{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519063","name":"Panther Mine #4a","status":"Abandoned","status_date":"2014-03-19","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Harlan","nearest_town":"Cumberland","operator_id":"P24317","operator_name":"Panther Mining, LLC","controller_id":"0041211","controller_name":"Alpha Natural Resources, Inc.","district":"C07","office":"Harlan KY Field Office","employees":0,"latitude":36.955,"longitude":-83.005},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1377},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519063","name":"Panther Mine #4a"},"operator":{"type":"operator","id":"P24317","name":"Panther Mining, LLC"},"controller":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"mine","id":"1519063","name":"Panther Mine #4a"},"validFrom":"1999-09-01","validTo":"2010-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|C07082|1999-09-01|2010-04-18"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0077003","name":"Mill Branch Mining Inc"},"object":{"type":"mine","id":"1519063","name":"Panther Mine #4a"},"validFrom":"2006-11-21","validTo":"2008-02-17","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|0077003|2006-11-21|2008-02-17"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15881","name":"Jack H Ealy et al"},"object":{"type":"mine","id":"1519063","name":"Panther Mine #4a"},"validFrom":"2006-11-21","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|C15881|2006-11-21|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15881","name":"Jack H Ealy et al"},"object":{"type":"operator","id":"0077003","name":"Mill Branch Mining Inc"},"validFrom":"2006-11-21","validTo":"2008-02-17","current":false,"derived":true,"evidenceMineId":"1519063","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|0077003|2006-11-21|C15881|2006-11-21|97411"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15881","name":"John D North et al -  JackrockLLC only8/27/99-5/3/04"},"object":{"type":"operator","id":"0077003","name":"Mill Branch Mining Inc"},"validFrom":"2006-11-21","validTo":"2008-02-17","current":false,"derived":true,"evidenceMineId":"1519063","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|0077003|2006-11-21|C15881|2006-11-21|97412"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15881","name":"Ralph  Napier et al"},"object":{"type":"operator","id":"0077003","name":"Mill Branch Mining Inc"},"validFrom":"2006-11-21","validTo":"2008-02-17","current":false,"derived":true,"evidenceMineId":"1519063","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|0077003|2006-11-21|C15881|2006-11-21|97413"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24317","name":"Panther Mining, LLC"},"object":{"type":"mine","id":"1519063","name":"Panther Mine #4a"},"validFrom":"2008-02-18","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|P24317|2008-02-18|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C07082","name":"Cumberland Resources Corporation"},"object":{"type":"operator","id":"P24317","name":"Panther Mining, LLC"},"validFrom":"2008-02-18","validTo":"2010-04-18","current":false,"derived":true,"evidenceMineId":"1519063","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|P24317|2008-02-18|C07082|1999-09-01|73736"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1519063","name":"Panther Mine #4a"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|C02508|2010-04-19|2011-05-31"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P24317","name":"Panther Mining, LLC"},"validFrom":"2010-04-19","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1519063","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|P24317|2008-02-18|C02508|2010-04-19|59571"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1519063","name":"Panther Mine #4a"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|0041211|2011-06-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P24317","name":"Panther Mining, LLC"},"validFrom":"2011-06-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519063","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519063|P24317|2008-02-18|0041211|2011-06-01|2259"}}],"coverage":{"historyRecords":6,"edgeCount":12,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":20,"firstDate":"2007-03-25","lastDate":"2010-01-25","metrics":{"daysLost":370,"injuries":10,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"113220","DOCUMENT_NO":"220100280045","ACCIDENT_DT":"01/25/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"On 1/25/10 mine examiner found a roof fall in #5 entry between #1 and #2 crosscuts. This is a continuation of a previous fall. Fall approx 20' X 20' X 7'. Area timbered and dangered off. No ventilation interuption, no injuries. This is an idle section. Fall was 1 BK inby spad #730.","sourceDate":"2010-01-25"},{"SOURCE_ROW_NUMBER":"255386","DOCUMENT_NO":"220100280044","ACCIDENT_DT":"01/22/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Roof fall found during weekly exam. The fall was on old 002 section in belt entry starting in intersection @ BK #2 and going to BK #3 inby corner. Fall 1 BK inby spad #170 to 18K outby spad #193. Area cribbed and dangered off on all sides. This is an idle section. No injuries.  