{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519314","name":"Mine No. 12","status":"Abandoned and Sealed","status_date":"2014-03-04","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Pikeville","operator_id":"P19831","operator_name":"McCoy Elkhorn Coal Corporation","controller_id":"C13562","controller_name":"James River Coal Company","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.470833,"longitude":-82.274722},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1294},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519314","name":"Mine No. 12"},"operator":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corporation"},"controller":{"type":"controller","id":"C13562","name":"James River Coal Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1519314","name":"Mine No. 12"},"validFrom":"1988-09-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|C13562|1988-09-28|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corp"},"object":{"type":"mine","id":"1519314","name":"Mine No. 12"},"validFrom":"2008-09-16","validTo":"2010-04-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|P19831|2008-09-16|2010-04-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corp"},"validFrom":"2008-09-16","validTo":"2010-04-25","current":false,"derived":true,"evidenceMineId":"1519314","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|P19831|2008-09-16|C13562|1988-09-28|90354"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0109428","name":"GR Mining Inc"},"object":{"type":"mine","id":"1519314","name":"Mine No. 12"},"validFrom":"2010-04-26","validTo":"2012-07-15","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|0109428|2010-04-26|2012-07-15"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13803","name":"Randy  Gilkerson et al"},"object":{"type":"mine","id":"1519314","name":"Mine No. 12"},"validFrom":"2010-04-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|C13803|2010-04-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13803","name":"Randy  Gilkerson et al"},"object":{"type":"operator","id":"0109428","name":"GR Mining Inc"},"validFrom":"2010-04-26","validTo":"2012-07-15","current":false,"derived":true,"evidenceMineId":"1519314","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|0109428|2010-04-26|C13803|2010-04-26|91210"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corporation"},"object":{"type":"mine","id":"1519314","name":"Mine No. 12"},"validFrom":"2012-07-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|P19831|2012-07-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19831","name":"McCoy Elkhorn Coal Corporation"},"validFrom":"2012-07-16","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519314","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519314|P19831|2012-07-16|C13562|1988-09-28|90355"}}],"coverage":{"historyRecords":3,"edgeCount":8,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":9,"firstDate":"2010-08-19","lastDate":"2013-12-09","metrics":{"daysLost":301,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"139184","DOCUMENT_NO":"220133530015","ACCIDENT_DT":"12/09/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Supply man, Nipper","NO_INJURIES":"1","DAYS_LOST":"69","NARRATIVE":"While lifting box of waterline out of mud hole he felt pain in lower back.","sourceDate":"2013-12-09"},{"SOURCE_ROW_NUMBER":"225194","DOCUMENT_NO":"220121630043","ACCIDENT_DT":"06/04/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"14","NARRATIVE":"Employee was loading supplies into scoop bucket and the bucket slipped onto his right foot.","sourceDate":"2012-06-04"},{"SOURCE_ROW_NUMBER":"35977","DOCUMENT_NO":"220120720013","ACCIDENT_DT":"03/08/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"1-intersection outby spad #286. Roof fall - #1 entry - return approximately 4800' from surface. Fall 25' long, 18' wide, 5'-6' high. Did not effect air way. Did not effect travelway.","sourceDate":"2012-03-08"},{"SOURCE_ROW_NUMBER":"208014","DOCUMENT_NO":"220120270011","ACCIDENT_DT":"01/17/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Had roof fall on intake break 66, in an intersection. Spad #250. 