{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519323","name":"Slones Branch","status":"Abandoned and Sealed","status_date":"2014-08-13","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Knott","nearest_town":"Pippa Passes","operator_id":"0054616","operator_name":"KNOTT COUNTY COAL LLC","controller_id":"0150901","controller_name":"American Resources Corporation","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.373889,"longitude":-82.831944},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2096},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519323","name":"Slones Branch"},"operator":{"type":"operator","id":"0054616","name":"KNOTT COUNTY COAL LLC"},"controller":{"type":"controller","id":"0150901","name":"American Resources Corporation"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0045307","name":"International Coal Group Inc (ICG)"},"object":{"type":"mine","id":"1519323","name":"Slones Branch"},"validFrom":"2004-10-01","validTo":"2011-06-14","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0045307|2004-10-01|2011-06-14"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0054616","name":"KNOTT COUNTY COAL LLC"},"object":{"type":"mine","id":"1519323","name":"Slones Branch"},"validFrom":"2008-10-02","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0054616|2008-10-02|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0045307","name":"International Coal Group Inc (ICG)"},"object":{"type":"operator","id":"0054616","name":"KNOTT COUNTY COAL LLC"},"validFrom":"2008-10-02","validTo":"2011-06-14","current":false,"derived":true,"evidenceMineId":"1519323","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0054616|2008-10-02|0045307|2004-10-01|5276"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"mine","id":"1519323","name":"Slones Branch"},"validFrom":"2011-06-15","validTo":"2016-04-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|C15561|2011-06-15|2016-04-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"operator","id":"0054616","name":"KNOTT COUNTY COAL LLC"},"validFrom":"2011-06-15","validTo":"2016-04-11","current":false,"derived":true,"evidenceMineId":"1519323","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0054616|2008-10-02|C15561|2011-06-15|96094"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0111701","name":"Quest Energy Corporation"},"object":{"type":"mine","id":"1519323","name":"Slones Branch"},"validFrom":"2016-04-12","validTo":"2017-01-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0111701|2016-04-12|2017-01-04"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0111701","name":"Quest Energy Corporation"},"object":{"type":"operator","id":"0054616","name":"KNOTT COUNTY COAL LLC"},"validFrom":"2016-04-12","validTo":"2017-01-04","current":false,"derived":true,"evidenceMineId":"1519323","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0054616|2008-10-02|0111701|2016-04-12|20568"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0150901","name":"American Resources Corporation"},"object":{"type":"mine","id":"1519323","name":"Slones Branch"},"validFrom":"2017-01-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0150901|2017-01-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0150901","name":"American Resources Corporation"},"object":{"type":"operator","id":"0054616","name":"KNOTT COUNTY COAL LLC"},"validFrom":"2017-01-05","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519323","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519323|0054616|2008-10-02|0150901|2017-01-05|31136"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":18,"firstDate":"2009-05-04","lastDate":"2013-09-04","metrics":{"daysLost":747,"injuries":16,"fatalities":0,"recentRows":0,"restrictedDays":15,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"147845","DOCUMENT_NO":"220132540002","ACCIDENT_DT":"09/04/2013","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was adjusting the forks on a skidsteer unit to be able to pick up scrap. As he reached between the backing plate and the mast to unlock pin holding forks in place the operator tilted the forks back pinning his arm between backing plate and the mast. Employee ended up with a slight fracture and some minor muscle damage on left forearm.","sourceDate":"2013-09-04"},{"SOURCE_ROW_NUMBER":"165009","DOCUMENT_NO":"220121800037","ACCIDENT_DT":"06/20/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Roof strap was broke hanging down, principal was bending strap back and forth trying to break it off when he hit his right arm on the other end of the strap causing a laceration requiring 8 sutures.","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"203679","DOCUMENT_NO":"220113540032","ACCIDENT_DT":"12/14/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"NONPOWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Principal