Ventilation still passing through area. Fall found by EE A-70-01. Fall approx 100' X 19' X 7' in size.","sourceDate":"2010-01-22"},{"SOURCE_ROW_NUMBER":"229566","DOCUMENT_NO":"220100080023","ACCIDENT_DT":"01/05/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall was found by foreman at break #3 between the #3 and #4 entry. The roof fall is approx 20'L X 16'W X 6'T. The roof fall has been cribbed and dangered off.","sourceDate":"2010-01-05"},{"SOURCE_ROW_NUMBER":"238136","DOCUMENT_NO":"220091960042","ACCIDENT_DT":"07/13/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"During weekly exam, the mine examiner found a roof fall on old 2 belt. (Not working section). Fall was in #3 entry on roadway @ 34 cc in intersection. Fall approx 20' x 20' x 4' thick. Fall is cribbed off and dangered off. A-1312-78","sourceDate":"2009-07-13"},{"SOURCE_ROW_NUMBER":"160719","DOCUMENT_NO":"220091800041","ACCIDENT_DT":"06/23/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"63","NARRATIVE":"Employee was riding a mantrip that ran over a submerged crib block. Crib block flipped up striking employee in lower back.","sourceDate":"2009-06-23"},{"SOURCE_ROW_NUMBER":"246818","DOCUMENT_NO":"220091540032","ACCIDENT_DT":"05/22/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"On 5/22/09, during his weekly exam, Employee found a roof fall in #2 entry between 41cc and 42cc on abandoned section. Fall was approx. 60' long x 20' wide x 4 1/2' thick. This fall did not interfere with ventilation to working section.","sourceDate":"2009-05-22"},{"SOURCE_ROW_NUMBER":"125983","DOCUMENT_NO":"220091380064","ACCIDENT_DT":"05/06/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Was drilling a hole for a roof bolt when steel stopped up. He hit steel with a drill wrench trying to unstop it. Wrench ricocheted back striking him in the right cheek.","sourceDate":"2009-05-06"},{"SOURCE_ROW_NUMBER":"44515","DOCUMENT_NO":"220091350025","ACCIDENT_DT":"05/05/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Mine superintendent found a roof fall during is weekly examinations. Fall was at Bk 68 in # 1 entry. Fall was approx. 18' - 20' wide x 45' - 50' long x 5'to 6' high. Area was timbered and dangered off. Fall was on old inactive section.","sourceDate":"2009-05-05"},{"SOURCE_ROW_NUMBER":"233829","DOCUMENT_NO":"220091330044","ACCIDENT_DT":"05/04/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was moving a CLA on miner, when it slid down, catching his little finger which resulted in a laceration.","sourceDate":"2009-05-04"},{"SOURCE_ROW_NUMBER":"100299","DOCUMENT_NO":"220091240069","ACCIDENT_DT":"04/17/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was roof bolting the No 12 entry lt. brk. when a small piece of draw rock fell out hitting the employee on the nose and lip, requiring (6) stitches.","sourceDate":"2009-04-17"},{"SOURCE_ROW_NUMBER":"199309","DOCUMENT_NO":"220090400062","ACCIDENT_DT":"01/31/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall was found by a employee while he was making his weekly, at break 65 in between the #2 and #3 entry in the return. The roof fall is approx. 30'long x 19' wide x 7' thick. The roof fall is not on the active section and is timbered and danger off.","sourceDate":"2009-01-31"},{"SOURCE_ROW_NUMBER":"83281","DOCUMENT_NO":"220083380036","ACCIDENT_DT":"11/26/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"Employee found the roof fall on 11/26/2008. The fall is in the #2 entry between break #62 and 63. The roof fall is not on the active section. Roof fall is approx 40' long x 18' wide x 5'-6' thick. Roof faall has been timbered and dangered off.","sourceDate":"2008-11-26"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-03-19","lastDate":"2014-03-19","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":351,"firstDate":"2006-12-13","lastDate":"2014-02-24","metrics":{"ss":117,"delinquent":351,"recentRows":0,"paidPenalty":42196,"proposedPenalty":91812,"currentAssessment":84837},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1992279","VIOLATION_NO":"8396677","ISSUE_DT":"02/24/2014","CFR_STANDARD_CD":"75.1711","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-24"},{"SOURCE_ROW_NUMBER":"1489786","VIOLATION_NO":"8404412","ISSUE_DT":"08/23/2013","CFR_STANDARD_CD":"75.1204","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-08-23"},{"SOURCE_ROW_NUMBER":"1448187","VIOLATION_NO":"8360112","ISSUE_DT":"12/30/2009","CFR_STANDARD_CD":"75.364(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"138.00","CURRENT_ASSESSMENT_AMT":"138.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-12-30"},{"SOURCE_ROW_NUMBER":"1449410","VIOLATION_NO":"8354242","ISSUE_DT":"07/22/2009","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"157.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"1449409","VIOLATION_NO":"8354241","ISSUE_DT":"07/22/2009","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"157.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"1449408","VIOLATION_NO":"8354240","ISSUE_DT":"07/17/2009","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"497.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1449407","VIOLATION_NO":"8354239","ISSUE_DT":"07/17/2009","CFR_STANDARD_CD":"75.1100-2(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"127.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1449406","VIOLATION_NO":"8354238","ISSUE_DT":"07/17/2009","CFR_STANDARD_CD":"75.523-3(c)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1449405","VIOLATION_NO":"8354237","ISSUE_DT":"07/17/2009","CFR_STANDARD_CD":"75.1106-3(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1449404","VIOLATION_NO":"8354236","ISSUE_DT":"07/15/2009","CFR_STANDARD_CD":"75.1909(b)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"527.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-15"},{"SOURCE_ROW_NUMBER":"1449403","VIOLATION_NO":"8354232","ISSUE_DT":"07/14/2009","CFR_STANDARD_CD":"75.