{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519033","name":"#5","status":"Abandoned and Sealed","status_date":"2009-12-14","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Teaberry","operator_id":"0050700","operator_name":"RV Mining, LLC","controller_id":"0041030","controller_name":"Randall G  Vance","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.391388,"longitude":-82.628333},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":675},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519033","name":"#5"},"operator":{"type":"operator","id":"0050700","name":"RV Mining, LLC"},"controller":{"type":"controller","id":"0041030","name":"Randall G  Vance"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041030","name":"Randall G  Vance"},"object":{"type":"mine","id":"1519033","name":"#5"},"validFrom":"2002-09-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519033|0041030|2002-09-10|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050700","name":"RV Mining, LLC"},"object":{"type":"mine","id":"1519033","name":"#5"},"validFrom":"2006-08-10","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519033|0050700|2006-08-10|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041030","name":"Randall G  Vance"},"object":{"type":"operator","id":"0050700","name":"RV Mining, LLC"},"validFrom":"2006-08-10","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519033","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519033|0050700|2006-08-10|0041030|2002-09-10|1225"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2008-01-08","lastDate":"2008-08-14","metrics":{"daysLost":79,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"225169","DOCUMENT_NO":"220082390036","ACCIDENT_DT":"08/14/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"28","NARRATIVE":"Worker was drilling top, a piece of rock slid down steel striking worker on left wrist. Worker finished his shift.","sourceDate":"2008-08-14"},{"SOURCE_ROW_NUMBER":"177913","DOCUMENT_NO":"220080250062","ACCIDENT_DT":"01/16/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Bodily reaction, NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Walking around tailpiece and knee gave out on him. Fell to ground, said knee was hurting.","sourceDate":"2008-01-16"},{"SOURCE_ROW_NUMBER":"199308","DOCUMENT_NO":"220080250060","ACCIDENT_DT":"01/08/2008","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"51","NARRATIVE":"Going in on mantrip, scoop bucket. Stopped to get out at head drive, getting out of scoop bucket, had hand on side of bucket and a personnel buggy rolled into scoop bucket. A pinched finger and broken finger.","sourceDate":"2008-01-08"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2009-12-14","lastDate":"2009-12-14","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":186,"firstDate":"2006-12-05","lastDate":"2009-07-09","metrics":{"ss":85,"delinquent":186,"recentRows":0,"paidPenalty":25182.1,"proposedPenalty":74505,"currentAssessment":74505},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1027680","VIOLATION_NO":"8225196","ISSUE_DT":"07/09/2009","CFR_STANDARD_CD":"75.1711-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-07-09"},{"SOURCE_ROW_NUMBER":"1028778","VIOLATION_NO":"8224911","ISSUE_DT":"05/11/2009","CFR_STANDARD_CD":"77.208(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"1028777","VIOLATION_NO":"8224907","ISSUE_DT":"04/24/2009","CFR_STANDARD_CD":"75.203(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-04-24"},{"SOURCE_ROW_NUMBER":"1027879","VIOLATION_NO":"8224149","ISSUE_DT":"03/23/2009","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-03-23"},{"SOURCE_ROW_NUMBER":"1027874","VIOLATION_NO":"8221170","ISSUE_DT":"02/05/2009","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-05"},{"SOURCE_ROW_NUMBER":"1027873","VIOLATION_NO":"8221169","ISSUE_DT":"02/05/2009","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1203.00","CURRENT_ASSESSMENT_AMT":"1203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-05"},{"SOURCE_ROW_NUMBER":"1027872","VIOLATION_NO":"8221168","ISSUE_DT":"02/05/2009","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-05"},{"SOURCE_ROW_NUMBER":"1026473","VIOLATION_NO":"8223862","ISSUE_DT":"02/02/2009","CFR_STANDARD_CD":"75.506","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"1026472","VIOLATION_NO":"8223861","ISSUE_DT":"02/02/2009","CFR_STANDARD_CD":"77.516","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"1026471","VIOLATION_NO":"8223852","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"75.523-3(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"473.00","CURRENT_ASSESSMENT_AMT":"473.