFR_STANDARD_CD":"75.1106-3(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"1030778","VIOLATION_NO":"8270770","ISSUE_DT":"06/06/2012","CFR_STANDARD_CD":"75.1103-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"1030796","VIOLATION_NO":"8271352","ISSUE_DT":"05/31/2012","CFR_STANDARD_CD":"75.362(d)(1)(iii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-31"},{"SOURCE_ROW_NUMBER":"1957989","VIOLATION_NO":"8263679","ISSUE_DT":"05/30/2012","CFR_STANDARD_CD":"75.211(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-30"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":56,"firstDate":"2011-07-12","lastDate":"2013-11-06","metrics":{"appeals":0,"decisions":56,"recentRows":0,"decisionPenalty":16661,"originalPenalty":21813},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"324295","VIOLATION_NO":"8270872","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"319.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"323887","VIOLATION_NO":"8270868","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"182.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"323752","VIOLATION_NO":"8270869","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"182.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"323751","VIOLATION_NO":"8270867","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"182.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"323693","VIOLATION_NO":"8270871","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"476.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"323692","VIOLATION_NO":"8263669","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"319.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"323525","VIOLATION_NO":"8270873","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"182.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"323524","VIOLATION_NO":"8244618","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"319.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"85770","VIOLATION_NO":"8270870","DOCKET_NO":"KENT 2012-902","DECISION_DT":"11/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"902.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-11-06"},{"SOURCE_ROW_NUMBER":"78540","VIOLATION_NO":"8251794","DOCKET_NO":"KENT 2012-47","DECISION_DT":"08/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"334.00","DECISION_PENALTY_AMT":"250.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2013-08-26"},{"SOURCE_ROW_NUMBER":"334202","VIOLATION_NO":"8251856","DOCKET_NO":"KENT 2013-96","DECISION_DT":"04/25/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2013-04-25"},{"SOURCE_ROW_NUMBER":"91915","VIOLATION_NO":"8251857","DOCKET_NO":"KENT 2013-96","DECISION_DT":"04/25/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"400.00","JUDGE_FIRST_NAME":"Janet","JUDGE_LAST_NAME":"Harner","sourceDate":"2013-04-25"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":162,"firstDate":"2010-08-03","lastDate":"2012-08-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":19,"validSamples":143,"maxConcentration":2.111,"concentrationTotal":59.584},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1631805","CASS_NUM":"57985775","SMP_TAKEN_DT":"8/14/2012","CONC":".215","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"1083906","CASS_NUM":"57985688","SMP_TAKEN_DT":"8/14/2012","CONC":".409","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (MOUNTED) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"1059563","CASS_NUM":"57985663","SMP_TAKEN_DT":"8/14/2012","CONC":".007","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"972769","CASS_NUM":"57985687","SMP_TAKEN_DT":"8/14/2012","CONC":".579","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"590796","CASS_NUM":"57985657","SMP_TAKEN_DT":"8/14/2012","CONC":".303","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"102658","CASS_NUM":"57985632","SMP_TAKEN_DT":"8/14/2012","CONC":".017","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"1033467","CASS_NUM":"51184902","SMP_TAKEN_DT":"8/10/2012","CONC":".073","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-08-10"},{"SOURCE_ROW_NUMBER":"1651564","CASS_NUM":"51184802","SMP_TAKEN_DT":"7/13/2012","CONC":".343","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-13"},{"SOURCE_ROW_NUMBER":"1267547","CASS_NUM":"51184825","SMP_TAKEN_DT":"7/12/2012","CONC":".178","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-12"},{"SOURCE_ROW_NUMBER":"482700","CASS_NUM":"51185217","SMP_TAKEN_DT":"7/12/2012","CONC":".253","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-12"},{"SOURCE_ROW_NUMBER":"1581401","CASS_NUM":"51185212","SMP_TAKEN_DT":"7/11/2012","CONC":".207","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-11"},{"SOURCE_ROW_NUMBER":"1016075","CASS_NUM":"51184776","SMP_TAKEN_DT":"7/11/2012","CONC":".175","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-07-11"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":56,"firstDate":"2010-07-12","lastDate":"2012-06-14","metrics":{"decisions":56,"ssChanged":2,"recentRows":0,"decisionPenalty":16661,"proposedPenalty":21813},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"309448","CITATION_NO":"8251857","CITATION_ISSUE_DT":"06/14/2012","DOCKET_NO":"KENT 