{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518964","name":"Mine #30","status":"Abandoned and Sealed","status_date":"2012-05-15","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Ashcamp","operator_id":"0051241","operator_name":"CAM Mining LLC","controller_id":"0098293","controller_name":"Rhino Resource Partners LP","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.225833,"longitude":-82.537222},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":1907},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518964","name":"Mine #30"},"operator":{"type":"operator","id":"0051241","name":"CAM Mining LLC"},"controller":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041669","name":"Wexford Capital LLC"},"object":{"type":"mine","id":"1518964","name":"Mine #30"},"validFrom":"2003-05-12","validTo":"2010-10-04","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518964|0041669|2003-05-12|2010-10-04"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051241","name":"CAM Mining LLC"},"object":{"type":"mine","id":"1518964","name":"Mine #30"},"validFrom":"2006-01-31","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518964|0051241|2006-01-31|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041669","name":"Wexford Capital LLC"},"object":{"type":"operator","id":"0051241","name":"CAM Mining LLC"},"validFrom":"2006-01-31","validTo":"2010-10-04","current":false,"derived":true,"evidenceMineId":"1518964","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518964|0051241|2006-01-31|0041669|2003-05-12|2907"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"mine","id":"1518964","name":"Mine #30"},"validFrom":"2010-10-05","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518964|0098293|2010-10-05|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0098293","name":"Rhino Resource Partners LP"},"object":{"type":"operator","id":"0051241","name":"CAM Mining LLC"},"validFrom":"2010-10-05","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518964","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518964|0051241|2006-01-31|0098293|2010-10-05|16145"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":21,"firstDate":"2006-09-25","lastDate":"2011-12-26","metrics":{"daysLost":624,"injuries":16,"fatalities":0,"recentRows":0,"restrictedDays":42,"contractorRecords":1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"160706","DOCUMENT_NO":"220113610034","ACCIDENT_DT":"12/26/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall to the walkway or working surface","OCCUPATION":"Security guard, Watchman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"slipped on extention cord box fell on left hip refused medical treatment","sourceDate":"2011-12-26"},{"SOURCE_ROW_NUMBER":"160707","DOCUMENT_NO":"220110940050","ACCIDENT_DT":"03/29/2011","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was making a splice on the shuttle car cable and cut his index finger on his left hand requiring 6 stitches.","sourceDate":"2011-03-29"},{"SOURCE_ROW_NUMBER":"220922","DOCUMENT_NO":"220110470046","ACCIDENT_DT":"02/11/2011","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall has occurred in the left return at spad #126. The fall measured 25' long by 20' wide by 5' thick. Persons, equipment, nor ventilation were involved. This area will not be rehabilitated.","sourceDate":"2011-02-11"},{"SOURCE_ROW_NUMBER":"147818","DOCUMENT_NO":"220110480035","ACCIDENT_DT":"10/06/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"182","NARRATIVE":"Employee was changing boom lift jack when boom fell squeezing his head resulting in multiple fractures.","sourceDate":"2010-10-06"},{"SOURCE_ROW_NUMBER":"212305","DOCUMENT_NO":"220103000039","ACCIDENT_DT":"10/05/2010","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"162","NARRATIVE":"Employee was exiting scoop deck when he slipped and twisted his knee. He was placed on restricted duty on 10/21/10.","sourceDate":"2010-10-05"},{"SOURCE_ROW_NUMBER":"212304","DOCUMENT_NO":"220102110041","ACCIDENT_DT":"07/27/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall has occurred in the intake airway 60 feet inby spad no. 110 in the #3 entry. The fall measured approximately 5' thick, 20' long and 20' wide. Neither persons ventilation or equipment were involved. This area will not be rehabilitated.","sourceDate":"2010-07-27"},{"SOURCE_ROW_NUMBER":"53131","DOCUMENT_NO":"220101660048","ACCIDENT_DT":"06/07/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was