18'wide - 15'-18'high.","sourceDate":"2012-01-17"},{"SOURCE_ROW_NUMBER":"220951","DOCUMENT_NO":"220112270053","ACCIDENT_DT":"08/08/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"115","NARRATIVE":"Employee was seated waiting for miner operator to assist him during which time a rock fell from mine top striking lower right leg/ankle","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"31710","DOCUMENT_NO":"220111860045","ACCIDENT_DT":"06/27/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALLING/SLIDING/ROLLING MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"68","NARRATIVE":"Was checking on fellow employee changing flat tire on equipment. Crib block fell landing on foot.","sourceDate":"2011-06-27"},{"SOURCE_ROW_NUMBER":"14511","DOCUMENT_NO":"220111220044","ACCIDENT_DT":"04/28/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Rock fall in #5 entry 85' inby spad #245, approximately 25' Long & 8' High by 20' Wide.","sourceDate":"2011-04-28"},{"SOURCE_ROW_NUMBER":"74602","DOCUMENT_NO":"220103330008","ACCIDENT_DT":"11/18/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"25","NARRATIVE":"Employee stated that he lost his balance, slipped and fell landing on back.","sourceDate":"2010-11-18"},{"SOURCE_ROW_NUMBER":"251103","DOCUMENT_NO":"220102800036","ACCIDENT_DT":"08/19/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"10","NARRATIVE":"Employee stated that he had been installing mining timbers - when returning to equipment, he slipped on mat causing him to fall, striking rt. knee.","sourceDate":"2010-08-19"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-03-04","lastDate":"2014-03-04","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":334,"firstDate":"2008-12-10","lastDate":"2013-08-15","metrics":{"ss":138,"delinquent":334,"recentRows":0,"paidPenalty":84723.6,"proposedPenalty":174261,"currentAssessment":135733},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1942677","VIOLATION_NO":"8289447","ISSUE_DT":"08/15/2013","CFR_STANDARD_CD":"75.1714-8(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-15"},{"SOURCE_ROW_NUMBER":"1958741","VIOLATION_NO":"8273737","ISSUE_DT":"07/02/2013","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-07-02"},{"SOURCE_ROW_NUMBER":"1942595","VIOLATION_NO":"8289406","ISSUE_DT":"05/21/2013","CFR_STANDARD_CD":"75.1713-7(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-05-21"},{"SOURCE_ROW_NUMBER":"1942594","VIOLATION_NO":"8289401","ISSUE_DT":"04/25/2013","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-04-25"},{"SOURCE_ROW_NUMBER":"1943348","VIOLATION_NO":"8260092","ISSUE_DT":"03/13/2013","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"1943347","VIOLATION_NO":"8260085","ISSUE_DT":"02/20/2013","CFR_STANDARD_CD":"75.1100-2(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-02-20"},{"SOURCE_ROW_NUMBER":"1943350","VIOLATION_NO":"8267081","ISSUE_DT":"01/31/2013","CFR_STANDARD_CD":"75.337(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"1943349","VIOLATION_NO":"8267080","ISSUE_DT":"01/31/2013","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"1943327","VIOLATION_NO":"8260068","ISSUE_DT":"10/25/2012","CFR_STANDARD_CD":"47.51","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-25"},{"SOURCE_ROW_NUMBER":"1943326","VIOLATION_NO":"8260067","ISSUE_DT":"10/25/2012","CFR_STANDARD_CD":"75.1712-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-25"},{"SOURCE_ROW_NUMBER":"1943325","VIOLATION_NO":"8260064","ISSUE_DT":"10/17/2012","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"1958033","VIOLATION_NO":"8264029","ISSUE_DT":"05/17/2012","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-05-17"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":54,"firstDate":"2011-06-08","lastDate":"2013-07-30","metrics":{"appeals":0,"decisions":54,"recentRows":0,"decisionPenalty":62403,"originalPenalty":100931},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"88957","VIOLATION_NO":"8269158","DOCKET_NO":"KENT 2012-1314","DECISION_DT":"07/30/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1409.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2013-07-30"},{"SOURCE_ROW_NUMBER":"88956","VIOLATION_NO":"8269157","DOCKET_NO":"KENT 2012-1314","DECISION_DT":"07/30/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1409.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2013-07-30"},{"SOURCE_ROW_NUMBER":"88955","VIOLATION_NO":"8269156","DOCKET_NO":"KENT 2012-1314","DECISION_DT":"07/30/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","JUDGE_FIRST_NAME":"Michael","JUDGE_LAST_NAME":"Zielinski","sourceDate":"2013-07-30"},{"SOURCE_ROW_NUMBER":"325889","VIOLATION_NO":"8268998","DOCKET_NO":"KENT 2012-1106","DECISION_DT":"06/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7578.00","DECISION_PENALTY_AMT":"4431.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-06-26"},{"SOURCE_ROW_NUMBER":"325888","VIOLATION_NO":"8268996","DOCKET_NO":"KENT 2012-1106","DECISION_DT":"06/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"2282.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-06-26"},{"SOURCE_ROW_NUMBER":"325175","VIOLATION_NO":"8268999","DOCKET_NO":"KENT 2012-1106","DECISION_DT":"06/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1412.