{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519438","name":"Mine #17","status":"Abandoned and Sealed","status_date":"2014-05-09","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Stopover","operator_id":"P23622","operator_name":"Blair Coal Co Inc.","controller_id":"C15524","controller_name":"Ricky  Blair","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.52,"longitude":-82.046389},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":252},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519438","name":"Mine #17"},"operator":{"type":"operator","id":"P23622","name":"Blair Coal Co Inc."},"controller":{"type":"controller","id":"C15524","name":"Ricky  Blair"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15524","name":"Ricky  Blair"},"object":{"type":"mine","id":"1519438","name":"Mine #17"},"validFrom":"1997-01-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519438|C15524|1997-01-28|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0077353","name":"Shelly B  Mullins et al"},"object":{"type":"mine","id":"1519438","name":"Mine #17"},"validFrom":"2008-07-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519438|0077353|2008-07-14|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0092165","name":"Appalachian Contractors Inc"},"object":{"type":"mine","id":"1519438","name":"Mine #17"},"validFrom":"2009-10-28","validTo":"2011-05-02","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519438|0092165|2009-10-28|2011-05-02"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0077353","name":"Shelly B  Mullins et al"},"object":{"type":"operator","id":"0092165","name":"Appalachian Contractors Inc"},"validFrom":"2009-10-28","validTo":"2011-05-02","current":false,"derived":true,"evidenceMineId":"1519438","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519438|0092165|2009-10-28|0077353|2008-07-14|12126"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23622","name":"Blair Coal Co Inc."},"object":{"type":"mine","id":"1519438","name":"Mine #17"},"validFrom":"2011-05-03","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519438|P23622|2011-05-03|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15524","name":"Ricky  Blair"},"object":{"type":"operator","id":"P23622","name":"Blair Coal Co Inc."},"validFrom":"2011-05-03","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519438","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519438|P23622|2011-05-03|C15524|1997-01-28|95824"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":2,"firstDate":"2011-10-24","lastDate":"2011-11-02","metrics":{"daysLost":156,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"143529","DOCUMENT_NO":"220113110027","ACCIDENT_DT":"11/02/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"101","NARRATIVE":"Employee was helping carry I beams, and pulled muscle in lower back","sourceDate":"2011-11-02"},{"SOURCE_ROW_NUMBER":"182259","DOCUMENT_NO":"220112980002","ACCIDENT_DT":"10/24/2011","DEGREE_INJURY":"PERM TOT OR PERM PRTL DISABLTY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"55","NARRATIVE":"Outside of the mine Putting Jack on Miner and dropped the jack on the tip of the left ring finger","sourceDate":"2011-10-24"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-05-09","lastDate":"2014-05-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":30,"firstDate":"2010-01-14","lastDate":"2012-10-23","metrics":{"ss":11,"delinquent":30,"recentRows":0,"paidPenalty":4117,"proposedPenalty":4117,"currentAssessment":4117},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1943321","VIOLATION_NO":"8260066","ISSUE_DT":"10/23/2012","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-23"},{"SOURCE_ROW_NUMBER":"1943320","VIOLATION_NO":"8260065","ISSUE_DT":"10/23/2012","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-23"},{"SOURCE_ROW_NUMBER":"1958014","VIOLATION_NO":"8269574","ISSUE_DT":"10/22/2012","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"1958015","VIOLATION_NO":"8274050","ISSUE_DT":"10/02/2012","CFR_STANDARD_CD":"70.100(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-02"},{"SOURCE_ROW_NUMBER":"1942446","VIOLATION_NO":"8273844","ISSUE_DT":"08/22/2012","CFR_STANDARD_CD":"70.201(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-22"},{"SOURCE_ROW_NUMBER":"1942445","VIOLATION_NO":"8273843","ISSUE_DT":"08/21/2012","CFR_STANDARD_CD":"72.630(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-21"},{"SOURCE_ROW_NUMBER":"1942444","VIOLATION_NO":"8269504","ISSUE_DT":"07/26/2012","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-26"},{"SOURCE_ROW_NUMBER":"1942443","VIOLATION_NO":"8269503","ISSUE_DT":"07/18/2012","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"1942442","VIOLATION_NO":"8269502","ISSUE_DT":"07/18/2012","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"1942441","VIOLATION_NO":"8269501","ISSUE_DT":"07/16/2012","CFR_STANDARD_CD":"75.203(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-16"},{"SOURCE_ROW_NUMBER":"1942440","VIOLATION_NO":"8269500","ISSUE_DT":"07/16/2012","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-07-16"},{"SOURCE_ROW_NUMBER":"1941584","VIOLATION_NO":"8268921","ISSUE_DT":"04/25/2012","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-04-25"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":104,"firstDate":"2011-10-19","lastDate":"2012-11-08","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":21,"validSamples":83,"maxConcentration":10.719,"concentrationTotal":88.053},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1091767","CASS_NUM":"51214185","SMP_TAKEN_DT":"11/8/2012","CONC":"1.887","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-08"},{"SOURCE_ROW_NUMBER":"727801","CASS_NUM":"51214086","SMP_TAKEN_DT":"11/7/2012","CONC":"1.446","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-11-07"},{"SOURCE_ROW_NUMBER":"66894","CASS_NUM":"51214189","SMP_TAKEN_DT":"10/25/2012","CONC":".324","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-25"},{"SOURCE_ROW_NUMBER":"994927","CASS_NUM":"51198021","SMP_TAKEN_DT":"10/24/2012","CONC":"1.062","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-24"},{"SOURCE_ROW_NUMBER":"1212584","CASS_NUM":"51196215","SMP_TAKEN_DT":"10/23/2012","CONC":".855","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-23"},{"SOURCE_ROW_NUMBER":"966317","CASS_NUM":"51198243","SMP_TAKEN_DT":"10/22/2012","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"BROKEN","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"180891","CASS_NUM":"51198217","SMP_TAKEN_DT":"10/22/2012","CONC":"1.423","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"1501414","CASS_NUM":"51202291","SMP_TAKEN_DT":"10/19/2012","CONC":"1.04","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"466540","CASS_NUM":"51196189","SMP_TAKEN_DT":"10/19/2012","CONC":".086","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-19"},{"SOURCE_ROW_NUMBER":"310140","CASS_NUM":"51202298","SMP_TAKEN_DT":"10/15/2012","CONC":".202","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-15"},{"SOURCE_ROW_NUMBER":"1344299","CASS_NUM":"51198220","SMP_TAKEN_DT":"10/2/2012","CONC":".517","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-02"},{"SOURCE_ROW_NUMBER":"1164240","CASS_NUM":"51198225","SMP_TAKEN_DT":"10/1/2012","CONC":".099","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-10-01"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2009-10-28","lastDate":"2011-05-03","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":31,"firstDate":"2009-11-06","lastDate":"2013-02-06","metrics":{"inspectors":49,"recentRows":0,"onSiteHours":483,"inspectionHours":873.5,"inspectionSamples":65},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1128933","EVENT_NO":"6381862","INSPECTION_BEGIN_DT":"02/06/2013","INSPECTION_END_DT":"02/06/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2013-02-06"},{"SOURCE_ROW_NUMBER":"175317","EVENT_NO":"4203579","INSPECTION_BEGIN_DT":"01/22/2013","INSPECTION_END_DT":"01/22/2013","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2013-01-22"},{"SOURCE_ROW_NUMBER":"579072","EVENT_NO":"4195722","INSPECTION_BEGIN_DT":"10/15/2012","INSPECTION_END_DT":"10/18/2012","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2012-10-15"},{"SOURCE_ROW_NUMBER":"495585","EVENT_NO":"6381851","INSPECTION_BEGIN_DT":"10/10/2012","INSPECTION_END_DT":"12/20/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"67.5","SUM_TOTAL_ON_SITE_HOURS":"38.75","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"1068697","EVENT_NO":"6392905","INSPECTION_BEGIN_DT":"10/02/2012","INSPECTION_END_DT":"11/15/2012","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"51.5","SUM_TOTAL_ON_SITE_HOURS":"29.5","sourceDate":"2012-10-02"},{"SOURCE_ROW_NUMBER":"986448","EVENT_NO":"4203799","INSPECTION_BEGIN_DT":"08/14/2012","INSPECTION_END_DT":"08/14/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-08-14"},{"SOURCE_ROW_NUMBER":"851829","EVENT_NO":"6381653","INSPECTION_BEGIN_DT":"07/03/2012","INSPECTION_END_DT":"08/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"154","SUM_TOTAL_ON_SITE_HOURS":"97.5","sourceDate":"2012-07-03"},{"SOURCE_ROW_NUMBER":"166931","EVENT_NO":"4173930","INSPECTION_BEGIN_DT":"06/11/2012","INSPECTION_END_DT":"06/11/2012","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"548705","EVENT_NO":"4173929","INSPECTION_BEGIN_DT":"06/07/2012","INSPECTION_END_DT":"06/08/2012","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"17.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"848439","EVENT_NO":"6381483","INSPECTION_BEGIN_DT":"04/02/2012","INSPECTION_END_DT":"04/30/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"63.5","SUM_TOTAL_ON_SITE_HOURS":"43.5","sourceDate":"2012-04-02"},{"SOURCE_ROW_NUMBER":"1102702","EVENT_NO":"4203730","INSPECTION_BEGIN_DT":"03/29/2012","INSPECTION_END_DT":"03/29/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2012-03-29"},{"SOURCE_ROW_NUMBER":"151164","EVENT_NO":"4203630","INSPECTION_BEGIN_DT":"01/10/2012","INSPECTION_END_DT":"01/11/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2012-01-10"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":36,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014-Q1":{"hours":0,"employees":0,"production":0},"2013-Q4":{"hours":0,"employees":0,"production":0},"2013-Q3":{"hours":0,"employees":0,"production":0},"2013-Q2":{"hours":0,"employees":0,"production":0},"2013-Q1":{"hours":0,"employees":0,"production":0},"2012-Q4":{"hours":2957,"employees":15,"production":2301},"2012-Q3":{"hours":5081,"employees":12,"production":4612},"2012-Q2":{"hours":5942,"employees":15,"production":8031},"2012-Q1":{"hours":4971,"employees":11,"production":6088},"2011-Q4":{"hours":4283,"employees":11,"production":3116},"2011-Q3":{"hours":2986,"employees":9,"production":539},"2011-Q2":{"hours":1174,"employees":6,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010":{"hours":3479,"employees":7,"production":538},"2011":{"hours":8443,"employees":9,"production":3655},"2012":{"hours":18951,"employees":13,"production":21032}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":7,"firstDate":