{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518753","name":"#1","status":"Abandoned and Sealed","status_date":"2007-10-17","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Knott","nearest_town":"Kite","operator_id":"0052459","operator_name":"Vision Coal Inc.","controller_id":"0101685","controller_name":"Kevin R Yonts","district":"C05","office":"Norton VA Field Office","employees":0,"latitude":37.275555,"longitude":-82.776944},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":1192},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518753","name":"#1"},"operator":{"type":"operator","id":"0052459","name":"Vision Coal Inc."},"controller":{"type":"controller","id":"0101685","name":"Kevin R Yonts"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"operator_operates_mine","subject":{"type":"operator","id":"0052459","name":"Vision Coal Inc."},"object":{"type":"mine","id":"1518753","name":"#1"},"validFrom":"2004-05-06","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518753|0052459|2004-05-06|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0043299","name":"Dennis Creg  Yonts"},"object":{"type":"mine","id":"1518753","name":"#1"},"validFrom":"2004-05-06","validTo":"2007-09-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518753|0043299|2004-05-06|2007-09-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0043299","name":"Dennis Creg  Yonts"},"object":{"type":"operator","id":"0052459","name":"Vision Coal Inc."},"validFrom":"2004-05-06","validTo":"2007-09-11","current":false,"derived":true,"evidenceMineId":"1518753","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518753|0052459|2004-05-06|0043299|2004-05-06|4549"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0101685","name":"Kevin R Yonts"},"object":{"type":"mine","id":"1518753","name":"#1"},"validFrom":"2007-09-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518753|0101685|2007-09-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0101685","name":"Kevin R Yonts"},"object":{"type":"operator","id":"0052459","name":"Vision Coal Inc."},"validFrom":"2007-09-12","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518753","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518753|0052459|2004-05-06|0101685|2007-09-12|17313"}}],"coverage":{"historyRecords":2,"edgeCount":5,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":6,"firstDate":"2004-10-12","lastDate":"2006-09-11","metrics":{"daysLost":174,"injuries":6,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":6},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"18682","DOCUMENT_NO":"220062690058","ACCIDENT_DT":"09/11/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Outside foreman, Leadman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Injured ee was using a chisel and hammer to break a piece of metal off of a chain hoist. When the piece of metal broke off, it fell on the injured ehis left hand, bruising the index, middle, and ring fingers.","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"27393","DOCUMENT_NO":"220061080034","ACCIDENT_DT":"04/07/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"STEPPING OR KNEELING ON OBJECT","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"36","NARRATIVE":"Injured employee was working on a belt splice when he stepped on a rock or lump of coal and twisted his right ankle resulting in a broken bone just above the ankle.","sourceDate":"2006-04-07"},{"SOURCE_ROW_NUMBER":"199272","DOCUMENT_NO":"220060820055","ACCIDENT_DT":"03/16/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Blacksmith, Bull gang, Parts runner, Roustabout, Pick-up man, Pitman","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"INJURED EMPLOYEE WAS PICKING ROCKS OFF OF SCALPER BELT WHEN ROCK CAME OFF THE SCALPER SCREEN & HIT HIS LEFT HAND. THIS RESULTED IN A CUT ON HIS HAND (2 STITCHES) & TWO BROKEN BONES IN THE LEFT HAND ON THE LITTLE FINGER.","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"65932","DOCUMENT_NO":"220060520097","ACCIDENT_DT":"02/10/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"20","NARRATIVE":"Employee was removing a metal cover on the face drill when he felt a sharp pain in his lower abdomen, resulting in a hernia/rupture.","sourceDate":"2006-02-10"},{"SOURCE_ROW_NUMBER":"190683","DOCUMENT_NO":"220050280036","ACCIDENT_DT":"01/18/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"ELECTRICAL","ACCIDENT_TYPE":"Flash burns (electric)","OCCUPATION":"Laborer, Bull gang, Faceman, Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"EE PLUGGED IN THE CATHEAD FOR THE #4 BOLTING MACHINE AND SET UP THE BREAKER. THE BOLTING MACHINE WAS TURNED ON AND AN ARC FLASH CAME FROM THE CATHEAD. THE FLASH CAUSED A BURN INJURY TO THE EE's FACE.","sourceDate":"2005-01-18"},{"SOURCE_ROW_NUMBER":"100259","DOCUMENT_NO":"220043000029","ACCIDENT_DT":"10/12/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"65","NARRATIVE":"THE INJURED EMPLOYEE WAS BENDING A ROOF BOLT MANUALLY WHEN HE FELT A PAIN IN HIS RIGHT SHOULDER, LATER DIAGNOSED AS A STRAIN IN THE RIGHT SHOULDER.","sourceDate":"2004-10-12"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-10-17","lastDate":"2007-10-17","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":261,"firstDate":"2004-08-23","lastDate":"2007-06-07","metrics":{"ss":126,"delinquent":261,"recentRows":0,"paidPenalty":990.07,"proposedPenalty":40142,"currentAssessment":40142},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1413632","VIOLATION_NO":"7548267","ISSUE_DT":"06/07/2007","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"317.00","CURRENT_ASSESSMENT_AMT":"317.