{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518705","name":"Band Mill 2","status":"Abandoned and Sealed","status_date":"2014-07-18","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Letcher","nearest_town":"Eolia","operator_id":"P21182","operator_name":"Cumberland River Coal Company","controller_id":"C15863","controller_name":"Jeffery A  Hoops","district":"C07","office":"Harlan KY Field Office","employees":0,"latitude":37.023333,"longitude":-82.796667},"coverage":{"contributingSources":17,"registeredSources":20,"sourceRows":3932},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518705","name":"Band Mill 2"},"operator":{"type":"operator","id":"P21182","name":"Cumberland River Coal Company"},"controller":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"mine","id":"1518705","name":"Band Mill 2"},"validFrom":"1987-05-18","validTo":"2005-12-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518705|C00012|1987-05-18|2005-12-11"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21182","name":"Cumberland River Coal Company"},"object":{"type":"mine","id":"1518705","name":"Band Mill 2"},"validFrom":"2004-01-22","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518705|P21182|2004-01-22|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C00012","name":"Ashland Inc et al"},"object":{"type":"operator","id":"P21182","name":"Cumberland River Coal Company"},"validFrom":"2004-01-22","validTo":"2005-12-11","current":false,"derived":true,"evidenceMineId":"1518705","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518705|P21182|2004-01-22|C00012|1987-05-18|43322"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"mine","id":"1518705","name":"Band Mill 2"},"validFrom":"2005-12-12","validTo":"2017-09-13","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518705|C15561|2005-12-12|2017-09-13"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15561","name":"Arch Resources Inc"},"object":{"type":"operator","id":"P21182","name":"Cumberland River Coal Company"},"validFrom":"2005-12-12","validTo":"2017-09-13","current":false,"derived":true,"evidenceMineId":"1518705","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518705|P21182|2004-01-22|C15561|2005-12-12|96044"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"mine","id":"1518705","name":"Band Mill 2"},"validFrom":"2017-09-14","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518705|C15863|2017-09-14|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15863","name":"Jeffery A  Hoops"},"object":{"type":"operator","id":"P21182","name":"Cumberland River Coal Company"},"validFrom":"2017-09-14","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518705","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518705|P21182|2004-01-22|C15863|2017-09-14|97298"}}],"coverage":{"historyRecords":3,"edgeCount":7,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":23,"firstDate":"2005-05-20","lastDate":"2013-04-17","metrics":{"daysLost":1123,"injuries":21,"fatalities":0,"recentRows":0,"restrictedDays":5,"contractorRecords":2},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"100253","DOCUMENT_NO":"220131190016","ACCIDENT_DT":"04/17/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"200","NARRATIVE":"Employee was handling belt rollers when his shoulder started to hurt, employee had strained shoulder 3/4/13 but had not seeked medical attention. Employee was taken off of work effective 4/23/2013.","sourceDate":"2013-04-17"},{"SOURCE_ROW_NUMBER":"233787","DOCUMENT_NO":"220131070029","ACCIDENT_DT":"04/08/2013","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Fall from ladders","OCCUPATION":"Assayer, Geologist, Metallurgist, Engineer, Engineer management","NO_INJURIES":"1","DAYS_LOST":"5","NARRATIVE":"Employee was using a ladder to install an antenna on a pole when he fell twisting his right ankle resulting in a chip in his bone.","sourceDate":"2013-04-08"},{"SOURCE_ROW_NUMBER":"190678","DOCUMENT_NO":"220111320008","ACCIDENT_DT":"04/25/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"SLIP OR FALL OF PERSON","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"42","NARRATIVE":"Employee slipped twisting his knee, he continued to work until 05/02/2011 at which time he began loosing time.","sourceDate":"2011-04-25"},{"SOURCE_ROW_NUMBER":"70229","DOCUMENT_NO":"220111740006","ACCIDENT_DT":"01/24/2011","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"156","NARRATIVE":"Employee was lifting a miner cable when he strained his back. The employee continued to work until May 23, 2011 at which time he was removed from work by his physician. This accident has been under investigation and has now been determined (June 17, 2011)to be work related and reportable.","sourceDate":"2011-01-24"},{"SOURCE_ROW_NUMBER":"272456","DOCUMENT_NO":"220102920002","ACCIDENT_DT":"10/12/2010","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in the #5 entry between crosscuts 86 and 87 in the mine's intake entry. The fall  was above the roof bolt anchorage and measured approximately 100 feet in length.","sourceDate":"2010-10-12"},{"SOURCE_ROW_NUMBER":"229525","DOCUMENT_NO":"220102250036","ACCIDENT_DT":"08/04/2010","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by flying object","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","DAYS_LOST":"18","NARRATIVE":"Employee was struck in neck with a chip from pin as the track pin was being driven in with a hammer. Bleeding was stopped in less than 1 minute. He was transported to hospital for further exam. He was airlifted to U.K. for precautionary examination.","sourceDate":"2010-08-04"},{"SOURCE_ROW_NUMBER":"1535","DOCUMENT_NO":"220101660008","ACCIDENT_DT":"06/08/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was tramming the roof bolter out of the # 4 entry, when the roof bolter cable stuck, causing the cable to be jerked down. The cable hook struck the operator/employee on his left cheek, resulting in a laceration that required 5 stitches to close.","sourceDate":"2010-06-08"},{"SOURCE_ROW_NUMBER":"83240","DOCUMENT_NO":"220101410017","ACCIDENT_DT":"05/10/2010","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Belt foreman, Maintenance foreman, Maintenance supervisor","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was holding a pipe wrench attempting to loosen a pipe fitting when a fellow employee struck the handle of the wrench with a hammer. The hammer struck the employee on his small finger on his left hand resulting in a fracture.","sourceDate":"2010-05-10"},{"SOURCE_ROW_NUMBER":"216622","DOCUMENT_NO":"220093510017","ACCIDENT_DT":"12/09/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee, was removing the insulation on an electrical cable using a utility knife in preparation to make a cable splice. During the process he accidentally cut his left hand. The laceration required 10 stitches to close.","sourceDate":"2009-12-09"},{"SOURCE_ROW_NUMBER":"95953","DOCUMENT_NO":"220093200011","ACCIDENT_DT":"11/05/2009","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee was operating a rubber tired personnel vehicle when the front tire hit a hole in the road causing the steering wheel to spin around striking the back of his hand. This resulted in a small fracture to one of the bones in his hand.","sourceDate":"2009-11-05"},{"SOURCE_ROW_NUMBER":"182178","DOCUMENT_NO":"220092670028","ACCIDENT_DT":"07/13/2009","DEGREE_INJURY":"OCCUPATNAL ILLNESS NOT DEG 1-6","CLASSIFICATION":"DUST DISEASE OF LUNGS","ACCIDENT_TYPE":"Inhalation of radiations, caustics, toxic and noxious substances","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"Employee has contracted pneumoconiosis (Black Lung) and is a Part 90 Miner.","sourceDate":"2009-07-13"},{"SOURCE_ROW_NUMBER":"229526","DOCUMENT_NO":"220091590001","ACCIDENT_DT":"05/06/2009","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"FALL OF FACE/RIB/PILLAR/SIDE/HIGHWALL","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Continuous miner operator, Coal mole operator","NO_INJURIES":"1","DAYS_LOST":"137","NARRATIVE":"Employee was operating a continuous miner performing retreat mining, when a portion of the coal rib came loose and struck him on the back, knocking him down. He continued to work until 05/26/09 at which time he stopped due to the ongoing pain in his neck.","sourceDate":"2009-05-06"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-07-18","lastDate":"2014-07-18","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":827,"firstDate":"2004-03-16","lastDate":"2013-06-11","metrics":{"ss":266,"delinquent":781,"recentRows":0,"paidPenalty":347316,"proposedPenalty":362397,"currentAssessment":348316},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1979786","VIOLATION_NO":"8386418","ISSUE_DT":"06/11/2013","CFR_STANDARD_CD":"75.1714-8(a)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"1979787","VIOLATION_NO":"8397977","ISSUE_DT":"05/22/2013","CFR_STANDARD_CD":"77.502-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-05-22"},{"SOURCE_ROW_NUMBER":"1979785","VIOLATION_NO":"8386416","ISSUE_DT":"05/16/2013","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"263.00","CURRENT_ASSESSMENT_AMT":"263.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-05-16"},{"SOURCE_ROW_NUMBER":"1979777","VIOLATION_NO":"8386407","ISSUE_DT":"03/06/2013","CFR_STANDARD_CD":"75.904","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"1979776","VIOLATION_NO":"8386406","ISSUE_DT":"03/06/2013","CFR_STANDARD_CD":"75.1100-1(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"1979775","VIOLATION_NO":"8386405","ISSUE_DT":"02/27/2013","CFR_STANDARD_CD":"75.1103-5(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-02-27"},{"SOURCE_ROW_NUMBER":"1979774","VIOLATION_NO":"8386404","ISSUE_DT":"02/20/2013","CFR_STANDARD_CD":"75.1103-8(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-02-20"},{"SOURCE_ROW_NUMBER":"1979773","VIOLATION_NO":"8386403","ISSUE_DT":"02/14/2013","CFR_STANDARD_CD":"75.380(d)(7)(i)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"117.00","CURRENT_ASSESSMENT_AMT":"117.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-02-14"},{"SOURCE_ROW_NUMBER":"1979772","VIOLATION_NO":"8386402","ISSUE_DT":"02/12/2013","CFR_STANDARD_CD":"77.1605(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"1979771","VIOLATION_NO":"8386401","ISSUE_DT":"02/12/2013","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"1489522","VIOLATION_NO":"8397900","ISSUE_DT":"01/02/2013","CFR_STANDARD_CD":"75.512-2","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"100.00","CURRENT_ASSESSMENT_AMT":"100.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-02"},{"SOURCE_ROW_NUMBER":"1489521","VIOLATION_NO":"8397899","ISSUE_DT":"01/02/2013","CFR_STANDARD_CD":"77.205(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"392.00","CURRENT_ASSESSMENT_AMT":"392.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2013-01-02"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":21,"firstDate":"2006-02-10","lastDate":"2014-03-25","metrics":{"appeals":0,"decisions":21,"recentRows":0,"decisionPenalty":41999,"originalPenalty":56080},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"346674","VIOLATION_NO":"8379249","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"100.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2014-03-25"},{"SOURCE_ROW_NUMBER":"346673","VIOLATION_NO":"8379239","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"5080.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2014-03-25"},{"SOURCE_ROW_NUMBER":"99358","VIOLATION_NO":"8379238","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"3163.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2014-03-25"},{"SOURCE_ROW_NUMBER":"99257","VIOLATION_NO":"8379250","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1657.00","JUDGE_FIRST_NAME":"David","JUDGE_LAST_NAME":"Barbour","sourceDate":"2014-03-25"},{"SOURCE_ROW_NUMBER":"343272","VIOLATION_NO":"8379243","DOCKET_NO":"KENT 2013-651","DECISION_DT":"10/23/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"17800.00","DECISION_PENALTY_AMT":"13200.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-10-23"},{"SOURCE_ROW_NUMBER":"342488","VIOLATION_NO":"8379246","DOCKET_NO":"KENT 2013-651","DECISION_DT":"10/23/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"5300.00","DECISION_PENALTY_AMT":"5300.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-10-23"},{"SOURCE_ROW_NUMBER":"343280","VIOLATION_NO":"8398958","DOCKET_NO":"KENT 2013-671","DECISION_DT":"09/04/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"1224.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-09-04"},{"SOURCE_ROW_NUMBER":"342496","VIOLATION_NO":"8374987","DOCKET_NO":"KENT 2013-671","DECISION_DT":"09/04/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1657.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-09-04"},{"SOURCE_ROW_NUMBER":"340012","VIOLATION_NO":"8379251","DOCKET_NO":"KENT 2013-514","DECISION_DT":"07/03/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-07-03"},{"SOURCE_ROW_NUMBER":"95761","VIOLATION_NO":"8379242","DOCKET_NO":"KENT 2013-514","DECISION_DT":"07/03/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","JUDGE_FIRST_NAME":"Margaret","JUDGE_LAST_NAME":"Miller","sourceDate":"2013-07-03"},{"SOURCE_ROW_NUMBER":"338563","VIOLATION_NO":"8399219","DOCKET_NO":"KENT 2013-406","DECISION_DT":"06/13/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1050.