{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1519000","name":"#4B","status":"Abandoned and Sealed","status_date":"2007-10-30","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Turkey Creek","operator_id":"P23909","operator_name":"North Star Mining Inc","controller_id":"C05558","controller_name":"Carl  Kirk","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.488055,"longitude":-82.786388},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":269},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1519000","name":"#4B"},"operator":{"type":"operator","id":"P23909","name":"North Star Mining Inc"},"controller":{"type":"controller","id":"C05558","name":"Carl  Kirk"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C05558","name":"Carl  Kirk et al"},"object":{"type":"mine","id":"1519000","name":"#4B"},"validFrom":"1998-02-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519000|C05558|1998-02-19|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23909","name":"North Star Mining Inc"},"object":{"type":"mine","id":"1519000","name":"#4B"},"validFrom":"2006-06-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519000|P23909|2006-06-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C05558","name":"Carl  Kirk et al"},"object":{"type":"operator","id":"P23909","name":"North Star Mining Inc"},"validFrom":"2006-06-05","validTo":null,"current":true,"derived":true,"evidenceMineId":"1519000","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1519000|P23909|2006-06-05|C05558|1998-02-19|69167"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":2,"firstDate":"2006-12-09","lastDate":"2007-04-18","metrics":{"daysLost":6,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":1,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"199304","DOCUMENT_NO":"220071140072","ACCIDENT_DT":"04/18/2007","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Greaser, Grease man, Oiler, Lube man, Dragline oiler","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Changing a foot shaft and twisted knee.","sourceDate":"2007-04-18"},{"SOURCE_ROW_NUMBER":"18722","DOCUMENT_NO":"220063520068","ACCIDENT_DT":"12/09/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Bent over to get dust box sealed, drawrock fell hitting him in the lower back.","sourceDate":"2006-12-09"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-10-30","lastDate":"2007-10-30","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":73,"firstDate":"2006-06-20","lastDate":"2007-07-27","metrics":{"ss":26,"delinquent":73,"recentRows":0,"paidPenalty":3061,"proposedPenalty":10443,"currentAssessment":10443},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1023366","VIOLATION_NO":"7449565","ISSUE_DT":"07/27/2007","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-27"},{"SOURCE_ROW_NUMBER":"1023365","VIOLATION_NO":"7449564","ISSUE_DT":"07/25/2007","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"540.00","CURRENT_ASSESSMENT_AMT":"540.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1023364","VIOLATION_NO":"7449563","ISSUE_DT":"07/25/2007","CFR_STANDARD_CD":"75.333(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1023363","VIOLATION_NO":"7449562","ISSUE_DT":"07/25/2007","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1023362","VIOLATION_NO":"7449561","ISSUE_DT":"07/25/2007","CFR_STANDARD_CD":"75.807","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"108.00","CURRENT_ASSESSMENT_AMT":"108.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1023308","VIOLATION_NO":"7444369","ISSUE_DT":"05/21/2007","CFR_STANDARD_CD":"77.505","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-21"},{"SOURCE_ROW_NUMBER":"1023307","VIOLATION_NO":"7444368","ISSUE_DT":"05/16/2007","CFR_STANDARD_CD":"75.1103","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"1023306","VIOLATION_NO":"7444367","ISSUE_DT":"05/16/2007","CFR_STANDARD_CD":"75.701","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"1023305","VIOLATION_NO":"7444366","ISSUE_DT":"05/16/2007","CFR_STANDARD_CD":"75.523-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"1023304","VIOLATION_NO":"7444365","ISSUE_DT":"05/15/2007","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-15"},{"SOURCE_ROW_NUMBER":"1023303","VIOLATION_NO":"7444364","ISSUE_DT":"05/15/2007","CFR_STANDARD_CD":"75.900","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-15"},{"SOURCE_ROW_NUMBER":"1023302","VIOLATION_NO":"7444363","ISSUE_DT":"05/15/2007","CFR_STANDARD_CD":"75.902","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-15"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":59,"firstDate":"2006-09-25","lastDate":"2007-07-17","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":59,"maxConcentration":2.502,"concentrationTotal":39.23},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"549899","CASS_NUM":"50901197","SMP_TAKEN_DT":"7/17/2007","CONC":".109","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-07-17"},{"SOURCE_ROW_NUMBER":"951901","CASS_NUM":"57713363","SMP_TAKEN_DT":"6/27/2007","CONC":".603","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"822963","CASS_NUM":"57713336","SMP_TAKEN_DT":"6/27/2007","CONC":".389","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SECTION FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"788233","CASS_NUM":"57713273","SMP_TAKEN_DT":"6/27/2007","CONC":".386","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"539449","CASS_NUM":"57713366","SMP_TAKEN_DT":"6/27/2007","CONC":".714","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"135372","CASS_NUM":"57713291","SMP_TAKEN_DT":"6/27/2007","CONC":".543","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"100809","CASS_NUM":"57713326","SMP_TAKEN_DT":"6/27/2007","CONC":"1.095","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"871184","CASS_NUM":"50876938","SMP_TAKEN_DT":"5/29/2007","CONC":".287","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-29"},{"SOURCE_ROW_NUMBER":"469647","CASS_NUM":"50876905","SMP_TAKEN_DT":"5/18/2007","CONC":".222","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-18"},{"SOURCE_ROW_NUMBER":"313695","CASS_NUM":"50876895","SMP_TAKEN_DT":"5/17/2007","CONC":".287","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-17"},{"SOURCE_ROW_NUMBER":"1618102","CASS_NUM":"50876921","SMP_TAKEN_DT":"5/16/2007","CONC":".26","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"812476","CASS_NUM":"50901229","SMP_TAKEN_DT":"5/15/2007","CONC":".3","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-15"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":4,"firstDate":"2006-08-22","lastDate":"2006-08-22","metrics":{"linkedIssuances":4},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2006-06-05","lastDate":"2006-06-05","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":12,"firstDate":"2006-06-14","lastDate":"2008-02-20","metrics":{"inspectors":21,"recentRows":0,"onSiteHours":292,"inspectionHours":442.25,"inspectionSamples":22},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"787401","EVENT_NO":"4190291","INSPECTION_BEGIN_DT":"02/20/2008","INSPECTION_END_DT":"02/20/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2008-02-20"},{"SOURCE_ROW_NUMBER":"577313","EVENT_NO":"4190285","INSPECTION_BEGIN_DT":"10/05/2007","INSPECTION_END_DT":"10/05/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2007-10-05"},{"SOURCE_ROW_NUMBER":"835852","EVENT_NO":"4190529","INSPECTION_BEGIN_DT":"07/25/2007","INSPECTION_END_DT":"08/14/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"25.5","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"810731","EVENT_NO":"4190513","INSPECTION_BEGIN_DT":"04/18/2007","INSPECTION_END_DT":"06/27/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"116.5","SUM_TOTAL_ON_SITE_HOURS":"79.5","sourceDate":"2007-04-18"},{"SOURCE_ROW_NUMBER":"402494","EVENT_NO":"4192628","INSPECTION_BEGIN_DT":"03/12/2007","INSPECTION_END_DT":"03/23/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"59","SUM_TOTAL_ON_SITE_HOURS":"38.75","sourceDate":"2007-03-12"},{"SOURCE_ROW_NUMBER":"65143","EVENT_NO":"4193605","INSPECTION_BEGIN_DT":"01/10/2007","INSPECTION_END_DT":"01/12/2007","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2007-01-10"},{"SOURCE_ROW_NUMBER":"887305","EVENT_NO":"4189345","INSPECTION_BEGIN_DT":"10/02/2006","INSPECTION_END_DT":"12/20/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"115.5","SUM_TOTAL_ON_SITE_HOURS":"81","sourceDate":"2006-10-02"},{"SOURCE_ROW_NUMBER":"129251","EVENT_NO":"4189818","INSPECTION_BEGIN_DT":"07/12/2006","INSPECTION_END_DT":"09/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"53.5","SUM_TOTAL_ON_SITE_HOURS":"36.75","sourceDate":"2006-07-12"},{"SOURCE_ROW_NUMBER":"188002","EVENT_NO":"4189911","INSPECTION_BEGIN_DT":"06/27/2006","INSPECTION_END_DT":"06/27/2006","ACTIVITY_CODE":"E15","ACTIVITY":"Compliance Follow-up Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"1094635","EVENT_NO":"4187141","INSPECTION_BEGIN_DT":"06/22/2006","INSPECTION_END_DT":"07/05/2006","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"30","SUM_TOTAL_ON_SITE_HOURS":"16","sourceDate":"2006-06-22"},{"SOURCE_ROW_NUMBER":"1059158","EVENT_NO":"4189910","INSPECTION_BEGIN_DT":"06/20/2006","INSPECTION_END_DT":"06/21/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2006-06-20"},{"SOURCE_ROW_NUMBER":"590477","EVENT_NO":"4438347","INSPECTION_BEGIN_DT":"06/14/2006","INSPECTION_END_DT":"06/14/2006","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2006-06-14"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q4":{"hours":0,"employees":0,"production":0},"2007-Q3":{"hours":5014,"employees":32,"production":10025},"2007-Q2":{"hours":16050,"employees":40,"production":30827},"2007-Q1":{"hours":16694,"employees":35,"production":38964},"2006-Q4":{"hours":17475,"employees":35,"production":39893},"2006-Q3":{"hours":13953,"employees":38,"production":46663},"2006-Q2":{"hours":431,"employees":6,"production":1444}