{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519414","name":"#3","status":"Abandoned","status_date":"2009-12-23","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Pikeville","operator_id":"0087105","operator_name":"B & K Coal Inc","controller_id":"0073313","controller_name":"Bee  Handshoe","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.519166,"longitude":-82.519166},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":185},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519414","name":"#3"},"operator":{"type":"operator","id":"0087105","name":"B & K Coal Inc"},"controller":{"type":"controller","id":"0073313","name":"Bee  Handshoe"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0073313","name":"Bee  Handshoe"},"object":{"type":"mine","id":"1519414","name":"#3"},"validFrom":"2008-03-03","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519414|0073313|2008-03-03|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0087105","name":"B & K Coal Inc"},"object":{"type":"mine","id":"1519414","name":"#3"},"validFrom":"2009-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519414|0087105|2009-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0073313","name":"Bee  Handshoe"},"object":{"type":"operator","id":"0087105","name":"B & K Coal Inc"},"validFrom":"2009-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519414","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519414|0087105|2009-06-01|0073313|2008-03-03|11399"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2009-08-17","lastDate":"2009-08-17","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"255421","DOCUMENT_NO":"220092380025","ACCIDENT_DT":"08/17/2009","DEGREE_INJURY":"INJURIES DUE TO NATURAL CAUSES","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"NEC","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Rock picking and shoveling belt. Complained of abdominal pain and upset stomach.  Walked into mine office to see MET, sat down in chair, and fell over.  Alleged Miocardial Infarction (Heart Attack).  No sign of a work related accident.  This report is informative only due to it occuring on mine property.","sourceDate":"2009-08-17"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-12-23","lastDate":"2009-12-23","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":12,"firstDate":"2009-07-20","lastDate":"2009-08-28","metrics":{"ss":5,"delinquent":12,"recentRows":0,"paidPenalty":1373,"proposedPenalty":1373,"currentAssessment":1373},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1051732","VIOLATION_NO":"8231421","ISSUE_DT":"08/28/2009","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"249.00","CURRENT_ASSESSMENT_AMT":"249.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-28"},{"SOURCE_ROW_NUMBER":"1049056","VIOLATION_NO":"8230758","ISSUE_DT":"08/24/2009","CFR_STANDARD_CD":"75.364(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-24"},{"SOURCE_ROW_NUMBER":"1049055","VIOLATION_NO":"8230755","ISSUE_DT":"08/18/2009","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-18"},{"SOURCE_ROW_NUMBER":"1049054","VIOLATION_NO":"8230754","ISSUE_DT":"08/18/2009","CFR_STANDARD_CD":"48.8(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-18"},{"SOURCE_ROW_NUMBER":"1049053","VIOLATION_NO":"8230753","ISSUE_DT":"08/18/2009","CFR_STANDARD_CD":"48.26","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-18"},{"SOURCE_ROW_NUMBER":"1049059","VIOLATION_NO":"8230918","ISSUE_DT":"08/17/2009","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"1049058","VIOLATION_NO":"8230917","ISSUE_DT":"08/17/2009","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"1049057","VIOLATION_NO":"8230916","ISSUE_DT":"08/17/2009","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"1049052","VIOLATION_NO":"8230740","ISSUE_DT":"07/23/2009","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-23"},{"SOURCE_ROW_NUMBER":"1049051","VIOLATION_NO":"8230735","ISSUE_DT":"07/21/2009","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-21"},{"SOURCE_ROW_NUMBER":"1049050","VIOLATION_NO":"8230734","ISSUE_DT":"07/21/2009","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-21"},{"SOURCE_ROW_NUMBER":"1049049","VIOLATION_NO":"8230733","ISSUE_DT":"07/20/2009","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-20"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":7,"firstDate":"2009-08-03","