{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518776","name":"#7","status":"Abandoned and Sealed","status_date":"2005-10-12","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Letcher","nearest_town":"Dean","operator_id":"P19994","operator_name":"J&R Coal Inc.","controller_id":"C13662","controller_name":"Roger N  Bentley","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.232777,"longitude":-82.816666},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":275},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518776","name":"#7"},"operator":{"type":"operator","id":"P19994","name":"J&R Coal Inc."},"controller":{"type":"controller","id":"C13662","name":"Roger N  Bentley"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13662","name":"Roger N  Bentley"},"object":{"type":"mine","id":"1518776","name":"#7"},"validFrom":"1988-11-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518776|C13662|1988-11-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19994","name":"J&R Coal Inc."},"object":{"type":"mine","id":"1518776","name":"#7"},"validFrom":"2004-06-30","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518776|P19994|2004-06-30|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13662","name":"Roger N  Bentley"},"object":{"type":"operator","id":"P19994","name":"J&R Coal Inc."},"validFrom":"2004-06-30","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518776","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518776|P19994|2004-06-30|C13662|1988-11-01|90740"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":3,"firstDate":"2005-02-25","lastDate":"2005-09-12","metrics":{"daysLost":454,"injuries":3,"fatalities":0,"recentRows":0,"restrictedDays":10,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"121774","DOCUMENT_NO":"220052560017","ACCIDENT_DT":"09/12/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"IGNITION OR EXPLOSION OF GAS OR DUST","ACCIDENT_TYPE":"Contact with hot objects or substances","OCCUPATION":"Driller operator","NO_INJURIES":"1","DAYS_LOST":"193","NARRATIVE":"EE WAS DRILLING COAL WHEN METHANE IGNITED CAUSING AN EXPLOSION & BURNING EE ON FACE AND BOTH HANDS. EE WAS TAKEN TO WHITESBURG ARH THEN AIR LIFTED TO LEXINGTON KY.","sourceDate":"2005-09-12"},{"SOURCE_ROW_NUMBER":"147791","DOCUMENT_NO":"220051730014","ACCIDENT_DT":"06/16/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"6","NARRATIVE":"Employee was operating a roof bolter when a piece of draw rock fell on his left shoulder and neck approximately 3' x 18\" x 6\" dislocating his left shoulder.","sourceDate":"2005-06-16"},{"SOURCE_ROW_NUMBER":"104464","DOCUMENT_NO":"220050660015","ACCIDENT_DT":"02/25/2005","DEGREE_INJURY":"DYS AWY FRM WRK & RESTRCTD ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"255","NARRATIVE":"Employee was tramming bolter across section and the back of the bolter caught on roof","sourceDate":"2005-02-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2005-10-12","lastDate":"2005-10-12","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":62,"firstDate":"2004-09-20","lastDate":"2005-09-20","metrics":{"ss":39,"delinquent":59,"recentRows":0,"paidPenalty":110608,"proposedPenalty":153908,"currentAssessment":110608},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"993721","VIOLATION_NO":"7418836","ISSUE_DT":"09/20/2005","CFR_STANDARD_CD":"75.360","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"42500.00","CURRENT_ASSESSMENT_AMT":"28000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"993720","VIOLATION_NO":"7418832","ISSUE_DT":"09/20/2005","CFR_STANDARD_CD":"75.362(a)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"18100.00","CURRENT_ASSESSMENT_AMT":"12000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"993719","VIOLATION_NO":"7418831","ISSUE_DT":"09/20/2005","CFR_STANDARD_CD":"75.362(d)(1)(i)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"18100.00","CURRENT_ASSESSMENT_AMT":"14000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"993718","VIOLATION_NO":"7418830","ISSUE_DT":"09/20/2005","CFR_STANDARD_CD":"75.320(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"18100.00","CURRENT_ASSESSMENT_AMT":"14500.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"993717","VIOLATION_NO":"7418829","ISSUE_DT":"09/20/2005","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"42500.00","CURRENT_ASSESSMENT_AMT":"30500.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"956884","VIOLATION_NO":"7418834","ISSUE_DT":"09/20/2005","CFR_STANDARD_CD":"75.362(d)(1)(iii)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"4500.00","CURRENT_ASSESSMENT_AMT":"3000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"956883","VIOLATION_NO":"7418833","ISSUE_DT":"09/20/2005","CFR_STANDARD_CD":"75.362(d)(1)(ii)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"4500.00","CURRENT_ASSESSMENT_AMT":"3000.