was unhooking utility trailer when the hitch came up with his right hand on top of the hitch hitting the mine roof cutting index finger, he had 5 sutures in his index finger.","sourceDate":"2011-12-14"},{"SOURCE_ROW_NUMBER":"233849","DOCUMENT_NO":"220112520037","ACCIDENT_DT":"08/31/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"133","NARRATIVE":"While traveling the intake on a mine buggy to work on the tracking system a piece of draw rock fell striking him.","sourceDate":"2011-08-31"},{"SOURCE_ROW_NUMBER":"96017","DOCUMENT_NO":"220112360031","ACCIDENT_DT":"08/13/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While driving a mine buggy the wheel of the buggy caught a rock, thus spinning the steering wheel which caught employee's left hand. This resulted in a laceration to his left hand requiring stitches.","sourceDate":"2011-08-13"},{"SOURCE_ROW_NUMBER":"165008","DOCUMENT_NO":"220112200032","ACCIDENT_DT":"06/28/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"127","NARRATIVE":"EE was walking around the head of the continuous miner when he hit his hard hat on a torque tension roof bolt, thus knocking his hard hat off of his head. He replaced the hard hat on his head and went back to work.   He continued to work up until his doctor took him off work on 07/29/2011.","sourceDate":"2011-06-28"},{"SOURCE_ROW_NUMBER":"113237","DOCUMENT_NO":"220102800009","ACCIDENT_DT":"09/28/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Taking a metal bar out of the center of a 1000 roll of belt, as the bar was being let down the bar fell on his middle finger on his left hand. This resulted in a fracture of the end of that finger.","sourceDate":"2010-09-28"},{"SOURCE_ROW_NUMBER":"134772","DOCUMENT_NO":"220102580007","ACCIDENT_DT":"09/10/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Had loaded a continuous miner on the lowboy, while taking the block off the stand, EE tripped the stand release and the stand came up and caught another ee left hand between frame and stand.","sourceDate":"2010-09-10"},{"SOURCE_ROW_NUMBER":"152117","DOCUMENT_NO":"220102560005","ACCIDENT_DT":"07/30/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"230","NARRATIVE":"EE was loading conveyor belt on a belt car and was using clamp (rope dog) to pull on the belt. The clamp slipped off the belt, causing an injury to his left shoulder. Possible rotary cup damage to shoulder.  He started missing work from this incident 09/07/2010.","sourceDate":"2010-07-30"},{"SOURCE_ROW_NUMBER":"169286","DOCUMENT_NO":"220102110023","ACCIDENT_DT":"07/13/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"51","NARRATIVE":"Employee kneeled down and hit his right knee on a rock, which twisted his knee. He said he felt something pop in his knee and pain in the left side of his right knee. He continued to work the rest of the shift. He has continued to work up till 7/29/10 and was taken off work after the MRI showed a torn meniscus in his right knee.","sourceDate":"2010-07-13"},{"SOURCE_ROW_NUMBER":"44525","DOCUMENT_NO":"220101660002","ACCIDENT_DT":"06/04/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Drill steel got stuck in top while drilling hole, trying to spin the drill steel down, when the head went up and caught hand between steel and the top. Had five stitches in right thumb.","sourceDate":"2010-06-04"},{"SOURCE_ROW_NUMBER":"96016","DOCUMENT_NO":"220100220012","ACCIDENT_DT":"01/13/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"In #5 entry at spad #839 EE was pulling a loose piece of rock off the right corner. The rock come down and pulled the hung miner cable down onto his head, causing pain in lower back.","sourceDate":"2010-01-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-08-13","lastDate":"2014-08-13","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":371,"firstDate":"2008-12-08","lastDate":"2013-04-08","metrics":{"ss":64,"delinquent":371,"recentRows":0,"paidPenalty":70788.29,"proposedPenalty":72776,"currentAssessment":71757},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1078817","VIOLATION_NO":"8256233","ISSUE_DT":"04/08/2013","CFR_STANDARD_CD":"72.520(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-08"},{"SOURCE_ROW_NUMBER":"1075387","VIOLATION_NO":"8246644","ISSUE_DT":"08/27/2012","CFR_STANDARD_CD":"75.1107-13(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-27"},{"SOURCE_ROW_NUMBER":"1075386","VIOLATION_NO":"8246633","ISSUE_DT":"08/20/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"687.00","CURRENT_ASSESSMENT_AMT":"515.