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-06-07"},{"SOURCE_ROW_NUMBER":"1413621","VIOLATION_NO":"7423673","ISSUE_DT":"05/07/2007","CFR_STANDARD_CD":"75.312(e)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-07"},{"SOURCE_ROW_NUMBER":"1413620","VIOLATION_NO":"7423672","ISSUE_DT":"05/07/2007","CFR_STANDARD_CD":"75.1202-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-07"},{"SOURCE_ROW_NUMBER":"1413619","VIOLATION_NO":"7423671","ISSUE_DT":"05/07/2007","CFR_STANDARD_CD":"75.360(f)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"190.00","CURRENT_ASSESSMENT_AMT":"190.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-05-07"},{"SOURCE_ROW_NUMBER":"1413631","VIOLATION_NO":"7548244","ISSUE_DT":"04/30/2007","CFR_STANDARD_CD":"77.1606(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"243.00","CURRENT_ASSESSMENT_AMT":"243.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1413630","VIOLATION_NO":"7548243","ISSUE_DT":"04/30/2007","CFR_STANDARD_CD":"75.342(a)(4)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1413629","VIOLATION_NO":"7548242","ISSUE_DT":"04/30/2007","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"585.00","CURRENT_ASSESSMENT_AMT":"585.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1413628","VIOLATION_NO":"7548241","ISSUE_DT":"04/30/2007","CFR_STANDARD_CD":"75.523-3(b)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"224.00","CURRENT_ASSESSMENT_AMT":"224.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1413627","VIOLATION_NO":"7548240","ISSUE_DT":"04/24/2007","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"1413626","VIOLATION_NO":"7548239","ISSUE_DT":"04/24/2007","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"745.00","CURRENT_ASSESSMENT_AMT":"745.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"1413625","VIOLATION_NO":"7548238","ISSUE_DT":"04/24/2007","CFR_STANDARD_CD":"75.604(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"1412.00","CURRENT_ASSESSMENT_AMT":"1412.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"1413624","VIOLATION_NO":"7548237","ISSUE_DT":"04/12/2007","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"286.00","CURRENT_ASSESSMENT_AMT":"286.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-04-12"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":216,"firstDate":"2004-11-03","lastDate":"2007-05-28","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":11,"validSamples":205,"maxConcentration":7.147,"concentrationTotal":114.559},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"160253","CASS_NUM":"50903220","SMP_TAKEN_DT":"5/28/2007","CONC":".11","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-28"},{"SOURCE_ROW_NUMBER":"707113","CASS_NUM":"50911306","SMP_TAKEN_DT":"5/24/2007","CONC":".089","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-24"},{"SOURCE_ROW_NUMBER":"1296108","CASS_NUM":"50903199","SMP_TAKEN_DT":"5/18/2007","CONC":".083","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-18"},{"SOURCE_ROW_NUMBER":"1341238","CASS_NUM":"50903191","SMP_TAKEN_DT":"5/17/2007","CONC":".058","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-17"},{"SOURCE_ROW_NUMBER":"1656098","CASS_NUM":"50911309","SMP_TAKEN_DT":"5/16/2007","CONC":".094","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-16"},{"SOURCE_ROW_NUMBER":"1141214","CASS_NUM":"50903188","SMP_TAKEN_DT":"5/15/2007","CONC":".247","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-15"},{"SOURCE_ROW_NUMBER":"593818","CASS_NUM":"50903195","SMP_TAKEN_DT":"5/14/2007","CONC":".11","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-05-14"},{"SOURCE_ROW_NUMBER":"1643895","CASS_NUM":"57703890","SMP_TAKEN_DT":"4/19/2007","CONC":".576","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"1553931","CASS_NUM":"57703884","SMP_TAKEN_DT":"4/19/2007","CONC":".054","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"1285559","CASS_NUM":"57703871","SMP_TAKEN_DT":"4/19/2007","CONC":".54","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"1028767","CASS_NUM":"57703885","SMP_TAKEN_DT":"4/19/2007","CONC":".734","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"919210","CASS_NUM":"57703869","SMP_TAKEN_DT":"4/19/2007","CONC":".664","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-04-19"