{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518881","name":"#9","status":"Abandoned and Sealed","status_date":"2015-03-12","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Dana","operator_id":"0060024","operator_name":"Cheyenne Enterprises Inc","controller_id":"0142565","controller_name":"Greg  Damron","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.56,"longitude":-82.675},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":2027},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518881","name":"#9"},"operator":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc"},"controller":{"type":"controller","id":"0142565","name":"Greg  Damron"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc"},"object":{"type":"mine","id":"1518881","name":"#9"},"validFrom":"2005-05-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518881|0060024|2005-05-26|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0050011","name":"Greg  Damron  et al"},"object":{"type":"mine","id":"1518881","name":"#9"},"validFrom":"2005-05-26","validTo":"2018-08-12","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518881|0050011|2005-05-26|2018-08-12"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0050011","name":"Greg  Damron  et al"},"object":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc"},"validFrom":"2005-05-26","validTo":"2018-08-12","current":false,"derived":true,"evidenceMineId":"1518881","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518881|0060024|2005-05-26|0050011|2005-05-26|6261"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0050011","name":"Henry  Chaney  et al"},"object":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc"},"validFrom":"2005-05-26","validTo":"2018-08-12","current":false,"derived":true,"evidenceMineId":"1518881","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518881|0060024|2005-05-26|0050011|2005-05-26|6262"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0142565","name":"Greg  Damron"},"object":{"type":"mine","id":"1518881","name":"#9"},"validFrom":"2018-08-13","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518881|0142565|2018-08-13|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0142565","name":"Greg  Damron"},"object":{"type":"operator","id":"0060024","name":"Cheyenne Enterprises Inc"},"validFrom":"2018-08-13","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518881","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518881|0060024|2005-05-26|0142565|2018-08-13|28913"}}],"coverage":{"historyRecords":3,"edgeCount":6,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":2,"firstDate":"2010-06-28","lastDate":"2013-08-15","metrics":{"daysLost":0,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"74559","DOCUMENT_NO":"220132410045","ACCIDENT_DT":"08/15/2013","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Roof bolting and piece of drill steel struck above eye.","sourceDate":"2013-08-15"},{"SOURCE_ROW_NUMBER":"125967","DOCUMENT_NO":"220101810003","ACCIDENT_DT":"06/28/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"5 breaks inby portal. Roof fall 3'5\" h x 8' w x 40\" l.  Fell between bolts in an area of a hillseam.  Roof is solid sandstone and this was a hillseam.","sourceDate":"2010-06-28"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2015-03-12","lastDate":"2015-03-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":416,"firstDate":"2005-08-11","lastDate":"2014-06-27","metrics":{"ss":105,"delinquent":416,"recentRows":0,"paidPenalty":75106,"proposedPenalty":76319,"currentAssessment":75106},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1951765","VIOLATION_NO":"4479175","ISSUE_DT":"06/27/2014","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-06-27"},{"SOURCE_ROW_NUMBER":"1952182","VIOLATION_NO":"8292775","ISSUE_DT":"03/05/2014","CFR_STANDARD_CD":"77.1110","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"1952181","VIOLATION_NO":"8292774","ISSUE_DT":"02/19/2014","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"1952180","VIOLATION_NO":"8292773","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952179","VIOLATION_NO":"8292772","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.362(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"807.00","CURRENT_ASSESSMENT_AMT":"807.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952178","VIOLATION_NO":"8292771","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952177","VIOLATION_NO":"8292770","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.1731(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952176","VIOLATION_NO":"8292769","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.1731(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952175","VIOLATION_NO":"8292768","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.1100-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"162.00","CURRENT_ASSESSMENT_AMT":"162.