{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519246","name":"#1","status":"Abandoned and Sealed","status_date":"2010-04-13","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Coleman","operator_id":"0100805","operator_name":"TLT Resources Corporation","controller_id":"0085093","controller_name":"Gerald K  Thacker","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.477222,"longitude":-82.172777},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":605},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519246","name":"#1"},"operator":{"type":"operator","id":"0100805","name":"TLT Resources Corporation"},"controller":{"type":"controller","id":"0085093","name":"Gerald K  Thacker"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0091045","name":"KiMara Coal Co LLC"},"object":{"type":"mine","id":"1519246","name":"#1"},"validFrom":"2008-06-16","validTo":"2009-05-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519246|0091045|2008-06-16|2009-05-17"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0046909","name":"Scarlett  Biliter"},"object":{"type":"mine","id":"1519246","name":"#1"},"validFrom":"2008-06-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519246|0046909|2008-06-16|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0046909","name":"Scarlett  Biliter"},"object":{"type":"operator","id":"0091045","name":"KiMara Coal Co LLC"},"validFrom":"2008-06-16","validTo":"2009-05-17","current":false,"derived":true,"evidenceMineId":"1519246","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519246|0091045|2008-06-16|0046909|2008-06-16|5733"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0100805","name":"TLT Resources Corporation"},"object":{"type":"mine","id":"1519246","name":"#1"},"validFrom":"2009-05-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519246|0100805|2009-05-18|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0085093","name":"Gerald K  Thacker"},"object":{"type":"mine","id":"1519246","name":"#1"},"validFrom":"2009-05-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519246|0085093|2009-05-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0085093","name":"Gerald K  Thacker"},"object":{"type":"operator","id":"0100805","name":"TLT Resources Corporation"},"validFrom":"2009-05-18","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519246","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519246|0100805|2009-05-18|0085093|2009-05-18|13431"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":2,"firstDate":"2008-09-16","lastDate":"2009-03-10","metrics":{"daysLost":0,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"35967","DOCUMENT_NO":"220090760017","ACCIDENT_DT":"03/10/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Roof Bolting and employee states the ATRS fell striking employee.  Alleged Accident investigated by mine foreman and no sign of inoperable or malfunction ATRS found.","sourceDate":"2009-03-10"},{"SOURCE_ROW_NUMBER":"186520","DOCUMENT_NO":"220082770055","ACCIDENT_DT":"09/16/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in pulling or pushing objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating cutter. He had cut the reel valve off by mistake, and was trying to pull cable by hand.","sourceDate":"2008-09-16"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2010-04-13","lastDate":"2010-04-13","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":204,"firstDate":"2008-08-19","lastDate":"2010-01-14","metrics":{"ss":90,"delinquent":204,"recentRows":0,"paidPenalty":16887.61,"proposedPenalty":61237,"currentAssessment":60833},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1938946","VIOLATION_NO":"7446537","ISSUE_DT":"01/14/2010","CFR_STANDARD_CD":"70.207(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2010-01-14"},{"SOURCE_ROW_NUMBER":"973969","VIOLATION_NO":"7446529","ISSUE_DT":"12/11/2009","CFR_STANDARD_CD":"72.630(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"973983","VIOLATION_NO":"7446754","ISSUE_DT":"12/03/2009","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-03"},{"SOURCE_ROW_NUMBER":"973982","VIOLATION_NO":"7446753","ISSUE_DT":"12/03/2009","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-03"},{"SOURCE_ROW_NUMBER":"973981","VIOLATION_NO":"7446752","ISSUE_DT":"12/02/2009","CFR_STANDARD_CD":"75.601-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-02"},{"SOURCE_ROW_NUMBER":"973980","VIOLATION_NO":"7446751","ISSUE_DT":"12/02/2009","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-02"},{"SOURCE_ROW_NUMBER":"973968","VIOLATION_NO":"7446526","ISSUE_DT":"12/02/2009","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-02"},{"SOURCE_ROW_NUMBER":"973979","VIOLATION_NO":"7446750","ISSUE_DT":"12/01/2009","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"973978","VIOLATION_NO":"7446749","ISSUE_DT":"12/01/2009","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"973977","VIOLATION_NO":"7446748","ISSUE_DT":"12/01/2009","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"973976","VIOLATION_NO":"7446747","ISSUE_DT":"11/30/2009","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-11-30"},{"SOURCE_ROW_NUMBER":"973975","VIOLATION_NO":"7446746","ISSUE_DT":"11/25/2009","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-11-25"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":3,"firstDate":"2011-03-18","lastDate":"2011-03-18","metrics":{"appeals":0,"decisions":3,"recentRows":0,"decisionPenalty":6589,"originalPenalty":6993},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"261702","VIOLATION_NO":"7446237","DOCKET_NO":"KENT 