{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518733","name":"#1","status":"Abandoned and Sealed","status_date":"2006-11-03","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Eastern","operator_id":"0053996","operator_name":"Black Gem Coal Sales Inc","controller_id":"C15570","controller_name":"Clark D  Pergrem","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.516944,"longitude":-82.811388},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":466},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518733","name":"#1"},"operator":{"type":"operator","id":"0053996","name":"Black Gem Coal Sales Inc"},"controller":{"type":"controller","id":"C15570","name":"Clark D  Pergrem"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15704","name":"Brian  Jones"},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2002-09-04","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|C15704|2002-09-04|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050919","name":"Dennis Mining LLC"},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2004-03-19","validTo":"2004-07-28","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0050919|2004-03-19|2004-07-28"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15704","name":"Brian  Jones"},"object":{"type":"operator","id":"0050919","name":"Dennis Mining LLC"},"validFrom":"2004-03-19","validTo":"2004-07-28","current":false,"derived":true,"evidenceMineId":"1518733","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0050919|2004-03-19|C15704|2002-09-04|96576"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0053452","name":"Green River Mining Company Inc."},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2004-07-29","validTo":"2005-06-22","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0053452|2004-07-29|2005-06-22"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0044205","name":"Golden  Sandlin et al"},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2004-07-29","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0044205|2004-07-29|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0044205","name":"Golden  Sandlin et al"},"object":{"type":"operator","id":"0053452","name":"Green River Mining Company Inc."},"validFrom":"2004-07-29","validTo":"2005-06-22","current":false,"derived":true,"evidenceMineId":"1518733","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0053452|2004-07-29|0044205|2004-07-29|4940"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15570","name":"Clark D  Pergrem"},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2004-09-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|C15570|2004-09-08|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0060763","name":"Double E Mining LLC"},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2005-06-23","validTo":"2005-12-07","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0060763|2005-06-23|2005-12-07"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0050689","name":"Earl Ray  Lawson"},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2005-06-23","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0050689|2005-06-23|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0050689","name":"Earl Ray  Lawson"},"object":{"type":"operator","id":"0060763","name":"Double E Mining LLC"},"validFrom":"2005-06-23","validTo":"2005-12-07","current":false,"derived":true,"evidenceMineId":"1518733","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0060763|2005-06-23|0050689|2005-06-23|6369"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0053996","name":"Black Gem Coal Sales Inc"},"object":{"type":"mine","id":"1518733","name":"#1"},"validFrom":"2005-12-08","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0053996|2005-12-08|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15570","name":"Clark D  Pergrem"},"object":{"type":"operator","id":"0053996","name":"Black Gem Coal Sales Inc"},"validFrom":"2005-12-08","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518733","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518733|0053996|2005-12-08|C15570|2004-09-08|96228"}}],"coverage":{"historyRecords":4,"edgeCount":12,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":5,"firstDate":"2004-11-06","lastDate":"2006-05-01","metrics":{"daysLost":16,"injuries":5,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"78946","DOCUMENT_NO":"220061280045","ACCIDENT_DT":"05/01/2006","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Coal