{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518455","name":"#7 Seam","status":"Abandoned and Sealed","status_date":"2004-09-21","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Leslie","nearest_town":"Big Laurel","operator_id":"P23317","operator_name":"Bledsoe Coal Corp","controller_id":"C13562","controller_name":"James River Coal Company","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.988333,"longitude":-83.275},"coverage":{"contributingSources":15,"registeredSources":20,"sourceRows":184},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518455","name":"#7 Seam"},"operator":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corp"},"controller":{"type":"controller","id":"C13562","name":"James River Coal Company"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1518455","name":"#7 Seam"},"validFrom":"1995-06-20","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518455|C13562|1995-06-20|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corp"},"object":{"type":"mine","id":"1518455","name":"#7 Seam"},"validFrom":"2001-10-09","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518455|P23317|2001-10-09|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P23317","name":"Bledsoe Coal Corp"},"validFrom":"2001-10-09","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518455","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518455|P23317|2001-10-09|C13562|1995-06-20|90391"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":4,"firstDate":"2002-04-25","lastDate":"2002-08-14","metrics":{"daysLost":78,"injuries":2,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"220854","DOCUMENT_NO":"220022310020","ACCIDENT_DT":"08/14/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNINTENTIONAL FALL OF ROOF OCCURRED IN THE 32ND CROSSCUT OF RIDGE TOP SUBMAINS. THE FALL WAS APP 20' BY 90' BY 10' AND EXTENDED FROM SPAD #155 IN #4 ENTRY THROUGH THE CROSSCUT TO SPAD #157 IN THE #6 ENTRY.","sourceDate":"2002-08-14"},{"SOURCE_ROW_NUMBER":"229488","DOCUMENT_NO":"220022060054","ACCIDENT_DT":"07/17/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"MACHINERY","ACCIDENT_TYPE":"Struck by rolling or sliding object","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"65","NARRATIVE":"EMPLOYEE WAS STRUCK ON RIGHT HIP AND LEG BY RIB ROLL.","sourceDate":"2002-07-17"},{"SOURCE_ROW_NUMBER":"130258","DOCUMENT_NO":"220022210009","ACCIDENT_DT":"07/08/2002","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"13","NARRATIVE":"EMPLOYEE ALLEGES HE TWISTED HIS KNEE WHEN HE TURNED AROUND WHILE WORKING ON A SHUTTLE CAR. (NOTE: EMPLOYEE WORKED UNTIL 7-30-02 THEN STARTED MISSING WORK).","sourceDate":"2002-07-08"},{"SOURCE_ROW_NUMBER":"139082","DOCUMENT_NO":"220021540152","ACCIDENT_DT":"04/25/2002","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","NARRATIVE":"AN UNINTENTIONAL FALL OF ROOF OCCURRED AT THE MOUTH OF THE FIRST LEFT PANEL OFF FIRST RIGHT SUBMAINS.","sourceDate":"2002-04-25"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2004-09-21","lastDate":"2004-09-21","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":48,"firstDate":"2001-11-14","lastDate":"2002-11-05","metrics":{"ss":18,"delinquent":48,"recentRows":0,"paidPenalty":3767,"proposedPenalty":4067,"currentAssessment":3898},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1099840","VIOLATION_NO":"7541208","ISSUE_DT":"11/05/2002","CFR_STANDARD_CD":"77.1713(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-11-05"},{"SOURCE_ROW_NUMBER":"1099838","VIOLATION_NO":"7510288","ISSUE_DT":"11/05/2002","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-11-05"},{"SOURCE_ROW_NUMBER":"1099839","VIOLATION_NO":"7541207","ISSUE_DT":"11/04/2002","CFR_STANDARD_CD":"77.208(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"113.00","CURRENT_ASSESSMENT_AMT":"113.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-11-04"},{"SOURCE_ROW_NUMBER":"1138431","VIOLATION_NO":"7510833","ISSUE_DT":"09/17/2002","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1138430","VIOLATION_NO":"7510832","ISSUE_DT":"09/17/2002","CFR_STANDARD_CD":"77.1605(b)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1138429","VIOLATION_NO":"7510831","ISSUE_DT":"09/17/2002","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1138428","VIOLATION_NO":"7510830","ISSUE_DT":"09/17/2002","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"76.00","CURRENT_ASSESSMENT_AMT":"76.