{"data":{"schemaVersion":"realm.mine-profile.v1","generatedAt":"2026-10-13T11:26:59.401Z","identity":{"mine_id":"1518390","name":"Johns Creek Energy","status":"Abandoned and Sealed","status_date":"2014-07-08","mine_type":"Surface","coal_metal":"C","commodity":"Coal (Bituminous)","state":"KY","county":"Pike","nearest_town":"Pikeville","operator_id":"P16149","operator_name":"Sidney Coal Company, Inc","controller_id":"0127923","controller_name":"Alpha Natural Resources Holdings, Inc","district":"C05","office":"Pikeville KY Field Office","employees":0,"latitude":37.614722,"longitude":-82.536111},"coverage":{"contributingSources":16,"registeredSources":20,"sourceRows":2148},"relationships":{"schemaVersion":"realm.temporal-relationships.v1","temporalSemantics":{"validTime":{"granularity":"date","bounds":"inclusive","nullStart":"start date not published in the upstream history row","nullEnd":"open-ended in the upstream history row; not independent proof of present control"},"transactionTime":{"observedAt":"2026-10-13T11:19:05.459773+00:00","meaning":"time the checksum-addressed MDRS artifacts were observed by the PostgreSQL ingestion"},"derivation":{"controllerControlsOperator":"intersection of controller and operator valid-time intervals evidenced through this mine","currentIdentity":"current controller and operator are asserted only by the MDRS Mines snapshot"}},"current":{"mine":{"type":"mine","id":"1518390","name":"Johns Creek Energy"},"operator":{"type":"operator","id":"P16149","name":"Sidney Coal Company, Inc"},"controller":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"source":{"datasetId":"msha-mines","observedAt":"2026-10-13T11:19:05.459773+00:00"}},"edges":[{"type":"controller_controls_mine","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"mine","id":"1518390","name":"Johns Creek Energy"},"validFrom":"1984-10-04","validTo":"2011-05-31","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|C02508|1984-10-04|2011-05-31"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"mine","id":"1518390","name":"Johns Creek Energy"},"validFrom":"1988-09-28","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|C13562|1988-09-28|"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"object":{"type":"mine","id":"1518390","name":"Johns Creek Energy"},"validFrom":"2001-06-01","validTo":"2001-07-11","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|P19831|2001-06-01|2001-07-11"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C13562","name":"James River Coal Company"},"object":{"type":"operator","id":"P19831","name":"Mc Coy Elkhorn Coal Corp"},"validFrom":"2001-06-01","validTo":"2001-07-11","current":false,"derived":true,"evidenceMineId":"1518390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|P19831|2001-06-01|C13562|1988-09-28|90341"}},{"type":"operator_operates_mine","subject":{"type":"operator","id":"P16149","name":"Sidney Coal Company, Inc"},"object":{"type":"mine","id":"1518390","name":"Johns Creek Energy"},"validFrom":"2001-07-12","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|P16149|2001-07-12|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"C02508","name":"Massey Energy Company"},"object":{"type":"operator","id":"P16149","name":"Sidney Coal Company, Inc"},"validFrom":"2001-07-12","validTo":"2011-05-31","current":false,"derived":true,"evidenceMineId":"1518390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|P16149|2001-07-12|C02508|1984-10-04|59205"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"mine","id":"1518390","name":"Johns Creek Energy"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|0041211|2011-06-01|2016-07-25"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0041211","name":"Alpha Natural Resources, Inc."},"object":{"type":"operator","id":"P16149","name":"Sidney Coal Company, Inc"},"validFrom":"2011-06-01","validTo":"2016-07-25","current":false,"derived":true,"evidenceMineId":"1518390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|P16149|2001-07-12|0041211|2011-06-01|1882"}},{"type":"controller_controls_mine","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"mine","id":"1518390","name":"Johns Creek Energy"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|0127923|2016-07-26|"}},{"type":"controller_controls_operator","subject":{"type":"controller","id":"0127923","name":"Alpha Natural Resources Holdings, Inc"},"object":{"type":"operator","id":"P16149","name":"Sidney Coal Company, Inc"},"validFrom":"2016-07-26","validTo":null,"current":true,"derived":true,"evidenceMineId":"1518390","intervalAnomaly":false,"source":{"datasetId":"msha-controller-operator-history","observedAt":"2026-10-13T11:19:05.459773+00:00","recordKey":"1518390|P16149|2001-07-12|0127923|2016-07-26|25417"}}],"coverage":{"historyRecords":4,"edgeCount":10,"intervalAnomalies":0,"sourceDatasetId":"msha-controller-operator-history"}},"sources":[{"id":"msha-accidents","name":"Accident, Injuries, and Illnesses","domains":["safety","contractors"],"products":["incident trends","severity rates","equipment patterns","peer denominators"],"rowCount":23,"firstDate":"2001-09-27","lastDate":"2005-06-06","metrics":{"daysLost":1226,"injuries":20,"fatalities":0,"recentRows":0,"restrictedDays":0,"contractorRecords":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"22977","DOCUMENT_NO":"220051590036","ACCIDENT_DT":"06/06/2005","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"OTHER","ACCIDENT_TYPE":"Absorption of radiations, caustics, toxic and noxious substances","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"TIMBERS HAD BEEN LOADED WITH A FORK LIFT & TAKEN UNDERGROUND. THE EMPLOYEE WAS IN THE PROCESS OF SETTING TIMBERS; HE TOOK OFF HIS GLOVE TO GET A PIECE OF CHALK OUT OF HIS POCKET & PLACED HIS HAND ON THE TIMBERS. A SNAKE (COPPER-HEAD) HAD BEEN BROUGHT INSIDE WITH THE TIMBERS & THE SNAKE BIT THE EE ON THE LEFT INDEX FINGER. THE EE WAS TAKEN TO A MEDICAL CENTER FOR TREATMENT.","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"27341","DOCUMENT_NO":"220042470025","ACCIDENT_DT":"08/29/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"ROOF