removing a canopy from a shuttle car. He was sitting under the canopy & when he removed a bolt, the canopy dislodged & struck him on the right shoulder. EE was taken to the hospital & was diagnosed with a compression fracture of the No. 12 vertebrae. He had a follow up visit with his family physician on 6/8/2010 and returned to work on 6/9/2010.","sourceDate":"2010-06-07"},{"SOURCE_ROW_NUMBER":"242518","DOCUMENT_NO":"220091320038","ACCIDENT_DT":"05/08/2009","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall has occurred 1 crosscut past spad #117 in the return airway, half way between #7 and #9 entries. The fall measured 60' long, 7' high and 20' wide. Persons, ventilation nor equipment were not involved. This area will not be rehabilitated.","sourceDate":"2009-05-08"},{"SOURCE_ROW_NUMBER":"104480","DOCUMENT_NO":"220082630039","ACCIDENT_DT":"08/28/2008","DEGREE_INJURY":"DAYS RESTRICTED ACTIVITY ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE was operating the miner and started to turn around. He was standing in a muddy arae and his boot stuck in the mud, causing him to twist his knee. He finished his shift, continued to work until his appointment with an orthopedic surgeon. All X-rays were negative, but due to pain in squatting, was placed on restricted duty on 9/8/08.","sourceDate":"2008-08-28"},{"SOURCE_ROW_NUMBER":"233820","DOCUMENT_NO":"220082550046","ACCIDENT_DT":"08/26/2008","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Operating a three wheeler, the steering wheel spun around hitting the top of his hand fracturing two fingers.","sourceDate":"2008-08-26"},{"SOURCE_ROW_NUMBER":"272486","DOCUMENT_NO":"220082350052","ACCIDENT_DT":"08/15/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall has occurred in the neutral airway approximately 1.5 miles from the active face. There were no persons, or equipment involved. Ventilation was not affected. This area will not be rehabilitated.","sourceDate":"2008-08-15"},{"SOURCE_ROW_NUMBER":"74569","DOCUMENT_NO":"220082140039","ACCIDENT_DT":"07/25/2008","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred 1 break inby spad #107 in the return airway. The fall measured 15' wide, 40' long and 4' thick. Persons, equipment nor vetilation were affected.","sourceDate":"2008-07-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-05-15","lastDate":"2012-05-15","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":315,"firstDate":"2006-08-28","lastDate":"2011-09-01","metrics":{"ss":140,"delinquent":314,"recentRows":0,"paidPenalty":158859,"proposedPenalty":186882,"currentAssessment":159003},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1064085","VIOLATION_NO":"8248450","ISSUE_DT":"09/01/2011","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-09-01"},{"SOURCE_ROW_NUMBER":"1064084","VIOLATION_NO":"8248449","ISSUE_DT":"08/30/2011","CFR_STANDARD_CD":"75.202","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1094.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"1064083","VIOLATION_NO":"8248448","ISSUE_DT":"08/30/2011","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"1064082","VIOLATION_NO":"8248447","ISSUE_DT":"08/30/2011","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"1063563","VIOLATION_NO":"8247875","ISSUE_DT":"05/18/2011","CFR_STANDARD_CD":"75.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-05-18"},{"SOURCE_ROW_NUMBER":"1058665","VIOLATION_NO":"8257370","ISSUE_DT":"05/10/2011","CFR_STANDARD_CD":"75.220(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"362.00","CURRENT_ASSESSMENT_AMT":"362.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-05-10"},{"SOURCE_ROW_NUMBER":"1063562","VIOLATION_NO":"8247870","ISSUE_DT":"04/12/2011","CFR_STANDARD_CD":"75.1722(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-04-12"},{"SOURCE_ROW_NUMBER":"1063553","VIOLATION_NO":"8247856","ISSUE_DT":"03/04/2011","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-03-04"},{"SOURCE_ROW_NUMBER":"1063552","VIOLATION_NO":"8247853","ISSUE_DT":"02/23/2011","CFR_STANDARD_CD":"75.214(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-02-23"},{"SOURCE_ROW_NUMBER":"1063551","VIOLATION_NO":"8247852","ISSUE_DT":"02/23/2011","CFR_STANDARD_CD":"75.333(e)(1)(ii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-02-23"},{"SOURCE_ROW_NUMBER":"1063561","VIOLATION_NO":"8247848","ISSUE_DT":"02/11/2011","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-02-11"},{"SOURCE_ROW_NUMBER":"1063550","VIOLATION_NO":"8247847","ISSUE_DT":"02/09/2011","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"425.00","CURRENT_ASSESSMENT_AMT":"425.