{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519078","name":"Blackwood","status":"Abandoned and Sealed","status_date":"2008-10-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Letcher","nearest_town":"Partridge","operator_id":"P21182","operator_name":"Cumberland River Coal Co., Inc.","controller_id":"C15863","controller_name":"Jeffery A  Hoops","district":"C07","office":"Harlan KY Field Office","employees":0,"latitude":37.035277,"longitude":-82.826666},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":317},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519078","name":"Blackwood"},"operator":{"type":"operator","id":"P21182","name":"Cumberland River Coal Co., Inc."},"controller":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"mine","id":"1519078","name":"Blackwood"},"validFrom":"1987-05-18","validTo":"2005-12-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519078|C00012|1987-05-18|2005-12-11"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"mine","id":"1519078","name":"Blackwood"},"validFrom":"2005-12-12","validTo":"2017-09-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519078|C15561|2005-12-12|2017-09-13"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21182","name":"Cumberland River Coal Co., Inc."},"object":{"type":"mine","id":"1519078","name":"Blackwood"},"validFrom":"2007-01-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519078|P21182|2007-01-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"operator","id":"P21182","name":"Cumberland River Coal Co., Inc."},"validFrom":"2007-01-23","validTo":"2005-12-11","current":false,"derived":true,"evidenceMineId":"1519078","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519078|P21182|2007-01-23|C00012|1987-05-18|43325"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"operator","id":"P21182","name":"Cumberland River Coal Co., Inc."},"validFrom":"2007-01-23","validTo":"2017-09-13","current":false,"derived":true,"evidenceMineId":"1519078","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519078|P21182|2007-01-23|C15561|2005-12-12|96047"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"mine","id":"1519078","name":"Blackwood"},"validFrom":"2017-09-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519078|C15863|2017-09-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"operator","id":"P21182","name":"Cumberland River Coal Co., Inc."},"validFrom":"2017-09-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519078","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519078|P21182|2007-01-23|C15863|2017-09-14|97303"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2008-02-05","lastDate":"2008-02-08","metrics":{"daysLost":0,"injuries":0,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"242529","DOCUMENT_NO":"220080430046","ACCIDENT_DT":"02/08/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall in the #7 heading between crosscuts #17 and #19. Fall was approximately 100' ling and from 1' to 10 feet in height. Most equipment had been moved from the section prior to the fall and the rest of the equipment is now removed. Section has been abandoned.","sourceDate":"2008-02-08"},{"SOURCE_ROW_NUMBER":"194952","DOCUMENT_NO":"220080430045","ACCIDENT_DT":"02/06/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall in #6 heading between intersection #18 and #19. Fall was 50 feet long and 3 to 8 feet high. Area was cribbed off and equipment was being moved off the section.","sourceDate":"2008-02-06"},{"SOURCE_ROW_NUMBER":"125984","DOCUMENT_NO":"220080430047","ACCIDENT_DT":"02/05/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall at 18 crosscut between #4 and #5 entries. Fall was approximately 10 feet long and between 3 and 5 feet thick. Area was cribbed off.","sourceDate":"2008-02-05"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2008-10-30","lastDate":"2008-10-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":55,"firstDate":"2007-06-07","lastDate":"2008-02-20","metrics":{"ss":23,"delinquent":55,"recentRows":0,"paidPenalty":18145.19,"proposedPenalty":30686,"currentAssessment":30686},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1149379","VIOLATION_NO":"7505196","ISSUE_DT":"02/20/2008","CFR_STANDARD_CD":"75.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-20"},{"SOURCE_ROW_NUMBER":"1149378","VIOLATION_NO":"7505193","ISSUE_DT":"02/13/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"499.00","CURRENT_ASSESSMENT_AMT":"499.