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":45,"firstDate":"2006-05-26","lastDate":"2006-10-27","metrics":{"linkedIssuances":45},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":288,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":43,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":2,"firstDate":"2004-05-06","lastDate":"2004-05-06","metrics":{"recentRows":0,"currentOperatorTenures":2,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":23,"firstDate":"2004-05-26","lastDate":"2007-10-03","metrics":{"inspectors":45,"recentRows":0,"onSiteHours":888.5,"inspectionHours":1376.25,"inspectionSamples":74},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"634168","EVENT_NO":"4201735","INSPECTION_BEGIN_DT":"10/03/2007","INSPECTION_END_DT":"10/23/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2007-10-03"},{"SOURCE_ROW_NUMBER":"575164","EVENT_NO":"4201757","INSPECTION_BEGIN_DT":"09/12/2007","INSPECTION_END_DT":"09/27/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1.75","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2007-09-12"},{"SOURCE_ROW_NUMBER":"503773","EVENT_NO":"4438203","INSPECTION_BEGIN_DT":"07/05/2007","INSPECTION_END_DT":"07/08/2007","ACTIVITY_CODE":"E02","ACTIVITY":"103(i) Spot Inspections","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2007-07-05"},{"SOURCE_ROW_NUMBER":"505046","EVENT_NO":"4438421","INSPECTION_BEGIN_DT":"04/02/2007","INSPECTION_END_DT":"06/19/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"99","SUM_TOTAL_ON_SITE_HOURS":"55.75","sourceDate":"2007-04-02"},{"SOURCE_ROW_NUMBER":"987860","EVENT_NO":"4182353","INSPECTION_BEGIN_DT":"03/19/2007","INSPECTION_END_DT":"03/30/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"83.5","SUM_TOTAL_ON_SITE_HOURS":"49.25","sourceDate":"2007-03-19"},{"SOURCE_ROW_NUMBER":"708877","EVENT_NO":"4438189","INSPECTION_BEGIN_DT":"02/01/2007","INSPECTION_END_DT":"02/08/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2007-02-01"},{"SOURCE_ROW_NUMBER":"456547","EVENT_NO":"4438180","INSPECTION_BEGIN_DT":"10/02/2006","INSPECTION_END_DT":"12/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"107.25","SUM_TOTAL_ON_SITE_HOURS":"60","sourceDate":"2006-10-02"},{"SOURCE_ROW_NUMBER":"172445","EVENT_NO":"4227413","INSPECTION_BEGIN_DT":"08/10/2006","INSPECTION_END_DT":"08/11/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2006-08-10"},{"SOURCE_ROW_NUMBER":"940273","EVENT_NO":"4438170","INSPECTION_BEGIN_DT":"07/11/2006","INSPECTION_END_DT":"09/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"97.75","SUM_TOTAL_ON_SITE_HOURS":"75.5","sourceDate":"2006-07-11"},{"SOURCE_ROW_NUMBER":"285215","EVENT_NO":"4227484","INSPECTION_BEGIN_DT":"04/10/2006","INSPECTION_END_DT":"06/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"121.5","SUM_TOTAL_ON_SITE_HOURS":"91","sourceDate":"2006-04-10"},{"SOURCE_ROW_NUMBER":"203444","EVENT_NO":"4227388","INSPECTION_BEGIN_DT":"01/10/2006","INSPECTION_END_DT":"03/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"96.5","SUM_TOTAL_ON_SITE_HOURS":"65","sourceDate":"2006-01-10"},{"SOURCE_ROW_NUMBER":"133867","EVENT_NO":"4227380","INSPECTION_BEGIN_DT":"10/03/2005","INSPECTION_END_DT":"12/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"106.5","SUM_TOTAL_ON_SITE_HOURS":"77","sourceDate":"2005-10-03"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":19,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q4":{"hours":0,"employees":0,"production":0},"2007-Q3":{"hours":0,"employees":0,"production":0},"2007-Q2":{"hours":5657,"employees":18,"production":18131},"2007-Q1":{"hours":7685,"employees":18,"production":27321},"2006-Q4":{"hours":9330,"employees":19,"production":25545},"2006-Q3":{"hours":12462,"employees":23,"production":23550},"2006-Q2":{"hours":9669,"employees":23,"production":28795},"2006-Q1":{"hours":10670,"employees":21,"production":31090},"2005-Q2":{"hours":0,"employees":0,"production":0},"2005-Q1":{"hours":0,"employees":0,"production":0},"2004-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006":{"hours":42131,"employees":21,"production":108980},"2007":{"hours":13342,"employees":18,"production":45452}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":7,"firstDate":"2005-05-11","lastDate":"2006-10-31","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":269,"pelDoseTotal":143},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"85231","EVENT_NO":"4438180","SURVEY_DATE":"10/31/2006","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"20","PEL_DOSE_90":"8","SURVEY_TYPE":"I","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"85230","EVENT_NO":"4438180","SURVEY_DATE":"10/31/2006","OCCUPATION_CD_DESC":"BELT MAN/CONVEYOR