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1138427","VIOLATION_NO":"7510829","ISSUE_DT":"09/17/2002","CFR_STANDARD_CD":"77.1104","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1138426","VIOLATION_NO":"7510828","ISSUE_DT":"09/17/2002","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1138425","VIOLATION_NO":"7510823","ISSUE_DT":"09/11/2002","CFR_STANDARD_CD":"77.1109(c)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-11"},{"SOURCE_ROW_NUMBER":"1138424","VIOLATION_NO":"7510822","ISSUE_DT":"09/11/2002","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"104.00","CURRENT_ASSESSMENT_AMT":"104.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-11"},{"SOURCE_ROW_NUMBER":"1138423","VIOLATION_NO":"7510821","ISSUE_DT":"09/11/2002","CFR_STANDARD_CD":"77.410","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"55.00","CURRENT_ASSESSMENT_AMT":"55.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2002-09-11"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":1,"firstDate":"2003-03-24","lastDate":"2003-03-24","metrics":{"appeals":0,"decisions":1,"recentRows":0,"decisionPenalty":55,"originalPenalty":224},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"174819","VIOLATION_NO":"7498397","DOCKET_NO":"KENT20030135","DECISION_DT":"03/24/2003","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"224.00","DECISION_PENALTY_AMT":"55.00","JUDGE_FIRST_NAME":"Irwin","JUDGE_LAST_NAME":"Schroeder","sourceDate":"2003-03-24"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":35,"firstDate":"2002-03-12","lastDate":"2002-08-30","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":35,"maxConcentration":3.126,"concentrationTotal":35.39},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1037100","CASS_NUM":"50639814","SMP_TAKEN_DT":"8/30/2002","CONC":".018","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-30"},{"SOURCE_ROW_NUMBER":"1528715","CASS_NUM":"57434700","SMP_TAKEN_DT":"8/29/2002","CONC":"1.039","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"1342747","CASS_NUM":"57434709","SMP_TAKEN_DT":"8/29/2002","CONC":".257","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"1305277","CASS_NUM":"57434711","SMP_TAKEN_DT":"8/29/2002","CONC":".054","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"1135021","CASS_NUM":"57434714","SMP_TAKEN_DT":"8/29/2002","CONC":"1.379","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"1130923","CASS_NUM":"57434370","SMP_TAKEN_DT":"8/29/2002","CONC":".075","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"1104067","CASS_NUM":"57434646","SMP_TAKEN_DT":"8/29/2002","CONC":".611","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"722864","CASS_NUM":"57434455","SMP_TAKEN_DT":"8/29/2002","CONC":".183","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"282199","CASS_NUM":"57434710","SMP_TAKEN_DT":"8/29/2002","CONC":".19","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"1628713","CASS_NUM":"50637819","SMP_TAKEN_DT":"7/23/2002","CONC":"2.653","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-23"},{"SOURCE_ROW_NUMBER":"84895","CASS_NUM":"50639796","SMP_TAKEN_DT":"7/19/2002","CONC":"1.056","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-19"},{"SOURCE_ROW_NUMBER":"1457829","CASS_NUM":"50639810","SMP_TAKEN_DT":"7/18/2002","CONC":"2.185","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-07-18"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":1,"firstDate":"2002-05-09","lastDate":"2002-05-09","metrics":{"linkedIssuances":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2001-10-09","lastDate":"2001-10-09","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":20,"firstDate":"2001-11-13","lastDate":"2004-08-09","metrics":{"inspectors":23,"recentRows":0,"onSiteHours":262.25,"inspectionHours":481.5,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"853510","EVENT_NO":"4238681","INSPECTION_BEGIN_DT":"08/09/2004","INSPECTION_END_DT":"08/09/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-08-09"},{"SOURCE_ROW_NUMBER":"173323","EVENT_NO":"4238671","INSPECTION_BEGIN_DT":"04/12/2004","INSPECTION_END_DT":"06/03/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"2.25","sourceDate":"2004-04-12"},{"SOURCE_ROW_NUMBER":"450561","EVENT_NO":"4221844","INSPECTION_BEGIN_DT":"01/14/2003","INSPECTION_END_DT":"01/14/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"0","SUM_TOTAL_INSP_HOURS":"0","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2003-01-14"},{"SOURCE_ROW_NUMBER":"984033","EVENT_NO":"4221258","INSPECTION_BEGIN_DT":"10/01/2002","INSPECTION_END_DT":"11/14/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"52","SUM_TOTAL_ON_SITE_HOURS":"24","sourceDate":"2002-10-01"},{"SOURCE_ROW_NUMBER":"70839","EVENT_NO":"4238608","INSPECTION_BEGIN_DT":"09/17/2002","INSPECTION_END_DT":"09/17/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"1","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"873628","EVENT_NO":"4234087","INSPECTION_BEGIN_DT":"08/29/2002","INSPECTION_END_DT":"08/30/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"16","SUM_TOTAL_ON_SITE_HOURS":"10","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"168894","EVENT_NO":"4238605","INSPECTION_BEGIN_DT":"08/26/2002","INSPECTION_END_DT":"09/26/2002","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"75","SUM_TOTAL_ON_SITE_HOURS":"45.5","sourceDate":"2002-08-26"},{"SOURCE_ROW_NUMBER":"1046091","EVENT_NO":"4219239","INSPECTION_BEGIN_DT":"08/22/2002","INSPECTION_END_DT":"08/28/2002","ACTIVITY_CODE":"CDA","ACTIVITY":"ROOF CONTROL SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"42","SUM_TOTAL_ON_SITE_HOURS":"22","sourceDate":"2002-08-22"},{"SOURCE_ROW_NUMBER":"508359","EVENT_NO":"4221794","INSPECTION_BEGIN_DT":"05/29/2002","INSPECTION_END_DT":"06/05/2002","ACTIVITY_CODE":"BAD","ACTIVITY":"CODE-A-PHONE SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"17","SUM_TOTAL_ON_SITE_HOURS":"11","sourceDate":"2002-05-29"},{"SOURCE_ROW_NUMBER":"397541","EVENT_NO":"4221439","INSPECTION_BEGIN_DT":"05/10/2002","INSPECTION_END_DT":"06/04/2002","ACTIVITY_CODE":"CDB","ACTIVITY":"ACCIDENT PREVENTION SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"14","SUM_TOTAL_ON_SITE_HOURS":"7.5","sourceDate":"2002-05-10"},{"SOURCE_ROW_NUMBER":"468260","EVENT_NO":"4234053","INSPECTION_BEGIN_DT":"04/23/2002","INSPECTION_END_DT":"04/25/2002","ACTIVITY_CODE":"BBB","ACTIVITY":"NOISE TECHNICAL INVESTIGATION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2002-04-23"},{"SOURCE_ROW_NUMBER":"329642","EVENT_NO":"4234052","INSPECTION_BEGIN_DT":"04/23/2002","INSPECTION_END_DT":"04/25/2002","ACTIVITY_CODE":"BAB","ACTIVITY":"RESP DUST TECH INSP - U. G. MINES","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"11","SUM_TOTAL_ON_SITE_HOURS":"8","sourceDate":"2002-04-23"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":14,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2004-Q3":{"hours":0,"employees":0,"production":0},"2004-Q2":{"hours":0,"employees":0,"production":0},"2003-Q1":{"hours":0,"employees":0,"production":0},"2002-Q4":{"hours":0,"employees":0,"production":0},"2002-Q3":{"hours":16537,"employees":25,"production":62594},"2002-Q2":{"hours":21884,"employees":33,"production":129067},"2002-Q1":{"hours":8061,"employees":13,"production":36870},"2001-Q2":{"hours":0,"employees":0,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":2,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":46482,"employees":23,"production":228531}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":1,"firstDate":"2002-04-23","lastDate":"2002-04-23","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":15,"pelDoseTotal":5},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"76611","EVENT_NO":"4234053","SURVEY_DATE":"04/23/2002","OCCUPATION_CD_DESC":"LABORER/BLACKSMITH","MACHINE_CD":"40","MANUFACTURER_CD":"119","ACT_DOSE_85":"15","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2002-04-23"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":5,"firstDate":"2002-04-23","lastDate":"2002-08-29","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":16,"validSamples":5,"quartzPctTotal":44.3},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"60442","CASSETTE_NO":"57434714","SAMPLE_DT":"08/29/2002","QUARTZ_PCT":"02.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-08-29"},{"SOURCE_ROW_NUMBER":"141028","CASSETTE_NO":"50639892","SAMPLE_DT":"06/11/2002","QUARTZ_PCT":"11.