{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-17T06:17:15.228Z","identity":{"mine_id":"1519424","name":"Riveredge Mine","status":"Abandoned","status_date":"2019-11-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Mclean","nearest_town":"Calhoun, Kentucky","operator_id":"0136993","operator_name":"Rough Creek Mining, LLC","controller_id":"C15455","controller_name":"Alliance Resource Partners LP","district":"C10","office":"Madisonville KY Field Office","employees":0,"latitude":37.636667,"longitude":-87.44},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":12507},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-17T05:35:58.500035+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"operator":{"type":"operator","id":"0136993","name":"Rough Creek Mining, LLC"},"controller":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-17T05:35:58.500035+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0103125","name":"West Kentucky Energy Company"},"object":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"validFrom":"2009-08-07","validTo":"2012-05-01","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0103125|2009-08-07|2012-05-01"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"validFrom":"2009-08-07","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|C02508|2009-08-07|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"0103125","name":"West Kentucky Energy Company"},"validFrom":"2009-08-07","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1519424","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0103125|2009-08-07|C02508|2009-08-07|59563"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"0103125","name":"West Kentucky Energy Company"},"validFrom":"2011-06-01","validTo":"2012-05-01","current":false,"derived":true,"evidenceMineId":"1519424","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0103125|2009-08-07|0041211|2011-06-01|2263"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0122770","name":"Pennyrile Energy LLC"},"object":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"validFrom":"2012-05-02","validTo":"2020-04-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0122770|2012-05-02|2020-04-12"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"validFrom":"2012-05-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0098293|2012-05-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"operator","id":"0122770","name":"Pennyrile Energy LLC"},"validFrom":"2012-05-02","validTo":"2020-04-12","current":false,"derived":true,"evidenceMineId":"1519424","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0122770|2012-05-02|0098293|2012-05-02|16168"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"validFrom":"2015-02-03","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|C15455|2015-02-03|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0136993","name":"Rough Creek Mining, LLC"},"object":{"type":"mine","id":"1519424","name":"Riveredge Mine"},"validFrom":"2020-04-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0136993|2020-04-13|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15455","name":"Alliance Resource Partners LP"},"object":{"type":"operator","id":"0136993","name":"Rough Creek Mining, LLC"},"validFrom":"2020-04-13","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519424","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-17T05:35:58.500035+00:00","recordKey":"1519424|0136993|2020-04-13|C15455|2015-02-03|95708"}}],"coverage":{"historyRecords":4,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":72,"firstDate":"2013-10-02","lastDate":"2019-10-17","metrics":{"daysLost":2022,"injuries":70,"fatalities":0,"recentRows":0,"restrictedDays":116,"contractorRecords":6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"156455","DOCUMENT_NO":"220192940004","ACCIDENT_DT":"10/17/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"11","NARRATIVE":"While dragging a 480 VAC pump cathead and cable to a ride, EE slipped in the mud initially claiming to have \"popped\" EE's left knee but later claimed to have strained EE's lower back resulting in significant pain.","sourceDate":"2019-10-17"},{"SOURCE_ROW_NUMBER":"194994","DOCUMENT_NO":"220192600017","ACCIDENT_DT":"09/13/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee stated that while coming out of the mine they pushed airlock door open and large amount of dust blew up under glasses filling their eyes up. Employee was treated and released w/medicated eye drops.","sourceDate":"2019-09-13"},{"SOURCE_ROW_NUMBER":"173608","DOCUMENT_NO":"220192380025","ACCIDENT_DT":"08/20/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"52","NARRATIVE":"Employee states they were double booming a six foot glue bolt and while bending roof bolt straight to install it rolled out and caused them to lose balance, hyper extending their left arm causing pain from bicep to shoulder in elbow area.","sourceDate":"2019-08-20"},{"SOURCE_ROW_NUMBER":"268255","DOCUMENT_NO":"220191770008","ACCIDENT_DT":"06/20/2019","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee states while working under #4 shuttle car on #2 unit a large amount of material fell on EE (coal, Dirt) fell landing in EE's eyes and in EE's left ear. Took employee to ER at Baptist health in Madisonville and received antibiotic eye drops. Employee back to work next shift.","sourceDate":"2019-06-20"},{"SOURCE_ROW_NUMBER":"104532","DOCUMENT_NO":"220190220022","ACCIDENT_DT":"01/09/2019","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"122","NARRATIVE":"1-17-19 Employee stated ee fell over miner cable or miner pull strap on #2 unit on 1-9-2019 stated didn't report to supervisor thought it would be fine. 17th ee reported and we took ee for medical attention, released no restrictions! 