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1026470","VIOLATION_NO":"8223851","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"75.1107-9","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1026469","VIOLATION_NO":"8223850","ISSUE_DT":"01/26/2009","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2009-01-26"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":190,"firstDate":"2006-10-23","lastDate":"2009-04-17","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":32,"validSamples":158,"maxConcentration":20.978,"concentrationTotal":239.32},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1056536","CASS_NUM":"50988430","SMP_TAKEN_DT":"4/17/2009","CONC":".166","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-04-17"},{"SOURCE_ROW_NUMBER":"301801","CASS_NUM":"50983300","SMP_TAKEN_DT":"4/16/2009","CONC":".191","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-04-16"},{"SOURCE_ROW_NUMBER":"827501","CASS_NUM":"50983294","SMP_TAKEN_DT":"4/15/2009","CONC":".08","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-04-15"},{"SOURCE_ROW_NUMBER":"131995","CASS_NUM":"50988645","SMP_TAKEN_DT":"4/14/2009","CONC":".162","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-04-14"},{"SOURCE_ROW_NUMBER":"776269","CASS_NUM":"50988634","SMP_TAKEN_DT":"4/13/2009","CONC":".08","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-04-13"},{"SOURCE_ROW_NUMBER":"1595092","CASS_NUM":"57785311","SMP_TAKEN_DT":"2/24/2009","CONC":".692","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-02-24"},{"SOURCE_ROW_NUMBER":"807876","CASS_NUM":"57785231","SMP_TAKEN_DT":"2/24/2009","CONC":".498","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-02-24"},{"SOURCE_ROW_NUMBER":"542746","CASS_NUM":"57785283","SMP_TAKEN_DT":"2/24/2009","CONC":".099","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-02-24"},{"SOURCE_ROW_NUMBER":"175977","CASS_NUM":"57785268","SMP_TAKEN_DT":"2/24/2009","CONC":"1.266","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-02-24"},{"SOURCE_ROW_NUMBER":"104375","CASS_NUM":"57785258","SMP_TAKEN_DT":"2/24/2009","CONC":".326","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-02-24"},{"SOURCE_ROW_NUMBER":"54157","CASS_NUM":"57785228","SMP_TAKEN_DT":"2/24/2009","CONC":"1.063","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-02-24"},{"SOURCE_ROW_NUMBER":"1047878","CASS_NUM":"50988444","SMP_TAKEN_DT":"2/13/2009","CONC":"1.162","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2009-02-13"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2006-08-10","lastDate":"2006-08-10","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":34,"firstDate":"2006-08-15","lastDate":"2009-10-07","metrics":{"inspectors":63,"recentRows":0,"onSiteHours":874,"inspectionHours":1440.5,"inspectionSamples":185},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"213261","EVENT_NO":"4192204","INSPECTION_BEGIN_DT":"10/07/2009","INSPECTION_END_DT":"10/07/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2009-10-07"},{"SOURCE_ROW_NUMBER":"988068","EVENT_NO":"4191332","INSPECTION_BEGIN_DT":"07/09/2009","INSPECTION_END_DT":"08/05/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"22","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2009-07-09"},{"SOURCE_ROW_NUMBER":"654917","EVENT_NO":"4196911","INSPECTION_BEGIN_DT":"06/10/2009","INSPECTION_END_DT":"06/10/2009","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2009-06-10"},{"SOURCE_ROW_NUMBER":"568999","EVENT_NO":"4191673","INSPECTION_BEGIN_DT":"04/22/2009","INSPECTION_END_DT":"05/29/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"39","SUM_TOTAL_ON_SITE_HOURS":"19.25","sourceDate":"2009-04-22"},{"SOURCE_ROW_NUMBER":"918639","EVENT_NO":"4191433","INSPECTION_BEGIN_DT":"03/23/2009","INSPECTION_END_DT":"03/25/2009","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"23","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2009-03-23"},{"SOURCE_ROW_NUMBER":"609555","EVENT_NO":"4191430","INSPECTION_BEGIN_DT":"01/21/2009","INSPECTION_END_DT":"03/16/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"73","SUM_TOTAL_ON_SITE_HOURS":"47.5","sourceDate":"2009-01-21"},{"SOURCE_ROW_NUMBER":"378370","EVENT_NO":"4191119","INSPECTION_BEGIN_DT":"12/31/2008","INSPECTION_END_DT":"02/12/2009","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"80.5","SUM_TOTAL_ON_SITE_HOURS":"52.5","sourceDate":"2008-12-31"},{"SOURCE_ROW_NUMBER":"33289","EVENT_NO":"4191421","INSPECTION_BEGIN_DT":"10/20/2008","INSPECTION_END_DT":"10/22/2008","ACTIVITY_CODE":"E04","ACTIVITY":"Verbal