dump operator","NO_INJURIES":"1","DAYS_LOST":"2","NARRATIVE":"Employee was working dump. Cutter man was pulling cable up and accidentally pulled cable down on employee's back and shoulder.","sourceDate":"2006-05-01"},{"SOURCE_ROW_NUMBER":"139125","DOCUMENT_NO":"220060810052","ACCIDENT_DT":"03/13/2006","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Struck by falling object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"While pinner man was bolting top a small piece of rock hit him in the right eye causing a small scratch on his right eye.","sourceDate":"2006-03-13"},{"SOURCE_ROW_NUMBER":"203625","DOCUMENT_NO":"220051680011","ACCIDENT_DT":"06/06/2005","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Discontinued 1/31/2014.  Several other codes cover Scoop Car Operator","NO_INJURIES":"1","DAYS_LOST":"4","NARRATIVE":"Employee was cleaning loose coal off coal rib when the scoop went wide open and slammed into the right side of rib, lacerating employee above right eye and causing mild whiplash.","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"177875","DOCUMENT_NO":"220050070009","ACCIDENT_DT":"12/29/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Caught in, under or between NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"Employee was roof bolting when he caught his left thumb between the steel, breaking and bruising the skin along the left side of the thumb.","sourceDate":"2004-12-29"},{"SOURCE_ROW_NUMBER":"242484","DOCUMENT_NO":"220043270033","ACCIDENT_DT":"11/06/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"BENDING A ROOF BOLT AND PULLED A MUSCLE IN HIS BACK.","sourceDate":"2004-11-06"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2006-11-03","lastDate":"2006-11-03","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":147,"firstDate":"2004-06-03","lastDate":"2006-06-30","metrics":{"ss":75,"delinquent":146,"recentRows":0,"paidPenalty":9987,"proposedPenalty":13638,"currentAssessment":13638},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1018116","VIOLATION_NO":"7433856","ISSUE_DT":"06/30/2006","CFR_STANDARD_CD":"75.1711-3","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-30"},{"SOURCE_ROW_NUMBER":"1018115","VIOLATION_NO":"7433159","ISSUE_DT":"04/12/2006","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-12"},{"SOURCE_ROW_NUMBER":"1018096","VIOLATION_NO":"7433156","ISSUE_DT":"04/05/2006","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-04-05"},{"SOURCE_ROW_NUMBER":"1016854","VIOLATION_NO":"7433200","ISSUE_DT":"03/20/2006","CFR_STANDARD_CD":"77.1605(k)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"84.00","CURRENT_ASSESSMENT_AMT":"84.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-20"},{"SOURCE_ROW_NUMBER":"1016853","VIOLATION_NO":"7433198","ISSUE_DT":"03/14/2006","CFR_STANDARD_CD":"75.333(e)(1)(ii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-14"},{"SOURCE_ROW_NUMBER":"1016852","VIOLATION_NO":"7433197","ISSUE_DT":"03/14/2006","CFR_STANDARD_CD":"75.520","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"84.00","CURRENT_ASSESSMENT_AMT":"84.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-14"},{"SOURCE_ROW_NUMBER":"1016851","VIOLATION_NO":"7433196","ISSUE_DT":"03/14/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-14"},{"SOURCE_ROW_NUMBER":"1016850","VIOLATION_NO":"7433193","ISSUE_DT":"03/09/2006","CFR_STANDARD_CD":"75.362(d)(1)(ii)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-09"},{"SOURCE_ROW_NUMBER":"1016849","VIOLATION_NO":"7433192","ISSUE_DT":"03/09/2006","CFR_STANDARD_CD":"75.362(d)(2)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-09"},{"SOURCE_ROW_NUMBER":"1016848","VIOLATION_NO":"7433191","ISSUE_DT":"03/07/2006","CFR_STANDARD_CD":"75.333(c)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"144.00","CURRENT_ASSESSMENT_AMT":"144.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"1016847","VIOLATION_NO":"7433190","ISSUE_DT":"03/07/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"84.00","CURRENT_ASSESSMENT_AMT":"84.