1-21-19 I sent ee back to Dr. ee states ee was having trouble 1-22-19 is the first lost day of the incident.","sourceDate":"2019-01-09"},{"SOURCE_ROW_NUMBER":"18778","DOCUMENT_NO":"220182600008","ACCIDENT_DT":"09/15/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Section foreman, Bullgang foreman, Labor foreman, Leadman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee tightening a ratchet strap securing a slinger duster and hook came loose striking EE in the mouth breaking a tooth in middle top of EE's mouth and loosening three more.","sourceDate":"2018-09-15"},{"SOURCE_ROW_NUMBER":"31735","DOCUMENT_NO":"220182430042","ACCIDENT_DT":"08/29/2018","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Rock fall in-by the tail piece on #2 unit in the #7 entry in the 2nd east sub mains.","sourceDate":"2018-08-29"},{"SOURCE_ROW_NUMBER":"220980","DOCUMENT_NO":"220182150004","ACCIDENT_DT":"07/31/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee attempting to remove shuttle car tire with another employee, the tire came off before they thought and caught left hand between tire and frame. After examination found chip fracture in top of hand.","sourceDate":"2018-07-31"},{"SOURCE_ROW_NUMBER":"108864","DOCUMENT_NO":"220181760013","ACCIDENT_DT":"06/18/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"106","NARRATIVE":"Employee states while traveling back to the Cont. Miner to get a load of coal on #1 unit and between entries 6 and 7 drove over a large rock causing them to bounce into the canopy hurting their upper back. Employee worked the next shift and went to doctor and is now off until next appointment.","sourceDate":"2018-06-18"},{"SOURCE_ROW_NUMBER":"74625","DOCUMENT_NO":"220181520026","ACCIDENT_DT":"05/23/2018","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"IE beating dust out of pinner steels with a 1' wrench when wrench bounced back and hit IE in forehead resulting in laceration needing 3 sutures to close.","sourceDate":"2018-05-23"},{"SOURCE_ROW_NUMBER":"208043","DOCUMENT_NO":"220181420021","ACCIDENT_DT":"05/17/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Flash burns (welding)","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"Employee welding on #1 unit golf card, holding metal and didn't get assistance or use welding hood that was provided.","sourceDate":"2018-05-17"},{"SOURCE_ROW_NUMBER":"100334","DOCUMENT_NO":"220181230027","ACCIDENT_DT":"04/27/2018","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"48","NARRATIVE":"Employee states while moving miner cable on #2 unit stepped in hole of mine floor twisting and straining left calf muscle. Finished shift and returned to work next day, did not become lost time until 5-1-2018.","sourceDate":"2018-04-27"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2019-11-01","lastDate":"2019-11-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1352,"firstDate":"2011-02-01","lastDate":"2019-10-10","metrics":{"ss":319,"delinquent":1099,"recentRows":0,"paidPenalty":688762,"proposedPenalty":813411,"currentAssessment":688762},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"2041790","VIOLATION_NO":"9144897","ISSUE_DT":"10/10/2019","CFR_STANDARD_CD":"75.1600-3(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-10-10"},{"SOURCE_ROW_NUMBER":"2040689","VIOLATION_NO":"9149257","ISSUE_DT":"09/05/2019","CFR_STANDARD_CD":"75.1909(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-09-05"},{"SOURCE_ROW_NUMBER":"2040701","VIOLATION_NO":"9149441","ISSUE_DT":"08/30/2019","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-30"},{"SOURCE_ROW_NUMBER":"2040700","VIOLATION_NO":"9149420","ISSUE_DT":"08/29/2019","CFR_STANDARD_CD":"75.1914(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"270.00","CURRENT_ASSESSMENT_AMT":"270.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2040699","VIOLATION_NO":"9149419","ISSUE_DT":"08/29/2019","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2040698","VIOLATION_NO":"9149418","ISSUE_DT":"08/29/2019","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"2353.00","CURRENT_ASSESSMENT_AMT":"2353.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2040697","VIOLATION_NO":"9149417","ISSUE_DT":"08/29/2019","CFR_STANDARD_CD":"75.1911(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"230.00","CURRENT_ASSESSMENT_AMT":"230.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2040688","VIOLATION_NO":"9149256","ISSUE_DT":"08/29/2019","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2040687","VIOLATION_NO":"9149254","ISSUE_DT":"08/28/2019","CFR_STANDARD_CD":"48.9(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-28"},{"SOURCE_ROW_NUMBER":"2040686","VIOLATION_NO":"9149253","ISSUE_DT":"08/28/2019","CFR_STANDARD_CD":"75.204(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"121.00","CURRENT_ASSESSMENT_AMT":"121.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-28"},{"SOURCE_ROW_NUMBER":"2040685","VIOLATION_NO":"9149252","ISSUE_DT":"08/27/2019","CFR_STANDARD_CD":"75.350(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"214.00","CURRENT_ASSESSMENT_AMT":"214.