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-08-20"},{"SOURCE_ROW_NUMBER":"1075362","VIOLATION_NO":"8246610","ISSUE_DT":"06/20/2012","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"1075361","VIOLATION_NO":"8246609","ISSUE_DT":"06/20/2012","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"1075360","VIOLATION_NO":"8246608","ISSUE_DT":"06/14/2012","CFR_STANDARD_CD":"75.1714-8(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1075359","VIOLATION_NO":"8246607","ISSUE_DT":"06/11/2012","CFR_STANDARD_CD":"77.402","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"1075358","VIOLATION_NO":"8246606","ISSUE_DT":"06/03/2012","CFR_STANDARD_CD":"75.1103-4(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-03"},{"SOURCE_ROW_NUMBER":"1075357","VIOLATION_NO":"8246605","ISSUE_DT":"05/29/2012","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-29"},{"SOURCE_ROW_NUMBER":"1075356","VIOLATION_NO":"8246601","ISSUE_DT":"05/15/2012","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"1075355","VIOLATION_NO":"8246600","ISSUE_DT":"05/15/2012","CFR_STANDARD_CD":"75.1101-8(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"1075354","VIOLATION_NO":"8246599","ISSUE_DT":"05/08/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":6,"firstDate":"2013-01-16","lastDate":"2013-05-02","metrics":{"appeals":0,"decisions":6,"recentRows":0,"decisionPenalty":2746,"originalPenalty":3765},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"92161","VIOLATION_NO":"8246633","DOCKET_NO":"KENT 2013-123","DECISION_DT":"05/02/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"515.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-05-02"},{"SOURCE_ROW_NUMBER":"321467","VIOLATION_NO":"8246447","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-04-29"},{"SOURCE_ROW_NUMBER":"321268","VIOLATION_NO":"8266026","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"873.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-04-29"},{"SOURCE_ROW_NUMBER":"321267","VIOLATION_NO":"8246446","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"240.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-04-29"},{"SOURCE_ROW_NUMBER":"84430","VIOLATION_NO":"8246451","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"200.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2013-04-29"},{"SOURCE_ROW_NUMBER":"321636","VIOLATION_NO":"8246454","DOCKET_NO":"KENT 2012-1159","DECISION_DT":"01/16/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"378.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-01-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":483,"firstDate":"2009-03-23","lastDate":"2012-06-20","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":64,"validSamples":419,"maxConcentration":5.626,"concentrationTotal":265.775},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1558078","CASS_NUM":"57979325","SMP_TAKEN_DT":"6/20/2012","CONC":".037","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"1436577","CASS_NUM":"57979338","SMP_TAKEN_DT":"6/7/2012","CONC":".379","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"752535","CASS_NUM":"57979332","SMP_TAKEN_DT":"6/7/2012","CONC":".317","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"500328","CASS_NUM":"57979203","SMP_TAKEN_DT":"6/7/2012","CONC":".076","SMP_TYPE_CD_DESC":"INVALID SAMPLE TYPE","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID SAMPLE TYPE","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"92878","CASS_NUM":"51130654","SMP_TAKEN_DT":"5/23/2012","CONC":".332","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-23"},{"SOURCE_ROW_NUMBER":"1235232","CASS_NUM":"51107758","SMP_TAKEN_DT":"5/10/2012","CONC":".34","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-10"},{"SOURCE_ROW_NUMBER":"1581394","CASS_NUM":"51130670","SMP_TAKEN_DT":"5/9/2012","CONC":".654","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-09"},{"SOURCE_ROW_NUMBER":"1366116","CASS_NUM":"51122238","SMP_TAKEN_DT":"5/9/2012","CONC":".29","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-09"},{"SOURCE_ROW_NUMBER":"1429255","CASS_NUM":"51130682","SMP_TAKEN_DT":"5/8/2012","CONC":".49","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-08"},{"SOURCE_ROW_NUMBER":"1067291","CASS_NUM":"51130694","SMP_TAKEN_DT":"5/8/2012","CONC":".024","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"UNREPRESENTATIVE SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-08"},{"SOURCE_ROW_NUMBER":"1606970","CASS_NUM":"57948741","SMP_TAKEN_DT":"5/7/2012","CONC":".071","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MECHANIC","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-07"},{"SOURCE_ROW_NUMBER":"1337770","CASS_NUM":"57948680","SMP_TAKEN_DT":"5/7/2012","CONC":"1.017","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2009-05-05","lastDate":"2010-02-18","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":6,"firstDate":"2012-01-11","lastDate":"2012-08-20","metrics":{"decisions":6,"ssChanged":0,"recentRows":0,"decisionPenalty":2746,"proposedPenalty":3765},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"86699","CITATION_NO":"8246633","CITATION_ISSUE_DT":"08/20/2012","DOCKET_NO":"KENT 