2013-96","DECISION_DT":"04/25/2013","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"202189","CITATION_NO":"8251855","CITATION_ISSUE_DT":"06/14/2012","DOCKET_NO":"KENT 2012-1471","DECISION_DT":"01/24/2013","CFR_STANDARD_CODE":"75.364(h)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"85006","CITATION_NO":"8251856","CITATION_ISSUE_DT":"06/14/2012","DOCKET_NO":"KENT 2013-96","DECISION_DT":"04/25/2013","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"400.00","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"87285","CITATION_NO":"8271359","CITATION_ISSUE_DT":"06/12/2012","DOCKET_NO":"KENT 2012-1471","DECISION_DT":"01/24/2013","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"350.00","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"313383","CITATION_NO":"8271357","CITATION_ISSUE_DT":"06/07/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"311157","CITATION_NO":"8271355","CITATION_ISSUE_DT":"06/07/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"75.503","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"86614","CITATION_NO":"8271356","CITATION_ISSUE_DT":"06/07/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"75.523-3(b)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"634.00","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"426272","CITATION_NO":"8270778","CITATION_ISSUE_DT":"06/06/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"75.1106-3(a)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"634.00","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"141118","CITATION_NO":"8271354","CITATION_ISSUE_DT":"06/06/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"75.516","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"141117","CITATION_NO":"8270770","CITATION_ISSUE_DT":"06/06/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"75.1103-4(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"243.00","DECISION_PENALTY_AMT":"243.00","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"22390","CITATION_NO":"8271353","CITATION_ISSUE_DT":"06/05/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"70.207(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"199423","CITATION_NO":"8271352","CITATION_ISSUE_DT":"05/31/2012","DOCKET_NO":"KENT 2012-1353","DECISION_DT":"03/07/2013","CFR_STANDARD_CODE":"75.362(d)(1)(iii)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-05-31"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":670,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":110,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2010-05-25","lastDate":"2010-05-25","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":30,"firstDate":"2010-06-07","lastDate":"2012-08-10","metrics":{"inspectors":51,"recentRows":0,"onSiteHours":993.5,"inspectionHours":1542.25,"inspectionSamples":138},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"559694","EVENT_NO":"6388928","INSPECTION_BEGIN_DT":"08/10/2012","INSPECTION_END_DT":"09/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"40.5","SUM_TOTAL_ON_SITE_HOURS":"22.5","sourceDate":"2012-08-10"},{"SOURCE_ROW_NUMBER":"762542","EVENT_NO":"6392867","INSPECTION_BEGIN_DT":"07/06/2012","INSPECTION_END_DT":"07/06/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2012-07-06"},{"SOURCE_ROW_NUMBER":"84754","EVENT_NO":"6392860","INSPECTION_BEGIN_DT":"05/30/2012","INSPECTION_END_DT":"05/30/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-05-30"},{"SOURCE_ROW_NUMBER":"679701","EVENT_NO":"4191995","INSPECTION_BEGIN_DT":"04/04/2012","INSPECTION_END_DT":"06/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"176","SUM_TOTAL_ON_SITE_HOURS":"122.5","sourceDate":"2012-04-04"},{"SOURCE_ROW_NUMBER":"547765","EVENT_NO":"6389086","INSPECTION_BEGIN_DT":"03/14/2012","INSPECTION_END_DT":"03/14/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-03-14"},{"SOURCE_ROW_NUMBER":"1015192","EVENT_NO":"6389079","INSPECTION_BEGIN_DT":"02/27/2012","INSPECTION_END_DT":"03/05/2012","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2012-02-27"},{"SOURCE_ROW_NUMBER":"828462","EVENT_NO":"6392118","INSPECTION_BEGIN_DT":"01/25/2012","INSPECTION_END_DT":"01/25/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"932653","EVENT_NO":"6389307","INSPECTION_BEGIN_DT":"01/04/2012","INSPECTION_END_DT":"03/20/