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-06-26"},{"SOURCE_ROW_NUMBER":"325096","VIOLATION_NO":"8268997","DOCKET_NO":"KENT 2012-1106","DECISION_DT":"06/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"2282.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-06-26"},{"SOURCE_ROW_NUMBER":"324980","VIOLATION_NO":"8268995","DOCKET_NO":"KENT 2012-1106","DECISION_DT":"06/26/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"285.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-06-26"},{"SOURCE_ROW_NUMBER":"329068","VIOLATION_NO":"8269134","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1944.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-19"},{"SOURCE_ROW_NUMBER":"328365","VIOLATION_NO":"8269359","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"1304.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-19"},{"SOURCE_ROW_NUMBER":"328364","VIOLATION_NO":"8269169","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-19"},{"SOURCE_ROW_NUMBER":"328363","VIOLATION_NO":"8269164","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-19"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":195,"firstDate":"2009-01-28","lastDate":"2012-06-05","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":22,"validSamples":173,"maxConcentration":44.124,"concentrationTotal":161.228},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"853094","CASS_NUM":"51152590","SMP_TAKEN_DT":"6/5/2012","CONC":".139","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"246030","CASS_NUM":"51153033","SMP_TAKEN_DT":"5/31/2012","CONC":".517","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-31"},{"SOURCE_ROW_NUMBER":"427698","CASS_NUM":"51152679","SMP_TAKEN_DT":"5/30/2012","CONC":".481","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-30"},{"SOURCE_ROW_NUMBER":"1402369","CASS_NUM":"51153133","SMP_TAKEN_DT":"5/29/2012","CONC":".494","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-29"},{"SOURCE_ROW_NUMBER":"304725","CASS_NUM":"51153068","SMP_TAKEN_DT":"5/28/2012","CONC":".153","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-28"},{"SOURCE_ROW_NUMBER":"519051","CASS_NUM":"51153129","SMP_TAKEN_DT":"5/11/2012","CONC":"2.41","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTAMINATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-11"},{"SOURCE_ROW_NUMBER":"1470978","CASS_NUM":"51153032","SMP_TAKEN_DT":"5/10/2012","CONC":"1.154","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-10"},{"SOURCE_ROW_NUMBER":"1144997","CASS_NUM":"51152724","SMP_TAKEN_DT":"5/9/2012","CONC":".803","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"Miner is not active with QnC","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-09"},{"SOURCE_ROW_NUMBER":"752861","CASS_NUM":"51153131","SMP_TAKEN_DT":"5/8/2012","CONC":"2.052","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTAMINATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-08"},{"SOURCE_ROW_NUMBER":"60840","CASS_NUM":"51111041","SMP_TAKEN_DT":"5/7/2012","CONC":"2.038","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"CONTAMINATED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-07"},{"SOURCE_ROW_NUMBER":"1427263","CASS_NUM":"57981040","SMP_TAKEN_DT":"5/2/2012","CONC":".089","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-02"},{"SOURCE_ROW_NUMBER":"505284","CASS_NUM":"57980968","SMP_TAKEN_DT":"5/2/2012","CONC":".097","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-02"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2010-09-23","lastDate":"2012-04-27","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":54,"firstDate":"2009-03-16","lastDate":"2012-05-09","metrics":{"decisions":54,"ssChanged":6,"recentRows":0,"decisionPenalty":62403,"proposedPenalty":100931},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"425787","CITATION_NO":"8269384","CITATION_ISSUE_DT":"05/09/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.606","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"117.00","sourceDate":"2012-05-09"},{"SOURCE_ROW_NUMBER":"83530","CITATION_NO":"8269383","CITATION_ISSUE_DT":"05/09/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.203(e)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"117.00","sourceDate":"2012-05-09"},{"SOURCE_ROW_NUMBER":"199643","CITATION_NO":"8269359","CITATION_ISSUE_DT":"05/07/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"1304.00","sourceDate":"2012-05-07"},{"SOURCE_ROW_NUMBER":"82735","CITATION_NO":"8269361","CITATION_ISSUE_DT":"05/07/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"1304.00","sourceDate":"2012-05-07"},{"SOURCE_ROW_NUMBER":"30198","CITATION_NO":"8269360","CITATION_ISSUE_DT":"05/07/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"687.00","sourceDate":"2012-05-07"},{"SOURCE_ROW_NUMBER":"254837","CITATION_NO":"8269356","CITATION_ISSUE_DT":"05/03/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"687.00","sourceDate":"2012-05-03"},{"SOURCE_ROW_NUMBER":"312754","CITATION_NO":"8269156","CITATION_ISSUE_DT":"05/02/2012","DOCKET_NO":"KENT 