{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519042","name":"#1","status":"Abandoned","status_date":"2008-06-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Knott","nearest_town":"Kite","operator_id":"0082364","operator_name":"Viper Coal, LLC","controller_id":"0069491","controller_name":"Jody Dale Puckett","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.319444,"longitude":-82.773333},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":501},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519042","name":"#1"},"operator":{"type":"operator","id":"0082364","name":"Viper Coal, LLC"},"controller":{"type":"controller","id":"0069491","name":"Jody Dale Puckett"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15865","name":"Donna L  Johnson"},"object":{"type":"mine","id":"1519042","name":"#1"},"validFrom":"2003-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519042|C15865|2003-01-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050920","name":"Pride Mining Inc"},"object":{"type":"mine","id":"1519042","name":"#1"},"validFrom":"2006-09-01","validTo":"2007-07-24","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519042|0050920|2006-09-01|2007-07-24"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15865","name":"Donna L  Johnson"},"object":{"type":"operator","id":"0050920","name":"Pride Mining Inc"},"validFrom":"2006-09-01","validTo":"2007-07-24","current":false,"derived":true,"evidenceMineId":"1519042","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519042|0050920|2006-09-01|C15865|2003-01-01|97344"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0082364","name":"Viper Coal, LLC"},"object":{"type":"mine","id":"1519042","name":"#1"},"validFrom":"2007-07-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519042|0082364|2007-07-25|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0069491","name":"Jody Dale Puckett"},"object":{"type":"mine","id":"1519042","name":"#1"},"validFrom":"2007-07-25","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519042|0069491|2007-07-25|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0069491","name":"Jody Dale Puckett"},"object":{"type":"operator","id":"0082364","name":"Viper Coal, LLC"},"validFrom":"2007-07-25","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519042","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519042|0082364|2007-07-25|0069491|2007-07-25|9855"}}],"coverage":{"historyRecords":2,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2008-06-25","lastDate":"2008-06-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":167,"firstDate":"2006-10-25","lastDate":"2008-05-08","metrics":{"ss":75,"delinquent":167,"recentRows":0,"paidPenalty":3926.8,"proposedPenalty":254016,"currentAssessment":254016},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"997363","VIOLATION_NO":"6658960","ISSUE_DT":"05/08/2008","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-05-08"},{"SOURCE_ROW_NUMBER":"1042847","VIOLATION_NO":"6655333","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"60000.00","CURRENT_ASSESSMENT_AMT":"60000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997362","VIOLATION_NO":"6657672","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997361","VIOLATION_NO":"6657671","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997360","VIOLATION_NO":"6657670","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.1714-3(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"207.00","CURRENT_ASSESSMENT_AMT":"207.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997359","VIOLATION_NO":"6657669","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997358","VIOLATION_NO":"6657668","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.807","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997357","VIOLATION_NO":"6657667","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.1505(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"460.00","CURRENT_ASSESSMENT_AMT":"460.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997356","VIOLATION_NO":"6657666","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997355","VIOLATION_NO":"6657665","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997354","VIOLATION_NO":"6657664","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"285.00","CURRENT_ASSESSMENT_AMT":"285.