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2013-06-13"},{"SOURCE_ROW_NUMBER":"335626","VIOLATION_NO":"8399249","DOCKET_NO":"KENT 2013-214","DECISION_DT":"05/06/2013","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"687.00","JUDGE_FIRST_NAME":"John","JUDGE_LAST_NAME":"Lewis","sourceDate":"2013-05-06"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":1091,"firstDate":"2002-02-15","lastDate":"2012-09-25","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":94,"validSamples":997,"maxConcentration":14.241,"concentrationTotal":711.151},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1163551","CASS_NUM":"58002130","SMP_TAKEN_DT":"9/25/2012","CONC":".021","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"927514","CASS_NUM":"58001645","SMP_TAKEN_DT":"9/25/2012","CONC":".058","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"387754","CASS_NUM":"58002125","SMP_TAKEN_DT":"9/25/2012","CONC":".162","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"BELT MAN/CONVEYOR MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"155346","CASS_NUM":"58001691","SMP_TAKEN_DT":"9/25/2012","CONC":".054","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-09-25"},{"SOURCE_ROW_NUMBER":"1147246","CASS_NUM":"57912180","SMP_TAKEN_DT":"6/21/2012","CONC":".048","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"829146","CASS_NUM":"57912181","SMP_TAKEN_DT":"6/21/2012","CONC":".142","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"492607","CASS_NUM":"57912812","SMP_TAKEN_DT":"6/21/2012","CONC":"0","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"BROKEN","OCC_CD_DESC":"ELECTRICIAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"227849","CASS_NUM":"57912775","SMP_TAKEN_DT":"6/21/2012","CONC":".112","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-06-21"},{"SOURCE_ROW_NUMBER":"1657025","CASS_NUM":"57934521","SMP_TAKEN_DT":"3/7/2012","CONC":".36","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-03-07"},{"SOURCE_ROW_NUMBER":"1191665","CASS_NUM":"57934517","SMP_TAKEN_DT":"3/7/2012","CONC":".228","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-03-07"},{"SOURCE_ROW_NUMBER":"394180","CASS_NUM":"57934534","SMP_TAKEN_DT":"3/7/2012","CONC":".188","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2012-03-07"},{"SOURCE_ROW_NUMBER":"734408","CASS_NUM":"51120835","SMP_TAKEN_DT":"12/2/2011","CONC":".32","SMP_TYPE_CD_DESC":"PART 90 MINER","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2011-12-02"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":13,"firstDate":"2004-07-15","lastDate":"2009-02-26","metrics":{"linkedIssuances":13},"periods":{},"recentRecords":[]},{"id":"msha-contested-violations","name":"Contested Violations","domains":["compliance","legal"],"products":["contest status","time to resolution","contested-rate context"],"rowCount":21,"firstDate":"2005-06-15","lastDate":"2012-12-17","metrics":{"decisions":21,"ssChanged":3,"recentRows":0,"decisionPenalty":41999,"proposedPenalty":56080},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"372354","CITATION_NO":"8379251","CITATION_ISSUE_DT":"12/17/2012","DOCKET_NO":"KENT 2013-514","DECISION_DT":"07/03/2013","CFR_STANDARD_CODE":"75.321(a)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1203.00","DECISION_PENALTY_AMT":"1203.00","sourceDate":"2012-12-17"},{"SOURCE_ROW_NUMBER":"200891","CITATION_NO":"8379250","CITATION_ISSUE_DT":"12/17/2012","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1657.00","sourceDate":"2012-12-17"},{"SOURCE_ROW_NUMBER":"368223","CITATION_NO":"8379249","CITATION_ISSUE_DT":"12/13/2012","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"N","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"100.00","sourceDate":"2012-12-13"},{"SOURCE_ROW_NUMBER":"425234","CITATION_NO":"8379246","CITATION_ISSUE_DT":"12/11/2012","DOCKET_NO":"KENT 2013-651","DECISION_DT":"10/23/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5300.00","DECISION_PENALTY_AMT":"5300.00","sourceDate":"2012-12-11"},{"SOURCE_ROW_NUMBER":"368290","CITATION_NO":"8379243","CITATION_ISSUE_DT":"12/11/2012","DOCKET_NO":"KENT 2013-651","DECISION_DT":"10/23/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"17800.00","DECISION_PENALTY_AMT":"13200.00","sourceDate":"2012-12-11"},{"SOURCE_ROW_NUMBER":"35285","CITATION_NO":"8379242","CITATION_ISSUE_DT":"12/11/2012","DOCKET_NO":"KENT 2013-514","DECISION_DT":"07/03/2013","CFR_STANDARD_CODE":"75.1909(c)(1)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"946.00","DECISION_PENALTY_AMT":"946.00","sourceDate":"2012-12-11"},{"SOURCE_ROW_NUMBER":"429430","CITATION_NO":"8379238","CITATION_ISSUE_DT":"12/03/2012","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"3163.00","sourceDate":"2012-12-03"},{"SOURCE_ROW_NUMBER":"31142","CITATION_NO":"8379239","CITATION_ISSUE_DT":"12/03/2012","DOCKET_NO":"KENT 2013-950","DECISION_DT":"03/25/2014","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"5080.00","DECISION_PENALTY_AMT":"5080.00","sourceDate":"2012-12-03"},{"SOURCE_ROW_NUMBER":"425013","CITATION_NO":"8398958","CITATION_ISSUE_DT":"09/27/2012","DOCKET_NO":"KENT 2013-671","DECISION_DT":"09/04/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1530.00","DECISION_PENALTY_AMT":"1224.00","sourceDate":"2012-09-27"},{"SOURCE_ROW_NUMBER":"197863","CITATION_NO":"8399249","CITATION_ISSUE_DT":"09/21/2012","DOCKET_NO":"KENT 2013-214","DECISION_DT":"05/06/2013","CFR_STANDARD_CODE":"77.205(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"687.00","sourceDate":"2012-09-21"},{"SOURCE_ROW_NUMBER":"86522","CITATION_NO":"8399247","CITATION_ISSUE_DT":"09/21/2012","DOCKET_NO":"KENT 2013-214","DECISION_DT":"05/06/2013","CFR_STANDARD_CODE":"77.502","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"687.00","DECISION_PENALTY_AMT":"687.00","sourceDate":"2012-09-21"},{"SOURCE_ROW_NUMBER":"367950","CITATION_NO":"8374987","CITATION_ISSUE_DT":"09/19/2012","DOCKET_NO":"KENT 2013-671","DECISION_DT":"09/04/2013","CFR_STANDARD_CODE":"75.202(a)","ORIGINAL_SIG_SUB_IND":"Y","DECISION_SIG_SUB_IND":"Y","PROPOSED_PENALTY_AMT":"1657.00","DECISION_PENALTY_AMT":"1657.00","sourceDate":"2012-09-19"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":520,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":8,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":121,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":8,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":3,"firstDate":"2004-01-22","lastDate":"2004-01-22","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":107,"firstDate":"2004-02-04","lastDate":"2014-06-18","metrics":{"inspectors":274,"recentRows":0,"onSiteHours":5395.5,"inspectionHours":8722.25,"inspectionSamples":931},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1075556","EVENT_NO":"6429080","INSPECTION_BEGIN_DT":"06/18/2014","INSPECTION_END_DT":"06/24/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"20.25","SUM_TOTAL_ON_SITE_HOURS":"10.25","sourceDate":"2014-06-18"},{"SOURCE_ROW_NUMBER":"139545","EVENT_NO":"4467776","INSPECTION_BEGIN_DT":"03/04/2014","INSPECTION_END_DT":"03/05/2014","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"10.5","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2014-03-04"},{"SOURCE_ROW_NUMBER":"1144005","EVENT_NO":"6428412","INSPECTION_BEGIN_DT":"02/24/2014","INSPECTION_END_DT":"02/24/2014","ACTIVITY_CODE":"E28","ACTIVITY":"Mine Idle