{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519270","name":"Love Branch South","status":"Abandoned and Sealed","status_date":"2012-12-10","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Stone","operator_id":"P22248","operator_name":"Road Fork Development Company Inc.","controller_id":"0127321","controller_name":"Alpha Metallurgical Resources Inc","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.538611,"longitude":-82.249166},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2793},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519270","name":"Love Branch South"},"operator":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc."},"controller":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1519270","name":"Love Branch South"},"validFrom":"1993-01-01","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|C02508|1993-01-01|2011-05-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc."},"object":{"type":"mine","id":"1519270","name":"Love Branch South"},"validFrom":"2008-07-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|P22248|2008-07-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc."},"validFrom":"2008-07-23","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1519270","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|P22248|2008-07-23|C02508|1993-01-01|59310"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1519270","name":"Love Branch South"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc."},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"1519270","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|P22248|2008-07-23|0041211|2011-06-01|1901"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"1519270","name":"Love Branch South"},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|0127923|2016-07-26|2018-11-08"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc."},"validFrom":"2016-07-26","validTo":"2018-11-08","current":false,"derived":true,"evidenceMineId":"1519270","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|P22248|2008-07-23|0127923|2016-07-26|25119"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"mine","id":"1519270","name":"Love Branch South"},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|0127321|2018-11-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127321","name":"Alpha Metallurgical Resources Inc"},"object":{"type":"operator","id":"P22248","name":"Road Fork Development Company Inc."},"validFrom":"2018-11-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519270","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519270|P22248|2008-07-23|0127321|2018-11-09|24754"}}],"coverage":{"historyRecords":4,"edgeCount":9,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":17,"firstDate":"2009-01-21","lastDate":"2012-07-27","metrics":{"daysLost":415,"injuries":16,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"233843","DOCUMENT_NO":"220122130024","ACCIDENT_DT":"07/27/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Utility man, Errand boy, Service truck operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While cutting conveyor belt employee lost his balance and almost fell causing the knife to push into his leg.","sourceDate":"2012-07-27"},{"SOURCE_ROW_NUMBER":"173580","DOCUMENT_NO":"220121790030","ACCIDENT_DT":"06/01/2012","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"44","NARRATIVE":"While cutting a rope hanger with a utility knife he cut his hand, requiring stitches.","sourceDate":"2012-06-01"},{"SOURCE_ROW_NUMBER":"91766","DOCUMENT_NO":"220121030042","ACCIDENT_DT":"04/11/2012","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Supply man, Supply worker, Nipper","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was putting hydraulic oil in the scoop. He repositioned the can to better align it over the hole when his hand slipped off the can striking a hydraulic saw causing a laceration that required stitches.","sourceDate":"2012-04-11"},{"SOURCE_ROW_NUMBER":"212329","DOCUMENT_NO":"220121010012","ACCIDENT_DT":"04/02/2012","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A non-injury roof fall occurred in the Northwest Mains at break 33 of old #6 belt, 1 x-cut inby spad 2044 in the #1 entry. The fall was approximately 25'L X 19'W X 7'H in an intersection.","sourceDate":"2012-04-02"},{"SOURCE_ROW_NUMBER":"87585","DOCUMENT_NO":"220112690046","ACCIDENT_DT":"09/21/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STRIKING OR BUMPING","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was walking towards the rear of the roof bolter and did not see a roof strap that was damaged.  