{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519400","name":"No. 88","status":"Abandoned","status_date":"2023-11-01","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Knott","nearest_town":"Vicco","operator_id":"0134733","operator_name":"Blue Diamond Coal Company","controller_id":"0158381","controller_name":"Sev.en Global Investments a.s.","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.228333,"longitude":-83.039167},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1903},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519400","name":"No. 88"},"operator":{"type":"operator","id":"0134733","name":"Blue Diamond Coal Company"},"controller":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1519400","name":"No. 88"},"validFrom":"1995-06-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|C13562|1995-06-20|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1519400","name":"No. 88"},"validFrom":"1998-02-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|C13562|1998-02-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23186","name":"Leeco, Inc."},"object":{"type":"mine","id":"1519400","name":"No. 88"},"validFrom":"2009-05-04","validTo":"2011-12-24","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|P23186|2009-05-04|2011-12-24"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P23186","name":"Leeco, Inc."},"validFrom":"2009-05-04","validTo":"2011-12-24","current":false,"derived":true,"evidenceMineId":"1519400","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|P23186|2009-05-04|C13562|1995-06-20|90397"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24585","name":"Blue Diamond Coal Company"},"object":{"type":"mine","id":"1519400","name":"No. 88"},"validFrom":"2011-12-25","validTo":"2014-09-03","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|P24585|2011-12-25|2014-09-03"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P24585","name":"Blue Diamond Coal Company"},"validFrom":"2011-12-25","validTo":"2014-09-03","current":false,"derived":true,"evidenceMineId":"1519400","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|P24585|2011-12-25|C13562|1998-02-01|90411"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0134733","name":"Blue Diamond Coal Company"},"object":{"type":"mine","id":"1519400","name":"No. 88"},"validFrom":"2014-09-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|0134733|2014-09-04|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"mine","id":"1519400","name":"No. 88"},"validFrom":"2014-09-04","validTo":"2020-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|0109461|2014-09-04|2020-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0109461","name":"Blackhawk Mining LLC"},"object":{"type":"operator","id":"0134733","name":"Blue Diamond Coal Company"},"validFrom":"2014-09-04","validTo":"2020-05-31","current":false,"derived":true,"evidenceMineId":"1519400","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|0134733|2014-09-04|0109461|2014-09-04|19886"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"mine","id":"1519400","name":"No. 88"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|0158381|2020-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0158381","name":"Sev.en Global Investments a.s."},"object":{"type":"operator","id":"0134733","name":"Blue Diamond Coal Company"},"validFrom":"2020-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519400","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519400|0134733|2014-09-04|0158381|2020-06-01|32814"}}],"coverage":{"historyRecords":4,"edgeCount":11,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":13,"firstDate":"2011-12-14","lastDate":"2014-12-21","metrics":{"daysLost":273,"injuries":12,"fatalities":0,"recentRows":0,"restrictedDays":21,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"121830","DOCUMENT_NO":"220143640032","ACCIDENT_DT":"12/21/2014","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"Had an unintentional fall starting from the mine portal highwall and extending approximately 15' inside the fan portal. The fall dimensions are approximately 20' wide by 12' long by 6' high.","sourceDate":"2014-12-21"},{"SOURCE_ROW_NUMBER":"117543","DOCUMENT_NO":"220143450013","ACCIDENT_DT":"12/05/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was