Activity","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2014-02-24"},{"SOURCE_ROW_NUMBER":"31258","EVENT_NO":"4467767","INSPECTION_BEGIN_DT":"12/23/2013","INSPECTION_END_DT":"12/23/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"4.5","sourceDate":"2013-12-23"},{"SOURCE_ROW_NUMBER":"81646","EVENT_NO":"6427497","INSPECTION_BEGIN_DT":"07/09/2013","INSPECTION_END_DT":"07/12/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"15.75","SUM_TOTAL_ON_SITE_HOURS":"5.25","sourceDate":"2013-07-09"},{"SOURCE_ROW_NUMBER":"1151736","EVENT_NO":"6425998","INSPECTION_BEGIN_DT":"05/15/2013","INSPECTION_END_DT":"06/13/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"116.5","SUM_TOTAL_ON_SITE_HOURS":"70.25","sourceDate":"2013-05-15"},{"SOURCE_ROW_NUMBER":"135975","EVENT_NO":"6425990","INSPECTION_BEGIN_DT":"02/11/2013","INSPECTION_END_DT":"03/19/2013","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"107.75","SUM_TOTAL_ON_SITE_HOURS":"63.75","sourceDate":"2013-02-11"},{"SOURCE_ROW_NUMBER":"920198","EVENT_NO":"4468835","INSPECTION_BEGIN_DT":"01/15/2013","INSPECTION_END_DT":"01/16/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2013-01-15"},{"SOURCE_ROW_NUMBER":"86512","EVENT_NO":"4449706","INSPECTION_BEGIN_DT":"01/09/2013","INSPECTION_END_DT":"01/09/2013","ACTIVITY_CODE":"E20","ACTIVITY":"Roof Control Technical Investigation","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"8.5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2013-01-09"},{"SOURCE_ROW_NUMBER":"744968","EVENT_NO":"4467746","INSPECTION_BEGIN_DT":"01/02/2013","INSPECTION_END_DT":"01/10/2013","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"18.25","SUM_TOTAL_ON_SITE_HOURS":"10.25","sourceDate":"2013-01-02"},{"SOURCE_ROW_NUMBER":"1032166","EVENT_NO":"4468834","INSPECTION_BEGIN_DT":"12/27/2012","INSPECTION_END_DT":"12/27/2012","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2012-12-27"},{"SOURCE_ROW_NUMBER":"405540","EVENT_NO":"6427436","INSPECTION_BEGIN_DT":"11/26/2012","INSPECTION_END_DT":"12/31/2012","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"133.75","SUM_TOTAL_ON_SITE_HOURS":"88.75","sourceDate":"2012-11-26"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":106,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2013-Q4":{"hours":0,"employees":0,"production":0},"2013-Q2":{"hours":2360,"employees":5,"production":0},"2013-Q1":{"hours":2226,"employees":4,"production":0},"2012-Q4":{"hours":2707,"employees":5,"production":0},"2012-Q3":{"hours":3373,"employees":7,"production":0},"2012-Q2":{"hours":3101,"employees":6,"production":0},"2012-Q1":{"hours":3101,"employees":6,"production":0},"2011-Q4":{"hours":21941,"employees":52,"production":43050},"2011-Q3":{"hours":32863,"employees":52,"production":67330},"2011-Q2":{"hours":46545,"employees":57,"production":72630},"2011-Q1":{"hours":40569,"employees":67,"production":40571},"2010-Q4":{"hours":32422,"employees":52,"production":19972}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":88834,"employees":34,"production":139339},"2005":{"hours":157574,"employees":62,"production":468626},"2006":{"hours":178226,"employees":67,"production":549118},"2007":{"hours":139820,"employees":54,"production":375419},"2008":{"hours":136369,"employees":49,"production":233354},"2009":{"hours":93811,"employees":38,"production":240816},"2010":{"hours":117992,"employees":48,"production":213988},"2011":{"hours":141918,"employees":57,"production":223581},"2012":{"hours":12282,"employees":6,"production":0},"2013":{"hours":4586,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":121,"firstDate":"2005-06-21","lastDate":"2011-08-05","metrics":{"recentRows":0,"doseOver100":33,"actDoseTotal":10655,"pelDoseTotal":8692},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"83805","EVENT_NO":"4442697","SURVEY_DATE":"08/05/2011","OCCUPATION_CD_DESC":"MECHANIC","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"52","PEL_DOSE_90":"35","SURVEY_TYPE":"I","sourceDate":"2011-08-05"},{"SOURCE_ROW_NUMBER":"83804","EVENT_NO":"4442697","SURVEY_DATE":"08/05/2011","OCCUPATION_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"34","PEL_DOSE_90":"31","SURVEY_TYPE":"I","sourceDate":"2011-08-05"},{"SOURCE_ROW_NUMBER":"83802","EVENT_NO":"4442480","SURVEY_DATE":"01/31/2011","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"015","ACT_DOSE_85":"35","PEL_DOSE_90":"26","SURVEY_TYPE":"I","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"83801","EVENT_NO":"4442480","SURVEY_DATE":"01/31/2011","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"60","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"83800","EVENT_NO":"4442480","SURVEY_DATE":"01/31/2011","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"015","ACT_DOSE_85":"117","PEL_DOSE_90":"100","SURVEY_TYPE":"I","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"83799","EVENT_NO":"4442480","SURVEY_DATE":"01/31/2011","OCCUPATION_CD_DESC":"TRACTOR OPERATOR/MOTORMAN","MACHINE_CD":"38","MANUFACTURER_CD":"015","ACT_DOSE_85":"84","PEL_DOSE_90":"60","SURVEY_TYPE":"I","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"83798","EVENT_NO":"4442480","SURVEY_DATE":"01/31/2011","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"143","PEL_DOSE_90":"128","SURVEY_TYPE":"I","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"83822","EVENT_NO":"6424823","SURVEY_DATE":"11/09/2010","OCCUPATION_CD_DESC":"ASSIST MINE FOREMAN/ASSIST MINE MANAGER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"64","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2010-11-09"},{"SOURCE_ROW_NUMBER":"83820","EVENT_NO":"6424823","SURVEY_DATE":"11/08/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"84","PEL_DOSE_90":"74","SURVEY_TYPE":"I","sourceDate":"2010-11-08"},{"SOURCE_ROW_NUMBER":"83819","EVENT_NO":"6424823","SURVEY_DATE":"11/08/2010","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"57","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2010-11-08"},{"SOURCE_ROW_NUMBER":"83818","EVENT_NO":"6424823","SURVEY_DATE":"11/08/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"015","ACT_DOSE_85":"54","PEL_DOSE_90":"48","SURVEY_TYPE":"I","sourceDate":"2010-11-08"},{"SOURCE_ROW_NUMBER":"83817","EVENT_NO":"6424823","SURVEY_DATE":"11/08/2010","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"015","ACT_DOSE_85":"58","PEL_DOSE_90":"52","SURVEY_TYPE":"I","sourceDate":"2010-11-08"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":95,"firstDate":"2004-05-24","lastDate":"2011-05-05","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":34.6,"validSamples":93,"quartzPctTotal":886.7},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"134127","CASSETTE_NO":"57891331","SAMPLE_DT":"05/05/2011","QUARTZ_PCT":"01.4","OCC_CODE_DESC":"BELT MAN/CONVEYOR MAN","SAMPLE_TYPE_DESC":"PART 90 MINER","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-05-05"},{"SOURCE_ROW_NUMBER":"99","CASSETTE_NO":"51059981","SAMPLE_DT":"04/25/2011","QUARTZ_PCT":"00.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-04-25"},{"SOURCE_ROW_NUMBER":"22072","CASSETTE_NO":"51060018","SAMPLE_DT":"03/31/2011","QUARTZ_PCT":"03.