{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519055","name":"#3","status":"Abandoned and Sealed","status_date":"2007-12-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"McDowell","operator_id":"0055917","operator_name":"D & D Mining Inc","controller_id":"0046489","controller_name":"Timothy R  Dye","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.4475,"longitude":-82.698611},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":174},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519055","name":"#3"},"operator":{"type":"operator","id":"0055917","name":"D & D Mining Inc"},"controller":{"type":"controller","id":"0046489","name":"Timothy R  Dye"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041507","name":"Minerva Ruth  Mead"},"object":{"type":"mine","id":"1519055","name":"#3"},"validFrom":"2003-02-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519055|0041507|2003-02-20|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0046489","name":"Timothy R  Dye"},"object":{"type":"mine","id":"1519055","name":"#3"},"validFrom":"2004-12-16","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519055|0046489|2004-12-16|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051125","name":"MRI Mining Inc"},"object":{"type":"mine","id":"1519055","name":"#3"},"validFrom":"2006-10-25","validTo":"2007-10-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519055|0051125|2006-10-25|2007-10-22"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041507","name":"Minerva Ruth  Mead"},"object":{"type":"operator","id":"0051125","name":"MRI Mining Inc"},"validFrom":"2006-10-25","validTo":"2007-10-22","current":false,"derived":true,"evidenceMineId":"1519055","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519055|0051125|2006-10-25|0041507|2003-02-20|2689"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0055917","name":"D & D Mining Inc"},"object":{"type":"mine","id":"1519055","name":"#3"},"validFrom":"2007-10-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519055|0055917|2007-10-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0046489","name":"Timothy R  Dye"},"object":{"type":"operator","id":"0055917","name":"D & D Mining Inc"},"validFrom":"2007-10-23","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519055","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519055|0055917|2007-10-23|0046489|2004-12-16|5652"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2007-03-01","lastDate":"2007-03-01","metrics":{"daysLost":28,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"108813","DOCUMENT_NO":"220070780030","ACCIDENT_DT":"03/01/2007","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"28","NARRATIVE":"EE was pushing on freddie scoop. His chain started failing off his scoop. He started to pick his chain up when his scoop twisted around and got his finger on his left hand between scoop frame and scoop stops.","sourceDate":"2007-03-01"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-12-12","lastDate":"2007-12-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":61,"firstDate":"2006-12-20","lastDate":"2007-09-24","metrics":{"ss":30,"delinquent":61,"recentRows":0,"paidPenalty":0,"proposedPenalty":13261,"currentAssessment":13261},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1022239","VIOLATION_NO":"6651396","ISSUE_DT":"09/24/2007","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"1022238","VIOLATION_NO":"6651395","ISSUE_DT":"09/20/2007","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-20"},{"SOURCE_ROW_NUMBER":"1022237","VIOLATION_NO":"6651384","ISSUE_DT":"09/17/2007","CFR_STANDARD_CD":"75.508","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-17"},{"SOURCE_ROW_NUMBER":"1022236","VIOLATION_NO":"6651380","ISSUE_DT":"09/10/2007","CFR_STANDARD_CD":"77.904","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1022234","VIOLATION_NO":"6650959","ISSUE_DT":"09/10/2007","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1022233","VIOLATION_NO":"6650958","ISSUE_DT":"09/10/2007","CFR_STANDARD_CD":"77.205(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"334.00","CURRENT_ASSESSMENT_AMT":"334.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1022232","VIOLATION_NO":"6650957","ISSUE_DT":"09/10/2007","CFR_STANDARD_CD":"75.1725(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"634.00","CURRENT_ASSESSMENT_AMT":"634.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1022231","VIOLATION_NO":"6650956","ISSUE_DT":"09/10/2007","CFR_STANDARD_CD":"75.310(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1022230","VIOLATION_NO":"6650955","ISSUE_DT":"09/10/2007","CFR_STANDARD_CD":"77.207","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"150.00","CURRENT_ASSESSMENT_AMT":"150.