Hazard Complaint Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2008-10-20"},{"SOURCE_ROW_NUMBER":"1144209","EVENT_NO":"4191554","INSPECTION_BEGIN_DT":"10/01/2008","INSPECTION_END_DT":"12/31/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"130.75","SUM_TOTAL_ON_SITE_HOURS":"89.75","sourceDate":"2008-10-01"},{"SOURCE_ROW_NUMBER":"381821","EVENT_NO":"4191553","INSPECTION_BEGIN_DT":"09/30/2008","INSPECTION_END_DT":"09/30/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14.5","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2008-09-30"},{"SOURCE_ROW_NUMBER":"677113","EVENT_NO":"4191261","INSPECTION_BEGIN_DT":"09/10/2008","INSPECTION_END_DT":"09/30/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"95","SUM_TOTAL_ON_SITE_HOURS":"60.5","sourceDate":"2008-09-10"},{"SOURCE_ROW_NUMBER":"1156157","EVENT_NO":"4184094","INSPECTION_BEGIN_DT":"08/27/2008","INSPECTION_END_DT":"08/28/2008","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"12.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2008-08-27"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":36,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2009-Q2":{"hours":2857,"employees":16,"production":3168},"2009-Q1":{"hours":8286,"employees":18,"production":11948},"2008-Q4":{"hours":6926,"employees":14,"production":14236},"2008-Q3":{"hours":7322,"employees":17,"production":12771},"2008-Q2":{"hours":9086,"employees":16,"production":15230},"2008-Q1":{"hours":6289,"employees":14,"production":14187},"2007-Q4":{"hours":6900,"employees":15,"production":14665},"2007-Q3":{"hours":6976,"employees":17,"production":12496},"2007-Q2":{"hours":6472,"employees":13,"production":16911},"2007-Q1":{"hours":7494,"employees":18,"production":14068},"2006-Q4":{"hours":6789,"employees":15,"production":14213},"2006-Q3":{"hours":1640,"employees":10,"production":4923}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":8429,"employees":13,"production":19136},"2007":{"hours":27842,"employees":16,"production":58140},"2008":{"hours":29623,"employees":15,"production":56424},"2009":{"hours":11143,"employees":17,"production":15116}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2006-12-11","lastDate":"2008-11-24","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":830,"pelDoseTotal":534},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"93905","EVENT_NO":"4191554","SURVEY_DATE":"11/24/2008","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"120","ACT_DOSE_85":"56","PEL_DOSE_90":"32","SURVEY_TYPE":"I","sourceDate":"2008-11-24"},{"SOURCE_ROW_NUMBER":"93904","EVENT_NO":"4191554","SURVEY_DATE":"11/24/2008","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"120","ACT_DOSE_85":"64","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2008-11-24"},{"SOURCE_ROW_NUMBER":"93903","EVENT_NO":"4191554","SURVEY_DATE":"11/24/2008","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"46","PEL_DOSE_90":"18","SURVEY_TYPE":"I","sourceDate":"2008-11-24"},{"SOURCE_ROW_NUMBER":"93902","EVENT_NO":"4191554","SURVEY_DATE":"11/24/2008","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"40","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2008-11-24"},{"SOURCE_ROW_NUMBER":"93901","EVENT_NO":"4191554","SURVEY_DATE":"11/24/2008","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"59","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2008-11-24"},{"SOURCE_ROW_NUMBER":"93895","EVENT_NO":"4189896","SURVEY_DATE":"10/15/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"41","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"93894","EVENT_NO":"4189896","SURVEY_DATE":"10/15/2007","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"52","PEL_DOSE_90":"29","SURVEY_TYPE":"I","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"93893","EVENT_NO":"4189896","SURVEY_DATE":"10/15/2007","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"77","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"93892","EVENT_NO":"4189896","SURVEY_DATE":"10/15/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"119","ACT_DOSE_85":"61","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"93891","EVENT_NO":"4189896","SURVEY_DATE":"10/15/2007","