MAN","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"40","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2006-10-31"},{"SOURCE_ROW_NUMBER":"85229","EVENT_NO":"4227284","SURVEY_DATE":"05/11/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"47","PEL_DOSE_90":"20","SURVEY_TYPE":"I","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"85228","EVENT_NO":"4227284","SURVEY_DATE":"05/11/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"29","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"85227","EVENT_NO":"4227284","SURVEY_DATE":"05/11/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"42","PEL_DOSE_90":"17","SURVEY_TYPE":"I","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"85226","EVENT_NO":"4227284","SURVEY_DATE":"05/11/2005","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"100","ACT_DOSE_85":"30","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2005-05-11"},{"SOURCE_ROW_NUMBER":"85225","EVENT_NO":"4227284","SURVEY_DATE":"05/11/2005","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"028","ACT_DOSE_85":"61","PEL_DOSE_90":"40","SURVEY_TYPE":"I","sourceDate":"2005-05-11"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":13,"firstDate":"2004-11-03","lastDate":"2007-04-19","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":4.6,"validSamples":13,"quartzPctTotal":35.2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"154603","CASSETTE_NO":"57703870","SAMPLE_DT":"04/19/2007","QUARTZ_PCT":"04.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"119140","CASSETTE_NO":"57703869","SAMPLE_DT":"04/19/2007","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-04-19"},{"SOURCE_ROW_NUMBER":"20210","CASSETTE_NO":"57634209","SAMPLE_DT":"06/28/2006","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-28"},{"SOURCE_ROW_NUMBER":"161803","CASSETTE_NO":"57612034","SAMPLE_DT":"02/27/2006","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-27"},{"SOURCE_ROW_NUMBER":"114838","CASSETTE_NO":"57611988","SAMPLE_DT":"02/27/2006","QUARTZ_PCT":"04.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-27"},{"SOURCE_ROW_NUMBER":"51305","CASSETTE_NO":"57611936","SAMPLE_DT":"02/27/2006","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-02-27"},{"SOURCE_ROW_NUMBER":"130676","CASSETTE_NO":"57588784","SAMPLE_DT":"10/12/2005","QUARTZ_PCT":"04.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-10-12"},{"SOURCE_ROW_NUMBER":"56560","CASSETTE_NO":"57588781","SAMPLE_DT":"10/12/2005","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-10-12"},{"SOURCE_ROW_NUMBER":"150601","CASSETTE_NO":"57588816","SAMPLE_DT":"08/17/2005","QUARTZ_PCT":"01.2","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-17"},{"SOURCE_ROW_NUMBER":"72279","CASSETTE_NO":"57588808","SAMPLE_DT":"08/17/2005","QUARTZ_PCT":"02.6","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-17"},{"SOURCE_ROW_NUMBER":"38253","CASSETTE_NO":"57588807","SAMPLE_DT":"08/17/2005","QUARTZ_PCT":"03.3","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-17"},{"SOURCE_ROW_NUMBER":"49554","CASSETTE_NO":"57537333","SAMPLE_DT":"12/27/2004","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-12-27"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":263,"firstDate":"2004-08-23","lastDate":"2007-07-05","metrics":{"ss":126,"amountDue":40142,"contested":0,"amountPaid":990.07,"recentRows":0,"section104d":5,"unterminated":1,"proposedPenalty":40142},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1056929","VIOLATION_NO":"7444433","VIOLATION_ISSUE_DT":"07/05/2007","PART_SECTION":"75.403","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"08/27/2013","CONTESTED_IND":"N","sourceDate":"2007-07-05"},{"SOURCE_ROW_NUMBER":"1056853","VIOLATION_NO":"7548267","VIOLATION_ISSUE_DT":"06/07/2007","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","PROPOSED_PENALTY":"317","AMOUNT_DUE":"317","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-06-07"},{"SOURCE_ROW_NUMBER":"1056842","VIOLATION_NO":"7423673","VIOLATION_ISSUE_DT":"05/07/2007","SIG_SUB":"N","PART_SECTION":"75.312(e)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/07/2007","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-07"},{"SOURCE_ROW_NUMBER":"1056841","VIOLATION_NO":"7423672","VIOLATION_ISSUE_DT":"05/07/2007","SIG_SUB":"N","PART_SECTION":"75.1202-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/09/2007","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-07"},{"SOURCE_ROW_NUMBER":"1056840","VIOLATION_NO":"7423671","VIOLATION_ISSUE_DT":"05/07/2007","SIG_SUB":"N","PART_SECTION":"75.360(f)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/07/2007","PROPOSED_PENALTY":"190","AMOUNT_DUE":"190","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-05-07"},{"SOURCE_ROW_NUMBER":"1056852","VIOLATION_NO":"7548244","VIOLATION_ISSUE_DT":"04/30/2007","SIG_SUB":"N","PART_SECTION":"77.1606(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2007","PROPOSED_PENALTY":"243","AMOUNT_DUE":"243","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1056851","VIOLATION_NO":"7548243","VIOLATION_ISSUE_DT":"04/30/2007","SIG_SUB":"N","PART_SECTION":"75.342(a)(4)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2007","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1056850","VIOLATION_NO":"7