{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518440","name":"No 6","status":"Abandoned","status_date":"2007-04-24","mine_type":"Underground","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Knox","nearest_town":"Corbin","operator_id":"P21851","operator_name":"Mallie Coal Company Incorporated","controller_id":"C11918","controller_name":"Jerry M  Grant","district":"C07","office":"Barbourville KY Field Office","employees":0,"latitude":36.838333,"longitude":-84.0325},"coverage":{"contributingSources":13,"registeredSources":20,"sourceRows":612},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518440","name":"No 6"},"operator":{"type":"operator","id":"P21851","name":"Mallie Coal Company Incorporated"},"controller":{"type":"controller","id":"C11918","name":"Jerry M  Grant"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C11918","name":"Jerry M  Grant"},"object":{"type":"mine","id":"1518440","name":"No 6"},"validFrom":"1992-03-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518440|C11918|1992-03-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P21851","name":"Mallie Coal Company Incorporated"},"object":{"type":"mine","id":"1518440","name":"No 6"},"validFrom":"2001-09-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518440|P21851|2001-09-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C11918","name":"Jerry M  Grant"},"object":{"type":"operator","id":"P21851","name":"Mallie Coal Company Incorporated"},"validFrom":"2001-09-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518440","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518440|P21851|2001-09-01|C11918|1992-03-01|85699"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-04-24","lastDate":"2007-04-24","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":59,"firstDate":"2002-10-16","lastDate":"2007-03-12","metrics":{"ss":12,"delinquent":54,"recentRows":0,"paidPenalty":4080,"proposedPenalty":4080,"currentAssessment":4080},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1137302","VIOLATION_NO":"7553625","ISSUE_DT":"03/12/2007","CFR_STANDARD_CD":"75.330(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-12"},{"SOURCE_ROW_NUMBER":"1137301","VIOLATION_NO":"7553624","ISSUE_DT":"03/05/2007","CFR_STANDARD_CD":"75.330(b)(2)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-05"},{"SOURCE_ROW_NUMBER":"1137300","VIOLATION_NO":"7553623","ISSUE_DT":"03/05/2007","CFR_STANDARD_CD":"77.410(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-05"},{"SOURCE_ROW_NUMBER":"1137299","VIOLATION_NO":"7553622","ISSUE_DT":"03/05/2007","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2007-03-05"},{"SOURCE_ROW_NUMBER":"1137282","VIOLATION_NO":"7553586","ISSUE_DT":"10/30/2006","CFR_STANDARD_CD":"75.518","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"1137281","VIOLATION_NO":"7553585","ISSUE_DT":"10/30/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"1137280","VIOLATION_NO":"7553584","ISSUE_DT":"10/30/2006","CFR_STANDARD_CD":"75.503","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"1137267","VIOLATION_NO":"7553578","ISSUE_DT":"09/19/2006","CFR_STANDARD_CD":"75.370(a)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-19"},{"SOURCE_ROW_NUMBER":"1137266","VIOLATION_NO":"7553577","ISSUE_DT":"09/12/2006","CFR_STANDARD_CD":"75.1107-16(b)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"1137265","VIOLATION_NO":"7553576","ISSUE_DT":"09/12/2006","CFR_STANDARD_CD":"75.330(b)(1)(i)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"91.00","CURRENT_ASSESSMENT_AMT":"91.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"1137264","VIOLATION_NO":"7553575","ISSUE_DT":"09/12/2006","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"72.00","CURRENT_ASSESSMENT_AMT":"72.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"1137263","VIOLATION_NO":"7553574","ISSUE_DT":"09/12/2006","CFR_STANDARD_CD":"48.31(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Order","PROPOSED_PENALTY_AMT":"178.00","CURRENT_ASSESSMENT_AMT":"178.