{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518656","name":"Pride Mining Inc  #3","status":"Abandoned and Sealed","status_date":"2012-05-11","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Floyd","nearest_town":"Price","operator_id":"0050920","operator_name":"Pride Mining, Inc","controller_id":"C15865","controller_name":"Donna L  Johnson","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":37.406388,"longitude":-82.743888},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":720},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"operator":{"type":"operator","id":"0050920","name":"Pride Mining, Inc"},"controller":{"type":"controller","id":"C15865","name":"Donna L  Johnson"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C03666","name":"Ronald G  Goff"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2000-05-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|C03666|2000-05-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15865","name":"Donna L  Johnson"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2003-01-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|C15865|2003-01-01|"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14417","name":"Steve  Meade"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2003-03-15","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|C14417|2003-03-15|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051425","name":"RPM Mining Inc"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2003-08-12","validTo":"2003-08-21","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0051425|2003-08-12|2003-08-21"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C14586","name":"Pat R  Childers"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2003-08-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|C14586|2003-08-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14586","name":"Pat R  Childers"},"object":{"type":"operator","id":"0051425","name":"RPM Mining Inc"},"validFrom":"2003-08-12","validTo":"2003-08-21","current":false,"derived":true,"evidenceMineId":"1518656","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0051425|2003-08-12|C14586|2003-08-12|93344"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0051275","name":"Mountaintop, Inc."},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2003-08-22","validTo":"2004-02-23","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0051275|2003-08-22|2004-02-23"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C14417","name":"Steve  Meade"},"object":{"type":"operator","id":"0051275","name":"Mountaintop, Inc."},"validFrom":"2003-08-22","validTo":"2004-02-23","current":false,"derived":true,"evidenceMineId":"1518656","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0051275|2003-08-22|C14417|2003-03-15|92748"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24399","name":"RAMA Development Co., Inc."},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2004-02-24","validTo":"2004-08-23","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|P24399|2004-02-24|2004-08-23"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C03666","name":"Ronald G  Goff"},"object":{"type":"operator","id":"P24399","name":"RAMA Development Co., Inc."},"validFrom":"2004-02-24","validTo":"2004-08-23","current":false,"derived":true,"evidenceMineId":"1518656","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|P24399|2004-02-24|C03666|2000-05-01|63504"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0053877","name":"B. King Coal Company, Inc."},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2004-08-24","validTo":"2006-05-16","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0053877|2004-08-24|2006-05-16"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0044631","name":"Alger B  Jent"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2004-08-24","validTo":"2006-04-18","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0044631|2004-08-24|2006-04-18"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0044631","name":"Alger B  Jent"},"object":{"type":"operator","id":"0053877","name":"B. King Coal Company, Inc."},"validFrom":"2004-08-24","validTo":"2006-04-18","current":false,"derived":true,"evidenceMineId":"1518656","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0053877|2004-08-24|0044631|2004-08-24|5113"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0059009","name":"Barry W  King"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2006-04-19","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0059009|2006-04-19|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0059009","name":"Barry W  King"},"object":{"type":"operator","id":"0053877","name":"B. King Coal Company, Inc."