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2011-02-09"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":40,"firstDate":"2010-11-24","lastDate":"2012-10-26","metrics":{"appeals":0,"decisions":40,"recentRows":0,"decisionPenalty":72068,"originalPenalty":99947},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"79264","VIOLATION_NO":"8248449","DOCKET_NO":"KENT 2012-191","DECISION_DT":"10/26/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1094.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-10-26"},{"SOURCE_ROW_NUMBER":"67741","VIOLATION_NO":"8247709","DOCKET_NO":"KENT 2012-68","DECISION_DT":"10/24/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"655.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-10-24"},{"SOURCE_ROW_NUMBER":"32760","VIOLATION_NO":"8221247","DOCKET_NO":"KENT 2009-639","DECISION_DT":"07/09/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"10437.00","DECISION_PENALTY_AMT":"7000.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2012-07-09"},{"SOURCE_ROW_NUMBER":"233094","VIOLATION_NO":"8216696","DOCKET_NO":"KENT 2009-342","DECISION_DT":"01/04/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"233093","VIOLATION_NO":"8216695","DOCKET_NO":"KENT 2009-342","DECISION_DT":"01/04/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"232951","VIOLATION_NO":"8216693","DOCKET_NO":"KENT 2009-342","DECISION_DT":"01/04/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1795.00","DECISION_PENALTY_AMT":"890.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"232691","VIOLATION_NO":"8216698","DOCKET_NO":"KENT 2009-342","DECISION_DT":"01/04/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"540.00","DECISION_PENALTY_AMT":"540.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"232690","VIOLATION_NO":"7440224","DOCKET_NO":"KENT 2009-342","DECISION_DT":"01/04/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"405.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"31257","VIOLATION_NO":"8216694","DOCKET_NO":"KENT 2009-342","DECISION_DT":"01/04/2012","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"585.00","DECISION_PENALTY_AMT":"585.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2012-01-04"},{"SOURCE_ROW_NUMBER":"235396","VIOLATION_NO":"8221246","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4762.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2011-08-11"},{"SOURCE_ROW_NUMBER":"235395","VIOLATION_NO":"8221245","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"645.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2011-08-11"},{"SOURCE_ROW_NUMBER":"235394","VIOLATION_NO":"8221243","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4500.00","JUDGE_FIRST_NAME":"L","JUDGE_LAST_NAME":"Gill","sourceDate":"2011-08-11"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":415,"firstDate":"2006-09-08","lastDate":"2011-10-05","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":88,"validSamples":327,"maxConcentration":3.264,"concentrationTotal":200.39},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1658236","CASS_NUM":"57899046","SMP_TAKEN_DT":"10/5/2011","CONC":".241","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"1560781","CASS_NUM":"57899097","SMP_TAKEN_DT":"10/5/2011","CONC":".271","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"1501925","CASS_NUM":"57899076","SMP_TAKEN_DT":"10/5/2011","CONC":".546","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"951379","CASS_NUM":"57899018","SMP_TAKEN_DT":"10/5/2011","CONC":".198","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"340786","CASS_NUM":"57899056","SMP_TAKEN_DT":"10/5/2011","CONC":".485","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"327831","CASS_NUM":"57899107","SMP_TAKEN_DT":"10/5/2011","CONC":".376","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"243356","CASS_NUM":"57899072","SMP_TAKEN_DT":"10/5/2011","CONC":".171","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"102477","CASS_NUM":"57899032","SMP_TAKEN_DT":"10/5/2011","CONC":".549","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SUPERINTENDENT","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"70792","CASS_NUM":"57899067","SMP_TAKEN_DT":"10/5/2011","CONC":".255","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"1665942","CASS_NUM":"51115651","SMP_TAKEN_DT":"9/13/2011