{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519318","name":"D-1 Garmeada #2","status":"Abandoned","status_date":"2023-11-02","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Bell","nearest_town":"Middlesboro","operator_id":"0100767","operator_name":"Revelation Energy, LLC","controller_id":"C15863","controller_name":"Jeffery A  Hoops","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.619722,"longitude":-83.879722},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":5902},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519318","name":"D-1 Garmeada #2"},"operator":{"type":"operator","id":"0100767","name":"Revelation Energy, LLC"},"controller":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1519318","name":"D-1 Garmeada #2"},"validFrom":"1988-09-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519318|C13562|1988-09-28|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19841","name":"Bell County Coal Corporation"},"object":{"type":"mine","id":"1519318","name":"D-1 Garmeada #2"},"validFrom":"2009-01-23","validTo":"2014-12-29","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519318|P19841|2009-01-23|2014-12-29"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19841","name":"Bell County Coal Corporation"},"validFrom":"2009-01-23","validTo":"2014-12-29","current":false,"derived":true,"evidenceMineId":"1519318","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519318|P19841|2009-01-23|C13562|1988-09-28|90356"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"mine","id":"1519318","name":"D-1 Garmeada #2"},"validFrom":"2009-05-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519318|C15863|2009-05-08|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0100767","name":"Revelation Energy, LLC"},"object":{"type":"mine","id":"1519318","name":"D-1 Garmeada #2"},"validFrom":"2014-12-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519318|0100767|2014-12-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"operator","id":"0100767","name":"Revelation Energy, LLC"},"validFrom":"2014-12-30","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519318","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519318|0100767|2014-12-30|C15863|2009-05-08|97235"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":20,"firstDate":"2009-05-26","lastDate":"2017-08-14","metrics":{"daysLost":591,"injuries":14,"fatalities":0,"recentRows":0,"restrictedDays":99,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"268228","DOCUMENT_NO":"220172410017","ACCIDENT_DT":"08/14/2017","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"162","NARRATIVE":"EE was hauling coal, hit a hole and bounced into the canopy. The mining car was not loaded. EE stove up their neck, they went to ER and CT was negative for anything broken. EE was referred to see family physician to schedule MRI. EE has an MRI scheduled and is to remain off work until seeing doctor for MRI results.","sourceDate":"2017-08-14"},{"SOURCE_ROW_NUMBER":"91771","DOCUMENT_NO":"220171320021","ACCIDENT_DT":"05/10/2017","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Scoop tram operator, Load/Haul/Dump operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was loading oxygen tank in truck. A piece of metal was sticking up on tailgate of truck. Employee let tank down, finger was between metal & tank. Employee received cut to middle finger on left hand. Finger nail was removed by ER doctor & x-rays showed fracture to tip of the finger. Employee returned to work next day, no loss of time.","sourceDate":"2017-05-10"},{"SOURCE_ROW_NUMBER":"225195","DOCUMENT_NO":"220170660016","ACCIDENT_DT":"03/06/2017","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"A roof fall occurred on the retreat mining section briefly catching the MRS unit.  MSHA was contacted, an action plan submitted and the MRS was retrieved. There was no one injured and ventilation was not affected.  The MRS was not damaged.","sourceDate":"2017-03-06"},{"SOURCE_ROW_NUMBER":"251104","DOCUMENT_NO":"220162510017","ACCIDENT_DT":"08/29/2016","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"Employee was cutting skirt rubber for tail piece when ee picked up belt ee felt tingling in arm.","sourceDate":"2016-08-29"},{"SOURCE_ROW_NUMBER":"208015","DOCUMENT_NO":"220150830018","ACCIDENT_DT":"03/16/2015","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"15' wide x 8' high x 8' deep Roof fall by fan house #3 portal","sourceDate":"2015-03-16"},{"SOURCE_ROW_NUMBER":"263989","DOCUMENT_NO":"220141700047","ACCIDENT_DT":"06/09/2014","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Wireman, Communications man","NO_INJURIES":"1","DAYS_LOST":"84","NARRATIVE":"Employee stated that he was cleaning up the pad and side walk outside the mine office.  