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-09-12"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":292,"firstDate":"2002-10-23","lastDate":"2007-03-14","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":9,"validSamples":283,"maxConcentration":1.934,"concentrationTotal":87.767},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1177584","CASS_NUM":"50883278","SMP_TAKEN_DT":"3/14/2007","CONC":".35","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-14"},{"SOURCE_ROW_NUMBER":"826831","CASS_NUM":"50883294","SMP_TAKEN_DT":"3/13/2007","CONC":".452","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-13"},{"SOURCE_ROW_NUMBER":"496700","CASS_NUM":"50883299","SMP_TAKEN_DT":"3/9/2007","CONC":".613","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-09"},{"SOURCE_ROW_NUMBER":"9838","CASS_NUM":"50883318","SMP_TAKEN_DT":"3/8/2007","CONC":".497","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-08"},{"SOURCE_ROW_NUMBER":"365958","CASS_NUM":"50883293","SMP_TAKEN_DT":"3/7/2007","CONC":".379","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-07"},{"SOURCE_ROW_NUMBER":"1399527","CASS_NUM":"57698775","SMP_TAKEN_DT":"3/6/2007","CONC":"1.934","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"COAL DRILL OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"1213768","CASS_NUM":"57698783","SMP_TAKEN_DT":"3/6/2007","CONC":".868","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"1110999","CASS_NUM":"57698763","SMP_TAKEN_DT":"3/6/2007","CONC":".314","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"437713","CASS_NUM":"57698778","SMP_TAKEN_DT":"3/6/2007","CONC":"1.496","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"SCOOP CAR OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"429029","CASS_NUM":"57698806","SMP_TAKEN_DT":"3/6/2007","CONC":"1.328","SMP_TYPE_CD_DESC":"NON DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"MINE FOREMAN/MINE MANAGER","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"253507","CASS_NUM":"57698805","SMP_TAKEN_DT":"3/6/2007","CONC":".181","SMP_TYPE_CD_DESC":"DESIGNATED AREA","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"201797","CASS_NUM":"57698798","SMP_TAKEN_DT":"3/6/2007","CONC":".23","SMP_TYPE_CD_DESC":"INTAKE AIR","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"OCCUPATION CODE NOT FOUND","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2007-03-06"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":45,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":4,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2001-09-01","lastDate":"2001-09-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":48,"firstDate":"2002-10-16","lastDate":"2007-08-16","metrics":{"inspectors":61,"recentRows":0,"onSiteHours":912.5,"inspectionHours":1474.5,"inspectionSamples":35},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"563114","EVENT_NO":"4238169","INSPECTION_BEGIN_DT":"08/16/2007","INSPECTION_END_DT":"08/20/2007","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"12","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2007-08-16"},{"SOURCE_ROW_NUMBER":"782546","EVENT_NO":"4238333","INSPECTION_BEGIN_DT":"02/26/2007","INSPECTION_END_DT":"03/28/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"48","SUM_TOTAL_ON_SITE_HOURS":"31.5","sourceDate":"2007-02-26"},{"SOURCE_ROW_NUMBER":"942891","EVENT_NO":"4238324","INSPECTION_BEGIN_DT":"10/16/2006","INSPECTION_END_DT":"11/22/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"120","SUM_TOTAL_ON_SITE_HOURS":"77","sourceDate":"2006-10-16"},{"SOURCE_ROW_NUMBER":"36093","EVENT_NO":"4238321","INSPECTION_BEGIN_DT":"09/11/2006","INSPECTION_END_DT":"09/28/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"70","SUM_TOTAL_ON_SITE_HOURS":"46.5","sourceDate":"2006-09-11"},{"SOURCE_ROW_NUMBER":"1158993","EVENT_NO":"4237949","INSPECTION_BEGIN_DT":"05/09/2006","INSPECTION_END_DT":"05/25/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"41","SUM_TOTAL_ON_SITE_HOURS":"22","sourceDate":"2006-05-09"},{"SOURCE_ROW_NUMBER":"438788","EVENT_NO":"4238131","INSPECTION_BEGIN_DT":"01/10/2006","INSPECTION_END_DT":"03/31/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"114","SUM_TOTAL_ON_SITE_HOURS":"92","sourceDate":"2006-01-10"},{"SOURCE_ROW_NUMBER":"180601","EVENT_NO":"4238129","INSPECTION_BEGIN_DT":"11/17/2005","INSPECTION_END_DT":"12/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"40","SUM_TOTAL_ON_SITE_HOURS":"28","sourceDate":"2005-11-17"},{"SOURCE_ROW_NUMBER":"299057","EVENT_NO":"4238303","INSPECTION_BEGIN_DT":"07/05/2005","INSPECTION_END_DT":"09/30/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"72","SUM_TOTAL_ON_SITE_HOURS":"48","sourceDate":"2005-07-05"},{"SOURCE_ROW_NUMBER":"613235","EVENT_NO":"4237598","INSPECTION_BEGIN_DT":"05/02/2005","INSPECTION_END_DT":"06/09/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"29","SUM_TOTAL_ON_SITE_HOURS":"18","sourceDate":"2005-05-02"},{"SOURCE_ROW_