","CONC":".182","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-13"},{"SOURCE_ROW_NUMBER":"1378578","CASS_NUM":"51115674","SMP_TAKEN_DT":"9/12/2011","CONC":".848","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-12"},{"SOURCE_ROW_NUMBER":"467344","CASS_NUM":"51116333","SMP_TAKEN_DT":"9/10/2011","CONC":".23","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"PREDATED","OCC_CD_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-09-10"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":6,"firstDate":"2006-10-19","lastDate":"2008-11-26","metrics":{"linkedIssuances":6},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":40,"firstDate":"2008-08-06","lastDate":"2011-08-30","metrics":{"decisions":40,"ssChanged":2,"recentRows":0,"decisionPenalty":72068,"proposedPenalty":99947},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"249512","CITATION_NO":"8248449","CITATION_ISSUE_DT":"08/30/2011","DOCKET_NO":"KENT 2012-191","DECISION_DT":"10/26/2012","CFR_STANDARD_CODE":"75.202","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1412.00","DECISION_PENALTY_AMT":"1094.00","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"134223","CITATION_NO":"8247709","CITATION_ISSUE_DT":"11/04/2010","DOCKET_NO":"KENT 2012-68","DECISION_DT":"10/24/2012","CFR_STANDARD_CODE":"77.1605(k)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"873.00","DECISION_PENALTY_AMT":"655.00","sourceDate":"2010-11-04"},{"SOURCE_ROW_NUMBER":"361766","CITATION_NO":"8247447","CITATION_ISSUE_DT":"08/19/2010","DOCKET_NO":"KENT 2011-233","DECISION_DT":"06/29/2011","CFR_STANDARD_CODE":"75.380(d)(7)(iv)","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"319.00","sourceDate":"2010-08-19"},{"SOURCE_ROW_NUMBER":"409428","CITATION_NO":"8220992","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","CFR_STANDARD_CODE":"75.1100-3","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1600.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"408639","CITATION_NO":"8216848","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","CFR_STANDARD_CODE":"75.1103-11","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"2106.00","DECISION_PENALTY_AMT":"1685.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"408562","CITATION_NO":"8219435","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"1111.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"353754","CITATION_NO":"8216849","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-449","DECISION_DT":"11/24/2010","CFR_STANDARD_CODE":"75.515","ORIGINAL_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"108.00","DECISION_PENALTY_AMT":".00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"351644","CITATION_NO":"8221243","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4500.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"295152","CITATION_NO":"8221247","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-639","DECISION_DT":"07/09/2012","CFR_STANDARD_CODE":"75.362(b)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"10437.00","DECISION_PENALTY_AMT":"7000.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"239839","CITATION_NO":"8221244","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","CFR_STANDARD_CODE":"75.512","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"807.00","DECISION_PENALTY_AMT":"807.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"239439","CITATION_NO":"8221246","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"6458.00","DECISION_PENALTY_AMT":"4762.00","sourceDate":"2008-10-31"},{"SOURCE_ROW_NUMBER":"238643","CITATION_NO":"8220679","CITATION_ISSUE_DT":"10/31/2008","DOCKET_NO":"KENT 2009-448","DECISION_DT":"08/11/2011","CFR_STANDARD_CODE":"75.1725(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"3143.00","DECISION_PENALTY_AMT":"2000.00","sourceDate":"2008-10-31"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":419,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":4,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":56,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":3,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2006-01-31","lastDate":"2006-01-31","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":58,"firstDate":"2006-03-15","lastDate":"2012-04-06","metrics":{"inspectors":125,"recentRows":0,"onSiteHours":2315.25,"inspectionHours":3519.25,"inspectionSamples":391},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"209351","EVENT_NO":"4200862","INSPECTION