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"1149377","VIOLATION_NO":"7505192","ISSUE_DT":"02/13/2008","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"1149376","VIOLATION_NO":"7505191","ISSUE_DT":"02/13/2008","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"1149375","VIOLATION_NO":"7505190","ISSUE_DT":"02/12/2008","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1149374","VIOLATION_NO":"7505189","ISSUE_DT":"02/12/2008","CFR_STANDARD_CD":"75.604(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1149373","VIOLATION_NO":"7505188","ISSUE_DT":"02/12/2008","CFR_STANDARD_CD":"75.517","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1149372","VIOLATION_NO":"7505187","ISSUE_DT":"02/12/2008","CFR_STANDARD_CD":"75.364(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1149371","VIOLATION_NO":"7505186","ISSUE_DT":"02/08/2008","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-08"},{"SOURCE_ROW_NUMBER":"1149370","VIOLATION_NO":"7505185","ISSUE_DT":"02/08/2008","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-02-08"},{"SOURCE_ROW_NUMBER":"1149351","VIOLATION_NO":"7505166","ISSUE_DT":"12/19/2007","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-12-19"},{"SOURCE_ROW_NUMBER":"1149350","VIOLATION_NO":"7505165","ISSUE_DT":"12/19/2007","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-12-19"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2009-11-03","lastDate":"2009-11-03","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":14373,"originalPenalty":14373},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"14797","VIOLATION_NO":"7502698","DOCKET_NO":"KENT 2008-148","DECISION_DT":"11/03/2009","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"14373.00","DECISION_PENALTY_AMT":"14373.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2009-11-03"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":66,"firstDate":"2007-06-20","lastDate":"2008-04-02","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":11,"validSamples":55,"maxConcentration":4.232,"concentrationTotal":35.046},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"242399","CASS_NUM":"50916526","SMP_TAKEN_DT":"4/2/2008","CONC":".159","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-02"},{"SOURCE_ROW_NUMBER":"1144547","CASS_NUM":"50916550","SMP_TAKEN_DT":"4/1/2008","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-01"},{"SOURCE_ROW_NUMBER":"868816","CASS_NUM":"50916551","SMP_TAKEN_DT":"4/1/2008","CONC":"2.354","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-01"},{"SOURCE_ROW_NUMBER":"1442997","CASS_NUM":"50916520","SMP_TAKEN_DT":"3/31/2008","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-31"},{"SOURCE_ROW_NUMBER":"1092158","CASS_NUM":"50916571","SMP_TAKEN_DT":"3/31/2008","CONC":".399","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"MMU NOT IN PRODUCING STATUS","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-31"},{"SOURCE_ROW_NUMBER":"1457919","CASS_NUM":"50916567","SMP_TAKEN_DT":"3/21/2008","CONC":".112","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-03-21"},{"SOURCE_ROW_NUMBER":"158683","CASS_NUM":"50858959","SMP_TAKEN_DT":"2/28/2008","CONC":".31","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-28"},{"SOURCE_ROW_NUMBER":"1353082","CASS_NUM":"50858942","SMP_TAKEN_DT":"2/27/2008","CONC":".572","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DISCARDED SAMPLE (TOO OLD)","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-27"},{"SOURCE_ROW_NUMBER":"416619","CASS_NUM":"50858948","SMP_TAKEN_DT":"2/27/2008","CONC":".631","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DISCARDED SAMPLE (TOO OLD)","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-27"},{"SOURCE_ROW_NUMBER":"1541730","CASS_NUM":"50858952","SMP_TAKEN_DT":"2/5/2008","CONC":".257","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"600745","CASS_NUM":"50858924","SMP_TAKEN_DT":"2/5/2008","CONC":".938","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID PRODUCTION","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"397784","CASS_NUM":"50858946","SMP_TAKEN_DT":"2/4/2008","CONC":".372","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-02-04"}]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":1,"firstDate":"2007-09-24","lastDate":"2007-09-24","metrics":{"decisions":1,"ssChanged":1,"recentRows":0,"decisionPenalty":14373,"proposedPenalty":14373},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"117072","CITATION_NO":"7502698","CITATION_ISSUE_DT":"09/24/2007","DOCKET_NO":"KENT 2008-148","DECISION_DT":"11/03/2009","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"14373.00","DECISION_PENALTY_AMT":"14373.00","sourceDate":"2007-09-24"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":70,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":16,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2007-01-23","lastDate":"2007-01-23","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":12,"firstDate":"2007-03-26","lastDate":"2008-09-17","metrics":{"inspectors":34,"recentRows":0,"onSiteHours":332.75,"inspectionHours":576.75,"inspectionSamples":64},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1096359","EVENT_NO":"4240720","INSPECTION_BEGIN_DT":"09/17/2008","INSPECTION_END_DT":"09/23/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"8.75","sourceDate":"2008-09-17"},{"SOURCE_ROW_NUMBER":"891198","EVENT_NO":"4444460","INSPECTION_BEGIN_DT":"04/10/2008","INSPECTION_END_DT":"05/29/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"28","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2008-04-10"},{"SOURCE_ROW_NUMBER":"486974","EVENT_NO":"4240326","INSPECTION_BEGIN_DT":"03/19/2008","INSPECTION_END_DT":"03/19/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"13.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2008-03-19"},{"SOURCE_ROW_NUMBER":"1093198","EVENT_NO":"4240509","INSPECTION_BEGIN_DT":"02/07/2008","INSPECTION_END_DT":"03/06/2008","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"23.25","SUM_TOTAL_ON_SITE_HOURS":"17.75","sourceDate":"2008-02-07"},{"SOURCE_ROW_NUMBER":"969067","EVENT_NO":"4240508","INSPECTION_BEGIN_DT":"02/05/2008","INSPECTION_END_DT":"03/12/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"139.75","SUM_TOTAL_ON_SITE_HOURS":"78.25","sourceDate":"2008-02-05"},{"SOURCE_ROW_NUMBER":"715463","EVENT_NO":"4442211","INSPECTION_BEGIN_DT":"01/16/2008","INSPECTION_END_DT":"01/16/2008","ACTIVITY_CODE":"E22","ACTIVITY":"Health Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10.5","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"163984","EVENT_NO":"4240503","INSPECTION_BEGIN_DT":"11/14/2007","INSPECTION_END_DT":"12/31/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"107.5","SUM_TOTAL_ON_SITE_HOURS":"63","sourceDate":"2007-11-14"},{"SOURCE_ROW_NUMBER":"370404","EVENT_NO":"4241468","INSPECTION_BEGIN_DT":"07/09/2007","INSPECTION_END_DT":"09/26/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"109.5","SUM_TOTAL_ON_SITE_HOURS":"65","sourceDate":"2007-07-09"},{"SOURCE_ROW_NUMBER":"401542","EVENT_NO":"4241466","INSPECTION_BEGIN_DT":"07/03/2007","INSPECTION_END_DT":"07/03/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2007-07-03"},{"SOURCE_ROW_NUMBER":"568618","EVENT_NO":"4225420","INSPECTION_BEGIN_DT":"06/18/2007","INSPECTION_END_DT":"06/18/2007","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2007-06-18"},{"SOURCE_ROW_NUMBER":"239700","EVENT_NO":"4228459","INSPECTION_BEGIN_DT":"04/03/2007","INSPECTION_END_DT":"06/27/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"82","SUM_TOTAL_ON_SITE_HOURS":"54","sourceDate":"2007-04-03"},{"SOURCE_ROW_NUMBER":"624794","EVENT_NO":"4228456","INSPECTION_BEGIN_DT":"03/26/2007","INSPECTION_END_DT":"03/27/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"17.75","SUM_TOTAL_ON_SITE_HOURS":"9.5","sourceDate":"2007-03-26"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008-Q3":{"hours":0,"employees":0,"production":0},"2008-Q2":{"hours":2226,"employees":5,"production":7199},"2008-Q1":{"hours":24508,"employees":37,"production":37311},"2007-Q4":{"hours":21813,"employees":36,"production":63617},"2007-Q3":{"hours":18626,"employees":35,"production":49711},"2007-Q2":{"hours":4808,"employees":10,"production":9871}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":45247,"employees":27,"production":123199},"2008":{"hours":26734,"employees":22,"production":44510}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":12,"firstDate":"2007-09-24","lastDate":"2008-01-16","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":801,"pelDoseTotal":578},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94724","EVENT_NO":"4442211","SURVEY_DATE":"01/16/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"51","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