FALL OCCURED IN NO. 2 BELT RETURN, 6 ENTRY, 2 BREAKS INBY SPAD NO.1337. FALL WAS 19'W X 50'L X 5'H. INSPECTOR ASSISTED WITH THE INVESTIGATION.","sourceDate":"2004-08-29"},{"SOURCE_ROW_NUMBER":"203565","DOCUMENT_NO":"220042380026","ACCIDENT_DT":"08/23/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"IN THE #4 BELT ENTRY, ON THE #2 BELT, 18' OUTBY SPAD #1337, A FALL OCCURRED ABOUT 5:15 P.M. MEASURING APPROXIMATELY 9' W X 60' L X 7' H.","sourceDate":"2004-08-23"},{"SOURCE_ROW_NUMBER":"27340","DOCUMENT_NO":"220042360101","ACCIDENT_DT":"08/19/2004","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Laborer, Bull gang,  Parts runner, Roustabout, Roof trimmer/scaler","NO_INJURIES":"1","DAYS_LOST":"0","NARRATIVE":"DURING A BELT SPLICING OPERATION, THE EE'S KNIFE SLIPPED & CUT HIS RT. UPPER LEG. HE WAS TAKEN TO THE E.R., WHERE STITCHES WERE USED TO CLOSE THE WOUND.","sourceDate":"2004-08-19"},{"SOURCE_ROW_NUMBER":"40128","DOCUMENT_NO":"220041400016","ACCIDENT_DT":"05/13/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Roof bolter, Rock bolter,  Pinner, Mobile roof support operator (MRS)","NO_INJURIES":"1","DAYS_LOST":"45","NARRATIVE":"AS EMPLOYEE WAS LIFTING THE MINER CABLE HE DEVELOPED PAIN IN HIS BACK. HE IS PRESENTLY WAITING FOR A MRI.","sourceDate":"2004-05-13"},{"SOURCE_ROW_NUMBER":"91662","DOCUMENT_NO":"220041840067","ACCIDENT_DT":"04/19/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Over-exertion in wielding or throwing objects","OCCUPATION":"Beltman, Conveyor man,  Conveyor belt worker, Mobile bridge carrierman, Feeder operator, Conveyor rider","NO_INJURIES":"1","DAYS_LOST":"37","NARRATIVE":"Ee injured his right shoulder while busting a rock (2' x 2 1/2' x 3\") which was fouled in the feeder.","sourceDate":"2004-04-19"},{"SOURCE_ROW_NUMBER":"95913","DOCUMENT_NO":"220040840011","ACCIDENT_DT":"03/23/2004","DEGREE_INJURY":"ACCIDENT ONLY","CLASSIFICATION":"FALL OF ROOF OR BACK","ACCIDENT_TYPE":"Accident type, without injuries","OCCUPATION":"NO VALUE FOUND","NO_INJURIES":"0","DAYS_LOST":"0","NARRATIVE":"A roof fall occurred in one of the two intake air courses 3000\" from the active working section. The fall was 1 break long 18'wide and 4'thick. The fall did not impede travel or impair ventilation. The location of the fall was 60'inby SS1330.","sourceDate":"2004-03-23"},{"SOURCE_ROW_NUMBER":"113143","DOCUMENT_NO":"220040790037","ACCIDENT_DT":"03/02/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion NEC","OCCUPATION":"Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss","NO_INJURIES":"1","DAYS_LOST":"262","NARRATIVE":"MEMBER BENT OVER TO MOVE CABLES FROM #5 ENTRY WHEN HE FELT PAIN IN LOWER BACK. HE DID NOT START MISSING WORK UNTIL MARCH 5TH, 2004.","sourceDate":"2004-03-02"},{"SOURCE_ROW_NUMBER":"190629","DOCUMENT_NO":"220040290053","ACCIDENT_DT":"01/02/2004","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Over-exertion in lifting objects","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","DAYS_LOST":"1","NARRATIVE":"MEMBER WAS HELPING MOVE ROCK OFF OF TRACK AND EXPERIENCED PAIN N HIS LOWER BACK. HE WAS SEEN BY THE E.R. DOCTOR WHO INSTRUCTED HIM TO FOLLOW UP WITH HIS PERSONAL MEDICAL DOCTOR WHO WAS NOT AVA ILABLE UNTIL THE FOLLOWING MONDAY MORNING WHO RELEASED HIM TO WORK.","sourceDate":"2004-01-02"},{"SOURCE_ROW_NUMBER":"203564","DOCUMENT_NO":"220032270064","ACCIDENT_DT":"08/13/2003","DEGREE_INJURY":"DAYS AWAY FROM WORK ONLY","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Caught in, under or between a moving and a stationary object","OCCUPATION":"Trackman, Track worker, Track gang","NO_INJURIES":"1","DAYS_LOST":"8","NARRATIVE":"EE WAS INSTALLING TRACK. TRACK WAS RAISED WITH FORK LIFT. HE PRYING TRACK WITH SLATE BAR WHEN RAIL FELL OFF PINNING FINGER BETWEEN FLOOR AND SLATE BAR.","sourceDate":"2003-08-13"},{"SOURCE_ROW_NUMBER":"263880","DOCUMENT_NO":"220032300021","ACCIDENT_DT":"08/12/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDTOOLS (NONPOWERED)","ACCIDENT_TYPE":"Struck by... NEC","OCCUPATION":"Maintenance man, Mechanic,  Repair/Serviceman, Boilermaker, Fueler, Tire tech, Field service tech","NO_INJURIES":"1","NARRATIVE":"EE WAS DRIVING STEERING JACK PIN INTO PLACE WHEN A PIECE OF THE METAL STRUCK HIM IN THE ARM.","sourceDate":"2003-08-12"},{"SOURCE_ROW_NUMBER":"78900","DOCUMENT_NO":"220032300022","ACCIDENT_DT":"08/11/2003","DEGREE_INJURY":"NO DYS AWY FRM WRK,NO RSTR ACT","CLASSIFICATION":"HANDLING OF MATERIALS","ACCIDENT_TYPE":"Struck against stationary object","OCCUPATION":"Electrician, Lineman","NO_INJURIES":"1","NARRATIVE":"EE RECEIVED LACERATION TO RIGHT HAND LITTLE FINGER WHILE INSERTING SUCTION HOSE INTO HYD. OIL CAN. STITCHES REQUIRED.","sourceDate":"2003-08-11"}]},{"id":"msha-addresses","name":"Addresses of Record","domains":["identity","logistics"],"products":["entity resolution","address history","facility geocoding"],"rowCount":1,"firstDate":"2014-07-08","lastDate":"2014-07-08","metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-assessed-violations","name":"Assessed Violations","domains":["compliance","legal"],"products":["penalty lifecycle","paid and outstanding amounts","assessment aging"],"rowCount":236,"firstDate":"2001-07-09","lastDate":"2005-06-21","metrics":{"ss":81,"delinquent":209,"recentRows":0,"paidPenalty":35391,"proposedPenalty":39291,"currentAssessment":35391},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"958796","VIOLATION_NO":"7416888","ISSUE_DT":"06/21/2005","CFR_STANDARD_CD":"77.410(c)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"958795","VIOLATION_NO":"7416887","ISSUE_DT":"06/21/2005","CFR_STANDARD_CD":"75.1722","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"247.00","CURRENT_ASSESSMENT_AMT":"247.