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"78","PEL_DOSE_90":"66","SURVEY_TYPE":"I","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"93900","EVENT_NO":"4190064","SURVEY_DATE":"12/11/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"55","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2006-12-11"},{"SOURCE_ROW_NUMBER":"93899","EVENT_NO":"4190064","SURVEY_DATE":"12/11/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"63","PEL_DOSE_90":"54","SURVEY_TYPE":"I","sourceDate":"2006-12-11"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":7,"firstDate":"2006-12-11","lastDate":"2009-02-24","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":7.4,"validSamples":7,"quartzPctTotal":26.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"127607","CASSETTE_NO":"57785268","SAMPLE_DT":"02/24/2009","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2009-02-24"},{"SOURCE_ROW_NUMBER":"118942","CASSETTE_NO":"57725275","SAMPLE_DT":"09/30/2008","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-09-30"},{"SOURCE_ROW_NUMBER":"150613","CASSETTE_NO":"57744844","SAMPLE_DT":"06/24/2008","QUARTZ_PCT":"01.8","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-06-24"},{"SOURCE_ROW_NUMBER":"69031","CASSETTE_NO":"57687221","SAMPLE_DT":"10/15/2007","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-10-15"},{"SOURCE_ROW_NUMBER":"107495","CASSETTE_NO":"57703413","SAMPLE_DT":"04/10/2007","QUARTZ_PCT":"03.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-04-10"},{"SOURCE_ROW_NUMBER":"138278","CASSETTE_NO":"57703630","SAMPLE_DT":"01/16/2007","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-01-16"},{"SOURCE_ROW_NUMBER":"60421","CASSETTE_NO":"57662026","SAMPLE_DT":"12/11/2006","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-12-11"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":189,"firstDate":"2006-12-05","lastDate":"2009-07-09","metrics":{"ss":85,"amountDue":74505,"contested":0,"amountPaid":25182.1,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":74505},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1108346","VIOLATION_NO":"8225196","VIOLATION_ISSUE_DT":"07/09/2009","SIG_SUB":"N","PART_SECTION":"75.1711-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/17/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-07-09"},{"SOURCE_ROW_NUMBER":"1108344","VIOLATION_NO":"8224911","VIOLATION_ISSUE_DT":"05/11/2009","SIG_SUB":"N","PART_SECTION":"77.208(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/11/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-05-11"},{"SOURCE_ROW_NUMBER":"1108343","VIOLATION_NO":"8224907","VIOLATION_ISSUE_DT":"04/24/2009","SIG_SUB":"Y","PART_SECTION":"75.203(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/24/2009","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-04-24"},{"SOURCE_ROW_NUMBER":"1108321","VIOLATION_NO":"8224149","VIOLATION_ISSUE_DT":"03/23/2009","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/25/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-03-23"},{"SOURCE_ROW_NUMBER":"1108449","VIOLATION_NO":"8223873","VIOLATION_ISSUE_DT":"02/09/2009","PART_SECTION":"75.523-3(b)","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"03/23/2009","CONTESTED_IND":"N","sourceDate":"2009-02-09"},{"SOURCE_ROW_NUMBER":"1108319","VIOLATION_NO":"8221170","VIOLATION_ISSUE_DT":"02/05/2009","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/05/2009","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-02-05"},{"SOURCE_ROW_NUMBER":"1108318","VIOLATION_NO":"8221169","VIOLATION_ISSUE_DT":"02/05/2009","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"1203","AMOUNT_DUE":"1203","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-02-05"},{"SOURCE_ROW_NUMBER":"1108317","VIOLATION_NO":"8221168","VIOLATION_ISSUE_DT":"02/05/2009","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-02-05"},{"SOURCE_ROW_NUMBER":"1108448","VIOLATION_NO":"8223862","VIOLATION_ISSUE_DT":"02/02/2009","SIG_SUB":"N","PART_SECTION":"75.506","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"1108447","VIOLATION_NO":"8223861","VIOLATION_ISSUE_DT":"02/02/2009","SIG_SUB":"N","PART_SECTION":"77.516","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-02-02"},{"SOURCE_ROW_NUMBER":"1108446","VIOLATION_NO":"8223852","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"Y","PART_SECTION":"75.523-3(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"473","AMOUNT_DUE":"473","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-01-26"},{"SOURCE_ROW_NUMBER":"1108445","VIOLATION_NO":"8223851","VIOLATION_ISSUE_DT":"01/26/2009","SIG_SUB":"N","PART_SECTION":"75.1107-9","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/26/2009","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2009-01-26"}]}],"safety":{"href":"/api/v1/mines/1519033/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519033/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Sealing of slope or drift openings.