2010-245","DECISION_DT":"03/18/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-03-18"},{"SOURCE_ROW_NUMBER":"260707","VIOLATION_NO":"7446238","DOCKET_NO":"KENT 2010-246","DECISION_DT":"03/18/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"900.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-03-18"},{"SOURCE_ROW_NUMBER":"260706","VIOLATION_NO":"7446112","DOCKET_NO":"KENT 2010-245","DECISION_DT":"03/18/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"3689.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-03-18"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":84,"firstDate":"2008-09-11","lastDate":"2009-12-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":24,"validSamples":60,"maxConcentration":13.92,"concentrationTotal":46.321},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"878927","CASS_NUM":"57764209","SMP_TAKEN_DT":"12/14/2009","CONC":".514","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-12-14"},{"SOURCE_ROW_NUMBER":"1628919","CASS_NUM":"57764259","SMP_TAKEN_DT":"12/11/2009","CONC":".702","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"1339445","CASS_NUM":"57764273","SMP_TAKEN_DT":"12/11/2009","CONC":".214","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"1209695","CASS_NUM":"57764234","SMP_TAKEN_DT":"12/11/2009","CONC":".31","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"1152604","CASS_NUM":"57764222","SMP_TAKEN_DT":"12/11/2009","CONC":".291","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"873641","CASS_NUM":"57764252","SMP_TAKEN_DT":"12/11/2009","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"6764","CASS_NUM":"57764250","SMP_TAKEN_DT":"12/11/2009","CONC":".05","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"183889","CASS_NUM":"51041154","SMP_TAKEN_DT":"11/13/2009","CONC":".211","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-11-13"},{"SOURCE_ROW_NUMBER":"44270","CASS_NUM":"51041149","SMP_TAKEN_DT":"11/11/2009","CONC":"2.426","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-11-11"},{"SOURCE_ROW_NUMBER":"1563099","CASS_NUM":"51041167","SMP_TAKEN_DT":"11/10/2009","CONC":"2.136","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-11-10"},{"SOURCE_ROW_NUMBER":"369209","CASS_NUM":"51041150","SMP_TAKEN_DT":"11/9/2009","CONC":"2.061","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-11-09"},{"SOURCE_ROW_NUMBER":"430897","CASS_NUM":"51041151","SMP_TAKEN_DT":"11/7/2009","CONC":".537","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-11-07"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":3,"firstDate":"2009-09-26","lastDate":"2009-10-05","metrics":{"decisions":3,"ssChanged":0,"recentRows":0,"decisionPenalty":6589,"proposedPenalty":6993},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"77572","CITATION_NO":"7446237","CITATION_ISSUE_DT":"10/05/2009","DOCKET_NO":"KENT 2010-245","DECISION_DT":"03/18/2011","CFR_STANDARD_CODE":"75.388","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2009-10-05"},{"SOURCE_ROW_NUMBER":"74268","CITATION_NO":"7446238","CITATION_ISSUE_DT":"10/05/2009","DOCKET_NO":"KENT 2010-246","DECISION_DT":"03/18/2011","CFR_STANDARD_CODE":"75.360","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1304.00","DECISION_PENALTY_AMT":"900.00","sourceDate":"2009-10-05"},{"SOURCE_ROW_NUMBER":"296764","CITATION_NO":"7446112","CITATION_ISSUE_DT":"09/26/2009","DOCKET_NO":"KENT 2010-245","DECISION_DT":"03/18/2011","CFR_STANDARD_CODE":"75.360","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3689.00","DECISION_PENALTY_AMT":"3689.00","sourceDate":"2009-09-26"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":32,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2008-06-16","lastDate":"2009-05-18","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":21,"firstDate":"2008-06-30","lastDate":"2010-04-02","metrics":{"inspectors":47,"recentRows":0,"onSiteHours":745,"inspectionHours":1058.75,"inspectionSamples":110},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"143611","EVENT_NO":"6380921","INSPECTION_BEGIN_DT":"04/02/2010","INSPECTION_END_DT":"04/13/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2010-04-02"},{"SOURCE_ROW_NUMBER":"1136844","EVENT_NO":"6381001","INSPECTION_BEGIN_DT":"03/01/2010","INSPECTION_END_DT":"03/01/2010","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.25","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