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"1016846","VIOLATION_NO":"7433189","ISSUE_DT":"03/07/2006","CFR_STANDARD_CD":"75.403","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-07"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":85,"firstDate":"2004-06-28","lastDate":"2006-04-27","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":6,"validSamples":79,"maxConcentration":12.54,"concentrationTotal":69.498},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1249185","CASS_NUM":"50795848","SMP_TAKEN_DT":"4/27/2006","CONC":"9.165","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-27"},{"SOURCE_ROW_NUMBER":"1236931","CASS_NUM":"50808076","SMP_TAKEN_DT":"4/26/2006","CONC":"12.54","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-04-26"},{"SOURCE_ROW_NUMBER":"823338","CASS_NUM":"50808046","SMP_TAKEN_DT":"3/24/2006","CONC":"4.483","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-24"},{"SOURCE_ROW_NUMBER":"1622013","CASS_NUM":"57627093","SMP_TAKEN_DT":"3/16/2006","CONC":".287","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"947586","CASS_NUM":"57627116","SMP_TAKEN_DT":"3/16/2006","CONC":".613","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"776370","CASS_NUM":"57627098","SMP_TAKEN_DT":"3/16/2006","CONC":"1.539","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"632948","CASS_NUM":"57627108","SMP_TAKEN_DT":"3/16/2006","CONC":".31","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"589255","CASS_NUM":"57627115","SMP_TAKEN_DT":"3/16/2006","CONC":".34","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CUTTING MACHINE OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"370184","CASS_NUM":"57627074","SMP_TAKEN_DT":"3/16/2006","CONC":".133","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"304548","CASS_NUM":"57627038","SMP_TAKEN_DT":"3/16/2006","CONC":"1.033","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"831132","CASS_NUM":"57575613","SMP_TAKEN_DT":"9/8/2005","CONC":".685","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-08"},{"SOURCE_ROW_NUMBER":"681374","CASS_NUM":"57575564","SMP_TAKEN_DT":"9/8/2005","CONC":".314","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-09-08"}]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2004-03-19","lastDate":"2005-12-08","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":3},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":26,"firstDate":"2004-03-25","lastDate":"2006-08-07","metrics":{"inspectors":36,"recentRows":0,"onSiteHours":459.5,"inspectionHours":652.5,"inspectionSamples":20},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1156832","EVENT_NO":"4189586","INSPECTION_BEGIN_DT":"08/07/2006","INSPECTION_END_DT":"08/07/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2006-08-07"},{"SOURCE_ROW_NUMBER":"448691","EVENT_NO":"4189579","INSPECTION_BEGIN_DT":"07/20/2006","INSPECTION_END_DT":"07/20/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2006-07-20"},{"SOURCE_ROW_NUMBER":"280067","EVENT_NO":"4189567","INSPECTION_BEGIN_DT":"04/12/2006","INSPECTION_END_DT":"06/30/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"12.5","sourceDate":"2006-04-12"},{"SOURCE_ROW_NUMBER":"738434","EVENT_NO":"4189565","INSPECTION_BEGIN_DT":"04/05/2006","INSPECTION_END_DT":"04/05/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2006-04-05"},{"SOURCE_ROW_NUMBER":"199541","EVENT_NO":"4189287","INSPECTION_BEGIN_DT":"03/29/2006","INSPECTION_END_DT":"03/29/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6.5","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"1020100","EVENT_NO":"4189280","INSPECTION_BEGIN_DT":"02/15/2006","INSPECTION_END_DT":"03/20/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"55.5","SUM_TOTAL_ON_SITE_HOURS":"40","sourceDate":"2006-02-15"},{"SOURCE_ROW_NUMBER":"218935","EVENT_NO":"4189268","INSPECTION_BEGIN_DT":"10/18/2005","INSPECTION_END_DT":"12/07/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"13","SUM_TOTAL_ON_SITE_HOURS":"6.5","sourceDate":"2005-10-18"},{"SOURCE_ROW_NUMBER":"145031","EVENT_NO":"4189082","INSPECTION_BEGIN_DT":"10/06/2005","INSPECTION_END_DT":"10/06/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2005-10-06"},{"SOURCE_ROW_NUMBER":"482043","EVENT_NO":"4189077","INSPECTION_BEGIN_DT":"07/06/2005","INSPECTION_END_DT":"09/26/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"106.5","SUM_TOTAL_ON_SITE_HOURS":"79","sourceDate":"2005-07-06"},{"SOURCE_ROW_NUMBER":"529530","EVENT_NO":"5809311","INSPECTION_BEGIN_DT":"06/28/2005","INSPECTION_END_DT":"06/28/2005","ACTIVITY_CODE":"E19","ACTIVITY":"Electrical Technical