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952174","VIOLATION_NO":"8292767","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952173","VIOLATION_NO":"8292766","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"807.00","CURRENT_ASSESSMENT_AMT":"807.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1952172","VIOLATION_NO":"8292765","ISSUE_DT":"01/28/2014","CFR_STANDARD_CD":"77.400(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2014-01-28"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":6,"firstDate":"2012-10-22","lastDate":"2014-07-23","metrics":{"appeals":0,"decisions":6,"recentRows":0,"decisionPenalty":3374,"originalPenalty":4587},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"351647","VIOLATION_NO":"8292127","DOCKET_NO":"KENT 2014-51","DECISION_DT":"07/23/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"110.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2014-07-23"},{"SOURCE_ROW_NUMBER":"351646","VIOLATION_NO":"8292118","DOCKET_NO":"KENT 2014-51","DECISION_DT":"07/23/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2014-07-23"},{"SOURCE_ROW_NUMBER":"350802","VIOLATION_NO":"8292123","DOCKET_NO":"KENT 2014-51","DECISION_DT":"07/23/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"284.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2014-07-23"},{"SOURCE_ROW_NUMBER":"328892","VIOLATION_NO":"8274500","DOCKET_NO":"KENT 2012-1434","DECISION_DT":"01/30/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"249.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2013-01-30"},{"SOURCE_ROW_NUMBER":"328657","VIOLATION_NO":"8274503","DOCKET_NO":"KENT 2012-1434","DECISION_DT":"01/30/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Simonton","sourceDate":"2013-01-30"},{"SOURCE_ROW_NUMBER":"311013","VIOLATION_NO":"8246211","DOCKET_NO":"KENT 2012-101","DECISION_DT":"10/22/2012","DECISION_TYPE_CODE_DESC":"Default","ORIGINAL_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1944.00","JUDGE_FIRST_NAME":"Robert","JUDGE_LAST_NAME":"Lesnick","sourceDate":"2012-10-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":652,"firstDate":"2005-01-06","lastDate":"2014-03-10","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":78,"validSamples":574,"maxConcentration":9.892,"concentrationTotal":547.726},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1166320","CASS_NUM":"57943039","SMP_TAKEN_DT":"3/10/2014","CONC":"1.181","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"1158216","CASS_NUM":"57943341","SMP_TAKEN_DT":"3/10/2014","CONC":"1.798","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"683246","CASS_NUM":"57943030","SMP_TAKEN_DT":"3/10/2014","CONC":"1.766","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"470845","CASS_NUM":"57943154","SMP_TAKEN_DT":"3/10/2014","CONC":".52","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"291737","CASS_NUM":"57943244","SMP_TAKEN_DT":"3/10/2014","CONC":".132","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"75710","CASS_NUM":"57943343","SMP_TAKEN_DT":"3/10/2014","CONC":"1.335","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"1614943","CASS_NUM":"58147818","SMP_TAKEN_DT":"2/19/2014","CONC":".547","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"1463958","CASS_NUM":"58147936","SMP_TAKEN_DT":"2/19/2014","CONC":".064","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"1428621","CASS_NUM":"58147825","SMP_TAKEN_DT":"2/19/2014","CONC":"1.02","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"1153646","CASS_NUM":"58147947","SMP_TAKEN_DT":"2/19/2014","CONC":".201","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"1047807","CASS_NUM":"58147950","SMP_TAKEN_DT":"2/19/2014","CONC":".393","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"608848","CASS_NUM":"58147958","SMP_TAKEN_DT":"2/19/2014","CONC":"1.947","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2014-02-19"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2013-08-16","lastDate":"2013-08-16","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":6,"firstDate":"2011-08-08","lastDate":"2013-09-18","metrics":{"decisions":6,"ssChanged":2,"recentRows":0,"decisionPenalty":3374,"proposedPenalty":4587},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"370003","CITATION_NO":"8292127","CITATION_ISSUE_DT":"09/18/2013","DOCKET_NO":"KENT 2014-51","DECISION_DT":"07/23/2014","CFR_STANDARD_CODE":"75.1403","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"285.00","DECISION_PENALTY_AMT":"110.00","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"370002","CITATION_NO":"8292123","CITATION_ISSUE_DT":"08/14/2013","DOCKET_NO":"KENT 2014-51","DECISION_DT":"07/23/2014","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"N","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"460.00","DECISION_PENALTY_AMT":"284.00","sourceDate":"2013-08-14"},{"SOURCE_ROW_NUMBER":"369973","CITATION_NO":"8292118","CITATION_ISSUE_DT":"08/08/2013","DOCKET_NO":"KENT 2014-51","DECISION_DT":"07/23/2014","CFR_STANDARD_CODE":"75.1722(c)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"425.00","DECISION_PENALTY_AMT":"425.00","sourceDate":"2013-08-08"},{"SOURCE_ROW_NUMBER":"256101","CITATION_NO":"8274503","CITATION_ISSUE_DT":"05/14/2012","DOCKET_NO":"KENT 