using a 4 to 1 multiplier wrench and the wrench slipped and caught his left index finger between the wrench and the continuous miner. Sutures were required.","sourceDate":"2014-12-05"},{"SOURCE_ROW_NUMBER":"177953","DOCUMENT_NO":"220142790015","ACCIDENT_DT":"09/30/2014","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Installing a guard back on the continuous miner and caught his right thumb between guard and boss block. Cut and pinched right thumb, 4 sutures required.","sourceDate":"2014-09-30"},{"SOURCE_ROW_NUMBER":"216713","DOCUMENT_NO":"220141570026","ACCIDENT_DT":"05/29/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"Employee was pulling feeder cable out of the way and into a break and strained his back.","sourceDate":"2014-05-29"},{"SOURCE_ROW_NUMBER":"10189","DOCUMENT_NO":"220141190087","ACCIDENT_DT":"04/24/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"31","NARRATIVE":"PICI Contract employee strained his lower back while helping hang the miner cable. He was lifting cable with his left shoulder and slipped on a rock and the cable fell on him.","sourceDate":"2014-04-24"},{"SOURCE_ROW_NUMBER":"143526","DOCUMENT_NO":"220140920037","ACCIDENT_DT":"03/27/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Scoop car/Scooptram operator, Load/Haul/Dump (LHD) operator, Teletram operator","NO_INJURIES":"1","DAYS_LOST":"42","NARRATIVE":"Employee was lifting miner cable and waterline and hanging it to the top and strained his back and shoulders.","sourceDate":"2014-03-27"},{"SOURCE_ROW_NUMBER":"61710","DOCUMENT_NO":"220140650009","ACCIDENT_DT":"02/21/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"32","NARRATIVE":"Employee was unloading timbers from a scoop bucket and strained himself in the groin area. Started missing work on 3/5/2014 due to swelling and complications that will require surgery.","sourceDate":"2014-02-21"},{"SOURCE_ROW_NUMBER":"79007","DOCUMENT_NO":"220133170004","ACCIDENT_DT":"11/05/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"Employee was operating shuttle car and as he was turning his coat sleeve caught the rib and it pulled his arm between car and the rib and bruised his arm in which medical personnel later put a cast on it to help protect the muscle and tendons from future damage.","sourceDate":"2013-11-05"},{"SOURCE_ROW_NUMBER":"143525","DOCUMENT_NO":"220123320014","ACCIDENT_DT":"11/16/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"77","NARRATIVE":"A continuous miner operator was aligning the miner up on the centerline and struck himself with the miner. He was diagnosed with a non-displaced hairline fracture to the pelvis.","sourceDate":"2012-11-16"},{"SOURCE_ROW_NUMBER":"216712","DOCUMENT_NO":"220123180062","ACCIDENT_DT":"11/10/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was pulling a hose off of the rock duster and caught his left hand on a wire and cut his hand. 2 sutures required.","sourceDate":"2012-11-10"},{"SOURCE_ROW_NUMBER":"44543","DOCUMENT_NO":"220122750003","ACCIDENT_DT":"09/26/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"60","NARRATIVE":"Employee was hanging a cable and the hanger slipped and cut his right 5th digit finger. Surgery required - started missing work 9/28/2012","sourceDate":"2012-09-26"},{"SOURCE_ROW_NUMBER":"126018","DOCUMENT_NO":"220121240006","ACCIDENT_DT":"05/02/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was walking through a c.c. and accidentally run into a roof strap that was hanging down. He cut his left face/jaw 5 sutures required.","sourceDate":"2012-05-02"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2023-11-01","lastDate":"2023-11-01","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":240,"firstDate":"2011-05-17","lastDate":"2022-03-15","metrics":{"ss":46,"delinquent":240,"recentRows":1,"paidPenalty":52204,"proposedPenalty":54230,"currentAssessment":52204},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1488151","VIOLATION_NO":"9280579","ISSUE_DT":"03/15/2022","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"133.00","CURRENT_ASSESSMENT_AMT":"133.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2022-03-15"},{"SOURCE_ROW_NUMBER":"1996106","VIOLATION_NO":"8385644","ISSUE_DT":"05/09/2016","CFR_STANDARD_CD":"77.507","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"540.