{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518871","name":"No 7C","status":"Abandoned and Sealed","status_date":"2007-04-25","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Biggs","operator_id":"P22115","operator_name":"Dags Branch Coal Co Inc","controller_id":"0043785","controller_name":"James L  Griffith","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.448888,"longitude":-82.2375},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":262},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518871","name":"No 7C"},"operator":{"type":"operator","id":"P22115","name":"Dags Branch Coal Co Inc"},"controller":{"type":"controller","id":"0043785","name":"James L  Griffith"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14730","name":"Danny  Justice"},"object":{"type":"mine","id":"1518871","name":"No 7C"},"validFrom":"1992-10-19","validTo":"2004-06-30","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|C14730|1992-10-19|2004-06-30"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0043785","name":"James L  Griffith"},"object":{"type":"mine","id":"1518871","name":"No 7C"},"validFrom":"2004-07-01","validTo":"2014-12-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|0043785|2004-07-01|2014-12-31"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P22115","name":"Dags Branch Coal Co Inc"},"object":{"type":"mine","id":"1518871","name":"No 7C"},"validFrom":"2005-05-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|P22115|2005-05-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0043785","name":"James L  Griffith"},"object":{"type":"operator","id":"P22115","name":"Dags Branch Coal Co Inc"},"validFrom":"2005-05-12","validTo":"2014-12-31","current":false,"derived":true,"evidenceMineId":"1518871","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|P22115|2005-05-12|0043785|2004-07-01|4819"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14730","name":"Danny  Justice"},"object":{"type":"operator","id":"P22115","name":"Dags Branch Coal Co Inc"},"validFrom":"2005-05-12","validTo":"2004-06-30","current":false,"derived":true,"evidenceMineId":"1518871","intervalAnomaly":true,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|P22115|2005-05-12|C14730|1992-10-19|93717"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0116543","name":"Herbert R  Hamilton et al"},"object":{"type":"mine","id":"1518871","name":"No 7C"},"validFrom":"2015-01-01","validTo":"2016-05-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|0116543|2015-01-01|2016-05-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0116543","name":"Herbert R  Hamilton et al"},"object":{"type":"operator","id":"P22115","name":"Dags Branch Coal Co Inc"},"validFrom":"2015-01-01","validTo":"2016-05-25","current":false,"derived":true,"evidenceMineId":"1518871","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|P22115|2005-05-12|0116543|2015-01-01|22036"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0116543","name":"James L  Griffith et al"},"object":{"type":"operator","id":"P22115","name":"Dags Branch Coal Co Inc"},"validFrom":"2015-01-01","validTo":"2016-05-25","current":false,"derived":true,"evidenceMineId":"1518871","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|P22115|2005-05-12|0116543|2015-01-01|22037"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0043785","name":"James L  Griffith"},"object":{"type":"mine","id":"1518871","name":"No 7C"},"validFrom":"2016-05-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|0043785|2016-05-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0043785","name":"James L  Griffith"},"object":{"type":"operator","id":"P22115","name":"Dags Branch Coal Co Inc"},"validFrom":"2016-05-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518871","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518871|P22115|2005-05-12|0043785|2016-05-26|4834"}}],"coverage":{"historyRecords":5,"edgeCount":10,"intervalAnomalies":1,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2006-06-13","lastDate":"2006-11-13","metrics":{"daysLost":146,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"251077","DOCUMENT_NO":"220063210040","ACCIDENT_DT":"11/13/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"146","NARRATIVE":"Installing tram motor on a continuous miner, he was prying on the motor with a slate bar.","sourceDate":"2006-11-13"},{"SOURCE_ROW_NUMBER":"272481","DOCUMENT_NO":"220062610063","ACCIDENT_DT":"09/12/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was rockdusting around A2 belt drive when he slipped and fell against the tailpiece hitting on his right side.","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"53124","DOCUMENT_NO":"220061730036","ACCIDENT_DT":"06/13/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall onto or against objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"EE attempted to pull a sumercable pump out of the water when his footage slipped he hit right knee down on a piece of