_BEGIN_DT":"04/06/2012","INSPECTION_END_DT":"05/15/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2012-04-06"},{"SOURCE_ROW_NUMBER":"500289","EVENT_NO":"6389081","INSPECTION_BEGIN_DT":"03/02/2012","INSPECTION_END_DT":"03/02/2012","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2012-03-02"},{"SOURCE_ROW_NUMBER":"327387","EVENT_NO":"4200823","INSPECTION_BEGIN_DT":"01/24/2012","INSPECTION_END_DT":"03/26/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2012-01-24"},{"SOURCE_ROW_NUMBER":"492953","EVENT_NO":"4200814","INSPECTION_BEGIN_DT":"10/03/2011","INSPECTION_END_DT":"11/09/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"39.5","SUM_TOTAL_ON_SITE_HOURS":"22.75","sourceDate":"2011-10-03"},{"SOURCE_ROW_NUMBER":"390776","EVENT_NO":"4199806","INSPECTION_BEGIN_DT":"09/14/2011","INSPECTION_END_DT":"09/14/2011","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2011-09-14"},{"SOURCE_ROW_NUMBER":"1016009","EVENT_NO":"4199400","INSPECTION_BEGIN_DT":"08/08/2011","INSPECTION_END_DT":"08/08/2011","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2011-08-08"},{"SOURCE_ROW_NUMBER":"923403","EVENT_NO":"4200811","INSPECTION_BEGIN_DT":"07/11/2011","INSPECTION_END_DT":"09/16/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"107.5","SUM_TOTAL_ON_SITE_HOURS":"75.25","sourceDate":"2011-07-11"},{"SOURCE_ROW_NUMBER":"386421","EVENT_NO":"4199367","INSPECTION_BEGIN_DT":"05/10/2011","INSPECTION_END_DT":"05/16/2011","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2011-05-10"},{"SOURCE_ROW_NUMBER":"800556","EVENT_NO":"4200489","INSPECTION_BEGIN_DT":"04/05/2011","INSPECTION_END_DT":"06/30/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"157.5","SUM_TOTAL_ON_SITE_HOURS":"110.5","sourceDate":"2011-04-05"},{"SOURCE_ROW_NUMBER":"593396","EVENT_NO":"4198899","INSPECTION_BEGIN_DT":"03/29/2011","INSPECTION_END_DT":"04/05/2011","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"19","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2011-03-29"},{"SOURCE_ROW_NUMBER":"550844","EVENT_NO":"4200488","INSPECTION_BEGIN_DT":"02/11/2011","INSPECTION_END_DT":"02/15/2011","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2011-02-11"},{"SOURCE_ROW_NUMBER":"604659","EVENT_NO":"4200486","INSPECTION_BEGIN_DT":"01/04/2011","INSPECTION_END_DT":"03/31/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"138","SUM_TOTAL_ON_SITE_HOURS":"101","sourceDate":"2011-01-04"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":100,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q1":{"hours":0,"employees":0,"production":0},"2011-Q4":{"hours":5197,"employees":11,"production":14992},"2011-Q3":{"hours":20590,"employees":30,"production":44473},"2011-Q2":{"hours":22322,"employees":30,"production":54645},"2011-Q1":{"hours":23856,"employees":29,"production":40089},"2010-Q4":{"hours":21548,"employees":40,"production":36183},"2010-Q3":{"hours":22627,"employees":40,"production":32203},"2010-Q2":{"hours":13016,"employees":24,"production":5793},"2010-Q1":{"hours":171,"employees":1,"production":0},"2009-Q4":{"hours":0,"employees":0,"production":0},"2009-Q3":{"hours":0,"employees":0,"production":0},"2009-Q2":{"hours":2464,"employees":4,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":17,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":40149,"employees":47,"production":151618},"2007":{"hours":145144,"employees":57,"production":362493},"2008":{"hours":105735,"employees":42,"production":208465},"2009":{"hours":5121,"employees":5,"production":0},"2010":{"hours":57362,"employees":35,"production":74179},"2011":{"hours":71965,"employees":26,"production":154199}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":51,"firstDate":"2006-09-26","lastDate":"2011-10-05","metrics":{"recentRows":0,"doseOver100":5,"actDoseTotal":2952,"pelDoseTotal":2000},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"91150","EVENT_NO":"4200814","SURVEY_DATE":"10/05/2011","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"30","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"91149","EVENT_NO":"4200814","SURVEY_DATE":"10/05/2011","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"19","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"91148","EVENT_NO":"4200814","SURVEY_DATE":"10/05/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"102","PEL_DOSE_90":"93","SURVEY_TYPE":"I","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"91147","EVENT_NO":"4200814","SURVEY_DATE":"10/05/