Employee struck the roof strap with his shoulder and neck resulting in a laceration that required stitches to close the wound.","sourceDate":"2011-09-21"},{"SOURCE_ROW_NUMBER":"225188","DOCUMENT_NO":"220111640002","ACCIDENT_DT":"06/07/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was walking across the section toward the roof bolter, he bent down to go through a line curtain and after he stepped through the curtain he twisted his ankle.","sourceDate":"2011-06-07"},{"SOURCE_ROW_NUMBER":"57378","DOCUMENT_NO":"220111460016","ACCIDENT_DT":"05/23/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"7","NARRATIVE":"Employee was hanging line curtain and as he turned around to leave the area, he tripped over a rock and fell landing on his knee.","sourceDate":"2011-05-23"},{"SOURCE_ROW_NUMBER":"259756","DOCUMENT_NO":"220110400011","ACCIDENT_DT":"02/03/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was installing a man door in a previously built stopping. He placed his left hand on the bottom row of block and a block fell from the top row of block causing a laceration to his index finger.","sourceDate":"2011-02-03"},{"SOURCE_ROW_NUMBER":"147842","DOCUMENT_NO":"220110120005","ACCIDENT_DT":"01/08/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"139","NARRATIVE":"Employee was walking down hill going to the mantrip when he slipped and fell, causing a strain to his lower back. Hill was snow covered from heavy snow fall.","sourceDate":"2011-01-08"},{"SOURCE_ROW_NUMBER":"152114","DOCUMENT_NO":"220110120028","ACCIDENT_DT":"10/15/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was making a belt splice. After end of splice was complete, the two ends would not align, so employee was going to cut off a clip on belt when the knife slipped causing a laceration to his left palm.","sourceDate":"2010-10-15"},{"SOURCE_ROW_NUMBER":"156427","DOCUMENT_NO":"220102850060","ACCIDENT_DT":"10/09/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was cutting a bolt out of the section head drive motor. He laid the cutting torch across his legs (he was sitting cross-legged). He reached up with his left hand and torch fell off his leg and landed on his hand. He was taken to ER and treated for minor burns and was released to return to work on 10/11/10.","sourceDate":"2010-10-09"},{"SOURCE_ROW_NUMBER":"10161","DOCUMENT_NO":"220102850059","ACCIDENT_DT":"10/09/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was in the process of switching seats after dumping his loaded shuttle car when he stepped on a rock causing his knee to twist. He finished his shift and transported himself to hospital where x-rays were negative. He was given a brace and was released with no restrictions to return to work on 10/10/10.","sourceDate":"2010-10-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-12-10","lastDate":"2012-12-10","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":656,"firstDate":"2008-08-13","lastDate":"2012-12-10","metrics":{"ss":243,"delinquent":656,"recentRows":0,"paidPenalty":426055.12,"proposedPenalty":639160,"currentAssessment":552788},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1058827","VIOLATION_NO":"8275535","ISSUE_DT":"12/10/2012","CFR_STANDARD_CD":"48.31","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"705.00","CURRENT_ASSESSMENT_AMT":"705.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-12-10"},{"SOURCE_ROW_NUMBER":"1958081","VIOLATION_NO":"8273990","ISSUE_DT":"09/13/2012","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-13"},{"SOURCE_ROW_NUMBER":"1958080","VIOLATION_NO":"8273989","ISSUE_DT":"09/11/2012","CFR_STANDARD_CD":"75.1909(c)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"1958079","VIOLATION_NO":"8273988","ISSUE_DT":"09/11/2012","CFR_STANDARD_CD":"75.1106-2(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"1958078","VIOLATION_NO":"8273987","ISSUE_DT":"09/11/2012","CFR_STANDARD_CD":"75.523-3(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"1958077","VIOLATION_NO":"8273986","ISSUE_DT":"09/10/2012","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"540.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"1958076","VIOLATION_NO":"8273985","ISSUE_DT":"09/05/2012","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"540.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1958075","VIOLATION_NO":"8273984","ISSUE_DT":"09/05/2012","CFR_STANDARD_CD":"75.320(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"127.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1958074","VIOLATION_NO":"8273983","ISSUE_DT":"09/05/2012","CFR_STANDARD_CD":"75.360(g)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1057397","VIOLATION_NO":"8270214","ISSUE_DT":"06/13/2012","CFR_STANDARD_CD":"75.1103-11","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-13"},{"SOURCE_ROW_NUMBER":"1057396","VIOLATION_NO":"8270213","ISSUE_DT":"06/13/2012","CFR_STANDARD_CD":"75.1914(h)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-13"},{"SOURCE_ROW_NUMBER":"1057395","VIOLATION_NO":"8270212","ISSUE_DT":"06/07/2012","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2012-06-07"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":120,"firstDate":"2011-01-28","lastDate":"2014-02-28","metrics":{"appeals":0,"decisions":120,"recentRows":0,"decisionPenalty":193987,"originalPenalty":267955},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"330823","VIOLATION_NO":"8269289","DOCKET_NO":"KENT 2012-1481","DECISION_DT":"02/28/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"972.