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1022229","VIOLATION_NO":"6650942","ISSUE_DT":"08/22/2007","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"1022228","VIOLATION_NO":"6650941","ISSUE_DT":"08/22/2007","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"176.00","CURRENT_ASSESSMENT_AMT":"176.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"1022227","VIOLATION_NO":"6650940","ISSUE_DT":"08/22/2007","CFR_STANDARD_CD":"75.1712-6(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-08-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":22,"firstDate":"2007-03-21","lastDate":"2007-09-24","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":22,"maxConcentration":2.929,"concentrationTotal":22.817},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1459572","CASS_NUM":"57648207","SMP_TAKEN_DT":"9/24/2007","CONC":".135","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"1033303","CASS_NUM":"57648206","SMP_TAKEN_DT":"9/24/2007","CONC":".967","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"608591","CASS_NUM":"57648179","SMP_TAKEN_DT":"9/24/2007","CONC":"1.049","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"491769","CASS_NUM":"57648177","SMP_TAKEN_DT":"9/24/2007","CONC":".83","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"259971","CASS_NUM":"57648232","SMP_TAKEN_DT":"9/24/2007","CONC":".556","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"13893","CASS_NUM":"57648172","SMP_TAKEN_DT":"9/24/2007","CONC":".142","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"1610223","CASS_NUM":"57713354","SMP_TAKEN_DT":"6/27/2007","CONC":".51","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"979934","CASS_NUM":"57713350","SMP_TAKEN_DT":"6/27/2007","CONC":"1.046","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"302576","CASS_NUM":"57713333","SMP_TAKEN_DT":"6/27/2007","CONC":".237","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"44803","CASS_NUM":"57713347","SMP_TAKEN_DT":"6/27/2007","CONC":".599","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"39428","CASS_NUM":"57703345","SMP_TAKEN_DT":"6/27/2007","CONC":"1.058","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"1115490","CASS_NUM":"50885881","SMP_TAKEN_DT":"6/1/2007","CONC":".751","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-01"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2006-10-25","lastDate":"2007-10-23","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":9,"firstDate":"2006-10-30","lastDate":"2007-11-26","metrics":{"inspectors":14,"recentRows":0,"onSiteHours":163.25,"inspectionHours":265.5,"inspectionSamples":43},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"20828","EVENT_NO":"4190807","INSPECTION_BEGIN_DT":"11/26/2007","INSPECTION_END_DT":"11/26/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2007-11-26"},{"SOURCE_ROW_NUMBER":"655400","EVENT_NO":"4190279","INSPECTION_BEGIN_DT":"07/11/2007","INSPECTION_END_DT":"09/30/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"94","SUM_TOTAL_ON_SITE_HOURS":"63","sourceDate":"2007-07-11"},{"SOURCE_ROW_NUMBER":"295876","EVENT_NO":"4190182","INSPECTION_BEGIN_DT":"06/21/2007","INSPECTION_END_DT":"06/28/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"61.5","SUM_TOTAL_ON_SITE_HOURS":"40","sourceDate":"2007-06-21"},{"SOURCE_ROW_NUMBER":"992362","EVENT_NO":"4190509","INSPECTION_BEGIN_DT":"04/05/2007","INSPECTION_END_DT":"04/05/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2007-04-05"},{"SOURCE_ROW_NUMBER":"552036","EVENT_NO":"4194232","INSPECTION_BEGIN_DT":"03/15/2007","INSPECTION_END_DT":"03/15/2007","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2007-03-15"},{"SOURCE_ROW_NUMBER":"387537","EVENT_NO":"4189548","INSPECTION_BEGIN_DT":"01/22/2007","INSPECTION_END_DT":"03/22/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"44.5","SUM_TOTAL_ON_SITE_HOURS":"26.5","sourceDate":"2007-01-22"},{"SOURCE_ROW_NUMBER":"59396","EVENT_NO":"4189348","INSPECTION_BEGIN_DT":"12/11/2006","INSPECTION_END_DT":"12/26/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"18.5","SUM_TOTAL_ON_SITE_HOURS":"9.75","sourceDate":"2006-12-11"},{"SOURCE_ROW_NUMBER":"400900","EVENT_NO":"4227207","INSPECTION_BEGIN_DT":"11/08/2006","INSPECTION_END_DT":"11/13/2006","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2006-11-08"},{"SOURCE_ROW_NUMBER":"1110411","EVENT_NO":"4192847","INSPECTION_BEGIN_DT":"10/30/2006","INSPECTION_END_DT":"10/30/2006","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2006-10-30"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q4":{"hours":120,"employees":3,"production":0},"2007-Q2":{"hours":6116,"employees":13,"production":12254},"2007-Q1":{"hours":5019,"employees":11,"production