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"2040684","VIOLATION_NO":"9149251","ISSUE_DT":"08/27/2019","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"977.00","CURRENT_ASSESSMENT_AMT":"350.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2019-08-27"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":125,"firstDate":"2015-03-16","lastDate":"2020-02-11","metrics":{"appeals":0,"decisions":125,"recentRows":0,"decisionPenalty":213919,"originalPenalty":344310},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"189506","VIOLATION_NO":"9149251","DOCKET_NO":"KENT 2020-0026","DECISION_DT":"02/11/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"977.00","DECISION_PENALTY_AMT":"350.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-02-11"},{"SOURCE_ROW_NUMBER":"189164","VIOLATION_NO":"9149257","DOCKET_NO":"KENT 2020-0026","DECISION_DT":"02/11/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-02-11"},{"SOURCE_ROW_NUMBER":"431124","VIOLATION_NO":"9149420","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431123","VIOLATION_NO":"9149418","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2353.00","DECISION_PENALTY_AMT":"2353.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431122","VIOLATION_NO":"9149417","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"230.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431121","VIOLATION_NO":"9149410","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"708.00","DECISION_PENALTY_AMT":"708.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431120","VIOLATION_NO":"9149283","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"440.00","DECISION_PENALTY_AMT":"218.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431119","VIOLATION_NO":"9149256","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431118","VIOLATION_NO":"9149246","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431117","VIOLATION_NO":"9149033","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"154.00","DECISION_PENALTY_AMT":"154.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431011","VIOLATION_NO":"9149419","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"},{"SOURCE_ROW_NUMBER":"431010","VIOLATION_NO":"9149254","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2020-01-21"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":4971,"firstDate":"2014-06-11","lastDate":"2019-09-16","metrics":{"recentRows":0,"cpdmSamples":4011,"voidSamples":815,"validSamples":4156,"maxConcentration":32.517,"concentrationTotal":4097.68},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1640254","CASS_NUM":"58319127","SMP_TAKEN_DT":"9/16/2019","CONC":".14","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-09-16"},{"SOURCE_ROW_NUMBER":"1292596","CASS_NUM":"58318847","SMP_TAKEN_DT":"9/16/2019","CONC":".041","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-09-16"},{"SOURCE_ROW_NUMBER":"259777","CASS_NUM":"58319131","SMP_TAKEN_DT":"9/16/2019","CONC":"0","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"BROKEN","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2019-09-16"},{"SOURCE_ROW_NUMBER":"2808777","SMP_TAKEN_DT":"8/29/2019","CONC":".544","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2807849","SMP_TAKEN_DT":"8/29/2019","CONC":".506","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2807848","SMP_TAKEN_DT":"8/29/2019","CONC":".756","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2722191","SMP_TAKEN_DT":"8/29/2019","CONC":"1.06","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2722190","SMP_TAKEN_DT":"8/29/2019","CONC":".7","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2466616","SMP_TAKEN_DT":"8/29/2019","CONC":".46","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2039017","SMP_TAKEN_DT":"8/29/2019","CONC":".426","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"2978941","SMP_TAKEN_DT":"8/28/2019","CONC":".861","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-28"},{"SOURCE_ROW_NUMBER":"2808201","SMP_TAKEN_DT":"8/28/2019","CONC":".909","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2019-08-28"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":85,"firstDate":"2013-08-27","lastDate":"2019-09-27","metrics":{"linkedIssuances":85},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":125,"firstDate":"2014-02-22","lastDate":"2019-09-05","metrics":{"decisions":125,"ssChanged":18,"recentRows":0,"decisionPenalty":213919,"proposedPenalty":344310},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"102903","CITATION_NO":"9149257","CITATION_ISSUE_DT":"09/05/2019","DOCKET_NO":"KENT 2020-0026","DECISION_DT":"02/11/2020","CFR_STANDARD_CODE":"75.1909(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-09-05"},{"SOURCE_ROW_NUMBER":"158858","CITATION_NO":"9149441","CITATION_ISSUE_DT":"08/30/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.403","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-08-30"},{"SOURCE_ROW_NUMBER":"443804","CITATION_NO":"9149417","CITATION_ISSUE_DT":"08/29/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.1911(i)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"230.00","DECISION_PENALTY_AMT":"230.00","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"385710","CITATION_NO":"9149420","CITATION_ISSUE_DT":"08/29/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.1914(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"270.00","DECISION_PENALTY_AMT":"270.00","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