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-31"},{"SOURCE_ROW_NUMBER":"71111","CASSETTE_NO":"51059984","SAMPLE_DT":"03/09/2011","QUARTZ_PCT":"05.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-09"},{"SOURCE_ROW_NUMBER":"44033","CASSETTE_NO":"51060002","SAMPLE_DT":"03/09/2011","QUARTZ_PCT":"11.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-03-09"},{"SOURCE_ROW_NUMBER":"143712","CASSETTE_NO":"57890376","SAMPLE_DT":"02/23/2011","QUARTZ_PCT":"23.1","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-23"},{"SOURCE_ROW_NUMBER":"47768","CASSETTE_NO":"51096042","SAMPLE_DT":"02/21/2011","QUARTZ_PCT":"16.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-21"},{"SOURCE_ROW_NUMBER":"38696","CASSETTE_NO":"51073304","SAMPLE_DT":"02/21/2011","QUARTZ_PCT":"16.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-02-21"},{"SOURCE_ROW_NUMBER":"157221","CASSETTE_NO":"57890551","SAMPLE_DT":"01/31/2011","QUARTZ_PCT":"10.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"128483","CASSETTE_NO":"57890549","SAMPLE_DT":"01/31/2011","QUARTZ_PCT":"13.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"65921","CASSETTE_NO":"57890559","SAMPLE_DT":"01/31/2011","QUARTZ_PCT":"11.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2011-01-31"},{"SOURCE_ROW_NUMBER":"96909","CASSETTE_NO":"57860836","SAMPLE_DT":"11/08/2010","QUARTZ_PCT":"07.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2010-11-08"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":841,"firstDate":"2004-03-16","lastDate":"2013-06-11","metrics":{"ss":266,"amountDue":348316,"contested":5,"amountPaid":347316,"recentRows":0,"section104d":2,"unterminated":5,"proposedPenalty":362397},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1048721","VIOLATION_NO":"8386418","VIOLATION_ISSUE_DT":"06/11/2013","SIG_SUB":"N","PART_SECTION":"75.1714-8(a)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"06/13/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-06-11"},{"SOURCE_ROW_NUMBER":"1048722","VIOLATION_NO":"8397977","VIOLATION_ISSUE_DT":"05/22/2013","SIG_SUB":"N","PART_SECTION":"77.502-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/22/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-05-22"},{"SOURCE_ROW_NUMBER":"1048720","VIOLATION_NO":"8386416","VIOLATION_ISSUE_DT":"05/16/2013","SIG_SUB":"N","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/28/2013","PROPOSED_PENALTY":"263","AMOUNT_DUE":"263","AMOUNT_PAID":"263","CONTESTED_IND":"N","sourceDate":"2013-05-16"},{"SOURCE_ROW_NUMBER":"1048525","VIOLATION_NO":"8386407","VIOLATION_ISSUE_DT":"03/06/2013","SIG_SUB":"Y","PART_SECTION":"75.904","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/06/2013","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"1048524","VIOLATION_NO":"8386406","VIOLATION_ISSUE_DT":"03/06/2013","SIG_SUB":"N","PART_SECTION":"75.1100-1(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/06/2013","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2013-03-06"},{"SOURCE_ROW_NUMBER":"1048523","VIOLATION_NO":"8386405","VIOLATION_ISSUE_DT":"02/27/2013","SIG_SUB":"N","PART_SECTION":"75.1103-5(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/06/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-02-27"},{"SOURCE_ROW_NUMBER":"1048522","VIOLATION_NO":"8386404","VIOLATION_ISSUE_DT":"02/20/2013","SIG_SUB":"N","PART_SECTION":"75.1103-8(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"02/26/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-02-20"},{"SOURCE_ROW_NUMBER":"1048521","VIOLATION_NO":"8386403","VIOLATION_ISSUE_DT":"02/14/2013","SIG_SUB":"N","PART_SECTION":"75.380(d)(7)(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"4","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/27/2013","PROPOSED_PENALTY":"117","AMOUNT_DUE":"117","AMOUNT_PAID":"117","CONTESTED_IND":"N","sourceDate":"2013-02-14"},{"SOURCE_ROW_NUMBER":"1048520","VIOLATION_NO":"8386402","VIOLATION_ISSUE_DT":"02/12/2013","SIG_SUB":"Y","PART_SECTION":"77.1605(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2013","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"1048519","VIOLATION_NO":"8386401","VIOLATION_ISSUE_DT":"02/12/2013","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/14/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-02-12"},{"SOURCE_ROW_NUMBER":"1048400","VIOLATION_NO":"8397900","VIOLATION_ISSUE_DT":"01/02/2013","SIG_SUB":"N","PART_SECTION":"75.512-2","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/03/2013","PROPOSED_PENALTY":"100","AMOUNT_DUE":"100","AMOUNT_PAID":"100","CONTESTED_IND":"N","sourceDate":"2013-01-02"},{"SOURCE_ROW_NUMBER":"1048399","VIOLATION_NO":"8397899","VIOLATION_ISSUE_DT":"01/02/2013","SIG_SUB":"Y","PART_SECTION":"77.205(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"01/02/2013","PROPOSED_PENALTY":"392","AMOUNT_DUE":"392","AMOUNT_PAID":"392","CONTESTED_IND":"N","sourceDate":"2013-01-02"}]}],"safety":{"href":"/api/v1/mines/1518705/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518705/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","heading":"Reporting SCSR inventory and malfunctions; retention of SCSRs.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1714-8","part":"75","subchapter":"O","subpart":"R","id":"75.1714-8","citation":"30 CFR 75.1714-8","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Electric equipment; frequency of examination and testing.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502-2","part":"77","subchapter":"O","subpart":"F","id":"77.502-2","citation":"30 CFR 77.502-2","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.904","heading":"Identification of circuit breakers.","id":"75.904","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-J/section-75.904","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"J","subpartHeading":"Subpart J—Underground Low- and Medium-Voltage Alternating Current Circuits","text":"[Statutory Provisions]\n\nCircuit breakers shall be marked for identification.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1100-1","heading":"Type and quality of firefighting equipment.","id":"75.1100-1","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1100-1","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Firefighting equipment required under this subpart shall meet the following minimum requirements:\n\n(a) Waterlines: Waterlines shall be capable of delivering 50 gallons of water a minute at a nozzle pressure of 50 pounds per square inch.\n\n(b) Portable water cars: A portable water car shall be of at least 1,000 gallons capacity (500 gallons capacity for anthracite mines) and shall have at least 300 feet of fire hose with nozzles. A portable water car shall be capable of providing a flow through the hose of 50 gallons of water per minute at a nozzle pressure of 50 pounds per square inch.\n\n(c) A portable chemical car shall carry enough chemicals to provide a fire extinguishing capacity equivalent to that of a portable water car.