548242","VIOLATION_ISSUE_DT":"04/30/2007","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2007","PROPOSED_PENALTY":"585","AMOUNT_DUE":"585","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1056849","VIOLATION_NO":"7548241","VIOLATION_ISSUE_DT":"04/30/2007","SIG_SUB":"N","PART_SECTION":"75.523-3(b)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/30/2007","PROPOSED_PENALTY":"224","AMOUNT_DUE":"224","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-04-30"},{"SOURCE_ROW_NUMBER":"1056848","VIOLATION_NO":"7548240","VIOLATION_ISSUE_DT":"04/24/2007","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/07/2007","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"1056847","VIOLATION_NO":"7548239","VIOLATION_ISSUE_DT":"04/24/2007","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/24/2007","PROPOSED_PENALTY":"745","AMOUNT_DUE":"745","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-04-24"},{"SOURCE_ROW_NUMBER":"1056846","VIOLATION_NO":"7548238","VIOLATION_ISSUE_DT":"04/24/2007","SIG_SUB":"Y","PART_SECTION":"75.604(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/24/2007","PROPOSED_PENALTY":"1412","AMOUNT_DUE":"1412","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2007-04-24"}]}],"safety":{"href":"/api/v1/mines/1518753/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518753/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":2},{"chapter":"I","heading":"Main mine fan examinations and records.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.312","part":"75","subchapter":"O","subpart":"D","id":"75.312","citation":"30 CFR 75.312","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Temporary notations, revisions, and supplements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1202-1","part":"75","subchapter":"O","subpart":"M","id":"75.1202-1","citation":"30 CFR 75.1202-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.360","heading":"Preshift examination at fixed intervals.","id":"75.360","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.360","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) Except as provided in paragraph (a)(2) of this section, a certified person designated by the operator must make a preshift examination within 3 hours preceding the beginning of any 8-hour interval during which any person is scheduled to work or travel underground. No person other than certified examiners may enter or remain in any underground area unless a preshift examination has been completed for the established 8-hour interval. The operator must establish 8-hour intervals of time subject to the required preshift examinations.\n\n(2) Preshift examinations of areas where pumpers are scheduled to work or travel shall not be required prior to the pumper entering the areas if the pumper is a certified person and the pumper conducts an examination for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, tests for methane and oxygen deficiency, and determines if the air is moving in its proper direction in the area where the pumper works or travels. The examination of the area must be completed before the pumper performs any other work. A record of all hazardous conditions and violations of the mandatory health or safety standards found by the pumper shall be made and retained in accordance with § 75.363 of this part.\n\n(b) The person conducting the preshift examination shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (b)(11) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction at the following locations:\n\n(1) Roadways, travelways and track haulageways where persons are scheduled, prior to the beginning of the preshift examination, to work or travel during the oncoming shift.\n\n(2) Belt conveyors that will be used to transport persons during the oncoming shift and the entries in which these belt conveyors are located.\n\n(3) Working sections and areas where mechanized mining equipment is being installed or removed, if anyone is scheduled to work on the section or in the area during the oncoming shift. The scope of the examination shall include the working places, approaches to worked-out areas and ventilation controls on these sections and in these areas, and the examination shall include tests of the roof, face and rib conditions on these sections and in these areas.\n\n(4) Approaches to worked-out areas along intake air courses and at the entries used to carry air into worked-out areas if the intake air passing the approaches is used to ventilate working sections where anyone is scheduled to work during the oncoming shift. The examination of the approaches to the worked-out areas shall be made in the intake air course immediately inby and outby each entry used to carry air into the worked-out area. An examination of the entries used to carry air into the worked-out areas shall be conducted at a point immediately inby the intersection of each entry with the intake air course.