{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519045","name":"No. 2","status":"Abandoned","status_date":"2009-04-14","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Pikeville","operator_id":"0072063","operator_name":"C & N Mining LLC","controller_id":"0060349","controller_name":"Chris  Patton; Nicki  Patton","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.492777,"longitude":-82.445833},"coverage":{"contributingSources":11,"registeredSources":20,"sourceRows":209},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519045","name":"No. 2"},"operator":{"type":"operator","id":"0072063","name":"C & N Mining LLC"},"controller":{"type":"controller","id":"0060349","name":"Chris  Patton; Nicki  Patton"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14959","name":"Connie  Bryant"},"object":{"type":"mine","id":"1519045","name":"No. 2"},"validFrom":"2003-06-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519045|C14959|2003-06-17|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0060349","name":"Chris  Patton  et al"},"object":{"type":"mine","id":"1519045","name":"No. 2"},"validFrom":"2006-05-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519045|0060349|2006-05-08|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051435","name":"Foggy Mountain Coal Co. Inc."},"object":{"type":"mine","id":"1519045","name":"No. 2"},"validFrom":"2006-09-08","validTo":"2008-01-09","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519045|0051435|2006-09-08|2008-01-09"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14959","name":"Connie  Bryant"},"object":{"type":"operator","id":"0051435","name":"Foggy Mountain Coal Co. Inc."},"validFrom":"2006-09-08","validTo":"2008-01-09","current":false,"derived":true,"evidenceMineId":"1519045","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519045|0051435|2006-09-08|C14959|2003-06-17|94346"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0072063","name":"C & N Mining LLC"},"object":{"type":"mine","id":"1519045","name":"No. 2"},"validFrom":"2008-01-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519045|0072063|2008-01-10|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0060349","name":"Chris  Patton  et al"},"object":{"type":"operator","id":"0072063","name":"C & N Mining LLC"},"validFrom":"2008-01-10","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519045","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519045|0072063|2008-01-10|0060349|2006-05-08|8045"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0060349","name":"Nicki  Patton  et al"},"object":{"type":"operator","id":"0072063","name":"C & N Mining LLC"},"validFrom":"2008-01-10","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519045","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519045|0072063|2008-01-10|0060349|2006-05-08|8046"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2008-10-21","lastDate":"2008-10-21","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"125982","DOCUMENT_NO":"220090560039","ACCIDENT_DT":"10/21/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was bolting top when piece of draw rock fell and smashed right hand.","sourceDate":"2008-10-21"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-04-14","lastDate":"2009-04-14","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":58,"firstDate":"2006-11-09","lastDate":"2009-02-03","metrics":{"ss":23,"delinquent":58,"recentRows":0,"paidPenalty":1956,"proposedPenalty":15256,"currentAssessment":15256},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"973336","VIOLATION_NO":"7421405","ISSUE_DT":"02/03/2009","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-03"},{"SOURCE_ROW_NUMBER":"973328","VIOLATION_NO":"7421403","ISSUE_DT":"12/03/2008","CFR_STANDARD_CD":"75.203(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"973327","VIOLATION_NO":"7421402","ISSUE_DT":"12/03/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"973335","VIOLATION_NO":"7445173","ISSUE_DT":"11/20/2008","CFR_STANDARD_CD":"75.1103-4(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-20"},{"SOURCE_ROW_NUMBER":"973334","VIOLATION_NO":"7445172","ISSUE_DT":"11/20/2008","CFR_STANDARD_CD":"75.601-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-20"},{"SOURCE_ROW_NUMBER":"973326","VIOLATION_NO":"7421399","ISSUE_DT":"11/20/2008","CFR_STANDARD_CD":"75.1106-2(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-20"},{"SOURCE_ROW_NUMBER":"973333","VIOLATION_NO":"7445170","ISSUE_DT":"11/18/2008","CFR_STANDARD_CD":"77.506-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-18"},{"SOURCE_ROW_NUMBER":"973332","VIOLATION_NO":"7445169","ISSUE_DT":"11/18/2008","CFR_STANDARD_CD":"77.506-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-18"},{"SOURCE_ROW_NUMBER":"973331","VIOLATION_NO":"7445168","ISSUE_DT":"11/17/2008","CFR_STANDARD_CD":"75.1107-4(a)(2)(ii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-17"},{"SOURCE_ROW_NUMBER":"973330","VIOLATION_NO":"7445167","ISSUE_DT":"11/17/2008","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-17"},{"SOURCE_ROW_NUMBER":"973329","VIOLATION_NO":"7445166","ISSUE_DT":"11/13/2008","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-13"},{"SOURCE_ROW_NUMBER":"973325","VIOLATION_NO":"7421395","ISSUE_DT":"11/13/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-11-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":26,"firstDate":"2006-12-20","lastDate":"2008-11-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":5,"validSamples":21,"maxConcentration":0.974,"concentrationTotal":9.878},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1570658","CASS_NUM":"50989542","SMP_TAKEN_DT":"11/25/2008","CONC":".07","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-25"},{"SOURCE_ROW_NUMBER":"99316","CASS_NUM":"50989525","SMP_TAKEN_DT":"11/24/2008","CONC":".258","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-24"},{"SOURCE_ROW_NUMBER":"30378","CASS_NUM":"50982396","SMP_TAKEN_DT":"11/14/2008","CONC":".974","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-14"},{"SOURCE_ROW_NUMBER":"1561658","CASS_NUM":"50982404","SMP_TAKEN_DT":"11/13/2008","CONC":".521","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-13"},{"SOURCE_ROW_NUMBER":"200391","CASS_NUM":"50982399","SMP_TAKEN_DT":"11/12/2008","CONC":".53","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-12"},{"SOURCE_ROW_NUMBER":"883565","CASS_NUM":"50982415","SMP_TAKEN_DT":"11/10/2008","CONC":".309","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-10"},{"SOURCE_ROW_NUMBER":"642379","CASS_NUM":"50982398","SMP_TAKEN_DT":"11/10/2008","CONC":".286","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-11-10"},{"SOURCE_ROW_NUMBER":"988190","CASS_NUM":"50926805","SMP_TAKEN_DT":"11/28/2007","CONC":".774","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID SAMPLE TYPE","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-11-28"},{"SOURCE_ROW_NUMBER":"52154","CASS_NUM":"50926766","SMP_TAKEN_DT":"11/27/2007","CONC":".539","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-11-27"},{"SOURCE_ROW_NUMBER":"606877","CASS_NUM":"50926832","SMP_TAKEN_DT":"11/26/2007","CONC":".327","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT YET USED IN DETERMINATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-11-26"},{"SOURCE_ROW_NUMBER":"1041845","CASS_NUM":"57680428","SMP_TAKEN_DT":"10/9/2007","CONC":".34","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-10-09"},{"SOURCE_ROW_NUMBER":"700135","CASS_NUM":"57680461","SMP_TAKEN_DT":"10/9/2007","CONC":".286","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-10-09"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":5,"firstDate":"2007-11-01","lastDate":"2007-12-13","metrics":{"linkedIssuances":5},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2006-09-08","lastDate":"2008-01-10","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":21,"firstDate":"2006-10-11","lastDate":"2009-12-21","metrics":{"inspectors":29,"recentRows":0,"onSiteHours":257,"inspectionHours":470.25,"inspectionSamples":33},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"416166","EVENT_NO":"4173909","INSPECTION_BEGIN_DT":"12/21/2009","INSPECTION_END_DT":"12/21/2009","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2009-12-21"},{"SOURCE_ROW_NUMBER":"998114","EVENT_NO":"4173730","INSPECTION_BEGIN_DT":"04/17/2009","INSPECTION_END_DT":"04/17/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2009-04-17"},{"SOURCE_ROW_NUMBER":"617978","EVENT_NO":"4173725","INSPECTION_BEGIN_DT":"02/02/2009","INSPECTION_END_DT":"02/23/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"21","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"927330","EVENT_NO":"4177100","INSPECTION_BEGIN_DT":"12/15/2008","INSPECTION_END_DT":"01/27/2009","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2008-12-15"},{"SOURCE_ROW_NUMBER":"1035372","EVENT_NO":"4196452","INSPECTION_BEGIN_DT":"12/08/2008","INSPECTION_END_DT":"12/08/2008","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2008-12-08"},{"SOURCE_ROW_NUMBER":"488691","EVENT_NO":"4173723","INSPECTION_BEGIN_DT":"11/12/2008","INSPECTION_END_DT":"12/08/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"88.25","SUM_TOTAL_ON_SITE_HOURS":"47.25","sourceDate":"2008-11-12"},{"SOURCE_ROW_NUMBER":"332774","EVENT_NO":"4196157","INSPECTION_BEGIN_DT":"10/01/2008","INSPECTION_END_DT":"10/01/2008","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2008-10-01"},{"SOURCE_ROW_NUMBER":"98598","EVENT_NO":"4173810","INSPECTION_BEGIN_DT":"08/19/2008","INSPECTION_END_DT":"09/10/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2008-08-19"},{"SOURCE_ROW_NUMBER":"302795","EVENT_NO":"4173617","INSPECTION_BEGIN_DT":"08/11/2008","INSPECTION_END_DT":"08/15/2008","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.75","SUM_TOTAL_ON_SITE_HOURS":"1.25","sourceDate":"2008-08-11"},{"SOURCE_ROW_NUMBER":"374559","EVENT_NO":"4173432","INSPECTION_BEGIN_DT":"01/09/2008","INSPECTION_END_DT":"01/14/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2008-01-09"},{"SOURCE_ROW_NUMBER":"929323","EVENT_NO":"4173424","INSPECTION_BEGIN_DT":"10/01/2007","INSPECTION_END_DT":"12/19/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