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-14"},{"SOURCE_ROW_NUMBER":"1449402","VIOLATION_NO":"8354231","ISSUE_DT":"07/08/2009","CFR_STANDARD_CD":"75.1101-8(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-08"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":50,"firstDate":"2008-10-14","lastDate":"2011-07-18","metrics":{"appeals":0,"decisions":50,"recentRows":0,"decisionPenalty":27681,"originalPenalty":41383},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"231319","VIOLATION_NO":"8329666","DOCKET_NO":"KENT 2009-125","DECISION_DT":"07/18/2011","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2011-07-18"},{"SOURCE_ROW_NUMBER":"231058","VIOLATION_NO":"8329665","DOCKET_NO":"KENT 2009-125","DECISION_DT":"07/18/2011","DECISION_TYPE_CODE_DESC":"Dismissal","ORIGINAL_PENALTY_AMT":"2341.00","DECISION_PENALTY_AMT":"2341.00","JUDGE_FIRST_NAME":"N/A","sourceDate":"2011-07-18"},{"SOURCE_ROW_NUMBER":"225193","VIOLATION_NO":"8329639","DOCKET_NO":"KENT 2008-1329","DECISION_DT":"06/15/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"225049","VIOLATION_NO":"8329633","DOCKET_NO":"KENT 2008-1329","DECISION_DT":"06/15/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"224219","VIOLATION_NO":"8329634","DOCKET_NO":"KENT 2008-1328","DECISION_DT":"06/15/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"499.00","DECISION_PENALTY_AMT":"375.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"224124","VIOLATION_NO":"8329614","DOCKET_NO":"KENT 2008-1329","DECISION_DT":"06/15/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"100.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"26612","VIOLATION_NO":"8329643","DOCKET_NO":"KENT 2008-1329","DECISION_DT":"06/15/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"26611","VIOLATION_NO":"8329635","DOCKET_NO":"KENT 2008-1329","DECISION_DT":"06/15/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"460.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-06-15"},{"SOURCE_ROW_NUMBER":"257701","VIOLATION_NO":"8354241","DOCKET_NO":"KENT 2010-188","DECISION_DT":"03/28/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"157.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-03-28"},{"SOURCE_ROW_NUMBER":"46279","VIOLATION_NO":"8354242","DOCKET_NO":"KENT 2010-188","DECISION_DT":"03/28/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"157.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2011-03-28"},{"SOURCE_ROW_NUMBER":"28662","VIOLATION_NO":"8329647","DOCKET_NO":"KENT 2008-1619","DECISION_DT":"01/31/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"2000.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Gary","JUDGE_LAST_NAME":"Melick","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"248837","VIOLATION_NO":"8336191","DOCKET_NO":"KENT 2009-1229","DECISION_DT":"10/28/2010","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"468.00","JUDGE_FIRST_NAME":"Alan","JUDGE_LAST_NAME":"Paez","sourceDate":"2010-10-28"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":209,"firstDate":"2007-06-18","lastDate":"2009-07-17","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":51,"validSamples":158,"maxConcentration":6.611,"concentrationTotal":161.301},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1344710","CASS_NUM":"51033521","SMP_TAKEN_DT":"7/17/2009","CONC":"1.374","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1189420","CASS_NUM":"51024172","SMP_TAKEN_DT":"7/16/2009","CONC":"1.178","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-07-16"},{"SOURCE_ROW_NUMBER":"282760","CASS_NUM":"51024170","SMP_TAKEN_DT":"7/15/2009","CONC":".644","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-07-15"},{"SOURCE_ROW_NUMBER":"223199","CASS_NUM":"51024158","SMP_TAKEN_DT":"7/14/2009","CONC":".598","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-07-14"},{"SOURCE_ROW_NUMBER":"552759","CASS_NUM":"51024174","SMP_TAKEN_DT":"7/13/2009","CONC":"2.064","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-07-13"},{"SOURCE_ROW_NUMBER":"1180116","CASS_NUM":"51015301","SMP_TAKEN_DT":"6/23/2009","CONC":".122","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-06-23"},{"SOURCE_ROW_NUMBER":"415504","CASS_NUM":"51024203","SMP_TAKEN_DT":"5/15/2009","CONC":".431","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-15"},{"SOURCE_ROW_NUMBER":"1431162","CASS_NUM":"51024221","SMP_TAKEN_DT":"5/14/2009","CONC":".684","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-14"},{"SOURCE_ROW_NUMBER":"206181","CASS_NUM":"51016462","SMP_TAKEN_DT":"5/13/2009","CONC":".56","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-13"},{"SOURCE_ROW_NUMBER":"15108","CASS_NUM":"51016510","SMP_TAKEN_DT":"5/12/2009","CONC":".435","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"CITATION SAMPLE/COMPLIANCE DURING FIRST SEVEN DAYS OF CYCLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-12"},{"SOURCE_ROW_NUMBER":"1132256","CASS_NUM":"51016461","SMP_TAKEN_DT":"5/11/2009","CONC":".3","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"CITATION SAMPLE/COMPLIANCE DURING FIRST SEVEN DAYS OF CYCLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"1120172","CASS_NUM":"51015276","SMP_TAKEN_DT":"5/5/2009","CONC":".334","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"CITATION SAMPLE/COMPLIANCE DURING FIRST SEVEN DAYS OF CYCLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-05-05"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":2,"firstDate":"2008-07-15","lastDate":"2008-09-10","metrics":{"linkedIssuances":2},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":50,"firstDate":"2008-03-04","lastDate":"2009-07-22","metrics":{"decisions":50,"ssChanged":2,"recentRows":0,"decisionPenalty":27681,"proposedPenalty":41383},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"240505","CITATION_NO":"8354242","CITATION_ISSUE_DT":"07/22/2009","DOCKET_NO":"KENT 2010-188","DECISION_DT":"03/28/2011","CFR_STANDARD_CODE":"77.1606(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"157.00","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"127104","CITATION_NO":"8354241","CITATION_ISSUE_DT":"07/22/2009","DOCKET_NO":"KENT 