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2014-02-28"},{"SOURCE_ROW_NUMBER":"309962","VIOLATION_NO":"8259070","DOCKET_NO":"KENT 2011-1595","DECISION_DT":"07/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"745.00","DECISION_PENALTY_AMT":"489.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2013-07-15"},{"SOURCE_ROW_NUMBER":"309075","VIOLATION_NO":"8259343","DOCKET_NO":"KENT 2011-1595","DECISION_DT":"07/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"690.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2013-07-15"},{"SOURCE_ROW_NUMBER":"309034","VIOLATION_NO":"8238801","DOCKET_NO":"KENT 2011-1595","DECISION_DT":"07/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2013-07-15"},{"SOURCE_ROW_NUMBER":"309033","VIOLATION_NO":"8238797","DOCKET_NO":"KENT 2011-1595","DECISION_DT":"07/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"176.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2013-07-15"},{"SOURCE_ROW_NUMBER":"308004","VIOLATION_NO":"8262491","DOCKET_NO":"KENT 2011-1430","DECISION_DT":"07/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"520.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2013-07-15"},{"SOURCE_ROW_NUMBER":"307270","VIOLATION_NO":"8262494","DOCKET_NO":"KENT 2011-1430","DECISION_DT":"07/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"250.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2013-07-15"},{"SOURCE_ROW_NUMBER":"75918","VIOLATION_NO":"8262492","DOCKET_NO":"KENT 2011-1430","DECISION_DT":"07/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1637.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2013-07-15"},{"SOURCE_ROW_NUMBER":"319555","VIOLATION_NO":"8265084","DOCKET_NO":"KENT 2012-651","DECISION_DT":"04/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"5747.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-15"},{"SOURCE_ROW_NUMBER":"319278","VIOLATION_NO":"8248517","DOCKET_NO":"KENT 2012-651","DECISION_DT":"04/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"54000.00","DECISION_PENALTY_AMT":"21458.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-15"},{"SOURCE_ROW_NUMBER":"85790","VIOLATION_NO":"8269042","DOCKET_NO":"KENT 2012-901","DECISION_DT":"04/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"7578.00","DECISION_PENALTY_AMT":"3500.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-15"},{"SOURCE_ROW_NUMBER":"85789","VIOLATION_NO":"8269041","DOCKET_NO":"KENT 2012-901","DECISION_DT":"04/15/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"3500.00","JUDGE_FIRST_NAME":"Thomas","JUDGE_LAST_NAME":"McCarthy","sourceDate":"2013-04-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":504,"firstDate":"2009-01-05","lastDate":"2012-05-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":100,"validSamples":404,"maxConcentration":12.829,"concentrationTotal":360.714},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"992437","CASS_NUM":"51159374","SMP_TAKEN_DT":"5/25/2012","CONC":".711","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-25"},{"SOURCE_ROW_NUMBER":"1488459","CASS_NUM":"51159140","SMP_TAKEN_DT":"5/24/2012","CONC":"2.406","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-24"},{"SOURCE_ROW_NUMBER":"1120472","CASS_NUM":"51159564","SMP_TAKEN_DT":"5/24/2012","CONC":".163","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-24"},{"SOURCE_ROW_NUMBER":"1512174","CASS_NUM":"51159700","SMP_TAKEN_DT":"5/23/2012","CONC":".133","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"OPERATOR VOID; PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-23"},{"SOURCE_ROW_NUMBER":"1512173","CASS_NUM":"51159127","SMP_TAKEN_DT":"5/23/2012","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-23"},{"SOURCE_ROW_NUMBER":"1192362","CASS_NUM":"51159119","SMP_TAKEN_DT":"5/22/2012","CONC":"1.901","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-22"},{"SOURCE_ROW_NUMBER":"360743","CASS_NUM":"51159708","SMP_TAKEN_DT":"5/22/2012","CONC":"1.049","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-22"},{"SOURCE_ROW_NUMBER":"1602352","CASS_NUM":"51159133","SMP_TAKEN_DT":"5/21/2012","CONC":".861","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-21"},{"SOURCE_ROW_NUMBER":"9380","CASS_NUM":"51176250","SMP_TAKEN_DT":"5/17/2012","CONC":".245","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-17"},{"SOURCE_ROW_NUMBER":"1562211","CASS_NUM":"51176241","SMP_TAKEN_DT":"5/16/2012","CONC":".868","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-16"},{"SOURCE_ROW_NUMBER":"330745","CASS_NUM":"51176240","SMP_TAKEN_DT":"5/16/2012","CONC":"1.152","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-16"},{"SOURCE_ROW_NUMBER":"304724","CASS_NUM":"51176227","SMP_TAKEN_DT":"5/15/2012","CONC":".774","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-05-15"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":13,"firstDate":"2009-03-31","lastDate":"2012-05-04","metrics":{"linkedIssuances":13},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":122,"firstDate":"2009-02-11","lastDate":"2012-06-05","metrics":{"decisions":122,"ssChanged":71,"recentRows":0,"decisionPenalty":193987,"proposedPenalty":273655},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"83091","CITATION_NO":"8269289","CITATION_ISSUE_DT":"06/05/2012","DOCKET_NO":"KENT 