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"997353","VIOLATION_NO":"6657663","ISSUE_DT":"04/30/2008","CFR_STANDARD_CD":"75.1101-11","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2008-04-30"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":88,"firstDate":"2006-10-26","lastDate":"2008-04-23","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":17,"validSamples":71,"maxConcentration":7.144,"concentrationTotal":55.366},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1565639","CASS_NUM":"57691900","SMP_TAKEN_DT":"4/23/2008","CONC":".149","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-23"},{"SOURCE_ROW_NUMBER":"780099","CASS_NUM":"57691887","SMP_TAKEN_DT":"4/23/2008","CONC":".163","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-23"},{"SOURCE_ROW_NUMBER":"753396","CASS_NUM":"57691909","SMP_TAKEN_DT":"4/23/2008","CONC":".733","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-23"},{"SOURCE_ROW_NUMBER":"629332","CASS_NUM":"57691901","SMP_TAKEN_DT":"4/23/2008","CONC":".411","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-23"},{"SOURCE_ROW_NUMBER":"544538","CASS_NUM":"57691903","SMP_TAKEN_DT":"4/23/2008","CONC":".094","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-23"},{"SOURCE_ROW_NUMBER":"336032","CASS_NUM":"57691890","SMP_TAKEN_DT":"4/23/2008","CONC":".322","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER HELPER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-23"},{"SOURCE_ROW_NUMBER":"259717","CASS_NUM":"57691906","SMP_TAKEN_DT":"4/23/2008","CONC":".37","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-23"},{"SOURCE_ROW_NUMBER":"1442727","CASS_NUM":"50955198","SMP_TAKEN_DT":"4/4/2008","CONC":".452","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-04"},{"SOURCE_ROW_NUMBER":"1349396","CASS_NUM":"50955199","SMP_TAKEN_DT":"4/4/2008","CONC":".38","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-04"},{"SOURCE_ROW_NUMBER":"1153883","CASS_NUM":"50955161","SMP_TAKEN_DT":"4/4/2008","CONC":".396","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-04"},{"SOURCE_ROW_NUMBER":"852640","CASS_NUM":"50955167","SMP_TAKEN_DT":"4/3/2008","CONC":".649","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-03"},{"SOURCE_ROW_NUMBER":"1453917","CASS_NUM":"50955168","SMP_TAKEN_DT":"4/2/2008","CONC":".061","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2008-04-02"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":19,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2006-09-01","lastDate":"2007-07-25","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":15,"firstDate":"2006-09-25","lastDate":"2008-04-25","metrics":{"inspectors":38,"recentRows":0,"onSiteHours":513.25,"inspectionHours":894.25,"inspectionSamples":95},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"985058","EVENT_NO":"4182375","INSPECTION_BEGIN_DT":"04/25/2008","INSPECTION_END_DT":"06/30/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"84.5","SUM_TOTAL_ON_SITE_HOURS":"44.5","sourceDate":"2008-04-25"},{"SOURCE_ROW_NUMBER":"41207","EVENT_NO":"4195061","INSPECTION_BEGIN_DT":"04/25/2008","INSPECTION_END_DT":"05/01/2008","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"85","SUM_TOTAL_ON_SITE_HOURS":"32.5","sourceDate":"2008-04-25"},{"SOURCE_ROW_NUMBER":"823139","EVENT_NO":"4182291","INSPECTION_BEGIN_DT":"04/03/2008","INSPECTION_END_DT":"06/30/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"88.5","SUM_TOTAL_ON_SITE_HOURS":"53.75","sourceDate":"2008-04-03"},{"SOURCE_ROW_NUMBER":"61029","EVENT_NO":"4182465","INSPECTION_BEGIN_DT":"01/02/2008","INSPECTION_END_DT":"03/31/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"186","SUM_TOTAL_ON_SITE_HOURS":"112.75","sourceDate":"2008-01-02"},{"SOURCE_ROW_NUMBER":"800801","EVENT_NO":"4182601","INSPECTION_BEGIN_DT":"11/20/2007","INSPECTION_END_DT":"11/27/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"26.5","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2007-11-20"},{"SOURCE_ROW_NUMBER":"369784","EVENT_NO":"4182281","INSPECTION_BEGIN_DT":"10/03/2007","INSPECTION_END_DT":"11/08/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"82.5","SUM_TOTAL_ON_SITE_HOURS":"53.75","sourceDate":"2007-10-03"},{"SOURCE_ROW_NUMBER":"954159","EVENT_NO":"4438201","INSPECTION_BEGIN_DT":"07/02/2007","INSPECTION_END_DT":"09/28/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"94.25","SUM_TOTAL_ON_SITE_HOURS":"60","sourceDate":"2007-07-02"},{"SOURCE_ROW_NUMBER":"146559","EVENT_NO":"4188859","INSPECTION_BEGIN_DT":"04/19/2007","INSPECTION_END_DT":"04/19/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":".75","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"1015169","EVENT_NO":"4194245","INSPECTION_BEGIN_DT":"04/04/2007","INSPECTION_END_DT":"04/04/2007","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2007-04-04"},{"SOURCE_ROW_NUMBER":"490472","EVENT_NO":"4438196","INSPECTION_BEGIN_DT":"04/02/2007","INSPECTION_END_DT":"05/17/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.25","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2007-04-02"},{"SOURCE_ROW_NUMBER":"907899","EVENT_NO":"4438027","INSPECTION_BEGIN_DT":"02/05/2007","INSPECTION_END_DT":"03/01/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"62.25","SUM_TOTAL_ON_SITE_HOURS":"37.5","sourceDate":"2007-02-05"},{"SOURCE_ROW_NUMBER":"195263","EVENT_NO":"4189693","INSPECTION_BEGIN_DT":"12/27/2006","INSPECTION_END_DT":"12/27/2006","