\n\n(5) Seals along intake air courses where intake air passes by a seal to ventilate working sections where anyone is scheduled to work during the oncoming shift.\n\n(6)(i) Entries and rooms developed after November 15, 1992, and developed more than 2 crosscuts off an intake air course without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift; and,\n\n(ii) Entries and rooms developed after November 15, 1992, and driven more than 20 feet off an intake air course without a crosscut and without permanent ventilation controls where intake air passes through or by these entries or rooms to reach a working section where anyone is scheduled to work during the oncoming shift.\n\n(7) Areas where trolley wires or trolley feeder wires are to be or will remain energized during the oncoming shift.\n\n(8) High spots along intake air courses where methane is likely to accumulate, if equipment will be operated in the area during the shift.\n\n(9) Underground electrical installations referred to in § 75.340(a), except those pumps listed in § 75.340 (b)(2) through (b)(6), and areas where compressors subject to § 75.344 are installed if the electrical installation or compressor is or will be energized during the shift.\n\n(10) Other areas where work or travel during the oncoming shift is scheduled prior to the beginning of the preshift examination.\n\n(11) Preshift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(c) The person conducting the preshift examination shall determine the volume of air entering each of the following areas if anyone is scheduled to work in the areas during the oncoming shift:\n\n(1) In the last open crosscut of each set of entries or rooms on each working section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) On each longwall or shortwall in the intake entry or entries at the intake end of the longwall or shortwall face immediately outby the face and the velocity of air at each end of the face at the locations specified in the approved ventilation plan.\n\n(3) At the intake end of any pillar line—\n\n(i) If a single split of air is used, in the intake entry furthest from the return air course, immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) If a split system is used, in the intake entries of each split immediately inby the split point.\n\n(d) The person conducting the preshift examination shall check the refuge alternative for damage, the integrity of the tamper-evident seal and the mechanisms required to deploy the refuge alternative, and the ready availability of compressed oxygen and air.\n\n(e) The district manager may require the operator to examine other areas of the mine or examine for other hazards and violations of other mandatory health or safety standards found during the preshift examination.\n\n(f) Certification. At each working place examined, the person doing the preshift examination shall certify by initials, date, and the time, that the examination was made. In areas required to be examined outby a working section, the certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(g) Recordkeeping. A record of the results of each preshift examination, including a record of hazardous conditions and violations of the nine mandatory health or safety standards and their locations found by the examiner during each examination, and of the results and locations of air and methane measurements, shall be made on the surface before any persons, other than certified persons conducting examinations required by this subpart, enter any underground area of the mine. The results of methane tests shall be recorded as the percentage of methane measured by the examiner. The record shall be made by the certified person who made the examination or by a person designated by the operator. If the record is made by someone other than the examiner, the examiner shall verify the record by initials and date by or at the end of the shift for which the examination was made. A record shall also be made by a certified person of the action taken to correct hazardous conditions and violations of mandatory health or safety standards found during the preshift examination. All preshift and corrective action records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The records required by this section shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(h) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 62 FR 35085, June 30, 1997; 64 FR 45170, Aug. 19, 1999; 73 FR 80697, Dec. 31, 2008; 77 FR 20714, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1606","heading":"Loading and haulage equipment; inspection and maintenance.","id":"77.1606","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1606","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Mobile loading and haulage equipment shall be inspected by a competent person before such equipment is placed in operation. Equipment defects affecting safety shall be recorded and reported to the mine operator.