2012-1314","DECISION_DT":"07/30/2013","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2012-05-02"},{"SOURCE_ROW_NUMBER":"254836","CITATION_NO":"8269157","CITATION_ISSUE_DT":"05/02/2012","DOCKET_NO":"KENT 2012-1314","DECISION_DT":"07/30/2013","CFR_STANDARD_CODE":"77.1104","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1409.00","sourceDate":"2012-05-02"},{"SOURCE_ROW_NUMBER":"199554","CITATION_NO":"8269158","CITATION_ISSUE_DT":"05/02/2012","DOCKET_NO":"KENT 2012-1314","DECISION_DT":"07/30/2013","CFR_STANDARD_CODE":"77.1104","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1409.00","sourceDate":"2012-05-02"},{"SOURCE_ROW_NUMBER":"425024","CITATION_NO":"8269198","CITATION_ISSUE_DT":"04/24/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2012-04-24"},{"SOURCE_ROW_NUMBER":"85410","CITATION_NO":"8269186","CITATION_ISSUE_DT":"04/17/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.904","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2012-04-17"},{"SOURCE_ROW_NUMBER":"30735","CITATION_NO":"8269184","CITATION_ISSUE_DT":"04/17/2012","DOCKET_NO":"KENT 2012-1312","DECISION_DT":"04/19/2013","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"392.00","DECISION_PENALTY_AMT":"392.00","sourceDate":"2012-04-17"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":129,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":26,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2008-09-16","lastDate":"2012-07-16","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":2},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":51,"firstDate":"2008-09-16","lastDate":"2014-03-04","metrics":{"inspectors":85,"recentRows":0,"onSiteHours":1543.5,"inspectionHours":2299.5,"inspectionSamples":246},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"511097","EVENT_NO":"6381910","INSPECTION_BEGIN_DT":"03/04/2014","INSPECTION_END_DT":"03/04/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"519620","EVENT_NO":"6381908","INSPECTION_BEGIN_DT":"10/25/2013","INSPECTION_END_DT":"12/23/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2013-10-25"},{"SOURCE_ROW_NUMBER":"250889","EVENT_NO":"6381769","INSPECTION_BEGIN_DT":"07/09/2013","INSPECTION_END_DT":"08/22/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"27","SUM_TOTAL_ON_SITE_HOURS":"18.25","sourceDate":"2013-07-09"},{"SOURCE_ROW_NUMBER":"589692","EVENT_NO":"6393856","INSPECTION_BEGIN_DT":"07/02/2013","INSPECTION_END_DT":"07/02/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2013-07-02"},{"SOURCE_ROW_NUMBER":"94249","EVENT_NO":"6381764","INSPECTION_BEGIN_DT":"04/23/2013","INSPECTION_END_DT":"06/04/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"57.5","SUM_TOTAL_ON_SITE_HOURS":"33.75","sourceDate":"2013-04-23"},{"SOURCE_ROW_NUMBER":"9413","EVENT_NO":"6381859","INSPECTION_BEGIN_DT":"01/08/2013","INSPECTION_END_DT":"03/28/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"45","SUM_TOTAL_ON_SITE_HOURS":"28.25","sourceDate":"2013-01-08"},{"SOURCE_ROW_NUMBER":"356824","EVENT_NO":"6381853","INSPECTION_BEGIN_DT":"10/10/2012","INSPECTION_END_DT":"12/21/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"72.5","SUM_TOTAL_ON_SITE_HOURS":"37","sourceDate":"2012-10-10"},{"SOURCE_ROW_NUMBER":"513008","EVENT_NO":"6381563","INSPECTION_BEGIN_DT":"07/16/2012","INSPECTION_END_DT":"08/14/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"26","SUM_TOTAL_ON_SITE_HOURS":"17.5","sourceDate":"2012-07-16"},{"SOURCE_ROW_NUMBER":"1153150","EVENT_NO":"6392181","INSPECTION_BEGIN_DT":"06/21/2012","INSPECTION_END_DT":"06/21/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"874673","EVENT_NO":"6392952","INSPECTION_BEGIN_DT":"05/17/2012","INSPECTION_END_DT":"05/18/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2012-05-17"},{"SOURCE_ROW_NUMBER":"918219","EVENT_NO":"6381371","INSPECTION_BEGIN_DT":"05/16/2012","INSPECTION_END_DT":"05/21/2012","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2012-05-16"},{"SOURCE_ROW_NUMBER":"531839","EVENT_NO":"6381554","INSPECTION_BEGIN_DT":"04/16/2012","INSPECTION_END_DT":"04/16/2012","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-04-16"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":33,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013-Q4":{"hours":10,"employees":1,"production":0},"2013-Q3":{"hours":0,"employees":0,"production":0},"2013-Q2":{"hours":0,"employees":0,"production":0},"2013-Q1":{"hours":0,"employees":0,"production":0},"2012-Q4":{"hours":0,"employees":0,"production":0},"2012-Q2":{"hours":14