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"956892","VIOLATION_NO":"7419041","ISSUE_DT":"09/19/2005","CFR_STANDARD_CD":"75.512","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"956891","VIOLATION_NO":"7419040","ISSUE_DT":"09/19/2005","CFR_STANDARD_CD":"75.500(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"956890","VIOLATION_NO":"7419039","ISSUE_DT":"09/19/2005","CFR_STANDARD_CD":"75.606","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"956889","VIOLATION_NO":"7419038","ISSUE_DT":"09/19/2005","CFR_STANDARD_CD":"75.514","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"956888","VIOLATION_NO":"7419037","ISSUE_DT":"09/19/2005","CFR_STANDARD_CD":"75.604","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-09-19"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":7,"firstDate":"2007-08-22","lastDate":"2007-08-22","metrics":{"appeals":0,"decisions":7,"recentRows":0,"decisionPenalty":105000,"originalPenalty":148300},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"192562","VIOLATION_NO":"7418830","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18100.00","DECISION_PENALTY_AMT":"14500.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"192561","VIOLATION_NO":"7418829","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"42500.00","DECISION_PENALTY_AMT":"30500.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"192193","VIOLATION_NO":"7418832","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18100.00","DECISION_PENALTY_AMT":"12000.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"192192","VIOLATION_NO":"7418831","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"18100.00","DECISION_PENALTY_AMT":"14000.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"192019","VIOLATION_NO":"7418836","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"42500.00","DECISION_PENALTY_AMT":"28000.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"191868","VIOLATION_NO":"7418834","DOCKET_NO":"KENT 2006-235","DECISION_DT":"08/22/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4500.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2007-08-22"},{"SOURCE_ROW_NUMBER":"6533","VIOLATION_NO":"7418833","DOCKET_NO":"KENT 2006-235","DECISION_DT":"08/22/2007","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4500.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"Avram","JUDGE_LAST_NAME":"Weisberger","sourceDate":"2007-08-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":70,"firstDate":"2004-10-11","lastDate":"2005-09-08","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":8,"validSamples":62,"maxConcentration":5.623,"concentrationTotal":59.726},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1536504","CASS_NUM":"57584514","SMP_TAKEN_DT":"9/8/2005","CONC":".741","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"1394794","CASS_NUM":"57584488","SMP_TAKEN_DT":"9/8/2005","CONC":".69","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"910952","CASS_NUM":"57584449","SMP_TAKEN_DT":"9/8/2005","CONC":"3.03","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"OCCP CODE-METH MINING MISMATCH","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"747523","CASS_NUM":"57584442","SMP_TAKEN_DT":"9/8/2005","CONC":".658","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"465263","CASS_NUM":"57584486","SMP_TAKEN_DT":"9/8/2005","CONC":"2.347","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"1472835","CASS_NUM":"57584813","SMP_TAKEN_DT":"7/26/2005","CONC":".42","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"848889","CASS_NUM":"57584793","SMP_TAKEN_DT":"7/26/2005","CONC":".335","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"658373","CASS_NUM":"57584768","SMP_TAKEN_DT":"7/26/2005","CONC":".505","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"408352","CASS_NUM":"57584749","SMP_TAKEN_DT":"7/26/2005","CONC":".349","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"342364","CASS_NUM":"57584778","SMP_TAKEN_DT":"7/26/2005","CONC":".569","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-07-26"},{"SOURCE_ROW_NUMBER":"522313","CASS_NUM":"50811493","SMP_TAKEN_DT":"7/19/2005","CONC":".383","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-07-19"},{"SOURCE_ROW_NUMBER":"934492","CASS_NUM":"50811444","SMP_TAKEN_DT":"7/18/2005","CONC":".242","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-07-18"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":9,"firstDate":"2005-10-17","lastDate":"2005-10-17","metrics":{"linkedIssuances":9},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":10,"firstDate":"2005-09-20","lastDate":"2005-09-20","metrics":{"decisions":10,"ssChanged":0,"recentRows":0,"decisionPenalty":110900,"proposedPenalty":160050},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"397069","CITATION_NO":"7418829-00007354A","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-48","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":"2900.