2012-1434","DECISION_DT":"01/30/2013","CFR_STANDARD_CODE":"75.1720(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"362.00","DECISION_PENALTY_AMT":"362.00","sourceDate":"2012-05-14"},{"SOURCE_ROW_NUMBER":"28936","CITATION_NO":"8274500","CITATION_ISSUE_DT":"05/14/2012","DOCKET_NO":"KENT 2012-1434","DECISION_DT":"01/30/2013","CFR_STANDARD_CODE":"75.400","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1111.00","DECISION_PENALTY_AMT":"249.00","sourceDate":"2012-05-14"},{"SOURCE_ROW_NUMBER":"199622","CITATION_NO":"8246211","CITATION_ISSUE_DT":"08/08/2011","DOCKET_NO":"KENT 2012-101","DECISION_DT":"10/22/2012","CFR_STANDARD_CODE":"75.360(b)(3)","ORIGINAL_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1944.00","DECISION_PENALTY_AMT":"1944.00","sourceDate":"2011-08-08"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":153,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":29,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2005-05-26","lastDate":"2005-05-26","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":92,"firstDate":"2005-06-02","lastDate":"2014-12-17","metrics":{"inspectors":178,"recentRows":0,"onSiteHours":3807.75,"inspectionHours":5480,"inspectionSamples":610},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1001993","EVENT_NO":"6390324","INSPECTION_BEGIN_DT":"12/17/2014","INSPECTION_END_DT":"03/12/2015","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"23.5","SUM_TOTAL_ON_SITE_HOURS":"11.5","sourceDate":"2014-12-17"},{"SOURCE_ROW_NUMBER":"87592","EVENT_NO":"6389142","INSPECTION_BEGIN_DT":"07/01/2014","INSPECTION_END_DT":"07/01/2014","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2014-07-01"},{"SOURCE_ROW_NUMBER":"901704","EVENT_NO":"6390118","INSPECTION_BEGIN_DT":"04/02/2014","INSPECTION_END_DT":"06/27/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"36.5","SUM_TOTAL_ON_SITE_HOURS":"14.5","sourceDate":"2014-04-02"},{"SOURCE_ROW_NUMBER":"521430","EVENT_NO":"4204215","INSPECTION_BEGIN_DT":"02/05/2014","INSPECTION_END_DT":"02/07/2014","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20.5","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2014-02-05"},{"SOURCE_ROW_NUMBER":"674658","EVENT_NO":"6390301","INSPECTION_BEGIN_DT":"01/07/2014","INSPECTION_END_DT":"03/19/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"207","SUM_TOTAL_ON_SITE_HOURS":"151.5","sourceDate":"2014-01-07"},{"SOURCE_ROW_NUMBER":"563477","EVENT_NO":"6393556","INSPECTION_BEGIN_DT":"12/30/2013","INSPECTION_END_DT":"12/30/2013","ACTIVITY_CODE":"E21","ACTIVITY":"Ventilation Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2013-12-30"},{"SOURCE_ROW_NUMBER":"927679","EVENT_NO":"4203545","INSPECTION_BEGIN_DT":"10/18/2013","INSPECTION_END_DT":"12/23/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"170","SUM_TOTAL_ON_SITE_HOURS":"123","sourceDate":"2013-10-18"},{"SOURCE_ROW_NUMBER":"859578","EVENT_NO":"6389854","INSPECTION_BEGIN_DT":"10/15/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"35","SUM_TOTAL_ON_SITE_HOURS":"23","sourceDate":"2013-10-15"},{"SOURCE_ROW_NUMBER":"220878","EVENT_NO":"4204131","INSPECTION_BEGIN_DT":"10/11/2013","INSPECTION_END_DT":"10/11/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7.5","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2013-10-11"},{"SOURCE_ROW_NUMBER":"728848","EVENT_NO":"4203543","INSPECTION_BEGIN_DT":"10/07/2013","INSPECTION_END_DT":"10/17/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"48.5","SUM_TOTAL_ON_SITE_HOURS":"35","sourceDate":"2013-10-07"},{"SOURCE_ROW_NUMBER":"514233","EVENT_NO":"6389183","INSPECTION_BEGIN_DT":"10/07/2013","INSPECTION_END_DT":"10/09/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"7","sourceDate":"2013-10-07"},{"SOURCE_ROW_NUMBER":"756884","EVENT_NO":"6392919","INSPECTION_BEGIN_DT":"10/02/2013","INSPECTION_END_DT":"10/02/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2013-10-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":108,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2014-Q2":{"hours":2823,"employees":15,"production":0},"2014-Q1":{"hours":10983,"employees":18,"production":21466},"2013-Q4":{"hours":13408,"employees":21,"production":21220},"2013-Q3":{"hours":13812,"employees":20,"production":20526},"2013-Q2":{"hours":13579,"employees":20,"production":25384},"2013-Q1":{"hours":13189,"employees":19,"production":29727},"2012-Q4":{"hours":11701,"employees":19,"production":30671},"2012-Q3":{"hours":10622,"employees":18,"production":25261},"2012-Q2":{"hours":12410,"employees":21,"production":27594},"2012-Q1":{"hours":11335,"employees":21,"production":29378},"2011-Q4":{"hours":11577,"employees":21,"production":20281},"2011-Q3":{"hours":11639,"employees":21,"production":25107}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":30,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":16744,"employees":19,"production":51699},"2006":{"