316,"employees":23,"production":22530},"2012-Q1":{"hours":15145,"employees":25,"production":22630},"2011-Q4":{"hours":15351,"employees":24,"production":23774},"2011-Q3":{"hours":14153,"employees":26,"production":24920},"2011-Q2":{"hours":15350,"employees":26,"production":29244},"2011-Q1":{"hours":13324,"employees":22,"production":27117},"2010-Q4":{"hours":11521,"employees":21,"production":21824}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":9,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":4378,"employees":10,"production":5466},"2009":{"hours":56646,"employees":25,"production":69085},"2010":{"hours":32033,"employees":17,"production":45663},"2011":{"hours":58178,"employees":25,"production":105055},"2012":{"hours":29461,"employees":24,"production":45160},"2013":{"hours":10,"employees":1,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":28,"firstDate":"2009-03-03","lastDate":"2011-11-09","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":2060,"pelDoseTotal":1539},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"100130","EVENT_NO":"6381180","SURVEY_DATE":"11/09/2011","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2011-11-09"},{"SOURCE_ROW_NUMBER":"100137","EVENT_NO":"6381180","SURVEY_DATE":"10/13/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"56","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"100136","EVENT_NO":"6381180","SURVEY_DATE":"10/13/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"88","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"100135","EVENT_NO":"6381180","SURVEY_DATE":"10/13/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"30","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"100134","EVENT_NO":"6381180","SURVEY_DATE":"10/13/2011","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"119","ACT_DOSE_85":"60","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"100133","EVENT_NO":"6381180","SURVEY_DATE":"10/13/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"42","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"100132","EVENT_NO":"6381180","SURVEY_DATE":"10/13/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"38","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"100131","EVENT_NO":"6381180","SURVEY_DATE":"10/13/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"64","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2011-10-13"},{"SOURCE_ROW_NUMBER":"100122","EVENT_NO":"6380887","SURVEY_DATE":"01/27/2011","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"31","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2011-01-27"},{"SOURCE_ROW_NUMBER":"100121","EVENT_NO":"6380882","SURVEY_DATE":"10/14/2010","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"08","MANUFACTURER_CD":"120","ACT_DOSE_85":"69","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2010-10-14"},{"SOURCE_ROW_NUMBER":"100120","EVENT_NO":"6380882","SURVEY_DATE":"10/14/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"65","SURVEY_TYPE":"I","sourceDate":"2010-10-14"},{"SOURCE_ROW_NUMBER":"100119","EVENT_NO":"6380882","SURVEY_DATE":"10/14/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"83","PEL_DOSE_90":"63","SURVEY_TYPE":"I","sourceDate":"2010-10-14"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":12,"firstDate":"2009-02-25","lastDate":"2012-05-11","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":22.3,"validSamples":11,"quartzPctTotal":94.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"19126","CASSETTE_NO":"51153025","SAMPLE_DT":"05/11/2012","QUARTZ_PCT":"08.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-05-11"},{"SOURCE_ROW_NUMBER":"36070","CASSETTE_NO":"57949990","SAMPLE_DT":"04/11/2012","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-11"},{"SOURCE_ROW_NUMBER":"162862","CASSETTE_NO":"57950230","SAMPLE_DT":"03/06/2012","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-03-06"},{"SOURCE_ROW_NUMBER":"136317","CASSETTE_NO":"51145432","SAMPLE_DT":"10/14/2011","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-10-14"},{"SOURCE_ROW_NUMBER":"134863","CASSETTE_NO":"51110959","SAMPLE_DT":"09/30/2011","QUARTZ_PCT":"07.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-30"},{"SOURCE_ROW_NUMBER":"131313","CASSETTE_NO":"57858487","SAMPLE_DT":"09/01/2011","QUARTZ_PCT":"22.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-01"},{"SOURCE_ROW_NUMBER":"49981","CASSETTE_NO":"57858439","SAMPLE_DT":"04/20/2011","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-04-20"},{"SOURCE_ROW_NUMBER":"144931","CASSETTE_NO":"51079663","SAMPLE_DT":"10/28/2010","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2010-10-28"},{"SOURCE_ROW_NUMBER":"111657","CASSETTE_NO":"51079640","SAMPLE_DT":"09/20/2010","QUARTZ_PCT":"15.