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"958794","VIOLATION_NO":"7416886","ISSUE_DT":"06/21/2005","CFR_STANDARD_CD":"75.333(e)(1)(ii)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"958793","VIOLATION_NO":"7416885","ISSUE_DT":"06/21/2005","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"958792","VIOLATION_NO":"7416884","ISSUE_DT":"06/21/2005","CFR_STANDARD_CD":"75.1202-1","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"958791","VIOLATION_NO":"7416883","ISSUE_DT":"06/06/2005","CFR_STANDARD_CD":"75.370(d)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"440.00","CURRENT_ASSESSMENT_AMT":"440.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"958790","VIOLATION_NO":"7416882","ISSUE_DT":"06/06/2005","CFR_STANDARD_CD":"75.333(d)(3)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"958789","VIOLATION_NO":"7416881","ISSUE_DT":"06/06/2005","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"Y","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"440.00","CURRENT_ASSESSMENT_AMT":"440.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"986841","VIOLATION_NO":"7415555","ISSUE_DT":"06/01/2005","CFR_STANDARD_CD":"75.370(a)(1)","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-06-01"},{"SOURCE_ROW_NUMBER":"984651","VIOLATION_NO":"7415807","ISSUE_DT":"05/05/2005","CFR_STANDARD_CD":"75.1502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-05"},{"SOURCE_ROW_NUMBER":"984650","VIOLATION_NO":"7415806","ISSUE_DT":"05/05/2005","CFR_STANDARD_CD":"75.1502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-05"},{"SOURCE_ROW_NUMBER":"984649","VIOLATION_NO":"7415805","ISSUE_DT":"05/05/2005","CFR_STANDARD_CD":"75.1502","SIG_SUB_IND":"N","CITATION_TYPE_CD":"Citation","PROPOSED_PENALTY_AMT":"60.00","CURRENT_ASSESSMENT_AMT":"60.00","ASSESS_CASE_STATUS_CD":"Closed","sourceDate":"2005-05-05"}]},{"id":"msha-civil-penalty-dockets-decisions","name":"Civil Penalty Dockets and Decisions","domains":["compliance","legal"],"products":["docket lineage","decision outcomes","citation packet precedent"],"rowCount":2,"firstDate":"2005-01-13","lastDate":"2005-01-13","metrics":{"appeals":0,"decisions":2,"recentRows":0,"decisionPenalty":5000,"originalPenalty":8900},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"473801","VIOLATION_NO":"7389880","DOCKET_NO":"KENT20030121","DECISION_DT":"01/13/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4500.00","DECISION_PENALTY_AMT":"2000.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2005-01-13"},{"SOURCE_ROW_NUMBER":"473255","VIOLATION_NO":"7392692","DOCKET_NO":"KENT20030121","DECISION_DT":"01/13/2005","DECISION_TYPE_CODE_DESC":"Settlement","ORIGINAL_PENALTY_AMT":"4400.00","DECISION_PENALTY_AMT":"3000.00","JUDGE_FIRST_NAME":"Jacqueline","JUDGE_LAST_NAME":"Bulluck","sourceDate":"2005-01-13"}]},{"id":"msha-coal-dust-samples","name":"Coal Dust Samples","domains":["health","safety"],"products":["respirable dust trends","CPDM coverage","void patterns","occupation exposure"],"rowCount":597,"firstDate":"2001-08-21","lastDate":"2005-05-10","metrics":{"recentRows":0,"cpdmSamples":0,"voidSamples":65,"validSamples":532,"maxConcentration":8.918,"concentrationTotal":298.262},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"1021962","CASS_NUM":"50781110","SMP_TAKEN_DT":"5/10/2005","CONC":".109","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-10"},{"SOURCE_ROW_NUMBER":"834551","CASS_NUM":"50781154","SMP_TAKEN_DT":"5/10/2005","CONC":".096","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"VOID SAMPLE","VOID_CD_DESC":"EXCESS SAMPLE","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-10"},{"SOURCE_ROW_NUMBER":"953643","CASS_NUM":"50781161","SMP_TAKEN_DT":"5/9/2005","CONC":".5","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-09"},{"SOURCE_ROW_NUMBER":"662180","CASS_NUM":"50781103","SMP_TAKEN_DT":"5/9/2005","CONC":".452","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-09"},{"SOURCE_ROW_NUMBER":"1304230","CASS_NUM":"50781132","SMP_TAKEN_DT":"5/6/2005","CONC":".461","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-06"},{"SOURCE_ROW_NUMBER":"946448","CASS_NUM":"50781146","SMP_TAKEN_DT":"5/6/2005","CONC":".468","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-06"},{"SOURCE_ROW_NUMBER":"747965","CASS_NUM":"50781136","SMP_TAKEN_DT":"5/5/2005","CONC":".953","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-05"},{"SOURCE_ROW_NUMBER":"481637","CASS_NUM":"50781169","SMP_TAKEN_DT":"5/5/2005","CONC":".856","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-05"},{"SOURCE_ROW_NUMBER":"1390386","CASS_NUM":"50781116","SMP_TAKEN_DT":"5/4/2005","CONC":"1.502","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-04"},{"SOURCE_ROW_NUMBER":"1059807","CASS_NUM":"50781145","SMP_TAKEN_DT":"5/4/2005","CONC":"1.627","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-04"},{"SOURCE_ROW_NUMBER":"1238233","CASS_NUM":"50781181","SMP_TAKEN_DT":"5/3/2005","CONC":".766","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-03"},{"SOURCE_ROW_NUMBER":"1052971","CASS_NUM":"50781105","SMP_TAKEN_DT":"5/3/2005","CONC":".743","SMP_TYPE_CD_DESC":"DESIGNATED OCCUPATION","SMP_USE_CD_DESC":"BIMONTHLY CYCLE/TRANSITION PERIOD SAMPLE","VOID_CD_DESC":"SAMPLE NOT VOIDED","OCC_CD_DESC":"CONTINUOUS MINER OPERATOR","DEVICE_TYPE_CD":"CMDPSU","sourceDate":"2005-05-03"}]},{"id":"msha-conferences","name":"Conferences","domains":["compliance","legal"],"products":["conference history","post-issuance changes","citation lifecycle"],"rowCount":5,"firstDate":"2002-05-06","lastDate":"2004-01-29","metrics":{"linkedIssuances":5},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-quarterly","name":"Contractor Employment and Production — Quarterly","domains":["contractors","production","safety"],"products":["contractor exposure denominator","productivity","presence windows"],"rowCount":633,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-contractor-production-yearly","name":"Contractor Employment and Production — Yearly","domains":["contractors","production","safety"],"products":["long-run contractor trend","annual denominator reconciliation"],"rowCount":105,"firstDate":null,"lastDate":null,"metrics":{"linkedContractors":5,"notMineAttributable":1},"periods":{},"recentRecords":[]},{"id":"msha-controller-operator-history","name":"Controller