Investigation","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2005-06-28"},{"SOURCE_ROW_NUMBER":"204890","EVENT_NO":"4189066","INSPECTION_BEGIN_DT":"04/18/2005","INSPECTION_END_DT":"06/02/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"25","SUM_TOTAL_ON_SITE_HOURS":"13.5","sourceDate":"2005-04-18"},{"SOURCE_ROW_NUMBER":"532002","EVENT_NO":"4189057","INSPECTION_BEGIN_DT":"02/04/2005","INSPECTION_END_DT":"03/21/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2005-02-04"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":28,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q4":{"hours":0,"employees":0,"production":0},"2006-Q3":{"hours":0,"employees":0,"production":0},"2006-Q2":{"hours":5413,"employees":22,"production":5056},"2006-Q1":{"hours":2943,"employees":15,"production":3919},"2005-Q4":{"hours":0,"employees":0,"production":0},"2005-Q3":{"hours":0,"employees":0,"production":0},"2005-Q2":{"hours":4718,"employees":23,"production":7670},"2005-Q1":{"hours":9788,"employees":23,"production":23598},"2004-Q4":{"hours":8733,"employees":19,"production":0},"2004-Q3":{"hours":2900,"employees":14,"production":5900}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":7,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":11633,"employees":18,"production":5900},"2005":{"hours":14506,"employees":25,"production":31268},"2006":{"hours":8356,"employees":19,"production":8975}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":10,"firstDate":"2004-11-02","lastDate":"2006-03-16","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":450,"pelDoseTotal":295},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"84720","EVENT_NO":"4189280","SURVEY_DATE":"03/16/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"45","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"84719","EVENT_NO":"4189280","SURVEY_DATE":"03/16/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"50","PEL_DOSE_90":"21","SURVEY_TYPE":"I","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"84718","EVENT_NO":"4189280","SURVEY_DATE":"03/16/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"27","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"84717","EVENT_NO":"4189280","SURVEY_DATE":"03/16/2006","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"49","PEL_DOSE_90":"22","SURVEY_TYPE":"I","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"84716","EVENT_NO":"4189280","SURVEY_DATE":"03/16/2006","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"30","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2006-03-16"},{"SOURCE_ROW_NUMBER":"84715","EVENT_NO":"4185005","SURVEY_DATE":"11/02/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"71","PEL_DOSE_90":"62","SURVEY_TYPE":"I","sourceDate":"2004-11-02"},{"SOURCE_ROW_NUMBER":"84714","EVENT_NO":"4185005","SURVEY_DATE":"11/02/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"35","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2004-11-02"},{"SOURCE_ROW_NUMBER":"84713","EVENT_NO":"4185005","SURVEY_DATE":"11/02/2004","OCCUPATION_CD_DESC":"BLASTER/SHOOTER/SHOTFIRER","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"22","PEL_DOSE_90":"16","SURVEY_TYPE":"I","sourceDate":"2004-11-02"},{"SOURCE_ROW_NUMBER":"84712","EVENT_NO":"4185005","SURVEY_DATE":"11/02/2004","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"067","ACT_DOSE_85":"44","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2004-11-02"},{"SOURCE_ROW_NUMBER":"84711","EVENT_NO":"4185005","SURVEY_DATE":"11/02/2004","OCCUPATION_CD_DESC":"CUTTING MACHINE OPERATOR","MACHINE_CD":"11","MANUFACTURER_CD":"058","ACT_DOSE_85":"77","PEL_DOSE_90":"64","SURVEY_TYPE":"I","sourceDate":"2004-11-02"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":4,"firstDate":"2004-11-02","lastDate":"2005-02-09","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":3.9,"validSamples":4,"quartzPctTotal":13.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"23232","CASSETTE_NO":"57577056","SAMPLE_DT":"02/09/2005","QUARTZ_PCT":"03.9","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-09"},{"SOURCE_ROW_NUMBER":"119729","CASSETTE_NO":"57577026","SAMPLE_DT":"01/18/2005","QUARTZ_PCT":"03.7","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-18"},{"SOURCE_ROW_NUMBER":"117189","CASSETTE_NO":"57576953","SAMPLE_DT":"01/18/2005","QUARTZ_PCT":"03.8","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-18"},{"SOURCE_ROW_NUMBER":"116603","CASSETTE_NO":"57492602","SAMPLE_DT":"11/02/2004","QUARTZ_PCT":"01.7","OCC_CODE_DESC":"CUTTING MACHINE OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-11-02"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":148,"firstDate":"2004-06-03","lastDate":"2006-06-30","metrics":{"ss":76,"amountDue":13638,"contested":0,"amountPaid":9987,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":13638},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1053969","VIOLATION_NO":"7433856","VIOLATION_ISSUE_DT":"06/30/2006","SIG_SUB":"N","PART_SECTION":"75.1711-3","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"08/07/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-30"},{"SOURCE_ROW_NUMBER":"1053968","VIOLATION_NO":"7433159","VIOLATION_ISSUE_DT":"04/12/2006","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"7","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/19/2006","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2006-04-12"},{"SOURCE_ROW_NUMBER":"1053967","VIOLATION_NO":"7433156","VIOLATION_ISSUE_DT":"04/05/2006","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/12/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-04-05"},{"SOURCE_ROW_NUMBER":"1053955","VIOLATION_NO":"7433200","VIOLATION_ISSUE_DT":"03/20/2006","SIG_SUB":"Y","PART_SECTION":"77.1605(k)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/29/2006","PROPOSED_PENALTY":"84","AMOUNT_DUE":"84","AMOUNT_PAID":"84","CONTESTED_IND":"N","sourceDate":"2006-03-20"},{"SOURCE_ROW_NUMBER":"1053954","VIOLATION_NO":"7433198","VIOLATION_ISSUE_DT":"03/14/2006","SIG_SUB":"N","PART_SECTION":"75.333(e)(1)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/29/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-03-14"},{"SOURCE_ROW_NUMBER":"1053953","VIOLATION_NO":"7433197","VIOLATION_ISSUE_DT":"03/14/2006","SIG_SUB":"Y","PART_SECTION":"75.520","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/16/2006","PROPOSED_PENALTY":"84","AMOUNT_DUE":"84","AMOUNT_PAID":"84","CONTESTED_IND":"N","sourceDate":"2006-03-14"},{"SOURCE_ROW_NUMBER":"1053952","VIOLATION_NO":"7433196","VIOLATION_ISSUE_DT":"03/14/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/16/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-03-14"},{"SOURCE_ROW_NUMBER":"1053951","VIOLATION_NO":"7433193","VIOLATION_ISSUE_DT":"03/09/2006","SIG_SUB":"Y","PART_SECTION":"75.362(d)(1)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/09/2006","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2006-03-09"},{"SOURCE_ROW_NUMBER":"1053950","VIOLATION_NO":"7433192","VIOLATION_ISSUE_DT":"03/09/2006","SIG_SUB":"Y","PART_SECTION":"75.362(d)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/10/2006","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2006-03-09"},{"SOURCE_ROW_NUMBER":"1053949","VIOLATION_NO":"7433191","VIOLATION_ISSUE_DT":"03/07/2006","SIG_SUB":"Y","PART_SECTION":"75.333(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/10/2006","PROPOSED_PENALTY":"144","AMOUNT_DUE":"144","AMOUNT_PAID":"144","CONTESTED_IND":"N","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"1053948","VIOLATION_NO":"7433190","VIOLATION_ISSUE_DT":"03/07/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/07/2006","PROPOSED_PENALTY":"84","AMOUNT_DUE":"84","AMOUNT_PAID":"84","CONTESTED_IND":"N","sourceDate":"2006-03-07"},{"SOURCE_ROW_NUMBER":"1053947","VIOLATION_NO":"7433189","VIOLATION_ISSUE_DT":"03/07/2006","SIG_SUB":"N","PART_SECTION":"75.403","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/10/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-03-07"}]}],"safety":{"href":"/api/v1/mines/1518733/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518733/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Openings of active mines.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1711-3","part":"75","subchapter":"O","subpart":"R","id":"75.1711-3","citation":"30 CFR 75.1711-3","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.403","heading":"Maintenance of incombustible content of rock dust.","id":"75.403","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.403","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 80 percent. Where methane is present in any ventilating current, the percent of incombustible content of such combined dust shall be increased 0.4 percent for each 0.1 percent of methane.\n\n[75 FR 57857, Sept. 23, 2010; 76 FR 35978, June 21, 2011]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":2},{"chapter":"I","heading":"Electric equipment; switches.