2013-123","DECISION_DT":"05/02/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"515.00","sourceDate":"2012-08-20"},{"SOURCE_ROW_NUMBER":"253111","CITATION_NO":"8246454","CITATION_ISSUE_DT":"01/23/2012","DOCKET_NO":"KENT 2012-1159","DECISION_DT":"01/16/2013","CFR_STANDARD_CODE":"75.1722(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"378.00","sourceDate":"2012-01-23"},{"SOURCE_ROW_NUMBER":"82749","CITATION_NO":"8246451","CITATION_ISSUE_DT":"01/17/2012","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","CFR_STANDARD_CODE":"75.514","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"200.00","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"252142","CITATION_NO":"8266026","CITATION_ISSUE_DT":"01/13/2012","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"873.00","sourceDate":"2012-01-13"},{"SOURCE_ROW_NUMBER":"423232","CITATION_NO":"8246447","CITATION_ISSUE_DT":"01/11/2012","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","sourceDate":"2012-01-11"},{"SOURCE_ROW_NUMBER":"26199","CITATION_NO":"8246446","CITATION_ISSUE_DT":"01/11/2012","DOCKET_NO":"KENT 2012-824","DECISION_DT":"04/29/2013","CFR_STANDARD_CODE":"75.701","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"240.00","sourceDate":"2012-01-11"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":490,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":135,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2008-10-02","lastDate":"2008-10-02","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":68,"firstDate":"2008-10-27","lastDate":"2014-08-13","metrics":{"inspectors":112,"recentRows":0,"onSiteHours":2766.5,"inspectionHours":4026.75,"inspectionSamples":400},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"737459","EVENT_NO":"4204408","INSPECTION_BEGIN_DT":"08/13/2014","INSPECTION_END_DT":"08/13/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2014-08-13"},{"SOURCE_ROW_NUMBER":"271151","EVENT_NO":"4203937","INSPECTION_BEGIN_DT":"01/24/2014","INSPECTION_END_DT":"01/27/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2014-01-24"},{"SOURCE_ROW_NUMBER":"696971","EVENT_NO":"4203927","INSPECTION_BEGIN_DT":"11/18/2013","INSPECTION_END_DT":"12/11/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.75","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2013-11-18"},{"SOURCE_ROW_NUMBER":"344286","EVENT_NO":"4204015","INSPECTION_BEGIN_DT":"07/22/2013","INSPECTION_END_DT":"07/25/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2013-07-22"},{"SOURCE_ROW_NUMBER":"760391","EVENT_NO":"4203907","INSPECTION_BEGIN_DT":"04/16/2013","INSPECTION_END_DT":"06/05/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"22.25","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2013-04-16"},{"SOURCE_ROW_NUMBER":"258573","EVENT_NO":"4204064","INSPECTION_BEGIN_DT":"04/08/2013","INSPECTION_END_DT":"04/11/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2013-04-08"},{"SOURCE_ROW_NUMBER":"908082","EVENT_NO":"4203982","INSPECTION_BEGIN_DT":"03/20/2013","INSPECTION_END_DT":"03/20/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2013-03-20"},{"SOURCE_ROW_NUMBER":"239802","EVENT_NO":"4202745","INSPECTION_BEGIN_DT":"01/09/2013","INSPECTION_END_DT":"01/10/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2013-01-09"},{"SOURCE_ROW_NUMBER":"1041775","EVENT_NO":"6392372","INSPECTION_BEGIN_DT":"10/17/2012","INSPECTION_END_DT":"11/16/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17.5","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"773327","EVENT_NO":"4203788","INSPECTION_BEGIN_DT":"07/19/2012","INSPECTION_END_DT":"07/19/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2012-07-19"},{"SOURCE_ROW_NUMBER":"687915","EVENT_NO":"4202732","INSPECTION_BEGIN_DT":"07/05/2012","INSPECTION_END_DT":"09/20/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"62.5","SUM_TOTAL_ON_SITE_HOURS":"43.75","sourceDate":"2012-07-05"},{"SOURCE_ROW_NUMBER":"229540","EVENT_NO":"4203762","INSPECTION_BEGIN_DT":"06/01/2012","INSPECTION_END_DT":"06/01/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6.25","sourceDate":"2012-06-01"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":38,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013-Q2":{"hours":0,"employees":0,"production":0},"2013-Q1":{"hours":0,"employees":0,"production":0},"2012-Q4":{"hours":3299,"employees":9,"production":0},"2012-Q3":{"hours":6470,"employees":9,"production":0},"2012-Q2":{"hours":27572,"employees":42,"production":43812},"2012-Q1":{"hours":31583,"employees":44,"production":48321},"2011-Q4":{"hours":40747,"employees