":15242}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":11255,"employees":9,"production":27496}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":5,"firstDate":"2007-09-24","lastDate":"2007-09-24","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":169,"pelDoseTotal":101},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94271","EVENT_NO":"4190279","SURVEY_DATE":"09/24/2007","OCCUPATION_CD_DESC":"BLASTER/SHOOTER/SHOTFIRER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"6","PEL_DOSE_90":"4","SURVEY_TYPE":"I","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"94270","EVENT_NO":"4190279","SURVEY_DATE":"09/24/2007","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"46","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"94269","EVENT_NO":"4190279","SURVEY_DATE":"09/24/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"44","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"94268","EVENT_NO":"4190279","SURVEY_DATE":"09/24/2007","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"100","ACT_DOSE_85":"9","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"94267","EVENT_NO":"4190279","SURVEY_DATE":"09/24/2007","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"64","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2007-09-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":2,"firstDate":"2007-03-21","lastDate":"2007-09-24","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":6.1,"validSamples":2,"quartzPctTotal":12.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"158674","CASSETTE_NO":"57648177","SAMPLE_DT":"09/24/2007","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"138283","CASSETTE_NO":"57703329","SAMPLE_DT":"03/21/2007","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":62,"firstDate":"2006-12-20","lastDate":"2007-09-24","metrics":{"ss":30,"amountDue":13261,"contested":0,"amountPaid":0,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":13261},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1110106","VIOLATION_NO":"6651396","VIOLATION_ISSUE_DT":"09/24/2007","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/24/2007","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-24"},{"SOURCE_ROW_NUMBER":"1110105","VIOLATION_NO":"6651395","VIOLATION_ISSUE_DT":"09/20/2007","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/24/2007","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-20"},{"SOURCE_ROW_NUMBER":"1110104","VIOLATION_NO":"6651384","VIOLATION_ISSUE_DT":"09/17/2007","SIG_SUB":"N","PART_SECTION":"75.508","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/20/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-17"},{"SOURCE_ROW_NUMBER":"1110103","VIOLATION_NO":"6651381","VIOLATION_ISSUE_DT":"09/10/2007","PART_SECTION":"75.1403-7(e)","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"09/10/2007","CONTESTED_IND":"N","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1110102","VIOLATION_NO":"6651380","VIOLATION_ISSUE_DT":"09/10/2007","SIG_SUB":"Y","PART_SECTION":"77.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/10/2007","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1110100","VIOLATION_NO":"6650959","VIOLATION_ISSUE_DT":"09/10/2007","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/10/2007","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1110099","VIOLATION_NO":"6650958","VIOLATION_ISSUE_DT":"09/10/2007","SIG_SUB":"Y","PART_SECTION":"77.205(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2007","PROPOSED_PENALTY":"334","AMOUNT_DUE":"334","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1110098","VIOLATION_NO":"6650957","VIOLATION_ISSUE_DT":"09/10/2007","SIG_SUB":"Y","PART_SECTION":"75.1725(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2007","PROPOSED_PENALTY":"634","AMOUNT_DUE":"634","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1110097","VIOLATION_NO":"6650956","VIOLATION_ISSUE_DT":"09/10/2007","SIG_SUB":"N","PART_SECTION":"75.310(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2007","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1110096","VIOLATION_NO":"6650955","VIOLATION_ISSUE_DT":"09/10/2007","SIG_SUB":"N","PART_SECTION":"77.207","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2007","PROPOSED_PENALTY":"150","AMOUNT_DUE":"150","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-09-10"},{"SOURCE_ROW_NUMBER":"1110095","VIOLATION_NO":"6650942","VIOLATION_ISSUE_DT":"08/22/2007","SIG_SUB":"Y","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/22/2007","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"1110094","VIOLATION_NO":"6650941","VIOLATION_ISSUE_DT":"08/22/2007","SIG_SUB":"Y","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/22/2007","PROPOSED_PENALTY":"176","AMOUNT_DUE":"176","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-08-22"}]}],"safety":{"href":"/api/v1/mines/1519055/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519055/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.508","heading":"Map