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-09-20"},{"SOURCE_ROW_NUMBER":"106428","CASSETTE_NO":"57803456","SAMPLE_DT":"07/14/2009","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-07-14"},{"SOURCE_ROW_NUMBER":"156359","CASSETTE_NO":"57763750","SAMPLE_DT":"04/02/2009","QUARTZ_PCT":"07.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-04-02"},{"SOURCE_ROW_NUMBER":"16519","CASSETTE_NO":"57764071","SAMPLE_DT":"02/25/2009","QUARTZ_PCT":"05.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-02-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":349,"firstDate":"2008-12-10","lastDate":"2013-08-15","metrics":{"ss":138,"amountDue":135733,"contested":12,"amountPaid":84723.6,"recentRows":0,"section104d":6,"unterminated":1,"proposedPenalty":174261},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1143701","VIOLATION_NO":"8289447","VIOLATION_ISSUE_DT":"08/15/2013","SIG_SUB":"N","PART_SECTION":"75.1714-8(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/22/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-15"},{"SOURCE_ROW_NUMBER":"1143692","VIOLATION_NO":"8273737","VIOLATION_ISSUE_DT":"07/02/2013","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/02/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-07-02"},{"SOURCE_ROW_NUMBER":"1143645","VIOLATION_NO":"8289406","VIOLATION_ISSUE_DT":"05/21/2013","SIG_SUB":"N","PART_SECTION":"75.1713-7(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-05-21"},{"SOURCE_ROW_NUMBER":"1143644","VIOLATION_NO":"8289401","VIOLATION_ISSUE_DT":"04/25/2013","SIG_SUB":"N","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"05/09/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-04-25"},{"SOURCE_ROW_NUMBER":"1143504","VIOLATION_NO":"8260092","VIOLATION_ISSUE_DT":"03/13/2013","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/13/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-03-13"},{"SOURCE_ROW_NUMBER":"1143503","VIOLATION_NO":"8260085","VIOLATION_ISSUE_DT":"02/20/2013","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/20/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-02-20"},{"SOURCE_ROW_NUMBER":"1143506","VIOLATION_NO":"8267081","VIOLATION_ISSUE_DT":"01/31/2013","SIG_SUB":"N","PART_SECTION":"75.337(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"01/31/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"1143505","VIOLATION_NO":"8267080","VIOLATION_ISSUE_DT":"01/31/2013","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/31/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-31"},{"SOURCE_ROW_NUMBER":"1143799","VIOLATION_NO":"8260068","VIOLATION_ISSUE_DT":"10/25/2012","SIG_SUB":"N","PART_SECTION":"47.51","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/25/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-25"},{"SOURCE_ROW_NUMBER":"1143798","VIOLATION_NO":"8260067","VIOLATION_ISSUE_DT":"10/25/2012","SIG_SUB":"N","PART_SECTION":"75.1712-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"3","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/17/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-10-25"},{"SOURCE_ROW_NUMBER":"1143797","VIOLATION_NO":"8260064","VIOLATION_ISSUE_DT":"10/17/2012","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/19/2012","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2012-10-17"},{"SOURCE_ROW_NUMBER":"1143655","VIOLATION_NO":"8264029","VIOLATION_ISSUE_DT":"05/17/2012","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/17/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-05-17"}]}],"safety":{"href":"/api/v1/mines/1519314/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519314/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Reporting SCSR inventory and malfunctions; retention of SCSRs.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-8","part":"75","subchapter":"O","subpart":"R","id":"75.1714-8","citation":"30 CFR 75.1714-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","heading":"First-aid equipment; location; minimum requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1713-7","part":"75","subchapter":"O","subpart":"R","id":"75.1713-7","citation":"30 CFR 75.1713-7","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.337","heading":"Construction and repair of seals.","id":"75.337","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.337","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) The mine operator shall maintain and repair seals to protect miners from hazards of sealed areas.\n\n(b) Prior to sealing, the mine operator shall—\n\n(1) Remove insulated cables, batteries, and other potential electric ignition sources from the area to be sealed when constructing seals, unless it is not safe to do so. If ignition sources cannot safely be removed, seals must be constructed to at least 120 psi;\n\n(2) Remove metallic objects through or across seals; and\n\n(3) Breach or remove all stoppings in the first crosscut inby the seals immediately prior to sealing the area.