hours":40084,"employees":18,"production":138949},"2007":{"hours":44826,"employees":18,"production":127489},"2008":{"hours":40861,"employees":15,"production":125451},"2009":{"hours":45616,"employees":18,"production":121957},"2010":{"hours":47772,"employees":20,"production":121068},"2011":{"hours":47001,"employees":21,"production":122079},"2012":{"hours":46068,"employees":19,"production":112904},"2013":{"hours":53988,"employees":20,"production":96857},"2014":{"hours":13806,"employees":17,"production":21466}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":56,"firstDate":"2005-08-16","lastDate":"2013-12-11","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":3015,"pelDoseTotal":2159},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"89067","EVENT_NO":"4203545","SURVEY_DATE":"12/11/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"28","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2013-12-11"},{"SOURCE_ROW_NUMBER":"89066","EVENT_NO":"4203545","SURVEY_DATE":"11/07/2013","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"58","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"89065","EVENT_NO":"4203545","SURVEY_DATE":"11/07/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"58","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"89064","EVENT_NO":"4203545","SURVEY_DATE":"11/07/2013","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"63","PEL_DOSE_90":"45","SURVEY_TYPE":"I","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"89063","EVENT_NO":"4203545","SURVEY_DATE":"11/07/2013","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"19","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"89062","EVENT_NO":"4203545","SURVEY_DATE":"11/07/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"11","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"89061","EVENT_NO":"4203545","SURVEY_DATE":"11/07/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"52","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"89060","EVENT_NO":"4203545","SURVEY_DATE":"11/07/2013","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"33","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2013-11-07"},{"SOURCE_ROW_NUMBER":"89084","EVENT_NO":"6389665","SURVEY_DATE":"08/22/2013","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","ACT_DOSE_85":"27","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2013-08-22"},{"SOURCE_ROW_NUMBER":"89083","EVENT_NO":"6389665","SURVEY_DATE":"08/22/2013","OCCUPATION_CD_DESC":"SECTION FOREMAN","ACT_DOSE_85":"19","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2013-08-22"},{"SOURCE_ROW_NUMBER":"89082","EVENT_NO":"6389665","SURVEY_DATE":"08/22/2013","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"60","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2013-08-22"},{"SOURCE_ROW_NUMBER":"89081","EVENT_NO":"6389665","SURVEY_DATE":"08/22/2013","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"44","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2013-08-22"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":45,"firstDate":"2005-08-16","lastDate":"2014-03-10","metrics":{"recentRows":0,"voidSamples":3,"maxQuartzPct":27.9,"validSamples":42,"quartzPctTotal":224.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"39567","CASSETTE_NO":"57943039","SAMPLE_DT":"03/10/2014","QUARTZ_PCT":"03.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-03-10"},{"SOURCE_ROW_NUMBER":"95019","CASSETTE_NO":"58147825","SAMPLE_DT":"02/19/2014","QUARTZ_PCT":"03.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"121401","CASSETTE_NO":"58116024","SAMPLE_DT":"10/30/2013","QUARTZ_PCT":"09.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-10-30"},{"SOURCE_ROW_NUMBER":"165237","CASSETTE_NO":"58104905","SAMPLE_DT":"09/18/2013","QUARTZ_PCT":"09.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-09-18"},{"SOURCE_ROW_NUMBER":"160633","CASSETTE_NO":"58104640","SAMPLE_DT":"09/03/2013","QUARTZ_PCT":"11.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-09-03"},{"SOURCE_ROW_NUMBER":"56064","CASSETTE_NO":"58104673","SAMPLE_DT":"09/03/2013","QUARTZ_PCT":"09.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-09-03"},{"SOURCE_ROW_NUMBER":"51355","CASSETTE_NO":"51195382","SAMPLE_DT":"05/17/2013","QUARTZ_PCT":"00.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-05-17"},{"SOURCE_ROW_NUMBER":"148811","CASSETTE_NO":"51195757","SAMPLE_DT":"04/23/2013","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"CONTAMINATED","sourceDate":"2013-04-23"},{"SOURCE_ROW_NUMBER":"119401","CASSETTE_NO":"51195389","SAMPLE_DT":"04/23/2013","QUARTZ_PCT":"06.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-04-23"},{"SOURCE_ROW_NUMBER":"121604","CASSETTE_NO":"57978983","SAMPLE_DT":"03/26/2013","QUARTZ_PCT":"27.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-03-26"},{"SOURCE_ROW_NUMBER":"26513","CASSETTE_NO":"57978955","SAMPLE_DT":"03/26/2013","QUARTZ_PCT":"10.