of electrical system.","id":"75.508","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.508","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe location and the electrical rating of all stationary electric apparatus in connection with the mine electric system, including permanent cables, switchgear, rectifying substations, transformers, permanent pumps, and trolley wires and trolley feeder wires, and settings of all direct-current circuit breakers protecting underground trolley circuits, shall be shown on a mine map. Any changes made in a location, electric rating, or setting shall be promptly shown on the map when the change is made. Such map shall be available to an authorized representative of the Secretary and to the miners in such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403-7","heading":"Criteria—Mantrips.","id":"75.1403-7","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403-7","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"(a) Mantrips should be operated independently of any loaded trip, empty trip, or supply trip and should not be operated within 300 feet of any trip, including another mantrip.\n\n(b) A sufficient number of mantrip cars should be provided to prevent overcrowding of men.\n\n(c) Mantrips should not be pushed.\n\n(d) Where mantrips are operated by locomotives on slopes such mantrips should be coupled to the front and rear by locomotives capable of holding such mantrips. Where ropes are used on slopes for mantrip haulage, such conveyances should be connected by chains, steel ropes, or other effective devices between mantrip cars and the rope.\n\n(e) Safety goggles or eyeshields should be provided for all persons being transported in open-type mantrips.\n\n(f) All trips, including trailers and sleds, should be operated at speeds consistent with conditions and the equipment used, and should be so controlled that they can be stopped within the limits of visibility.\n\n(g) All mantrips should be under the direction of a supervisor and the operator of each mantrip should be familiar with the haulage safety rules and regulations.\n\n(h) Men should proceed in an orderly manner to and from mantrips and no person should be permitted to get on or off a moving mantrip.\n\n(i) [Reserved]\n\n(j) Mantrips should not be permitted to proceed until the operator of the mantrip is assured that he has a clear road.\n\n(k) Supplies or tools, except small hand tools or instruments, should not be transported with men.\n\n(l) At places where men enter or leave mantrip conveyances, ample clearance should be provided and provisions made to prevent persons from coming in contact with energized electric circuits.\n\n(m) The mine car next to a trolley locomotive should not be used to transport men. Such cars may be used to transport small tools and supplies. This is not to be construed as permitting the transportation of large or bulky supplies such as shuttle car wheel units, or similar material.\n\n(n) Drop-bottom cars used to transport men should have the bottoms secured with an additional locking device.\n\n(o) Extraneous materials or supplies should not be transported on top of equipment; however, materials and supplies that are necessary for or related to the operation of such equipment may be transported on top of such equipment if a hazard is not introduced.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 53 FR 46786, Nov. 18, 1988]","occurrenceCount":1},{"chapter":"I","heading":"Identification of circuit breakers.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-J/section-77.904","part":"77","subchapter":"O","subpart":"J","id":"77.904","citation":"30 CFR 77.904","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1725","heading":"Machinery and equipment; operation and maintenance.","id":"75.1725","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1725","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Installation of main mine fans.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.310","part":"75","subchapter":"O","subpart":"D","id":"75.310","citation":"30 CFR 75.310","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Illumination.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.207","part":"77","subchapter":"O","subpart":"C","id":"77.207","citation":"30 CFR 77.207","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519055","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}