2012-1481","DECISION_DT":"02/28/2014","CFR_STANDARD_CODE":"77.1605(d)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"972.00","sourceDate":"2012-06-05"},{"SOURCE_ROW_NUMBER":"197891","CITATION_NO":"8269041","CITATION_ISSUE_DT":"02/15/2012","DOCKET_NO":"KENT 2012-901","DECISION_DT":"04/15/2013","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"3500.00","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"28741","CITATION_NO":"8269042","CITATION_ISSUE_DT":"02/15/2012","DOCKET_NO":"KENT 2012-901","DECISION_DT":"04/15/2013","CFR_STANDARD_CODE":"77.1104","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"7578.00","DECISION_PENALTY_AMT":"3500.00","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"252942","CITATION_NO":"8265226","CITATION_ISSUE_DT":"01/11/2012","DOCKET_NO":"KENT 2012-717","DECISION_DT":"03/22/2013","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1795.00","DECISION_PENALTY_AMT":"1276.00","sourceDate":"2012-01-11"},{"SOURCE_ROW_NUMBER":"196295","CITATION_NO":"8265084","CITATION_ISSUE_DT":"11/28/2011","DOCKET_NO":"KENT 2012-651","DECISION_DT":"04/15/2013","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"8209.00","DECISION_PENALTY_AMT":"5747.00","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"83202","CITATION_NO":"8251981","CITATION_ISSUE_DT":"11/28/2011","DOCKET_NO":"KENT 2012-651","DECISION_DT":"04/15/2013","CFR_STANDARD_CODE":"70.101","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3493.00","DECISION_PENALTY_AMT":"2795.00","sourceDate":"2011-11-28"},{"SOURCE_ROW_NUMBER":"365214","CITATION_NO":"8248517","CITATION_ISSUE_DT":"11/09/2011","DOCKET_NO":"KENT 2012-651","DECISION_DT":"04/15/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"54000.00","DECISION_PENALTY_AMT":"21458.00","sourceDate":"2011-11-09"},{"SOURCE_ROW_NUMBER":"27314","CITATION_NO":"8259378","CITATION_ISSUE_DT":"08/22/2011","DOCKET_NO":"KENT 2012-46","DECISION_DT":"10/24/2012","CFR_STANDARD_CODE":"75.380(d)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"930.00","sourceDate":"2011-08-22"},{"SOURCE_ROW_NUMBER":"423791","CITATION_NO":"8259371","CITATION_ISSUE_DT":"08/18/2011","DOCKET_NO":"KENT 2012-46","DECISION_DT":"10/24/2012","CFR_STANDARD_CODE":"75.1101-10","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1000.00","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"365013","CITATION_NO":"8259372","CITATION_ISSUE_DT":"08/18/2011","DOCKET_NO":"KENT 2012-46","DECISION_DT":"10/24/2012","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2901.00","DECISION_PENALTY_AMT":"2400.00","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"27738","CITATION_NO":"8259370","CITATION_ISSUE_DT":"08/18/2011","DOCKET_NO":"KENT 2012-46","DECISION_DT":"10/24/2012","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2282.00","DECISION_PENALTY_AMT":"1600.00","sourceDate":"2011-08-18"},{"SOURCE_ROW_NUMBER":"196519","CITATION_NO":"8259367","CITATION_ISSUE_DT":"08/15/2011","DOCKET_NO":"KENT 2012-46","DECISION_DT":"10/24/2012","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"1800.00","sourceDate":"2011-08-15"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":404,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":84,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":7,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2008-07-23","lastDate":"2008-07-23","metrics":{"recentRows":0,"currentOperatorTenures":4,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":60,"firstDate":"2008-08-11","lastDate":"2012-12-10","metrics":{"inspectors":151,"recentRows":0,"onSiteHours":2766.75,"inspectionHours":4295.25,"inspectionSamples":364},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1160055","EVENT_NO":"4199501","INSPECTION_BEGIN_DT":"12/10/2012","INSPECTION_END_DT":"12/12/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2012-12-10"},{"SOURCE_ROW_NUMBER":"637898","EVENT_NO":"6393061","INSPECTION_BEGIN_DT":"09/04/2012","INSPECTION_END_DT":"09/27/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"70","SUM_TOTAL_ON_SITE_HOURS":"45","sourceDate":"2012-09-04"},{"SOURCE_ROW_NUMBER":"350929","EVENT_NO":"6392706","INSPECTION_BEGIN_DT":"07/02/2012","INSPECTION_END_DT":"07/17/2012","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2012-07-02"},{"SOURCE_ROW_NUMBER":"1101821","EVENT_NO":"6392456","INSPECTION_BEGIN_DT":"04/26/2012","INSPECTION_END_DT":"04/26/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2012-04-26"},{"SOURCE_ROW_NUMBER":"363171","EVENT_NO":"4198591","INSPECTION_BEGIN_DT":"04/04/2012","INSPECTION_END_DT":"06/26/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"12","SUM_TOTAL_INSP_HOURS":"353.5","SUM_TOTAL_ON_SITE_HOURS":"232.75","sourceDate":"2012-04-04"},{"SOURCE_ROW_NUMBER":"150409","EVENT_NO":"6381367","INSPECTION_BEGIN_DT":"04/02/2012","INSPECTION_END_DT":"08