rock.","sourceDate":"2006-06-13"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-04-25","lastDate":"2007-04-25","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":56,"firstDate":"2005-06-07","lastDate":"2006-10-19","metrics":{"ss":19,"delinquent":56,"recentRows":0,"paidPenalty":3955,"proposedPenalty":4087,"currentAssessment":4087},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"980900","VIOLATION_NO":"7438085","ISSUE_DT":"10/19/2006","CFR_STANDARD_CD":"75.1103-8(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"980899","VIOLATION_NO":"7438084","ISSUE_DT":"10/19/2006","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"980898","VIOLATION_NO":"7438083","ISSUE_DT":"10/19/2006","CFR_STANDARD_CD":"75.512-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"980901","VIOLATION_NO":"9881141","ISSUE_DT":"10/11/2006","CFR_STANDARD_CD":"70.208(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-11"},{"SOURCE_ROW_NUMBER":"981402","VIOLATION_NO":"7437853","ISSUE_DT":"09/11/2006","CFR_STANDARD_CD":"75.521","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"981401","VIOLATION_NO":"7437852","ISSUE_DT":"09/11/2006","CFR_STANDARD_CD":"75.1712-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"981406","VIOLATION_NO":"7437976","ISSUE_DT":"08/10/2006","CFR_STANDARD_CD":"75.1100-2(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-08-10"},{"SOURCE_ROW_NUMBER":"981405","VIOLATION_NO":"7437971","ISSUE_DT":"08/01/2006","CFR_STANDARD_CD":"75.1100-2(e)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-08-01"},{"SOURCE_ROW_NUMBER":"981404","VIOLATION_NO":"7437970","ISSUE_DT":"07/28/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-07-28"},{"SOURCE_ROW_NUMBER":"981403","VIOLATION_NO":"7437968","ISSUE_DT":"07/24/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-07-24"},{"SOURCE_ROW_NUMBER":"981378","VIOLATION_NO":"7437966","ISSUE_DT":"06/28/2006","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-28"},{"SOURCE_ROW_NUMBER":"981377","VIOLATION_NO":"7437965","ISSUE_DT":"05/31/2006","CFR_STANDARD_CD":"77.701","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-05-31"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":72,"firstDate":"2005-08-01","lastDate":"2006-10-31","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":3,"validSamples":69,"maxConcentration":2.567,"concentrationTotal":26.469},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"368386","CASS_NUM":"50857212","SMP_TAKEN_DT":"10/31/2006","CONC":".253","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"1263192","CASS_NUM":"50843396","SMP_TAKEN_DT":"10/30/2006","CONC":".677","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"1491402","CASS_NUM":"50843418","SMP_TAKEN_DT":"10/27/2006","CONC":"0","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-27"},{"SOURCE_ROW_NUMBER":"251916","CASS_NUM":"50843442","SMP_TAKEN_DT":"10/26/2006","CONC":".29","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-26"},{"SOURCE_ROW_NUMBER":"787228","CASS_NUM":"50843413","SMP_TAKEN_DT":"10/25/2006","CONC":".303","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-25"},{"SOURCE_ROW_NUMBER":"815819","CASS_NUM":"50843454","SMP_TAKEN_DT":"10/24/2006","CONC":".079","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-24"},{"SOURCE_ROW_NUMBER":"1611694","CASS_NUM":"57634695","SMP_TAKEN_DT":"10/12/2006","CONC":".163","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"1578533","CASS_NUM":"57634671","SMP_TAKEN_DT":"10/12/2006","CONC":".086","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"1140554","CASS_NUM":"57634641","SMP_TAKEN_DT":"10/12/2006","CONC":".033","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"712188","CASS_NUM":"57634696","SMP_TAKEN_DT":"10/12/2006","CONC":".096","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"LABORER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"559292","CASS_NUM":"57634684","SMP_TAKEN_DT":"10/12/2006","CONC":".047","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"293051","CASS_NUM":"57634756","SMP_TAKEN_DT":"10/12/2006","CONC":".345","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-10-12"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2006-05-23","lastDate":"2006-05-23","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":5,"firstDate":"2005-05-12","lastDate":"2005-05-12","metrics":{"recentRows":0,"currentOperatorTenures":5,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":13,"firstDate":"2005-05-17","lastDate":"2007-04-13","metrics":{"inspectors":34,"recentRows":0,"onSiteHours":480.5,"inspectionHours":752.25,"inspectionSamples":68},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"999969","EVENT_NO":"4199852","INSPECTION_BEGIN_DT":"04/13/2007","INSPECTION_END_DT":"04/25/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"9","sourceDate":"2007-04-13"},{"SOURCE_ROW_NUMBER":"142979","EVENT_NO":"4177196","INSPECTION_BEGIN_DT":"01/24/2007","INSPECTION_END_DT":"03/23/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2007-01-24"},{"SOURCE_ROW_NUMBER":"92296","EVENT_NO":"4177189","INSPECTION_BEGIN_DT":"10/02/2006","INSPECTION