"114.75","SUM_TOTAL_ON_SITE_HOURS":"70.75","sourceDate":"2007-10-01"},{"SOURCE_ROW_NUMBER":"568538","EVENT_NO":"4194631","INSPECTION_BEGIN_DT":"09/19/2007","INSPECTION_END_DT":"09/19/2007","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2007-09-19"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":25,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009-Q2":{"hours":0,"employees":0,"production":0},"2009-Q1":{"hours":0,"employees":0,"production":0},"2008-Q4":{"hours":10673,"employees":24,"production":17928},"2008-Q3":{"hours":1459,"employees":9,"production":1116},"2008-Q1":{"hours":0,"employees":0,"production":0},"2007-Q4":{"hours":1574,"employees":8,"production":7268},"2007-Q3":{"hours":240,"employees":2,"production":2429},"2007-Q2":{"hours":374,"employees":2,"production":0},"2007-Q1":{"hours":537,"employees":2,"production":0},"2006-Q4":{"hours":530,"employees":2,"production":0},"2006-Q3":{"hours":565,"employees":2,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":1095,"employees":2,"production":0},"2007":{"hours":2725,"employees":6,"production":9697},"2008":{"hours":12132,"employees":19,"production":19044}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":62,"firstDate":"2006-11-09","lastDate":"2009-02-03","metrics":{"ss":23,"amountDue":15256,"contested":0,"amountPaid":1956,"recentRows":0,"section104d":2,"unterminated":0,"proposedPenalty":15256},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1109102","VIOLATION_NO":"7421405","VIOLATION_ISSUE_DT":"02/03/2009","SIG_SUB":"N","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/19/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2009-02-03"},{"SOURCE_ROW_NUMBER":"1109153","VIOLATION_NO":"7421403","VIOLATION_ISSUE_DT":"12/03/2008","SIG_SUB":"N","PART_SECTION":"75.203(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/03/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"1109152","VIOLATION_NO":"7421402","VIOLATION_ISSUE_DT":"12/03/2008","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"12/03/2008","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"585","CONTESTED_IND":"N","sourceDate":"2008-12-03"},{"SOURCE_ROW_NUMBER":"1109160","VIOLATION_NO":"7445173","VIOLATION_ISSUE_DT":"11/20/2008","SIG_SUB":"N","PART_SECTION":"75.1103-4(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/24/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-20"},{"SOURCE_ROW_NUMBER":"1109159","VIOLATION_NO":"7445172","VIOLATION_ISSUE_DT":"11/20/2008","SIG_SUB":"N","PART_SECTION":"75.601-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/20/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-20"},{"SOURCE_ROW_NUMBER":"1109151","VIOLATION_NO":"7421399","VIOLATION_ISSUE_DT":"11/20/2008","SIG_SUB":"N","PART_SECTION":"75.1106-2(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"6","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/20/2008","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"108","CONTESTED_IND":"N","sourceDate":"2008-11-20"},{"SOURCE_ROW_NUMBER":"1109150","VIOLATION_NO":"7421398","VIOLATION_ISSUE_DT":"11/20/2008","PART_SECTION":"75.1403","CIT_ORD_SAFE":"Safeguard","NO_AFFECTED":"0","TERMINATION_DT":"11/24/2008","CONTESTED_IND":"N","sourceDate":"2008-11-20"},{"SOURCE_ROW_NUMBER":"1109158","VIOLATION_NO":"7445170","VIOLATION_ISSUE_DT":"11/18/2008","SIG_SUB":"N","PART_SECTION":"77.506-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/20/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-18"},{"SOURCE_ROW_NUMBER":"1109157","VIOLATION_NO":"7445169","VIOLATION_ISSUE_DT":"11/18/2008","SIG_SUB":"N","PART_SECTION":"77.506-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/20/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-18"},{"SOURCE_ROW_NUMBER":"1109156","VIOLATION_NO":"7445168","VIOLATION_ISSUE_DT":"11/17/2008","SIG_SUB":"N","PART_SECTION":"75.1107-4(a)(2)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/17/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-17"},{"SOURCE_ROW_NUMBER":"1109155","VIOLATION_NO":"7445167","VIOLATION_ISSUE_DT":"11/17/2008","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/17/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-17"},{"SOURCE_ROW_NUMBER":"1109154","VIOLATION_NO":"7445166","VIOLATION_ISSUE_DT":"11/13/2008","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/17/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2008-11-13"}]}],"safety":{"href":"/api/v1/mines/1519045/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519045/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":2},{"chapter":"I","heading":"Mining methods.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.203","part":"75","subchapter":"O","subpart":"C","id":"75.203","citation":"30 CFR 75.203","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-4","heading":"Automatic fire sensor and warning device systems; installation; minimum requirements.","id":"75.1103-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Effective December 31, 2009, automatic fire sensor and warning device systems that use carbon monoxide sensors shall provide identification of fire along all belt conveyors.