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2006-12-27"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008-Q1":{"hours":6240,"employees":13,"production":12690},"2007-Q4":{"hours":5200,"employees":10,"production":15301},"2007-Q3":{"hours":2200,"employees":11,"production":3361}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007":{"hours":7400,"employees":11,"production":18662},"2008":{"hours":6240,"employees":13,"production":12690}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":18,"firstDate":"2006-10-26","lastDate":"2007-11-07","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":940,"pelDoseTotal":634},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"94036","EVENT_NO":"4182281","SURVEY_DATE":"11/07/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"54","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2007-11-07"},{"SOURCE_ROW_NUMBER":"94035","EVENT_NO":"4182281","SURVEY_DATE":"11/07/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"77","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2007-11-07"},{"SOURCE_ROW_NUMBER":"94034","EVENT_NO":"4182281","SURVEY_DATE":"11/07/2007","OCCUPATION_CD_DESC":"UTILITY MAN","ACT_DOSE_85":"64","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2007-11-07"},{"SOURCE_ROW_NUMBER":"94033","EVENT_NO":"4182281","SURVEY_DATE":"11/07/2007","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"42","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2007-11-07"},{"SOURCE_ROW_NUMBER":"94032","EVENT_NO":"4182281","SURVEY_DATE":"11/07/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"37","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2007-11-07"},{"SOURCE_ROW_NUMBER":"94031","EVENT_NO":"4182281","SURVEY_DATE":"10/29/2007","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","ACT_DOSE_85":"55","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2007-10-29"},{"SOURCE_ROW_NUMBER":"94030","EVENT_NO":"4182281","SURVEY_DATE":"10/29/2007","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"018","ACT_DOSE_85":"35","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2007-10-29"},{"SOURCE_ROW_NUMBER":"94047","EVENT_NO":"4438201","SURVEY_DATE":"09/20/2007","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"28","PEL_DOSE_90":"13","SURVEY_TYPE":"I","sourceDate":"2007-09-20"},{"SOURCE_ROW_NUMBER":"94046","EVENT_NO":"4438201","SURVEY_DATE":"09/20/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"55","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2007-09-20"},{"SOURCE_ROW_NUMBER":"94045","EVENT_NO":"4438201","SURVEY_DATE":"09/20/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"35","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2007-09-20"},{"SOURCE_ROW_NUMBER":"94044","EVENT_NO":"4438201","SURVEY_DATE":"09/20/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"57","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2007-09-20"},{"SOURCE_ROW_NUMBER":"94043","EVENT_NO":"4438201","SURVEY_DATE":"09/20/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"124","PEL_DOSE_90":"108","SURVEY_TYPE":"I","sourceDate":"2007-09-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":4,"firstDate":"2006-10-26","lastDate":"2008-03-19","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":7.8,"validSamples":4,"quartzPctTotal":20},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"132820","CASSETTE_NO":"57691766","SAMPLE_DT":"03/19/2008","QUARTZ_PCT":"04.8","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-03-19"},{"SOURCE_ROW_NUMBER":"114618","CASSETTE_NO":"57686990","SAMPLE_DT":"11/07/2007","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-11-07"},{"SOURCE_ROW_NUMBER":"10895","CASSETTE_NO":"57729579","SAMPLE_DT":"09/20/2007","QUARTZ_PCT":"07.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-09-20"},{"SOURCE_ROW_NUMBER":"155215","CASSETTE_NO":"57634081","SAMPLE_DT":"10/26/2006","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-10-26"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":172,"firstDate":"2006-10-25","lastDate":"2008-05-08","metrics":{"ss":75,"amountDue":254016,"contested":0,"amountPaid":3926.8,"recentRows":0,"section104d":6,"unterminated":2,"proposedPenalty":254016},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1108798","VIOLATION_NO":"6658960","VIOLATION_ISSUE_DT":"05/08/2008","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/08/2008","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-05-08"},{"SOURCE_ROW_NUMBER":"1108800","VIOLATION_NO":"6655333","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Highly","INJ_ILLNESS":"Fatal","NO_AFFECTED":"7","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/23/2008","PROPOSED_PENALTY":"60000","AMOUNT_DUE":"60000","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108797","VIOLATION_NO":"6657672","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/08/2008","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108796