_END_DT":"12/07/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"98","SUM_TOTAL_ON_SITE_HOURS":"57","sourceDate":"2006-10-02"},{"SOURCE_ROW_NUMBER":"120667","EVENT_NO":"4189673","INSPECTION_BEGIN_DT":"09/21/2006","INSPECTION_END_DT":"09/21/2006","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2006-09-21"},{"SOURCE_ROW_NUMBER":"495312","EVENT_NO":"4177316","INSPECTION_BEGIN_DT":"07/03/2006","INSPECTION_END_DT":"09/14/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"117.75","SUM_TOTAL_ON_SITE_HOURS":"77.5","sourceDate":"2006-07-03"},{"SOURCE_ROW_NUMBER":"309750","EVENT_NO":"4177308","INSPECTION_BEGIN_DT":"04/04/2006","INSPECTION_END_DT":"06/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"158.75","SUM_TOTAL_ON_SITE_HOURS":"103.25","sourceDate":"2006-04-04"},{"SOURCE_ROW_NUMBER":"651254","EVENT_NO":"4176990","INSPECTION_BEGIN_DT":"01/04/2006","INSPECTION_END_DT":"03/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"6","SUM_TOTAL_INSP_HOURS":"123.5","SUM_TOTAL_ON_SITE_HOURS":"87.25","sourceDate":"2006-01-04"},{"SOURCE_ROW_NUMBER":"296021","EVENT_NO":"4179317","INSPECTION_BEGIN_DT":"10/27/2005","INSPECTION_END_DT":"11/02/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2005-10-27"},{"SOURCE_ROW_NUMBER":"528495","EVENT_NO":"4176986","INSPECTION_BEGIN_DT":"10/12/2005","INSPECTION_END_DT":"12/29/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"41.75","SUM_TOTAL_ON_SITE_HOURS":"26","sourceDate":"2005-10-12"},{"SOURCE_ROW_NUMBER":"40461","EVENT_NO":"4178597","INSPECTION_BEGIN_DT":"10/05/2005","INSPECTION_END_DT":"10/05/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2005-10-05"},{"SOURCE_ROW_NUMBER":"41732","EVENT_NO":"4177161","INSPECTION_BEGIN_DT":"07/07/2005","INSPECTION_END_DT":"09/26/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"75","SUM_TOTAL_ON_SITE_HOURS":"51","sourceDate":"2005-07-07"},{"SOURCE_ROW_NUMBER":"399153","EVENT_NO":"4177153","INSPECTION_BEGIN_DT":"06/02/2005","INSPECTION_END_DT":"06/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"85","SUM_TOTAL_ON_SITE_HOURS":"52","sourceDate":"2005-06-02"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":18,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q2":{"hours":0,"employees":0,"production":0},"2007-Q1":{"hours":0,"employees":0,"production":0},"2006-Q4":{"hours":2604,"employees":11,"production":6517},"2006-Q3":{"hours":6397,"employees":13,"production":13920},"2006-Q2":{"hours":6090,"employees":11,"production":15102},"2006-Q1":{"hours":5530,"employees":11,"production":6756},"2005-Q4":{"hours":1420,"employees":11,"production":1429},"2005-Q3":{"hours":6324,"employees":11,"production":13503},"2005-Q2":{"hours":2975,"employees":12,"production":3022}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2005":{"hours":10719,"employees":11,"production":17954},"2006":{"hours":20621,"employees":12,"production":42295}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2005-08-10","lastDate":"2006-10-12","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":587,"pelDoseTotal":393},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"88953","EVENT_NO":"4177189","SURVEY_DATE":"10/12/2006","OCCUPATION_CD_DESC":"LABORER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"30","PEL_DOSE_90":"19","SURVEY_TYPE":"I","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"88952","EVENT_NO":"4177189","SURVEY_DATE":"10/12/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"36","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"88951","EVENT_NO":"4177189","SURVEY_DATE":"10/12/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"24","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"88950","EVENT_NO":"4177189","SURVEY_DATE":"10/12/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"24","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"88949","EVENT_NO":"4177189","SURVEY_DATE":"10/12/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"58","PEL_DOSE_90":"42","SURVEY_TYPE":"I","sourceDate":"2006-10-12"},{"SOURCE_ROW_NUMBER":"88943","EVENT_NO":"4176990","SURVEY_DATE":"03/13/2006","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"33","PEL_DOSE_90":"23","SURVEY_TYPE":"I","sourceDate":"2006-03-13"},{"SOURCE_ROW_NUMBER":"88942","EVENT_NO":"4176990","SURVEY_DATE":"03/13/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"033","ACT_DOSE_85":"58","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2006-03-13"},{"SOURCE_ROW_NUMBER":"88941","EVENT_NO":"4176990","SURVEY_DATE":"03/13/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"45","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2006-03-13"},{"SOURCE_ROW_NUMBER":"88940","EVENT_NO":"4176990","SURVEY_DATE":"03/13/2006","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"43","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2006-03-13"},{"SOURCE_ROW_NUMBER":"88939","EVENT_NO":"4176990","SURVEY_DATE":"03/13/2006","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"033","ACT_DOSE_85":"41","PEL_DOSE_90":"34","SURVEY_TYPE":"I","sourceDate":"2006-03-13"},{"SOURCE_ROW_NUMBER":"88948","EVENT_NO":"4177161","SURVEY_DATE":"08/10/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"23","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2005-08-10"},{"SOURCE_ROW_NUMBER":"88947","EVENT_NO":"4177161","SURVEY_DATE":"08/10/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"50","PEL_DOSE_90":"38","SURVEY_TYPE":"I","sourceDate":"2005-08-10"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":5,"firstDate":"2005-08-10","lastDate":"2006-05-31","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":10.4,"validSamples":5,"quartzPctTotal":34.