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"397068","CITATION_NO":"7418829","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.370(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"42500.00","DECISION_PENALTY_AMT":"30500.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"228085","CITATION_NO":"7418832","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.362(a)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"18100.00","DECISION_PENALTY_AMT":"12000.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"228084","CITATION_NO":"7418836","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.360","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"42500.00","DECISION_PENALTY_AMT":"28000.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"171380","CITATION_NO":"7418832-00007354A","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-48","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.362(a)(2)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1750.00","DECISION_PENALTY_AMT":"500.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"170712","CITATION_NO":"7418830","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.320(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"18100.00","DECISION_PENALTY_AMT":"14500.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"114407","CITATION_NO":"7418836-00007354A","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-48","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.360","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5000.00","DECISION_PENALTY_AMT":"2500.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"58823","CITATION_NO":"7418831","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2007-84","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.362(d)(1)(i)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"18100.00","DECISION_PENALTY_AMT":"14000.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"58647","CITATION_NO":"7418834","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2006-235","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.362(d)(1)(iii)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4500.00","DECISION_PENALTY_AMT":"3000.00","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"58646","CITATION_NO":"7418833","CITATION_ISSUE_DT":"09/20/2005","DOCKET_NO":"KENT 2006-235","DECISION_DT":"08/22/2007","CFR_STANDARD_CODE":"75.362(d)(1)(ii)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"4500.00","DECISION_PENALTY_AMT":"3000.00","sourceDate":"2005-09-20"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2004-06-30","lastDate":"2004-06-30","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":13,"firstDate":"2004-07-20","lastDate":"2005-10-03","metrics":{"inspectors":28,"recentRows":0,"onSiteHours":221.75,"inspectionHours":491.25,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"426080","EVENT_NO":"4181853","INSPECTION_BEGIN_DT":"10/03/2005","INSPECTION_END_DT":"10/12/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2005-10-03"},{"SOURCE_ROW_NUMBER":"913117","EVENT_NO":"4181812","INSPECTION_BEGIN_DT":"09/12/2005","INSPECTION_END_DT":"10/14/2005","ACTIVITY_CODE":"E07","ACTIVITY":"Non-Fatal Accident Investigation","NBR_INSPECTOR":"5","SUM_TOTAL_INSP_HOURS":"184.75","SUM_TOTAL_ON_SITE_HOURS":"57.25","sourceDate":"2005-09-12"},{"SOURCE_ROW_NUMBER":"864975","EVENT_NO":"4167931","INSPECTION_BEGIN_DT":"07/25/2005","INSPECTION_END_DT":"09/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"63.5","SUM_TOTAL_ON_SITE_HOURS":"26.5","sourceDate":"2005-07-25"},{"SOURCE_ROW_NUMBER":"597397","EVENT_NO":"4167927","INSPECTION_BEGIN_DT":"05/19/2005","INSPECTION_END_DT":"06/29/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"57.5","SUM_TOTAL_ON_SITE_HOURS":"37","sourceDate":"2005-05-19"},{"SOURCE_ROW_NUMBER":"1037420","EVENT_NO":"4181374","INSPECTION_BEGIN_DT":"01/10/2005","INSPECTION_END_DT":"03/18/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"24.5","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"924476","EVENT_NO":"4181375","INSPECTION_BEGIN_DT":"01/10/2005","INSPECTION_END_DT":"01/28/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"667559","EVENT_NO":"4181361","INSPECTION_BEGIN_DT":"10/12/2004","INSPECTION_END_DT":"12/08/2004","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2004-10-12"},{"SOURCE_ROW_NUMBER":"931338","EVENT_NO":"6139540","INSPECTION_BEGIN_DT":"10/04/2004","