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-05-09"},{"SOURCE_ROW_NUMBER":"1995088","VIOLATION_NO":"8396790","ISSUE_DT":"02/23/2016","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-23"},{"SOURCE_ROW_NUMBER":"1995087","VIOLATION_NO":"8396786","ISSUE_DT":"02/01/2016","CFR_STANDARD_CD":"75.523-3(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2016-02-01"},{"SOURCE_ROW_NUMBER":"1995071","VIOLATION_NO":"8377997","ISSUE_DT":"11/18/2015","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-18"},{"SOURCE_ROW_NUMBER":"1995073","VIOLATION_NO":"8409682","ISSUE_DT":"11/16/2015","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-16"},{"SOURCE_ROW_NUMBER":"1995072","VIOLATION_NO":"8409681","ISSUE_DT":"11/16/2015","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-11-16"},{"SOURCE_ROW_NUMBER":"1995070","VIOLATION_NO":"8377994","ISSUE_DT":"10/13/2015","CFR_STANDARD_CD":"75.1714-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"1997376","VIOLATION_NO":"8389994","ISSUE_DT":"08/21/2015","CFR_STANDARD_CD":"75.380(d)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-21"},{"SOURCE_ROW_NUMBER":"1997375","VIOLATION_NO":"8389993","ISSUE_DT":"08/20/2015","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"112.00","CURRENT_ASSESSMENT_AMT":"112.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-20"},{"SOURCE_ROW_NUMBER":"1997374","VIOLATION_NO":"8389992","ISSUE_DT":"08/19/2015","CFR_STANDARD_CD":"75.1714-8(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-19"},{"SOURCE_ROW_NUMBER":"1997373","VIOLATION_NO":"8389991","ISSUE_DT":"08/18/2015","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"196.00","CURRENT_ASSESSMENT_AMT":"196.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2015-08-18"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":32,"firstDate":"2013-01-14","lastDate":"2016-10-12","metrics":{"appeals":0,"decisions":32,"recentRows":0,"decisionPenalty":14534,"originalPenalty":16560},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"122623","VIOLATION_NO":"8385644","DOCKET_NO":"KENT 2016-0426","DECISION_DT":"10/12/2016","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2016-10-12"},{"SOURCE_ROW_NUMBER":"118666","VIOLATION_NO":"8321877","DOCKET_NO":"KENT 2016-0122","DECISION_DT":"07/01/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2016-07-01"},{"SOURCE_ROW_NUMBER":"117595","VIOLATION_NO":"8389985","DOCKET_NO":"KENT 2016-0015","DECISION_DT":"03/16/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2016-03-16"},{"SOURCE_ROW_NUMBER":"115847","VIOLATION_NO":"8321872","DOCKET_NO":"KENT 2016-0033","DECISION_DT":"03/16/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"300.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2016-03-16"},{"SOURCE_ROW_NUMBER":"375516","VIOLATION_NO":"8321876","DOCKET_NO":"KENT 2015-0671","DECISION_DT":"01/29/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2016-01-29"},{"SOURCE_ROW_NUMBER":"116986","VIOLATION_NO":"8321878","DOCKET_NO":"KENT 2015-0671","DECISION_DT":"01/29/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2016-01-29"},{"SOURCE_ROW_NUMBER":"116985","VIOLATION_NO":"8321875","DOCKET_NO":"KENT 2015-0671","DECISION_DT":"01/29/2016","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2016-01-29"},{"SOURCE_ROW_NUMBER":"373984","VIOLATION_NO":"8413009","DOCKET_NO":"KENT 2015-0537","DECISION_DT":"12/04/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-12-04"},{"SOURCE_ROW_NUMBER":"373983","VIOLATION_NO":"8413008","DOCKET_NO":"KENT 2015-0537","DECISION_DT":"12/04/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-12-04"},{"SOURCE_ROW_NUMBER":"373806","VIOLATION_NO":"8388294","DOCKET_NO":"KENT 2015-0537","DECISION_DT":"12/04/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"499.