\n\n(b) Carriers on aerial tramways, including loading and unloading mechanisms, shall be inspected each shift; brakes shall be inspected daily; ropes and supports shall be inspected as recommended by the manufacturer or as physical conditions warrant. Equipment defects affecting safety shall be reported to the mine operator.\n\n(c) Equipment defects affecting safety shall be corrected before the equipment is used.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.342","heading":"Methane monitors.","id":"75.342","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.342","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) MSHA approved methane monitors shall be installed on all face cutting machines, continuous miners, longwall face equipment, loading machines, and other mechanized equipment used to extract or load coal within the working place.\n\n(2) The sensing device for methane monitors on longwall shearing machines shall be installed at the return air end of the longwall face. An additional sensing device also shall be installed on the longwall shearing machine, downwind and as close to the cutting head as practicable. An alternative location or locations for the sensing device required on the longwall shearing machine may be approved in the ventilation plan.\n\n(3) The sensing devices of methane monitors shall be installed as close to the working face as practicable.\n\n(4) Methane monitors shall be maintained in permissible and proper operating condition and shall be calibrated with a known air-methane mixture at least once every 31 days. To assure that methane monitors are properly maintained and calibrated, the operator shall:\n\n(i) Use persons properly trained in the maintenance, calibration, and permissibility of methane monitors to calibrate and maintain the devices.\n\n(ii) Maintain a record of all calibration tests of methane monitors. Records shall be maintained in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(iii) Retain the record of calibration tests for 1 year from the date of the test. Records shall be retained at a surface location at the mine and made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(b)(1) When the methane concentration at any methane monitor reaches 1.0 percent the monitor shall give a warning signal.\n\n(2) The warning signal device of the methane monitor shall be visible to a person who can deenergize electric equipment or shut down diesel-powered equipment on which the monitor is mounted.\n\n(c) The methane monitor shall automatically deenergize electric equipment or shut down diesel-powered equipment on which it is mounted when—\n\n(1) The methane concentration at any methane monitor reaches 2.0 percent; or\n\n(2) The monitor is not operating properly.\n\n[61 FR 9829, Mar. 11, 1996, as amended at 61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.523-3","heading":"Automatic emergency-parking brakes.","id":"75.523-3","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.523-3","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.\n\n(1) On and after May 23, 1989—\n\n(i) All new equipment ordered; and\n\n(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.\n\n(2) On and after May 23, 1991, all other equipment.\n\n(b) Automatic emergency-parking brakes shall—\n\n(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;\n\n(2) Engage automatically within 5.0 seconds when the equipment is deenergized;\n\n(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;\n\n(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and\n\n(5) Release only by a manual control that does not operate any other equipment function.\n\n(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to—\n\n(1) Apply the brakes manually without deenergizing the equipment; and\n\n(2) Release and reengage the brakes without energizing the equipment.\n\n(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary—\n\n(1) On the maximum grade on which it is operated; and\n\n(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.\n\n(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equipment.\n\n[54 FR 12412, Mar. 24, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.604","heading":"Permanent splicing of trailing cables.","id":"75.604","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-G/section-75.604","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"G","subpartHeading":"Subpart G—Trailing Cables","text":"[Statutory Provisions]\n\nWhen permanent splices in trailing cables are made, they shall be:\n\n(a) Mechanically strong with adequate electrical conductivity and flexibility;\n\n(b) Effectively insulated and sealed so as to exclude moisture; and\n\n(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.\n\n(d) Made using splice kits accepted or approved by MSHA as flame resistant.\n\n[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518753","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}