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-06-11"},{"SOURCE_ROW_NUMBER":"3258","CASSETTE_NO":"50639834","SAMPLE_DT":"05/23/2002","QUARTZ_PCT":"07.8","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-05-23"},{"SOURCE_ROW_NUMBER":"84608","CASSETTE_NO":"57423235","SAMPLE_DT":"04/23/2002","QUARTZ_PCT":"16.0","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-04-23"},{"SOURCE_ROW_NUMBER":"52102","CASSETTE_NO":"57423227","SAMPLE_DT":"04/23/2002","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-04-23"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":48,"firstDate":"2001-11-14","lastDate":"2002-11-05","metrics":{"ss":18,"amountDue":3898,"contested":1,"amountPaid":3767,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":4067},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1002247","VIOLATION_NO":"7541208","VIOLATION_ISSUE_DT":"11/05/2002","SIG_SUB":"N","PART_SECTION":"77.1713(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"0","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"11/14/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-11-05"},{"SOURCE_ROW_NUMBER":"1002245","VIOLATION_NO":"7510288","VIOLATION_ISSUE_DT":"11/05/2002","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"11/13/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-11-05"},{"SOURCE_ROW_NUMBER":"1002246","VIOLATION_NO":"7541207","VIOLATION_ISSUE_DT":"11/04/2002","SIG_SUB":"Y","PART_SECTION":"77.208(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"2","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"02/12/2003","PROPOSED_PENALTY":"113","AMOUNT_DUE":"113","AMOUNT_PAID":"113","CONTESTED_IND":"N","sourceDate":"2002-11-04"},{"SOURCE_ROW_NUMBER":"1002244","VIOLATION_NO":"7510833","VIOLATION_ISSUE_DT":"09/17/2002","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1002243","VIOLATION_NO":"7510832","VIOLATION_ISSUE_DT":"09/17/2002","SIG_SUB":"Y","PART_SECTION":"77.1605(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2002","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"104","CONTESTED_IND":"N","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1002242","VIOLATION_NO":"7510831","VIOLATION_ISSUE_DT":"09/17/2002","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1002241","VIOLATION_NO":"7510830","VIOLATION_ISSUE_DT":"09/17/2002","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2002","PROPOSED_PENALTY":"76","AMOUNT_DUE":"76","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1002240","VIOLATION_NO":"7510829","VIOLATION_ISSUE_DT":"09/17/2002","SIG_SUB":"N","PART_SECTION":"77.1104","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/26/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1002239","VIOLATION_NO":"7510828","VIOLATION_ISSUE_DT":"09/17/2002","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2002","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"104","CONTESTED_IND":"N","sourceDate":"2002-09-17"},{"SOURCE_ROW_NUMBER":"1002238","VIOLATION_NO":"7510823","VIOLATION_ISSUE_DT":"09/11/2002","SIG_SUB":"Y","PART_SECTION":"77.1109(c)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2002","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"104","CONTESTED_IND":"N","sourceDate":"2002-09-11"},{"SOURCE_ROW_NUMBER":"1002237","VIOLATION_NO":"7510822","VIOLATION_ISSUE_DT":"09/11/2002","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2002","PROPOSED_PENALTY":"104","AMOUNT_DUE":"104","AMOUNT_PAID":"104","CONTESTED_IND":"N","sourceDate":"2002-09-11"},{"SOURCE_ROW_NUMBER":"1002236","VIOLATION_NO":"7510821","VIOLATION_ISSUE_DT":"09/11/2002","SIG_SUB":"N","PART_SECTION":"77.410","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/17/2002","PROPOSED_PENALTY":"55","AMOUNT_DUE":"55","AMOUNT_PAID":"55","CONTESTED_IND":"N","sourceDate":"2002-09-11"}]}],"safety":{"href":"/api/v1/mines/1518455/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518455/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1713","heading":"Daily inspection of surface coal mine; certified person; reports of inspection.","id":"77.1713","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-R/section-77.1713","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) At least once during each working shift, or more often if necessary for safety, each active working area and each active surface installation shall be examined by a certified person designated by the operator to conduct such examinations for hazardous conditions and any hazardous conditions noted during such examinations shall be reported to the operator and shall be corrected by the operator.