{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519410","name":"Tantrough","status":"Abandoned and Sealed","status_date":"2012-05-09","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Leslie","nearest_town":"Bledsoe","operator_id":"P23317","operator_name":"Bledsoe Coal Corporation","controller_id":"C13562","controller_name":"James River Coal Company","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":37.001944,"longitude":-83.298611},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1213},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519410","name":"Tantrough"},"operator":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corporation"},"controller":{"type":"controller","id":"C13562","name":"James River Coal Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1519410","name":"Tantrough"},"validFrom":"1995-06-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519410|C13562|1995-06-20|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corporation"},"object":{"type":"mine","id":"1519410","name":"Tantrough"},"validFrom":"2009-05-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519410|P23317|2009-05-19|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corporation"},"validFrom":"2009-05-19","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519410","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519410|P23317|2009-05-19|C13562|1995-06-20|90398"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":10,"firstDate":"2009-07-16","lastDate":"2012-01-05","metrics":{"daysLost":75,"injuries":8,"fatalities":0,"recentRows":0,"restrictedDays":28,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"100331","DOCUMENT_NO":"220120100020","ACCIDENT_DT":"01/05/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee is a roof bolt operator, while strapping top strap fell striking top of right hand, employee received 2 sutures and has returned to reg. duty with no restrictions.","sourceDate":"2012-01-05"},{"SOURCE_ROW_NUMBER":"96032","DOCUMENT_NO":"220113550038","ACCIDENT_DT":"12/17/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"The injured employee was loading belt structure in the scoop bucket when he caught his right thumb between the structure and the bucket. He had a simple (hair line fracture at the end of his thumb. Returned to regular duty.","sourceDate":"2011-12-17"},{"SOURCE_ROW_NUMBER":"126022","DOCUMENT_NO":"220113390032","ACCIDENT_DT":"11/29/2011","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was in #5 entry installing roof bolts, during this time employee raised head on bolter, not aware of where his right hand was placed employee caught his right 3rd digit finger with the canopy of bolter causing injury to finger, employee has returned to work on light duty due to injury on 12/5/11.","sourceDate":"2011-11-29"},{"SOURCE_ROW_NUMBER":"134793","DOCUMENT_NO":"220111380002","ACCIDENT_DT":"03/21/2011","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"75","NARRATIVE":"On 3/21/2011 employee was pulling on a piece of belt when he strained his left shoulder. Employee became restricted on 5/16/2011 due to this injury.","sourceDate":"2011-03-21"},{"SOURCE_ROW_NUMBER":"104527","DOCUMENT_NO":"220103480002","ACCIDENT_DT":"12/09/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"During pillaring a planned fall occurred, the pressure from this fall effected the ventilation by blowing out the brattice line, production was stopped, workers brought out, and necessary steps were taken to restore ventilation. Ventilation has been restored.","sourceDate":"2010-12-09"},{"SOURCE_ROW_NUMBER":"117544","DOCUMENT_NO":"220102560015","ACCIDENT_DT":"09/08/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was walking by tailpiece when he tripped and fell hitting chin on tailpiece sutures required. Employee has returned to work with no restrictions.","sourceDate":"2010-09-08"},{"SOURCE_ROW_NUMBER":"44546","DOCUMENT_NO":"220101900005","ACCIDENT_DT":"07/06/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall was found in the Southmains (4 belt) at Brk. 3 between 1 & 2 entry, the size of the fall was approx. 20'L x 20'H x 7'W. No equipment or ventilation effected. The area has been cribbed and dangered off.","sourceDate":"2010-07-06"},{"SOURCE_ROW_NUMBER":"177956","DOCUMENT_NO":"220101830007","ACCIDENT_DT":"06/24/2010","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was pulling belt roller over waterline when soap dispenser nipple blowed out causing water pressure to hit right eye. Employee has been placed on restricted duty with inflammation to the right eye.","sourceDate":"2010-06-24"},{"SOURCE_ROW_NUMBER":"113260","DOCUMENT_NO":"220100490005","ACCIDENT_DT":"02/02/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was working on continous miner when he caught his left thumb in between two pieces of metal. Employee received sutures to left thumb. Employee has returned to regular duty with no