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711-2","part":"75","subchapter":"O","subpart":"R","id":"75.1711-2","citation":"30 CFR 75.1711-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","heading":"Mining methods.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.203","part":"75","subchapter":"O","subpart":"C","id":"75.203","citation":"30 CFR 75.203","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":1},{"chapter":"I","heading":"Electric face equipment; requirements for permissibility.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.506","part":"75","subchapter":"O","subpart":"F","id":"75.506","citation":"30 CFR 75.506","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Electric wiring and equipment; installation and maintenance.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.516","part":"77","subchapter":"O","subpart":"F","id":"77.516","citation":"30 CFR 77.516","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-9","heading":"Dry chemical devices; capacity; minimum requirements.","id":"75.1107-9","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-9","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Dry chemical fire extinguishing systems used on underground equipment shall be of the multipurpose powder-type and shall include the following:\n\n(1) The system including all hose and nozzles shall be protected against the entrance of moisture, dust, or dirt;\n\n(2) The system shall be guarded against damage during operation of the equipment protected;\n\n(3) Hose and pipe shall be as short as possible; the distance between the chemical container and furthest nozzle shall not exceed 50 feet;\n\n(4) Hose, piping, and fittings between the actuator and the chemical container shall have a bursting pressure of 500 pounds per square inch (gage) or higher; the hose, piping, and fittings between the chemical container and the nozzles shall have a bursting pressure of 300 pounds per square inch (gage) or higher and\n\n(5) The system shall discharge in 1 minute or less, for quantities less than 50 pounds (nominal) 1 and in less than 2 minutes for quantities more than 50 pounds;\n\n1 Many dry chemical systems were originally designed for sodium bicarbonate before all-purpose chemical (ammonium phosphate) was shown to be more effective. Sodium bicarbonate is denser than ammonium phosphate; hence, for example, a 50-pound system designed for the sodium bicarbonate will hold slightly more by weight than all-purpose dry chemical (ammonium phosphate) by weight. The word “nominal” is used in § 75.1107-9 to express the approximate weight in pounds of all-purpose dry chemical.\n\n(b) On unattended underground equipment, the number of pounds of dry chemical employed by the system shall be not less than 1 pound per square foot of top surface area of the equipment; however, the minimum amount in any system shall be 20 pounds (nominal). The discharge shall be directed into and on potentially hazardous locations of the equipment.\n\n(c) On attended underground equipment, the number of pounds (nominal) employed by the system shall equal 5 times the total number of hazardous locations; however, the minimum amount in any system shall not be less than the following, except that systems on haulage vehicles installed prior to the effective date of this section may contain 20 pounds (nominal).\n\nType of equipment Dry chemical pounds (nominal) (1) Cutting machines 40 (2) Continuous miners 40 (3) Haulage vehicles 30 (4) All other attended equipment 20\n\n(d) The amount of dry chemical discharged into the cable reel compartments of attended underground equipment shall be approximately 25 percent of the total amount required to be discharged by the system; however, the quantity discharged into cable reel compartments need not exceed 10 pounds.\n\n[37 FR 15302, July 29, 1972]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519033","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}