He stated that he was picking up small roll of belt and felt a sharp pain in his lower back.  He was transported to the hospital and was treated for a pulled muscle and became a lost time accident.","sourceDate":"2014-06-09"},{"SOURCE_ROW_NUMBER":"57384","DOCUMENT_NO":"220141540016","ACCIDENT_DT":"05/19/2014","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"On May 19th 2013 the company was contacted by letter stating that a medical examination of employee indicates he has pneumoconiosis.  On May 30th employee indicated in writing that he was not exercising his rights under part 90 at this time.","sourceDate":"2014-05-19"},{"SOURCE_ROW_NUMBER":"117530","DOCUMENT_NO":"220133540030","ACCIDENT_DT":"12/02/2013","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"17","NARRATIVE":"Employee stated that he and the section mechanic were lifting the miner cable up to hang it across an intersection when he felt a sharp pain in his right shoulder.  Employee continued to work until 12-18-2013 when he had surgery to the shoulder.","sourceDate":"2013-12-02"},{"SOURCE_ROW_NUMBER":"177933","DOCUMENT_NO":"220132210013","ACCIDENT_DT":"07/19/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"61","NARRATIVE":"Employee was helping move a booster pump when he felt a sharp pain in his back.  He continued to work until August 1st when he became a lost time injury.","sourceDate":"2013-07-19"},{"SOURCE_ROW_NUMBER":"220953","DOCUMENT_NO":"220131360027","ACCIDENT_DT":"05/13/2013","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"The mine has experienced an unplanned roof fall in the 1st East Submains. The fall extent is unknown.  It is inby the BMP #2 across the crosscut 3 and 2 and in the #4 entry.  Test holes and timbers that have been installed for sometime remain unchanged.  The fall did not affect persons, ventilation nor equipment.  The fall will not be cleaned up.","sourceDate":"2013-05-13"},{"SOURCE_ROW_NUMBER":"147843","DOCUMENT_NO":"220130880008","ACCIDENT_DT":"03/08/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"40","NARRATIVE":"Employee was working on construction of an overcast when part of the wall fell causing the constructed portion of the overcast to fall injuring employees left knee.  Employee was diagnosed with a torn meniscus on 3-18-12 and became a lost time accident at that time.","sourceDate":"2013-03-08"},{"SOURCE_ROW_NUMBER":"48879","DOCUMENT_NO":"220122760033","ACCIDENT_DT":"09/19/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","DAYS_LOST":"23","NARRATIVE":"Unloading Hydraulic oil","sourceDate":"2012-09-19"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2023-11-02","lastDate":"2023-11-02","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":1190,"firstDate":"2009-05-27","lastDate":"2021-04-30","metrics":{"ss":335,"delinquent":825,"recentRows":3,"paidPenalty":232809.78,"proposedPenalty":411094,"currentAssessment":342184},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1968567","VIOLATION_NO":"9234334","ISSUE_DT":"04/30/2021","CFR_STANDARD_CD":"48.23(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"139.00","CURRENT_ASSESSMENT_AMT":"139.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2021-04-30"},{"SOURCE_ROW_NUMBER":"1968566","VIOLATION_NO":"9234333","ISSUE_DT":"04/30/2021","CFR_STANDARD_CD":"75.1711-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"139.00","CURRENT_ASSESSMENT_AMT":"139.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2021-04-30"},{"SOURCE_ROW_NUMBER":"1968565","VIOLATION_NO":"9234332","ISSUE_DT":"04/30/2021","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"139.00","CURRENT_ASSESSMENT_AMT":"139.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2021-04-30"},{"SOURCE_ROW_NUMBER":"2000483","VIOLATION_NO":"8372410","ISSUE_DT":"10/11/2017","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"259.00","CURRENT_ASSESSMENT_AMT":"259.