\n\n(d) Portable foam-generating machines or devices: A portable foam-generating machine or device shall have facilities and equipment for supplying the machine with 30 gallons of water per minute at 30 pounds per square inch for a period of 35 minutes.\n\n(e) Portable fire extinguisher: A portable fire extinguisher shall be either (1) a multipurpose dry chemical type containing a nominal weight of 5 pounds of dry powder and enough expellant to apply the powder or (2) a foam-producing type containing at least 2 1/2 gallons of foam-producing liquids and enough expellant to supply the foam. Only fire extinguishers approved by the Underwriters Laboratories, Inc., or Factory Mutual Research Corp., carrying appropriate labels as to type and purpose, shall be used. After March 30, 1971, all new portable fire extinguishers acquired for use in a coal mine shall have a 2A 10 BC or higher rating.\n\n(f)(1) Except as provided in paragraph (f)(2) of this section, the fire hose shall be lined with a material having flame resistant qualities meeting requirements for hose in Bureau of Mines' Schedule 2G. The cover shall be polyester, or other material with flame-spread qualities and mildew resistance equal or superior to polyester. The bursting pressure shall be at least 4 times the water pressure at the valve to the hose inlet with the valve closed; the maximum water pressure in the hose nozzle shall not exceed 100 p.s.i.g.\n\n(2) Fire hose installed for use in underground coal mines prior to December 30, 1970, shall be mildew-proof and have a bursting pressure at least 4 times the water pressure at the valve to the hose inlet with the valve closed, and the maximum water pressure in the hose nozzle with water flowing shall not exceed 100 p.s.i.g.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-5","heading":"Automatic fire warning devices; actions and response.","id":"75.1103-5","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-5","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) When the carbon monoxide level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following locations:\n\n(1) At working sections and other work locations where miners may be endangered from a fire in the belt entry.\n\n(2) At a manned surface location where personnel have an assigned post of duty. The manned surface location must have:\n\n(i) A telephone or equivalent communication with all miners who may be endangered and\n\n(ii) A map or schematic that shows the locations of sensors, and the intended air flow direction at these locations. This map or schematic must be updated within 24 hours of any change in this information.\n\n(3) The automatic fire sensor and warning device system shall be monitored for a period of 4 hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in § 75.1103-4(e).\n\n(b) The fire sensor and warning device system shall include a means for rapid evaluation of electrical short and open circuits, ground faults, pneumatic leaks, or other defect detrimental to its proper operational condition.\n\n(c) Automatic fire sensor and warning devices shall include a manual reset feature.\n\n(d) When a malfunction or warning signal is received at the manned surface location, the sensors that are activated must be identified and appropriate personnel immediately notified.\n\n(e) Upon notification of a malfunction or warning signal, appropriate personnel must immediately initiate an investigation to determine the cause of the malfunction or warning signal and take the required actions set forth in paragraph (f) of this section.\n\n(f) If any sensor indicates a warning, the following actions must be taken unless the mine operator determines that the signal does not present a hazard to miners:\n\n(1) Appropriate personnel must notify miners in affected working sections, in affected areas where mechanized mining equipment is being installed or removed, and at other locations specified in the approved mine emergency evacuation and firefighting program of instruction; and\n\n(2) All miners in the affected areas, unless assigned emergency response duties, must be immediately withdrawn to a safe location identified in the mine emergency evacuation and firefighting program of instruction.\n\n(g) If the warning signal will be activated during calibration of sensors, personnel manning the surface location must be notified prior to and upon completion of calibration. Affected working sections, areas where mechanized mining equipment is being installed or removed, or other areas designated in the approved emergency evacuation and firefighting program of instruction must be notified at the beginning and completion of calibration.\n\n(h) If any fire detection component becomes inoperative, immediate action must be taken to repair the component. While repairs are being made, operation of the belt may continue if the following requirements are met:\n\n(1) If one sensor becomes inoperative, a trained person must continuously monitor for carbon monoxide at the inoperative sensor;\n\n(2) If two or more adjacent sensors become inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety. Alternatively, a trained person must be stationed at each inoperative sensor to monitor for carbon monoxide;\n\n(3) If the complete fire detection system becomes inoperative, trained persons must patrol and continuously monitor the affected areas for carbon monoxide so that they will be traveled each hour in their entirety;\n\n(4) Trained persons who conduct monitoring under this section must have two-way voice communication capability, at intervals not to exceed 2,000 feet, and must report carbon monoxide concentrations to the surface at intervals not to exceed one hour;\n\n(5) Trained persons who conduct monitoring under this section must immediately report to the surface any concentration of carbon monoxide that reaches 10 parts per million above the established ambient level, unless the mine operator knows that the source of the carbon monoxide does not present a hazard to miners; and\n\n(6) Handheld detectors used to monitor the belt entry under this section must have a detection level equivalent to that of the system's carbon monoxide sensors.\n\n[37 FR 16545, Aug. 16, 1972, as amended at 73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1103-8","heading":"Automatic fire sensor and warning device systems; examination and test requirements.","id":"75.1103-8","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-8","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) Automatic fire sensor and warning device systems shall be examined at least once each shift when belts are operated as part of a production shift. A functional test of the warning signals shall be made at least once every seven days. Examination and maintenance of such systems shall be by a qualified person.\n\n(b) A record of the functional test conducted in accordance with paragraph (a) of this section shall be maintained by the operator and kept for a period of one year.