and Operator History","domains":["identity","compliance"],"products":["historical ownership attribution","operator transitions","valid-time joins"],"rowCount":4,"firstDate":"2001-06-01","lastDate":"2001-07-12","metrics":{"recentRows":0,"currentOperatorTenures":3,"completedOperatorTenures":1},"periods":{},"recentRecords":[]},{"id":"msha-inspections","name":"Inspections","domains":["safety","compliance"],"products":["inspection mix","on-site hours","event context","citation rate denominator"],"rowCount":129,"firstDate":"2001-07-09","lastDate":"2011-01-11","metrics":{"inspectors":165,"recentRows":0,"onSiteHours":1876.25,"inspectionHours":2604,"inspectionSamples":0},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"997615","EVENT_NO":"4195248","INSPECTION_BEGIN_DT":"01/11/2011","INSPECTION_END_DT":"01/11/2011","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2011-01-11"},{"SOURCE_ROW_NUMBER":"461546","EVENT_NO":"4195240","INSPECTION_BEGIN_DT":"10/07/2010","INSPECTION_END_DT":"10/07/2010","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.5","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2010-10-07"},{"SOURCE_ROW_NUMBER":"893640","EVENT_NO":"4195289","INSPECTION_BEGIN_DT":"09/29/2009","INSPECTION_END_DT":"09/29/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"4.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2009-09-29"},{"SOURCE_ROW_NUMBER":"805652","EVENT_NO":"4195283","INSPECTION_BEGIN_DT":"06/25/2009","INSPECTION_END_DT":"06/25/2009","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"2","SUM_TOTAL_INSP_HOURS":"3.5","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2009-06-25"},{"SOURCE_ROW_NUMBER":"591888","EVENT_NO":"4195215","INSPECTION_BEGIN_DT":"10/09/2008","INSPECTION_END_DT":"10/09/2008","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2","SUM_TOTAL_ON_SITE_HOURS":"1","sourceDate":"2008-10-09"},{"SOURCE_ROW_NUMBER":"634606","EVENT_NO":"4193148","INSPECTION_BEGIN_DT":"12/13/2007","INSPECTION_END_DT":"12/13/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"2.5","sourceDate":"2007-12-13"},{"SOURCE_ROW_NUMBER":"263700","EVENT_NO":"4194514","INSPECTION_BEGIN_DT":"09/26/2007","INSPECTION_END_DT":"09/26/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5","SUM_TOTAL_ON_SITE_HOURS":"3","sourceDate":"2007-09-26"},{"SOURCE_ROW_NUMBER":"382668","EVENT_NO":"4194503","INSPECTION_BEGIN_DT":"06/18/2007","INSPECTION_END_DT":"06/18/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"3","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2007-06-18"},{"SOURCE_ROW_NUMBER":"1020440","EVENT_NO":"4193518","INSPECTION_BEGIN_DT":"03/30/2007","INSPECTION_END_DT":"03/30/2007","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"2.5","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2007-03-30"},{"SOURCE_ROW_NUMBER":"273262","EVENT_NO":"4179184","INSPECTION_BEGIN_DT":"07/31/2006","INSPECTION_END_DT":"07/31/2006","ACTIVITY_CODE":"E16","ACTIVITY":"Spot Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"7","SUM_TOTAL_ON_SITE_HOURS":"5.5","sourceDate":"2006-07-31"},{"SOURCE_ROW_NUMBER":"632264","EVENT_NO":"4179239","INSPECTION_BEGIN_DT":"05/02/2006","INSPECTION_END_DT":"06/02/2006","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"5.25","SUM_TOTAL_ON_SITE_HOURS":"2","sourceDate":"2006-05-02"},{"SOURCE_ROW_NUMBER":"289150","EVENT_NO":"4179161","INSPECTION_BEGIN_DT":"10/03/2005","INSPECTION_END_DT":"11/28/2005","ACTIVITY_CODE":"E01","ACTIVITY":"Regular Safety and Health Inspection","NBR_INSPECTOR":"1","SUM_TOTAL_INSP_HOURS":"6","SUM_TOTAL_ON_SITE_HOURS":"1.5","sourceDate":"2005-10-03"}]},{"id":"msha-mine-production-quarterly","name":"Mine Employment and Production — Quarterly","domains":["production","safety","compliance"],"products":["production trend","employee hours","rate denominators","seasonality"],"rowCount":82,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2012-Q2":{"hours":0,"employees":0,"production":0},"2012-Q1":{"hours":0,"employees":0,"production":0},"2011-Q4":{"hours":0,"employees":0,"production":0},"2011-Q3":{"hours":0,"employees":0,"production":0},"2008-Q4":{"hours":0,"employees":0,"production":0},"2008-Q3":{"hours":0,"employees":0,"production":0},"2006-Q3":{"hours":0,"employees":0,"production":0},"2006-Q2":{"hours":0,"employees":0,"production":0},"2006-Q1":{"hours":0,"employees":0,"production":0},"2005-Q4":{"hours":0,"employees":0,"production":0},"2005-Q3":{"hours":0,"employees":0,"production":0},"2005-Q2":{"hours":24586,"employees":39,"production":135590}},"recentRecords":[]},{"id":"msha-mine-production-yearly","name":"Mine Employment and Production — Yearly","domains":["production","safety","compliance"],"products":["annual trend","backfill","quarterly reconciliation"],"rowCount":13,"firstDate":null,"lastDate":null,"metrics":{},"periods":{"2001":{"hours":46610,"employees":40,"production":224941},"2002":{"hours":111845,"employees":45,"production":543150},"2003":{"hours":92299,"employees":41,"production":436225},"2004":{"hours":100100,"employees":41,"production":337895},"2005":{"hours":49989,"employees":38,"production":268912}},"recentRecords":[]},{"id":"msha-mines","name":"Mines","domains":["identity","production","logistics"],"products":["mine identity","status","commodity","location","operator and controller"],"rowCount":1,"firstDate":null,"lastDate":null,"metrics":{},"periods":{},"recentRecords":[]},{"id":"msha-noise-samples","name":"Noise Samples","domains":["health","safety","equipment"],"products":["hearing exposure","machine and manufacturer patterns","occupation coverage"],"rowCount":23,"firstDate":"2001-09-26","lastDate":"2003-02-27","metrics":{"recentRows":0,"doseOver100":6,"actDoseTotal":2007,"pelDoseTotal":1537},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"75192","EVENT_NO":"4185200","SURVEY_DATE":"02/27/2003","OCCUPATION_CD_DESC":"SCOOP CAR