":64,"production":56773},"2011-Q3":{"hours":47526,"employees":73,"production":70791},"2011-Q2":{"hours":49564,"employees":73,"production":76661},"2011-Q1":{"hours":50702,"employees":73,"production":69295},"2010-Q4":{"hours":46714,"employees":66,"production":77536},"2010-Q3":{"hours":45270,"employees":62,"production":71550}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":1172,"employees":16,"production":0},"2009":{"hours":126117,"employees":53,"production":237841},"2010":{"hours":174028,"employees":61,"production":300400},"2011":{"hours":188539,"employees":71,"production":273520},"2012":{"hours":68924,"employees":27,"production":92133}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":47,"firstDate":"2009-05-20","lastDate":"2012-06-20","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":2409,"pelDoseTotal":1760},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"100533","EVENT_NO":"4202727","SURVEY_DATE":"06/20/2012","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"78","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"100536","EVENT_NO":"4202727","SURVEY_DATE":"06/07/2012","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"32","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"100535","EVENT_NO":"4202727","SURVEY_DATE":"06/07/2012","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"28","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"100534","EVENT_NO":"4202727","SURVEY_DATE":"06/07/2012","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2012-06-07"},{"SOURCE_ROW_NUMBER":"100541","EVENT_NO":"4203076","SURVEY_DATE":"01/04/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"78","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"100540","EVENT_NO":"4203076","SURVEY_DATE":"01/04/2012","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"80","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"100539","EVENT_NO":"4203076","SURVEY_DATE":"01/04/2012","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"018","ACT_DOSE_85":"25","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"100538","EVENT_NO":"4203076","SURVEY_DATE":"01/04/2012","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"113","PEL_DOSE_90":"90","SURVEY_TYPE":"I","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"100537","EVENT_NO":"4203076","SURVEY_DATE":"01/04/2012","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"018","ACT_DOSE_85":"118","PEL_DOSE_90":"107","SURVEY_TYPE":"I","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"100532","EVENT_NO":"4202692","SURVEY_DATE":"09/20/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"62","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2011-09-20"},{"SOURCE_ROW_NUMBER":"100531","EVENT_NO":"4202692","SURVEY_DATE":"09/20/2011","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"39","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2011-09-20"},{"SOURCE_ROW_NUMBER":"100506","EVENT_NO":"4191845","SURVEY_DATE":"10/19/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"33","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2010-10-19"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":34,"firstDate":"2009-05-14","lastDate":"2012-05-07","metrics":{"recentRows":0,"voidSamples":5,"maxQuartzPct":15.7,"validSamples":29,"quartzPctTotal":180.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"164771","CASSETTE_NO":"57948680","SAMPLE_DT":"05/07/2012","QUARTZ_PCT":"02.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-05-07"},{"SOURCE_ROW_NUMBER":"25683","CASSETTE_NO":"57948737","SAMPLE_DT":"05/07/2012","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-05-07"},{"SOURCE_ROW_NUMBER":"80164","CASSETTE_NO":"51130681","SAMPLE_DT":"03/23/2012","QUARTZ_PCT":"09.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-23"},{"SOURCE_ROW_NUMBER":"14750","CASSETTE_NO":"57948662","SAMPLE_DT":"03/05/2012","QUARTZ_PCT":"09.2","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-05"},{"SOURCE_ROW_NUMBER":"150792","CASSETTE_NO":"51130629","SAMPLE_DT":"12/23/2011","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2011-12-23"},{"SOURCE_ROW_NUMBER":"18716","CASSETTE_NO":"57938031","SAMPLE_DT":"12/06/2011","QUARTZ_PCT":"15.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-06"},{"SOURCE_ROW_NUMBER":"143275","CASSETTE_NO":"51107752","SAMPLE_DT":"11/01/2011","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-11-01"},{"SOURCE_ROW_NUMBER":"956","CASSETTE_NO":"51107756","SAMPLE_DT":"08/26/2011","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2011-08-26"},{"SOURCE_ROW_NUMBER":"50898","CASSETTE_NO":"51122251","SAMPLE_DT":"08/03/2011","QUARTZ_PCT":"10.