lastDate":"2009-08-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":7,"maxConcentration":1.397,"concentrationTotal":2.737},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1615485","CASS_NUM":"57759837","SMP_TAKEN_DT":"8/3/2009","CONC":".043","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-08-03"},{"SOURCE_ROW_NUMBER":"1370014","CASS_NUM":"57759809","SMP_TAKEN_DT":"8/3/2009","CONC":".192","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-08-03"},{"SOURCE_ROW_NUMBER":"1360535","CASS_NUM":"57759616","SMP_TAKEN_DT":"8/3/2009","CONC":".322","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-08-03"},{"SOURCE_ROW_NUMBER":"1282340","CASS_NUM":"57759625","SMP_TAKEN_DT":"8/3/2009","CONC":"1.397","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-08-03"},{"SOURCE_ROW_NUMBER":"1210391","CASS_NUM":"57759736","SMP_TAKEN_DT":"8/3/2009","CONC":".127","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-08-03"},{"SOURCE_ROW_NUMBER":"1060756","CASS_NUM":"57759392","SMP_TAKEN_DT":"8/3/2009","CONC":".296","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-08-03"},{"SOURCE_ROW_NUMBER":"717475","CASS_NUM":"57759780","SMP_TAKEN_DT":"8/3/2009","CONC":".36","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-08-03"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":102,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2009-06-01","lastDate":"2009-06-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":7,"firstDate":"2009-06-02","lastDate":"2009-08-28","metrics":{"inspectors":14,"recentRows":0,"onSiteHours":106.25,"inspectionHours":188.75,"inspectionSamples":18},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"695086","EVENT_NO":"4196938","INSPECTION_BEGIN_DT":"08/28/2009","INSPECTION_END_DT":"09/03/2009","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2009-08-28"},{"SOURCE_ROW_NUMBER":"422930","EVENT_NO":"4197206","INSPECTION_BEGIN_DT":"08/17/2009","INSPECTION_END_DT":"02/26/2011","ACTIVITY_CODE":"E06","ACTIVITY":"Fatal Accident Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"34","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"848975","EVENT_NO":"4196932","INSPECTION_BEGIN_DT":"08/10/2009","INSPECTION_END_DT":"08/10/2009","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2009-08-10"},{"SOURCE_ROW_NUMBER":"1045580","EVENT_NO":"4196928","INSPECTION_BEGIN_DT":"07/23/2009","INSPECTION_END_DT":"07/23/2009","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2009-07-23"},{"SOURCE_ROW_NUMBER":"46909","EVENT_NO":"4196357","INSPECTION_BEGIN_DT":"07/08/2009","INSPECTION_END_DT":"09/15/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"88.75","SUM_TOTAL_ON_SITE_HOURS":"58.25","sourceDate":"2009-07-08"},{"SOURCE_ROW_NUMBER":"1116756","EVENT_NO":"4196957","INSPECTION_BEGIN_DT":"07/07/2009","INSPECTION_END_DT":"07/13/2009","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2009-07-07"},{"SOURCE_ROW_NUMBER":"1018478","EVENT_NO":"4196143","INSPECTION_BEGIN_DT":"06/02/2009","INSPECTION_END_DT":"06/05/2009","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2009-06-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009-Q3":{"hours":4541,"employees":21,"production":4408}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009":{"hours":4541,"employees":21,"production":4408}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":8,"firstDate":"2009-08-21","lastDate":"2009-08-24","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":542,"pelDoseTotal":447},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"105084","EVENT_NO":"4196357","SURVEY_DATE":"08/24/2009","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"57","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2009-08-24"},{"SOURCE_ROW_NUMBER":"105083","EVENT_NO":"4196357","SURVEY_DATE":"08/24/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"47","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2009-08-24"},{"SOURCE_ROW_NUMBER":"105082","EVENT_NO":"4196357","SURVEY_DATE":"08/21/2009","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"98","PEL_DOSE_90":"91","SURVEY_TYPE":"I","sourceDate":"2009-08-21"},{"SOURCE_ROW_NUMBER":"105081","EVENT_NO":"4196357","SURVEY_DATE":"08/21/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"038","ACT_DOSE_85":"92","PEL_DOSE_90":"90","SURVEY_TYPE":"I","sourceDate":"2009-08-21"},{"SOURCE_ROW_NUMBER":"105080","EVENT_NO":"4196357","SURVEY_DATE":"08/21/2009","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"55","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2009-08-21"},{"SOURCE_ROW_NUMBER":"105079","EVENT_NO":"4196357","SURVEY_DATE":"08/21/2009","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"55","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2009-08-21"},{"SOURCE_ROW_NUMBER":"105078","EVENT_NO":"4196357","SURVEY_DATE":"08/21/2009","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"86","PEL_DOSE_90":"58","SURVEY_TYPE":"I","sourceDate":"2009-08-21"},{"SOURCE_ROW_NUMBER":"105077","EVENT_NO":"4196357","SURVEY_DATE":"08/21/2009","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"52","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2009-08-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":16,"firstDate":"2009-07-20","lastDate":"2009-09-03","metrics":{"ss":5,"amountDue":1373,"contested":0,"amountPaid":1373,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":1373},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1166005","VIOLATION_NO":"8231423","VIOLATION_ISSUE_DT":"09/03/2009","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"08/28/2013","CONTESTED_IND":"N","sourceDate":"2009-09-03"},{"SOURCE_ROW_NUMBER":"1166004","VIOLATION_NO":"8231421","VIOLATION_ISSUE_DT":"08/28/2009","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"249","AMOUNT_DUE":"249","AMOUNT_PAID":"249","CONTESTED_IND":"N","sourceDate":"2009-08-28"},{"SOURCE_ROW_NUMBER":"1166003","VIOLATION_NO":"8227620","VIOLATION_ISSUE_DT":"08/28/2009","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"09/03/2009","CONTESTED_IND":"N","sourceDate":"2009-08-28"},{"SOURCE_ROW_NUMBER":"1165998","VIOLATION_NO":"8230758","VIOLATION_ISSUE_DT":"08/24/2009","SIG_SUB":"N","PART_SECTION":"75.364(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/10/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-08-24"},{"SOURCE_ROW_NUMBER":"1165997","VIOLATION_NO":"8230755","VIOLATION_ISSUE_DT":"08/18/2009","SIG_SUB":"N","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/18/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-08-18"},{"SOURCE_ROW_NUMBER":"1165996","VIOLATION_NO":"8230754","VIOLATION_ISSUE_DT":"08/18/2009","SIG_SUB":"N","PART_SECTION":"48.8(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/24/2009","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2009-08-18"},{"SOURCE_ROW_NUMBER":"1165995","VIOLATION_NO":"8230753","VIOLATION_ISSUE_DT":"08/18/2009","SIG_SUB":"N","PART_SECTION":"48.26","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/18/2009","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2009-08-18"},{"SOURCE_ROW_NUMBER":"1166002","VIOLATION_NO":"8231260","VIOLATION_ISSUE_DT":"08/17/2009","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"08/17/2009","CONTESTED_IND":"N","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"1166001","VIOLATION_NO":"8230918","VIOLATION_ISSUE_DT":"08/17/2009","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/17/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"1166000","VIOLATION_NO":"8230917","VIOLATION_ISSUE_DT":"08/17/2009","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/17/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"1165999","VIOLATION_NO":"8230916","VIOLATION_ISSUE_DT":"08/17/2009","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/17/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-08-17"},{"SOURCE_ROW_NUMBER":"1165994","VIOLATION_NO":"8230740","VIOLATION_ISSUE_DT":"07/23/2009","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/23/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-07-23"}]}],"safety":{"href":"/api/v1/mines/1519414/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519414/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","heading":"Annual refresher training of miners; minimum courses of instruction; hours of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-A/section-48.8","part":"48","subchapter":"H","subpart":"A","id":"48.8","citation":"30 CFR 48.8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Experienced miner training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.26","part":"48","subchapter":"H","subpart":"B","id":"48.26","citation":"30 CFR 48.26","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519414","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}