"94723","EVENT_NO":"4442211","SURVEY_DATE":"01/16/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"63","PEL_DOSE_90":"36","SURVEY_TYPE":"I","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"94722","EVENT_NO":"4442211","SURVEY_DATE":"01/16/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"25","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"94721","EVENT_NO":"4442211","SURVEY_DATE":"01/16/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"69","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"94720","EVENT_NO":"4442211","SURVEY_DATE":"01/16/2008","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"107","PEL_DOSE_90":"87","SURVEY_TYPE":"I","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"94717","EVENT_NO":"4240503","SURVEY_DATE":"11/16/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"83","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2007-11-16"},{"SOURCE_ROW_NUMBER":"94716","EVENT_NO":"4240503","SURVEY_DATE":"11/16/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"85","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2007-11-16"},{"SOURCE_ROW_NUMBER":"94715","EVENT_NO":"4240503","SURVEY_DATE":"11/16/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"95","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2007-11-16"},{"SOURCE_ROW_NUMBER":"94714","EVENT_NO":"4240503","SURVEY_DATE":"11/16/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"57","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2007-11-16"},{"SOURCE_ROW_NUMBER":"94713","EVENT_NO":"4240503","SURVEY_DATE":"11/16/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"98","PEL_DOSE_90":"83","SURVEY_TYPE":"I","sourceDate":"2007-11-16"},{"SOURCE_ROW_NUMBER":"94719","EVENT_NO":"4241468","SURVEY_DATE":"09/24/2007","OCCUPATION_CD_DESC":"SUPPLY MAN","MACHINE_CD":"38","MANUFACTURER_CD":"033","ACT_DOSE_85":"21","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"94718","EVENT_NO":"4241468","SURVEY_DATE":"09/24/2007","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"47","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2007-09-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":3,"firstDate":"2007-09-20","lastDate":"2008-01-16","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.3,"validSamples":3,"quartzPctTotal":15.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"123264","CASSETTE_NO":"57720099","SAMPLE_DT":"01/16/2008","QUARTZ_PCT":"04.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"157127","CASSETTE_NO":"57688483","SAMPLE_DT":"11/16/2007","QUARTZ_PCT":"05.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-11-16"},{"SOURCE_ROW_NUMBER":"149408","CASSETTE_NO":"57693324","SAMPLE_DT":"09/20/2007","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-09-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":58,"firstDate":"2007-06-07","lastDate":"2008-03-19","metrics":{"ss":23,"amountDue":30686,"contested":1,"amountPaid":18145.19,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":30686},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1111947","VIOLATION_NO":"7523766","VIOLATION_ISSUE_DT":"03/19/2008","PART_SECTION":"75.1403-5(g)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"04/10/2008","CONTESTED_IND":"N","sourceDate":"2008-03-19"},{"SOURCE_ROW_NUMBER":"1111945","VIOLATION_NO":"7505196","VIOLATION_ISSUE_DT":"02/20/2008","SIG_SUB":"N","PART_SECTION":"75.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/20/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-02-20"},{"SOURCE_ROW_NUMBER":"1111944","VIOLATION_NO":"7505193","VIOLATION_ISSUE_DT":"02/13/2008","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/15/2008","PROPOSED_PENALTY":"499","AMOUNT_DUE":"499","AMOUNT_PAID":"499","CONTESTED_IND":"N","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"1111943","VIOLATION_NO":"7505192","VIOLATION_ISSUE_DT":"02/13/2008","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/13/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"1111942","VIOLATION_NO":"7505191","VIOLATION_ISSUE_DT":"02/13/2008","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/15/2008","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2008-02-13"},{"SOURCE_ROW_NUMBER":"1111941","VIOLATION_NO":"7505190","VIOLATION_ISSUE_DT":"02/12/2008","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2008","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1111940