/30/2012","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2012-04-02"},{"SOURCE_ROW_NUMBER":"235070","EVENT_NO":"6381366","INSPECTION_BEGIN_DT":"03/30/2012","INSPECTION_END_DT":"04/09/2012","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12.75","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2012-03-30"},{"SOURCE_ROW_NUMBER":"416780","EVENT_NO":"6392126","INSPECTION_BEGIN_DT":"03/21/2012","INSPECTION_END_DT":"03/21/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2012-03-21"},{"SOURCE_ROW_NUMBER":"862374","EVENT_NO":"6381509","INSPECTION_BEGIN_DT":"02/15/2012","INSPECTION_END_DT":"02/22/2012","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"14.25","sourceDate":"2012-02-15"},{"SOURCE_ROW_NUMBER":"634995","EVENT_NO":"6381506","INSPECTION_BEGIN_DT":"01/03/2012","INSPECTION_END_DT":"03/22/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"7","SUM_TOTAL_INSP_HOURS":"300","SUM_TOTAL_ON_SITE_HOURS":"202","sourceDate":"2012-01-03"},{"SOURCE_ROW_NUMBER":"1062610","EVENT_NO":"6391948","INSPECTION_BEGIN_DT":"12/09/2011","INSPECTION_END_DT":"12/09/2011","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2011-12-09"},{"SOURCE_ROW_NUMBER":"679745","EVENT_NO":"4200761","INSPECTION_BEGIN_DT":"11/08/2011","INSPECTION_END_DT":"01/17/2012","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"35","SUM_TOTAL_ON_SITE_HOURS":"15.75","sourceDate":"2011-11-08"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":44,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q4":{"hours":184,"employees":1,"production":0},"2012-Q3":{"hours":2296,"employees":18,"production":0},"2012-Q2":{"hours":19507,"employees":52,"production":47094},"2012-Q1":{"hours":30528,"employees":54,"production":88019},"2011-Q4":{"hours":30385,"employees":46,"production":79449},"2011-Q3":{"hours":30651,"employees":55,"production":64914},"2011-Q2":{"hours":32317,"employees":53,"production":102862},"2011-Q1":{"hours":33003,"employees":53,"production":96445},"2010-Q4":{"hours":23087,"employees":43,"production":101488},"2010-Q3":{"hours":24652,"employees":42,"production":95523},"2010-Q2":{"hours":25774,"employees":43,"production":110806},"2010-Q1":{"hours":22791,"employees":43,"production":96800}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":4884,"employees":11,"production":11253},"2009":{"hours":95019,"employees":42,"production":393787},"2010":{"hours":96304,"employees":43,"production":404617},"2011":{"hours":126356,"employees":53,"production":343670},"2012":{"hours":52515,"employees":34,"production":135113}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":51,"firstDate":"2009-02-18","lastDate":"2011-12-13","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":2448,"pelDoseTotal":1767},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"99346","EVENT_NO":"6381097","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"32","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"99343","EVENT_NO":"6381097","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"ELECTRICIAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"27","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"99342","EVENT_NO":"6381097","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"55","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"99341","EVENT_NO":"6381097","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"41","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"99340","EVENT_NO":"6381097","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"82","PEL_DOSE_90":"68","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"99339","EVENT_NO":"6381097","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"47","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"99338","EVENT_NO":"6381097","SURVEY_DATE":"12/13/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"84","PEL_DOSE_90":"67","SURVEY_TYPE":"I","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"99345","EVENT_NO":"6381097","SURVEY_DATE":"12/05/2011","OCCUPATION_CD_DESC":"DISPATCHER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"19","PEL_DOSE_90":"3","SURVEY_TYPE":"I","sourceDate":"2011-12-05"},{"SOURCE_ROW_NUMBER":"99344","EVENT_NO":"6381097","SURVEY_DATE":"12/05/2011","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"120","ACT_DOSE_85":"26","PEL_DOSE_90":"7","SURVEY_TYPE":"I","sourceDate":"2011-12-05"},{"SOURCE_ROW_NUMBER":"99337","EVENT_NO":"6381097","SURVEY_DATE":"11/01/2011","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"45","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2011-11-01"},{"SOURCE_ROW_NUMBER":"99336","EVENT_NO":"6381097","SURVEY_DATE":"11/01/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"51","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2011-11-01"},{"SOURCE_ROW_NUMBER":"99335","EVENT_NO":"6381097","SURVEY_DATE":"11/01/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"31","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2011-11-01"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":22,"firstDate":"2009-02-18","lastDate":"2012-04-12","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":22.4,"validSamples":19,"quartzPctTotal":126.