\n\n(c) Sensors shall be calibrated in accordance with the manufacturer's calibration instructions at intervals not to exceed 31 days. A record of the sensor calibrations shall be maintained by the operator and kept for a period of one year.\n\n[73 FR 80615, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.380","heading":"Escapeways; bituminous and lignite mines.","id":"75.380","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.380","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Except in situations addressed in § 75.381, § 75.385 and § 75.386, at least two separate and distinct travelable passageways shall be designated as escapeways and shall meet the requirements of this section.\n\n(b) (1) Escapeways shall be provided from each working section, and each area where mechanized mining equipment is being installed or removed, continuous to the surface escape drift opening or continuous to the escape shaft or slope facilities to the surface.\n\n(2) During equipment installation, these escapeways shall begin at the projected location for the section loading point. During equipment removal, they shall begin at the location of the last loading point.\n\n(c) The two separate and distinct escapeways required by this section shall not end at a common shaft, slope, or drift opening, except that multiple compartment shafts or slopes separated by walls constructed of noncombustible material may be used as separate and distinct passageways.\n\n(d) Each escapeway shall be—\n\n(1) Maintained in a safe condition to always assure passage of anyone, including disabled persons;\n\n(2) Clearly marked to show the route and direction of travel to the surface;\n\n(3) Maintained to at least a height of 5 feet from the mine floor to the mine roof, excluding the thickness of any roof support, except that the escapeways shall be maintained to at least the height of the coalbed, excluding the thickness of any roof support, where the coalbed is less than 5 feet. In areas of mines where escapeways pass through doors, the height may be less than 5 feet, provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. In areas of mines developed before November 16, 1992, where escapeways pass over or under overcasts or undercasts, the height may be less than 5 feet provided that sufficient height is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient height is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(4) Maintained at least 6 feet wide except—\n\n(i) Where necessary supplemental roof support is installed, the escapeway shall not be less than 4 feet wide; or\n\n(ii) Where the route of travel passes through doors or other permanent ventilation controls, the escapeway shall be at least 4 feet wide to enable miners to escape quickly in an emergency, or\n\n(iii) Where the alternate escapeway passes through doors or other permanent ventilation controls or where supplemental roof support is required and sufficient width is maintained to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher, or\n\n(iv) Where mobile equipment near working sections, and other equipment essential to the ongoing operation of longwall sections, is necessary during normal mining operations, such as material cars containing rock dust or roof control supplies, or is to be used for the evacuation of miners off the section in the event of an emergency. In any instance, escapeways shall be of sufficient width to enable miners, including disabled persons, to escape quickly in an emergency. When there is a need to determine whether sufficient width is provided, MSHA may require a stretcher test where 4 persons carry a miner through the area in question on a stretcher;\n\n(5) Located to follow the most direct, safe and practical route to the nearest mine opening suitable for the safe evacuation of miners; and\n\n(6) Provided with ladders, stairways, ramps, or similar facilities where the escapeways cross over obstructions.\n\n(7) Provided with a continuous, durable directional lifeline or equivalent device that shall be—\n\n(i) Installed and maintained throughout the entire length of each escapeway as defined in paragraph (b)(1) of this section;\n\n(ii) Flame-resistant in accordance with the requirements of part 18 of this chapter upon replacement of existing lifelines; but in no case later than June 15, 2009;\n\n(iii) Marked with a reflective material every 25 feet;\n\n(iv) Located in such a manner for miners to use effectively to escape;\n\n(v) Equipped with one directional indicator cone securely attached to the lifeline, signifying the route of escape, placed at intervals not exceeding 100 feet. Cones shall be installed so that the tapered section points inby;\n\n(vi) Equipped with one sphere securely attached to the lifeline at each intersection where personnel doors are installed in adjacent crosscuts;\n\n(vii) Equipped with two securely attached cones, installed consecutively with the tapered section pointing inby, to signify an attached branch line is immediately ahead.\n\n(A) A branch line leading from the lifeline to an SCSR cache will be marked with four cones with the base sections in contact to form two diamond shapes. The cones must be placed within reach of the lifeline.\n\n(B) A branch line leading from the lifeline to a refuge alternative will be marked with a rigid spiraled coil at least eight inches in length. The spiraled coil must be placed within reach of the lifeline (see Illustration 1 below).\n\n(e) Surface openings shall be adequately protected to prevent surface fires, fumes, smoke, and flood water from entering the mine.\n\n(f) Primary escapeway. (1) One escapeway that is ventilated with intake air shall be designated as the primary escapeway. The primary escapeway shall have a higher ventilation pressure than the belt entry unless the mine operator submits an alternative in the mine ventilation plan to protect the integrity of the primary escapeway, based on mine specific conditions, which is approved by the district manager.\n\n(2) Paragraphs (f)(3) through (f)(7) of this section apply as follows:\n\n(i) To all areas of a primary escapeway developed on or after November 16, 1992;\n\n(ii) Effective as of June 10, 1997, to all areas of a primary escapeway developed between March 30, 1970 and November 16, 1992; and\n\n(iii) Effective as of June 10, 1997, to all areas of the primary escapeway developed prior to March 30, 1970 where separation of the belt and trolley haulage entries from the primary escapeway existed prior to November 16, 1992.\n\n(3) The following equipment is not permitted in the primary escapeway:\n\n(i) Mobile equipment hauling coal except for hauling coal incidental to cleanup or maintenance of the primary escapeway.\n\n(ii) Compressors, except—\n\n(A) Compressors necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Compressors that are components of equipment such as locomotives and rock dusting machines; and\n\n(C) Compressors of less than five horsepower.