},"validFrom":"2006-04-19","validTo":"2006-05-16","current":false,"derived":true,"evidenceMineId":"1518656","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0053877|2004-08-24|0059009|2006-04-19|7835"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"0050920","name":"Pride Mining, Inc"},"object":{"type":"mine","id":"1518656","name":"Pride Mining Inc  #3"},"validFrom":"2006-05-17","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0050920|2006-05-17|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15865","name":"Donna L  Johnson"},"object":{"type":"operator","id":"0050920","name":"Pride Mining, Inc"},"validFrom":"2006-05-17","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518656","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518656|0050920|2006-05-17|C15865|2003-01-01|97343"}}],"coverage":{"historyRecords":6,"edgeCount":17,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":1,"firstDate":"2004-08-29","lastDate":"2004-08-29","metrics":{"daysLost":1,"injuries":1,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"139114","DOCUMENT_NO":"220042510037","ACCIDENT_DT":"08/29/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"POWERED HAULAGE","ACCIDENT_TYPE":"Struck against a moving object","OCCUPATION":"Shuttle car operator, Mantrip operator, Ramcar operator, Rail runner, Buggy operator","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"EMPLOYEE WAS OPERATING A SHUTTLE CAR & CLAIMS THAT HE RAN OVER SOMETHING IN ROADWAY & JAMMED HIS HEAD INTO SHUTTLE CAR CANOPY. IT WAS OBSERVED THAT NOTHING WAS IN THE ROADWAY. INJURED WAS TREATED & TRANSPORTED BY AMBULANCE TO HOSPITAL.","sourceDate":"2004-08-29"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2012-05-11","lastDate":"2012-05-11","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":207,"firstDate":"2003-09-18","lastDate":"2006-06-26","metrics":{"ss":105,"delinquent":207,"recentRows":0,"paidPenalty":1919,"proposedPenalty":30506,"currentAssessment":30506},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1015749","VIOLATION_NO":"7434100","ISSUE_DT":"06/26/2006","CFR_STANDARD_CD":"75.333(h)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"1015748","VIOLATION_NO":"7434099","ISSUE_DT":"06/26/2006","CFR_STANDARD_CD":"75.1722(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"99.00","CURRENT_ASSESSMENT_AMT":"99.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"1015747","VIOLATION_NO":"7434098","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.363(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015746","VIOLATION_NO":"7434097","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.1722(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015745","VIOLATION_NO":"7434096","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015744","VIOLATION_NO":"7434095","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015743","VIOLATION_NO":"7434094","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015742","VIOLATION_NO":"7434093","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.202(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"203.00","CURRENT_ASSESSMENT_AMT":"203.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015741","VIOLATION_NO":"7434092","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015740","VIOLATION_NO":"7434091","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.1103-1","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015739","VIOLATION_NO":"7434090","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"75.400","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1015738","VIOLATION_NO":"7434089","ISSUE_DT":"06/16/2006","CFR_STANDARD_CD":"77.410(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"99.00","CURRENT_ASSESSMENT_AMT":"99.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-06-16"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":127,"firstDate":"2004-08-16","lastDate":"2006-06-30","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":19,"validSamples":108,"maxConcentration":4.046,"concentrationTotal":72.32},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"987293","CASS_NUM":"50856800","SMP_TAKEN_DT":"6/30/2006","CONC":".373","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"DISCARDED SAMPLE (TOO OLD)","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-30"},{"SOURCE_ROW_NUMBER":"41270","CASS_NUM":"50812189","SMP_TAKEN_DT":"6/29/2006","CONC":".444","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-29"},{"SOURCE_ROW_NUMBER":"1297446","CASS_NUM":"50812169","SMP_TAKEN_DT":"6/28/2006","CONC":".82","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-28"},{"SOURCE_ROW_NUMBER":"1660244","CASS_NUM":"57625474","SMP_TAKEN_DT":"6/27/2006","CONC":".25","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"1656917","CASS_NUM":"57625491","SMP_TAKEN_DT":"6/27/2006","CONC":".276","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"1476462","CASS_NUM":"57625475","SMP_TAKEN_DT":"6/27/2006","CONC":".182","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"1392181","CASS_NUM":"57625514","SMP_TAKEN_DT":"6/27/2006","CONC":".383","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"431653","CASS_NUM":"57625522","SMP_TAKEN_DT":"6/27/2006","CONC":"1.063","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"114984","CASS_NUM":"50812220","SMP_TAKEN_DT":"6/27/2006","CONC":".333","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"INVALID OR MISSING