OPERATOR","MACHINE_CD":"38","MANUFACTURER_CD":"119","ACT_DOSE_85":"84","PEL_DOSE_90":"51","SURVEY_TYPE":"F","sourceDate":"2003-02-27"},{"SOURCE_ROW_NUMBER":"75191","EVENT_NO":"4185200","SURVEY_DATE":"02/27/2003","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"66","PEL_DOSE_90":"33","SURVEY_TYPE":"F","sourceDate":"2003-02-27"},{"SOURCE_ROW_NUMBER":"75190","EVENT_NO":"4185200","SURVEY_DATE":"02/27/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"39","PEL_DOSE_90":"25","SURVEY_TYPE":"F","sourceDate":"2003-02-27"},{"SOURCE_ROW_NUMBER":"75189","EVENT_NO":"4185200","SURVEY_DATE":"02/27/2003","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"66","PEL_DOSE_90":"38","SURVEY_TYPE":"F","sourceDate":"2003-02-27"},{"SOURCE_ROW_NUMBER":"75188","EVENT_NO":"4185200","SURVEY_DATE":"02/27/2003","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"133","PEL_DOSE_90":"118","SURVEY_TYPE":"F","sourceDate":"2003-02-27"},{"SOURCE_ROW_NUMBER":"75177","EVENT_NO":"4164485","SURVEY_DATE":"09/24/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (RETURN SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"76","PEL_DOSE_90":"52","SURVEY_TYPE":"F","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"75176","EVENT_NO":"4164485","SURVEY_DATE":"09/24/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"63","PEL_DOSE_90":"36","SURVEY_TYPE":"F","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"75175","EVENT_NO":"4164485","SURVEY_DATE":"09/24/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"37","PEL_DOSE_90":"20","SURVEY_TYPE":"F","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"75174","EVENT_NO":"4164485","SURVEY_DATE":"09/24/2002","OCCUPATION_CD_DESC":"CONTINUOUS MINER OPERATOR","MACHINE_CD":"06","MANUFACTURER_CD":"058","ACT_DOSE_85":"76","PEL_DOSE_90":"62","SURVEY_TYPE":"F","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"75173","EVENT_NO":"4164485","SURVEY_DATE":"09/24/2002","OCCUPATION_CD_DESC":"ROOF BOLTER (TWIN HEAD) (INTAKE SIDE)","MACHINE_CD":"30","MANUFACTURER_CD":"039","ACT_DOSE_85":"45","PEL_DOSE_90":"20","SURVEY_TYPE":"F","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"75172","EVENT_NO":"4164485","SURVEY_DATE":"09/24/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"28","PEL_DOSE_90":"14","SURVEY_TYPE":"F","sourceDate":"2002-09-24"},{"SOURCE_ROW_NUMBER":"75171","EVENT_NO":"4164485","SURVEY_DATE":"09/24/2002","OCCUPATION_CD_DESC":"SHUTTLE CAR OPERATOR (STANDARD SIDE)","MACHINE_CD":"37","MANUFACTURER_CD":"058","ACT_DOSE_85":"57","PEL_DOSE_90":"35","SURVEY_TYPE":"F","sourceDate":"2002-09-24"}]},{"id":"msha-quartz-samples","name":"Quartz Samples — Coal","domains":["health","safety"],"products":["quartz exposure trends","occupation context","applicable-rule linkage"],"rowCount":42,"firstDate":"2001-10-23","lastDate":"2005-04-28","metrics":{"recentRows":0,"voidSamples":2,"maxQuartzPct":12.9,"validSamples":40,"quartzPctTotal":246.1},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"86373","CASSETTE_NO":"57582379","SAMPLE_DT":"04/28/2005","QUARTZ_PCT":"05.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-28"},{"SOURCE_ROW_NUMBER":"82772","CASSETTE_NO":"57582489","SAMPLE_DT":"04/27/2005","QUARTZ_PCT":"07.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-27"},{"SOURCE_ROW_NUMBER":"78052","CASSETTE_NO":"57582475","SAMPLE_DT":"04/27/2005","QUARTZ_PCT":"06.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-04-27"},{"SOURCE_ROW_NUMBER":"118790","CASSETTE_NO":"57581062","SAMPLE_DT":"02/11/2005","QUARTZ_PCT":"05.9","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-11"},{"SOURCE_ROW_NUMBER":"92797","CASSETTE_NO":"57581045","SAMPLE_DT":"02/11/2005","QUARTZ_PCT":"05.6","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-02-11"},{"SOURCE_ROW_NUMBER":"161236","CASSETTE_NO":"50747851","SAMPLE_DT":"01/27/2005","QUARTZ_PCT":"08.3","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-27"},{"SOURCE_ROW_NUMBER":"111462","CASSETTE_NO":"50747854","SAMPLE_DT":"01/27/2005","QUARTZ_PCT":"08.2","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-27"},{"SOURCE_ROW_NUMBER":"114075","CASSETTE_NO":"50755157","SAMPLE_DT":"01/14/2005","QUARTZ_PCT":"04.4","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-14"},{"SOURCE_ROW_NUMBER":"67020","CASSETTE_NO":"50755154","SAMPLE_DT":"01/14/2005","QUARTZ_PCT":"04.5","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-14"},{"SOURCE_ROW_NUMBER":"33862","CASSETTE_NO":"50755173","SAMPLE_DT":"01/14/2005","QUARTZ_PCT":"02.7","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2005-01-14"},{"SOURCE_ROW_NUMBER":"124825","CASSETTE_NO":"57581403","SAMPLE_DT":"12/28/2004","QUARTZ_PCT":"06.0","OCC_CODE_DESC":"CONTINUOUS MINER OPERATOR","SAMPLE_TYPE_DESC":"DESIGNATED OCCUPATION","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-12-28"},{"SOURCE_ROW_NUMBER":"109611","CASSETTE_NO":"57580901","SAMPLE_DT":"12/28/2004","QUARTZ_PCT":"06.9","OCC_CODE_DESC":"OCCUPATION CODE NOT FOUND","SAMPLE_TYPE_DESC":"DESIGNATED AREA","VOID_CD_DESC":"SAMPLE NOT VOIDED","sourceDate":"2004-12-28"}]},{"id":"msha-violations","name":"Violations","domains":["compliance","safety","legal"],"products":["citation and order record","condition text","Title 30 linkage","abatement patterns"],"rowCount":252,"firstDate":"2001-07-09","lastDate":"2005-06-21","metrics":{"ss":81,"amountDue":35391,"contested":2,"amountPaid":35391,"recentRows":0,"section104d":0,"unterminated":3,"proposedPenalty":39291},"periods":{},"recentRecords":[{"SOURCE_ROW_NUMBER":"996524","VIOLATION_NO":"7416888","VIOLATION_ISSUE_DT":"06/21/2005","SIG_SUB":"N","PART_SECTION":"77.410(c)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/22/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"996523","VIOLATION_NO":"7416887","VIOLATION_ISSUE_DT":"06/21/2005","SIG_SUB":"Y","PART_SECTION":"75.1722","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/22/2005","PROPOSED_PENALTY":"247","AMOUNT_DUE":"247","AMOUNT_PAID":"247","CONTESTED_IND":"N","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"996522","VIOLATION_NO":"7416886","VIOLATION_ISSUE_DT":"06/21/2005","SIG_SUB":"N","PART_SECTION":"75.333(e)(1)(ii)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"996521","VIOLATION_NO":"7416885","VIOLATION_ISSUE_DT":"06/21/2005","