"385388","CITATION_NO":"9149256","CITATION_ISSUE_DT":"08/29/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"385083","CITATION_NO":"9149418","CITATION_ISSUE_DT":"08/29/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2353.00","DECISION_PENALTY_AMT":"2353.00","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"215660","CITATION_NO":"9149419","CITATION_ISSUE_DT":"08/29/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"442063","CITATION_NO":"9149253","CITATION_ISSUE_DT":"08/28/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.204(c)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"121.00","DECISION_PENALTY_AMT":"121.00","sourceDate":"2019-08-28"},{"SOURCE_ROW_NUMBER":"102803","CITATION_NO":"9149254","CITATION_ISSUE_DT":"08/28/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"48.9(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","sourceDate":"2019-08-28"},{"SOURCE_ROW_NUMBER":"103141","CITATION_NO":"9149252","CITATION_ISSUE_DT":"08/27/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.350(a)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"214.00","DECISION_PENALTY_AMT":"214.00","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"102162","CITATION_NO":"9149251","CITATION_ISSUE_DT":"08/27/2019","DOCKET_NO":"KENT 2020-0026","DECISION_DT":"02/11/2020","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"977.00","DECISION_PENALTY_AMT":"350.00","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"441995","CITATION_NO":"9149410","CITATION_ISSUE_DT":"08/26/2019","DOCKET_NO":"KENT 2020-0017","DECISION_DT":"01/21/2020","CFR_STANDARD_CODE":"75.1107-16(c)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"708.00","DECISION_PENALTY_AMT":"708.00","sourceDate":"2019-08-26"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":3119,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":13,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":686,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":13,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2009-08-07","lastDate":"2020-04-13","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":104,"firstDate":"2010-03-03","lastDate":"2019-10-01","metrics":{"inspectors":576,"recentRows":0,"onSiteHours":11714.25,"inspectionHours":18148.5,"inspectionSamples":2159},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"473047","EVENT_NO":"6485488","INSPECTION_BEGIN_DT":"10/01/2019","INSPECTION_END_DT":"12/12/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"11","SUM_TOTAL_INSP_HOURS":"249","SUM_TOTAL_ON_SITE_HOURS":"141.75","sourceDate":"2019-10-01"},{"SOURCE_ROW_NUMBER":"920072","EVENT_NO":"6485827","INSPECTION_BEGIN_DT":"09/16/2019","INSPECTION_END_DT":"09/16/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2019-09-16"},{"SOURCE_ROW_NUMBER":"621043","EVENT_NO":"6485353","INSPECTION_BEGIN_DT":"08/02/2019","INSPECTION_END_DT":"08/09/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2019-08-02"},{"SOURCE_ROW_NUMBER":"474533","EVENT_NO":"6484558","INSPECTION_BEGIN_DT":"07/22/2019","INSPECTION_END_DT":"07/22/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2019-07-22"},{"SOURCE_ROW_NUMBER":"818599","EVENT_NO":"6485269","INSPECTION_BEGIN_DT":"07/01/2019","INSPECTION_END_DT":"09/24/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"20","SUM_TOTAL_INSP_HOURS":"803.25","SUM_TOTAL_ON_SITE_HOURS":"550.5","sourceDate":"2019-07-01"},{"SOURCE_ROW_NUMBER":"125842","EVENT_NO":"6484556","INSPECTION_BEGIN_DT":"06/26/2019","INSPECTION_END_DT":"06/26/2019","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.25","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2019-06-26"},{"SOURCE_ROW_NUMBER":"1042130","EVENT_NO":"6484776","INSPECTION_BEGIN_DT":"06/24/2019","INSPECTION_END_DT":"06/25/2019","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"36.5","SUM_TOTAL_ON_SITE_HOURS":"25.5","sourceDate":"2019-06-24"},{"SOURCE_ROW_NUMBER":"1070862","EVENT_NO":"6484775","INSPECTION_BEGIN_DT":"05/31/2019","INSPECTION_END_DT":"05/31/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2019-05-31"},{"SOURCE_ROW_NUMBER":"542043","EVENT_NO":"6484737","INSPECTION_BEGIN_DT":"05/15/2019","INSPECTION_END_DT":"05/15/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"19.25","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2019-05-15"},{"SOURCE_ROW_NUMBER":"1154686","EVENT_NO":"6484736","INSPECTION_BEGIN_DT":"05/12/2019","INSPECTION_END_DT":"05/13/2019","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2019-05-12"},{"SOURCE_ROW_NUMBER":"171294","EVENT_NO":"4490950","INSPECTION_BEGIN_DT":"05/02/2019","INSPECTION_END_DT":"05/02/2019","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2019-05-02"},{"SOURCE_ROW_NUMBER":"236164","EVENT_NO":"6484773","INSPECTION_BEGIN_DT":"04/01/2019","INSPECTION_END_DT":"06/26/2019","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"16","SUM_TOTAL_INSP_HOURS":"930.75","SUM_TOTAL_ON_SITE_HOURS":"652.75","sourceDate":"2019-04-01"}]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":22,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013":{"hours":10816,"employees":16,"production":0},"2014":{"hours":127066,"employees":61,"production":220910},"2015":{"hours":274779,"employees":115,"production":842924},"2016":{"hours":379058,"employees":149,"production":1274873},"2017":{"hours":370186,"employees":138,"production":1313001},"2018":{"hours":388675,"employees":142,"production":1270993},"2019":{"hours":330072,"employees":128,"production":876778}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":198,"firstDate":"2014-06-23","lastDate":"2019-09-17","metrics":{"recentRows":0,"doseOver100":45,"actDoseTotal":13250,"pelDoseTotal":10091},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"105761","EVENT_NO":"6485269","SURVEY_DATE":"09/17/2019","OCCUPATION_CD_DESC":"SAFETY