restrictions.","sourceDate":"2010-02-02"},{"SOURCE_ROW_NUMBER":"182255","DOCUMENT_NO":"220092010017","ACCIDENT_DT":"07/16/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Superintendent","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was helping on roof bolter when a channel strap fell hitting left index finger. Sutures required, employee has returned to regular duty.","sourceDate":"2009-07-16"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-05-09","lastDate":"2012-05-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":249,"firstDate":"2009-07-08","lastDate":"2012-03-26","metrics":{"ss":96,"delinquent":225,"recentRows":0,"paidPenalty":109041.1,"proposedPenalty":130514,"currentAssessment":114189},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1467446","VIOLATION_NO":"8407198","ISSUE_DT":"03/26/2012","CFR_STANDARD_CD":"75.310(a)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-03-26"},{"SOURCE_ROW_NUMBER":"1467445","VIOLATION_NO":"8368907","ISSUE_DT":"03/26/2012","CFR_STANDARD_CD":"75.312(g)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-03-26"},{"SOURCE_ROW_NUMBER":"1467444","VIOLATION_NO":"8368906","ISSUE_DT":"03/26/2012","CFR_STANDARD_CD":"75.312(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-03-26"},{"SOURCE_ROW_NUMBER":"1978072","VIOLATION_NO":"8408163","ISSUE_DT":"02/23/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"946.00","CURRENT_ASSESSMENT_AMT":"946.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-02-23"},{"SOURCE_ROW_NUMBER":"1978071","VIOLATION_NO":"8408162","ISSUE_DT":"02/23/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-02-23"},{"SOURCE_ROW_NUMBER":"1978070","VIOLATION_NO":"8408157","ISSUE_DT":"02/08/2012","CFR_STANDARD_CD":"75.1106-5(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"1978069","VIOLATION_NO":"8408149","ISSUE_DT":"01/23/2012","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1978068","VIOLATION_NO":"8408148","ISSUE_DT":"01/23/2012","CFR_STANDARD_CD":"75.1107-9(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1978067","VIOLATION_NO":"8408147","ISSUE_DT":"01/23/2012","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1978066","VIOLATION_NO":"8408146","ISSUE_DT":"01/23/2012","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1978065","VIOLATION_NO":"8408142","ISSUE_DT":"01/18/2012","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-18"},{"SOURCE_ROW_NUMBER":"1978064","VIOLATION_NO":"8408141","ISSUE_DT":"01/18/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-01-18"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":112,"firstDate":"2011-05-10","lastDate":"2013-05-06","metrics":{"appeals":0,"decisions":112,"recentRows":0,"decisionPenalty":71028,"originalPenalty":87353},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"313051","VIOLATION_NO":"8363674","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"639.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"313050","VIOLATION_NO":"8363668","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"459.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"313049","VIOLATION_NO":"8362443","DOCKET_NO":"KENT 2012-152","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3400.00","DECISION_PENALTY_AMT":"2550.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"312227","VIOLATION_NO":"8405782","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"207.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"312226","VIOLATION_NO":"8363662","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"127.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"79177","VIOLATION_NO":"8363669","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"459.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"79176","VIOLATION_NO":"8363666","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"499.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"79175","VIOLATION_NO":"8363663","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"499.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"79174","VIOLATION_NO":"8362442","DOCKET_NO":"KENT 2012-152","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3400.00","DECISION_PENALTY_AMT":"2550.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"79107","VIOLATION_NO":"8363664","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"162.00","DECISION_PENALTY_AMT":"162.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"78815","VIOLATION_NO":"8405783","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"},{"SOURCE_ROW_NUMBER":"78814","VIOLATION_NO":"8363667","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"127.