2010-188","DECISION_DT":"03/28/2011","CFR_STANDARD_CODE":"77.404(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"157.00","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"295993","CITATION_NO":"8354240","CITATION_ISSUE_DT":"07/17/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.604(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"497.00","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"239267","CITATION_NO":"8354239","CITATION_ISSUE_DT":"07/17/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.1100-2(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"127.00","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"239484","CITATION_NO":"8354236","CITATION_ISSUE_DT":"07/15/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.1909(b)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"527.00","sourceDate":"2009-07-15"},{"SOURCE_ROW_NUMBER":"410786","CITATION_NO":"8354229","CITATION_ISSUE_DT":"07/08/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.1731(b)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":"117.00","sourceDate":"2009-07-08"},{"SOURCE_ROW_NUMBER":"183553","CITATION_NO":"8354230","CITATION_ISSUE_DT":"07/08/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.1731(a)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"117.00","DECISION_PENALTY_AMT":"117.00","sourceDate":"2009-07-08"},{"SOURCE_ROW_NUMBER":"295417","CITATION_NO":"8354228","CITATION_ISSUE_DT":"07/07/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.380(d)(7)(vi)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"308.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2009-07-07"},{"SOURCE_ROW_NUMBER":"353121","CITATION_NO":"8354225","CITATION_ISSUE_DT":"07/06/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"634.00","DECISION_PENALTY_AMT":"634.00","sourceDate":"2009-07-06"},{"SOURCE_ROW_NUMBER":"296894","CITATION_NO":"8354222","CITATION_ISSUE_DT":"07/06/2009","DOCKET_NO":"KENT 2009-1558","DECISION_DT":"07/26/2010","CFR_STANDARD_CODE":"75.220(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","sourceDate":"2009-07-06"},{"SOURCE_ROW_NUMBER":"298063","CITATION_NO":"8354119","CITATION_ISSUE_DT":"06/17/2009","DOCKET_NO":"KENT 2009-1471","DECISION_DT":"07/14/2010","CFR_STANDARD_CODE":"75.333(b)(3)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"176.00","sourceDate":"2009-06-17"},{"SOURCE_ROW_NUMBER":"297327","CITATION_NO":"8337124","CITATION_ISSUE_DT":"06/17/2009","DOCKET_NO":"KENT 2009-1471","DECISION_DT":"07/14/2010","CFR_STANDARD_CODE":"75.380(d)(1)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2009-06-17"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":173,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":27,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"2006-11-21","lastDate":"2008-02-18","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":38,"firstDate":"2006-12-13","lastDate":"2014-03-06","metrics":{"inspectors":88,"recentRows":0,"onSiteHours":1315.25,"inspectionHours":2119.5,"inspectionSamples":165},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1073845","EVENT_NO":"6429134","INSPECTION_BEGIN_DT":"03/06/2014","INSPECTION_END_DT":"03/06/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2014-03-06"},{"SOURCE_ROW_NUMBER":"80935","EVENT_NO":"6429133","INSPECTION_BEGIN_DT":"02/24/2014","INSPECTION_END_DT":"02/25/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2014-02-24"},{"SOURCE_ROW_NUMBER":"148680","EVENT_NO":"4467911","INSPECTION_BEGIN_DT":"08/23/2013","INSPECTION_END_DT":"02/24/2014","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":".5","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2013-08-23"},{"SOURCE_ROW_NUMBER":"155579","EVENT_NO":"4447039","INSPECTION_BEGIN_DT":"02/09/2010","INSPECTION_END_DT":"03/31/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"6.75","sourceDate":"2010-02-09"},{"SOURCE_ROW_NUMBER":"19136","EVENT_NO":"4447034","INSPECTION_BEGIN_DT":"12/08/2009","INSPECTION_END_DT":"12/31/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"12.75","sourceDate":"2009-12-08"},{"SOURCE_ROW_NUMBER":"1084279","EVENT_NO":"4447235","INSPECTION_BEGIN_DT":"07/06/2009","INSPECTION_END_DT":"09/01/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"100.5","SUM_TOTAL_ON_SITE_HOURS":"70","sourceDate":"2009-07-06"},{"SOURCE_ROW_NUMBER":"1126874","EVENT_NO":"4447233","INSPECTION_BEGIN_DT":"06/30/2009","INSPECTION_END_DT":"07/02/2009","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2009-06-30"},{"SOURCE_ROW_NUMBER":"1044229","EVENT_NO":"4446719","INSPECTION_BEGIN_DT":"06/22/2009","INSPECTION_END_DT":"06/25/2009","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"12","sourceDate":"2009-06-22"},{"SOURCE_ROW_NUMBER":"505521","EVENT_NO":"4446718","INSPECTION_BEGIN_DT":"06/17/2009","INSPECTION_END_DT":"06/30/2009","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"29.5","SUM_TOTAL_ON_SITE_HOURS":"15.5","sourceDate":"2009-06-17"},{"SOURCE_ROW_NUMBER":"443783","EVENT_NO":"4446717","INSPECTION_BEGIN_DT":"06/17/2009","INSPECTION_END_DT":"06/30/2009","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"57.5","SUM_TOTAL_ON_SITE_HOURS":"35","sourceDate":"2009-06-17"},{"SOURCE_ROW_NUMBER":"629340","EVENT_NO":"4447225","INSPECTION_BEGIN_DT":"04/01/2009","INSPECTION_END_DT":"04/27/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"127.5","SUM_TOTAL_ON_SITE_HOURS":"89","sourceDate":"2009-04-01"},{"SOURCE_ROW_NUMBER":"474546","EVENT_NO":"4447019","INSPECTION_BEGIN_DT":"03/13/2009","INSPECTION_END_DT":"03/13/2009","ACTIVITY_CODE":"E03","ACTIVITY":"103 (g) Written Notification Hazard Complaint