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"141726","CASSETTE_NO":"50858247","SAMPLE_DT":"05/31/2006","QUARTZ_PCT":"09.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-05-31"},{"SOURCE_ROW_NUMBER":"57943","CASSETTE_NO":"57556371","SAMPLE_DT":"05/02/2006","QUARTZ_PCT":"10.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-05-02"},{"SOURCE_ROW_NUMBER":"54686","CASSETTE_NO":"57556374","SAMPLE_DT":"05/02/2006","QUARTZ_PCT":"07.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-05-02"},{"SOURCE_ROW_NUMBER":"92821","CASSETTE_NO":"57619896","SAMPLE_DT":"02/15/2006","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-15"},{"SOURCE_ROW_NUMBER":"32950","CASSETTE_NO":"57545907","SAMPLE_DT":"08/10/2005","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-10"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":57,"firstDate":"2005-06-07","lastDate":"2006-10-19","metrics":{"ss":19,"amountDue":4087,"contested":0,"amountPaid":3955,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":4087},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1081286","VIOLATION_NO":"7438085","VIOLATION_ISSUE_DT":"10/19/2006","SIG_SUB":"N","PART_SECTION":"75.1103-8(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/23/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"1081285","VIOLATION_NO":"7438084","VIOLATION_ISSUE_DT":"10/19/2006","SIG_SUB":"Y","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/23/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"1081284","VIOLATION_NO":"7438083","VIOLATION_ISSUE_DT":"10/19/2006","SIG_SUB":"N","PART_SECTION":"75.512-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/23/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-19"},{"SOURCE_ROW_NUMBER":"1081287","VIOLATION_NO":"9881141","VIOLATION_ISSUE_DT":"10/11/2006","SIG_SUB":"N","PART_SECTION":"70.208(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/11/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-11"},{"SOURCE_ROW_NUMBER":"1081273","VIOLATION_NO":"7437853","VIOLATION_ISSUE_DT":"09/11/2006","SIG_SUB":"Y","PART_SECTION":"75.521","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/12/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"1081272","VIOLATION_NO":"7437852","VIOLATION_ISSUE_DT":"09/11/2006","SIG_SUB":"N","PART_SECTION":"75.1712-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"NoNegligence","TERMINATION_DT":"09/25/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"1081277","VIOLATION_NO":"7437976","VIOLATION_ISSUE_DT":"08/10/2006","SIG_SUB":"N","PART_SECTION":"75.1100-2(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/14/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-08-10"},{"SOURCE_ROW_NUMBER":"1081276","VIOLATION_NO":"7437971","VIOLATION_ISSUE_DT":"08/01/2006","SIG_SUB":"N","PART_SECTION":"75.1100-2(e)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/01/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-08-01"},{"SOURCE_ROW_NUMBER":"1081275","VIOLATION_NO":"7437970","VIOLATION_ISSUE_DT":"07/28/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/01/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-07-28"},{"SOURCE_ROW_NUMBER":"1081274","VIOLATION_NO":"7437968","VIOLATION_ISSUE_DT":"07/24/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"07/28/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-07-24"},{"SOURCE_ROW_NUMBER":"1081266","VIOLATION_NO":"7437966","VIOLATION_ISSUE_DT":"06/28/2006","SIG_SUB":"Y","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/29/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-06-28"},{"SOURCE_ROW_NUMBER":"1081265","VIOLATION_NO":"7437965","VIOLATION_ISSUE_DT":"05/31/2006","SIG_SUB":"Y","PART_SECTION":"77.701","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/31/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-05-31"}]}],"safety":{"href":"/api/v1/mines/1518871/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518871/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-8","heading":"Automatic fire sensor and warning device systems; examination and test requirements.","id":"75.1103-8","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-8","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Automatic fire sensor and warning device systems shall be examined at least once each shift when belts are operated as part of a production shift. A functional test of the warning signals shall be made at least once every seven days. Examination and maintenance of such systems shall be by a qualified person.