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2015-12-04"},{"SOURCE_ROW_NUMBER":"372822","VIOLATION_NO":"8322677","DOCKET_NO":"KENT 2015-0477","DECISION_DT":"10/26/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2015-10-26"},{"SOURCE_ROW_NUMBER":"372570","VIOLATION_NO":"8322678","DOCKET_NO":"KENT 2015-0477","DECISION_DT":"10/26/2015","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2015-10-26"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":449,"firstDate":"2011-06-13","lastDate":"2015-11-03","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":60,"validSamples":389,"maxConcentration":2.81,"concentrationTotal":204.348},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1575369","CASS_NUM":"51394500","SMP_TAKEN_DT":"11/3/2015","CONC":".247","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"357468","CASS_NUM":"51394531","SMP_TAKEN_DT":"11/3/2015","CONC":".098","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-11-03"},{"SOURCE_ROW_NUMBER":"1411180","CASS_NUM":"51404753","SMP_TAKEN_DT":"10/15/2015","CONC":".238","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-15"},{"SOURCE_ROW_NUMBER":"198764","CASS_NUM":"51404752","SMP_TAKEN_DT":"10/15/2015","CONC":".312","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-15"},{"SOURCE_ROW_NUMBER":"1372998","CASS_NUM":"51404744","SMP_TAKEN_DT":"10/14/2015","CONC":".506","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-14"},{"SOURCE_ROW_NUMBER":"1452513","CASS_NUM":"58220842","SMP_TAKEN_DT":"10/13/2015","CONC":".752","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"1404074","CASS_NUM":"58220761","SMP_TAKEN_DT":"10/13/2015","CONC":".362","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"1079381","CASS_NUM":"58220977","SMP_TAKEN_DT":"10/13/2015","CONC":".62","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"963193","CASS_NUM":"58220769","SMP_TAKEN_DT":"10/13/2015","CONC":".484","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"591566","CASS_NUM":"58220696","SMP_TAKEN_DT":"10/13/2015","CONC":".051","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"514549","CASS_NUM":"58220994","SMP_TAKEN_DT":"10/13/2015","CONC":".19","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"504513","CASS_NUM":"58220998","SMP_TAKEN_DT":"10/13/2015","CONC":".465","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2015-10-13"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2015-04-07","lastDate":"2022-05-23","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":32,"firstDate":"2011-09-28","lastDate":"2016-05-09","metrics":{"decisions":32,"ssChanged":2,"recentRows":0,"decisionPenalty":14534,"proposedPenalty":16560},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"98870","CITATION_NO":"8385644","CITATION_ISSUE_DT":"05/09/2016","DOCKET_NO":"KENT 2016-0426","DECISION_DT":"10/12/2016","CFR_STANDARD_CODE":"77.507","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","sourceDate":"2016-05-09"},{"SOURCE_ROW_NUMBER":"318822","CITATION_NO":"8389985","CITATION_ISSUE_DT":"08/05/2015","DOCKET_NO":"KENT 2016-0015","DECISION_DT":"03/16/2016","CFR_STANDARD_CODE":"75.607","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2015-08-05"},{"SOURCE_ROW_NUMBER":"433178","CITATION_NO":"8321875","CITATION_ISSUE_DT":"05/05/2015","DOCKET_NO":"KENT 2015-0671","DECISION_DT":"01/29/2016","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2015-05-05"},{"SOURCE_ROW_NUMBER":"210455","CITATION_NO":"8321878","CITATION_ISSUE_DT":"05/05/2015","DOCKET_NO":"KENT 2015-0671","DECISION_DT":"01/29/2016","CFR_STANDARD_CODE":"75.362(a)(3)(i)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2015-05-05"},{"SOURCE_ROW_NUMBER":"97154","CITATION_NO":"8321877","CITATION_ISSUE_DT":"05/05/2015","DOCKET_NO":"KENT 2016-0122","DECISION_DT":"07/01/2016","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2015-05-05"},{"SOURCE_ROW_NUMBER":"36596","CITATION_NO":"8321876","CITATION_ISSUE_DT":"05/05/2015","DOCKET_NO":"KENT 2015-0671","DECISION_DT":"01/29/2016","CFR_STANDARD_CODE":"75.362(a)(3)(iv)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2015-05-05"},{"SOURCE_ROW_NUMBER":"265660","CITATION_NO":"8321872","CITATION_ISSUE_DT":"05/04/2015","DOCKET_NO":"KENT 2016-0033","DECISION_DT":"03/16/2016","CFR_STANDARD_CODE":"75.903","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"300.00","sourceDate":"2015-05-04"},{"SOURCE_ROW_NUMBER":"321111","CITATION_NO":"8413009","CITATION_ISSUE_DT":"03/19/2015","DOCKET_NO":"KENT 2015-0537","DECISION_DT":"12/04/2015","CFR_STANDARD_CODE":"75.1107-16(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","sourceDate":"2015-03-19"},{"SOURCE_ROW_NUMBER":"148790","CITATION_NO":"8413008","CITATION_ISSUE_DT":"03/19/2015","DOCKET_NO":"KENT 