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":6,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":31859,"employees":27,"production":88000},"2007":{"hours":37758,"employees":36,"production":79816}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2007-03-20","lastDate":"2007-04-24","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":939,"pelDoseTotal":830},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"92759","EVENT_NO":"4190513","SURVEY_DATE":"04/24/2007","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"01","MANUFACTURER_CD":"001","ACT_DOSE_85":"60","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"92758","EVENT_NO":"4190513","SURVEY_DATE":"04/24/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"58","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"92757","EVENT_NO":"4190513","SURVEY_DATE":"04/24/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"77","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"92756","EVENT_NO":"4190513","SURVEY_DATE":"04/24/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"80","PEL_DOSE_90":"76","SURVEY_TYPE":"I","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"92755","EVENT_NO":"4190513","SURVEY_DATE":"04/24/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"83","PEL_DOSE_90":"79","SURVEY_TYPE":"I","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"92764","EVENT_NO":"4192628","SURVEY_DATE":"03/20/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (OFF STANDARD)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"104","PEL_DOSE_90":"100","SURVEY_TYPE":"I","sourceDate":"2007-03-20"},{"SOURCE_ROW_NUMBER":"92763","EVENT_NO":"4192628","SURVEY_DATE":"03/20/2007","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"90","PEL_DOSE_90":"78","SURVEY_TYPE":"I","sourceDate":"2007-03-20"},{"SOURCE_ROW_NUMBER":"92762","EVENT_NO":"4192628","SURVEY_DATE":"03/20/2007","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"266","PEL_DOSE_90":"258","SURVEY_TYPE":"I","sourceDate":"2007-03-20"},{"SOURCE_ROW_NUMBER":"92761","EVENT_NO":"4192628","SURVEY_DATE":"03/20/2007","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"01","MANUFACTURER_CD":"001","ACT_DOSE_85":"65","PEL_DOSE_90":"57","SURVEY_TYPE":"I","sourceDate":"2007-03-20"},{"SOURCE_ROW_NUMBER":"92760","EVENT_NO":"4192628","SURVEY_DATE":"03/20/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"56","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2007-03-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":7,"firstDate":"2006-10-11","lastDate":"2007-06-27","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":10.1,"validSamples":7,"quartzPctTotal":57.4},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"151286","CASSETTE_NO":"57713363","SAMPLE_DT":"06/27/2007","QUARTZ_PCT":"07.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"81041","CASSETTE_NO":"20070489","SAMPLE_DT":"06/27/2007","QUARTZ_PCT":"10.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-06-27"},{"SOURCE_ROW_NUMBER":"115696","CASSETTE_NO":"57703362","SAMPLE_DT":"05/02/2007","QUARTZ_PCT":"07.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-05-02"},{"SOURCE_ROW_NUMBER":"74471","CASSETTE_NO":"50876872","SAMPLE_DT":"04/06/2007","QUARTZ_PCT":"10.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-04-06"},{"SOURCE_ROW_NUMBER":"115833","CASSETTE_NO":"57703318","SAMPLE_DT":"03/20/2007","QUARTZ_PCT":"09.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-20"},{"SOURCE_ROW_NUMBER":"42174","CASSETTE_NO":"57703319","SAMPLE_DT":"03/20/2007","QUARTZ_PCT":"06.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-20"},{"SOURCE_ROW_NUMBER":"109356","CASSETTE_NO":"57661935","SAMPLE_DT":"10/11/2006","QUARTZ_PCT":"06.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-10-11"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":73,"firstDate":"2006-06-20","lastDate":"2007-07-27","metrics":{"ss":26,"amountDue":10443,"contested":0,"amountPaid":3061,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":10443},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1102198","VIOLATION_NO":"7449565","VIOLATION_ISSUE_DT":"07/27/2007","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2007","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-07-27"},{"SOURCE_ROW_NUMBER":"1102197","VIOLATION_NO":"7449564","VIOLATION_ISSUE_DT":"07/25/2007","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/25/2007","PROPOSED_PENALTY":"540","AMOUNT_DUE":"540","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1102196","VIOLATION_NO":"7449563","VIOLATION_ISSUE_DT":"07/25/2007","SIG_SUB":"N","PART_SECTION":"75.333(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/25/2007","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1102195","VIOLATION_NO":"7449562","VIOLATION_ISSUE_DT":"07/25/2007","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/27/2007","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1102194","VIOLATION_NO":"7449561","VIOLATION_ISSUE_DT":"07/25/