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-03"},{"SOURCE_ROW_NUMBER":"153027","CASSETTE_NO":"51078467","SAMPLE_DT":"03/04/2011","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2011-03-04"},{"SOURCE_ROW_NUMBER":"84966","CASSETTE_NO":"57907435","SAMPLE_DT":"02/09/2011","QUARTZ_PCT":"08.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-09"},{"SOURCE_ROW_NUMBER":"105968","CASSETTE_NO":"57907451","SAMPLE_DT":"01/20/2011","QUARTZ_PCT":"02.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":378,"firstDate":"2008-12-08","lastDate":"2013-04-08","metrics":{"ss":64,"amountDue":71757,"contested":0,"amountPaid":70788.29,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":72776},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1145422","VIOLATION_NO":"8256233","VIOLATION_ISSUE_DT":"04/08/2013","SIG_SUB":"N","PART_SECTION":"72.520(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/11/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-04-08"},{"SOURCE_ROW_NUMBER":"1145526","VIOLATION_NO":"8246644","VIOLATION_ISSUE_DT":"08/27/2012","SIG_SUB":"N","PART_SECTION":"75.1107-13(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/04/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-08-27"},{"SOURCE_ROW_NUMBER":"1145525","VIOLATION_NO":"8246633","VIOLATION_ISSUE_DT":"08/20/2012","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/20/2012","PROPOSED_PENALTY":"687","AMOUNT_DUE":"515","AMOUNT_PAID":"515","CONTESTED_IND":"N","sourceDate":"2012-08-20"},{"SOURCE_ROW_NUMBER":"1145421","VIOLATION_NO":"8246610","VIOLATION_ISSUE_DT":"06/20/2012","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"1145420","VIOLATION_NO":"8246609","VIOLATION_ISSUE_DT":"06/20/2012","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2012-06-20"},{"SOURCE_ROW_NUMBER":"1145419","VIOLATION_NO":"8246608","VIOLATION_ISSUE_DT":"06/14/2012","SIG_SUB":"N","PART_SECTION":"75.1714-8(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/19/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-14"},{"SOURCE_ROW_NUMBER":"1145418","VIOLATION_NO":"8246607","VIOLATION_ISSUE_DT":"06/11/2012","SIG_SUB":"N","PART_SECTION":"77.402","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/11/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-11"},{"SOURCE_ROW_NUMBER":"1145417","VIOLATION_NO":"8246606","VIOLATION_ISSUE_DT":"06/03/2012","SIG_SUB":"N","PART_SECTION":"75.1103-4(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/04/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-03"},{"SOURCE_ROW_NUMBER":"1145416","VIOLATION_NO":"8246605","VIOLATION_ISSUE_DT":"05/29/2012","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/29/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-05-29"},{"SOURCE_ROW_NUMBER":"1145415","VIOLATION_NO":"8246601","VIOLATION_ISSUE_DT":"05/15/2012","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2012","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"1145414","VIOLATION_NO":"8246600","VIOLATION_ISSUE_DT":"05/15/2012","SIG_SUB":"N","PART_SECTION":"75.1101-8(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2012","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2012-05-15"},{"SOURCE_ROW_NUMBER":"1145413","VIOLATION_NO":"8246599","VIOLATION_ISSUE_DT":"05/08/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/10/2012","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2012-05-08"}]}],"safety":{"href":"/api/v1/mines/1519323/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519323/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Diesel equipment inventory.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-D/section-72.520","part":"72","subchapter":"O","subpart":"D","id":"72.520","citation":"30 CFR 72.520","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-13","heading":"Approval of other fire suppression devices.","id":"75.1107-13","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-13","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Notwithstanding the provisions of §§ 75.1107-1 through 75.1107-12 the District Manager for the District in which the mine is located may approve any other fire suppression system or device which provides substantially equivalent protection as would be achieved through compliance with those sections: Provided, That no such system or device shall be approved which does not meet the following minimum criteria:\n\n(a) Components shall be approved by the Secretary, or where appropriate be listed as approved by a nationally recognized agency approved by the Secretary.\n\n(b) The fire suppression equipment shall be designed to withstand the rigors of the mine environment. Where used, pressure vessels shall conform with the requirements of section 3603, 3606, 3607, 3707, and 3708 of National Fire Code No. 22 “Water Tanks for Private Fire Protection” (NFPA No. 22-1971).