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2013-05-06"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":295,"firstDate":"2009-07-08","lastDate":"2012-01-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":61,"validSamples":234,"maxConcentration":2.389,"concentrationTotal":156.164},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1600993","CASS_NUM":"57912123","SMP_TAKEN_DT":"1/25/2012","CONC":".451","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"1462937","CASS_NUM":"57912125","SMP_TAKEN_DT":"1/25/2012","CONC":".649","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"1279113","CASS_NUM":"57912126","SMP_TAKEN_DT":"1/25/2012","CONC":".165","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"1183370","CASS_NUM":"57912124","SMP_TAKEN_DT":"1/25/2012","CONC":".623","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"1158805","CASS_NUM":"57912127","SMP_TAKEN_DT":"1/25/2012","CONC":".146","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"1117505","CASS_NUM":"57912121","SMP_TAKEN_DT":"1/25/2012","CONC":".813","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"861590","CASS_NUM":"57912128","SMP_TAKEN_DT":"1/25/2012","CONC":".073","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"128095","CASS_NUM":"57912120","SMP_TAKEN_DT":"1/25/2012","CONC":"1.305","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"1234126","CASS_NUM":"51061739","SMP_TAKEN_DT":"1/9/2012","CONC":"1.342","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-09"},{"SOURCE_ROW_NUMBER":"1601672","CASS_NUM":"57906572","SMP_TAKEN_DT":"1/6/2012","CONC":".684","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MOBILE BRIDGE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-06"},{"SOURCE_ROW_NUMBER":"1530101","CASS_NUM":"57906586","SMP_TAKEN_DT":"1/6/2012","CONC":".59","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-06"},{"SOURCE_ROW_NUMBER":"1444417","CASS_NUM":"57906573","SMP_TAKEN_DT":"1/6/2012","CONC":"1.213","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-01-06"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2010-11-24","lastDate":"2010-11-24","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":112,"firstDate":"2010-02-16","lastDate":"2012-01-23","metrics":{"decisions":112,"ssChanged":37,"recentRows":0,"decisionPenalty":71028,"proposedPenalty":87353},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"366403","CITATION_NO":"8408148","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"KENT 2012-746","DECISION_DT":"04/26/2013","CFR_STANDARD_CODE":"75.1107-9(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"136133","CITATION_NO":"8408147","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"KENT 2012-746","DECISION_DT":"04/26/2013","CFR_STANDARD_CODE":"75.523-3(b)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"499.00","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"80080","CITATION_NO":"8408146","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"KENT 2012-746","DECISION_DT":"04/26/2013","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"499.00","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"138647","CITATION_NO":"8408142","CITATION_ISSUE_DT":"01/18/2012","DOCKET_NO":"KENT 2012-746","DECISION_DT":"04/26/2013","CFR_STANDARD_CODE":"75.1100-2(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2012-01-18"},{"SOURCE_ROW_NUMBER":"84923","CITATION_NO":"8338908","CITATION_ISSUE_DT":"01/17/2012","DOCKET_NO":"KENT 2012-746","DECISION_DT":"04/26/2013","CFR_STANDARD_CODE":"75.333(d)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"263.00","DECISION_PENALTY_AMT":"263.00","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"84424","CITATION_NO":"8408140","CITATION_ISSUE_DT":"01/17/2012","DOCKET_NO":"KENT 2012-746","DECISION_DT":"04/26/2013","CFR_STANDARD_CODE":"75.380(d)(7)(i)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"193538","CITATION_NO":"8405781","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"KENT 2012-746","DECISION_DT":"04/26/2013","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1026.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"81991","CITATION_NO":"8405783","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","CFR_STANDARD_CODE":"62.130(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"81215","CITATION_NO":"8405782","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","CFR_STANDARD_CODE":"72.630(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"207.00","DECISION_PENALTY_AMT":"207.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"25460","CITATION_NO":"8363674","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"639.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"426394","CITATION_NO":"8363669","CITATION_ISSUE_DT":"08/22/2011","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","CFR_STANDARD_CODE":"75.523-3(b)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"459.00","sourceDate":"2011-08-22"},{"SOURCE_ROW_NUMBER":"420436","CITATION_NO":"8363667","CITATION_ISSUE_DT":"08/19/2011","DOCKET_NO":"KENT 