Inspectio","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2009-03-13"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":35,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2010-Q1":{"hours":1317,"employees":3,"production":0},"2009-Q4":{"hours":1820,"employees":3,"production":0},"2009-Q3":{"hours":8829,"employees":13,"production":7501},"2009-Q2":{"hours":27692,"employees":45,"production":44724},"2009-Q1":{"hours":29457,"employees":41,"production":70626},"2008-Q4":{"hours":23910,"employees":37,"production":44827},"2008-Q3":{"hours":20357,"employees":30,"production":57587},"2008-Q2":{"hours":18998,"employees":33,"production":76043},"2008-Q1":{"hours":7151,"employees":32,"production":13606},"2007-Q4":{"hours":22733,"employees":44,"production":36075},"2007-Q3":{"hours":15401,"employees":32,"production":36185},"2007-Q2":{"hours":7790,"employees":17,"production":15557}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":10,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":46624,"employees":25,"production":88717},"2008":{"hours":70416,"employees":33,"production":192063},"2009":{"hours":67798,"employees":27,"production":122851},"2010":{"hours":1317,"employees":3,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":28,"firstDate":"2007-09-05","lastDate":"2009-02-02","metrics":{"recentRows":0,"doseOver100":11,"actDoseTotal":2579,"pelDoseTotal":2029},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94366","EVENT_NO":"4442227","SURVEY_DATE":"02/02/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"97","PEL_DOSE_90":"89","SURVEY_TYPE":"F","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"94365","EVENT_NO":"4442227","SURVEY_DATE":"02/02/2009","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"63","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"94364","EVENT_NO":"4442227","SURVEY_DATE":"02/02/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"47","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"94363","EVENT_NO":"4442227","SURVEY_DATE":"02/02/2009","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"58","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"94362","EVENT_NO":"4442227","SURVEY_DATE":"02/02/2009","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"115","PEL_DOSE_90":"98","SURVEY_TYPE":"I","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"94381","EVENT_NO":"4446706","SURVEY_DATE":"12/15/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"153","PEL_DOSE_90":"105","SURVEY_TYPE":"I","sourceDate":"2008-12-15"},{"SOURCE_ROW_NUMBER":"94380","EVENT_NO":"4446706","SURVEY_DATE":"12/15/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"119","PEL_DOSE_90":"99","SURVEY_TYPE":"I","sourceDate":"2008-12-15"},{"SOURCE_ROW_NUMBER":"94379","EVENT_NO":"4446706","SURVEY_DATE":"12/15/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2008-12-15"},{"SOURCE_ROW_NUMBER":"94378","EVENT_NO":"4446706","SURVEY_DATE":"12/15/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"49","SURVEY_TYPE":"I","sourceDate":"2008-12-15"},{"SOURCE_ROW_NUMBER":"94377","EVENT_NO":"4446706","SURVEY_DATE":"12/15/2008","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"137","PEL_DOSE_90":"114","SURVEY_TYPE":"I","sourceDate":"2008-12-15"},{"SOURCE_ROW_NUMBER":"94356","EVENT_NO":"4241355","SURVEY_DATE":"03/14/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2008-03-14"},{"SOURCE_ROW_NUMBER":"94355","EVENT_NO":"4241355","SURVEY_DATE":"03/14/2008","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"36","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2008-03-14"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":12,"firstDate":"2007-06-25","lastDate":"2008-12-22","metrics":{"recentRows":0,"voidSamples":1,"maxQuartzPct":7.8,"validSamples":11,"quartzPctTotal":69.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"100567","CASSETTE_NO":"57761863","SAMPLE_DT":"12/22/2008","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-12-22"},{"SOURCE_ROW_NUMBER":"62861","CASSETTE_NO":"57757836","SAMPLE_DT":"09/23/2008","QUARTZ_PCT":"05.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-09-23"},{"SOURCE_ROW_NUMBER":"26155","CASSETTE_NO":"57694549","SAMPLE_DT":"06/02/2008","QUARTZ_PCT":"04.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-06-02"},{"SOURCE_ROW_NUMBER":"113653","CASSETTE_NO":"57730348","SAMPLE_DT":"03/27/2008","QUARTZ_PCT":"05.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-27"},{"SOURCE_ROW_NUMBER":"51447","CASSETTE_NO":"57720004","SAMPLE_DT":"03/14/2008","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-14"},{"SOURCE_ROW_NUMBER":"90956","CASSETTE_NO":"57688289","SAMPLE_DT":"10/16/2007","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-10-16"},{"SOURCE_ROW_NUMBER":"11442","CASSETTE_NO":"57688278","SAMPLE_DT":"10/16/2007","QUARTZ_PCT":"05.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-10-16"},{"SOURCE_ROW_NUMBER":"93146","CASSETTE_NO":"57693181","SAMPLE_DT":"09/05/2007","QUARTZ_PCT":"06.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-09-05"},{"SOURCE_ROW_NUMBER":"90427","CASSETTE_NO":"57693172","SAMPLE_DT":"09/05/2007","QUARTZ_PCT":"07.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-09-05"},{"SOURCE_ROW_NUMBER":"87496","CASSETTE_NO":"50823980","SAMPLE_DT":"08/02/2007","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2007-08-02"},{"SOURCE_ROW_NUMBER":"139559","CASSETTE_NO":"57693506","SAMPLE_DT":"06/25/2007","QUARTZ_PCT":"05.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-25"},{"SOURCE_ROW_NUMBER":"65512","CASSETTE_NO":"57693517","SAMPLE_DT":"06/25/2007","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-25"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":364,"firstDate":"2006-12-13","lastDate":"2014-02-24","metrics":{"ss":117,"amountDue":84837,"contested":47,"amountPaid":42196,"recentRows":0,"section104d":3,"unterminated":6,"proposedPenalty":91812},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1110588","VIOLATION_NO":"8396677","VIOLATION_ISSUE_DT":"02/24/2014","SIG_SUB":"N","PART_SECTION":"75.1711","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/06/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-02-24"},{"SOURCE_ROW_NUMBER":"1110809","VIOLATION_NO":"8404412","VIOLATION_ISSUE_DT":"08/23/2013","SIG_SUB":"N","PART_SECTION":"75.1204","