DIRECTOR","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"0","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2019-09-17"},{"SOURCE_ROW_NUMBER":"105760","EVENT_NO":"6485269","SURVEY_DATE":"09/17/2019","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"017","ACT_DOSE_85":"22","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2019-09-17"},{"SOURCE_ROW_NUMBER":"105759","EVENT_NO":"6485269","SURVEY_DATE":"09/17/2019","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"20","MANUFACTURER_CD":"119","ACT_DOSE_85":"1","PEL_DOSE_90":"0","SURVEY_TYPE":"I","sourceDate":"2019-09-17"},{"SOURCE_ROW_NUMBER":"105758","EVENT_NO":"6485269","SURVEY_DATE":"09/17/2019","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"1","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2019-09-17"},{"SOURCE_ROW_NUMBER":"105581","EVENT_NO":"4488440","SURVEY_DATE":"03/26/2019","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2019-03-26"},{"SOURCE_ROW_NUMBER":"105580","EVENT_NO":"4488440","SURVEY_DATE":"03/26/2019","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"4","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2019-03-26"},{"SOURCE_ROW_NUMBER":"105579","EVENT_NO":"4488440","SURVEY_DATE":"03/26/2019","OCCUPATION_CD_DESC":"FORKLIFT OPERATOR","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"16","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2019-03-26"},{"SOURCE_ROW_NUMBER":"105578","EVENT_NO":"4488440","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"104","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"105577","EVENT_NO":"4488440","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"82","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"105576","EVENT_NO":"4488440","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"105575","EVENT_NO":"4488440","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"73","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2019-03-19"},{"SOURCE_ROW_NUMBER":"105574","EVENT_NO":"4488440","SURVEY_DATE":"03/19/2019","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"130","PEL_DOSE_90":"115","SURVEY_TYPE":"I","sourceDate":"2019-03-19"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":279,"firstDate":"2014-08-04","lastDate":"2019-08-27","metrics":{"recentRows":0,"voidSamples":45,"maxQuartzPct":4,"validSamples":234,"quartzPctTotal":440.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"128473","CASSETTE_NO":"58317486","SAMPLE_DT":"08/27/2019","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"93948","CASSETTE_NO":"58317410","SAMPLE_DT":"08/27/2019","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"91406","CASSETTE_NO":"58317407","SAMPLE_DT":"08/27/2019","QUARTZ_PCT":"01.2","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"24519","CASSETTE_NO":"58317413","SAMPLE_DT":"08/27/2019","QUARTZ_PCT":"01.5","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"15799","CASSETTE_NO":"58317405","SAMPLE_DT":"08/27/2019","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-08-27"},{"SOURCE_ROW_NUMBER":"115165","CASSETTE_NO":"58321175","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"00.5","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"112780","CASSETTE_NO":"58321531","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"02.6","QUARTZ_MICROGRAMS":"32","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"68610","CASSETTE_NO":"58321443","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"00.4","QUARTZ_MICROGRAMS":"3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"58576","CASSETTE_NO":"58321157","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"00.3","QUARTZ_MICROGRAMS":"2","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"38406","CASSETTE_NO":"58321350","SAMPLE_DT":"07/17/2019","QUARTZ_PCT":"00.8","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"10651","CASSETTE_NO":"58321235","SAMPLE_DT":"07/17/2019","QUARTZ_MICROGRAMS":"0","OCC_CODE_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-17"},{"SOURCE_ROW_NUMBER":"132799","CASSETTE_NO":"58321212","SAMPLE_DT":"07/08/2019","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2019-07-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1363,"firstDate":"2011-02-01","lastDate":"2019-10-10","metrics":{"ss":319,"amountDue":688762,"contested":0,"amountPaid":688762,"recentRows":0,"section104d":10,"unterminated":0,"proposedPenalty":813411},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1169373","VIOLATION_NO":"9144897","VIOLATION_ISSUE_DT":"10/10/2019","SIG_SUB":"N","PART_SECTION":"75.1600-3(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"10/10/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-10-10"},{"SOURCE_ROW_NUMBER":"1168949","VIOLATION_NO":"9149257","VIOLATION_ISSUE_DT":"09/05/2019","SIG_SUB":"N","PART_SECTION":"75.1909(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/05/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-09-05"},{"SOURCE_ROW_NUMBER":"1168961","VIOLATION_NO":"9149441","VIOLATION_ISSUE_DT":"08/30/2019","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/04/