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.520","part":"75","subchapter":"O","subpart":"F","id":"75.520","citation":"30 CFR 75.520","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.362","heading":"On-shift examination.","id":"75.362","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.362","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) At least once during each shift, or more often if necessary for safety, a certified person designated by the operator shall conduct an on-shift examination of each section where anyone is assigned to work during the shift and any area where mechanized mining equipment is being installed or removed during the shift. The certified person shall check for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section, test for methane and oxygen deficiency, and determine if the air is moving in its proper direction.\n\n(2) A person designated by the operator shall conduct an examination and record the results and the corrective actions taken to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan. In those instances when a shift change is accomplished without an interruption in production on a section, the examination shall be made anytime within 1 hour after the shift change. In those instances when there is an interruption in production during the shift change, the examination shall be made before production begins on a section. Deficiencies in dust controls shall be corrected before production begins or resumes. The examination shall include: Air quantities and velocities; water pressures and flow rates; excessive leakage in the water delivery system; water spray numbers and orientations; section ventilation and control device placement; roof bolting machine dust collector vacuum levels; scrubber air flow rate; work practices required by the ventilation plan; and any other dust suppression measures. Measurements of the air velocity and quantity, water pressure and flow rates are not required if continuous monitoring of these controls is used and indicates that the dust controls are functioning properly.\n\n(3) On-shift examinations shall include examinations to identify violations of the standards listed below:\n\n(i) §§ 75.202(a) and 75.220(a)(1)—roof control;\n\n(ii) §§ 75.333(h) and 75.370(a)(1)—ventilation, methane;\n\n(iii) §§ 75.400 and 75.403—accumulations of combustible materials and application of rock dust;\n\n(iv) § 75.1403—other safeguards, limited to maintenance of travelways along belt conveyors, off track haulage roadways, and track haulage, track switches, and other components for haulage;\n\n(v) § 75.1722(a)—guarding moving machine parts; and\n\n(vi) § 75.1731(a)—maintenance of belt conveyor components.\n\n(b) During each shift that coal is produced, a certified person shall examine for hazardous conditions and violations of the mandatory health or safety standards referenced in paragraph (a)(3) of this section along each belt conveyor haulageway where a belt conveyor is operated. This examination may be conducted at the same time as the preshift examination of belt conveyors and belt conveyor haulageways, if the examination is conducted within 3 hours before the oncoming shift.\n\n(c) Persons conducting the on-shift examination shall determine at the following locations:\n\n(1) The volume of air in the last open crosscut of each set of entries or rooms on each section and areas where mechanized mining equipment is being installed or removed. The last open crosscut is the crosscut in the line of pillars containing the permanent stoppings that separate the intake air courses and the return air courses.\n\n(2) The volume of air on a longwall or shortwall, including areas where longwall or shortwall equipment is being installed or removed, in the intake entry or entries at the intake end of the longwall or shortwall.\n\n(3) The velocity of air at each end of the longwall or shortwall face at the locations specified in the approved ventilation plan.\n\n(4) The volume of air at the intake end of any pillar line—\n\n(i) Where a single split of air is used in the intake entry furthest from the return air course immediately outby the first open crosscut outby the line of pillars being mined; or\n\n(ii) Where a split system is used in the intake entries of each split immediately inby the split point.\n\n(d) (1) A qualified person shall make tests for methane—\n\n(i) At the start of each shift at each working place before electrically operated equipment is energized; and\n\n(ii) Immediately before equipment is energized, taken into, or operated in a working place; and\n\n(iii) At 20-minute intervals, or more often if required in the approved ventilation plan at specific locations, during the operation of equipment in the working place.