\n\n(b) If any hazardous condition noted during an examination conducted in accordance with paragraph (a) of this section creates an imminent danger, the person conducting such examination shall notify the operator and the operator shall withdraw all persons from the area affected, except those persons referred to in section 104(d) of the Act, until the danger is abated.\n\n(c) After each examination conducted in accordance with the provisions of paragraph (a) of this section, each certified person who conducted all or any part of the examination required shall enter with ink or indelible pencil in a book approved by the Secretary the date and a report of the condition of the mine or any area of the mine which he has inspected together with a report of the nature and location of any hazardous condition found to be present at the mine. The book in which such entries are made shall be kept in an area at the mine designated by the operator to minimize the danger of destruction by fire or other hazard.\n\n(d) All examination reports recorded in accordance with the provisions of paragraph (c) of this section shall include a report of the action taken to abate hazardous conditions and shall be signed or countersigned each day by at least one of the following persons:\n\n(1) The surface mine foreman;\n\n(2) The assistant superintendent of the mine;\n\n(3) The superintendent of the mine;\n\n(4) The person designated by the operator as responsible for health and safety at the mine; or,\n\n(5) An equivalent mine official.\n\n(Pub. L. No. 96-511, 94 Stat. 2812 (44 U.S.C. 3501 et seq.))\n\n[36 FR 9364, May 22, 1971, as amended at 60 FR 33723, June 29, 1995; 63 FR 58613, Oct. 30, 1998]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.208","heading":"Storage of materials.","id":"77.208","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-C/section-77.208","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"C","subpartHeading":"Subpart C—Surface Installations","text":"(a) Materials shall be stored and stacked in a manner which minimizes stumbling or fall-of-material hazards.\n\n(b) Materials that can create hazards if accidentally liberated from their containers shall be stored in a manner that minimizes the dangers.\n\n(c) Containers holding hazardous materials must be of a type approved for such use by recognized agencies.\n\n(d) Compressed and liquid gas cylinders shall be secured in a safe manner.\n\n(e) Valves on compressed gas cylinders shall be protected by covers when being transported or stored, and by a safe location when the cylinders are in use.\n\n[36 FR 9364, May 22, 1971, as amended at 67 FR 42389, June 21, 2002]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":5},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1605","heading":"Loading and haulage equipment; installations.","id":"77.1605","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-Q/section-77.1605","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"Q","subpartHeading":"Subpart Q—Loading and Haulage","text":"(a) Cab windows shall be of safety glass or equivalent, in good condition and shall be kept clean.\n\n(b) Mobile equipment shall be equipped with adequate brakes, and all trucks and front-end loaders shall also be equipped with parking brakes.\n\n(c) Positive-action type brakes shall be provided on aerial tramways.\n\n(d) Mobile equipment shall be provided with audible warning devices. Lights shall be provided on both ends when required.\n\n(e) Guard nets or other suitable protection shall be provided where tramways pass over roadways, walkways, or buildings.\n\n(f) Guards shall be installed to prevent swaying buckets from hitting towers.\n\n(g) Aerial tramway cable connections shall be designed to offer minimum obstruction to the passage of wheels.\n\n(h) Rocker-bottom or bottom-dump cars shall be equipped with positive locking devices, or other suitable devices.\n\n(i) Ramps and dumps shall be of solid construction, of ample width, have ample clearance and headroom, and be kept reasonably free of spillage.\n\n(j) Chute-loading installations shall be designed so that the men pulling chutes are not required to be in a hazardous position during loading operations.