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"200.25","SUM_TOTAL_ON_SITE_HOURS":"125.75","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"960672","EVENT_NO":"6392104","INSPECTION_BEGIN_DT":"12/27/2011","INSPECTION_END_DT":"12/29/2011","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2011-12-27"},{"SOURCE_ROW_NUMBER":"904849","EVENT_NO":"6389076","INSPECTION_BEGIN_DT":"10/13/2011","INSPECTION_END_DT":"10/13/2011","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"476632","EVENT_NO":"6388450","INSPECTION_BEGIN_DT":"10/13/2011","INSPECTION_END_DT":"12/20/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"78","SUM_TOTAL_ON_SITE_HOURS":"53.5","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"343487","EVENT_NO":"6389068","INSPECTION_BEGIN_DT":"09/07/2011","INSPECTION_END_DT":"09/09/2011","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2011-09-07"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":18,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q3":{"hours":16043,"employees":35,"production":40924},"2012-Q2":{"hours":21561,"employees":37,"production":84890},"2012-Q1":{"hours":23737,"employees":32,"production":52732},"2011-Q4":{"hours":20122,"employees":35,"production":65682},"2011-Q3":{"hours":21787,"employees":34,"production":71755},"2011-Q2":{"hours":23321,"employees":33,"production":80062},"2011-Q1":{"hours":18312,"employees":31,"production":96931},"2010-Q4":{"hours":21395,"employees":31,"production":68477},"2010-Q3":{"hours":15249,"employees":30,"production":45547}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010":{"hours":36644,"employees":31,"production":114024},"2011":{"hours":83542,"employees":33,"production":314430},"2012":{"hours":61341,"employees":35,"production":178546}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2010-08-04","lastDate":"2012-01-14","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":783,"pelDoseTotal":521},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"106997","EVENT_NO":"6389307","SURVEY_DATE":"01/14/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"098","ACT_DOSE_85":"71","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2012-01-14"},{"SOURCE_ROW_NUMBER":"106996","EVENT_NO":"6389307","SURVEY_DATE":"01/14/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"62","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2012-01-14"},{"SOURCE_ROW_NUMBER":"106995","EVENT_NO":"6389307","SURVEY_DATE":"01/14/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"58","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2012-01-14"},{"SOURCE_ROW_NUMBER":"106994","EVENT_NO":"6389307","SURVEY_DATE":"01/14/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"48","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2012-01-14"},{"SOURCE_ROW_NUMBER":"106993","EVENT_NO":"6389307","SURVEY_DATE":"01/14/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"119","ACT_DOSE_85":"51","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2012-01-14"},{"SOURCE_ROW_NUMBER":"106992","EVENT_NO":"4192088","SURVEY_DATE":"11/03/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"015","ACT_DOSE_85":"66","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2010-11-03"},{"SOURCE_ROW_NUMBER":"106991","EVENT_NO":"4192088","SURVEY_DATE":"11/03/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2010-11-03"},{"SOURCE_ROW_NUMBER":"106990","EVENT_NO":"4192088","SURVEY_DATE":"11/03/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"44","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2010-11-03"},{"SOURCE_ROW_NUMBER":"106989","EVENT_NO":"4192088","SURVEY_DATE":"11/03/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"015","ACT_DOSE_85":"34","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2010-11-03"},{"SOURCE_ROW_NUMBER":"106988","EVENT_NO":"4192088","SURVEY_DATE":"11/03/2010","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"74","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2010-11-03"},{"SOURCE_ROW_NUMBER":"106987","EVENT_NO":"4192082","SURVEY_DATE":"08/04/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"067","ACT_DOSE_85":"53","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2010-08-04"},{"SOURCE_ROW_NUMBER":"106986","EVENT_NO":"4192082","SURVEY_DATE":"08/04/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"29","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2010-08-04"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":9,"firstDate":"2011-01-25","lastDate":"2011-11-19","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":6.7,"validSamples":7,"quartzPctTotal":23.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"11111","CASSETTE_NO":"57949871","SAMPLE_DT":"11/19/2011","QUARTZ_PCT":"00.