\n\n(1) Carbon monoxide sensors shall be installed at the following locations:\n\n(i) Not more than 100 feet downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the distance between the units is less than 100 feet, they may be monitored with one sensor downwind of the last component. If the distance between the units exceeds 100 feet, additional sensors are required downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up;\n\n(ii) Not more than 100 feet downwind of each section loading point;\n\n(iii) Along the belt entry so that the spacing between sensors does not exceed 1,000 feet. Where air velocities are less than 50 feet per minute, spacing must not exceed 350 feet; and\n\n(iv) The mine operator shall indicate the locations of all carbon monoxide sensors on the mine maps required by §§ 75.1200 and 75.1505 of this part.\n\n(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to carbon monoxide sensors, and installed within the time specified in paragraph (a)(3) of this section.\n\n(3) When the distance from the tailpiece at loading points to the first outby sensor reaches the spacing requirements in § 75.1103-4(a)(1)(iii), an additional sensor shall be installed and put in operation within 24 production shift hours. When sensors of the kind described in paragraph (a)(2) of this section are used, they shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.\n\n(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load. Sensors must be installed near the center in the upper third of the entry, in a manner that does not expose personnel working on the system to unsafe conditions. Sensors must not be located in abnormally high areas or in other locations where air flow patterns do not permit products of combustion to be carried to the sensors.\n\n(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.\n\n(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.\n\n(e) Except when power must be cut off in the mine under the provisions of § 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e) (1) or (2) of this section.\n\n(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.\n\n(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 57 FR 20928, May 15, 1992; 73 FR 80614, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.601-1","heading":"Short circuit protection; ratings and settings of circuit breakers.","id":"75.601-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.601-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:\n\nConductor size AWG or MGM Maximum allowable circuit breaker instantaneous setting (amperes) 14 50 12 75 10 150 8 200 6 300 4 500 3 600 2 800 1 1,000 1/0 1,250 2/0 1,500 3/0 2,000 4/0 2,500 250 2,500 300 2,500 350 2,500 400 2,500 450 2,500 500 2,500","occurrenceCount":1},{"chapter":"I","heading":"Transportation of liquefied and nonliquefied compressed gas cylinders; requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1106-2","part":"75","subchapter":"O","subpart":"L","id":"75.1106-2","citation":"30 CFR 75.1106-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1403","heading":"Other safeguards.","id":"75.1403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-O/section-75.1403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"O","subpartHeading":"Subpart O—Hoisting and Mantrips","text":"[Statutory Provisions]\n\nOther safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.","occurrenceCount":1},{"chapter":"I","heading":"Electric equipment and circuits; overload and short circuit protection; minimum requirements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.506-1","part":"77","subchapter":"O","subpart":"F","id":"77.506-1","citation":"30 CFR 77.506-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-4","heading":"Automatic fire sensors and manual actuators; installation; minimum requirements.","id":"75.1107-4","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-4","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprinklers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprinklers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.\n\n(2) Two or more manual actuators, where practicable, shall be installed, as provided in paragraphs (a)(2) (i) and (ii) of this section, to activate fire suppression devices on attended equipment purchased on or after the effective date of this § 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this § 75.1107-4.\n\n(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in § 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.\n\n(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in § 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.\n\n(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A-1967).\n\n(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.\n\n(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.\n\n(e) Sensor systems shall include a device or method for determining their operative condition.\n\n[37 FR 15301, July 29, 1972]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519045","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}