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-08-30"},{"SOURCE_ROW_NUMBER":"1168960","VIOLATION_NO":"9149420","VIOLATION_ISSUE_DT":"08/29/2019","SIG_SUB":"N","PART_SECTION":"75.1914(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2019","PROPOSED_PENALTY":"270","AMOUNT_DUE":"270","AMOUNT_PAID":"270","CONTESTED_IND":"N","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"1168959","VIOLATION_NO":"9149419","VIOLATION_ISSUE_DT":"08/29/2019","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"1168958","VIOLATION_NO":"9149418","VIOLATION_ISSUE_DT":"08/29/2019","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2019","PROPOSED_PENALTY":"2353","AMOUNT_DUE":"2353","AMOUNT_PAID":"2353","CONTESTED_IND":"N","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"1168957","VIOLATION_NO":"9149417","VIOLATION_ISSUE_DT":"08/29/2019","SIG_SUB":"N","PART_SECTION":"75.1911(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2019","PROPOSED_PENALTY":"230","AMOUNT_DUE":"230","AMOUNT_PAID":"230","CONTESTED_IND":"N","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"1168948","VIOLATION_NO":"9149256","VIOLATION_ISSUE_DT":"08/29/2019","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2019","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"1168947","VIOLATION_NO":"9149255","VIOLATION_ISSUE_DT":"08/29/2019","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"09/03/2019","CONTESTED_IND":"N","sourceDate":"2019-08-29"},{"SOURCE_ROW_NUMBER":"1168946","VIOLATION_NO":"9149254","VIOLATION_ISSUE_DT":"08/28/2019","SIG_SUB":"N","PART_SECTION":"48.9(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/29/2019","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2019-08-28"},{"SOURCE_ROW_NUMBER":"1168945","VIOLATION_NO":"9149253","VIOLATION_ISSUE_DT":"08/28/2019","SIG_SUB":"N","PART_SECTION":"75.204(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/29/2019","PROPOSED_PENALTY":"121","AMOUNT_DUE":"121","AMOUNT_PAID":"121","CONTESTED_IND":"N","sourceDate":"2019-08-28"},{"SOURCE_ROW_NUMBER":"1168944","VIOLATION_NO":"9149252","VIOLATION_ISSUE_DT":"08/27/2019","SIG_SUB":"N","PART_SECTION":"75.350(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/27/2019","PROPOSED_PENALTY":"214","AMOUNT_DUE":"214","AMOUNT_PAID":"214","CONTESTED_IND":"N","sourceDate":"2019-08-27"}]}],"safety":{"href":"/api/v1/mines/1519424/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519424/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1600-3","heading":"Communications facilities; refuge alternatives.","id":"75.1600-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-Q/section-75.1600-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Communications","text":"(a) Refuge alternatives shall be provided with a communications system that consists of—\n\n(1) A two-way communication facility that is a part of the mine communication system, which can be used from inside the refuge alternative; and\n\n(2) An additional communication system and other requirements as defined in the communications portion of the operator's approved Emergency Response Plan.\n\n[73 FR 80700, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1909","heading":"Nonpermissible diesel-powered equipment; design and performance requirements.","id":"75.1909","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1909","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:\n\n(1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;\n\n(2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;\n\n(3) A fuel system specifically designed for diesel fuel meeting the following requirements:\n\n(i) A fuel tank and fuel lines that do not leak;\n\n(ii) A fuel tank that is substantially constructed and protected against damage by collision;\n\n(iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;\n\n(iv) A self-closing filler cap on the fuel tank;\n\n(v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;\n\n(vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;\n\n(vii) Fuel line piping must be clamped;\n\n(viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;\n\n(ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;\n\n(x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and\n\n(xi) A water separator and fuel filter(s) must be provided.\n\n(4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;\n\n(5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;\n\n(6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;\n\n(7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;\n\n(8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;\n\n(9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and\n\n(10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.\n\n(b) Self-propelled nonpermissible diesel-powered equipment must have the following features in addition to those in paragraph (a):\n\n(1) A means to ensure that no stored hydraulic energy that will cause machine articulation is available after the engine is shut down;\n\n(2) A neutral start feature which ensures that engine cranking torque will not be transmitted through the powertrain and cause machine movement on vehicles utilizing fluid power transmissions;\n\n(3) For machines with steering wheels, brake pedals, and accelerator pedals, controls which are of automobile orientation;\n\n(4) An audible warning device conveniently located near the equipment operator;\n\n(5) Lights provided and maintained on both ends of the equipment. Equipment normally operated in both directions must be equipped with headlights for both directions;\n\n(6) Service brakes that act on each wheel of the vehicle and that are designed such that failure of any single component, except the brake actuation pedal or other similar actuation device, must not result in a complete loss of service braking capability;\n\n(7) Service brakes that safely bring the fully loaded vehicle to a complete stop on the maximum grade on which it is operated; and\n\n(8) No device that traps a column of fluid to hold the brake in the applied position shall be installed in any brake system, unless the trapped column of fluid is released when the equipment operator is no longer in contact with the brake activation device.