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"8","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"996520","VIOLATION_NO":"7416884","VIOLATION_ISSUE_DT":"06/21/2005","SIG_SUB":"N","PART_SECTION":"75.1202-1","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-06-21"},{"SOURCE_ROW_NUMBER":"996515","VIOLATION_NO":"7416542","VIOLATION_ISSUE_DT":"06/06/2005","CIT_ORD_SAFE":"Order","NO_AFFECTED":"0","TERMINATION_DT":"06/08/2005","CONTESTED_IND":"N","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"996514","VIOLATION_NO":"7416883","VIOLATION_ISSUE_DT":"06/06/2005","SIG_SUB":"Y","PART_SECTION":"75.370(d)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2005","PROPOSED_PENALTY":"440","AMOUNT_DUE":"440","AMOUNT_PAID":"440","CONTESTED_IND":"N","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"996513","VIOLATION_NO":"7416882","VIOLATION_ISSUE_DT":"06/06/2005","SIG_SUB":"N","PART_SECTION":"75.333(d)(3)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/06/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"996512","VIOLATION_NO":"7416881","VIOLATION_ISSUE_DT":"06/06/2005","SIG_SUB":"Y","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Reasonably","INJ_ILLNESS":"LostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/21/2005","PROPOSED_PENALTY":"440","AMOUNT_DUE":"440","AMOUNT_PAID":"440","CONTESTED_IND":"N","sourceDate":"2005-06-06"},{"SOURCE_ROW_NUMBER":"996511","VIOLATION_NO":"7415555","VIOLATION_ISSUE_DT":"06/01/2005","SIG_SUB":"N","PART_SECTION":"75.370(a)(1)","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"1","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"06/01/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-06-01"},{"SOURCE_ROW_NUMBER":"996471","VIOLATION_NO":"7415807","VIOLATION_ISSUE_DT":"05/05/2005","SIG_SUB":"N","PART_SECTION":"75.1502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"9","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-05-05"},{"SOURCE_ROW_NUMBER":"996470","VIOLATION_NO":"7415806","VIOLATION_ISSUE_DT":"05/05/2005","SIG_SUB":"N","PART_SECTION":"75.1502","CIT_ORD_SAFE":"Citation","LIKELIHOOD":"Unlikely","INJ_ILLNESS":"NoLostDays","NO_AFFECTED":"5","NEGLIGENCE":"ModNegligence","TERMINATION_DT":"05/12/2005","PROPOSED_PENALTY":"60","AMOUNT_DUE":"60","AMOUNT_PAID":"60","CONTESTED_IND":"N","sourceDate":"2005-05-05"}]}],"safety":{"href":"/api/v1/mines/1518390/safety","description":"Full-period safety series, top CFR sections and paginated activity. Requires PostgreSQL."},"silica":{"href":"/api/v1/mines/1518390/silica","description":"Dedicated silica records, measurements, sample status and trends. Defaults to the snapshot year; use year=all for history."},"externalContext":{"eia":null,"title30":{"snapshot":{"chapterCount":6,"featuredSectionCount":100,"latestAmendedOn":"2026-08-14","latestIssueDate":"2026-08-14","partCount":206,"sectionCount":5954,"upToDateAsOf":"2026-08-19"},"regulations":[{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 77.410","heading":"Mobile equipment; automatic warning devices.","id":"77.410","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-77/subpart-E/section-77.410","part":"77","partHeading":"PART 77—MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"E","subpartHeading":"Subpart E—Safeguards for Mechanical Equipment","text":"(a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except pickup trucks with an unobstructed rear view, shall be equipped with a warning device that—\n\n(1) Gives an audible alarm when the equipment is put in reverse; or\n\n(2) Uses infrared light, ultrasonic waves, radar, or other effective devices to detect objects or persons at the rear of the equipment, and sounds an audible alarm when a person or object is detected. This type of discriminating warning device shall—\n\n(i) Have a sensing area of a sufficient size that would allow endangered persons adequate time to get out of the danger zone.\n\n(ii) Give audible and visual alarms inside the operator's compartment and an audible alarm outside of the operator's compartment when a person or object is detected in the sensing area; and\n\n(iii) When the equipment is put in reverse, activate and give a one-time audible and visual alarm inside the operator's compartment and a one-time audible alarm outside the operator's compartment.\n\n(b) Alarms shall be audible above the surrounding noise levels.\n\n(c) Warning devices shall be maintained in functional condition.\n\n(d) An automatic reverse-activated strobe light may be substituted for an audible alarm when mobile equipment is operated at night.\n\n[54 FR 30517, July 20, 1989]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.1722","heading":"Mechanical equipment guards.","id":"75.1722","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-R/section-75.1722","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"R","subpartHeading":"Subpart R—Miscellaneous","text":"(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.\n\n(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.\n\n(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.\n\n[38 FR 4976, Feb. 23, 1973]","occurrenceCount":1},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.333","heading":"Ventilation controls.","id":"75.333","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.333","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a) For purposes of this section, “doors” include any door frames.