\n\n(k) Berms or guards shall be provided on the outer bank of elevated roadways.\n\n(l) Berms, bumper blocks, safety hooks, or similar means shall be provided to prevent overtravel and overturning at dumping locations.\n\n(m) Roadbeds, rails, joints, switches, frogs, and other elements on railroads shall be designed, installed, and maintained in a safe manner consistent with the speed and type of haulage.\n\n(n) Where practicable, a minimum of 30 inches continuous clearance from the farthest projection of moving railroad equipment shall be provided on at least one side of the tracks; all places where it is not possible to provide 30-inch clearance shall be marked conspicuously.\n\n(o) Track guardrails, lead rails, and frogs shall be protected or blocked so as to prevent a person's foot from becoming wedged.\n\n(p) Positive-acting stop-blocks, derail devices, track skates, or other adequate means shall be installed wherever necessary to protect persons from runaway or moving railroad equipment.\n\n(q) Switch throws shall be installed so as to provide adequate clearance for switchmen.\n\n(r) Where necessary, bumper blocks or the equivalent shall be provided at all track dead ends.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1104","heading":"Accumulations of combustible materials.","id":"77.1104","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1104","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Combustible materials, grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create a fire hazard.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.1109","heading":"Quantity and location of firefighting equipment.","id":"77.1109","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-L/section-77.1109","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"Preparation plants, dryer plants, tipples, drawoff tunnels, shops, and other surface installations shall be equipped with the following firefighting equipment.\n\n(a) Each structure presenting a fire hazard shall be provided with portable fire extinguishers commensurate with the potential fire hazard at the structure in accordance with the recommendations of the National Fire Protection Association.\n\n(b) Preparation plants shall be equipped with waterlines, with outlet valves on each floor, and with sufficient fire hose to project a water stream to any point in the plant. However, where freezing conditions exist or water is not available, a 125-pound multipurpose dry powder extinguisher may be substituted for the purposes of this paragraph (b) for each 2,500 square feet of floor space in a wooden or other flammable structure, or for each 5,000 square feet of floor space in a metal, concrete-block, or other type of non-flammable construction.\n\n(c)(1) Mobile equipment, including trucks, front-end loaders, bulldozers, portable welding units, and augers, shall be equipped with at least one portable fire extinguisher.\n\n(2) Power shovels, draglines, and other large equipment shall be equipped with at least one portable fire extinguisher; however, additional fire extinguishers may be required by an authorized representative of the Secretary.\n\n(3) Auxiliary equipment such as portable drills, sweepers, and scrapers, when operated more than 600 feet from equipment required to have portable fire extinguishers, shall be equipped with at least one fire extinguisher.\n\n(d) Fire extinguishers shall be provided at permanent electrical installations commensurate with the potential fire hazard at such installation in accordance with the recommendations of the National Fire Protection Association.\n\n(e) Two portable fire extinguishers, or the equivalent, shall be provided at each of the following combustible liquid storage installations:\n\n(1) Near each above ground or unburied combustible liquid storage station; and,\n\n(2) Near the transfer pump of each buried combustible liquid storage tank.\n\n(f) Vehicles transporting explosives and blasting agents shall be equipped with fire protection as recommended in Code 495, section 20, National Fire Protection Association Handbook, 12th Edition, 1962.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518455","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}