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"29","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"91146","EVENT_NO":"4200814","SURVEY_DATE":"10/05/2011","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"54","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"91145","EVENT_NO":"4200814","SURVEY_DATE":"10/05/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"038","ACT_DOSE_85":"28","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"91144","EVENT_NO":"4200814","SURVEY_DATE":"10/05/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"61","PEL_DOSE_90":"30","SURVEY_TYPE":"I","sourceDate":"2011-10-05"},{"SOURCE_ROW_NUMBER":"91143","EVENT_NO":"4200483","SURVEY_DATE":"10/20/2010","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"8","PEL_DOSE_90":"2","SURVEY_TYPE":"I","sourceDate":"2010-10-20"},{"SOURCE_ROW_NUMBER":"91142","EVENT_NO":"4200483","SURVEY_DATE":"10/20/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"63","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2010-10-20"},{"SOURCE_ROW_NUMBER":"91141","EVENT_NO":"4200483","SURVEY_DATE":"10/20/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"43","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2010-10-20"},{"SOURCE_ROW_NUMBER":"91140","EVENT_NO":"4200483","SURVEY_DATE":"10/20/2010","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"40","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2010-10-20"},{"SOURCE_ROW_NUMBER":"91139","EVENT_NO":"4200483","SURVEY_DATE":"10/20/2010","OCCUPATION_CD_DESC":"AUGER (TIMBERMAN) (INTAKE SIDE)","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"30","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2010-10-20"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":35,"firstDate":"2006-10-19","lastDate":"2011-09-07","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":18.9,"validSamples":32,"quartzPctTotal":189.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"156920","CASSETTE_NO":"51115670","SAMPLE_DT":"09/07/2011","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-09-07"},{"SOURCE_ROW_NUMBER":"81258","CASSETTE_NO":"51098244","SAMPLE_DT":"01/31/2011","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"38114","CASSETTE_NO":"51098247","SAMPLE_DT":"01/31/2011","QUARTZ_PCT":"02.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"151937","CASSETTE_NO":"57899643","SAMPLE_DT":"01/11/2011","QUARTZ_PCT":"01.4","OCC_CODE_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-11"},{"SOURCE_ROW_NUMBER":"88558","CASSETTE_NO":"57899685","SAMPLE_DT":"01/11/2011","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-11"},{"SOURCE_ROW_NUMBER":"5877","CASSETTE_NO":"57899677","SAMPLE_DT":"01/11/2011","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-11"},{"SOURCE_ROW_NUMBER":"33169","CASSETTE_NO":"57899907","SAMPLE_DT":"10/20/2010","QUARTZ_PCT":"01.3","OCC_CODE_DESC":"BULLGANG FOREMAN/LABOR FOREMAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-10-20"},{"SOURCE_ROW_NUMBER":"164720","CASSETTE_NO":"51016851","SAMPLE_DT":"09/15/2010","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2010-09-15"},{"SOURCE_ROW_NUMBER":"66730","CASSETTE_NO":"57852785","SAMPLE_DT":"08/19/2010","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-08-19"},{"SOURCE_ROW_NUMBER":"60576","CASSETTE_NO":"57852786","SAMPLE_DT":"08/19/2010","QUARTZ_PCT":"10.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-08-19"},{"SOURCE_ROW_NUMBER":"70568","CASSETTE_NO":"50954415","SAMPLE_DT":"10/27/2008","QUARTZ_PCT":"16.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-10-27"},{"SOURCE_ROW_NUMBER":"59391","CASSETTE_NO":"57692696","SAMPLE_DT":"05/28/2008","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2008-05-28"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":330,"firstDate":"2006-08-28","lastDate":"2011-09-01","metrics":{"ss":140,"amountDue":159003,"contested":38,"amountPaid":158859,"recentRows":0,"section104d":2,"unterminated":4,"proposedPenalty":186882},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1093842","VIOLATION_NO":"8248450","VIOLATION_ISSUE_DT":"09/01/2011","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/01/2011","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2011-09-01"},{"SOURCE_ROW_NUMBER":"1093841","VIOLATION_NO":"8248449","VIOLATION_ISSUE_DT":"08/30/2011","SIG_SUB":"Y","PART_SECTION":"75.202","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/31/2011","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1094","AMOUNT_PAID":"1094","CONTESTED_IND":"N","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"1093840","VIOLATION_NO":"8248448","VIOLATION_ISSUE_DT":"08/30/2011","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/31/2011","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"1093839","VIOLATION_NO":"8248447","VIOLATION_ISSUE_DT":"08/30/2011","SIG_SUB":"N","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/31/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-08-30"},{"SOURCE_ROW_NUMBER":"1093773","VIOLATION_NO":"8247875","VIOLATION_ISSUE_DT":"05/18/2011","SIG_SUB":"Y","PART_SECTION":"75.