","VIOLATION_NO":"6657671","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2008","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108795","VIOLATION_NO":"6657670","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"N","PART_SECTION":"75.1714-3(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2008","PROPOSED_PENALTY":"207","AMOUNT_DUE":"207","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108794","VIOLATION_NO":"6657669","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/23/2008","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108793","VIOLATION_NO":"6657668","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"N","PART_SECTION":"75.807","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108792","VIOLATION_NO":"6657667","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"N","PART_SECTION":"75.1505(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"Fatal","NO_AFFECTED":"7","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/08/2008","PROPOSED_PENALTY":"460","AMOUNT_DUE":"460","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108791","VIOLATION_NO":"6657666","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"Y","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"05/08/2008","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108790","VIOLATION_NO":"6657665","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/08/2008","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108789","VIOLATION_NO":"6657664","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/08/2008","PROPOSED_PENALTY":"285","AMOUNT_DUE":"285","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"},{"SOURCE_ROW_NUMBER":"1108788","VIOLATION_NO":"6657663","VIOLATION_ISSUE_DT":"04/30/2008","SIG_SUB":"N","PART_SECTION":"75.1101-11","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2008","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2008-04-30"}]}],"safety":{"href":"/api/v1/mines/1519042/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519042/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","heading":"Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-3","part":"75","subchapter":"O","subpart":"R","id":"75.1714-3","citation":"30 CFR 75.1714-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.807","heading":"Installation of high-voltage transmission cables.","id":"75.807","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.807","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"I","subpartHeading":"Subpart I—Underground High-Voltage Distribution","text":"[Statutory Provisions]\n\nAll underground high-voltage transmission cables shall be installed only in regularly inspected air courses and haulageways, and shall be covered, buried, or placed so as to afford protection against damage, guarded where men regularly work or pass under them unless they are 6 1/2 feet or more above the floor or rail, securely anchored, properly insulated, and guarded at ends, and covered, insulated, or placed to prevent contact with trolley wires and other low-voltage circuits.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1505","heading":"Escapeway maps.","id":"75.1505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1505","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"P","subpartHeading":"Subpart P—Mine Emergencies","text":"(a) Content and accessibility. An escapeway map shall show the designated escapeways from the working sections or the miners' work stations to the surface or the exits at the bottom of the shaft or slope, refuge alternatives, and SCSR storage locations. The escapeway map shall be posted or readily accessible for all miners—\n\n(1) In each working section;\n\n(2) In each area where mechanized mining equipment is being installed or removed;\n\n(3) At the refuge alternative; and\n\n(4) At a surface location of the mine where miners congregate, such as at the mine bulletin board, bathhouse, or waiting room.\n\n(b) Keeping maps current. All maps shall be kept up-to-date and any change in route of travel, location of doors, location of refuge alternatives, or direction of airflow shall be shown on the maps by the end of the shift on which the change is made.\n\n(c) Informing affected miners. Miners underground on a shift when any such change is made shall be notified immediately of the change and other affected miners shall be informed of the change before entering the underground areas of the mine.\n\n[71 FR 71452, Dec. 8, 2006, as amended at 73 FR 80698, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","heading":"Inspection of water sprinkler systems.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1101-11","part":"75","subchapter":"O","subpart":"L","id":"75.1101-11","citation":"30 CFR 75.1101-11","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519042","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}