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"92084","CASSETTE_NO":"57978413","SAMPLE_DT":"04/12/2012","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-04-12"},{"SOURCE_ROW_NUMBER":"59345","CASSETTE_NO":"57950119","SAMPLE_DT":"01/13/2012","QUARTZ_PCT":"06.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2012-01-13"},{"SOURCE_ROW_NUMBER":"31144","CASSETTE_NO":"57889366","SAMPLE_DT":"12/13/2011","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-12-13"},{"SOURCE_ROW_NUMBER":"41201","CASSETTE_NO":"51128809","SAMPLE_DT":"08/29/2011","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"OVERSIZE PARTICLES","sourceDate":"2011-08-29"},{"SOURCE_ROW_NUMBER":"92980","CASSETTE_NO":"57858326","SAMPLE_DT":"08/09/2011","QUARTZ_PCT":"11.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-08-09"},{"SOURCE_ROW_NUMBER":"97931","CASSETTE_NO":"57858208","SAMPLE_DT":"04/18/2011","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-04-18"},{"SOURCE_ROW_NUMBER":"91157","CASSETTE_NO":"57858505","SAMPLE_DT":"04/18/2011","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-04-18"},{"SOURCE_ROW_NUMBER":"109307","CASSETTE_NO":"51094647","SAMPLE_DT":"02/10/2011","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-10"},{"SOURCE_ROW_NUMBER":"133936","CASSETTE_NO":"57826824","SAMPLE_DT":"01/19/2011","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-19"},{"SOURCE_ROW_NUMBER":"106563","CASSETTE_NO":"57826825","SAMPLE_DT":"11/09/2010","QUARTZ_PCT":"00.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-11-09"},{"SOURCE_ROW_NUMBER":"85664","CASSETTE_NO":"57826867","SAMPLE_DT":"11/09/2010","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-11-09"},{"SOURCE_ROW_NUMBER":"20642","CASSETTE_NO":"57826866","SAMPLE_DT":"11/09/2010","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-11-09"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":678,"firstDate":"2008-08-13","lastDate":"2012-12-10","metrics":{"ss":243,"amountDue":552788,"contested":88,"amountPaid":426055.12,"recentRows":0,"section104d":9,"unterminated":4,"proposedPenalty":639160},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1138000","VIOLATION_NO":"8275535","VIOLATION_ISSUE_DT":"12/10/2012","SIG_SUB":"Y","PART_SECTION":"48.31","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"12/10/2012","PROPOSED_PENALTY":"705","AMOUNT_DUE":"705","AMOUNT_PAID":"705","CONTESTED_IND":"N","sourceDate":"2012-12-10"},{"SOURCE_ROW_NUMBER":"1137917","VIOLATION_NO":"8273990","VIOLATION_ISSUE_DT":"09/13/2012","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/27/2012","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"285","CONTESTED_IND":"N","sourceDate":"2012-09-13"},{"SOURCE_ROW_NUMBER":"1137916","VIOLATION_NO":"8273989","VIOLATION_ISSUE_DT":"09/11/2012","SIG_SUB":"Y","PART_SECTION":"75.1909(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/13/2012","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"1412","CONTESTED_IND":"N","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"1137915","VIOLATION_NO":"8273988","VIOLATION_ISSUE_DT":"09/11/2012","SIG_SUB":"Y","PART_SECTION":"75.1106-2(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/11/2012","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"1412","CONTESTED_IND":"N","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"1137914","VIOLATION_NO":"8273987","VIOLATION_ISSUE_DT":"09/11/2012","SIG_SUB":"N","PART_SECTION":"75.523-3(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/11/2012","PROPOSED_PENALTY":"127","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"N","sourceDate":"2012-09-11"},{"SOURCE_ROW_NUMBER":"1137913","VIOLATION_NO":"8273986","VIOLATION_ISSUE_DT":"09/10/2012","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/11/2012","PROPOSED_PENALTY":"540","AMOUNT_DUE":"540","AMOUNT_PAID":"540","CONTESTED_IND":"N","sourceDate":"2012-09-10"},{"SOURCE_ROW_NUMBER":"1137912","VIOLATION_NO":"8273985","VIOLATION_ISSUE_DT":"09/05/2012","SIG_SUB":"N","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/05/2012","PROPOSED_PENALTY":"540","AMOUNT_DUE":"540","AMOUNT_PAID":"540","CONTESTED_IND":"N","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1137911","VIOLATION_NO":"8273984","VIOLATION_ISSUE_DT":"09/05/2012","SIG_SUB":"N","PART_SECTION":"75.320(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/11/2012","PROPOSED_PENALTY":"127","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"N","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1137910","VIOLATION_NO":"8273983","VIOLATION_ISSUE_DT":"09/05/2012","SIG_SUB":"N","PART_SECTION":"75.360(g)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"09/05/2012","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"634","CONTESTED_IND":"N","sourceDate":"2012-09-05"},{"SOURCE_ROW_NUMBER":"1137591","VIOLATION_NO":"8270214","VIOLATION_ISSUE_DT":"06/13/2012","SIG_SUB":"N","PART_SECTION":"75.1103-11","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2012","