2015-0537","DECISION_DT":"12/04/2015","CFR_STANDARD_CODE":"75.1107-16(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","sourceDate":"2015-03-19"},{"SOURCE_ROW_NUMBER":"40057","CITATION_NO":"8322677","CITATION_ISSUE_DT":"03/02/2015","DOCKET_NO":"KENT 2015-0477","DECISION_DT":"10/26/2015","CFR_STANDARD_CODE":"75.340(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","sourceDate":"2015-03-02"},{"SOURCE_ROW_NUMBER":"36369","CITATION_NO":"8322678","CITATION_ISSUE_DT":"03/02/2015","DOCKET_NO":"KENT 2015-0477","DECISION_DT":"10/26/2015","CFR_STANDARD_CODE":"75.360(b)(9)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"190.00","DECISION_PENALTY_AMT":"190.00","sourceDate":"2015-03-02"},{"SOURCE_ROW_NUMBER":"33282","CITATION_NO":"8322679","CITATION_ISSUE_DT":"03/02/2015","DOCKET_NO":"KENT 2015-0478","DECISION_DT":"10/26/2015","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"112.00","DECISION_PENALTY_AMT":"112.00","sourceDate":"2015-03-02"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":468,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":124,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2009-05-04","lastDate":"2014-09-04","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":74,"firstDate":"2011-05-01","lastDate":"2023-09-07","metrics":{"inspectors":157,"recentRows":13,"onSiteHours":2012.5,"inspectionHours":3227.5,"inspectionSamples":598},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"280412","EVENT_NO":"4460601","INSPECTION_BEGIN_DT":"09/07/2023","INSPECTION_END_DT":"09/07/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2023-09-07"},{"SOURCE_ROW_NUMBER":"1131114","EVENT_NO":"7035306","INSPECTION_BEGIN_DT":"06/05/2023","INSPECTION_END_DT":"06/05/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2023-06-05"},{"SOURCE_ROW_NUMBER":"630265","EVENT_NO":"7037083","INSPECTION_BEGIN_DT":"01/12/2023","INSPECTION_END_DT":"01/12/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2023-01-12"},{"SOURCE_ROW_NUMBER":"1060482","EVENT_NO":"4462552","INSPECTION_BEGIN_DT":"10/11/2022","INSPECTION_END_DT":"10/11/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.25","SUM_TOTAL_ON_SITE_HOURS":".25","sourceDate":"2022-10-11"},{"SOURCE_ROW_NUMBER":"88012","EVENT_NO":"7037301","INSPECTION_BEGIN_DT":"09/29/2022","INSPECTION_END_DT":"09/29/2022","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2022-09-29"},{"SOURCE_ROW_NUMBER":"292954","EVENT_NO":"4462769","INSPECTION_BEGIN_DT":"07/27/2022","INSPECTION_END_DT":"07/27/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2022-07-27"},{"SOURCE_ROW_NUMBER":"281680","EVENT_NO":"4462793","INSPECTION_BEGIN_DT":"05/24/2022","INSPECTION_END_DT":"05/24/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2022-05-24"},{"SOURCE_ROW_NUMBER":"962083","EVENT_NO":"4462418","INSPECTION_BEGIN_DT":"03/15/2022","INSPECTION_END_DT":"06/30/2022","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2022-03-15"},{"SOURCE_ROW_NUMBER":"838139","EVENT_NO":"4462382","INSPECTION_BEGIN_DT":"01/03/2022","INSPECTION_END_DT":"01/06/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2022-01-03"},{"SOURCE_ROW_NUMBER":"580186","EVENT_NO":"4462369","INSPECTION_BEGIN_DT":"11/04/2021","INSPECTION_END_DT":"11/04/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2021-11-04"},{"SOURCE_ROW_NUMBER":"775222","EVENT_NO":"4462452","INSPECTION_BEGIN_DT":"07/19/2021","INSPECTION_END_DT":"07/19/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2021-07-19"},{"SOURCE_ROW_NUMBER":"1077009","EVENT_NO":"4462813","INSPECTION_BEGIN_DT":"04/05/2021","INSPECTION_END_DT":"04/05/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.5","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2021-04-05"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":84,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2023-Q4":{"hours":0,"employees":0,"production":0},"2023-Q3":{"hours":0,"employees":0,"production":0},"2023-Q2":{"hours":0,"employees":0,"production":0},"2023-Q1":{"hours":0,"employees":0,"production":0},"2022-Q4":{"hours":0,"employees":0,"production":0},"2022-Q3":{"hours":0,"employees":0,"production":0},"2022-Q2":{"hours":0,"employees":0,"production":0},"2022-Q1":{"hours":0,"employees":0,"production":0},"2021-Q4":{"hours":0,"employees":0,"production":0},"2021-Q3":{"hours":0,"employees":0,"production":0},"2021-Q2":{"hours":0,"employees":0,"production":0},"2021-Q1":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2011":{"hours":64045,"employees":38,"production":91407},"2012":{"hours":115903,"employees":48,"production":150388},"2013":{"hours":84063,"employees":42,"production":199206},"2014":{"hours":90884,"employees":41,"production":243201},"2015":{"hours":89556,"employees":40,"production":211619},"2016":{"hours":7352,"employees":8,"production":1607}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":90,"firstDate":"2011-06-24","lastDate":"2016-03-24","metrics":{"recentRows":0,"doseOver100":6,"actDoseTotal":4512,"pelDoseTotal":2836},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"104554","EVENT_NO":"6429810","SURVEY_DATE":"03/24/2016","OCCUPATION_CD_DESC":"MAINTENANCE FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"81","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2016-03-24"},{"SOURCE_ROW_NUMBER":"104553","EVENT_NO":"6429810","SURVEY_DATE":"03/24/2016","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"9","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2016-03-24"},{"SOURCE_ROW_NUMBER":"104552","EVENT_NO":"6429810","SURVEY_DATE":"03/24/2016","OCCUPATION_CD_DESC":"SUPERINTENDENT","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"6","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2016-03-24"},{"SOURCE_ROW_NUMBER":"104551","EVENT_NO":"6429810","SURVEY_DATE":"03/24/2016","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2016-03-24"},{"SOURCE_ROW_NUMBER":"104550","EVENT_NO":"6429810","SURVEY_DATE":"03/24/2016","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"3","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2016-03-24"},{"SOURCE_ROW_NUMBER":"104549","EVENT_NO":"6429804","SURVEY_DATE":"10/13/2015","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"25","MANUFACTURER_CD":"120","ACT_DOSE_85":"63","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"104548","EVENT_NO":"6429804","SURVEY_DATE":"10/13/2015","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"27","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"104547","EVENT_NO":"6429804","SURVEY_DATE":"10/13/2015","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"65","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"104546","EVENT_NO":"6429804","SURVEY_DATE":"10/13/2015","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"34","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"104545","EVENT_NO":"6429804","SURVEY_DATE":"10/13/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"104559","EVENT_NO":"6430389","SURVEY_DATE":"08/12/2015","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"060","ACT_DOSE_85":"27","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2015-08-12"},{"SOURCE_ROW_NUMBER":"104558","EVENT_NO":"6430389","SURVEY_DATE":"08/12/2015","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"57","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2015-08-12"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":31,"firstDate":"2011-08-17","lastDate":"2015-10-13","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":22.5,"validSamples":30,"quartzPctTotal":176.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"132988","CASSETTE_NO":"58220976","SAMPLE_DT":"10/13/2015","QUARTZ_PCT":"07.3","QUARTZ_MICROGRAMS":"58","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"129991","CASSETTE_NO":"58220994","SAMPLE_DT":"10/13/2015","QUARTZ_PCT":"05.9","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"70991","CASSETTE_NO":"58220842","SAMPLE_DT":"10/13/2015","QUARTZ_PCT":"05.5","QUARTZ_MICROGRAMS":"41","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"49126","CASSETTE_NO":"58220977","SAMPLE_DT":"10/13/2015","QUARTZ_PCT":"04.7","QUARTZ_MICROGRAMS":"29","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"146885","CASSETTE_NO":"58221104","SAMPLE_DT":"08/12/2015","QUARTZ_PCT":"05.8","QUARTZ_MICROGRAMS":"36","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-12"},{"SOURCE_ROW_NUMBER":"145898","CASSETTE_NO":"58221112","SAMPLE_DT":"08/12/2015","QUARTZ_PCT":"09.0","QUARTZ_MICROGRAMS":"24","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-12"},{"SOURCE_ROW_NUMBER":"22987","CASSETTE_NO":"58221111","SAMPLE_DT":"08/12/2015","QUARTZ_PCT":"22.5","QUARTZ_MICROGRAMS":"37","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-08-12"},{"SOURCE_ROW_NUMBER":"131107","CASSETTE_NO":"58209383","SAMPLE_DT":"05/11/2015","QUARTZ_PCT":"06.5","QUARTZ_MICROGRAMS":"40","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-11"},{"SOURCE_ROW_NUMBER":"119279","CASSETTE_NO":"58209107","SAMPLE_DT":"05/11/2015","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-11"},{"SOURCE_ROW_NUMBER":"43515","CASSETTE_NO":"58209435","SAMPLE_DT":"05/11/2015","QUARTZ_PCT":"05.4","QUARTZ_MICROGRAMS":"63","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-05-11"},{"SOURCE_ROW_NUMBER":"164533","CASSETTE_NO":"58183106","SAMPLE_DT":"02/03/2015","QUARTZ_PCT":"04.3","QUARTZ_MICROGRAMS":"16","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-02-03"},{"SOURCE_ROW_NUMBER":"12010","CASSETTE_NO":"58183099","SAMPLE_DT":"02/03/2015","QUARTZ_PCT":"05.2","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2015-02-03"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":245,"firstDate":"2011-05-17","lastDate":"2022-03-15","metrics":{"ss":46,"amountDue":52204,"contested":0,"amountPaid":52204,"recentRows":1,"section104d":0,"unterminated":0,"proposedPenalty":54230},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1163922","VIOLATION_NO":"9280579","VIOLATION_ISSUE_DT":"03/15/2022","SIG_SUB":"N","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/30/2022","PROPOSED_PENALTY":"133","AMOUNT_DUE":"133","AMOUNT_PAID":"133","CONTESTED_IND":"N","sourceDate":"2022-03-15"},{"SOURCE_ROW_NUMBER":"1163952","VIOLATION_NO":"8385644","VIOLATION_ISSUE_DT":"05/09/2016","SIG_SUB":"Y","PART_SECTION":"77.507","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/09/2016","PROPOSED_PENALTY":"540","AMOUNT_DUE":"540","AMOUNT_PAID":"540","CONTESTED_IND":"N","sourceDate":"2016-05-09"},{"SOURCE_ROW_NUMBER":"1163879","VIOLATION_NO":"8396790","VIOLATION_ISSUE_DT":"02/23/2016","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/29/2016","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2016-02-23"},{"SOURCE_ROW_NUMBER":"1163878","VIOLATION_NO":"8396786","VIOLATION_ISSUE_DT":"02/01/2016","SIG_SUB":"N","PART_SECTION":"75.523-3(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/01/2016","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2016-02-01"},{"SOURCE_ROW_NUMBER":"1164075","VIOLATION_NO":"8377997","VIOLATION_ISSUE_DT":"11/18/2015","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/18/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-18"},{"SOURCE_ROW_NUMBER":"1164077","VIOLATION_NO":"8409682","VIOLATION_ISSUE_DT":"11/16/2015","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/18/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-16"},{"SOURCE_ROW_NUMBER":"1164076","VIOLATION_NO":"8409681","VIOLATION_ISSUE_DT":"11/16/2015","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/16/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-11-16"},{"SOURCE_ROW_NUMBER":"1164074","VIOLATION_NO":"8377994","VIOLATION_ISSUE_DT":"10/13/2015","SIG_SUB":"N","PART_SECTION":"75.1714-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/13/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-10-13"},{"SOURCE_ROW_NUMBER":"1164052","VIOLATION_NO":"8389994","VIOLATION_ISSUE_DT":"08/21/2015","SIG_SUB":"N","PART_SECTION":"75.380(d)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/21/2015","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2015-08-21"},{"SOURCE_ROW_NUMBER":"1164051","VIOLATION_NO":"8389993","VIOLATION_ISSUE_DT":"08/20/2015","SIG_SUB":"N","SECTION_OF_ACT":"316(b)(2)(A)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/21/2015","PROPOSED_PENALTY":"112","AMOUNT_DUE":"112","AMOUNT_PAID":"112","CONTESTED_IND":"N","sourceDate":"2015-08-20"},{"SOURCE_ROW_NUMBER":"1164050","VIOLATION_NO":"8389992","VIOLATION_ISSUE_DT":"08/19/2015","SIG_SUB":"N","PART_SECTION":"75.1714-8(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"08/20/2015","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2015-08-19"},{"SOURCE_ROW_NUMBER":"1164049","VIOLATION_NO":"8389991","VIOLATION_ISSUE_DT":"08/18/2015","SIG_SUB":"N","SECTION_OF_ACT":"316(b)(2)(F)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/18/2015","PROPOSED_PENALTY":"196","AMOUNT_DUE":"196","AMOUNT_PAID":"196","CONTESTED_IND":"N","sourceDate":"2015-08-18"}]}],"safety":{"href":"/api/v1/mines/1519400/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519400/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; switches.