{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518424","name":"#2 Riverway Terminals","status":"Abandoned","status_date":"2007-10-09","mine_type":"Facility","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Boyd","nearest_town":"Catlettsburg","operator_id":"P24423","operator_name":"TTI Synfuel, Inc.","controller_id":"C15940","controller_name":"TTI Technologies Inc","district":"C07","office":"Hazard KY Field Office","employees":0,"latitude":38.321666,"longitude":-82.578055},"coverage":{"contributingSources":12,"registeredSources":20,"sourceRows":112},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518424","name":"#2 Riverway Terminals"},"operator":{"type":"operator","id":"P24423","name":"TTI Synfuel, Inc."},"controller":{"type":"controller","id":"C15940","name":"TTI Technologies Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C15940","name":"TTI Technologies Inc"},"object":{"type":"mine","id":"1518424","name":"#2 Riverway Terminals"},"validFrom":"2000-06-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518424|C15940|2000-06-01|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P24423","name":"TTI Synfuel, Inc."},"object":{"type":"mine","id":"1518424","name":"#2 Riverway Terminals"},"validFrom":"2001-08-01","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518424|P24423|2001-08-01|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C15940","name":"TTI Technologies Inc"},"object":{"type":"operator","id":"P24423","name":"TTI Synfuel, Inc."},"validFrom":"2001-08-01","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518424","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518424|P24423|2001-08-01|C15940|2000-06-01|97737"}}],"coverage":{"historyRecords":1,"edgeCount":3,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2007-10-09","lastDate":"2007-10-09","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":3,"firstDate":"2006-03-22","lastDate":"2006-03-29","metrics":{"ss":2,"delinquent":3,"recentRows":0,"paidPenalty":248,"proposedPenalty":308,"currentAssessment":308},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1018094","VIOLATION_NO":"7433630","ISSUE_DT":"03/29/2006","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"1018093","VIOLATION_NO":"7433629","ISSUE_DT":"03/29/2006","CFR_STANDARD_CD":"77.404(a)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"124.00","CURRENT_ASSESSMENT_AMT":"124.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"1018092","VIOLATION_NO":"7433145","ISSUE_DT":"03/22/2006","CFR_STANDARD_CD":"77.502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2006-03-22"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":6,"firstDate":"2002-03-26","lastDate":"2002-06-18","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":0,"validSamples":6,"maxConcentration":0.707,"concentrationTotal":2.14},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1628896","CASS_NUM":"57411609","SMP_TAKEN_DT":"6/18/2002","CONC":".26","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"1275890","CASS_NUM":"57411596","SMP_TAKEN_DT":"6/18/2002","CONC":".368","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CLEANING PLANT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"577963","CASS_NUM":"57411608","SMP_TAKEN_DT":"6/18/2002","CONC":".204","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WATER CIRCUIT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"1651526","CASS_NUM":"57411295","SMP_TAKEN_DT":"3/26/2002","CONC":".096","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"WATER CIRCUIT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"901343","CASS_NUM":"57411284","SMP_TAKEN_DT":"3/26/2002","CONC":".707","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CLEANING PLANT OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-26"},{"SOURCE_ROW_NUMBER":"74840","CASS_NUM":"57411282","SMP_TAKEN_DT":"3/26/2002","CONC":".505","SMP_TYPE_CD_DESC":"NONDESIGNATED WORK POSITION","SMP_USE_CD_DESC":"NOT USED ON INSPECTOR SAMPLES; NOT FOUND ON OPERATOR SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"UTILITY MAN","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2002-03-26"}]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":49,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":15,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":1,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":1,"firstDate":"2001-08-01","lastDate":"2001-08-01","metrics":{"recentRows":0,"currentOperatorTenures":1,"completedOperatorTenures":0},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":19,"firstDate":"2001-09-11","lastDate":"2007-10-09","metrics":{"inspectors":22,"recentRows":0,"onSiteHours":69.5,"inspectionHours":155,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"787759","EVENT_NO":"4190450","INSPECTION_BEGIN_DT":"10/09/2007","INSPECTION_END_DT":"10/09/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"15","SUM_TOTAL_ON_SITE_HOURS":"5","sourceDate":"2007-10-09"},{"SOURCE_ROW_NUMBER":"463304","EVENT_NO":"4189841","INSPECTION_BEGIN_DT":"05/31/2007","INSPECTION_END_DT":"05/31/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2007-05-31"},{"SOURCE_ROW_NUMBER":"529171","EVENT_NO":"4192621","INSPECTION_BEGIN_DT":"03/09/2007","INSPECTION_END_DT":"03/12/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3.25","SUM_TOTAL_ON_SITE_HOURS":".5","sourceDate":"2007-03-09"},{"SOURCE_ROW_NUMBER":"131803","EVENT_NO":"4190154","INSPECTION_BEGIN_DT":"07/12/2006","INSPECTION_END_DT":"07/18/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"0","sourceDate":"2006-07-12"},{"SOURCE_ROW_NUMBER":"575522","EVENT_NO":"4189500","INSPECTION_BEGIN_DT":"04/05/2006","INSPECTION_END_DT":"04/07/2006","ACTIVITY_CODE":"E15","ACTIVITY":"Compliance