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"09/05/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-08-23"},{"SOURCE_ROW_NUMBER":"1110558","VIOLATION_NO":"8360134","VIOLATION_ISSUE_DT":"03/26/2010","PART_SECTION":"75.364(a)(1)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"03/06/2014","CONTESTED_IND":"N","sourceDate":"2010-03-26"},{"SOURCE_ROW_NUMBER":"1110902","VIOLATION_NO":"8360112","VIOLATION_ISSUE_DT":"12/30/2009","SIG_SUB":"N","PART_SECTION":"75.364(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"138","AMOUNT_DUE":"138","AMOUNT_PAID":"138","CONTESTED_IND":"N","sourceDate":"2009-12-30"},{"SOURCE_ROW_NUMBER":"1110743","VIOLATION_NO":"8354242","VIOLATION_ISSUE_DT":"07/22/2009","SIG_SUB":"Y","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/22/2009","PROPOSED_PENALTY":"224","AMOUNT_DUE":"157","AMOUNT_PAID":"157","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2010-188","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"1110742","VIOLATION_NO":"8354241","VIOLATION_ISSUE_DT":"07/22/2009","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/22/2009","PROPOSED_PENALTY":"224","AMOUNT_DUE":"157","AMOUNT_PAID":"157","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2010-188","sourceDate":"2009-07-22"},{"SOURCE_ROW_NUMBER":"1110741","VIOLATION_NO":"8354240","VIOLATION_ISSUE_DT":"07/17/2009","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/17/2009","PROPOSED_PENALTY":"585","AMOUNT_DUE":"497","AMOUNT_PAID":"497","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2009-1558","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1110740","VIOLATION_NO":"8354239","VIOLATION_ISSUE_DT":"07/17/2009","SIG_SUB":"N","PART_SECTION":"75.1100-2(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/17/2009","PROPOSED_PENALTY":"460","AMOUNT_DUE":"127","AMOUNT_PAID":"127","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2009-1558","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1110739","VIOLATION_NO":"8354238","VIOLATION_ISSUE_DT":"07/17/2009","SIG_SUB":"N","PART_SECTION":"75.523-3(c)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/24/2009","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1110738","VIOLATION_NO":"8354237","VIOLATION_ISSUE_DT":"07/17/2009","SIG_SUB":"N","PART_SECTION":"75.1106-3(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/17/2009","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2009-07-17"},{"SOURCE_ROW_NUMBER":"1110737","VIOLATION_NO":"8354236","VIOLATION_ISSUE_DT":"07/15/2009","SIG_SUB":"Y","PART_SECTION":"75.1909(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/15/2009","PROPOSED_PENALTY":"585","AMOUNT_DUE":"527","AMOUNT_PAID":"527","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2009-1558","sourceDate":"2009-07-15"},{"SOURCE_ROW_NUMBER":"1110736","VIOLATION_NO":"8354232","VIOLATION_ISSUE_DT":"07/14/2009","SIG_SUB":"N","PART_SECTION":"75.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/15/2009","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2009-07-14"}]}],"safety":{"href":"/api/v1/mines/1519063/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519063/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711","part":"75","subchapter":"O","subpart":"R","id":"75.1711","citation":"30 CFR 75.1711","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Mine closure; filing of map with Secretary.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1204","part":"75","subchapter":"O","subpart":"M","id":"75.1204","citation":"30 CFR 75.1204","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.364","heading":"Weekly examination.","id":"75.364","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.364","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Worked-out areas. (1) At least every 7 days, a certified person shall examine unsealed worked-out areas where no pillars have been recovered by traveling to the area of deepest penetration; measuring methane and oxygen concentrations and air quantities and making tests to determine if the air is moving in the proper direction in the area. The locations of measurement points where tests and measurements will be performed shall be included in the mine ventilation plan and shall be adequate in number and location to assure ventilation and air quality in the area. Air quantity measurements shall also be made where the air enters and leaves the worked-out area. An alternative method of evaluating the ventilation of the area may be approved in the ventilation plan.\n\n(2) At least every 7 days, a certified person shall evaluate the effectiveness of bleeder systems required by § 75.334 as follows:\n\n(i) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in its proper direction shall be made where air enters the worked-out area.\n\n(ii) Measurements of methane and oxygen concentrations and air quantity and a test to determine if the air is moving in the proper direction shall be made immediately before the air enters a return split of air.\n\n(iii) At least one entry of each set of bleeder entries used as part of a bleeder system under § 75.334 shall be traveled in its entirety. Measurements of methane and oxygen concentrations and air quantities and a test to determine if the air is moving in the proper direction shall be made at the measurement point locations specified in the mine ventilation plan to determine the effectiveness of the bleeder system.\n\n(iv) In lieu of the requirements of paragraphs (a)(2)(i) and (iii) of this section, an alternative method of evaluation may be specified in the ventilation plan provided the alternative method results in proper evaluation of the effectiveness of the bleeder system.