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/18/2011","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2011-05-18"},{"SOURCE_ROW_NUMBER":"1093789","VIOLATION_NO":"8257370","VIOLATION_ISSUE_DT":"05/10/2011","SIG_SUB":"Y","PART_SECTION":"75.220(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/10/2011","PROPOSED_PENALTY":"362","AMOUNT_DUE":"362","AMOUNT_PAID":"362","CONTESTED_IND":"N","sourceDate":"2011-05-10"},{"SOURCE_ROW_NUMBER":"1093772","VIOLATION_NO":"8247870","VIOLATION_ISSUE_DT":"04/12/2011","SIG_SUB":"Y","PART_SECTION":"75.1722(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/12/2011","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2011-04-12"},{"SOURCE_ROW_NUMBER":"1093701","VIOLATION_NO":"8247856","VIOLATION_ISSUE_DT":"03/04/2011","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/04/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-03-04"},{"SOURCE_ROW_NUMBER":"1093700","VIOLATION_NO":"8247853","VIOLATION_ISSUE_DT":"02/23/2011","SIG_SUB":"N","PART_SECTION":"75.214(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/23/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-02-23"},{"SOURCE_ROW_NUMBER":"1093699","VIOLATION_NO":"8247852","VIOLATION_ISSUE_DT":"02/23/2011","SIG_SUB":"N","PART_SECTION":"75.333(e)(1)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/23/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-02-23"},{"SOURCE_ROW_NUMBER":"1093722","VIOLATION_NO":"8247848","VIOLATION_ISSUE_DT":"02/11/2011","SIG_SUB":"N","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/11/2011","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2011-02-11"},{"SOURCE_ROW_NUMBER":"1093698","VIOLATION_NO":"8247847","VIOLATION_ISSUE_DT":"02/09/2011","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/09/2011","PROPOSED_PENALTY":"425","AMOUNT_DUE":"425","AMOUNT_PAID":"425","CONTESTED_IND":"N","sourceDate":"2011-02-09"}]}],"safety":{"href":"/api/v1/mines/1518964/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518964/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.701","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","id":"75.701","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-H/section-75.701","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"H","subpartHeading":"Subpart H—Grounding","text":"[Statutory Provisions]\n\nMetallic frames, casings, and other enclosures of electric equipment that can become “alive” through failure of insulation or by contact with energized parts shall be grounded by methods approved by an authorized representative of the Secretary.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.220","heading":"Roof control plan.","id":"75.220","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.220","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.\n\n(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager.\n\n(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.\n\n(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revision and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.\n\n(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.\n\n(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.\n\n(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.\n\n(e) The approved roof control plan and any revisions shall be available to the miners and representative of miners at the mine.\n\n[53 FR 2375, Jan. 27, 1988; 53 FR 11395, Apr. 6, 1988, as amended at 60 FR 33723, June 29, 1995; 71 FR 16668, Apr. 3, 2006]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","heading":"Supplemental support materials, equipment and tools.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.214","part":"75","subchapter":"O","subpart":"C","id":"75.214","citation":"30 CFR 75.214","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518964","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}