","VIOLATION_NO":"7505189","VIOLATION_ISSUE_DT":"02/12/2008","SIG_SUB":"N","PART_SECTION":"75.604(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1111939","VIOLATION_NO":"7505188","VIOLATION_ISSUE_DT":"02/12/2008","SIG_SUB":"Y","PART_SECTION":"75.517","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2008","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1111938","VIOLATION_NO":"7505187","VIOLATION_ISSUE_DT":"02/12/2008","SIG_SUB":"N","PART_SECTION":"75.364(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"04/10/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-02-12"},{"SOURCE_ROW_NUMBER":"1111937","VIOLATION_NO":"7505186","VIOLATION_ISSUE_DT":"02/08/2008","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/20/2008","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2008-02-08"},{"SOURCE_ROW_NUMBER":"1111936","VIOLATION_NO":"7505185","VIOLATION_ISSUE_DT":"02/08/2008","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2008","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"745","CONTESTED_IND":"N","sourceDate":"2008-02-08"},{"SOURCE_ROW_NUMBER":"1111946","VIOLATION_NO":"7505184","VIOLATION_ISSUE_DT":"02/07/2008","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"04/10/2008","CONTESTED_IND":"N","sourceDate":"2008-02-07"}]}],"safety":{"href":"/api/v1/mines/1519078/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519078/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-5","heading":"Criteria—Belt conveyors.","id":"75.1403-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Positive-acting stop controls should be installed along all belt conveyors used to transport men, and such controls should be readily accessible and maintained so that the belt can be stopped or started at any location.\n\n(b) Belt conveyors used for regularly scheduled mantrips should be stopped while men are loading or unloading.\n\n(c) All belt conveyors used for the transportation of persons should have a minimum vertical clearance of 18 inches from the nearest overhead projection when measured from the edge of the belt and there should be at least 36 inches of side clearance where men board or leave such belt conveyors.\n\n(d) When men are being transported on regularly scheduled mantrips on belt conveyors the belt speed should not exceed 300 feet per minute when the vertical clearance is less than 24 inches, and should not exceed 350 feet per minute when the vertical clearance is 24 inches or more.\n\n(e) Adequate illumination including colored lights or reflective signs should be installed at all loading and unloading stations. Such colored lights and reflective signs should be so located as to be observable to all persons riding the belt conveyor.\n\n(f) After supplies have been transported on belt conveyors such belts should be examined for unsafe conditions prior to the transportation of men on regularly scheduled mantrips, and belt conveyors should be clear before men are transported.\n\n(g) A clear travelway at least 24 inches wide should be provided on both sides of all belt conveyors installed after March 30, 1970. Where roof supports are installed within 24 inches of a belt conveyor, a clear travelway at least 24 inches wide should be provided on the side of such support farthest from the conveyor.\n\n(h) On belt conveyors that do not transport men, stop and start controls should be installed at intervals not to exceed 1,000 feet. Such controls should be properly installed and positioned so as to be readily accessible.\n\n(i) Telephone or other suitable communications should be provided at points where men or supplies are regularly loaded on or unloaded from the belt conveyors.\n\n(j) Persons should not cross moving belt conveyors, except where suitable crossing facilities are provided.","occurrenceCount":1},{"chapter":"I","heading":"Underground storage, lubricating oil and grease.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1104","part":"75","subchapter":"O","subpart":"L","id":"75.1104","citation":"30 CFR 75.1104","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.517","heading":"Power wires and cables; insulation and protection.","id":"75.517","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.517","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nPower wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519078","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}