\n\n(b) Hazardous conditions and violations of mandatory health or safety standards. At least every 7 days, an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(8) of this section shall be made by a certified person designated by the operator at the following locations:\n\n(1) In at least one entry of each intake air course, in its entirety, so that the entire air course is traveled.\n\n(2) In at least one entry of each return air course, in its entirety, so that the entire air course is traveled.\n\n(3) In each longwall or shortwall travelway in its entirety, so that the entire travelway is traveled.\n\n(4) At each seal along return and bleeder air courses and at each seal along intake air courses not examined under § 75.360(b)(5).\n\n(5) In each escapeway so that the entire escapeway is traveled.\n\n(6) On each working section not examined under § 75.360(b)(3) during the previous 7 days.\n\n(7) At each water pump not examined during a preshift examination conducted during the previous 7 days.\n\n(8) Weekly examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust; and\n\n(iv) § 75.1403—maintenance of off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) Measurements and tests. At least every 7 days, a certified person shall—\n\n(1) Determine the volume of air entering the main intakes and in each intake split;\n\n(2) Determine the volume of air and test for methane in the last open crosscut in any pair or set of developing entries or rooms, in the return of each split of air immediately before it enters the main returns, and where the air leaves the main returns; and\n\n(3) Test for methane in the return entry nearest each set of seals immediately after the air passes the seals.\n\n(d) Hazardous conditions shall be corrected immediately. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Any violation of the nine mandatory health or safety standards found during a weekly examination shall be corrected.\n\n(e) The weekly examination may be conducted at the same time as the preshift or on-shift examinations.\n\n(f) (1) The weekly examination is not required during any 7 day period in which no one enters any underground area of the mine.\n\n(2) Except for certified persons required to make examinations, no one shall enter any underground area of the mine if a weekly examination has not been completed within the previous 7 days.\n\n(g) Certification. The person making the weekly examinations shall certify by initials, date, and the time that the examination was made. Certifications and times shall appear at enough locations to show that the entire area has been examined.\n\n(h) Recordkeeping. At the completion of any shift during which a portion of a weekly examination is conducted, a record of the results of each weekly examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards found during each examination and their locations, the corrective action taken, and the results and location of air and methane measurements, shall be made. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the person making the examination or a person designated by the operator. If made by a person other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. The record shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(i) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 77 FR 20715, Apr. 6, 2012]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1106-3","heading":"Storage of liquefied and nonliquefied compressed gas cylinders; requirements.","id":"75.1106-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:\n\n(1) Clearly marked and identified as to their contents in accordance with Department of Transportation regulations.\n\n(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or otherwise secured against being accidently tipped over.\n\n(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.\n\n(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.\n\n(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.\n\n[36 FR 22061, Nov. 19, 1971]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1909","heading":"Nonpermissible diesel-powered equipment; design and performance requirements.","id":"75.1909","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-T/section-75.1909","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"T","subpartHeading":"Subpart T—Diesel-Powered Equipment","text":"(a) Nonpermissible diesel-powered equipment, except for the special category of equipment under § 75.1908(d), must be equipped with the following features:\n\n(1) An engine approved under subpart E of part 7 of this title equipped with an air filter sized in accordance with the engine manufacturer's recommendations, and an air filter service indicator set in accordance with the engine manufacturer's recommendations;\n\n(2) At least one portable multipurpose dry chemical type (ABC) fire extinguisher listed or approved by a nationally recognized independent testing laboratory with a 10A:60B:C or higher rating. The fire extinguisher must be located within easy reach of the equipment operator and protected from damage;\n\n(3) A fuel system specifically designed for diesel fuel meeting the following requirements:\n\n(i) A fuel tank and fuel lines that do not leak;\n\n(ii) A fuel tank that is substantially constructed and protected against damage by collision;\n\n(iii) A vent opening that maintains atmospheric pressure in the fuel tank, and that is designed to prevent fuel from splashing out of the vent opening;\n\n(iv) A self-closing filler cap on the fuel tank;\n\n(v) The fuel tank, filler and vent must be located so that leaks or spillage during refueling will not contact hot surfaces;\n\n(vi) Fuel line piping must be either steel-wire reinforced; synthetic elastomer-covered hose suitable for use with diesel fuel that has been tested and has been determined to be fire-resistant by the manufacturer; or metal;\n\n(vii) Fuel line piping must be clamped;\n\n(viii) Primary fuel lines must be located so that fuel line leaks do not contact hot surfaces;\n\n(ix) The fuel lines must be separated from electrical wiring and protected from damage in ordinary use;\n\n(x) A manual shutoff valve must be installed in the fuel system as close as practicable to the tank; and\n\n(xi) A water separator and fuel filter(s) must be provided.