\n\n(2) Except as provided for in paragraph (d)(3) of this section, these methane tests shall be made at the face from under permanent roof support, using extendable probes or other acceptable means. When longwall or shortwall mining systems are used, these methane tests shall be made at the shearer, the plow, or the cutting head. When mining has been stopped for more than 20 minutes, methane tests shall be conducted prior to the start up of equipment.\n\n(3) As an alternative method of compliance with paragraph (d)(2) of this section during roof bolting, methane tests may be made by sweeping an area not less than 16 feet inby the last area of permanently supported roof, using a probe or other acceptable means. This method of testing is conditioned on meeting the following requirements:\n\n(i) The roof bolting machine must be equipped with an integral automated temporary roof support (ATRS) system that meets the requirements of 30 CFR 75.209.\n\n(ii) The roof bolting machine must have a permanently mounted, MSHA-approved methane monitor which meets the maintenance and calibration requirements of 30 CFR 75.342(a)(4), the warning signal requirements of 30 CFR 75.342(b), and the automatic de-energization requirements of 30 CFR 75.342(c).\n\n(iii) The methane monitor sensor must be mounted near the inby end and within 18 inches of the longitudinal center of the ATRS support, and positioned at least 12 inches from the roof when the ATRS is fully deployed.\n\n(iv) Manual methane tests must be made at intervals not exceeding 20 minutes. The test may be made either from under permanent roof support or from the roof bolter's work position protected by the deployed ATRS.\n\n(v) Once a methane test is made at the face, all subsequent methane tests in the same area of unsupported roof must also be made at the face, from under permanent roof support, using extendable probes or other acceptable means at intervals not exceeding 20 minutes.\n\n(vi) The district manager may require that the ventilation plan include the minimum air quantity and the position and placement of ventilation controls to be maintained during roof bolting.\n\n(e) If auxiliary fans and tubing are used, they shall be inspected frequently.\n\n(f) During each shift that coal is produced and at intervals not exceeding 4 hours, tests for methane shall be made by a certified person or by an atmospheric monitoring system (AMS) in each return split of air from each working section between the last working place, or longwall or shortwall face, ventilated by that split of air and the junction of the return air split with another air split, seal, or worked-out area. If auxiliary fans and tubing are used, the tests shall be made at a location outby the auxiliary fan discharge.\n\n(g) Certification. (1) The person conducting the on-shift examination in belt haulage entries shall certify by initials, date, and time that the examination was made. The certified person shall certify by initials, date, and the time at enough locations to show that the entire area has been examined.\n\n(2) The certified person directing the on-shift examination to assure compliance with the respirable dust control parameters specified in the approved mine ventilation plan shall:\n\n(i) Certify by initials, date, and time on a board maintained at the section load-out or similar location showing that the examination was made prior to resuming production; and\n\n(ii) Verify, by initials and date, the record of the results of the examination required under (a)(2) of this section to assure compliance with the respirable dust control parameters specified in the mine ventilation plan. The verification shall be made no later than the end of the shift for which the examination was made.\n\n(3) The mine foreman or equivalent mine official shall countersign each examination record required under (a)(2) of this section after it is verified by the certified person under (g)(2)(ii) of this section, and no later than the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(4) Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996, as amended at 68 FR 40138, July 7, 2003; 77 FR 20715, Apr. 6, 2012; 79 FR 24987, May 1, 2014]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518733","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}