INSPECTION_END_DT":"12/13/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"48","SUM_TOTAL_ON_SITE_HOURS":"30","sourceDate":"2004-10-04"},{"SOURCE_ROW_NUMBER":"703363","EVENT_NO":"6139539","INSPECTION_BEGIN_DT":"09/27/2004","INSPECTION_END_DT":"10/07/2004","ACTIVITY_CODE":"CBC","ACTIVITY":"ELECTRICAL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"24","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2004-09-27"},{"SOURCE_ROW_NUMBER":"766069","EVENT_NO":"6141673","INSPECTION_BEGIN_DT":"09/02/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"31","SUM_TOTAL_ON_SITE_HOURS":"19.5","sourceDate":"2004-09-02"},{"SOURCE_ROW_NUMBER":"809388","EVENT_NO":"4178363","INSPECTION_BEGIN_DT":"09/01/2004","INSPECTION_END_DT":"09/01/2004","ACTIVITY_CODE":"BAE","ACTIVITY":"SFTY & HLTH (SHFTS,SLPES, & SITES)","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2004-09-01"},{"SOURCE_ROW_NUMBER":"1150591","EVENT_NO":"4178358","INSPECTION_BEGIN_DT":"08/13/2004","INSPECTION_END_DT":"08/13/2004","ACTIVITY_CODE":"BAE","ACTIVITY":"SFTY & HLTH (SHFTS,SLPES, & SITES)","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2004-08-13"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":24,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2008-Q2":{"hours":0,"employees":0,"production":0},"2007-Q1":{"hours":0,"employees":0,"production":0},"2006-Q4":{"hours":0,"employees":0,"production":0},"2006-Q3":{"hours":0,"employees":0,"production":0},"2006-Q2":{"hours":0,"employees":0,"production":0},"2006-Q1":{"hours":0,"employees":0,"production":0},"2005-Q4":{"hours":720,"employees":9,"production":0},"2005-Q3":{"hours":12924,"employees":23,"production":27394},"2005-Q2":{"hours":9129,"employees":17,"production":48083},"2005-Q1":{"hours":4634,"employees":11,"production":8846},"2004-Q4":{"hours":4263,"employees":7,"production":4328},"2004-Q3":{"hours":2103,"employees":6,"production":1097}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":6366,"employees":7,"production":5425},"2005":{"hours":27407,"employees":15,"production":84323}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":5,"firstDate":"2005-09-08","lastDate":"2005-09-08","metrics":{"recentRows":0,"doseOver100":1,"actDoseTotal":353,"pelDoseTotal":264},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"86108","EVENT_NO":"4167931","SURVEY_DATE":"09/08/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"67","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"86107","EVENT_NO":"4167931","SURVEY_DATE":"09/08/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"139","PEL_DOSE_90":"129","SURVEY_TYPE":"I","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"86106","EVENT_NO":"4167931","SURVEY_DATE":"09/08/2005","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"35","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"86105","EVENT_NO":"4167931","SURVEY_DATE":"09/08/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"30","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"86104","EVENT_NO":"4167931","SURVEY_DATE":"09/08/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"82","PEL_DOSE_90":"55","SURVEY_TYPE":"I","sourceDate":"2005-09-08"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":2,"firstDate":"2004-11-29","lastDate":"2005-09-08","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":11.3,"validSamples":2,"quartzPctTotal":18.8},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"98051","CASSETTE_NO":"57584486","SAMPLE_DT":"09/08/2005","QUARTZ_PCT":"11.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"107623","CASSETTE_NO":"57490499","SAMPLE_DT":"11/29/2004","QUARTZ_PCT":"07.5","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-11-29"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":63,"firstDate":"2004-09-20","lastDate":"2005-09-20","metrics":{"ss":39,"amountDue":110608,"contested":7,"amountPaid":110608,"recentRows":0,"section104d":7,"unterminated":0,"proposedPenalty":153908},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1062914","VIOLATION_NO":"7418836","VIOLATION_ISSUE_DT":"09/20/2005","SIG_SUB":"Y","PART_SECTION":"75.360","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"12","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/12/2005","PROPOSED_PENALTY":"42500","AMOUNT_DUE":"28000","AMOUNT_PAID":"28000","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2007-84","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"1062913","VIOLATION_NO":"7418832","VIOLATION_ISSUE_DT":"09/20/2005","SIG_SUB":"Y","PART_SECTION":"75.362(a)(2)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"04/19/2006","PROPOSED_PENALTY":"18100","AMOUNT_DUE":"12000","AMOUNT_PAID":"12000","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2007-84","