TIME","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"864707","CASS_NUM":"50812187","SMP_TAKEN_DT":"6/26/2006","CONC":".638","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"426509","CASS_NUM":"50856804","SMP_TAKEN_DT":"6/20/2006","CONC":"1.529","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-06-20"},{"SOURCE_ROW_NUMBER":"1579217","CASS_NUM":"57627130","SMP_TAKEN_DT":"3/28/2006","CONC":".303","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2006-03-28"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":3,"firstDate":"2004-10-29","lastDate":"2004-10-29","metrics":{"linkedIssuances":3},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":60,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":2,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":6,"firstDate":"2003-08-12","lastDate":"2006-05-17","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":5},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":34,"firstDate":"2003-08-13","lastDate":"2006-09-05","metrics":{"inspectors":57,"recentRows":0,"onSiteHours":688.5,"inspectionHours":1051,"inspectionSamples":10},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"633410","EVENT_NO":"4190163","INSPECTION_BEGIN_DT":"09/05/2006","INSPECTION_END_DT":"09/28/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2006-09-05"},{"SOURCE_ROW_NUMBER":"1058557","EVENT_NO":"4189100","INSPECTION_BEGIN_DT":"04/17/2006","INSPECTION_END_DT":"06/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"72","SUM_TOTAL_ON_SITE_HOURS":"49.5","sourceDate":"2006-04-17"},{"SOURCE_ROW_NUMBER":"646263","EVENT_NO":"4189554","INSPECTION_BEGIN_DT":"01/11/2006","INSPECTION_END_DT":"03/31/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"74.5","SUM_TOTAL_ON_SITE_HOURS":"55.5","sourceDate":"2006-01-11"},{"SOURCE_ROW_NUMBER":"823442","EVENT_NO":"4189551","INSPECTION_BEGIN_DT":"10/25/2005","INSPECTION_END_DT":"12/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"55","SUM_TOTAL_ON_SITE_HOURS":"40.5","sourceDate":"2005-10-25"},{"SOURCE_ROW_NUMBER":"966847","EVENT_NO":"4188836","INSPECTION_BEGIN_DT":"10/06/2005","INSPECTION_END_DT":"10/14/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2005-10-06"},{"SOURCE_ROW_NUMBER":"477944","EVENT_NO":"4189075","INSPECTION_BEGIN_DT":"07/05/2005","INSPECTION_END_DT":"09/26/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"115.5","SUM_TOTAL_ON_SITE_HOURS":"85","sourceDate":"2005-07-05"},{"SOURCE_ROW_NUMBER":"3478","EVENT_NO":"4188825","INSPECTION_BEGIN_DT":"06/29/2005","INSPECTION_END_DT":"09/06/2005","ACTIVITY_CODE":"E08","ACTIVITY":"Non-Injury Accident Investigation","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"10","SUM_TOTAL_ON_SITE_HOURS":"6","sourceDate":"2005-06-29"},{"SOURCE_ROW_NUMBER":"3668","EVENT_NO":"4189065","INSPECTION_BEGIN_DT":"04/18/2005","INSPECTION_END_DT":"06/13/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"103","SUM_TOTAL_ON_SITE_HOURS":"71","sourceDate":"2005-04-18"},{"SOURCE_ROW_NUMBER":"1132452","EVENT_NO":"4189064","INSPECTION_BEGIN_DT":"04/07/2005","INSPECTION_END_DT":"04/20/2005","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2005-04-07"},{"SOURCE_ROW_NUMBER":"599399","EVENT_NO":"4189061","INSPECTION_BEGIN_DT":"03/16/2005","INSPECTION_END_DT":"03/29/2005","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"8.5","sourceDate":"2005-03-16"},{"SOURCE_ROW_NUMBER":"467189","EVENT_NO":"4184349","INSPECTION_BEGIN_DT":"01/03/2005","INSPECTION_END_DT":"01/11/2005","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2005-01-03"},{"SOURCE_ROW_NUMBER":"462570","EVENT_NO":"4184348","INSPECTION_BEGIN_DT":"01/03/2005","INSPECTION_END_DT":"03/29/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"4","SUM_TOTAL_INSP_HOURS":"128.5","SUM_TOTAL_ON_SITE_HOURS":"89","sourceDate":"2005-01-03"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":20,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2006-Q2":{"hours":1635,"employees":12,"production":16748},"2006-Q1":{"hours":8297,"employees":17,"production":24607},"2005-Q4":{"hours":7281,"employees":15,"production":11382},"2005-Q3":{"hours":2324,"employees":16,"production":20854},"2005-Q2":{"hours":5280,"employees":11,"production":16365},"2005-Q1":{"hours":0,"employees":0,"production":0},"2004-Q4":{"hours":5760,"employees":12,"production":17261},"2004-Q3":{"hours":6240,"employees":12,"production":9486},"2004-Q2":{"hours":1116,"employees":14,"production":4393},"2004-Q1":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":5,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004":{"hours":13116,"employees":14,"production":31140},"2005":{"hours":14885,"employees":15,"production":48601},"2006":{"hours":9932,"employees":15,"production":41355}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":15,"firstDate":"2004-08-16","lastDate":"2005-11-29","metrics":{"recentRows":0,"doseOver100":2,"actDoseTotal":802,"pelDoseTotal":603},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"83114","EVENT_NO":"4189551","SURVEY_DATE":"11/29/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER HELPER","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"23","PEL_DOSE_90":"15","SURVEY_TYPE":"I","sourceDate":"2005-11-29"},{"SOURCE_ROW_NUMBER":"83113","EVENT_NO":"4189551","SURVEY_DATE":"11/29/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"53","PEL_DOSE_90":"37","SURVEY_TYPE":"I","sourceDate":"2005-11-29"},{"SOURCE_ROW_NUMBER":"83112","EVENT_NO":"4189551","SURVEY_DATE":"11/29/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"17","PEL_DOSE_90":"9","SURVEY_TYPE":"I","sourceDate":"2005-11-29"},{"SOURCE_ROW_NUMBER":"83111","EVENT_NO":"4189551","SURVEY_DATE":"11/29/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"50","PEL_DOSE_90":"41","SURVEY_TYPE":"I","sourceDate":"2005-11-29"},{"SOURCE_ROW_NUMBER":"83104","EVENT_NO":"4184349","SURVEY_DATE":"01/10/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"28","PEL_DOSE_90":"14","SURVEY_TYPE":"I","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"83103","EVENT_NO":"4184349","SURVEY_DATE":"01/10/2005","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"39","PEL_DOSE_90":"28","SURVEY_TYPE":"I","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"83102","EVENT_NO":"4184349","SURVEY_DATE":"01/10/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"15","PEL_DOSE_90":"6","SURVEY_TYPE":"I","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"83101","EVENT_NO":"4184349","SURVEY_DATE":"01/10/2005","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"22","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"83100","EVENT_NO":"4184349","SURVEY_DATE":"01/10/2005","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"50","PEL_DOSE_90":"39","SURVEY_TYPE":"I","sourceDate":"2005-01-10"},{"SOURCE_ROW_NUMBER":"83110","EVENT_NO":"4184383","SURVEY_DATE":"08/16/2004","OCCUPATION_CD_DESC":"SECTION FOREMAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"60","PEL_DOSE_90":"43","SURVEY_TYPE":"I","sourceDate":"2004-08-16"},{"SOURCE_ROW_NUMBER":"83109","EVENT_NO":"4184383","SURVEY_DATE":"08/16/2004","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"066","ACT_DOSE_85":"150","PEL_DOSE_90":"131","SURVEY_TYPE":"I","sourceDate":"2004-08-16"},{"SOURCE_ROW_NUMBER":"83108","EVENT_NO":"4184383","SURVEY_DATE":"08/16/2004","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"098","ACT_DOSE_85":"43","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2004-08-16"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":15,"firstDate":"2004-08-16","lastDate":"2006-06-27","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":14.1,"validSamples":13,"quartzPctTotal":114.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"21199","CASSETTE_NO":"57625522","SAMPLE_DT":"06/27/2006","QUARTZ_PCT":"07.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-06-27"},{"SOURCE_ROW_NUMBER":"48862","CASSETTE_NO":"57627059","SAMPLE_DT":"03/28/2006","QUARTZ_PCT":"11.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-03-28"},{"SOURCE_ROW_NUMBER":"163751","CASSETTE_NO":"50834379","SAMPLE_DT":"01/17/2006","QUARTZ_PCT":"03.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-01-17"},{"SOURCE_ROW_NUMBER":"23519","CASSETTE_NO":"50768065","SAMPLE_DT":"12/21/2005","QUARTZ_PCT":"04.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-12-21"},{"SOURCE_ROW_NUMBER":"24791","CASSETTE_NO":"57612411","SAMPLE_DT":"11/29/2005","QUARTZ_PCT":"13.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-11-29"},{"SOURCE_ROW_NUMBER":"57180","CASSETTE_NO":"50812252","SAMPLE_DT":"09/09/2005","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"INSUFFICIENT WEIGHT GAIN","sourceDate":"2005-09-09"},{"SOURCE_ROW_NUMBER":"111730","CASSETTE_NO":"57575639","SAMPLE_DT":"08/24/2005","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-24"},{"SOURCE_ROW_NUMBER":"43702","CASSETTE_NO":"50796276","SAMPLE_DT":"08/12/2005","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"UNACCEPTABLE TIMEFRAME","sourceDate":"2005-08-12"},{"SOURCE_ROW_NUMBER":"18387","CASSETTE_NO":"57575514","SAMPLE_DT":"07/14/2005","QUARTZ_PCT":"14.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-07-14"},{"SOURCE_ROW_NUMBER":"167728","CASSETTE_NO":"50789269","SAMPLE_DT":"05/10/2005","QUARTZ_PCT":"08.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-05-10"},{"SOURCE_ROW_NUMBER":"101214","CASSETTE_NO":"50789217","SAMPLE_DT":"04/18/2005","QUARTZ_PCT":"08.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-18"},{"SOURCE_ROW_NUMBER":"33910","CASSETTE_NO":"57576651","SAMPLE_DT":"03/28/2005","QUARTZ_PCT":"11.1","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-03-28"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":211,"firstDate":"2003-09-18","lastDate":"2006-06-26","metrics":{"ss":105,"amountDue":30506,"contested":0,"amountPaid":1919,"recentRows":0,"section104d":4,"unterminated":3,"proposedPenalty":30506},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1043311","VIOLATION_NO":"7434100","VIOLATION_ISSUE_DT":"06/26/2006","SIG_SUB":"N","PART_SECTION":"75.333(h)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/27/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"1043310","VIOLATION_NO":"7434099","VIOLATION_ISSUE_DT":"06/26/2006","SIG_SUB":"Y","PART_SECTION":"75.1722(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/27/2006","PROPOSED_PENALTY":"99","AMOUNT_DUE":"99","AMOUNT_PAID":"99","CONTESTED_IND":"N","sourceDate":"2006-06-26"},{"SOURCE_ROW_NUMBER":"1043309","VIOLATION_NO":"7434098","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"N","PART_SECTION":"75.363(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"HighNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043308","VIOLATION_NO":"7434097","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.1722(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"72","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043307","VIOLATION_NO":"7434096","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043306","VIOLATION_NO":"7434095","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/16/2006","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"72","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043305","VIOLATION_NO":"7434094","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043304","VIOLATION_NO":"7434093","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.202(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/29/2006","PROPOSED_PENALTY":"203","AMOUNT_DUE":"203","AMOUNT_PAID":"203","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043303","VIOLATION_NO":"7434092","