\n\n(c) A certified person designated by the mine operator shall directly supervise seal construction and repair and—\n\n(1) Examine each seal site immediately prior to construction or repair to ensure that the site is in accordance with the approved ventilation plan;\n\n(2) Examine each seal under construction or repair during each shift to ensure that the seal is being constructed or repaired in accordance with the approved ventilation plan;\n\n(3) Examine each seal upon completion of construction or repair to ensure that construction or repair is in accordance with the approved ventilation plan;\n\n(4) Certify by initials, date, and time that the examinations were made; and\n\n(5) Make a record of the examination at the completion of any shift during which an examination was conducted. The record shall include each deficiency and the corrective action taken. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be kept at the mine for one year.\n\n(d) Upon completion of construction of each seal a senior mine management official, such as a mine manager or superintendent, shall certify that the construction, installation, and materials used were in accordance with the approved ventilation plan. The mine operator shall retain the certification for as long as the seal is needed to serve the purpose for which it was built.\n\n(e) The mine operator shall—\n\n(1) Notify the District Manager between two and fourteen days prior to commencement of seal construction;\n\n(2) Notify the District Manager, in writing, within five days of completion of a set of seals and provide a copy of the certification required in paragraph (d) of this section; and\n\n(3) Submit a copy of quality control results to the District Manager for seal material properties specified by § 75.335 within 30 days of completion of quality control tests.\n\n(f) Welding, cutting, and soldering. Welding, cutting, and soldering with an arc or flame are prohibited within 150 feet of a seal. An operator may request a different location in the ventilation plan to be approved by the District Manager. The operator's request must address methods the mine operator will use to continuously monitor atmospheric conditions in the sealed area during welding or burning; the airflow conditions in and around the work area; the rock dust and water application methods; the availability of fire extinguishers on hand; the procedures to maintain safe conditions, and other relevant factors.\n\n(g) Sampling pipes. (1) For seals constructed after April 18, 2008, one non-metallic sampling pipe shall be installed in each seal that shall extend into the center of the first connecting crosscut inby the seal. If an open crosscut does not exist, the sampling pipe shall extend one-half of the distance of the open entry inby the seal.\n\n(2) Each sampling pipe shall be equipped with a shut-off valve and appropriate fittings for taking gas samples.\n\n(3) The sampling pipes shall be labeled to indicate the location of the sampling point when more than one sampling pipe is installed through a seal.\n\n(4) If a new seal is constructed to replace or reinforce an existing seal with a sampling pipe, the sampling pipe in the existing seal shall extend through the new seal. An additional sampling pipe shall be installed through each new seal to sample the area between seals, as specified in the approved ventilation plan.\n\n(h) Water drainage system. For each set of seals constructed after April 18, 2008, the seal at the lowest elevation shall have a corrosion-resistant, non-metallic water drainage system. Seals shall not impound water or slurry. Water or slurry shall not accumulate within the sealed area to any depth that can adversely affect a seal.\n\n[73 FR 21207, Apr. 18, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","heading":"Requirement for an MSDS.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-47/subpart-F/section-47.51","part":"47","subchapter":"H","subpart":"F","id":"47.51","citation":"30 CFR 47.51","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 47—HAZARD COMMUNICATION (HazCom)","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Availability of surface bathing facilities; change rooms; and sanitary facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1712-1","part":"75","subchapter":"O","subpart":"R","id":"75.1712-1","citation":"30 CFR 75.1712-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519314","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}