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"2000482","VIOLATION_NO":"8372409","ISSUE_DT":"10/11/2017","CFR_STANDARD_CD":"75.333(b)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"148.00","CURRENT_ASSESSMENT_AMT":"148.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"2000481","VIOLATION_NO":"8372408","ISSUE_DT":"10/11/2017","CFR_STANDARD_CD":"75.606","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"734.00","CURRENT_ASSESSMENT_AMT":"250.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"2000480","VIOLATION_NO":"8372407","ISSUE_DT":"10/10/2017","CFR_STANDARD_CD":"75.1107-9(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"148.00","CURRENT_ASSESSMENT_AMT":"148.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"2000479","VIOLATION_NO":"8372406","ISSUE_DT":"10/10/2017","CFR_STANDARD_CD":"75.606","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"148.00","CURRENT_ASSESSMENT_AMT":"148.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"2000478","VIOLATION_NO":"8372405","ISSUE_DT":"10/10/2017","CFR_STANDARD_CD":"75.1505(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"116.00","CURRENT_ASSESSMENT_AMT":"116.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"2000477","VIOLATION_NO":"8372404","ISSUE_DT":"10/05/2017","CFR_STANDARD_CD":"75.351(c)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"188.00","CURRENT_ASSESSMENT_AMT":"188.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-05"},{"SOURCE_ROW_NUMBER":"2000476","VIOLATION_NO":"8372403","ISSUE_DT":"10/05/2017","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"220.00","CURRENT_ASSESSMENT_AMT":"220.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-05"},{"SOURCE_ROW_NUMBER":"2000475","VIOLATION_NO":"8372402","ISSUE_DT":"10/05/2017","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1096.00","CURRENT_ASSESSMENT_AMT":"600.00","ASSESS_CASE_STATUS_CD":"Received","sourceDate":"2017-10-05"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":650,"firstDate":"2011-03-25","lastDate":"2018-08-06","metrics":{"appeals":0,"decisions":650,"recentRows":0,"decisionPenalty":183750,"originalPenalty":254004},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"399035","VIOLATION_NO":"8372401","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"734.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"399034","VIOLATION_NO":"8372396","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"734.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"398864","VIOLATION_NO":"8372400","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"148.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"398863","VIOLATION_NO":"8372397","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"734.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"398616","VIOLATION_NO":"8372399","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"148.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"398615","VIOLATION_NO":"8372398","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"420.00","DECISION_PENALTY_AMT":"420.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"398030","VIOLATION_NO":"8372410","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"259.00","DECISION_PENALTY_AMT":"259.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"398029","VIOLATION_NO":"8372404","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"188.00","DECISION_PENALTY_AMT":"188.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"131132","VIOLATION_NO":"8372407","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"148.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"131131","VIOLATION_NO":"8372403","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"220.00","DECISION_PENALTY_AMT":"220.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"131130","VIOLATION_NO":"8372402","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1096.00","DECISION_PENALTY_AMT":"600.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"},{"SOURCE_ROW_NUMBER":"130855","VIOLATION_NO":"8372408","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"250.