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2013-03-26"},{"SOURCE_ROW_NUMBER":"144169","CASSETTE_NO":"51163183","SAMPLE_DT":"12/21/2012","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2012-12-21"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":426,"firstDate":"2005-08-11","lastDate":"2014-06-27","metrics":{"ss":105,"amountDue":75106,"contested":0,"amountPaid":75106,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":76319},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1081868","VIOLATION_NO":"4479175","VIOLATION_ISSUE_DT":"06/27/2014","SIG_SUB":"N","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"07/01/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-06-27"},{"SOURCE_ROW_NUMBER":"1081770","VIOLATION_NO":"8292775","VIOLATION_ISSUE_DT":"03/05/2014","SIG_SUB":"N","PART_SECTION":"77.1110","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/05/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-03-05"},{"SOURCE_ROW_NUMBER":"1081769","VIOLATION_NO":"8292774","VIOLATION_ISSUE_DT":"02/19/2014","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/27/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-02-19"},{"SOURCE_ROW_NUMBER":"1081768","VIOLATION_NO":"8292773","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081767","VIOLATION_NO":"8292772","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"Y","PART_SECTION":"75.362(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"807","AMOUNT_DUE":"807","AMOUNT_PAID":"807","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081766","VIOLATION_NO":"8292771","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081765","VIOLATION_NO":"8292770","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"N","PART_SECTION":"75.1731(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081764","VIOLATION_NO":"8292769","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"N","PART_SECTION":"75.1731(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081763","VIOLATION_NO":"8292768","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"N","PART_SECTION":"75.1100-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"162","AMOUNT_DUE":"162","AMOUNT_PAID":"162","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081762","VIOLATION_NO":"8292767","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"243","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081761","VIOLATION_NO":"8292766","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"807","AMOUNT_DUE":"807","AMOUNT_PAID":"807","CONTESTED_IND":"N","sourceDate":"2014-01-28"},{"SOURCE_ROW_NUMBER":"1081760","VIOLATION_NO":"8292765","VIOLATION_ISSUE_DT":"01/28/2014","SIG_SUB":"N","PART_SECTION":"77.400(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/29/2014","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2014-01-28"}]}],"safety":{"href":"/api/v1/mines/1518881/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518881/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1110","heading":"Examination and maintenance of firefighting equipment.","id":"77.1110","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1110","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment shall be continuously maintained in a usable and operative condition. Fire extinguishers shall be examined at least once every 6 months and the date of such examination shall be recorded on a permanent tag attached to the extinguisher.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1731","heading":"Maintenance of belt conveyors and belt conveyor entries.","id":"75.1731","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1731","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Damaged rollers, or other damaged belt conveyor components, which pose a fire hazard must be immediately repaired or replaced. All other damaged rollers, or other damaged belt conveyor components, must be repaired or replaced.\n\n(b) Conveyor belts must be properly aligned to prevent the moving belt from rubbing against the structure or components.\n\n(c) Materials shall not be allowed in the belt conveyor entry where the material may contribute to a frictional heating hazard.\n\n(d) Splicing of any approved conveyor belt must maintain flame-resistant properties of the belt.\n\n[73 FR 80616, Dec. 31, 2008]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-3","heading":"Condition and examination of firefighting equipment.","id":"75.1100-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.400","heading":"Mechanical equipment guards.","id":"77.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.400","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings; shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Overhead belts shall be guarded if the whipping action from a broken line would be hazardous to persons below.\n\n(c) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(d) Except when testing the machinery, guards shall be securely in place while machinery is being operated.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518881","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}