\n\n(4) A sensor to monitor the temperature and provide a visual warning of an overheated cylinder head on air-cooled engines;\n\n(5) Guarding to protect fuel, hydraulic, and electric lines when such lines pass near rotating parts or in the event of shaft failure;\n\n(6) Hydraulic tanks, fillers, vents, and lines located to prevent spillage or leaks from contacting hot surfaces;\n\n(7) Reflectors or warning lights mounted on the equipment which can be readily seen in all directions;\n\n(8) A means to direct exhaust gas away from the equipment operator, persons on board the machine, and combustible machine components;\n\n(9) A means to prevent unintentional free and uncontrolled descent of personnel-elevating work platforms; and\n\n(10) A means to prevent the spray from ruptured hydraulic or lubricating oil lines from being ignited by contact with engine exhaust system component surfaces.\n\n(b) Self-propelled nonpermissible diesel-powered equipment must have the following features in addition to those in paragraph (a):\n\n(1) A means to ensure that no stored hydraulic energy that will cause machine articulation is available after the engine is shut down;\n\n(2) A neutral start feature which ensures that engine cranking torque will not be transmitted through the powertrain and cause machine movement on vehicles utilizing fluid power transmissions;\n\n(3) For machines with steering wheels, brake pedals, and accelerator pedals, controls which are of automobile orientation;\n\n(4) An audible warning device conveniently located near the equipment operator;\n\n(5) Lights provided and maintained on both ends of the equipment. Equipment normally operated in both directions must be equipped with headlights for both directions;\n\n(6) Service brakes that act on each wheel of the vehicle and that are designed such that failure of any single component, except the brake actuation pedal or other similar actuation device, must not result in a complete loss of service braking capability;\n\n(7) Service brakes that safely bring the fully loaded vehicle to a complete stop on the maximum grade on which it is operated; and\n\n(8) No device that traps a column of fluid to hold the brake in the applied position shall be installed in any brake system, unless the trapped column of fluid is released when the equipment operator is no longer in contact with the brake activation device.\n\n(c) Self-propelled nonpermissible heavy-duty diesel-powered equipment under § 75.1908(a), except rail-mounted equipment, shall be provided with a supplemental braking system that:\n\n(1) Engages automatically within 5 seconds of the shutdown of the engine;\n\n(2) Safely brings the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(3) Holds the equipment stationary, despite any contraction of brake parts, exhaustion of any nonmechanical source of energy, or leakage;\n\n(4) Releases only by a manual control that does not operate any other equipment function;\n\n(5) Has a means in the equipment operator's compartment to apply the brakes manually without shutting down the engine, and a means to release and reengage the brakes without the engine operating; and\n\n(6) Has a means to ensure that the supplemental braking system is released before the equipment can be trammed, and is designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(d) Self-propelled nonpermissible light-duty diesel-powered equipment under § 75.1908(b), except rail-mounted equipment, must be provided with a parking brake that holds the fully loaded equipment stationary on the maximum grade on which it is operated despite any contraction of the brake parts, exhaustion of any nonmechanical source of energy, or leakage.\n\n(e) The supplemental and park brake systems required by paragraphs (c) and (d) must be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n(f) Self-propelled personnel-elevating work platforms must be provided with a means to ensure that the parking braking system is released before the equipment can be trammed, and must be designed to ensure the brake is fully released at all times while the equipment is trammed.\n\n(g) Any nonpermissible equipment that discharges its exhaust directly into a return air course must be provided with a power package approved under subpart F of part 7 of this title.\n\n(h) Self-propelled nonpermissible heavy-duty diesel-powered equipment meeting the requirements of § 75.1908(a) must be provided with an automatic fire suppression system meeting the requirements of § 75.1911.\n\n(i) Self-propelled nonpermissible light-duty diesel-powered equipment meeting the requirements of § 75.1908(b) must be provided with an automatic or manual fire suppression system meeting the requirements of § 75.1911.\n\n(j) Nonpermissible equipment that is not self-propelled must have the following features in addition to those listed in paragraph (a):\n\n(1) A means to prevent inadvertent movement of the equipment when parked;\n\n(2) Safety chains or other suitable secondary connections on equipment that is being towed; and\n\n(3) An automatic fire suppression system meeting the requirements of § 75.1911.\n\n[61 FR 55527, Oct. 25, 1996; 62 FR 34641, June 27, 1997]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.516","heading":"Power wires; support.","id":"75.516","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.516","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519063","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}