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2018-08-06"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1377,"firstDate":"2009-06-03","lastDate":"2020-02-04","metrics":{"recentRows":0,"cpdmSamples":258,"voidSamples":306,"validSamples":1071,"maxConcentration":28.335,"concentrationTotal":689.698},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"597866","CASS_NUM":"51043490","SMP_TAKEN_DT":"2/4/2020","CONC":"1.033","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2020-02-04"},{"SOURCE_ROW_NUMBER":"638397","CASS_NUM":"58311361","SMP_TAKEN_DT":"10/17/2017","CONC":".027","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"DISPATCHER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2017-10-17"},{"SOURCE_ROW_NUMBER":"2275758","SMP_TAKEN_DT":"10/12/2017","CONC":".42","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-12"},{"SOURCE_ROW_NUMBER":"2274825","SMP_TAKEN_DT":"10/12/2017","CONC":".534","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-12"},{"SOURCE_ROW_NUMBER":"2190450","SMP_TAKEN_DT":"10/11/2017","CONC":".391","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"1849843","SMP_TAKEN_DT":"10/11/2017","CONC":".416","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"2615745","SMP_TAKEN_DT":"10/10/2017","CONC":".477","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"2190628","SMP_TAKEN_DT":"10/10/2017","CONC":".452","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"2189236","SMP_TAKEN_DT":"10/9/2017","CONC":".179","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-09"},{"SOURCE_ROW_NUMBER":"1934367","SMP_TAKEN_DT":"10/9/2017","CONC":".629","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-10-09"},{"SOURCE_ROW_NUMBER":"2275650","SMP_TAKEN_DT":"9/8/2017","CONC":".098","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-09-08"},{"SOURCE_ROW_NUMBER":"2701607","SMP_TAKEN_DT":"9/7/2017","CONC":".218","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CPDM","sourceDate":"2017-09-07"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":17,"firstDate":"2013-05-09","lastDate":"2014-11-04","metrics":{"linkedIssuances":17},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":650,"firstDate":"2009-08-18","lastDate":"2017-10-12","metrics":{"decisions":650,"ssChanged":72,"recentRows":0,"decisionPenalty":183750,"proposedPenalty":254004},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"7727","CITATION_NO":"9868404","CITATION_ISSUE_DT":"10/12/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"70.208(a)(2)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"220.00","DECISION_PENALTY_AMT":"220.00","sourceDate":"2017-10-12"},{"SOURCE_ROW_NUMBER":"383844","CITATION_NO":"8372409","CITATION_ISSUE_DT":"10/11/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.333(b)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"148.00","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"267468","CITATION_NO":"8372410","CITATION_ISSUE_DT":"10/11/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"259.00","DECISION_PENALTY_AMT":"259.00","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"157202","CITATION_NO":"8372408","CITATION_ISSUE_DT":"10/11/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.606","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"250.00","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"380788","CITATION_NO":"8372405","CITATION_ISSUE_DT":"10/10/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.1505(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"116.00","DECISION_PENALTY_AMT":"116.00","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"326905","CITATION_NO":"8372407","CITATION_ISSUE_DT":"10/10/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.1107-9(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"148.00","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"326904","CITATION_NO":"8372406","CITATION_ISSUE_DT":"10/10/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.606","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"148.00","DECISION_PENALTY_AMT":"148.00","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"440203","CITATION_NO":"8372402","CITATION_ISSUE_DT":"10/05/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1096.00","DECISION_PENALTY_AMT":"600.00","sourceDate":"2017-10-05"},{"SOURCE_ROW_NUMBER":"437788","CITATION_NO":"8372404","CITATION_ISSUE_DT":"10/05/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.351(c)(4)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"188.00","DECISION_PENALTY_AMT":"188.00","sourceDate":"2017-10-05"},{"SOURCE_ROW_NUMBER":"99763","CITATION_NO":"8372403","CITATION_ISSUE_DT":"10/05/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"220.00","DECISION_PENALTY_AMT":"220.00","sourceDate":"2017-10-05"},{"SOURCE_ROW_NUMBER":"380787","CITATION_NO":"8372401","CITATION_ISSUE_DT":"10/04/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.904","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"734.00","sourceDate":"2017-10-04"},{"SOURCE_ROW_NUMBER":"325447","CITATION_NO":"8372397","CITATION_ISSUE_DT":"10/04/2017","DOCKET_NO":"KENT 