NUMBER":"1029728","EVENT_NO":"4231929","INSPECTION_BEGIN_DT":"01/26/2005","INSPECTION_END_DT":"03/31/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"100","SUM_TOTAL_ON_SITE_HOURS":"78.5","sourceDate":"2005-01-26"},{"SOURCE_ROW_NUMBER":"801854","EVENT_NO":"4219300","INSPECTION_BEGIN_DT":"10/04/2004","INSPECTION_END_DT":"12/22/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"3","SUM_TOTAL_INSP_HOURS":"46","SUM_TOTAL_ON_SITE_HOURS":"26","sourceDate":"2004-10-04"},{"SOURCE_ROW_NUMBER":"939264","EVENT_NO":"4209867","INSPECTION_BEGIN_DT":"07/27/2004","INSPECTION_END_DT":"09/30/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"101","SUM_TOTAL_ON_SITE_HOURS":"62","sourceDate":"2004-07-27"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":36,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2007-Q2":{"hours":875,"employees":5,"production":316},"2007-Q1":{"hours":2100,"employees":5,"production":3363},"2006-Q4":{"hours":2100,"employees":5,"production":3202},"2006-Q3":{"hours":1900,"employees":5,"production":3357},"2006-Q2":{"hours":2340,"employees":5,"production":2806},"2006-Q1":{"hours":2560,"employees":5,"production":3219},"2005-Q4":{"hours":1920,"employees":4,"production":3127},"2005-Q3":{"hours":1760,"employees":4,"production":3531},"2005-Q2":{"hours":2000,"employees":5,"production":4174},"2005-Q1":{"hours":2400,"employees":5,"production":4523},"2004-Q4":{"hours":1900,"employees":5,"production":3229},"2004-Q3":{"hours":3000,"employees":5,"production":4797}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":12,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2002":{"hours":1200,"employees":4,"production":1587},"2003":{"hours":6619,"employees":5,"production":17142},"2004":{"hours":6340,"employees":5,"production":10807},"2005":{"hours":8080,"employees":5,"production":15355},"2006":{"hours":8900,"employees":5,"production":12584},"2007":{"hours":2975,"employees":5,"production":3679}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":47,"firstDate":"2003-01-02","lastDate":"2007-03-06","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":2056,"pelDoseTotal":1393},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"76430","EVENT_NO":"4238333","SURVEY_DATE":"03/06/2007","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"41","PEL_DOSE_90":"25","SURVEY_TYPE":"I","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"76429","EVENT_NO":"4238333","SURVEY_DATE":"03/06/2007","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"120","ACT_DOSE_85":"63","PEL_DOSE_90":"50","SURVEY_TYPE":"I","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"76428","EVENT_NO":"4238333","SURVEY_DATE":"03/06/2007","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"120","ACT_DOSE_85":"57","PEL_DOSE_90":"51","SURVEY_TYPE":"I","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"76427","EVENT_NO":"4238333","SURVEY_DATE":"03/06/2007","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"074","ACT_DOSE_85":"43","PEL_DOSE_90":"27","SURVEY_TYPE":"I","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"76426","EVENT_NO":"4238321","SURVEY_DATE":"09/20/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"074","ACT_DOSE_85":"57","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"76425","EVENT_NO":"4238321","SURVEY_DATE":"09/20/2006","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"119","ACT_DOSE_85":"62","PEL_DOSE_90":"53","SURVEY_TYPE":"I","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"76424","EVENT_NO":"4238321","SURVEY_DATE":"09/20/2006","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"074","ACT_DOSE_85":"52","PEL_DOSE_90":"46","SURVEY_TYPE":"I","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"76423","EVENT_NO":"4238321","SURVEY_DATE":"09/20/2006","OCCUPATION_CD_DESC":"COAL DRILL OPERATOR","MACHINE_CD":"05","MANUFACTURER_CD":"120","ACT_DOSE_85":"14","PEL_DOSE_90":"10","SURVEY_TYPE":"I","sourceDate":"2006-09-20"},{"SOURCE_ROW_NUMBER":"76422","EVENT_NO":"4237598","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"HIGHLIFT OPERATOR/FRONT END LOADER","MACHINE_CD":"18","MANUFACTURER_CD":"119","ACT_DOSE_85":"12","PEL_DOSE_90":"5","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"76421","EVENT_NO":"4237598","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"ROOF BOLTER (SINGLE