\n\n(b) Permanent stoppings or other permanent ventilation control devices constructed after November 15, 1992, shall be built and maintained—\n\n(1) Between intake and return air courses, except temporary controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the room was developed including where continuous face haulage systems are used in such rooms. Unless otherwise approved in the ventilation plan, these stoppings or controls shall be maintained to and including the third connecting crosscut outby the working face;\n\n(2) To separate belt conveyor haulageways from return air courses, except where belt entries in areas of mines developed before March 30, 1970, are used as return air courses;\n\n(3) To separate belt conveyor haulageways from intake air courses when the air in the intake air courses is used to provide air to active working places. Temporary ventilation controls may be used in rooms that are 600 feet or less from the centerline of the entry from which the rooms were developed including where continuous face haulage systems are used in such rooms. When continuous face haulage systems are used, permanent stoppings or other permanent ventilation control devices shall be built and maintained to the outby most point of travel of the dolly or 600 feet from the point of deepest penetration in the conveyor belt entry, whichever distance is closer to the point of deepest penetration, to separate the continuous haulage entry from the intake entries;\n\n(4) To separate the primary escapeway from belt and trolley haulage entries, as required by § 75.380(g). For the purposes of § 75.380(g), the loading point for a continuous haulage system shall be the outby most point of travel of the dolly or 600 feet from the point of deepest penetration, whichever distance is less; and\n\n(5) In return air courses to direct air into adjacent worked-out areas.\n\n(c) Personnel doors shall be constructed of noncombustible material and shall be of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between air courses, and shall be installed as follows in permanent stoppings constructed after November 15, 1992:\n\n(1) The distance between personnel doors shall be no more than 300 feet in seam heights below 48 inches and 600 feet in seam heights 48 inches or higher.\n\n(2) The location of all personnel doors in stoppings along escapeways shall be clearly marked so that the doors may be easily identified by anyone traveling in the escapeway and in the entries on either side of the doors.\n\n(3) When not in use, personnel doors shall be closed.\n\n(4) An airlock shall be established where the air pressure differential between air courses creates a static force exceeding 125 pounds on closed personnel doors along escapeways.\n\n(d) Doors, other than personnel doors, constructed after November 15, 1992, that are used in lieu of permanent stoppings or to control ventilation within an air course shall be:\n\n(1) Made of noncombustible material or coated on all accessible surfaces with flame-retardant materials having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(2) Of sufficient strength to serve their intended purpose of maintaining separation and permitting travel between or within air courses or entries.\n\n(3) Installed in pairs to form an airlock. When an airlock is used, one side of the airlock shall remain closed. When not in use, both sides shall be closed.\n\n(e)(1)(i) Except as provided in paragraphs (e)(2), (3), and (4) of this section, all overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after June 10, 1996, shall be constructed in a traditionally accepted method and of materials that have been demonstrated to perform adequately or in a method and of materials that have been tested and shown to have a minimum strength equal to or greater than the traditionally accepted in-mine controls. Tests may be performed under ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction” (Section 12-Transverse Load-Specimen Vertical, load, only), or the operator may conduct comparative in-mine tests. In-mine tests shall be designed to demonstrate the comparative strength of the proposed construction and a traditionally accepted in-mine control. The publication ASTM E72-80, “Standard Methods of Conducting Strength Tests of Panels for Building Construction,” is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(ii) All overcasts, undercasts, shaft partitions, permanent stoppings, and regulators, installed after November 15, 1992, shall be constructed of noncombustible material. Materials that are suitable for the construction of overcasts, undercasts, shaft partitions, permanent stoppings, and regulators include concrete, concrete block, brick, cinder block, tile, or steel. No ventilation controls installed after November 15, 1992, shall be constructed of aluminum.\n\n(2) In anthracite mines, permanent stoppings may be constructed of overlapping layers of hardwood mine boards, if the stoppings are a minimum 2 inches thick.\n\n(3) When timbers are used to create permanent stoppings in heaving or caving areas, the stoppings shall be coated on all accessible surfaces with a flame-retardant material having a flame-spread index of 25 or less, as tested under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(4) In anthracite mines, doors and regulators may be constructed of overlapping layers of hardwood boards, if the doors, door frames, and regulators are a minimum 2 inches thick.\n\n(f) When sealants are applied to ventilation controls, the sealant shall have a flame-spread index of 25 or less under ASTM E162-87, “Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source.” This publication is incorporated by reference and may be inspected at any MSHA Coal Mine Safety and Health District Office, or at MSHA's Office of Standards, Regulations, and Variances, 200 Constitution Avenue NW, Washington, DC 20210; 202-693-9440; and at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. In addition, copies of the document can be purchased from the American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959; 610-832-9500; http://www.astm.org. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.\n\n(g) Before mining is discontinued in an entry or room that is advanced more than 20 feet from the inby rib, a crosscut shall be made or line brattice shall be installed and maintained to provide adequate ventilation. When conditions such as methane liberation warrant a distance less than 20 feet, the approved ventilation plan shall specify the location of such rooms or entries and the maximum distance they will be developed before a crosscut is made or line brattice is installed.