2018-0069","DECISION_DT":"08/06/2018","CFR_STANDARD_CODE":"75.1713-7(a)(3)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"734.00","DECISION_PENALTY_AMT":"734.00","sourceDate":"2017-10-04"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":206,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":34,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2009-01-23","lastDate":"2014-12-30","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":103,"firstDate":"2009-04-16","lastDate":"2023-09-21","metrics":{"inspectors":379,"recentRows":11,"onSiteHours":7365.5,"inspectionHours":12072,"inspectionSamples":1512},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"109595","EVENT_NO":"7045804","INSPECTION_BEGIN_DT":"09/21/2023","INSPECTION_END_DT":"09/21/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.25","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2023-09-21"},{"SOURCE_ROW_NUMBER":"935850","EVENT_NO":"7045700","INSPECTION_BEGIN_DT":"04/18/2023","INSPECTION_END_DT":"04/18/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2023-04-18"},{"SOURCE_ROW_NUMBER":"1097487","EVENT_NO":"7020237","INSPECTION_BEGIN_DT":"01/25/2023","INSPECTION_END_DT":"01/25/2023","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2023-01-25"},{"SOURCE_ROW_NUMBER":"11310","EVENT_NO":"7020230","INSPECTION_BEGIN_DT":"12/12/2022","INSPECTION_END_DT":"12/12/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2022-12-12"},{"SOURCE_ROW_NUMBER":"473179","EVENT_NO":"7020213","INSPECTION_BEGIN_DT":"08/29/2022","INSPECTION_END_DT":"08/29/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2022-08-29"},{"SOURCE_ROW_NUMBER":"529277","EVENT_NO":"6412736","INSPECTION_BEGIN_DT":"06/27/2022","INSPECTION_END_DT":"06/27/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2022-06-27"},{"SOURCE_ROW_NUMBER":"790716","EVENT_NO":"6412542","INSPECTION_BEGIN_DT":"03/23/2022","INSPECTION_END_DT":"03/23/2022","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2022-03-23"},{"SOURCE_ROW_NUMBER":"866189","EVENT_NO":"6412466","INSPECTION_BEGIN_DT":"10/05/2021","INSPECTION_END_DT":"10/05/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2021-10-05"},{"SOURCE_ROW_NUMBER":"91144","EVENT_NO":"6412524","INSPECTION_BEGIN_DT":"09/21/2021","INSPECTION_END_DT":"09/21/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2021-09-21"},{"SOURCE_ROW_NUMBER":"177705","EVENT_NO":"6412458","INSPECTION_BEGIN_DT":"06/24/2021","INSPECTION_END_DT":"06/24/2021","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2021-06-24"},{"SOURCE_ROW_NUMBER":"282962","EVENT_NO":"6412501","INSPECTION_BEGIN_DT":"04/30/2021","INSPECTION_END_DT":"05/11/2021","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"19.75","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2021-04-30"},{"SOURCE_ROW_NUMBER":"153227","EVENT_NO":"4453440","INSPECTION_BEGIN_DT":"10/04/2017","INSPECTION_END_DT":"10/10/2017","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2017-10-04"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":89,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2017-Q4":{"hours":12889,"employees":26,"production":3396},"2017-Q3":{"hours":20933,"employees":34,"production":33885},"2017-Q2":{"hours":20933,"employees":34,"production":34488},"2017-Q1":{"hours":18448,"employees":36,"production":52363},"2016-Q4":{"hours":19156,"employees":34,"production":37405},"2016-Q3":{"hours":40223,"employees":54,"production":69399},"2016-Q2":{"hours":34935,"employees":45,"production":73120},"2016-Q1":{"hours":33564,"employees":49,"production":70552},"2015-Q4":{"hours":31082,"employees":49,"production":56356},"2015-Q3":{"hours":33653,"employees":49,"production":69151},"2015-Q2":{"hours":29051,"employees":43,"production":55110},"2015-Q1":{"hours":27905,"employees":50,"production":78145}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":22,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009":{"hours":38865,"employees":26,"production":73852},"2010":{"hours":65237,"employees":30,"production":131276},"2011":{"hours":89314,"employees":39,"production":170925},"2012":{"hours":128409,"employees":54,"production":216956},"2013":{"hours":134463,"employees":72,"production":300215},"2014":{"hours":130015,"employees":62,"production":249210},"2015":{"hours":121691,"employees":49,"production":258762},"2016":{"hours":127878,"employees":46,"production":250476},"2017":{"hours":73203,"employees":35,"production":124132}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":250,"firstDate":"2009-06-23","lastDate":"2017-10-17","metrics":{"recentRows":0,"doseOver100":15,"actDoseTotal":11121,"pelDoseTotal":7415},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"100453","EVENT_NO":"6431612","SURVEY_DATE":"10/17/2017","OCCUPATION_CD_DESC":"AUGER (JACK SETTER) (INTAKE SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"45","PEL_DOSE_90":"33","SURVEY_TYPE":"I","sourceDate":"2017-10-17"},{"SOURCE_ROW_NUMBER":"100452","EVENT_NO":"6431612","SURVEY_DATE":"10/17/2017","OCCUPATION_CD_DESC":"AUGER (JACK SETTER) (INTAKE SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"039","ACT_DOSE_85":"20","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2017-10-17"},{"SOURCE_ROW_NUMBER":"100451","EVENT_NO":"6431612","SURVEY_DATE":"10/17/2017","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2017-10-17"},{"SOURCE_ROW_NUMBER":"100438","EVENT_NO":"6431549","SURVEY_DATE":"07/14/2017","OCCUPATION_CD_DESC":"SUPERINTENDENT","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"13","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2017-07-14"},{"SOURCE_ROW_NUMBER":"100437","EVENT_NO":"6431549","SURVEY_DATE":"07/14/2017","OCCUPATION_CD_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"5","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2017-07-14"},{"SOURCE_ROW_NUMBER":"100436","EVENT_NO":"6431549","SURVEY_DATE":"07/08/2017","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"54","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2017-07-08"},{"SOURCE_ROW_NUMBER":"100435","EVENT_NO":"6431549","SURVEY_DATE":"07/08/2017","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"51","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2017-07-08"},{"SOURCE_ROW_NUMBER":"100434","EVENT_NO":"6431549","SURVEY_DATE":"07/08/2017","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"65","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2017-07-08"},{"SOURCE_ROW_NUMBER":"100433","EVENT_NO":"6431549","SURVEY_DATE":"07/08/2017","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"68","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2017-07-08"},{"SOURCE_ROW_NUMBER":"100432","EVENT_NO":"6431549","SURVEY_DATE":"07/08/2017","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"68","PEL_DOSE_90":"56","SURVEY_TYPE":"I","sourceDate":"2017-07-08"},{"SOURCE_ROW_NUMBER":"100431","EVENT_NO":"6431542","SURVEY_DATE":"04/20/2017","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"18","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2017-04-20"},{"SOURCE_ROW_NUMBER":"100430","EVENT_NO":"6431542","SURVEY_DATE":"04/20/2017","OCCUPATION_CD_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"2","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2017-04-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":67,"firstDate":"2009-09-01","lastDate":"2017-07-08","metrics":{"recentRows":0,"voidSamples":6,"maxQuartzPct":9,"validSamples":61,"quartzPctTotal":337.6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"103771","CASSETTE_NO":"58284446","SAMPLE_DT":"07/08/2017","QUARTZ_PCT":"04.9","QUARTZ_MICROGRAMS":"30","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-07-08"},{"SOURCE_ROW_NUMBER":"50455","CASSETTE_NO":"58284449","SAMPLE_DT":"07/08/2017","QUARTZ_PCT":"06.9","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-07-08"},{"SOURCE_ROW_NUMBER":"143964","CASSETTE_NO":"58284614","SAMPLE_DT":"04/06/2017","QUARTZ_PCT":"05.3","QUARTZ_MICROGRAMS":"10","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-04-06"},{"SOURCE_ROW_NUMBER":"85530","CASSETTE_NO":"58284623","SAMPLE_DT":"04/06/2017","QUARTZ_PCT":"05.0","QUARTZ_MICROGRAMS":"7","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-04-06"},{"SOURCE_ROW_NUMBER":"125777","CASSETTE_NO":"58267129","SAMPLE_DT":"01/26/2017","QUARTZ_PCT":"05.5","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-01-26"},{"SOURCE_ROW_NUMBER":"72708","CASSETTE_NO":"58267242","SAMPLE_DT":"01/26/2017","QUARTZ_PCT":"03.8","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","SAMPLE_TYPE_DESC":"NON