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-19"},{"SOURCE_ROW_NUMBER":"95460","CASSETTE_NO":"57898480","SAMPLE_DT":"07/19/2011","QUARTZ_PCT":"02.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-07-19"},{"SOURCE_ROW_NUMBER":"61961","CASSETTE_NO":"57898507","SAMPLE_DT":"07/19/2011","QUARTZ_PCT":"00.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-07-19"},{"SOURCE_ROW_NUMBER":"81036","CASSETTE_NO":"51136856","SAMPLE_DT":"06/08/2011","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"OVERSIZE PARTICLES","sourceDate":"2011-06-08"},{"SOURCE_ROW_NUMBER":"40129","CASSETTE_NO":"51136859","SAMPLE_DT":"06/06/2011","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"OVERSIZE PARTICLES","sourceDate":"2011-06-06"},{"SOURCE_ROW_NUMBER":"109351","CASSETTE_NO":"51136841","SAMPLE_DT":"05/27/2011","QUARTZ_PCT":"02.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-27"},{"SOURCE_ROW_NUMBER":"129208","CASSETTE_NO":"57898624","SAMPLE_DT":"05/10/2011","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-10"},{"SOURCE_ROW_NUMBER":"74533","CASSETTE_NO":"57898642","SAMPLE_DT":"05/10/2011","QUARTZ_PCT":"06.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-10"},{"SOURCE_ROW_NUMBER":"46114","CASSETTE_NO":"57919528","SAMPLE_DT":"01/25/2011","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":117,"firstDate":"2010-07-12","lastDate":"2012-06-14","metrics":{"ss":35,"amountDue":21978,"contested":5,"amountPaid":21978,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":27130},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1173837","VIOLATION_NO":"8251857","VIOLATION_ISSUE_DT":"06/14/2012","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/15/2012","PROPOSED_PENALTY":"540","AMOUNT_DUE":"400","AMOUNT_PAID":"400","CONTESTED_IND":"N","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1173836","VIOLATION_NO":"8251856","VIOLATION_ISSUE_DT":"06/14/2012","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/15/2012","PROPOSED_PENALTY":"540","AMOUNT_DUE":"400","AMOUNT_PAID":"400","CONTESTED_IND":"N","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1173835","VIOLATION_NO":"8251855","VIOLATION_ISSUE_DT":"06/14/2012","SIG_SUB":"N","PART_SECTION":"75.364(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/14/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1173861","VIOLATION_NO":"8271359","VIOLATION_ISSUE_DT":"06/12/2012","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2012","PROPOSED_PENALTY":"634","AMOUNT_DUE":"350","AMOUNT_PAID":"350","CONTESTED_IND":"N","sourceDate":"2012-06-12"},{"SOURCE_ROW_NUMBER":"1173860","VIOLATION_NO":"8271357","VIOLATION_ISSUE_DT":"06/07/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"1173859","VIOLATION_NO":"8271356","VIOLATION_ISSUE_DT":"06/07/2012","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2012","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"634","CONTESTED_IND":"N","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"1173858","VIOLATION_NO":"8271355","VIOLATION_ISSUE_DT":"06/07/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/12/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"1173857","VIOLATION_NO":"8271354","VIOLATION_ISSUE_DT":"06/06/2012","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"1173839","VIOLATION_NO":"8270778","VIOLATION_ISSUE_DT":"06/06/2012","SIG_SUB":"Y","PART_SECTION":"75.1106-3(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/06/2012","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"634","CONTESTED_IND":"N","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"1173838","VIOLATION_NO":"8270770","VIOLATION_ISSUE_DT":"06/06/2012","SIG_SUB":"N","PART_SECTION":"75.1103-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/07/2012","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"243","CONTESTED_IND":"N","sourceDate":"2012-06-06"},{"SOURCE_ROW_NUMBER":"1173856","VIOLATION_NO":"8271352","VIOLATION_ISSUE_DT":"05/31/2012","SIG_SUB":"N","PART_SECTION":"75.362(d)(1)(iii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/31/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-05-31"},{"SOURCE_ROW_NUMBER":"1173865","VIOLATION_NO":"8263679","VIOLATION_ISSUE_DT":"05/30/2012","SIG_SUB":"N","PART_SECTION":"75.211(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/30/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-05-30"}]}],"safety":{"href":"/api/v1/mines/1519494/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519494/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1},{"chapter":"I","heading":"Roof testing and scaling.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.211","part":"75","subchapter":"O","subpart":"C","id":"75.211","citation":"30 CFR 75.211","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519494","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}