Follow-up Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2006-04-05"},{"SOURCE_ROW_NUMBER":"226978","EVENT_NO":"4189562","INSPECTION_BEGIN_DT":"03/22/2006","INSPECTION_END_DT":"03/29/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2.75","sourceDate":"2006-03-22"},{"SOURCE_ROW_NUMBER":"229579","EVENT_NO":"4189454","INSPECTION_BEGIN_DT":"08/24/2005","INSPECTION_END_DT":"08/24/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.75","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2005-08-24"},{"SOURCE_ROW_NUMBER":"869231","EVENT_NO":"5847324","INSPECTION_BEGIN_DT":"03/03/2005","INSPECTION_END_DT":"03/15/2005","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2005-03-03"},{"SOURCE_ROW_NUMBER":"118901","EVENT_NO":"4184521","INSPECTION_BEGIN_DT":"07/12/2004","INSPECTION_END_DT":"09/16/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2004-07-12"},{"SOURCE_ROW_NUMBER":"570416","EVENT_NO":"4184131","INSPECTION_BEGIN_DT":"02/23/2004","INSPECTION_END_DT":"03/11/2004","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2004-02-23"},{"SOURCE_ROW_NUMBER":"467163","EVENT_NO":"4183602","INSPECTION_BEGIN_DT":"04/16/2003","INSPECTION_END_DT":"04/22/2003","ACTIVITY_CODE":"AAA","ACTIVITY":"Regular Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"9.5","SUM_TOTAL_ON_SITE_HOURS":"4","sourceDate":"2003-04-16"},{"SOURCE_ROW_NUMBER":"938952","EVENT_NO":"4171106","INSPECTION_BEGIN_DT":"04/14/2003","INSPECTION_END_DT":"04/14/2003","ACTIVITY_CODE":"CAA","ACTIVITY":"SPOT INSPECTION","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"3.5","sourceDate":"2003-04-14"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":8,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2003-Q2":{"hours":128,"employees":1,"production":0},"2003-Q1":{"hours":1831,"employees":6,"production":0},"2002-Q4":{"hours":3156,"employees":7,"production":0},"2002-Q3":{"hours":2827,"employees":6,"production":0},"2002-Q2":{"hours":2591,"employees":4,"production":0},"2002-Q1":{"hours":2367,"employees":8,"production":0},"2001-Q4":{"hours":1029,"employees":7,"production":0},"2001-Q3":{"hours":1080,"employees":5,"production":0}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":3,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":2109,"employees":6,"production":0},"2002":{"hours":10941,"employees":6,"production":0},"2003":{"hours":1959,"employees":4,"production":0}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":3,"firstDate":"2002-06-18","lastDate":"2002-06-18","metrics":{"recentRows":0,"doseOver100":0,"actDoseTotal":134,"pelDoseTotal":47},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"75960","EVENT_NO":"4174828","SURVEY_DATE":"06/18/2002","OCCUPATION_CD_DESC":"CLEANING PLANT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"61","PEL_DOSE_90":"12","SURVEY_TYPE":"I","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"75959","EVENT_NO":"4174828","SURVEY_DATE":"06/18/2002","OCCUPATION_CD_DESC":"WATER CIRCUIT OPERATOR","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"21","PEL_DOSE_90":"11","SURVEY_TYPE":"I","sourceDate":"2002-06-18"},{"SOURCE_ROW_NUMBER":"75958","EVENT_NO":"4174828","SURVEY_DATE":"06/18/2002","OCCUPATION_CD_DESC":"UTILITY MAN","MACHINE_CD":"40","MANUFACTURER_CD":"120","ACT_DOSE_85":"52","PEL_DOSE_90":"24","SURVEY_TYPE":"I","sourceDate":"2002-06-18"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":3,"firstDate":"2006-03-22","lastDate":"2006-03-29","metrics":{"ss":2,"amountDue":308,"contested":0,"amountPaid":248,"recentRows":0,"section104d":0,"unterminated":0,"proposedPenalty":308},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"999874","VIOLATION_NO":"7433630","VIOLATION_ISSUE_DT":"03/29/2006","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/05/2006","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"999873","VIOLATION_NO":"7433629","VIOLATION_ISSUE_DT":"03/29/2006","SIG_SUB":"Y","PART_SECTION":"77.404(a)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"Fatal","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"04/05/2006","PROPOSED_PENALTY":"124","AMOUNT_DUE":"124","AMOUNT_PAID":"124","CONTESTED_IND":"N","sourceDate":"2006-03-29"},{"SOURCE_ROW_NUMBER":"999872","VIOLATION_NO":"7433145","VIOLATION_ISSUE_DT":"03/22/2006","SIG_SUB":"N","PART_SECTION":"77.502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"LowNegligence","TERMINATION_DT":"03/29/2006","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"0","CONTESTED_IND":"N","sourceDate":"2006-03-22"}]}],"safety":{"href":"/api/v1/mines/1518424/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518424/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.404","heading":"Machinery and equipment; operation and maintenance.","id":"77.404","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.404","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately.\n\n(b) Machinery and equipment shall be operated only by persons trained in the use of and authorized to operate such machinery or equipment.\n\n(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.\n\n(d) Machinery shall not be lubricated while in motion where a hazard exists, unless equipped with extended fittings or cups.","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.502","heading":"Electric equipment; examination, testing, and maintenance.","id":"77.502","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-F/section-77.502","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"F","subpartHeading":"Subpart F—Electrical Equipment—General","text":"Electric equipment shall be frequently examined, tested, and properly maintained by a qualified person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept.","occurrenceCount":1}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518424","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}