\n\n(c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:\n\n(1) Engages automatically within 5 seconds of the shutdown of the engine;\n\n(2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;\n\n(4) Releases only by a manual control that does not operate any other equipment function;\n\n(5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and\n\n(6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.\n\n(e) The supplemental and park brake systems required by paragraphs (c) and (d) must be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n(f) Self-propelled personnel-elevating work platforms must be provided with a means to ensure that the parking braking system is released before the equipment can be trammed, and must be designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(g) Any nonpermissible equipment that discharges its exhaust directly into a return air course must be provided with a power package approved under subpart F of part 7 of this title.\n\n(h) Self-propelled nonpermissible heavy-duty diesel-powered equipment meeting the requirements of § 75.1908(a) must be provided with an automatic fire suppression system meeting the requirements of § 75.1911.\n\n(i) Self-propelled nonpermissible light-duty diesel-powered equipment meeting the requirements of § 75.1908(b) must be provided with an automatic or manual fire suppression system meeting the requirements of § 75.1911.\n\n(j) Nonpermissible equipment that is not self-propelled must have the following features in addition to those listed in paragraph (a):\n\n(1) A means to prevent inadvertent movement of the equipment when parked;\n\n(2) Safety chains or other suitable secondary connections on equipment that is being towed; and\n\n(3) An automatic fire suppression system meeting the requirements of § 75.1911.\n\n[61 FR 55527, Oct. 25, 1996; 62 FR 34641, June 27, 1997]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1914","heading":"Maintenance of diesel-powered equipment.","id":"75.1914","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1914","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Diesel-powered equipment shall be maintained in approved and safe condition or removed from service.\n\n(b) Maintenance and repairs of approved features and those features required by §§ 75.1909 and 75.1910 on diesel-powered equipment shall be made only by a person qualified under § 75.1915.\n\n(c) The water scrubber system on diesel-powered equipment shall be drained and flushed, by a person who is trained to perform this task, at least once on each shift in which the equipment is operated.\n\n(d) The intake air filter on diesel-powered equipment shall be replaced or serviced, by a person who is trained to perform this task, when the intake air pressure drop device so indicates or when the engine manufacturer's maximum allowable air pressure drop level is exceeded.\n\n(e) Mobile diesel-powered equipment that is to be used during a shift shall be visually examined by the equipment operator before being placed in operation. Equipment defects affecting safety shall be reported promptly to the mine operator.\n\n(f) All diesel-powered equipment shall be examined and tested weekly by a person qualified under § 75.1915.\n\n(1) Examinations and tests shall be conducted in accordance with approved checklists and manufacturers' maintenance manuals.\n\n(2) Persons performing weekly examinations and tests of diesel-powered equipment under this paragraph shall make a record when the equipment is not in approved or safe condition. The record shall include the equipment that is not in approved or safe condition, the defect found, and the corrective action taken.\n\n(g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:\n\n(1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;\n\n(2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;\n\n(3) The method of evaluation and interpretation of the results;\n\n(4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and\n\n(5) The maintenance of records necessary to track engine performance.\n\n(h) Recordkeeping. Records required by paragraphs (f)(2) and (g)(5) shall be—\n\n(1) Recorded in a secure book that is not susceptible to alteration, or recorded electronically in a computer system that is secure and not susceptible to alteration; and\n\n(2) Retained at a surface location at the mine for at least 1 year and made available for inspection by an authorized representative of the Secretary and by miners' representatives.\n\n(i) Diesel-powered equipment must be maintained in accordance with this part as of November 25, 1997.