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/16/2006","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"72","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043302","VIOLATION_NO":"7434091","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.1103-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/26/2006","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043301","VIOLATION_NO":"7434090","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"75.400","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/16/2006","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"72","CONTESTED_IND":"N","sourceDate":"2006-06-16"},{"SOURCE_ROW_NUMBER":"1043300","VIOLATION_NO":"7434089","VIOLATION_ISSUE_DT":"06/16/2006","SIG_SUB":"Y","PART_SECTION":"77.410(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Permanent","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/16/2006","PROPOSED_PENALTY":"99","AMOUNT_DUE":"99","AMOUNT_PAID":"99","CONTESTED_IND":"N","sourceDate":"2006-06-16"}]}],"safety":{"href":"/api/v1/mines/1518656/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518656/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.363","heading":"Hazardous conditions and violations of mandatory health or safety standards; posting, correcting, and recording.","id":"75.363","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.363","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Any hazardous condition found by the mine foreman or equivalent mine official, assistant mine foreman or equivalent mine official, or other certified persons designated by the operator for the purposes of conducting examinations under this subpart D, shall be posted with a conspicuous danger sign where anyone entering the areas would pass. A hazardous condition shall be corrected immediately or the area shall remain posted until the hazardous condition is corrected. If the condition creates an imminent danger, everyone except those persons referred to in section 104(c) of the Act shall be withdrawn from the area affected to a safe area until the hazardous condition is corrected. Only persons designated by the operator to correct or evaluate the hazardous condition may enter the posted area. Any violation of a mandatory health or safety standard found during a preshift, supplemental, on-shift, or weekly examination shall be corrected.\n\n(b) A record shall be made of any hazardous condition and any violation of the nine mandatory health or safety standards found by the mine examiner. This record shall be kept in a book maintained for this purpose on the surface at the mine. The record shall be made by the completion of the shift on which the hazardous condition or violation of the nine mandatory health or safety standards is found and shall include the nature and location of the hazardous condition or violation and the corrective action taken. This record shall not be required for shifts when no hazardous conditions or violations of the nine mandatory health or safety standards are found.\n\n(c) The record shall be made by the certified person who conducted the examination or a person designated by the operator. If made by a person other than the certified person, the certified person shall verify the record by initials and date by or at the end of the shift for which the examination was made. Records shall be countersigned by the mine foreman or equivalent mine official by the end of the mine foreman's or equivalent mine official's next regularly scheduled working shift. The record shall be made in a secure book that is not susceptible to alteration or electronically in a computer system so as to be secure and not susceptible to alteration.\n\n(d) Retention period. Records shall be retained at a surface location at the mine for at least 1 year and shall be made available for inspection by authorized representatives of the Secretary and the representative of miners.\n\n(e) Review of citations and orders. The mine operator shall review with mine examiners on a quarterly basis citations and orders issued in areas where preshift, supplemental, on-shift, and weekly examinations are required.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 26442, May 28, 1996; 77 FR 20715, Apr. 6, 2012]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.400","heading":"Accumulation of combustible materials.","id":"75.400","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-E/section-75.400","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Combustible Materials and Rock Dusting","text":"Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered and electric equipment therein.\n\n[61 FR 55527, Oct. 25, 1996]","occurrenceCount":5},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.202","heading":"Protection from falls of roof, face and ribs.","id":"75.202","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-C/section-75.202","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Roof Support","text":"(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.\n\n(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.","occurrenceCount":1},{"chapter":"I","heading":"Automatic fire sensors.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1103-1","part":"75","subchapter":"O","subpart":"L","id":"75.1103-1","citation":"30 CFR 75.1103-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518656","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}