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2012-06-13"},{"SOURCE_ROW_NUMBER":"1137590","VIOLATION_NO":"8270213","VIOLATION_ISSUE_DT":"06/13/2012","SIG_SUB":"N","PART_SECTION":"75.1914(h)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/21/2012","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2012-06-13"},{"SOURCE_ROW_NUMBER":"1137589","VIOLATION_NO":"8270212","VIOLATION_ISSUE_DT":"06/07/2012","SIG_SUB":"N","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/21/2012","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2012-06-07"}]}],"safety":{"href":"/api/v1/mines/1519270/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519270/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.31","part":"48","subchapter":"H","subpart":"B","id":"48.31","citation":"30 CFR 48.31","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1909","heading":"Nonpermissible diesel-powered equipment; design and performance requirements.","id":"75.1909","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1909","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:\n\n(1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;\n\n(2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;\n\n(3) A fuel system specifically designed for diesel fuel meeting the following requirements:\n\n(i) A fuel tank and fuel lines that do not leak;\n\n(ii) A fuel tank that is substantially constructed and protected against damage by collision;\n\n(iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;\n\n(iv) A self-closing filler cap on the fuel tank;\n\n(v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;\n\n(vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;\n\n(vii) Fuel line piping must be clamped;\n\n(viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;\n\n(ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;\n\n(x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and\n\n(xi) A water separator and fuel filter(s) must be provided.\n\n(4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;\n\n(5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;\n\n(6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;\n\n(7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;\n\n(8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;\n\n(9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and\n\n(10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.\n\n(b) Self-propelled nonpermissible diesel-powered equipment must have the following features in addition to those in paragraph (a):\n\n(1) A means to ensure that no stored hydraulic energy that will cause machine articulation is available after the engine is shut down;\n\n(2) A neutral start feature which ensures that engine cranking torque will not be transmitted through the powertrain and cause machine movement on vehicles utilizing fluid power transmissions;\n\n(3) For machines with steering wheels, brake pedals, and accelerator pedals, controls which are of automobile orientation;\n\n(4) An audible warning device conveniently located near the equipment operator;\n\n(5) Lights provided and maintained on both ends of the equipment. Equipment normally operated in both directions must be equipped with headlights for both directions;\n\n(6) Service brakes that act on each wheel of the vehicle and that are designed such that failure of any single component, except the brake actuation pedal or other similar actuation device, must not result in a complete loss of service braking capability;\n\n(7) Service brakes that safely bring the fully loaded vehicle to a complete stop on the maximum grade on which it is operated; and\n\n(8) No device that traps a column of fluid to hold the brake in the applied position shall be installed in any brake system, unless the trapped column of fluid is released when the equipment operator is no longer in contact with the brake activation device.\n\n(c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:\n\n(1) Engages automatically within 5 seconds of the shutdown of the engine;\n\n(2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;\n\n(4) Releases only by a manual control that does not operate any other equipment function;\n\n(5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and\n\n(6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.\n\n(e) The supplemental and park brake systems required by paragraphs (c) and (d) must be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n(f) Self-propelled personnel-elevating work platforms must be provided with a means to ensure that the parking braking system is released before the equipment can be trammed, and must be designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(g) Any nonpermissible equipment that discharges its exhaust directly into a return air course must be provided with a power package approved under subpart F of part 7 of this title.\n\n(h) Self-propelled nonpermissible heavy-duty diesel-powered equipment meeting the requirements of § 75.1908(a) must be provided with an automatic fire suppression system meeting the requirements of § 75.1911.