"2012-01-10","lastDate":"2012-01-12","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":190,"pelDoseTotal":125},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"106077","EVENT_NO":"6381186","SURVEY_DATE":"01/12/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2012-01-12"},{"SOURCE_ROW_NUMBER":"106076","EVENT_NO":"6381186","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"72","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"106075","EVENT_NO":"6381186","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"20","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"106074","EVENT_NO":"6381186","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"25","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"106073","EVENT_NO":"6381186","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"21","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"106072","EVENT_NO":"6381186","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"STOPPING BUILDER/VENTILATION MAN/MASON","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"38","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2012-01-10"},{"SOURCE_ROW_NUMBER":"106071","EVENT_NO":"6381186","SURVEY_DATE":"01/10/2012","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"12","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2012-01-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":1,"firstDate":"2012-01-10","lastDate":"2012-01-10","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.1,"validSamples":1,"quartzPctTotal":6.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"140782","CASSETTE_NO":"57889459","SAMPLE_DT":"01/10/2012","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":32,"firstDate":"2010-01-14","lastDate":"2012-10-23","metrics":{"ss":11,"amountDue":4117,"contested":0,"amountPaid":4117,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":4117},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1170496","VIOLATION_NO":"8260066","VIOLATION_ISSUE_DT":"10/23/2012","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/23/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-23"},{"SOURCE_ROW_NUMBER":"1170495","VIOLATION_NO":"8260065","VIOLATION_ISSUE_DT":"10/23/2012","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/23/2012","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2012-10-23"},{"SOURCE_ROW_NUMBER":"1170484","VIOLATION_NO":"8269574","VIOLATION_ISSUE_DT":"10/22/2012","SIG_SUB":"N","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/22/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-22"},{"SOURCE_ROW_NUMBER":"1170485","VIOLATION_NO":"8274050","VIOLATION_ISSUE_DT":"10/02/2012","SIG_SUB":"Y","PART_SECTION":"70.100(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/15/2012","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"224","CONTESTED_IND":"N","sourceDate":"2012-10-02"},{"SOURCE_ROW_NUMBER":"1170482","VIOLATION_NO":"8273844","VIOLATION_ISSUE_DT":"08/22/2012","SIG_SUB":"N","PART_SECTION":"70.201(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/23/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-22"},{"SOURCE_ROW_NUMBER":"1170481","VIOLATION_NO":"8273843","VIOLATION_ISSUE_DT":"08/21/2012","SIG_SUB":"Y","PART_SECTION":"72.630(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/23/2012","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2012-08-21"},{"SOURCE_ROW_NUMBER":"1170480","VIOLATION_NO":"8269504","VIOLATION_ISSUE_DT":"07/26/2012","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-26"},{"SOURCE_ROW_NUMBER":"1170479","VIOLATION_NO":"8269503","VIOLATION_ISSUE_DT":"07/18/2012","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/18/2012","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"1170478","VIOLATION_NO":"8269502","VIOLATION_ISSUE_DT":"07/18/2012","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/20/2012","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2012-07-18"},{"SOURCE_ROW_NUMBER":"1170477","VIOLATION_NO":"8269501","VIOLATION_ISSUE_DT":"07/16/2012","SIG_SUB":"N","PART_SECTION":"75.203(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/16/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-16"},{"SOURCE_ROW_NUMBER":"1170476","VIOLATION_NO":"8269500","VIOLATION_ISSUE_DT":"07/16/2012","SIG_SUB":"N","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/16/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-07-16"},{"SOURCE_ROW_NUMBER":"1170474","VIOLATION_NO":"8268921","VIOLATION_ISSUE_DT":"04/25/2012","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/25/2012","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2012-04-25"}]}],"safety":{"href":"/api/v1/mines/1519438/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519438/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":3},{"chapter":"I","heading":"Respirable dust standards.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-B/section-70.100","part":"70","subchapter":"O","subpart":"B","id":"70.100","citation":"30 CFR 70.100","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Sampling; general and technical requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.201","part":"70","subchapter":"O","subpart":"C","id":"70.201","citation":"30 CFR 70.201","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","heading":"Mining methods.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.203","part":"75","subchapter":"O","subpart":"C","id":"75.203","citation":"30 CFR 75.203","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519438","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}