2010-03-01"},{"SOURCE_ROW_NUMBER":"186489","EVENT_NO":"6380904","INSPECTION_BEGIN_DT":"01/04/2010","INSPECTION_END_DT":"02/09/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"24.75","SUM_TOTAL_ON_SITE_HOURS":"16.75","sourceDate":"2010-01-04"},{"SOURCE_ROW_NUMBER":"212117","EVENT_NO":"4173843","INSPECTION_BEGIN_DT":"10/19/2009","INSPECTION_END_DT":"10/19/2009","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"11.25","sourceDate":"2009-10-19"},{"SOURCE_ROW_NUMBER":"1018728","EVENT_NO":"4173840","INSPECTION_BEGIN_DT":"10/02/2009","INSPECTION_END_DT":"12/28/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"225.75","SUM_TOTAL_ON_SITE_HOURS":"179","sourceDate":"2009-10-02"},{"SOURCE_ROW_NUMBER":"60498","EVENT_NO":"4197282","INSPECTION_BEGIN_DT":"09/30/2009","INSPECTION_END_DT":"10/02/2009","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2009-09-30"},{"SOURCE_ROW_NUMBER":"489800","EVENT_NO":"4173880","INSPECTION_BEGIN_DT":"09/25/2009","INSPECTION_END_DT":"09/28/2009","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"22.5","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2009-09-25"},{"SOURCE_ROW_NUMBER":"204670","EVENT_NO":"4197262","INSPECTION_BEGIN_DT":"08/19/2009","INSPECTION_END_DT":"08/24/2009","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2009-08-19"},{"SOURCE_ROW_NUMBER":"862408","EVENT_NO":"4173878","INSPECTION_BEGIN_DT":"07/22/2009","INSPECTION_END_DT":"07/24/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.75","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"690153","EVENT_NO":"4173733","INSPECTION_BEGIN_DT":"07/01/2009","INSPECTION_END_DT":"09/29/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"160","SUM_TOTAL_ON_SITE_HOURS":"119","sourceDate":"2009-07-01"},{"SOURCE_ROW_NUMBER":"468178","EVENT_NO":"4173729","INSPECTION_BEGIN_DT":"04/14/2009","INSPECTION_END_DT":"05/18/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"23.75","SUM_TOTAL_ON_SITE_HOURS":"13","sourceDate":"2009-04-14"},{"SOURCE_ROW_NUMBER":"111071","EVENT_NO":"6366068","INSPECTION_BEGIN_DT":"04/06/2009","INSPECTION_END_DT":"04/07/2009","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2009-04-06"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009-Q3":{"hours":6344,"employees":13,"production":12153},"2009-Q2":{"hours":4059,"employees":17,"production":2069},"2009-Q1":{"hours":3447,"employees":9,"production":5367},"2008-Q4":{"hours":4478,"employees":19,"production":9322},"2008-Q3":{"hours":2162,"employees":12,"production":5834},"2008-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008":{"hours":6640,"employees":16,"production":15156},"2009":{"hours":13850,"employees":14,"production":19589}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":17,"firstDate":"2008-09-11","lastDate":"2009-11-20","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":730,"pelDoseTotal":491},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"98676","EVENT_NO":"4173840","SURVEY_DATE":"11/20/2009","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"5","PEL_DOSE_90":"1","SURVEY_TYPE":"I","sourceDate":"2009-11-20"},{"SOURCE_ROW_NUMBER":"98675","EVENT_NO":"4173840","SURVEY_DATE":"11/13/2009","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"19","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2009-11-13"},{"SOURCE_ROW_NUMBER":"98674","EVENT_NO":"4173840","SURVEY_DATE":"11/13/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"29","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2009-11-13"},{"SOURCE_ROW_NUMBER":"98673","EVENT_NO":"4173840","SURVEY_DATE":"11/13/2009","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"100","ACT_DOSE_85":"40","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2009-11-13"},{"SOURCE_ROW_NUMBER":"98672","EVENT_NO":"4173840","SURVEY_DATE":"11/13/2009","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"43","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2009-11-13"},{"SOURCE_ROW_NUMBER":"98671","EVENT_NO":"4173840","SURVEY_DATE":"11/13/2009","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2009-11-13"},{"SOURCE_ROW_NUMBER":"98665","EVENT_NO":"4173733","SURVEY_DATE":"08/13/2009","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"27","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2009-08-13"},{"SOURCE_ROW_NUMBER":"98681","EVENT_NO":"6366008","SURVEY_DATE":"03/24/2009","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"23","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2009-03-24"},{"SOURCE_ROW_NUMBER":"98680","EVENT_NO":"6366008","SURVEY_DATE":"03/24/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"73","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2009-03-24"},{"SOURCE_ROW_NUMBER":"98679","EVENT_NO":"6366008","SURVEY_DATE":"03/24/2009","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"101","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2009-03-24"},{"SOURCE_ROW_NUMBER":"98678","EVENT_NO":"6366008","SURVEY_DATE":"03/24/2009","OCCUPATION_CD_DESC":"ROCKMAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"17","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2009-03-24"},{"SOURCE_ROW_NUMBER":"98677","EVENT_NO":"6366008","SURVEY_DATE":"03/24/2009","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"87","PEL_DOSE_90":"84","SURVEY_TYPE":"I","sourceDate":"2009-03-24"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":212,"firstDate":"2008-08-19","lastDate":"2010-01-14","metrics":{"ss":90,"amountDue":60833,"contested":3,"amountPaid":16887.61,"recentRows":0,"section104d":2,"unterminated":1,"proposedPenalty":61237},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1133482","VIOLATION_NO":"7446537","VIOLATION_ISSUE_DT":"01/14/2010","SIG_SUB":"N","PART_SECTION":"70.207(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"01/14/2010","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2010-01-14"},{"SOURCE_ROW_NUMBER":"1133672","VIOLATION_NO":"7446529","VIOLATION_ISSUE_DT":"12/11/2009","SIG_SUB":"Y","PART_SECTION":"72.630(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/14/2009","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"150","CONTESTED_IND":"N","sourceDate":"2009-12-11"},{"SOURCE_ROW_NUMBER":"1133686","VIOLATION_NO":"7446754","VIOLATION_ISSUE_DT":"12/03/2009","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-03"},{"SOURCE_ROW_NUMBER":"1133685","VIOLATION_NO":"7446753","VIOLATION_ISSUE_DT":"12/03/2009","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/04/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-03"},{"SOURCE_ROW_NUMBER":"1133684","VIOLATION_NO":"7446752","VIOLATION_ISSUE_DT":"12/02/2009","SIG_SUB":"N","PART_SECTION":"75.601-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/03/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-02"},{"SOURCE_ROW_NUMBER":"1133683","VIOLATION_NO":"7446751","VIOLATION_ISSUE_DT":"12/02/2009","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/03/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-02"},{"SOURCE_ROW_NUMBER":"1133671","VIOLATION_NO":"7446526","VIOLATION_ISSUE_DT":"12/02/2009","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/02/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-02"},{"SOURCE_ROW_NUMBER":"1133682","VIOLATION_NO":"7446750","VIOLATION_ISSUE_DT":"12/01/2009","SIG_SUB":"Y","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/02/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"1133681","VIOLATION_NO":"7446749","VIOLATION_ISSUE_DT":"12/01/2009","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/02/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"1133680","VIOLATION_NO":"7446748","VIOLATION_ISSUE_DT":"12/01/2009","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/01/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-12-01"},{"SOURCE_ROW_NUMBER":"1133679","VIOLATION_NO":"7446747","VIOLATION_ISSUE_DT":"11/30/2009","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-11-30"},{"SOURCE_ROW_NUMBER":"1133678","VIOLATION_NO":"7446746","VIOLATION_ISSUE_DT":"11/25/2009","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/30/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-11-25"}]}],"safety":{"href":"/api/v1/mines/1519246/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519246/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 72.630","heading":"Drill dust control at underground areas of underground mines.","id":"72.630","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-72/subpart-E/section-72.630","part":"72","partHeading":"PART 72—HEALTH STANDARDS FOR COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Miscellaneous","text":"(a) Dust resulting from drilling in rock shall be controlled by use of permissible dust collectors, or by water, or water with a wetting agent, or by ventilation, or by any other method or device approved by the Secretary that is as effective in controlling the dust.\n\n(b) Dust collectors. Dust collectors shall be maintained in permissible and operating condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling in Coal Mines of this title or under Bureau of Mines Schedule 25B are permissible dust collectors for the purpose of this section.\n\n(c) Water control. Water used to control dust from drilling rock shall be applied through a hollow drill steel or stem or by the flooding of vertical drill holes in the floor.\n\n(d) Ventilation control. To adequately control dust from drilling rock, the air current shall be so directed that the dust is readily dispersed and carried away from the drill operator or any other miners in the area.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","heading":"Short circuit protection; use of fuses; approval by the Secretary.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-2","part":"75","subchapter":"O","subpart":"G","id":"75.601-2","citation":"30 CFR 75.601-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519246","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}