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1911","heading":"Fire suppression systems for diesel-powered equipment and fuel transportation units.","id":"75.1911","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1911","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) The fire suppression system required by §§ 75.1907 and 75.1909 shall be a multipurpose dry chemical type (ABC) fire suppression system listed or approved by a nationally recognized independent testing laboratory and appropriate for installation on diesel-powered equipment and fuel transportation units.\n\n(1) The system shall be installed in accordance with the manufacturer's specifications and the limitations of the listing or approval.\n\n(2) The system shall be installed in a protected location or guarded to minimize physical damage from routine vehicle operations.\n\n(3) Suppressant agent distribution tubing or piping shall be secured and protected against damage, including pinching, crimping, stretching, abrasion, and corrosion.\n\n(4) Discharge nozzles shall be positioned and aimed for maximum fire suppression effectiveness. Nozzles shall also be protected against the entrance of foreign materials such as mud, coal dust, or rock dust.\n\n(b) The fire suppression system shall provide fire suppression and, if automatic, fire detection for the engine including the starter, transmission, hydraulic pumps and tanks, fuel tanks, exposed brake units, air compressors and battery areas on diesel-powered equipment and electric panels or controls used on fuel transportation units and other areas as necessary.\n\n(c) If automatic, the fire suppression system shall include audible and visual alarms to warn of fires or system faults.\n\n(d) The fire suppression system shall provide for automatic engine shutdown. If the fire suppression system is automatic, engine shutdown and discharge of suppressant agent may be delayed for a maximum of 15 seconds after the fire is detected by the system.\n\n(e) The fire suppression system shall be operable by at least two manual actuators. One actuator shall be located on each side of the equipment. If the equipment is provided with an operator's compartment, one of the manual actuators shall be located in the compartment within reach of the operator.\n\n(f) The fire suppression system shall remain operative in the event of engine shutdown, equipment electrical system failure, or failure of any other equipment system.\n\n(g) The electrical components of each fire suppression system installed on equipment used where permissible electric equipment is required shall be permissible or intrinsically safe and such components shall be maintained in permissible or intrinsically safe condition.\n\n(h) Electrically operated detection and actuation circuits shall be monitored and provided with status indicators showing power and circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the functional readiness status of the detection system.\n\n(i) Each fire suppression system shall be tested and maintained in accordance with the manufacturer's recommended inspection and maintenance program and as required by the nationally recognized independent testing laboratory listing or approval, and be visually inspected at least once each week by a person trained to make such inspections.\n\n(j) Recordkeeping. Persons performing inspections and tests of fire suppression systems under paragraph (i) shall record when a fire suppression system does not meet the installation or maintenance requirements of this section.\n\n(1) The record shall include the equipment on which the fire suppression system did not meet the installation or maintenance requirements of this section, the defect found, and the corrective action taken.\n\n(2) Records are to be kept manually in a secure manner not susceptible to alteration or recorded electronically in a secured computer system that is not susceptible to alteration.\n\n(3) Records shall be maintained at a surface location at the mine for one year and made available for inspection by an authorized representative of the Secretary and miners' representatives.\n\n(k) All miners normally assigned to the active workings of the mine shall be instructed about the hazards inherent to the operation of the fire suppression systems and, where appropriate, the safeguards available for each system.\n\n(l) For purposes of § 75.380(f), a fire suppression system installed on diesel-powered equipment and meeting the requirements of this section is equivalent to a fire suppression system meeting the requirements of §§ 75.1107-3 through 75.1107-16.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","heading":"Records of training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-A/section-48.9","part":"48","subchapter":"H","subpart":"A","id":"48.9","citation":"30 CFR 48.9","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Roof bolting.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.204","part":"75","subchapter":"O","subpart":"C","id":"75.204","citation":"30 CFR 75.204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Belt air course ventilation.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.350","part":"75","subchapter":"O","subpart":"D","id":"75.350","citation":"30 CFR 75.350","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519424","dataSource":"postgres","snapshotId":"2026-10-17T05:35:58.500035+00:00","completedAt":"2026-10-17T06:17:15.228Z","sourceCount":20,"totalRows":15450873}}