\n\n(iii) Underground transformer stations, battery charging stations, substations, and rectifiers except—\n\n(A) Where necessary to maintain the escapeway in safe, travelable condition; and\n\n(B) Battery charging stations and rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid, provided they are located on or near a working section and are moved as the section advances or retreats.\n\n(iv) Water pumps, except—\n\n(A) Water pumps necessary to maintain the escapeway in safe, travelable condition;\n\n(B) Submersible pumps;\n\n(C) Permissible pumps and associated permissible switchgear;\n\n(D) Pumps located on or near a working section that are moved as the section advances or retreats;\n\n(E) Pumps installed in anthracite mines; and\n\n(F) Small portable pumps.\n\n(4) Mobile equipment operated in the primary escapeway, except for continuous miners and as provided in paragraphs (f)(5), (f)(6), and (f)(7) of this section, shall be equipped with a fire suppression system installed according to §§ 75.1107-3 through 75.1107-16 that is—\n\n(i) Manually operated and attended continuously by a person trained in the systems function and use, or\n\n(ii) A multipurpose dry chemical type capable of both automatic and manual activation.\n\n(5) Personnel carriers and small mobile equipment designed and used only for carrying people and small hand tools may be operated in primary escapeways if—\n\n(i) The equipment is provided with a multipurpose dry chemical type fire suppression system capable of both automatic and manual activation, and the suppression system is suitable for the intended application and is listed or approved by a nationally recognized independent testing laboratory, or,\n\n(ii) Battery powered and provided with two 10 pound multipurpose dry chemical portable fire extinguishers.\n\n(6) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment not provided with a fire suppression system may operate in the primary escapeway if no one is inby except those persons directly engaged in using or moving the equipment.\n\n(7) Notwithstanding the requirements of paragraph (f)(3)(i), mobile equipment designated and used only as emergency vehicles or ambulances, may be operated in the primary escapeway without fire suppression systems.\n\n(g) Except where separation of belt and trolley haulage entries from designated escapeways did not exist before November 15, 1992, and except as provided in § 75.350(c), the primary escapeway must be separated from belt and trolley haulage entries for its entire length, to and including the first connecting crosscut outby each loading point except when a greater or lesser distance for this separation is specified and approved in the mine ventilation plan and does not pose a hazard to miners.\n\n(h) Alternate escapeway. One escapeway shall be designated as the alternate escapeway. The alternate escapeway shall be separated from the primary escapeway for its entire length, except that the alternate and primary escapeways may be ventilated from a common intake air shaft or slope opening.\n\n(i) Mechanical escape facilities shall be provided and maintained for—\n\n(1) Each shaft that is part of a designated escapeway and is greater than 50 feet in depth; and\n\n(2) Each slope from the coal seam to the surface that is part of a designated escapeway and is inclined more than 9 degrees from the horizontal.\n\n(j) Within 30 minutes after mine personnel on the surface have been notified of an emergency requiring evacuation, mechanical escape facilities provided under paragraph (i) of this section shall be operational at the bottom of shaft and slope openings that are part of escapeways.\n\n(k) Except where automatically activated hoisting equipment is used, the bottom of each shaft or slope opening that is part of a designated escapeway shall be equipped with a means of signaling a surface location where a person is always on duty when anyone is underground. When the signal is activated or the evacuation of persons underground is necessary, the person shall assure that mechanical escape facilities are operational as required by paragraph (j) of this section.\n\n(l)(1) Stairways or mechanical escape facilities shall be installed in shafts that are part of the designated escapeways and that are 50 feet or less in depth, except ladders may be used in shafts that are part of the designated escapeways and that are 5 feet or less in depth.\n\n(2) Stairways shall be constructed of concrete or metal, set on an angle not to exceed 45 degrees from the horizontal, and equipped on the open side with handrails. In addition, landing platforms that are at least 2 feet by 4 feet shall be installed at intervals not to exceed 20 vertical feet on the stairways and equipped on the open side with handrails.\n\n(3) Ladders shall be constructed of metal, anchored securely, and set on an angle not to exceed 60 degrees from the horizontal.\n\n(m) A travelway designed to prevent slippage shall be provided in slope and drift openings that are part of designated escapeways, unless mechanical escape facilities are installed.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996, as amended at 61 FR 55527, Oct. 25, 1996; 69 FR 17530, Apr. 2, 2004; 71 FR 12269, Mar. 9, 2006; 71 FR 71452, Dec. 8, 2006; 73 FR 80613, Dec. 31, 2008]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.512-2","heading":"Frequency of examinations.","id":"75.512-2","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.512-2","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"The examinations and tests required by § 75.512 shall be made at least weekly. Permissible equipment shall be examined to see that it is in permissible condition.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.205","heading":"Travelways at surface installations.","id":"77.205","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.205","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Safe means of access shall be provided and maintained to all working places.\n\n(b) Travelways and platforms or other means of access to areas where persons are required to travel or work, shall be kept clear of all extraneous material and other stumbling or slipping hazards.\n\n(c) Inclined travelways shall be constructed of nonskid material or equipped with cleats.\n\n(d) Regularly used travelways shall be sanded, salted, or cleared of snow and ice as soon as practicable.\n\n(e) Crossovers, elevated walkways, elevated ramps, and stairways shall be of substantial construction, provided with handrails, and maintained in good condition. Where necessary toeboards shall be provided.\n\n(f) Crossovers shall be provided where it is necessary to cross conveyors.\n\n(g) Moving conveyors shall be crossed only at designated crossover points.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518705","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}