2012-153","DECISION_DT":"05/06/2013","CFR_STANDARD_CODE":"75.1101-7(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"127.00","DECISION_PENALTY_AMT":"127.00","sourceDate":"2011-08-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":21,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2009-05-19","lastDate":"2009-05-19","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":35,"firstDate":"2009-06-05","lastDate":"2012-04-02","metrics":{"inspectors":81,"recentRows":0,"onSiteHours":1387.75,"inspectionHours":2373.5,"inspectionSamples":310},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"656415","EVENT_NO":"6425701","INSPECTION_BEGIN_DT":"04/02/2012","INSPECTION_END_DT":"05/08/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-04-02"},{"SOURCE_ROW_NUMBER":"245173","EVENT_NO":"6425764","INSPECTION_BEGIN_DT":"03/28/2012","INSPECTION_END_DT":"03/28/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2012-03-28"},{"SOURCE_ROW_NUMBER":"440196","EVENT_NO":"4451994","INSPECTION_BEGIN_DT":"03/22/2012","INSPECTION_END_DT":"03/26/2012","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"29","SUM_TOTAL_ON_SITE_HOURS":"14","sourceDate":"2012-03-22"},{"SOURCE_ROW_NUMBER":"612949","EVENT_NO":"4445881","INSPECTION_BEGIN_DT":"03/16/2012","INSPECTION_END_DT":"03/16/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2012-03-16"},{"SOURCE_ROW_NUMBER":"927299","EVENT_NO":"6425658","INSPECTION_BEGIN_DT":"01/05/2012","INSPECTION_END_DT":"03/01/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"151.5","SUM_TOTAL_ON_SITE_HOURS":"83","sourceDate":"2012-01-05"},{"SOURCE_ROW_NUMBER":"547855","EVENT_NO":"4445868","INSPECTION_BEGIN_DT":"12/22/2011","INSPECTION_END_DT":"12/23/2011","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2011-12-22"},{"SOURCE_ROW_NUMBER":"837629","EVENT_NO":"6425651","INSPECTION_BEGIN_DT":"10/03/2011","INSPECTION_END_DT":"11/15/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"160.5","SUM_TOTAL_ON_SITE_HOURS":"97","sourceDate":"2011-10-03"},{"SOURCE_ROW_NUMBER":"590855","EVENT_NO":"6425649","INSPECTION_BEGIN_DT":"08/15/2011","INSPECTION_END_DT":"09/29/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"120","SUM_TOTAL_ON_SITE_HOURS":"72.5","sourceDate":"2011-08-15"},{"SOURCE_ROW_NUMBER":"847893","EVENT_NO":"4446294","INSPECTION_BEGIN_DT":"06/29/2011","INSPECTION_END_DT":"07/05/2011","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2011-06-29"},{"SOURCE_ROW_NUMBER":"359321","EVENT_NO":"4444376","INSPECTION_BEGIN_DT":"04/05/2011","INSPECTION_END_DT":"04/06/2011","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2011-04-05"},{"SOURCE_ROW_NUMBER":"747136","EVENT_NO":"4451436","INSPECTION_BEGIN_DT":"04/04/2011","INSPECTION_END_DT":"06/22/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"185.75","SUM_TOTAL_ON_SITE_HOURS":"113","sourceDate":"2011-04-04"},{"SOURCE_ROW_NUMBER":"900196","EVENT_NO":"6425637","INSPECTION_BEGIN_DT":"03/31/2011","INSPECTION_END_DT":"04/04/2011","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"26","SUM_TOTAL_ON_SITE_HOURS":"15","sourceDate":"2011-03-31"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q2":{"hours":2040,"employees":8,"production":0},"2012-Q1":{"hours":19496,"employees":40,"production":30851},"2011-Q4":{"hours":23011,"employees":46,"production":31310},"2011-Q3":{"hours":28865,"employees":53,"production":41196},"2011-Q2":{"hours":28191,"employees":52,"production":42307},"2011-Q1":{"hours":29296,"employees":49,"production":49894},"2010-Q4":{"hours":25796,"employees":55,"production":33653},"2010-Q3":{"hours":35646,"employees":54,"production":42622},"2010-Q2":{"hours":33455,"employees":51,"production":47730},"2010-Q1":{"hours":29148,"employees":47,"production":37956},"2009-Q4":{"hours":25023,"employees":44,"production":32453},"2009-Q3":{"hours":26010,"employees":43,"production":31674}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009":{"hours":52202,"employees":38,"production":64723},"2010":{"hours":124045,"employees":52,"production":161961},"2011":{"hours":109363,"employees":50,"production":164707},"2012":{"hours":21536,"employees":24,"production":30851}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":62,"firstDate":"2009-07-08","lastDate":"2012-01-25","metrics":{"recentRows":0,"doseOver100":19,"actDoseTotal":5186,"pelDoseTotal":4153},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"105022","EVENT_NO":"6425658","SURVEY_DATE":"01/25/2012","OCCUPATION_CD_DESC":"MINE FOREMAN/MINE MANAGER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"34","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"105021","EVENT_NO":"6425658","SURVEY_DATE":"01/25/2012","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"24","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"105020","EVENT_NO":"6425658","SURVEY_DATE":"01/25/2012","OCCUPATION_CD_DESC":"CLERK/TIMEKEEPER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"7","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"105019","EVENT_NO":"6425658","SURVEY_DATE":"01/25/2012","OCCUPATION_CD_DESC":"OUTSIDE FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"105017","EVENT_NO":"6425651","SURVEY_DATE":"11/10/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"96","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2011-11-10"},{"SOURCE_ROW_NUMBER":"105016","EVENT_NO":"6425651","SURVEY_DATE":"11/10/2011","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"69","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2011-11-10"},{"SOURCE_ROW_NUMBER":"105015","EVENT_NO":"6425651","SURVEY_DATE":"11/10/2011","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"58","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2011-11-10"},{"SOURCE_ROW_NUMBER":"105014","EVENT_NO":"6425651","SURVEY_DATE":"11/10/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"57","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2011-11-10"},{"SOURCE_ROW_NUMBER":"105013","EVENT_NO":"6425651","SURVEY_DATE":"11/10/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"87","PEL_DOSE_90":"61","SURVEY_TYPE":"I","sourceDate":"2011-11-10"},{"SOURCE_ROW_NUMBER":"105012","EVENT_NO":"6425651","SURVEY_DATE":"11/09/2011","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"38","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2011-11-09"},{"SOURCE_ROW_NUMBER":"105011","EVENT_NO":"6425651","SURVEY_DATE":"11/09/2011","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"33","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2011-11-09"},{"SOURCE_ROW_NUMBER":"105010","EVENT_NO":"6425651","SURVEY_DATE":"11/09/2011","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"8","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2011-11-09"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":20,"firstDate":"2009-07-20","lastDate":"2012-01-25","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":8.3,"validSamples":19,"quartzPctTotal":127.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"126225","CASSETTE_NO":"57912121","SAMPLE_DT":"01/25/2012","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-25"},{"SOURCE_ROW_NUMBER":"125635","CASSETTE_NO":"57906586","SAMPLE_DT":"01/06/2012","QUARTZ_PCT":"07.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-06"},{"SOURCE_ROW_NUMBER":"109470","CASSETTE_NO":"57906519","SAMPLE_DT":"01/06/2012","QUARTZ_PCT":"07.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-06"},{"SOURCE_ROW_NUMBER":"105403","CASSETTE_NO":"57906572","SAMPLE_DT":"01/06/2012","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-06"},{"SOURCE_ROW_NUMBER":"63353","CASSETTE_NO":"57906583","SAMPLE_DT":"01/06/2012","QUARTZ_PCT":"08.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-06"},{"SOURCE_ROW_NUMBER":"5002","CASSETTE_NO":"57906523","SAMPLE_DT":"01/06/2012","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-06"},{"SOURCE_ROW_NUMBER":"138093","CASSETTE_NO":"57895995","SAMPLE_DT":"10/19/2011","QUARTZ_PCT":"07.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"130995","CASSETTE_NO":"57895878","SAMPLE_DT":"10/19/2011","QUARTZ_PCT":"07.8","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"20451","CASSETTE_NO":"57895981","SAMPLE_DT":"10/19/2011","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-19"},{"SOURCE_ROW_NUMBER":"52380","CASSETTE_NO":"57896170","SAMPLE_DT":"08/30/2011","QUARTZ_PCT":"06.2","OCC_CODE_DESC":"MOBILE BRIDGE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"159148","CASSETTE_NO":"51151502","SAMPLE_DT":"08/17/2011","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-17"},{"SOURCE_ROW_NUMBER":"7979","CASSETTE_NO":"51151421","SAMPLE_DT":"08/17/2011","QUARTZ_PCT":"02.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-17"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":251,"firstDate":"2009-07-08","lastDate":"2012-03-26","metrics":{"ss":96,"amountDue":114189,"contested":49,"amountPaid":109041.1,"recentRows":0,"section104d":1,"unterminated":0,"proposedPenalty":130514},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1165749","VIOLATION_NO":"8407198","VIOLATION_ISSUE_DT":"03/26/2012","SIG_SUB":"N","PART_SECTION":"75.310(a)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-03-26"},{"SOURCE_ROW_NUMBER":"1165748","VIOLATION_NO":"8368907","VIOLATION_ISSUE_DT":"03/26/2012","SIG_SUB":"N","PART_SECTION":"75.312(g)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-03-26"},{"SOURCE_ROW_NUMBER":"1165747","VIOLATION_NO":"8368906","VIOLATION_ISSUE_DT":"03/26/2012","SIG_SUB":"N","PART_SECTION":"75.312(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-03-26"},{"SOURCE_ROW_NUMBER":"1165746","VIOLATION_NO":"8368905","VIOLATION_ISSUE_DT":"03/22/2012","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"03/28/2012","CONTESTED_IND":"N","sourceDate":"2012-03-22"},{"SOURCE_ROW_NUMBER":"1165662","VIOLATION_NO":"8408163","VIOLATION_ISSUE_DT":"02/23/2012","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/27/2012","PROPOSED_PENALTY":"946","AMOUNT_DUE":"946","AMOUNT_PAID":"946","CONTESTED_IND":"N","sourceDate":"2012-02-23"},{"SOURCE_ROW_NUMBER":"1165661","VIOLATION_NO":"8408162","VIOLATION_ISSUE_DT":"02/23/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/27/2012","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"176","CONTESTED_IND":"N","sourceDate":"2012-02-23"},{"SOURCE_ROW_NUMBER":"1165660","VIOLATION_NO":"8408157","VIOLATION_ISSUE_DT":"02/08/2012","SIG_SUB":"N","PART_SECTION":"75.1106-5(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/08/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-02-08"},{"SOURCE_ROW_NUMBER":"1165659","VIOLATION_NO":"8408149","VIOLATION_ISSUE_DT":"01/23/2012","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/30/2012","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"190","CONTESTED_IND":"N","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1165658","VIOLATION_NO":"8408148","VIOLATION_ISSUE_DT":"01/23/2012","SIG_SUB":"N","PART_SECTION":"75.1107-9(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/30/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1165657","VIOLATION_NO":"8408147","VIOLATION_ISSUE_DT":"01/23/2012","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2012","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"499","CONTESTED_IND":"N","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1165656","VIOLATION_NO":"8408146","VIOLATION_ISSUE_DT":"01/23/2012","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2012","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"499","CONTESTED_IND":"N","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"1165655","VIOLATION_NO":"8408142","VIOLATION_ISSUE_DT":"01/18/2012","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"10","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/23/2012","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2012-01-18"}]}],"safety":{"href":"/api/v1/mines/1519410/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519410/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","heading":"Maintenance and tests of liquefied and nonliquefied compressed gas cylinders; accessories and equipment; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-5","part":"75","subchapter":"O","subpart":"L","id":"75.1106-5","citation":"30 CFR 75.1106-5","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-9","heading":"Dry chemical devices; capacity; minimum requirements.","id":"75.1107-9","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-9","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Dry chemical fire extinguishing systems used on underground equipment shall be of the multipurpose powder-type and shall include the following:\n\n(1) The system including all hose and nozzles shall be protected against the entrance of moisture, dust, or dirt;\n\n(2) The system shall be guarded against damage during operation of the equipment protected;\n\n(3) Hose and pipe shall be as short as possible; the distance between the chemical container and furthest nozzle shall not exceed 50 feet;\n\n(4) Hose, piping, and fittings between the actuator and the chemical container shall have a bursting pressure of 500 pounds per square inch (gage) or higher; the hose, piping, and fittings between the chemical container and the nozzles shall have a bursting pressure of 300 pounds per square inch (gage) or higher and\n\n(5) The system shall discharge in 1 minute or less, for quantities less than 50 pounds (nominal) 1 and in less than 2 minutes for quantities more than 50 pounds;\n\n1 Many dry chemical systems were originally designed for sodium bicarbonate before all-purpose chemical (ammonium phosphate) was shown to be more effective. Sodium bicarbonate is denser than ammonium phosphate; hence, for example, a 50-pound system designed for the sodium bicarbonate will hold slightly more by weight than all-purpose dry chemical (ammonium phosphate) by weight. The word “nominal” is used in § 75.1107-9 to express the approximate weight in pounds of all-purpose dry chemical.\n\n(b) On unattended underground equipment, the number of pounds of dry chemical employed by the system shall be not less than 1 pound per square foot of top surface area of the equipment; however, the minimum amount in any system shall be 20 pounds (nominal). The discharge shall be directed into and on potentially hazardous locations of the equipment.\n\n(c) On attended underground equipment, the number of pounds (nominal) employed by the system shall equal 5 times the total number of hazardous locations; however, the minimum amount in any system shall not be less than the following, except that systems on haulage vehicles installed prior to the effective date of this section may contain 20 pounds (nominal).\n\nType of equipment Dry chemical pounds (nominal) (1) Cutting machines 40 (2) Continuous miners 40 (3) Haulage vehicles 30 (4) All other attended equipment 20\n\n(d) The amount of dry chemical discharged into the cable reel compartments of attended underground equipment shall be approximately 25 percent of the total amount required to be discharged by the system; however, the quantity discharged into cable reel compartments need not exceed 10 pounds.\n\n[37 FR 15302, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519410","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}