\n\n(i) Self-propelled nonpermissible light-duty diesel-powered equipment meeting the requirements of § 75.1908(b) must be provided with an automatic or manual fire suppression system meeting the requirements of § 75.1911.\n\n(j) Nonpermissible equipment that is not self-propelled must have the following features in addition to those listed in paragraph (a):\n\n(1) A means to prevent inadvertent movement of the equipment when parked;\n\n(2) Safety chains or other suitable secondary connections on equipment that is being towed; and\n\n(3) An automatic fire suppression system meeting the requirements of § 75.1911.\n\n[61 FR 55527, Oct. 25, 1996; 62 FR 34641, June 27, 1997]","occurrenceCount":1},{"chapter":"I","heading":"Transportation of liquefied and nonliquefied compressed gas cylinders; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-2","part":"75","subchapter":"O","subpart":"L","id":"75.1106-2","citation":"30 CFR 75.1106-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","heading":"Air quality detectors and measurement devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.320","part":"75","subchapter":"O","subpart":"D","id":"75.320","citation":"30 CFR 75.320","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","heading":"Tests of fire hydrants and fire hose; record of tests.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-11","part":"75","subchapter":"O","subpart":"L","id":"75.1103-11","citation":"30 CFR 75.1103-11","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1914","heading":"Maintenance of diesel-powered equipment.","id":"75.1914","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1914","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Diesel-powered equipment shall be maintained in approved and safe condition or removed from service.\n\n(b) Maintenance and repairs of approved features and those features required by §§ 75.1909 and 75.1910 on diesel-powered equipment shall be made only by a person qualified under § 75.1915.\n\n(c) The water scrubber system on diesel-powered equipment shall be drained and flushed, by a person who is trained to perform this task, at least once on each shift in which the equipment is operated.\n\n(d) The intake air filter on diesel-powered equipment shall be replaced or serviced, by a person who is trained to perform this task, when the intake air pressure drop device so indicates or when the engine manufacturer's maximum allowable air pressure drop level is exceeded.\n\n(e) Mobile diesel-powered equipment that is to be used during a shift shall be visually examined by the equipment operator before being placed in operation. Equipment defects affecting safety shall be reported promptly to the mine operator.\n\n(f) All diesel-powered equipment shall be examined and tested weekly by a person qualified under § 75.1915.\n\n(1) Examinations and tests shall be conducted in accordance with approved checklists and manufacturers' maintenance manuals.\n\n(2) Persons performing weekly examinations and tests of diesel-powered equipment under this paragraph shall make a record when the equipment is not in approved or safe condition. The record shall include the equipment that is not in approved or safe condition, the defect found, and the corrective action taken.\n\n(g) Undiluted exhaust emissions of diesel engines in diesel-powered equipment approved under part 36 and heavy-duty nonpermissible diesel-powered equipment as defined in § 75.1908(a) in use in underground coal mines shall be tested and evaluated weekly by a person who is trained to perform this task. The mine operator shall develop and implement written standard operating procedures for such testing and evaluation that specify the following:\n\n(1) The method of achieving a repeatable loaded engine operating condition for each type of equipment;\n\n(2) Sampling and analytical methods (including calibration of instrumentation) that are capable of accurately detecting carbon monoxide in the expected concentrations;\n\n(3) The method of evaluation and interpretation of the results;\n\n(4) The concentration or changes in concentration of carbon monoxide that will indicate a change in engine performance. Carbon monoxide concentration shall not exceed 2500 parts per million; and\n\n(5) The maintenance of records necessary to track engine performance.\n\n(h) Recordkeeping. Records required by paragraphs (f)(2) and (g)(5) shall be—\n\n(1) Recorded in a secure book that is not susceptible to alteration, or recorded electronically in a computer system that is secure and not susceptible to alteration; and\n\n(2) Retained at a surface location at the mine for at least 1 year and made available for inspection by an authorized representative of the Secretary and by miners' representatives.\n\n(i) Diesel-powered equipment must be maintained in accordance with this part as of November 25, 1997.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519270","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}