DESIGNATED OCCUPATION","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","sourceDate":"2017-01-26"},{"SOURCE_ROW_NUMBER":"36964","CASSETTE_NO":"58267134","SAMPLE_DT":"01/13/2017","QUARTZ_PCT":"01.8","QUARTZ_MICROGRAMS":"4","OCC_CODE_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2017-01-13"},{"SOURCE_ROW_NUMBER":"58747","CASSETTE_NO":"58240969","SAMPLE_DT":"07/06/2016","QUARTZ_PCT":"01.7","QUARTZ_MICROGRAMS":"6","OCC_CODE_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-07-06"},{"SOURCE_ROW_NUMBER":"117637","CASSETTE_NO":"58241213","SAMPLE_DT":"05/18/2016","QUARTZ_PCT":"04.8","QUARTZ_MICROGRAMS":"14","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-05-18"},{"SOURCE_ROW_NUMBER":"56071","CASSETTE_NO":"58241214","SAMPLE_DT":"05/18/2016","QUARTZ_PCT":"06.3","QUARTZ_MICROGRAMS":"11","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-05-18"},{"SOURCE_ROW_NUMBER":"36644","CASSETTE_NO":"58241200","SAMPLE_DT":"05/18/2016","QUARTZ_PCT":"03.6","QUARTZ_MICROGRAMS":"8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-05-18"},{"SOURCE_ROW_NUMBER":"108305","CASSETTE_NO":"58240312","SAMPLE_DT":"04/26/2016","QUARTZ_PCT":"04.7","QUARTZ_MICROGRAMS":"98","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2016-04-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":1223,"firstDate":"2009-05-26","lastDate":"2021-05-06","metrics":{"ss":334,"amountDue":342184,"contested":76,"amountPaid":232809.78,"recentRows":6,"section104d":3,"unterminated":15,"proposedPenalty":411094},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1144507","VIOLATION_NO":"9234337","VIOLATION_ISSUE_DT":"05/06/2021","PART_SECTION":"48.23(a)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/18/2023","CONTESTED_IND":"N","sourceDate":"2021-05-06"},{"SOURCE_ROW_NUMBER":"1144506","VIOLATION_NO":"9234336","VIOLATION_ISSUE_DT":"05/06/2021","PART_SECTION":"75.1711-2","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"11/07/2023","CONTESTED_IND":"N","sourceDate":"2021-05-06"},{"SOURCE_ROW_NUMBER":"1144505","VIOLATION_NO":"9234335","VIOLATION_ISSUE_DT":"05/06/2021","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","CONTESTED_IND":"N","sourceDate":"2021-05-06"},{"SOURCE_ROW_NUMBER":"1144504","VIOLATION_NO":"9234334","VIOLATION_ISSUE_DT":"04/30/2021","SIG_SUB":"N","PART_SECTION":"48.23(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"139","AMOUNT_DUE":"139","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-04-30"},{"SOURCE_ROW_NUMBER":"1144503","VIOLATION_NO":"9234333","VIOLATION_ISSUE_DT":"04/30/2021","SIG_SUB":"N","PART_SECTION":"75.1711-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"139","AMOUNT_DUE":"139","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-04-30"},{"SOURCE_ROW_NUMBER":"1144502","VIOLATION_NO":"9234332","VIOLATION_ISSUE_DT":"04/30/2021","SIG_SUB":"N","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"139","AMOUNT_DUE":"139","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2021-04-30"},{"SOURCE_ROW_NUMBER":"1144961","VIOLATION_NO":"8372410","VIOLATION_ISSUE_DT":"10/11/2017","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/12/2017","PROPOSED_PENALTY":"259","AMOUNT_DUE":"259","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"1144960","VIOLATION_NO":"8372409","VIOLATION_ISSUE_DT":"10/11/2017","SIG_SUB":"N","PART_SECTION":"75.333(b)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/12/2017","PROPOSED_PENALTY":"148","AMOUNT_DUE":"148","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"1144959","VIOLATION_NO":"8372408","VIOLATION_ISSUE_DT":"10/11/2017","SIG_SUB":"N","PART_SECTION":"75.606","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/12/2017","PROPOSED_PENALTY":"734","AMOUNT_DUE":"250","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-10-11"},{"SOURCE_ROW_NUMBER":"1144958","VIOLATION_NO":"8372407","VIOLATION_ISSUE_DT":"10/10/2017","SIG_SUB":"N","PART_SECTION":"75.1107-9(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/11/2017","PROPOSED_PENALTY":"148","AMOUNT_DUE":"148","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"1144957","VIOLATION_NO":"8372406","VIOLATION_ISSUE_DT":"10/10/2017","SIG_SUB":"N","PART_SECTION":"75.606","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/10/2017","PROPOSED_PENALTY":"148","AMOUNT_DUE":"148","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-10-10"},{"SOURCE_ROW_NUMBER":"1144956","VIOLATION_NO":"8372405","VIOLATION_ISSUE_DT":"10/10/2017","SIG_SUB":"N","PART_SECTION":"75.1505(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/10/2017","PROPOSED_PENALTY":"116","AMOUNT_DUE":"116","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2017-10-10"}]}],"safety":{"href":"/api/v1/mines/1519318/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519318/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Training