HEAD)","MACHINE_CD":"30","MANUFACTURER_CD":"119","ACT_DOSE_85":"89","PEL_DOSE_90":"77","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"76420","EVENT_NO":"4237598","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"074","ACT_DOSE_85":"65","PEL_DOSE_90":"47","SURVEY_TYPE":"I","sourceDate":"2005-05-16"},{"SOURCE_ROW_NUMBER":"76419","EVENT_NO":"4237598","SURVEY_DATE":"05/16/2005","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"074","ACT_DOSE_85":"56","PEL_DOSE_90":"44","SURVEY_TYPE":"I","sourceDate":"2005-05-16"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":6,"firstDate":"2002-12-20","lastDate":"2007-03-06","metrics":{"recentRows":0,"voidSamples":0,"maxQuartzPct":3.5,"validSamples":6,"quartzPctTotal":10.9},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"14687","CASSETTE_NO":"57698775","SAMPLE_DT":"03/06/2007","QUARTZ_PCT":"01.9","OCC_CODE_DESC":"COAL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2007-03-06"},{"SOURCE_ROW_NUMBER":"124562","CASSETTE_NO":"57678348","SAMPLE_DT":"11/21/2006","QUARTZ_PCT":"03.5","OCC_CODE_DESC":"COAL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2006-11-21"},{"SOURCE_ROW_NUMBER":"30012","CASSETTE_NO":"57607801","SAMPLE_DT":"08/23/2005","QUARTZ_PCT":"02.5","OCC_CODE_DESC":"COAL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-08-23"},{"SOURCE_ROW_NUMBER":"81801","CASSETTE_NO":"57591653","SAMPLE_DT":"07/28/2004","QUARTZ_PCT":"00.3","OCC_CODE_DESC":"COAL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-07-28"},{"SOURCE_ROW_NUMBER":"121414","CASSETTE_NO":"57595457","SAMPLE_DT":"05/19/2004","QUARTZ_PCT":"01.6","OCC_CODE_DESC":"COAL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-05-19"},{"SOURCE_ROW_NUMBER":"30088","CASSETTE_NO":"57470633","SAMPLE_DT":"12/20/2002","QUARTZ_PCT":"01.1","OCC_CODE_DESC":"COAL DRILL OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2002-12-20"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":60,"firstDate":"2002-10-16","lastDate":"2007-03-12","metrics":{"ss":12,"amountDue":4080,"contested":0,"amountPaid":4080,"recentRows":0,"section104d":0,"unterminated":1,"proposedPenalty":4080},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1001502","VIOLATION_NO":"7553625","VIOLATION_ISSUE_DT":"03/12/2007","SIG_SUB":"N","PART_SECTION":"75.330(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/12/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-03-12"},{"SOURCE_ROW_NUMBER":"1001501","VIOLATION_NO":"7553624","VIOLATION_ISSUE_DT":"03/05/2007","SIG_SUB":"N","PART_SECTION":"75.330(b)(2)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/05/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-03-05"},{"SOURCE_ROW_NUMBER":"1001500","VIOLATION_NO":"7553623","VIOLATION_ISSUE_DT":"03/05/2007","SIG_SUB":"N","PART_SECTION":"77.410(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"NoLikelihood","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/05/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-03-05"},{"SOURCE_ROW_NUMBER":"1001499","VIOLATION_NO":"7553622","VIOLATION_ISSUE_DT":"03/05/2007","SIG_SUB":"N","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"03/12/2007","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2007-03-05"},{"SOURCE_ROW_NUMBER":"1001540","VIOLATION_NO":"7553586","VIOLATION_ISSUE_DT":"10/30/2006","SIG_SUB":"N","PART_SECTION":"75.518","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/30/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"1001539","VIOLATION_NO":"7553585","VIOLATION_ISSUE_DT":"10/30/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/30/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"1001538","VIOLATION_NO":"7553584","VIOLATION_ISSUE_DT":"10/30/2006","SIG_SUB":"N","PART_SECTION":"75.503","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"10/30/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-10-30"},{"SOURCE_ROW_NUMBER":"1001530","VIOLATION_NO":"7553578","VIOLATION_ISSUE_DT":"09/19/2006","SIG_SUB":"N","PART_SECTION":"75.370(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/19/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-19"},{"SOURCE_ROW_NUMBER":"1001529","VIOLATION_NO":"7553577","VIOLATION_ISSUE_DT":"09/12/2006","SIG_SUB":"N","PART_SECTION":"75.1107-16(b)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/19/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"1001528","VIOLATION_NO":"7553576","VIOLATION_ISSUE_DT":"09/12/2006","SIG_SUB":"Y","PART_SECTION":"75.330(b)(1)(i)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/12/2006","PROPOSED_PENALTY":"91","AMOUNT_DUE":"91","AMOUNT_PAID":"91","CONTESTED_IND":"N","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