\n\n(b) A record of the functional test conducted in accordance with paragraph (a) of this section shall be maintained by the operator and kept for a period of one year.\n\n(c) Sensors shall be calibrated in accordance with the manufacturer's calibration instructions at intervals not to exceed 31 days. A record of the sensor calibrations shall be maintained by the operator and kept for a period of one year.\n\n[73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512-2","heading":"Frequency of examinations.","id":"75.512-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"The examinations and tests required by § 75.512 shall be made at least weekly. Permissible equipment shall be examined to see that it is in permissible condition.","occurrenceCount":1},{"chapter":"I","heading":"Quarterly sampling; mechanized mining units.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-70/subpart-C/section-70.208","part":"70","subchapter":"O","subpart":"C","id":"70.208","citation":"30 CFR 70.208","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 70—MANDATORY HEALTH STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Lightning arresters; ungrounded and exposed power conductors and telephone wires.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.521","part":"75","subchapter":"O","subpart":"F","id":"75.521","citation":"30 CFR 75.521","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Location of surface facilities.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1712-2","part":"75","subchapter":"O","subpart":"R","id":"75.1712-2","citation":"30 CFR 75.1712-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-2","heading":"Quantity and location of firefighting equipment.","id":"75.1100-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the following:\n\n(i) Two portable water cars; or\n\n(ii) Two portable chemical cars; or\n\n(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.\n\n(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Two portable fire extinguishers; and\n\n(ii) 240 pounds of rock dust in bags or other suitable containers; and\n\n(iii) At least 500 gallons of water and at least three pails of 10-quart capacity; or a waterline with sufficient hose to reach the working places; or a portable water car of at least 500-gallons capacity; or a portable, all-purpose, dry-powder chemical car of at least 125-pounds capacity.\n\n(3) As an alternative to paragraph (a)(2) of this section, each working section with no electrical equipment at the face of an anthracite coal mine producing less than 300 tons of coal per shift shall be provided with the following:\n\n(i) Portable fire extinguishers containing a total capacity of at least 30 pounds of dry chemical or 15 gallons of foam and located at the entrance to the gangway at the bottom of the slope; and\n\n(ii) Portable fire extinguishers containing a total capacity of at least 20 pounds of dry chemical or 10 gallons of foam and located within 500 feet from the working face.\n\n(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Waterlines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.\n\n(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connection with such waterlines shall be provided at strategic locations. Two portable water cars, readily available, may be used in lieu of waterlines prescribed under this paragraph.\n\n(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:\n\n(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or\n\n(ii) Not less than 240 pounds of bagged rock dust.\n\n(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.\n\n(e) Electrical installations. At each electrical installation, the operator shall provide two portable fire extinguishers that have a nominal capacity of 5 pounds of dry chemical, or one extinguisher that has a nominal capacity of at least 10 pounds of dry chemical, and which have a 2-A:10-B:C or higher rating.\n\n(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust, shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.\n\n(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.\n\n(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.\n\n(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:\n\n1,000 board feet of brattice boards 2 rolls of brattice cloth 2 hand saws 25 pounds of 8 d nails 25 pounds of 10 d nails 25 pounds of 16 d nails 3 claw hammers 25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings) 5 tons of rock dust\n\n(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 73 FR 53127, Sept. 15, 2008]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":1},{"chapter":"I","heading":"Grounding metallic frames, casings, and other enclosures of electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-H/section-77.701","part":"77","subchapter":"O","subpart":"H","id":"77.701","citation":"30 CFR 77.701","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518871","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}