plans; time of submission; where filed; information required; time for approval; method for disapproval; commencement of training; approval of instructors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.23","part":"48","subchapter":"H","subpart":"B","id":"48.23","citation":"30 CFR 48.23","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","heading":"Sealing of slope or drift openings.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711-2","part":"75","subchapter":"O","subpart":"R","id":"75.1711-2","citation":"30 CFR 75.1711-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.606","heading":"Protection of trailing cables.","id":"75.606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.606","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nTrailing cables shall be adequately protected to prevent damage by mobile equipment.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-9","heading":"Dry chemical devices; capacity; minimum requirements.","id":"75.1107-9","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-9","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Dry chemical fire extinguishing systems used on underground equipment shall be of the multipurpose powder-type and shall include the following:\n\n(1) The system including all hose and nozzles shall be protected against the entrance of moisture, dust, or dirt;\n\n(2) The system shall be guarded against damage during operation of the equipment protected;\n\n(3) Hose and pipe shall be as short as possible; the distance between the chemical container and furthest nozzle shall not exceed 50 feet;\n\n(4) Hose, piping, and fittings between the actuator and the chemical container shall have a bursting pressure of 500 pounds per square inch (gage) or higher; the hose, piping, and fittings between the chemical container and the nozzles shall have a bursting pressure of 300 pounds per square inch (gage) or higher and\n\n(5) The system shall discharge in 1 minute or less, for quantities less than 50 pounds (nominal) 1 and in less than 2 minutes for quantities more than 50 pounds;\n\n1 Many dry chemical systems were originally designed for sodium bicarbonate before all-purpose chemical (ammonium phosphate) was shown to be more effective. Sodium bicarbonate is denser than ammonium phosphate; hence, for example, a 50-pound system designed for the sodium bicarbonate will hold slightly more by weight than all-purpose dry chemical (ammonium phosphate) by weight. The word “nominal” is used in § 75.1107-9 to express the approximate weight in pounds of all-purpose dry chemical.\n\n(b) On unattended underground equipment, the number of pounds of dry chemical employed by the system shall be not less than 1 pound per square foot of top surface area of the equipment; however, the minimum amount in any system shall be 20 pounds (nominal). The discharge shall be directed into and on potentially hazardous locations of the equipment.\n\n(c) On attended underground equipment, the number of pounds (nominal) employed by the system shall equal 5 times the total number of hazardous locations; however, the minimum amount in any system shall not be less than the following, except that systems on haulage vehicles installed prior to the effective date of this section may contain 20 pounds (nominal).\n\nType of equipment Dry chemical pounds (nominal) (1) Cutting machines 40 (2) Continuous miners 40 (3) Haulage vehicles 30 (4) All other attended equipment 20\n\n(d) The amount of dry chemical discharged into the cable reel compartments of attended underground equipment shall be approximately 25 percent of the total amount required to be discharged by the system; however, the quantity discharged into cable reel compartments need not exceed 10 pounds.\n\n[37 FR 15302, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519318","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}