"1001527","VIOLATION_NO":"7553575","VIOLATION_ISSUE_DT":"09/12/2006","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/27/2006","PROPOSED_PENALTY":"72","AMOUNT_DUE":"72","AMOUNT_PAID":"72","CONTESTED_IND":"N","sourceDate":"2006-09-12"},{"SOURCE_ROW_NUMBER":"1001526","VIOLATION_NO":"7553574","VIOLATION_ISSUE_DT":"09/12/2006","SIG_SUB":"Y","PART_SECTION":"48.31(a)","CIT_ORD_SAFE":"Order","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"09/12/2006","PROPOSED_PENALTY":"178","AMOUNT_DUE":"178","AMOUNT_PAID":"178","CONTESTED_IND":"N","sourceDate":"2006-09-12"}]}],"safety":{"href":"/api/v1/mines/1518440/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518440/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.330","heading":"Face ventilation control devices.","id":"75.330","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.330","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) Brattice cloth, ventilation tubing and other face ventilation control devices shall be made of flame-resistant material approved by MSHA.\n\n(b)(1) Ventilation control devices shall be used to provide ventilation to dilute, render harmless, and to carry away flammable, explosive, noxious, and harmful gases, dusts, smoke, and fumes—\n\n(i) To each working face from which coal is being cut, mined, drilled for blasting, or loaded; and\n\n(ii) To any other working places as required by the approved ventilation plan.\n\n(2) These devices shall be installed at a distance no greater than 10 feet from the area of deepest penetration to which any portion of the face has been advanced unless an alternative distance is specified and approved in the ventilation plan. Alternative distances specified shall be capable of maintaining concentrations of respirable dust, methane, and other harmful gases, in accordance with the levels specified in the applicable sections of this chapter.\n\n(c) When the line brattice or any other face ventilation control device is damaged to an extent that ventilation of the working face is inadequate, production activities in the working place shall cease until necessary repairs are made and adequate ventilation is restored.\n\n[61 FR 9828, Mar. 11, 1996; 61 FR 29288, June 10, 1996]","occurrenceCount":3},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":2},{"chapter":"I","heading":"Electric equipment and circuits; overload and short circuit protection.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.518","part":"75","subchapter":"O","subpart":"F","id":"75.518","citation":"30 CFR 75.518","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.503","heading":"Permissible electric face equipment; maintenance.","id":"75.503","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-F/section-75.503","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"[Statutory Provisions]\n\nThe operator of each coal mine shall maintain in permissible condition all electric face equipment required by §§ 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1107-16","heading":"Inspection of fire suppression devices.","id":"75.1107-16","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-L/section-75.1107-16","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"L","subpartHeading":"Subpart L—Fire Protection","text":"(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.\n\n(b) Each fire suppression device shall be tested and maintained in accordance with the requirements specified in the appropriate National Fire Code listed as follows for the type and kind of device used:\n\nNational Fire Code No. 11A “High Expansion Foam Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire Code No. 72A “Local Protective Signaling Systems” (NFPA No. 72A—1967). National Fire Code No. 198 “Care of Fire Hose” (NFPA No. 198—1969).\n\n(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.\n\n[37 FR 15304, July 29, 1972, as amended at 60 FR 33723, June 29, 1995]","occurrenceCount":1},{"chapter":"I","heading":"Hazard training.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-H/part-48/subpart-B/section-48.31","part":"48","subchapter":"H","subpart":"B","id":"48.31","citation":"30 CFR 48.31","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER H—EDUCATION AND TRAINING","partHeading":"PART 48—TRAINING AND RETRAINING OF MINERS","subpartHeading":"","text":null,"occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518440","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}