\n\n(h) All ventilation controls, including seals, shall be maintained to serve the purpose for which they were built.\n\n[61 FR 9829, Mar. 11, 1996; 61 FR 20877, May 8, 1996; 61 FR 26442, May 28, 1996; 61 FR 29288, 29289, June 10, 1996, as amended at 67 FR 38386, June 4, 2002; 71 FR 16668, Apr. 3, 2006; 73 FR 80612, Dec. 31, 2008; 80 FR 52991, Sept. 2, 2015; 91 FR 9448, Feb. 26, 2026]","occurrenceCount":2},{"chapter":"I","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","citation":"30 CFR 75.370","heading":"Mine ventilation plan; submission and approval.","id":"75.370","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-D/section-75.370","part":"75","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subchapter":"O","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","subpart":"D","subpartHeading":"Subpart D—Ventilation","text":"(a)(1) The operator shall develop and follow a ventilation plan approved by the district manager. The plan shall be designed to control methane and respirable dust and shall be suitable to the conditions and mining system at the mine. The ventilation plan shall consist of two parts, the plan content as prescribed in § 75.371 and the ventilation map with information as prescribed in § 75.372. Only that portion of the map which contains information required under § 75.371 will be subject to approval by the district manager.\n\n(2) The proposed ventilation plan and any revision to the plan shall be submitted in writing to the district manager. When revisions to a ventilation plan are proposed, only the revised pages, maps, or sketches of the plan need to be submitted. When required in writing by the district manager, the operator shall submit a fully revised plan by consolidating the plan and all revisions in an orderly manner and by deleting all outdated material.\n\n(3) (i) The mine operator shall notify the representative of miners at least 5 days prior to submission of a mine ventilation plan and any revision to a mine ventilation plan. If requested, the mine operator shall provide a copy to the representative of miners at the time of notification. In the event of a situation requiring immediate action on a plan revision, notification of the revision shall be given, and if requested, a copy of the revision shall be provided, to the representative of miners by the operator at the time of submittal;\n\n(ii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be made available for inspection by the representative of miners; and\n\n(iii) A copy of the proposed ventilation plan, and a copy of any proposed revision, submitted for approval shall be posted on the mine bulletin board at the time of submittal. The proposed plan or proposed revision shall remain posted until it is approved, withdrawn or denied.\n\n(b) Following receipt of the proposed plan or proposed revision, the representative of miners may submit timely comments to the district manager, in writing, for consideration during the review process. A copy of these comments shall also be provided to the operator by the district manager upon request.\n\n(c) (1) The district manager will notify the operator in writing of the approval or denial of approval of a proposed ventilation plan or proposed revision. A copy of this notification will be sent to the representative of miners by the district manager.\n\n(2) If the district manager denies approval of a proposed plan or revision, the deficiencies of the plan or revision shall be specified in writing and the operator will be provided an opportunity to discuss the deficiencies with the district manager.\n\n(d) No proposed ventilation plan shall be implemented before it is approved by the district manager. Any intentional change to the ventilation system that alters the main air current or any split of the main air current in a manner that could materially affect the safety and health of the miners, or any change to the information required in § 75.371 shall be submitted to and approved by the district manager before implementation.\n\n(e) Before implementing an approved ventilation plan or a revision to a ventilation plan, persons affected by the revision shall be instructed by the operator in its provisions.\n\n(f) The approved ventilation plan and any revisions shall be—\n\n(1) Provided upon request to the representative of miners by the operator following notification of approval;\n\n(2) Made available for inspection by the representative of miners; and\n\n(3) Posted on the mine bulletin board within 1 working day following notification of approval. The approved plan and revisions shall remain posted on the bulletin board for the period that they are in effect.\n\n(g) The ventilation plan for each mine shall be reviewed every 6 months by an authorized representative of the Secretary to assure that it is suitable to current conditions in the mine.","occurrenceCount":4},{"chapter":"I","heading":"Temporary notations, revisions, and supplements.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-M/section-75.1202-1","part":"75","subchapter":"O","subpart":"M","id":"75.1202-1","citation":"30 CFR 75.1202-1","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":1},{"chapter":"I","heading":"Mine emergency evacuation and firefighting program of instruction.","officialUrl":"https://www.ecfr.gov/current/title-30/chapter-I/subchapter-O/part-75/subpart-P/section-75.1502","part":"75","subchapter":"O","subpart":"P","id":"75.1502","citation":"30 CFR 75.1502","chapterHeading":"CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR","subchapterHeading":"SUBCHAPTER O—COAL MINE SAFETY AND HEALTH","partHeading":"PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES","subpartHeading":"","text":null,"occurrenceCount":2}],"fullCorpus":"/data/title30-sections.json"}}},"meta":{"representation":"json","mineId":"1518390","dataSource":"postgres","snapshotId":"2026-10-13T11:19:05.459773+00:00","completedAt":"2026-10-13T11:26:59.401Z","sourceCount":20,"totalRows":17906804}}