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.507","part":"77","subchapter":"O","subpart":"F","id":"77.507","citation":"30 CFR 77.507","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1714-4","heading":"Additional self-contained self-rescuers (SCSRs).","id":"75.1714-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Additional SCSRs in work places. In addition to the requirements in §§ 75.1714, 75.1714-1, 75.1714-2, and 75.1714-3 of this part, the mine operator shall provide the following:\n\n(1) At least one additional SCSR, which provides protection for a period of one hour or longer, for each person at a fixed underground work location.\n\n(2) Additional SCSRs along the normal travel routes for pumpers, examiners, and other persons who do not have a fixed work location to be stored at a distance an average miner could walk in 30 minutes. The SCSR storage locations shall be determined by using one of the methods found under paragraph (c)(2) of this section.\n\n(b) Additional SCSRs on mantrips. If a mantrip or mobile equipment is used to enter or exit the mine, at least one additional SCSR, which provides protection for a period of one hour or longer, shall be available for each person who uses such transportation from portal to portal.\n\n(c) Additional SCSRs in escapeways. When each person underground cannot safely evacuate the mine within 30 minutes, the mine operator shall provide additional SCSRs stored in each required escapeway.\n\n(1) Each storage location shall contain at least one SCSR, which provides protection for a period of one hour or longer, for every person who will be inby that location.\n\n(2) Storage locations shall be spaced along each escapeway at 30-minute travel distances no greater than the distances determined by—\n\n(i) Calculating the distance an average miner walks in 30 minutes by using the time necessary for each miner in a sample of typical miners to walk a typical length of each escapeway; or\n\n(ii) Using the SCSR storage location spacing specified in the following table, except for escapeways with grades over 5 percent.\n\nAverage entry height Maximum distancebetween SCSR storage locations (in ft.) <40 in. (Crawl) 2,200 >40-<50 in. (Duck Walk) 3,300 >50-<65 in. (Walk Head Bent) 4,400 >65 in. (Walk Erect) 5,700\n\n(d) Additional SCSRs in hardened rooms. As an alternative to providing SCSR storage locations in each escapeway, the mine operator may store SCSRs in a hardened room located between adjacent escapeways.\n\n(1) The hardened room shall be designed and constructed to the same explosion force criteria as seals.\n\n(2) The hardened room shall include a means to provide independent, positive pressure ventilation from the surface during an emergency.\n\n(3) The District Manager shall approve the design and construction of hardened rooms in the ventilation plan.\n\n(4) These SCSR storage locations shall be spaced in accordance with paragraph (c) of this section.\n\n(e) Storage location accessibility. All SCSRs required under this section shall be stored according to the manufacturers' instructions, in conspicuous locations readily accessible by each person in the mine.\n\n(f) Storage location signs. A sign made of reflective material with the words “SCSRs” or “SELF-RESCUERS” shall be conspicuously posted at each storage location. Direction signs made of a reflective material shall be posted leading to each storage location.\n\n[71 FR 71454, Dec. 8, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Reporting SCSR inventory and malfunctions; retention of SCSRs.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-8","part":"75","subchapter":"O","subpart":"R","id":"75.1714-8","citation":"30 CFR 75.1714-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519400","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}