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"1062912","VIOLATION_NO":"7418831","VIOLATION_ISSUE_DT":"09/20/2005","SIG_SUB":"Y","PART_SECTION":"75.362(d)(1)(i)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/12/2005","PROPOSED_PENALTY":"18100","AMOUNT_DUE":"14000","AMOUNT_PAID":"14000","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2007-84","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"1062911","VIOLATION_NO":"7418830","VIOLATION_ISSUE_DT":"09/20/2005","SIG_SUB":"Y","PART_SECTION":"75.320(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Occurred","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/12/2005","PROPOSED_PENALTY":"18100","AMOUNT_DUE":"14500","AMOUNT_PAID":"14500","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2007-84","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"1062910","VIOLATION_NO":"7418829","VIOLATION_ISSUE_DT":"09/20/2005","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"12","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/12/2005","PROPOSED_PENALTY":"42500","AMOUNT_DUE":"30500","AMOUNT_PAID":"30500","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2007-84","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"1062894","VIOLATION_NO":"7418834","VIOLATION_ISSUE_DT":"09/20/2005","SIG_SUB":"Y","PART_SECTION":"75.362(d)(1)(iii)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"12","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/12/2005","PROPOSED_PENALTY":"4500","AMOUNT_DUE":"3000","AMOUNT_PAID":"3000","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2006-235","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"1062893","VIOLATION_NO":"7418833","VIOLATION_ISSUE_DT":"09/20/2005","SIG_SUB":"Y","PART_SECTION":"75.362(d)(1)(ii)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Highly","INJ_ILLNESS":"Permanent","NO_AFFECTED":"12","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"10/12/2005","PROPOSED_PENALTY":"4500","AMOUNT_DUE":"3000","AMOUNT_PAID":"3000","CONTESTED_IND":"Y","DOCKET_NO":"KENT 2006-235","sourceDate":"2005-09-20"},{"SOURCE_ROW_NUMBER":"1062902","VIOLATION_NO":"7419041","VIOLATION_ISSUE_DT":"09/19/2005","SIG_SUB":"Y","PART_SECTION":"75.512","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2005","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"1062901","VIOLATION_NO":"7419040","VIOLATION_ISSUE_DT":"09/19/2005","SIG_SUB":"Y","PART_SECTION":"75.500(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2005","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"1062900","VIOLATION_NO":"7419039","VIOLATION_ISSUE_DT":"09/19/2005","SIG_SUB":"Y","PART_SECTION":"75.606","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/23/2005","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"1062899","VIOLATION_NO":"7419038","VIOLATION_ISSUE_DT":"09/19/2005","SIG_SUB":"Y","PART_SECTION":"75.514","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/19/2005","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2005-09-19"},{"SOURCE_ROW_NUMBER":"1062898","VIOLATION_NO":"7419037","VIOLATION_ISSUE_DT":"09/19/2005","SIG_SUB":"Y","PART_SECTION":"75.604","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/19/2005","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2005-09-19"}]}],"safety":{"href":"/api/v1/mines/1518776/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518776/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":4},{"chapter":"I","heading":"Air quality detectors and measurement devices.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.320","part":"75","subchapter":"O","subpart":"D","id":"75.320","citation":"30 CFR 75.320","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512","heading":"Electric equipment; examination, testing and maintenance.","id":"75.512","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provision]\n\nAll electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Permissible electric equipment.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.500","part":"75","subchapter":"O","subpart":"F","id":"75.500","citation":"30 CFR 75.500","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.606","heading":"Protection of trailing cables.","id":"75.606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.606","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nTrailing cables shall be adequately protected to prevent damage by mobile equipment.","occurrenceCount":1},{"chapter":"I","heading":"Electrical connections or splices; suitability.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.514","part":"75","subchapter":"O","subpart":"F","id":"75.514","citation":"30 CFR 75.514","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518776","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}