2007","SIG_SUB":"N","PART_SECTION":"75.807","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/25/2007","PROPOSED_PENALTY":"108","AMOUNT_DUE":"108","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-07-25"},{"SOURCE_ROW_NUMBER":"1102158","VIOLATION_NO":"7444369","VIOLATION_ISSUE_DT":"05/21/2007","SIG_SUB":"N","PART_SECTION":"77.505","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-21"},{"SOURCE_ROW_NUMBER":"1102157","VIOLATION_NO":"7444368","VIOLATION_ISSUE_DT":"05/16/2007","SIG_SUB":"N","PART_SECTION":"75.1103","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/21/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"1102156","VIOLATION_NO":"7444367","VIOLATION_ISSUE_DT":"05/16/2007","SIG_SUB":"N","PART_SECTION":"75.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"1102155","VIOLATION_NO":"7444366","VIOLATION_ISSUE_DT":"05/16/2007","SIG_SUB":"N","PART_SECTION":"75.523-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/16/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"1102154","VIOLATION_NO":"7444365","VIOLATION_ISSUE_DT":"05/15/2007","SIG_SUB":"Y","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2007","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-15"},{"SOURCE_ROW_NUMBER":"1102153","VIOLATION_NO":"7444364","VIOLATION_ISSUE_DT":"05/15/2007","SIG_SUB":"Y","PART_SECTION":"75.900","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2007","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-15"},{"SOURCE_ROW_NUMBER":"1102152","VIOLATION_NO":"7444363","VIOLATION_ISSUE_DT":"05/15/2007","SIG_SUB":"N","PART_SECTION":"75.902","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/15/2007","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-15"}]}],"safety":{"href":"/api/v1/mines/1519000/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1519000/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.807","heading":"Installation of high-voltage transmission cables.","id":"75.807","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-I/section-75.807","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"I","subpartHeading":"Subpart I—Underground High-Voltage Distribution","text":"[Statutory Provisions]\n\nAll underground high-voltage transmission cables shall be installed only in regularly inspected air courses and haulageways, and shall be covered, buried, or placed so as to afford protection against damage, guarded where men regularly work or pass under them unless they are 6 1/2 feet or more above the floor or rail, securely anchored, properly insulated, and guarded at ends, and covered, insulated, or placed to prevent contact with trolley wires and other low-voltage circuits.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.505","heading":"Cable fittings; suitability.","id":"77.505","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.505","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Cables shall enter metal frames of motors, splice boxes, and electric compartments only through proper fittings. When insulated wires, other than cables, pass through metal frames, the holes shall be substantially bushed with insulated bushings.","occurrenceCount":1},{"chapter":"I","heading":"Automatic fire warning devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103","part":"75","subchapter":"O","subpart":"L","id":"75.1103","citation":"30 CFR 75.1103","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.701","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","id":"75.701","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-H/section-75.701","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"H","subpartHeading":"Subpart H—Grounding","text":"[Statutory Provisions]\n\nMetallic frames, casings, and other enclosures of electric equipment that can become “alive” through failure of insulation or by contact with energized parts shall be grounded by methods approved by an authorized representative of the Secretary.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.900","heading":"Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit breakers.","id":"75.900","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.900","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nLow- and medium-voltage power circuits serving three-phase alternating current equipment shall be protected by suitable circuit breakers of adequate interrupting capacity which are properly tested and maintained as prescribed by the Secretary. Such breakers shall be equipped with devices to provide protection against undervoltage, grounded phase, short circuit, and overcurrent.","occurrenceCount":1},{"chapter":"I","heading":"Low- and medium-voltage ground check monitor circuits.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.902","part":"75","subchapter":"O","subpart":"J","id":"75.902","citation":"30 CFR 75.902","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1519000","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}