\n\n(c) The cover of hose of fire suppression devices, if used on the protected equipment, shall meet the flame-resistant requirements of Part 18 of this chapter (Bureau of Mines Schedule 2G).\n\n(d) Extinguishing agents shall not create a serious toxic or other hazard to the miners.\n\n(e) The electrical components of the fire suppression device shall meet the requirements for electrical components of the mining machine.\n\n(f) Where used, manual actuators for initiating the operation of the fire suppression device shall be readily accessible to the machine operator. On unattended equipment, an automatic as well as a manual actuator shall be provided.\n\n(g) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(h) On unattended equipment, the sensor system shall have a means for checking its operative condition.\n\n(i) The fire suppression agent shall be directed at locations where the greatest potential fire hazard exists. Cable reel compartments shall receive approximately twice the quantity of extinguishing agent as each other hazardous location.\n\n(j) The rate of application of the fire suppression agent shall minimize the time for quenching and the total quantity applied shall be sufficient to quench a fire in its incipient stage.\n\n(k) The effectiveness of the quenching agent, together with the total quantity of agent and its rate of application shall provide equivalent protection to the water, dry powder, or foam systems described in §§ 75.1107-7, 75.1107-9, and 75.1107-10.\n\n(l) The fire suppression device shall be operable at all times electrical power is connected to the mining machine, except during tramming when the machine is in a ventilated passageway, the water hose if used, may be switched from one hydrant to another in a reasonable time and except in systems meeting the minimum special criteria set forth in paragraph (m) of this section.\n\n(m) Systems for attended equipment which are not continuously connected to a water supply shall not be approved unless they meet the following minimum criteria:\n\n(1) The machine shall be equipped with a firehose at least 50 feet in length which is continuously connected to the machine-mounted portion of the system.\n\n(2) Hydrants in proximity to the area where the machine is to be used shall be equipped with sufficient hose to reach the machine at any time it is connected to a power source.\n\n(3) The machine shall be used only where the operator (or other person) will always be in ventilated air uncontaminated by smoke and hot gases from the machine fire while extending the machine-mounted hose to connect with the hydrant-mounted hose.\n\n(4) The machine and hydrant hoses shall be readily accessible so that the connection between the machine-mounted hose and the hydrant hose can be made and water flow achieved in not more than 3 minutes under actual mining conditions for any location of the machine while electric power is connected.\n\n(5) The rate of water flow at the machine shall provide a minimum of 0.12 gallon of water per minute per square foot of top surface area (excluding conveyors, cutters, and gathering heads). The water shall discharge to all hazardous locations on the machine.\n\n(6) Hose, if used on the machine, in addition to meeting the flame resistant requirements for the cover of a hose provided in §§ 75.1107-3(b) and 75.1107-13(c) shall have a minimum burst pressure 4 times that of the static water pressure at the mining machine. Fabric braid hose shall have at least two braids, and wire braid hose shall have at least a single braid.\n\n(7) In addition to the hose located at the hydrant (which is intended to be connected to the hose on the machine) the firefighting equipment required by § 75.1100-2(a) shall be maintained.\n\n(8) A sufficient number of trained miners shall be kept on the section when the machine is in use to connect the machine hose to the hydrant hose and achieve water flow in not more than 3 minutes.\n\n[37 FR 15303, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","heading":"Reporting SCSR inventory and malfunctions; retention of SCSRs.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-8","part":"75","subchapter":"O","subpart":"R","id":"75.1714-8","citation":"30 CFR 75.1714-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Hand-held power tools; safety devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.402","part":"77","subchapter":"O","subpart":"E","id":"77.402","citation":"30 CFR 77.402","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Water sprinkler systems; arrangement of sprinklers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101-8","part":"75","subchapter":"O","subpart":"L","id":"75.1101-8","citation":"30 CFR 75.1101-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519323","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}